HomeMy WebLinkAboutMFP19006232.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP19006232
IVR Number: 19006232
Permit Informaon
Permit Name:Comcast Cable Franchise Permit
Address/Locaon :11/19/2019Application Date:3223059065Parcel Number:17803 108TH AVE SE
Permit Type:12/03/2019Issue Date:Franchise
Permit Work Class:12/02/2020Expiration Date:Minor Utility
Job Number:JT320610Franchise Type:Cable
Description:Bore 1 2" from existing utility pole riser westward 18.5' onto private property. all substructures to have 36" of cover.
Restoration per City of Renton standards.
APPROVED WITH COMMENTS OR REDLINES
Contacts
Name Address PhoneTypeBilling
Comcast Cable Communication
Management & Comcast Cable
B: (215) 665-1700Applicant
Tom Donnelly
Comcast Business Communications
1701 Jfk Blvd, 32nd Floor
Philadelphia, PA 19103
B: (215) 286-7347
C: (215) 286-7557
Contact
Akisha Brown
Prince Telecom Inc
551A Mews Dr
New Castle, DE 19720
B: (302) 482-8893
C: (302) 482-8892
Contractor
Business License Number: 29850Electrical Contractor: PRINCTL834BF
Construction Contractor: PRINCTL862PS
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Laurie Dietz
Comcast - Billing
1701 John F. Kennedy Blvd.
Philadelphia, PA 19103
H: (425) 741-5733Specialized
Billing
X
General Condions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
This permit and plans must be posted at the job site at all times.
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Call 425.430.7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
MFP19006232Scott Warlick11/20/2019RESTORATION PER CITY OF RENTON STANDARDSHolly Powers12/3/2019
CITY OF RENTON
TRAFFIC CONTROL PLAN
PROJECT NAME: PERMIT#
CONSTRUCTION COMPANY: PHONE#:
CONTACT NAME: PHONE#:
ADDRESS: CELL#:
E-MAIL ADDRESS: FAX#:
PROJECT LOCATION: N/E/S/W OF:
WORK TIME: APPROVED BY:
WORK DATE: APPROVAL DATE:
OFFICE COPY T-
CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER
DEV. SERVICE, PLAN REVIEW B. BANNWARTH
POLICE CHARLES KARLEWICZ
FIRE FIRE MARSHALL FS #13
Permit Holder agrees to all the following:
• Comply with all traffic regulations of the City of Renton and the State of Washington.
• Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for
all street and lane closures, and the plan shall be performed in compliance with the Manual on
Uniform Traffic Control Devices.
• Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
• Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200
through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
• Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments,
including all costs of defense and attorney’s fees incurred in defending against same, arising from and
related to implementation of the approved traffic control plans including claims arising from towing of
private vehicles and the acts of the Permit Holder’s agents and employees.
• The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or
judgment, and in such event shall indemnify and hold harmless the City for any such claims paid,
including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim.
• In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder
will pay for legal counsel chosen by the City to defend against same.
• Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address
traffic or pedestrian safety or travel.
• By my signature herein, I acknowledge all the above requirements.
PRINT NAME: DATE:
SIGNATURE:
Michele Moore 11/20/2019
Michele Moore
JT320610
Prince Telecom LLC 206-388-4316
Michele Moore 206-388-4316
13701 24th St E Bld G,Sumner WA 98390
michele.moore@princetelecom.com
17803 108th Ave Se Renton WA S of Carr Road/Petrovisk
Between 8 AM -4 PM
TBD
Reset FormPrintForm
MFP19006232
Monday - Friday
Scott Warlick
11/20/2019
9:00am - 3:00pm
SKETCH
I
-- NORTH --
I
NOTES:
• Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by sketch or reference to WSDOT.
• The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three
working days prior to work.
• Approved Temporary Traffic Control Plan must be at the work site during work hours.
• Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected
by a temporary lane or road closure.
• Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded.
• Total road closure lasting more than 24 hours is subject to the approval by the City Council.
• Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
• Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
• Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
72 hours in advance of effective date and time.
• The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
• Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop
(3555 NE 2nd Street).
Se Carr RdDRIVEWAY270' taperPole <18'>NORTHNOT TO SCALEKENNY"S TRAFFIC ZONE PLANS
Kenny Stertz
Longview , Wa
traficplayr@aol.com
TCS # 5663
NOTES:
-Sidewalk shall remain open
-Spotter will be onsite to help any
Pedestrians get pass the work area
108th Ave se
SPOTTER -
TacoBell
DRIVEWAYDRIVEWAYSe 180th StC350'W4-2350'AB350'RIGHT LANECLOSEDAHEADW20-5ROADWORKAHEADW20-1SIGN SPACING = X (FEET) (1)
FREEWAYS & EXPRESSWAYS
RURAL HIGHWAYS
RURAL ROADS
RURAL ROADS and URBAN ARTERIALS
RURAL ROAD, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS
ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED
55/70 mph
60/65 mph
45/55 mph
35/40 mph
25/30 mph
25mph or less
1500ft +/-
800ft +/-
500ft +/-
350ft +/-
200ft +/-(2)
100ft +/-(2)
(1) All spacing may be adjusted to accomodate interchange ramps, at-gradeintersections, and driveways.(2) This spacing may be reduced in urban areas to fit roadway conditions.
CHANNELIZING DEVICE SPACING CHART (FEET)
50/70
35/45
20/30
mph *Half-Spacing*TAPER TANGENT
20
N/A
40
30
20
80
60
40N/A
BUFFER DATALONGITUDINAL BUFFER SPACE = B
SPEED (mph)
LENGTH (ft)25 30 35 40 45 50 55 60 65 70
155 200 250 305 360 425 495 570 645 730
TYPICAL PROTECTIVEVEHICLE TYPEWITH TMA
TYPICAL PROTECTIVE VEHICLE(WITH TMA) LOADED WEIGHT(LBS)
STATIONARYOPERATION(ft)
30 MIN.
100 max.
MINUMIM WEIGHT 16000 LBS(MAXIMUM WEIGHT SHALL BE IN ACCORDANCEWITH MANUFACTURER RECOMMENDATION
4 YARD DUMP TRUCKSERVICE TRUCKFLAT BED, ETC
PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCE
LONGITUDINAL BUFFER SPACE = B
ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT
A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF A TMA IS AVAILABLE IF NO TMA IS USED,THE PROTECTIVE VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO SHIELD WORKERS ANDNO ROLL AHEAD DISTANCE IS SPECIFIED. REFER TO CHAPTER 1.5.5 FOR ADDITIONAL INFORMATION
MERGING, SHIFTING, and SHOULDER TAPER LENGTHSand NUMBER OF CHANNELIZATION DEVICES USED
10ft LANE 11ft LANE 12ft LANE
L L L1/2L 1/2L 1/2L
Lanewidth
MPH Merging Merging MergingDevicesShiftingDevicesDevicesDevicesDevices DevicesShiftingShifting
SHOULDER TAPERS(assume 10ft shoulders)
1/3L Devices(FT)LengthMPH
2025
303540
45505560
6570
70105150205
270450500550600
650700
6
68810161415161719
35
5575105
135225250275300325350
34
55698
899
10
75
115165225
295495550
605660715
770
6799
111815
16181920
4060
85115150250285305330
370385
34556989
91011
80125180245320
540600660
720780840
671091219
1618
192122
406590125160270
300330
360390420
34556
10991011
12
20
25303540
455055
606570
2535507090150170
185200220
235
3334
466
6677
Shoulder tapers equalsshoulder Width x Speed/3
MINIMUM TAPER LENGTH = L (feet)
POSTED SPEED (mph)
25 30 35 40 45 50 55 60 65 70
105
115
125
150
165
180
205
225
245
270
295
320
450
495
540
500
550
600
550
605
660
660
720
-----780 840
LANEWIDTH(feet)
10
11
12
Prince telecom
telecommunications
installation
Michele Moore
425-614-7019
JOB # 320610
ARROWBOARD -
cones -
sidewalk
www.invarion.com
MFP19006232
Spotter may be
needed to help cars
enter traffic on
108th ave SE.
Contractor to bore into Mill Creek ROW starting at existing pedestal E of driveway to 17616 26th Dr SE, boring Southward 46' to South side of street, and Eastward in ROW, 108' to place new flush mount carson box, and turning North exiting ROW to property at 17607 26th DR SE
4
TOTAL FOOTAGE
18.5
18.5
Existing UG =
Riser =
SOW DETAIL VIEW
Bore/Drill New UG =
Trench New UG =
New OH =
Overlash =
COVER SHEET
ENGINEERED FOR:
New Carson Box
New Building Exterior =
New Building Interior =
REVISION DESCRIPTIONS
DATE:BY:REASON:
Scott Barker 509-342-5832
LEGEND
Existing Pole/ Ped
Bore Path
3
ESS COMCAST
0
SECTIONS:SITE CONTACT
0
COVER PAGE 1 0
SOW DETAIL VIEW
Engineering / Design
JT320610 CONTACTS:
SCREEN PRINT PASTE CROP GOOGLE MAP
Area Manager
Comcast SMB Timm Fox (253) 313-6453
17803 108th Avenue SE OPE
Scott Barker 509-342-5832
SOW OVERVIEW DETAIL 2
Renton WA 98055
MFP19006232
DatePrepared By:Scott Barker 509-342-5832 Rev
JB67756 0 12042 SE 42nd CT Bellevue SOW Detail Overview
CONTRACTOR TO BORE 1-2" INTO CITY OF RENTON ROW TO PLACE NEW CONDUIT
FROM EXISTING UTILITY POLE RISER, WESTWARD 18.5" TO PRIVATE PROPERTY. ALL
SUBSTURCTURE TO HAVE 36" COVER.
Date:
ENGINEERED FOR:Plant Extension
0
Comcast ESS
18' ROW BORE FROM
EXISTING UTILITY RISER
WESTWARD TO PRIVATE
PROPERTY
MFP19006232
I
SOW Detail View
Date
CONTRACTOR TO BORE 1-2" INTO CITY OF RENTON ROW TO PLACE NEW CONDUIT FROM EXISTING
UTILITY POLE RISER, WESTWARD 18.5" TO PRIVATE PROPERTY. ALL SUBSTURCTURE TO HAVE 36"
COVER.
Date:
ENGINEERED FOR:Plant Extension
0
Comcast ESS
Prepared By:Scott Barker 509-342-5832 Rev
Place Photo Detail Here
Place Photo Detail HerePlace Photo Detail HerePlace Photo Detail Here
Place Photo Detail Here Place Photo Detail Here
JB67756 0 12042 SE 42nd CT Bellevue
18' ROW BORE FROM
EXISTING UTILITY RISER
WESTWARD TO PRIVATE
PROPERTY
ROW LINE
TIEIN POINT
MFP19006232