HomeMy WebLinkAboutR-39303002" IRRIGATION PORT,
TYP. 2 PLACES
A
J
Z Q
I
1
I
I
VAULT LENGTH
(MEDIA BAY
UNDERDRAIN
L r L�
FLOW FLOW
4' CURB
INLET
F -TF - OPENING
qr
-- - ---�� PLAN VIEW
PLANT
- - ---- - - J
w
ALTERNATE ORIENTATION PROVIDED BY
CONTECH
CLEAN OUT FRAME AND
COVER CAST INTO TOP SLAB
TOP SLAB BYPASS
PIPE
2'-0"
JUNCTION
CHAMBER
A
a0ll
24" ACCESS
1-1—-1
CURB
NOT BY CONTECH
OUTLET PIPE
BY NOT BY CONTECH
(LOCATION VARIES)
TREE FRAME AND GRATE
CAST INTO TOP SLAB
TERRAFLUME TRAY
WITH BYPASS STUB
24" ACCESS COVER AND FRAME
CAST INTO TOP SLAB
II =_
�at.n MuP n: •
i
•-• a a
.
LU
Q a-
c) Lu O
Q i O
00 Z
CO
JUNCTION
CHAMBER
3" MULCH LAYER
PROVIDED BY CONTECH
F1111 �011i.
/MITI 1011110
%/,������ i %%i�7
��/i1700/1"
��� i%/�i� ��//.
��� MIM/����/0�
,,,l
� o?,/ IZIW I��r(//�
/��/V�z�%1.0X�1
����
z1z/1 � ���WC
�/��10
��i=������/.11=�
� ���%
���i% J/�F7=00
11•
1 •
1
• 1
1 �-
• �-
��!%//ice
NTERNAL PIPE CONFIGURATION MAY VARY DEPENDING ON VAULT SIZE
A
J
D p
I
I
I
I
VAULT LENGTH CURB
(MEDIA BAY 2'_0" > NOT BY CONTECH
JUNCTION CHAMBER O
J 11 LL
�I-------- - A
TERRAFLUME TRAY
WITH BYPASS STUB
LU
z
I, , I :;t
�a-
24" ACCESS Ull O
L _7I--------LJ--� 1
O
UNDERDRAIN � —�F --— ------
02" IRRIGATION PORT, OUTLET
OTHERS
TYP. 3 PLACES
TREE FRAME AND GRATE _
CAST INTO TOP SLAB
CLEAN OUT FRAME
AND COVER CAST INTO
TOP SLAB
TOP SLAB
z
N<I—a-
Q 0� Q
rf
6 UNDERDRAIN
STONE LAYER
21" FILTERRA MEDIA
(LOCATION VARIES) UD
PLAN VIEW __-
L BP�L----
PLANT
PROVIDED BY ALTERNATE ORIENTATION
CONTECH
24" ACCESS COVER
AND FRAME CAST
INTO TOP SLAB
JAI
3" MULCH LAYER
UNDERDRAIN FLOWKIT
SECTION A -A
INTERNAL PIPE CONFIGURATION MAY VARY DEPENDING ON VAULT SIZE
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered 5owtlons LLG or one of Its attulated companies (Uontecrt"). Nertner tnls drawing, nor any part trtereot, may be used, reproduced or modmed in any manner
without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use. If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site
work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
DIMENSIONS MAY VARY ±
%2" DEPENDING ON
PRECASTER BUILD
CONFIGURATION.
LONG SIDE CURB INLET
NOT TO SCALE
AS -BUILT
I CERTIFY THAT THE INFORMATION SHOWN HEREON
WHICH WAS AS -BUILT BY AHBL ,AND MAY INCLUDE NOTICE
LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND ALTERATION aFTHIS DOOIYENrSHALLNVMIDAIETIE
PROFESSIONAL SEAL AND SIGNATURE PUBLICATION OF
CI11E11
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING THIS DOTDOES NOT DEROGATEFROM RESERVED
OINER9IP
DDCUIENT IS FOR USE
FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY araYFOR THE PROJECT IDENTI�1EDNTHE nTLEBLoac
AND IS NOT TO BE USED FOR REPAIR, REMODEL OR
DIRECT SUPERVISION ON THIS DATE: 08/23/2019. ADonIDNTOTNArPRaECTaRFaRANroTNERPRo�Ecr.
a
Ld
CDS®
THIS PRODUCT MAYBE PROTECTED BY ONE OR MORE OF THE
FOLLOWING U.S. PATENTS: 5,788,848; 6,641,720; 6, 511,595; 6,581,783:
RELATED FOREIGN PATENTS, OR OTHER PATENTS PENDING.
C;V4 N T E C H
ENGINEERED SOLUTIONS LLC
9025 CentlL, , Ln., oufte 4uu, VVUbL unester, OH 45069
800-526-3999 513-645-7000 513-645-7993 FAX
SHORT SIDE CURB INLET
NOT TO SCALE
J.
y Cl:)) �o� �, 5 RAMP REVISION
4 STORM DRAINAGE REVISIONS
W = 3 CITY COMMENTS
,ter 2 ADDENDUM NO. 3
���EGI,$�EF� �yTACOMA SEATTLE SPOKANE TRI-CITIES 1 ADDENDUM NO. 1
��
�SSIONAL 2215 North 30th Street, Suite 300 Tacoma, WA98403 N0. REVISION
/23/201 9253.383.2422 TEL 253.383.2572 FAX wm ahbl.com NEB
TERRAFLUME TRAY
WITH BYPASS STUB
CURB AND GUTTER, TYP.
_ (NOT BY CONTECH)
SEE FILTERRA w/ TERRAFLUME
CURB INLET DETAIL SHEET
:.:. lcl I
STREET
O (� LU H
M � � z 0
I c0
JUNCTION
CHAMBER
WJF
2/22/1 8
WJF
SURVEYED:
SCALE:
D. FOLLANSBEE
AS SHOWN
WJF
12/13/17
WJF
DESIGNED:
G. TAUSCHECK
WJF
4/21/17
WJF
WJF
3/17/17
WJF
DROWN:
F. KATONA
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
WJF
3/1/1 7
WJF
CHECKED:
W. FIERST
BY
DATE
APPR
SCALE ACCORDINGLY
APPROVED:
S. COMFORT
NOTES:
1. PROVIDE LOCAL DEPRESSION AT POINT A
2. MATCH NORMAL PAVEMENT GRADE AT POINT B
3. VARY TRANSITION SECTION SLOPES TO MATCH ABOVE POINTS
NORMAL
GUTTER
FLOWLINE
DEPRESSED NOSING A
GUTTER
FLOW LINE
L ——
FILTERRA
THROAT
OPENING
-- + -------J
GUTTER FLOW
DEPRESSION PER
LOCAL REGULATIONS
ELEVATION VIEW
STANDARD 90' NOSING
(OTHER NOSING AVAILABLE PRECAST
UPON REQUEST) TOP SLAB
1 4" MIN.CLEAR
9" THROAT
OPENING
v
a�
CAST -IN -PLACE GUTTER
AND THROAT OPENING
(BY CONTRACTOR PER
LOCAL STANDARDS)
#4 DOWEL BARS @ 12" O.C. BY CONTECH
TO BE BENT AS NECESSARY BY
CONTRACTOR PRIOR TO INSTALLATION
OF CAST -IN -PLACE GUTTER
INSIDE CEILING
OF TOP SLAB
TOP OF CURB
CURB
> FACE'
CIP
GUTTER'
VARIES, SEE
PROJECT SPECIFIC
SITE PLANS
a iG d d
a d 8„
TYPICAL
NNa Q
d d d
77
II I I
a 6" MAX. CLEAR
a THROAT OPENING
TERRAFLUME OUTLET
PROTECTION DEVICE
° DO NOT REMOVE - LEAVE IN
PLACE UNTIL SITE IS STABILIZED
AND FILTERRA IS ACTIVATED
PRECAST VAULT WALL
SECTION A -A VIEW
STANDARD CURB INLET WITH TERRAFLUME �filrerra
N.T.S. es,azs.e,,a a, nEa.EaFnaennPA.e.e
�1
The des a d' f t how n th s draw tl d ce to the ect owner a and contractor b CONTECH En -n red Solt LLC f 1 ffli t tl CONTECH N �h th' d art thereof m be u d r rod—d or motl'f'ed m gn n o g p a sery prod ng neer y g ee ne p ( ) g r any p ay ep any
wtho th p - n con ent of CONTECH. F to comply s done at the users own "s, and CONTECH expressly tl scla ms any ati l ry p -I, lily f h If d p betty h ppl d f t pon wli ch the draw ng -s based and actual f eld cond tons are
ounrte,ed as ste work progressessth—dsc pances must be rep—d to CONTECH -m lately for re-evaluation of-d gn. CONTECH accepts not ably br desgns based on mssng,-n o Ibb, urate'nfo,maton suppled by others.
C '. NTECH• FILTERRA WITH TERRAFLUME
ENGINEERED SOLUTIONS LLC CURB URB INLET DETAIL
9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069
800-338-1122 513-645-7000 513-645-7993 FAX I DATE:7/6/16 1 FILENAME: FILTERRA W TERRAFLUME CURB INLET DETAIL.DWG DRAWN: DWB CHECKED:
FILTERRA WITH TERRAFLUME CURB INLET
NOT TO SCALE
CONSTRUCTION RECORD DRAWINGS
NOR ZONTAL: NAD Di 983/11991 1,1 J
+�; CITY OF
R E N TO N
DATUM
Plonning/Building/Public Works Dept.
APPROVED FOR CONSTRUCTION
SUBJECT TO ERRORS AND OMISSIONS
BY:
DATE:
BY:
DATE:
BY:
DATE:
BY:
DATE:
SARTORI ELEMENTARY SCHOOL
RENTON SCHOOL DISTRICT
FILTERRA DETAILS
05/04/2017
FIELDBOOK:
PAGE:
DRAWING NO:
C7.4
SHEET: OF:
34 43
�•
•
•
N®RN
O
O
O
I
C9
R-393030