Loading...
HomeMy WebLinkAboutP_Elevations_191113_v1.pdfSUNSET HIGHLANDS MIXED USE VICINITY MAP:REGIONAL MAP:REGULATORY CODES 2019 RENTON MUNICIPAL CODE (RMC) 2015 INTERNATIONAL BUILDING CODE (IBC) INTERNATIONAL ENERGY CONSERVATION CODE INTERNATIONAL FIRE CODE INTERNATIONAL FUEL GAS CODE INTERNATIONAL MECHANICAL CODE UNIFORM PLUMBING CODE WASHINGTON STATE ENERGY CODE ICC / ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES NFPA 13, 14, 20, 70, 72 AMERICAN IRON & STEEL INSTITUTE (AISI), CURRENT EDITION ALL WORK SHALL CONFORM TO APPLICABLE BUILDING CODES AND ORDINANCES, AS MODIFIED FOR THIS BUILDING ON RECORD AT THE CITY OF RENTON. IN CASE OF CONFLICT WHERE THE METHODS OR STANDARDS OF INSTALLATION OF THE MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAW OR ORDINANCE SHALL GOVERN. NOTIFY ARCHITECT OF ALL CONFLICTS IN WRITING. PROJECT ADDRESS: A.P.N. / TAX / PARCEL ZONING DISTRICT: LOT SIZE: BUILDING COVERAGE: GROSS BUILDING AREA: TOTAL BUILDING STORIES: OCCUPANCIES: SETBACKS: FIRE SPRINKLER: OTHER ZONING INFO: PROJECT INFORMATION DEFERRED SUBMITTALS DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. ITEMS TO BE DEFERRED: 1. FIRE SPRINKLER MODIFICATION DESIGN 2. FIRE ALARM DESIGN PROJECT TEAM DIRECTORY 4409 NE SUNSET BLVD. RENTON, WA 98059 0323059093 CA - COMMERCIAL ARTERIAL 35,593 SQUARE FEET 7,708 SQUARE FEET (LOT COVERAGE: 21.7%) 31,227 SQUARE FEET 4 TOTAL (FLOOR 1 = COMMERCIAL & PARKING, FLOORS 2 -4 = RESIDENTIAL) OVERALL HEIGHT: 55' - 3", 60' - 0" ALLOWED BY CODE (MIXED USE) B - BUSINESS, S-1 - STORAGE, R-2 - RESIDENTIAL (AND R-2 AMENITIES) FRONT: 15' MIN AND 20' MAX. REAR: 0', 15' FROM STREAM BUFFER. SIDE: 0'. FULLY AUTOMATIC SPRINKLER SYSTEM SITE INCLUDES WETLANDS ON THE SOUTH SIDE OF THE PROPERTY. SETBACKS HAVE BEEN MET AND WETLANDS CONSULTANT IS BEING BROUGHT ON THE PROJECT. PROJECT DESCRIPTION ADF PROPERTIES, LLC 15007 WOODINVILLE REDMOND RD. #A WOODINVILLE, WA 98072 CONTACT: DALE FONK PHONE: EMAIL: dalefonk@cs.com ARCHITECT OWNER / OWNER'S REP WETLANDS ENGINEER JON GRAVES ARCHITECTS & PLANNERS, PLLC 3110 RUSTON WAY SUITE 'E' TACOMA, WASHINGTON 98402 CONTACT: BEN CHILDS PHONE: 253.272.4214 EMAIL: bchilds@jgarchs.com SEWELL WETLANDS CONSULTING INC. 27641 COVINGTON WAY SE # 2 COVINGTON, WA, 98042 CONTACT: ED SEWELL PHONE: (253) 859-0515 EMAIL: ESEWALL@SEWALLWC.COM PROJECT LOCATION ADDRESS PROJECT LOCATION ADDRESS TRAFFIC ENGINEER HEATH TRAFFIC 2214 TACOMA ROAD PUYALLUP WA CONTACT: MARGARET NORRIS PHONE: (253) 770-1401 EMAIL: MNORRIS@HEATHTRAFFIC.COM CIVIL ENGINEER AHBL, INC 2215 N 30TH ST TACOMA, WA 98403 CONTACT: SCOTT KAUL PHONE: (253) 284-9645 EMAIL: skaul@ahbl.com STRUCTURAL ENGINEER AHBL, INC 2215 N 30TH ST TACOMA, WA 98403 CONTACT: ANDY PFLUEGER PHONE: (253) 284-0222 EMAIL: apflueger@ahbl.com MECHANICAL ENGINEER BIDDER DESIGN PLUMBING ENGINEER BIDDER DESIGN LANDSCAPE ARCHITECT LAUCHLIN BETHUNE 24813 247TH Pl SE MAPLE VALLEY, WA 98038 CONTACT: LAUCHLIN BETHUNE PHONE: (425) 432-9877 EMAIL: LAUCH@BETHUNEASSOCIATES.COM NTSNTS A NEW MIXED USE BUILDING OF APPROXIMATELY 31,227 SQUARE FEET. PARKING UNDER 3 FLOORS OF RESIDENTIAL APARTMENTS, JOINED WITH A COMMERCIAL SPACE UNDER AMENITY SPACE FOR THE ADJACENT RESIDENTIAL. LEVEL 1 CONTAINS 5 UNITS WITH AMENITY SPACE, LEVEL 2 CONTAINS 6 UNITS WITH LARGER AMENITY SPACE, LEVEL 3 CONTAINS 5 UNITS WITH AMENITY SPACE. THE BUILDING IS PODIUM CONSTRUCTION, WITH A PT SLAB BELOW STICK FRAMING. SEPERATE PERMIT SUBMITTALS WILL BE MADE FOR STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING SCOPES. FIRE ALARM AND FIRE SPRINKLER DESIGN SHALL BE SUBMITTED AS A DEFERRED SUBMITTAL. ELECTRICAL ENGINEER BIDDER DESIGN REUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS INSTRUMENTS OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF JGAP AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF JGAP.JON GRAVES ARCHITECTS & PLANNERS3110 RUSTON WAY, SUITE E TACOMA, WA 98402(253) 272-4214Sheet: COPYRIGHT, 2019 BY JON GRAVES ARCHITECTS AND PLANNERSPROJECT NUMBER:PM:-NOT FORCONSTRUCTION--CHECKED-11/1/2019 12:06:00 PM BIM 360://1911 Renton Mixed Use/1911 Renton Mixed Use.rvtSUNSET HIGHLANDS MIXED USE4409 NE SUNSET BLVD.RENTON, WA 98059TGSITE PLAN REVIEW - 11/01/19COVER SHEET1911AG100BC#DESCRIPTIONDATE 1ST FLOOR-COMMERCIAL & GARAGE 100' -0" 2ND FLOOR 110' -0" 3RD FLOOR 120' -0" 4TH FLOOR 130' -0" ROOF 140' -0" ABIHFGCED 10' - 0" 10' - 0" 10' - 0" 10' - 0" 12' - 3" PS2 SF5 SF6 SF6 SF6 SF6 SF7 BR-01 HB-01 HB-02 HB-01 CONC-01 HB-02 1ST FLOOR-COMMERCIAL & GARAGE 100' -0" 1 1ST FLOOR-GARAGE 97' -0" 2ND FLOOR 110' -0" 3RD FLOOR 120' -0" 4TH FLOOR 130' -0" ROOF 140' -0" 23469111278510 12' - 3"10' - 0"10' - 0"10' - 0"10' - 0"3' - 0"W5 W6W4 W3 W4W5W5 W6 W4 W4 W5 W5 W5 W6 W6 W4W4 W4W4 W4 W3 W5 SF1 SF1 SF1 SF2 PS1 2 E1 E1 E1E1 E1 E1 E5E5E5E5E5E5E5E5 SF3 SF4 19 17 BR-01 WD-01CONC-01HB-01CMTL-01CMTL-01HB-02CMTL-01HB-01 W5 W5W5 W5 W5W7W5 W5 W7 W7W5 SF55 ELEVATION SHEET NOTES 1. SEE ALL DRAWINGS FOR CALLOUTS IN COMMON. THE DRAWINGS DO NOT ANNOTATE ALL OCCURRENCES OF ELEMENTS FOR CONSTRUCTION. SUFFICIENT INFORMATION HAS BEEN PROVIDED TO PRECISELY CONSTRUCT THE PROJECT. IT IS THE CONTRACTOS RESPONSIBILITY TO COORDINATE THE ARCHITECTS DESIGN INTENT IN AREAS THAT ARE NOT FULLY DETAILED. 2. FOR INFORMATION REGARDING THE MAXIMUM BUILDING HEIGHT DATUM, AS APPLICABLE, REFER TO THE LONGITUDINAL BUILDING SECTIONS TAKEN FROM THE EAST TO THE WEST. THESE SECTIONS BEST ILLUSTRATE THE PLANE THAT ESTABLISHES THE MAXIMUM HEIGHT DATUM. 3. REFER TO ELEVATION KEYNOTES ON THIS SHEET FOR CALLOUT INFORMATION. 4. SEE SHEET AX.X FOR EXTERIOR PAINT COLORS. 5. ANY AND ALL PRE-FINISHED GUTTERS, METAL FLASHING, DOWNSPOUTS SHALL BE FINISHED W/ COLORS AS CONFIRMED AND SELECTED BY THE ARCHITECT FROM MANUFACTURER STANDARD COLOR CHART. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROVISION OF SUBMITTING SHOP DRAWINGS OR SKETCHES (SK'S) TO CONFIRM APPLICABLE PRE-FINISHED METAL PRODUCTS & ASSIGNED COLORS. 7. WHERE PRODUCTS ARE NOT IDENTIFIED AS PRE-FINISHED, PRODUCTS SHALL BE FIELD AND OR SHOP-PAINTED UTILIZING ARCHITECT APPROVED MANUFACTURERS AND COLORS. 8. WHERE SEALANTS ARE USED AND EXPOSED, SUCH PRODUCTS AND COLOR OPTIONS SHALL BE PRE- APPROVED BY THE ARCHITECT. SEALANTS USED SHALL BE COMPLIANT W/ THE 2015 WASHINGTON STATE ENERGY CODE. REUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS INSTRUMENTS OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF JGAP AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF JGAP.JON GRAVES ARCHITECTS & PLANNERS3110 RUSTON WAY, SUITE E TACOMA, WA 98402(253) 272-4214Sheet: COPYRIGHT, 2019 BY JON GRAVES ARCHITECTS AND PLANNERSPROJECT NUMBER:PM:-NOT FORCONSTRUCTION--CHECKED-11/1/2019 11:12:38 AM BIM 360://1911 Renton Mixed Use/1911 Renton Mixed Use.rvtSUNSET HIGHLANDS MIXED USE4409 NE SUNSET BLVD.RENTON, WA 98059TGSITE PLAN REVIEW - 11/01/19EXTERIOR ELEVATIONS1911A200BC1/8" = 1'-0" NORTH ELEVATION1 1/8" = 1'-0" EAST ELEVATION2 EXTERIOR ELEVATION SHEET NOTES 0'4'8'16'32' Key Value Keynote Text #DESCRIPTIONDATE 1ST FLOOR-COMMERCIAL & GARAGE 100' -0" 1ST FLOOR-GARAGE 97' -0" 2ND FLOOR 110' -0" 3RD FLOOR 120' -0" 4TH FLOOR 130' -0" ROOF 140' -0" A B IHFGCED 12' - 3"10' - 0"10' - 0"10' - 0"10' - 0"3' - 0"W7 W6 W7 W7 W9 W9 W9 2 HB-01 CONC-01 CMTL-01 MTL-01 W5W7W5 W5W7W5 W5 W7 W5 W5 W7 W5 W5 W7 W5 1ST FLOOR-COMMERCIAL & GARAGE 100' -0" 1 1ST FLOOR-GARAGE 97' -0" 2ND FLOOR 110' -0" 3RD FLOOR 120' -0" 4TH FLOOR 130' -0" ROOF 140' -0" 2 3 4 6 9 11 1278510 12' - 3"10' - 0"10' - 0"10' - 0"10' - 0"3' - 0"SF8 SF9 SF10 SF11 W6 W5 W4W5W5W4 W4 W4 W5 W5 W5 W5 W4 W4 W5 E2 E3 E4 E1 E1 E1 E1 E1 E1 SF13 E5 E5 E5 E5 E5 E5 E5 E5 2 19 17 SF7 W5 W7 W5 W5 W7 W5 CMTL-01 HB-01 CONC-01 HB-02 CMTL-01HB-01 ELEVATION SHEET NOTES 1. SEE ALL DRAWINGS FOR CALLOUTS IN COMMON. THE DRAWINGS DO NOT ANNOTATE ALL OCCURRENCES OF ELEMENTS FOR CONSTRUCTION. SUFFICIENT INFORMATION HAS BEEN PROVIDED TO PRECISELY CONSTRUCT THE PROJECT. IT IS THE CONTRACTOS RESPONSIBILITY TO COORDINATE THE ARCHITECTS DESIGN INTENT IN AREAS THAT ARE NOT FULLY DETAILED. 2. FOR INFORMATION REGARDING THE MAXIMUM BUILDING HEIGHT DATUM, AS APPLICABLE, REFER TO THE LONGITUDINAL BUILDING SECTIONS TAKEN FROM THE EAST TO THE WEST. THESE SECTIONS BEST ILLUSTRATE THE PLANE THAT ESTABLISHES THE MAXIMUM HEIGHT DATUM. 3. REFER TO ELEVATION KEYNOTES ON THIS SHEET FOR CALLOUT INFORMATION. 4. SEE SHEET AX.X FOR EXTERIOR PAINT COLORS. 5. ANY AND ALL PRE-FINISHED GUTTERS, METAL FLASHING, DOWNSPOUTS SHALL BE FINISHED W/ COLORS AS CONFIRMED AND SELECTED BY THE ARCHITECT FROM MANUFACTURER STANDARD COLOR CHART. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROVISION OF SUBMITTING SHOP DRAWINGS OR SKETCHES (SK'S) TO CONFIRM APPLICABLE PRE-FINISHED METAL PRODUCTS & ASSIGNED COLORS. 7. WHERE PRODUCTS ARE NOT IDENTIFIED AS PRE-FINISHED, PRODUCTS SHALL BE FIELD AND OR SHOP-PAINTED UTILIZING ARCHITECT APPROVED MANUFACTURERS AND COLORS. 8. WHERE SEALANTS ARE USED AND EXPOSED, SUCH PRODUCTS AND COLOR OPTIONS SHALL BE PRE- APPROVED BY THE ARCHITECT. SEALANTS USED SHALL BE COMPLIANT W/ THE 2015 WASHINGTON STATE ENERGY CODE. REUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS INSTRUMENTS OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF JGAP AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF JGAP.JON GRAVES ARCHITECTS & PLANNERS3110 RUSTON WAY, SUITE E TACOMA, WA 98402(253) 272-4214Sheet: COPYRIGHT, 2019 BY JON GRAVES ARCHITECTS AND PLANNERSPROJECT NUMBER:PM:-NOT FORCONSTRUCTION--CHECKED-11/1/2019 11:12:53 AM BIM 360://1911 Renton Mixed Use/1911 Renton Mixed Use.rvtSUNSET HIGHLANDS MIXED USE4409 NE SUNSET BLVD.RENTON, WA 98059TGSITE PLAN REVIEW - 11/01/19EXTERIOR ELEVATIONS1911A201BC1/8" = 1'-0" SOUTH ELEVATION1 1/8" = 1'-0" WEST ELEVATION2 0'4'8'16'32' Key Value Keynote Text EXTERIOR ELEVATION SHEET NOTES #DESCRIPTIONDATE SF6 SF6 SF6 SF6 SF5 PS2 SF7 1ST FLOOR-COMMERCIAL & GARAGE 100' -0" 2ND FLOOR 110' -0" 3RD FLOOR 120' -0" 4TH FLOOR 130' -0" ROOF 140' -0" 2.22.1 19 SF9 SF8 1ST FLOOR-COMMERCIAL & GARAGE 100' -0" 2ND FLOOR 110' -0" 3RD FLOOR 120' -0" 4TH FLOOR 130' -0" ROOF 140' -0" 2.3 2.2 2.1 19 PS1 2' - 5 3/4"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0" 2' - 5 1/4"2' - 5 1/4" EQEQ SF55 1ST FLOOR-COMMERCIAL & GARAGE 100' -0" 2ND FLOOR 110' -0" 3RD FLOOR 120' -0" 4TH FLOOR 130' -0" ROOF 140' -0" IH I H W6 W6 W6 1ST FLOOR-COMMERCIAL & GARAGE 100' -0" 1ST FLOOR-GARAGE 97' -0" 2ND FLOOR 110' -0" 3RD FLOOR 120' -0" 4TH FLOOR 130' -0" ROOF 140' -0" ELEVATION SHEET NOTES 1. SEE ALL DRAWINGS FOR CALLOUTS IN COMMON. THE DRAWINGS DO NOT ANNOTATE ALL OCCURRENCES OF ELEMENTS FOR CONSTRUCTION. SUFFICIENT INFORMATION HAS BEEN PROVIDED TO PRECISELY CONSTRUCT THE PROJECT. IT IS THE CONTRACTOS RESPONSIBILITY TO COORDINATE THE ARCHITECTS DESIGN INTENT IN AREAS THAT ARE NOT FULLY DETAILED. 2. FOR INFORMATION REGARDING THE MAXIMUM BUILDING HEIGHT DATUM, AS APPLICABLE, REFER TO THE LONGITUDINAL BUILDING SECTIONS TAKEN FROM THE EAST TO THE WEST. THESE SECTIONS BEST ILLUSTRATE THE PLANE THAT ESTABLISHES THE MAXIMUM HEIGHT DATUM. 3. REFER TO ELEVATION KEYNOTES ON THIS SHEET FOR CALLOUT INFORMATION. 4. SEE SHEET AX.X FOR EXTERIOR PAINT COLORS. 5. ANY AND ALL PRE-FINISHED GUTTERS, METAL FLASHING, DOWNSPOUTS SHALL BE FINISHED W/ COLORS AS CONFIRMED AND SELECTED BY THE ARCHITECT FROM MANUFACTURER STANDARD COLOR CHART. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROVISION OF SUBMITTING SHOP DRAWINGS OR SKETCHES (SK'S) TO CONFIRM APPLICABLE PRE-FINISHED METAL PRODUCTS & ASSIGNED COLORS. 7. WHERE PRODUCTS ARE NOT IDENTIFIED AS PRE-FINISHED, PRODUCTS SHALL BE FIELD AND OR SHOP-PAINTED UTILIZING ARCHITECT APPROVED MANUFACTURERS AND COLORS. 8. WHERE SEALANTS ARE USED AND EXPOSED, SUCH PRODUCTS AND COLOR OPTIONS SHALL BE PRE- APPROVED BY THE ARCHITECT. SEALANTS USED SHALL BE COMPLIANT W/ THE 2015 WASHINGTON STATE ENERGY CODE. REUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS INSTRUMENTS OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF JGAP AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF JGAP.JON GRAVES ARCHITECTS & PLANNERS3110 RUSTON WAY, SUITE E TACOMA, WA 98402(253) 272-4214Sheet: COPYRIGHT, 2019 BY JON GRAVES ARCHITECTS AND PLANNERSPROJECT NUMBER:PM:-NOT FORCONSTRUCTION--CHECKED-11/1/2019 11:12:56 AM BIM 360://1911 Renton Mixed Use/1911 Renton Mixed Use.rvtSUNSET HIGHLANDS MIXED USE4409 NE SUNSET BLVD.RENTON, WA 98059TGSITE PLAN REVIEW - 11/01/19EXTERIOR ELEVATIONS1911A202BC1/8" = 1'-0" NORTH FRONT FACADE3 1/8" = 1'-0" WEST FACADE ENTRANCE4 1/8" = 1'-0" EAST FACADE ENTRANCE5 1/8" = 1'-0" EAST - BUMP OUT A1 1/8" = 1'-0" EAST - BUMP OUT B2 1/8" = 1'-0" EAST - BUMP OUT C6 1/8" = 1'-0" EAST - BUMP OUT D7 1/8" = 1'-0" EAST - BUMP OUT E8 1/8" = 1'-0" EAST - BUMP OUT F9 Key Value Keynote Text EXTERIOR ELEVATION SHEET NOTES 0'4'8'16'32'#DESCRIPTIONDATE 1ST FLOOR-COMMERCIAL & GARAGE 100' -0" 1ST FLOOR-GARAGE 97' -0" 2ND FLOOR 110' -0" 3RD FLOOR 120' -0" 4TH FLOOR 130' -0" ROOF 140' -0" A B WD-01 AB W6 W6 W6 1ST FLOOR-COMMERCIAL & GARAGE 100' -0" 1ST FLOOR-GARAGE 97' -0" 2ND FLOOR 110' -0" 3RD FLOOR 120' -0" 4TH FLOOR 130' -0" ROOF 140' -0" ELEVATION SHEET NOTES 1. SEE ALL DRAWINGS FOR CALLOUTS IN COMMON. THE DRAWINGS DO NOT ANNOTATE ALL OCCURRENCES OF ELEMENTS FOR CONSTRUCTION. SUFFICIENT INFORMATION HAS BEEN PROVIDED TO PRECISELY CONSTRUCT THE PROJECT. IT IS THE CONTRACTOS RESPONSIBILITY TO COORDINATE THE ARCHITECTS DESIGN INTENT IN AREAS THAT ARE NOT FULLY DETAILED. 2. FOR INFORMATION REGARDING THE MAXIMUM BUILDING HEIGHT DATUM, AS APPLICABLE, REFER TO THE LONGITUDINAL BUILDING SECTIONS TAKEN FROM THE EAST TO THE WEST. THESE SECTIONS BEST ILLUSTRATE THE PLANE THAT ESTABLISHES THE MAXIMUM HEIGHT DATUM. 3. REFER TO ELEVATION KEYNOTES ON THIS SHEET FOR CALLOUT INFORMATION. 4. SEE SHEET AX.X FOR EXTERIOR PAINT COLORS. 5. ANY AND ALL PRE-FINISHED GUTTERS, METAL FLASHING, DOWNSPOUTS SHALL BE FINISHED W/ COLORS AS CONFIRMED AND SELECTED BY THE ARCHITECT FROM MANUFACTURER STANDARD COLOR CHART. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROVISION OF SUBMITTING SHOP DRAWINGS OR SKETCHES (SK'S) TO CONFIRM APPLICABLE PRE-FINISHED METAL PRODUCTS & ASSIGNED COLORS. 7. WHERE PRODUCTS ARE NOT IDENTIFIED AS PRE-FINISHED, PRODUCTS SHALL BE FIELD AND OR SHOP-PAINTED UTILIZING ARCHITECT APPROVED MANUFACTURERS AND COLORS. 8. WHERE SEALANTS ARE USED AND EXPOSED, SUCH PRODUCTS AND COLOR OPTIONS SHALL BE PRE- APPROVED BY THE ARCHITECT. SEALANTS USED SHALL BE COMPLIANT W/ THE 2015 WASHINGTON STATE ENERGY CODE. REUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS INSTRUMENTS OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF JGAP AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF JGAP.JON GRAVES ARCHITECTS & PLANNERS3110 RUSTON WAY, SUITE E TACOMA, WA 98402(253) 272-4214Sheet: COPYRIGHT, 2019 BY JON GRAVES ARCHITECTS AND PLANNERSPROJECT NUMBER:PM:-NOT FORCONSTRUCTION--CHECKED-11/1/2019 11:12:58 AM BIM 360://1911 Renton Mixed Use/1911 Renton Mixed Use.rvtSUNSET HIGHLANDS MIXED USE4409 NE SUNSET BLVD.RENTON, WA 98059TGSITE PLAN REVIEW - 11/01/19EXTERIOR ELEVATIONS1911A203BC1/8" = 1'-0" WEST - BUMP OUT A1 1/8" = 1'-0" WEST - BUMP OUT B2 1/8" = 1'-0" WEST - BUMP OUT C3 1/8" = 1'-0" WEST - BUMP OUT D4 1/8" = 1'-0" WEST - BUMP OUT E5 1/8" = 1'-0" WEST - BUMP OUT F6 Key Value Keynote Text EXTERIOR ELEVATION SHEET NOTES 0'4'8'16'32'#DESCRIPTIONDATE