Loading...
HomeMy WebLinkAboutR-39303002" IRRIGATION PORT, TYP. 2 PLACES A J Z Q I 1 I I VAULT LENGTH (MEDIA BAY UNDERDRAIN L r L� FLOW FLOW 4' CURB INLET F -TF - OPENING qr -- - ---�� PLAN VIEW PLANT - - ---- - - J w ALTERNATE ORIENTATION PROVIDED BY CONTECH CLEAN OUT FRAME AND COVER CAST INTO TOP SLAB TOP SLAB BYPASS PIPE 2'-0" JUNCTION CHAMBER A a0ll 24" ACCESS 1-1—-1 CURB NOT BY CONTECH OUTLET PIPE BY NOT BY CONTECH (LOCATION VARIES) TREE FRAME AND GRATE CAST INTO TOP SLAB TERRAFLUME TRAY WITH BYPASS STUB 24" ACCESS COVER AND FRAME CAST INTO TOP SLAB II =_ �at.n MuP n: • i •-• a a . LU Q a- c) Lu O Q i O 00 Z CO JUNCTION CHAMBER 3" MULCH LAYER PROVIDED BY CONTECH F1111 �011i. /MITI 1011110 %/,������ i %%i�7 ��/i1700/1" ��� i%/�i� ��//. ��� MIM/����/0� ,,,l � o?,/ IZIW I��r(//� /��/V�z�%1.0X�1 ���� z1z/1 � ���WC �/��10 ��i=������/.11=� � ���% ���i% J/�F7=00 11• 1 • 1 • 1 1 �- • �- ��!%//ice NTERNAL PIPE CONFIGURATION MAY VARY DEPENDING ON VAULT SIZE A J D p I I I I VAULT LENGTH CURB (MEDIA BAY 2'_0" > NOT BY CONTECH JUNCTION CHAMBER O J 11 LL �I-------- - A TERRAFLUME TRAY WITH BYPASS STUB LU z I, , I :;t �a- 24" ACCESS Ull O L _7I--------LJ--� 1 O UNDERDRAIN � —�F --— ------ 02" IRRIGATION PORT, OUTLET OTHERS TYP. 3 PLACES TREE FRAME AND GRATE _ CAST INTO TOP SLAB CLEAN OUT FRAME AND COVER CAST INTO TOP SLAB TOP SLAB z N<I—a- Q 0� Q rf 6 UNDERDRAIN STONE LAYER 21" FILTERRA MEDIA (LOCATION VARIES) UD PLAN VIEW __- L BP�L---- PLANT PROVIDED BY ALTERNATE ORIENTATION CONTECH 24" ACCESS COVER AND FRAME CAST INTO TOP SLAB JAI 3" MULCH LAYER UNDERDRAIN FLOWKIT SECTION A -A INTERNAL PIPE CONFIGURATION MAY VARY DEPENDING ON VAULT SIZE The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered 5owtlons LLG or one of Its attulated companies (Uontecrt"). Nertner tnls drawing, nor any part trtereot, may be used, reproduced or modmed in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use. If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others. DIMENSIONS MAY VARY ± %2" DEPENDING ON PRECASTER BUILD CONFIGURATION. LONG SIDE CURB INLET NOT TO SCALE AS -BUILT I CERTIFY THAT THE INFORMATION SHOWN HEREON WHICH WAS AS -BUILT BY AHBL ,AND MAY INCLUDE NOTICE LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND ALTERATION aFTHIS DOOIYENrSHALLNVMIDAIETIE PROFESSIONAL SEAL AND SIGNATURE PUBLICATION OF CI11E11 AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING THIS DOTDOES NOT DEROGATEFROM RESERVED OINER9IP DDCUIENT IS FOR USE FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY araYFOR THE PROJECT IDENTI�1EDNTHE nTLEBLoac AND IS NOT TO BE USED FOR REPAIR, REMODEL OR DIRECT SUPERVISION ON THIS DATE: 08/23/2019. ADonIDNTOTNArPRaECTaRFaRANroTNERPRo�Ecr. a Ld CDS® THIS PRODUCT MAYBE PROTECTED BY ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,788,848; 6,641,720; 6, 511,595; 6,581,783: RELATED FOREIGN PATENTS, OR OTHER PATENTS PENDING. C;V4 N T E C H ENGINEERED SOLUTIONS LLC 9025 CentlL, , Ln., oufte 4uu, VVUbL unester, OH 45069 800-526-3999 513-645-7000 513-645-7993 FAX SHORT SIDE CURB INLET NOT TO SCALE J. y Cl:)) �o� �, 5 RAMP REVISION 4 STORM DRAINAGE REVISIONS W = 3 CITY COMMENTS ,ter 2 ADDENDUM NO. 3 ���EGI,$�EF� �yTACOMA SEATTLE SPOKANE TRI-CITIES 1 ADDENDUM NO. 1 �� �SSIONAL 2215 North 30th Street, Suite 300 Tacoma, WA98403 N0. REVISION /23/201 9253.383.2422 TEL 253.383.2572 FAX wm ahbl.com NEB TERRAFLUME TRAY WITH BYPASS STUB CURB AND GUTTER, TYP. _ (NOT BY CONTECH) SEE FILTERRA w/ TERRAFLUME CURB INLET DETAIL SHEET :.:. lcl I STREET O (� LU H M � � z 0 I c0 JUNCTION CHAMBER WJF 2/22/1 8 WJF SURVEYED: SCALE: D. FOLLANSBEE AS SHOWN WJF 12/13/17 WJF DESIGNED: G. TAUSCHECK WJF 4/21/17 WJF WJF 3/17/17 WJF DROWN: F. KATONA ONE INCH AT FULL SCALE IF NOT ONE INCH WJF 3/1/1 7 WJF CHECKED: W. FIERST BY DATE APPR SCALE ACCORDINGLY APPROVED: S. COMFORT NOTES: 1. PROVIDE LOCAL DEPRESSION AT POINT A 2. MATCH NORMAL PAVEMENT GRADE AT POINT B 3. VARY TRANSITION SECTION SLOPES TO MATCH ABOVE POINTS NORMAL GUTTER FLOWLINE DEPRESSED NOSING A GUTTER FLOW LINE L —— FILTERRA THROAT OPENING -- + -------J GUTTER FLOW DEPRESSION PER LOCAL REGULATIONS ELEVATION VIEW STANDARD 90' NOSING (OTHER NOSING AVAILABLE PRECAST UPON REQUEST) TOP SLAB 1 4" MIN.CLEAR 9" THROAT OPENING v a� CAST -IN -PLACE GUTTER AND THROAT OPENING (BY CONTRACTOR PER LOCAL STANDARDS) #4 DOWEL BARS @ 12" O.C. BY CONTECH TO BE BENT AS NECESSARY BY CONTRACTOR PRIOR TO INSTALLATION OF CAST -IN -PLACE GUTTER INSIDE CEILING OF TOP SLAB TOP OF CURB CURB > FACE' CIP GUTTER' VARIES, SEE PROJECT SPECIFIC SITE PLANS a iG d d a d 8„ TYPICAL NNa Q d d d 77 II I I a 6" MAX. CLEAR a THROAT OPENING TERRAFLUME OUTLET PROTECTION DEVICE ° DO NOT REMOVE - LEAVE IN PLACE UNTIL SITE IS STABILIZED AND FILTERRA IS ACTIVATED PRECAST VAULT WALL SECTION A -A VIEW STANDARD CURB INLET WITH TERRAFLUME �filrerra N.T.S. es,azs.e,,a a, nEa.EaFnaennPA.e.e �1 The des a d' f t how n th s draw tl d ce to the ect owner a and contractor b CONTECH En -n red Solt LLC f 1 ffli t tl CONTECH N �h th' d art thereof m be u d r rod—d or motl'f'ed m gn n o g p a sery prod ng neer y g ee ne p ( ) g r any p ay ep any wtho th p - n con ent of CONTECH. F to comply s done at the users own "s, and CONTECH expressly tl scla ms any ati l ry p -I, lily f h If d p betty h ppl d f t pon wli ch the draw ng -s based and actual f eld cond tons are ounrte,ed as ste work progressessth—dsc pances must be rep—d to CONTECH -m lately for re-evaluation of-d gn. CONTECH accepts not ably br desgns based on mssng,-n o Ibb, urate'nfo,maton suppled by others. C '. NTECH• FILTERRA WITH TERRAFLUME ENGINEERED SOLUTIONS LLC CURB URB INLET DETAIL 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 800-338-1122 513-645-7000 513-645-7993 FAX I DATE:7/6/16 1 FILENAME: FILTERRA W TERRAFLUME CURB INLET DETAIL.DWG DRAWN: DWB CHECKED: FILTERRA WITH TERRAFLUME CURB INLET NOT TO SCALE CONSTRUCTION RECORD DRAWINGS NOR ZONTAL: NAD Di 983/11991 1,1 J +�; CITY OF R E N TO N DATUM Plonning/Building/Public Works Dept. APPROVED FOR CONSTRUCTION SUBJECT TO ERRORS AND OMISSIONS BY: DATE: BY: DATE: BY: DATE: BY: DATE: SARTORI ELEMENTARY SCHOOL RENTON SCHOOL DISTRICT FILTERRA DETAILS 05/04/2017 FIELDBOOK: PAGE: DRAWING NO: C7.4 SHEET: OF: 34 43 �• • • N®RN O O O I C9 R-393030