Loading...
HomeMy WebLinkAboutR-393018ri coCD M co i 111 SEE SHEET C6.7 D J J �.II -�� �'■ICI ..... ............................................................................... ICI -_ ci=ii■i M .. ...:'.:'....'.... 1 N I u J O O CU Q z LU 73 LU LU rr O I— rr rQ V ) 1 ........ . a — - I I g v g g Al 0. es Iii LJC6.4 II ri Iti ti ri ri ri ri ri ri ri ri ti ti ti ri I� ", I II Lill u J. AS -BUILT y ��A �o� >, — _ 5 RAMP REVISION I CERTIFY THAT THE INFORMATION SHOWN HEREON 4 STORM DRAINAGE REVISIONS WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE NOTICE ■ 3 CITY COMMENTS LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND ALTERAIIONOFTHIS DOCUMENT SHALL NriVALIDATETHE 2 ADDENDUM NO. 3 PROFESSIONAL SEAL AND SIGNATURE PUBLICATION OF AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING THIS DOCUMENT DOES NOT OEROMIEFROM RESERVED °0.P 41803OIINEFSHsv� 41 FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY ONLY �HEEPP�ECTIDa1�TIFIE NTHETINnE� pc �.t�,S'QE01STER�����' TACOMA SEATTLE SPOKANE TRI-CITIES 1 ADDENDUM NO. 1 2 AND IS NOT TO BE USED FOR REPAIR, REMODEL OR S WDIRECT SUPERVISION ON THIS DATE: 08/23/2019. AoolnoNTOTHATPROECTORFORMY07HERPROJECT. IONAL 2215North 30thStreet, Suite 300 Tacoma, WA98403 N0. REVISION Ld �23�201 9253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB CD C I I II II I II I l I II I SEE SHEET C6.7 LEGEND BS BOTTOM OF STEP TS TOP OF STEP TW TOP OF WALL FIG FINISHED GRADE • STORM DRAIN CLEANOUT ■ STORM DRAIN CATCH BASIN, TYPE 1 �■ STORM DRAIN CATCH BASIN, TYPE 2 D STORM DRAIN LINE ROOF DRAIN RD FOOTING DRAIN FD — ----GB — — — —— GRADE BREAK — EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR 355 PROPOSED MAJOR CONTOUR 354 PROPOSED MINOR CONTOUR I LARGE -DIAMETER DETENTION PIPE L- J ILT GENERAL NOTES: 1. ALL OFFSITE TYPE 1 CATCHBASINS SHALL HAVE RECTANGULAR VANED GRATES UNLESS OTHERWISE INDICATED. RECTANGULAR VANED GRATE PER CITY OF RENTON STANDARD PLAN 204.20, SEE DETAIL 4, C7.7. GRAPHIC SCALE 0 20 40 80 1" = 40 FEET CONSTRUCTION RECORD DRAWINGS WJF 2/22/1 8 WJF SURVEYED: D. FOLLANSBEE SCALE: AS SHOWN VERTIHORIZONTAL: HAD D1983/11991 CITY 0F WJF 12/13/17 WJF DESIGNED: G. TAUSCHECK ull*�''Voo;RENTON WJF 4/21/17 WJF DRAwN. WJF 3/17/17 WJF F. KATONA ONE INCH AT FULL SCALE IF NOT ONE INCH DATUM Planning/Building/Public Works Dept. p WJF 3/1/17 1 WJF CHECKED: W. FIERST BY DATE APPR SCALE ACCORDINGLY APPROVED: S. COMFORT APPROVED FOR CONSTRUCTION SUBJECT TO ERRORS AND OMISSIONS BY: DATE: BY: DATE: BY: DATE: BY: DATE: SARTORI ELEMENTARY SCHOOL RENTON SCHOOL DISTRICT OVERALL FRONTAGE IMPROVEMENT PLAN 05/04/2017 FIELDBOOK: PAGE: DRAWING NO: C6.0 SHEET: OF: OF:43 w H H NJ CO T J R-393018