HomeMy WebLinkAboutR-393049-__mS W Ime"k lK01=061►1 k 1111690111 APPROXIMATE LOCATION OF P.O.C. TO 2" STUB -OUT FROM IRRIGATION SERVICE LINE AS SHOWN ON CIVIL DRAWINGS. STATIC PRESSURE PER CITY OF RENTON IS 68 PSI. NOTIFY OWNER OF ANY DISCREPANCIES BEFORE COMMENCING WORK. LOCATE CONTROLLER INSIDE BUILDING WHERE INDICATED ON ELECTRICAL PLANS. PROVIDE SEPARATE 15 AMP CIRCUIT AND 120 VAC POWER TO CONTROLLER. PROVIDE 2" CONDUIT FROM CONTROLLER, UNDER SIDEWALK, AND INTO THE NEAREST PLANTING AREA AS SHOWN. EXTEND 24" INTO PLANTING BED, 18" BELOW GRADE. CAP AND FLAG. r e_ i t-J, SCALE: 1 "=40'-0" 0' 20' 40' 80' 160' IRRIGATION NOTES: 1. ADJUST ALL IRRIGATION HEADS TO PROVIDE MAXIMUM COVERAGE, MINIMUM OVERSPRAY, AND NO FOGGING. SET ALL HEADS BACK FROM CURBS, PAVING, AND WALLS. 2. LOCATION OF IRRIGATION MAINLINE, LATERALS, AND SLEEVING ARE SCHEMATIC ONLY, AND SHALL OCCUR IN PLANTING AREAS UNLESS SLEEVING IS SHOWN. IF SLEEVES ARE SHOWN THEY ARE TO BE STRAIGHT RUNS, TYP. MAKE MINOR CHANGES TO COORDINATE WITH ACTUAL AS -BUILT DIMENSIONS AND CONDITIONS. 3. VALVE BOXES SHALL BE LOCATED IN SHRUB PLANTING AREAS ONLY. LOCATE IN APPROXIMATE LOCATIONS AS SHOWN ON PLAN. 4. SEE CIVIL PLANS FOR LOCATION OF IRRIGATION STUB -OUT FROM 2" METER. 5. ANTICIPATED AVAILABLE STATIC WATER PRESSURE IS 68 PSI, AS PROVIDED BY CITY OF RENTON. VERIFY EXACT PRESSURE AT POINT OF CONNECTION PRIOR TO START OF WORK. 6. THE IRRIGATION SYSTEM HAS BEEN DESIGNED WITH SEPARATE HYDROZONES ACCORDING TO THE NEEDS OF THE PLANT MATERIAL. THE IRRIGATION SYSTEM HAS BEEN DESIGNED TO PROVIDE A MINIMUM AVERAGE DISTRIBUTION UNIFORMITY OF 0.625. THE IRRIGATION SYSTEM HAS BEEN DESIGNED TO AVOID RUNOFF, LOW HEAD DRAINAGE, AND OVERSPRAY. AVOID IRRIGATION DURING TIMES OF HIGH WINDS, WHEN RAINING, OR DURING THE MIDDLE OF THE DAY. 7. WHERE IRRIGATION PIPING IS SHOWN ADJACENT OR UNDER EXISTING TREES, MAKE MINOR ROUTE ADJUSTMENTS TO AVOID TRENCHING THROUGH LARGE TREE ROOTS. REFER TO SPECIFICATION SECTION 02810 FOR FURTHER INSTRUCTIONS. 8. REFER TO IRRIGATION SPECIFICATION FOR ADDITIONAL REQUIREMENTS. ZONE SUMMARY ZONE GPM SI PLANT TYPE 1 12.0 1.5" SHRUB DRIP 2 43.7 1.5" SHRUB SPRAY 3 18.2 1" SHRUB SPRAY 4 49.8 1.5" SHRUB SPRAY 5 33.5 1.5" LAWN ROTOR 6 27.4 1.5" LAWN ROTOR 7 37.4 1.5" LAWN ROTOR 8 29.9 15' LAWN ROTOR 9 39.8 1.5" LAWN ROTOR 10 37.4 1.5" LAWN ROTOR 11 43.5 1.5" LAWN ROTOR 12 6.0 1 " TREE BUBBLER 13 40.0 1.5" SHRUB SPRAY 14 32.2 1.5" SHRUB SPRAY 15 11.2 15' SHRUB SPRAY 16 48.9 1.5" SHRUB SPRAY 17 32.3 1.5" SHRUB SPRAY 18 37.0 15' LAWN ROTOR 19 36.6 1.5" SHRUB SPRAY 20 16.0 1" L TREE BUBBLER 21 SPARE WIRE 21 SPARE WIRE R-393049 RECORD DRAWING THE INFORMATION ON THIS DRAWING INDICATES CHANGES MADE TO THE CONSTRUCTION DOCUMENTS AS RECORDED BY THE CONTRACTOR AND TRANSFERRED TO THE REPRODUCIBLE DRAWINGS BY THE ARCHITECT. THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR THE ACCURACY OR RELIABILITY OF THE INFORMATION PROVIDED. O O Ja In1 L O L Date: Job No.: Drawn By: 10/16/19 21607.00 NL Checked by: NH Revisions # Date Description OVERALL IRRIGATION PLAN L300 RECORD DRAWING