Loading...
HomeMy WebLinkAboutR-3930340 rn M I I W ASPHALT CONCRETE OVERLAY 2" MIN. CEMENT REMOVE LOOSENED TRIM CONCRETE ASPHALT VERTICALLY 3/4' DIA. X 12" LONG DOWEL `- BAR 0 18" ON CENTER 6" EXISTING RIGID BASE* MIN. 12" MIN. COMPACTED TRENCH BACKFILL AS DIRECTED BY THE ENGINEER SAW CUT SHALL BE VERTICAL AND IN STRAIGHT LINES AS DIRECTED BY THE ENGINEER /EXISTING CONCRETE / PAVEMENT EPDXY COATED DOWEL BARS 6" MIN. ON ALL FOUR SIDES 12" I COMPACTED CRUSHED SURFACING TOP COURSE. CUT AND PANEL REPLACEMENT DETERMINATION: FULL CEMENT CONCRETE PANEL REPLACEMENT: FOR CEMENT CONCRETE SURFACE STREETS, THE MINIMUM RESTORATION SHALL BE FULL PANEL REPLACEMENT, IF ONE OR MORE OF THE FOLLOWING CONDITIONS EXIST - Less than ten (10) yrs old Ten (10) yrs or older Additional Requirements Local Access without Bus Route No No Local Access with Bus Yes Yes Route Intersection (All Yes Yes Plus one panel beyond Streets) the curb return 40% Removal Yes Yes Excellent Condition (based on visual and/or Yes Yes non—destructive testing) Principal, Minor, Yes, If twenty—four (24) Yes, If twenty—four (24) Collector Arterial and square feet or more of square feet or more of all streets in CBD any panel needs to be any panel needs to be and all bus route patched patched *CDF BACKFILL MAY BE USED IN LIEU OF RESTORING EXISTING RIGID BASE AT THE DISCRETION OF THE ENGINEER. TYPICAL PATCH FOR RIGID PAVEMENT PAVEMENT PATCHING AND RESTORATION DETAIL 1sY p ADOPTED G CTTY OF RENTON ♦ � a STANDARD PLANS IS'T DATE: 04/04 DWG. NAME: H033 SP PAGE: HO33 TYPICAL PATCH FOR RIGID PAVEMENT PATCHING AND RESTORATION DETAIL (H033) NOT TO SCALE AS -BUILT I CERTIFY THAT THE INFORMATION SHOWN HEREON WHICH WAS AS -BUILT BY AHBL ,AND MAY INCLUDE NOTICEISD LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND ALTERATION aFTHOCI1YENrSHALL NVMIDAIETIE PROFES90NAL SEAL AND SNNATUREUBL PUBLICATION OF AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING THIS DOCI11E11TDOES NOT DEROGATEFROM RESERVED OIMER9IP RN1113 N ff.-`HIS DOCUIENT IS FOR USE FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY �PIsa rFaNTHEEcrIBENTIREBNeloac THEnTLE AND IS NOT TO BE USED FOR REPAIR, REMODEL OR DIRECT SUPERVISION ON THIS DATE: 08/23/2019. ADDI110NTOTHArPRO,ECTaRFORANTOTHERPRo�icT. a BAND - OR NOTES 1 G1111 61MENSIONSI FOIR ITHE104RTS USED TO ASSEMBLE THE BASE ONNECTIONS INTENTIONALLY (ARE NOT SHOWN. BASE ONNEC TIO14S (IARE PATENTED, MANUFACTURED PRODUCTS IAREIINI (COMPLIANCE WITH NCHRP 350 CRASH TEST ��THATi RITERIA ,(THE',IBASE(CONNECTION DETAILS ARE SHOWN ON kl'§IlbEAN!�IQNLYIIT0, ILLUSTRATE HOW THE PARTS ARE ASSEMBLED:`-; 12l i A ;2 I ((IN)IOOSTI �M1I,TIi A 2 1 /4" (IN) PSST ANCHOR OR A 2 il' )4`�II(IN}{�,PQSTi;W�TH�,A 2 1/2" (IN) PSST ANCHOR MAY BE UBSTFTUTED�,ISEE ICONTRACT PLANS. 13 ERFORATEDIIdSQUARE (STEEL POST SHALL MEET THE REQUIREMENTS, OFII;WSDOTIiSTANDARD SPECIFICATION 9-06. • 'SE 11QNLY"IbAISE{�CQ'NNECTION MANUFACTURER SUPPLIED HAkbWARE:1'T'HAT ;MEETS THE REQUIREMENTS OF WSDOT ISTANDAR•pSPECIFICATIONS 9-06 AND 9-28. MOUNTING ON EXISTING METAL POLE OR LUMINAIRE EDGE OF TRAVELED ROADWAY 90' 30' —1 l t3*— L. DGE' 10F' i f j jREFL MOUNT FACING�(3f � 9Fe'°1�fO0INS: SWARD IF SIGN _ IS IWITHIN1,301'iPEET OF'ROADWAY GALVANIZED( BOLT WITH GALVANIZED WASHERS,, it it1GNi*ACE ORIENTATION I METAL POST' ° o TOP OF ANCHOR z Q 1 SIGN 00SF' J a� W (LOWER SQUAR-': Ti CJ �r0) I' r of FINISHED CD a GROUN I, ° ° LINE d� L y4ER SiG 4 (� 5/16" (IN) CORNER BOLT O I. IPPST P. OiJ -" OR 3/8 (IN) FLANGED SHOULDER BOLT WITH NUT AND WASHERS — L 2 REQUIRED (TYP.) r� - r z BOLT STOP IGN POST > III (TYPE ST-4 SIGN SUPPORT t 'I LOWER SIGN � 2;251�"' POSTIISUPPORT;� (IN) GAG � HOT 1 l ..GALV,I NM. .9 HEAVY—DUTiY',ANCHQRi IA GbMMERCIAIL boONicRETEI MOUNTING ON METAL POST'' 7 II 1 o� I SIGN MOIJNTLNG 10N SINGLE STD. PLAN— 129 Gti�Y ®� PUBLIC WORKS DEPARTMENT ME•TA'I! PST' APPROVED: FNTo ADO$ )" I( TEB (r� SIGN MOUNTING ON SINGLE METAL POST (COR STD. PLAN 129) CENTER CENTER IN IN LANE LANE 10 6"MIN.(TYP.) LANE GUTTER[,, —CONCRETE LINE 24" SNP') LE AN LINE I I 8"(TYP.)—STRIF 8"(TYP.)—OPEN 8"(TYP.)—STRIPE —1IKt. -"--IIKIL / "—IIKr_ / —11 / TRACKS —)TRACKS—/ TRACKS—` TRACKS—) * TYPICAL 4-LANE ROADWAY CONFIGURATION * NOTE: FOR ROADWAYS WITH MORE OR LESS LANES, THE SAME CONFIGURATION APPLIES. KEEPING THE THERMOPLASTIC/PAINTED BARS CENTERED ON THE LANE LINES AND IN THE CENTER OF TRAVELLED PORTION OF THE LANE TO MINIMIZE THE WEAR ON THE THERMOPLASTIC/PAINT. ti`�Y o +'+ PUBLIC WORKS THERMOPLASTIC/PAINTED RDA STD. PLAN — 127 . DEPARTMENT CROSSWALK 4TE D THERMOPLASTIC/PAINTED CROSSWALK (COR STD. PLAN 127) NOT TO SCALE 1 v J NOT TO SCALE 1 r-o • 024" x 4" 6„ 2'-0" SOLID COVER 4'-3" FLUSH MOUNT (CAST -IN) I I I I I I I I co N A I I I I T/I } A pD IRRIGATION ! _ I I1 _ a.Jr_„I IIT— N SYSTEM CONDUIT 02" PVC (CAST -IN) TREE GRATE 3 PLACES 24" X 24" X 4" SQ 07" X 8" CLEANOUT (CAST INTO INLET GRATE SEPARATE COLLAR) L FLUSH MOUNT ,.,, . (CAST -IN) n CURB BY OTHERS WEIR z—� FLOWKIT SECTION A -A RIM ELEV. = 35.89't FL ELEV. = 35.39't WEIR ELEV. = 34.56'3 N INLET PIPE INV. ELEV. = 33.06' ° OUTLET PIPE =�=4 INV. ELEV. = 32.47' 0 B OUTSIDE BOTTOM ELEV. = 31.89' eW=E-o> OCR INLET PIPE (O,V G) INLUPPWNIX PRECAST FILTERRA UNIT INTERNAL BYPASS - GRATE INLET T J NOT TO SCALE vtiloy lrasg c�o��� 5 RAMP REVISION WJF 2/22/18 WJF SURVEYED: SCALE: � D. FOLLANSBEE 4 STORM DRAINAGE REVISIONS WJF 12/13/17 WJF DESIGNED: AS SHOWN 3 CITY COMMENTS WJF 4/21/17 WJF G. TAUSCHECK „ter 2 ADDENDUM NO. 3 WJF 3/17/17 WJF DRAWN. F. KATONA ONE INCH ��0' 7EGI,$�EF� �ww TACOMA•SEATTLE•SPOKANE•TRI-CITIES 1 ADDENDUM NO. 1 WJF 3/1/17 WJF CHECKED: AT FULL SCALE �SSIONAL E��l W. FIERST SIF CALE T ONE INCH 2215 North 30th Street, Suite 300 Tacoma, WA98403 NO. REVISION BY DATE APPR APPROVED: /23/201 9253.383.2422 TEL 253.383.2572 FAX www.ahbl.com NEB S. COMFORT ii � 04" SDR 35 OVC OUTLET COULING �I CAST INTO WALL 24" X 4" OPENING 1-nSECTION B-B IRRIGATION SYSTEM CONDUIT 02" PVC (CAST -IN) 3 PLACES V-3" FILTERRA MEDIA OUTLET PIPE — CONSTRUCTION RECORD DRAWINGS VERTIAL:HORIZONTAL: HADDi983/11991 1 Ua CITY OF +eta RENTON DATUM Planning/Building/Public Works Dept. BY: BY: BY: BY: APPROVED FOR CONSTRUCTION SUBJECT TO ERRORS AND OMISSIONS DATE: DATE: DATE: DATE: SARTORI ELEMENTARY SCHOOL RENTON SCHOOL DISTRICT SURFACING NOTES AND DETAILS IV 05/04/2017 FIELDBOOK: PAGE: DRAWING NO: C7.11 SHEET:OF: 41 43 i 0 CD CD Q0 R-393034