HomeMy WebLinkAboutR-393052IRRIGATIONLEGEND (SYMBOLS SHOWN AT 1"=20'-0")
SYMBOL ITEM MANUFACTURER / CAT NO. DESCRIPTION -REMARKS
FC-1 CONTROLLER
FR_1 AUTOMATIC RAIN SHUTOFF
NO SYMBOL CONTROL WIRES
0
SPRAY 4
TYPE 1.5"
50.6
RAINBIRD ESP-LX BASIC (24 STATIONS)
RAINBIRD WR2-RFC
#14 CONTROL AND SPARE WIRES, NO MULTI -STRAND.
DEDUCT METER
POINT OF CONNECTION
BACKFLOW PREVENTER FEBCO 850U (2")
GATE / SHUTOFF VALVE HAMMOND, NIBCO, WILKINS GATE VALVE (2"),
OR APPROVED EQUAL.
STRAINER WILKINS SXL CAST BRONZE 'Y' STRAINER (2")
MANUAL DRAIN CHAMPION 30ORS-200 ANGLE VALVE (2")
QUICK COUPLER
MASTER VALVE
DRIP REMOTE
CONTROL VALVE
K�7►�I:Z�7�9_\\�h
VALVE NUMBER
VALVE SIZE
GALLONS PER MINUTE
ISOLATION VALVE
NO SYMBOL VALVE BOXES
MAINLINE
LATERALS
SLEEVES
---------------
DRIP TUBING
EH EXHAUST HEADER PIPE
SH SUPPLY HEADER PIPE
NO SYMBOL LINE FLUSHING VALVE
NO
SYMBOL
STEEL
SOIL STAPLE
NO
SYMBOL
ZONE
INDICATOR HEAD
RAINBIRD #5RC
55K-1 KEY
SH-2 SWIVEL HOSE ELL
RAINBIRD EFB-CP SERIES VALVE (2")
RAINBIRD DRIP CONTROL ZONES KITS (MEDIUM FLOW)
XCZ-100-COM (1"), FOR FLOWS 3.0-14.99 GPM
RAINBIRD XXX-PEB-PRS-D
SIZE AS SHOWN ON PLAN.
HAMMOND, NIBCO, WILKINS BALL VALVE (2"),
OR APPROVED EQUAL.
SPECIFICATION GRADE (COMMERCIAL GRADE)
VALVE BOXES AND EXTENSIONS.
PVC -SCHEDULE 40
PVC -CLASS 200
PVC -SCHEDULE 40
NETAFIM TECHLINE-CV
TLCV-06-12-10
RAINBIRD XQF (75 or 10) 18100
RAINBIRD XQF (75 or 10) 18100
NETAFIM TLSOV
MANUAL DRIP SHUT-OFF / FLUSH VALVE
RAINBIRD TDS-050 (6" LENGTH)
TORO SPRAY HEAD WITH VAN NOZZLE
(REDUCE RADIUS TO ZERO)
AUTOMATIC CONTROLLER, WALL MOUNT INSIDE BUILDING.
INSTALL PER DETAIL.
WIRELESS RAIN/FREEZE SENSOR WITH MOUNTING BRACKET,
MOUNT ON ROOF PARAPET IN LOCATION SHOWN ON PLAN.
OPERATION WILL BE TESTED AT PUNCH LIST REVIEW.
APPROXIMATE LOCATION. SEE CVIIL DRAWINGS.
DOUBLE CHECK VALVE. INSTALL PER CITY STANDARD
DETAIL SHOWN ON CIVIL DRAWINGS.
200 PSI THREADED ENDS, BRONZE, SCREW IN BONNET,
NON -RISING STEM, SOLID WEDGE, INSTALL PER DETAIL.
INSTALL AT POINT OF CONNECTION AS PER DETAIL.
INSTALL AT POINT OF CONNECTION AS PER DETAILS.
INSTALL AT P.O.C. AND ELSEWHERE AS SHOWN ON
PLANS, AS PER DETAILS. PROVIDE (2) KEYS AND
(2) ELLS.
BRASS NORMALLY CLOSED MASTER CONTROL VALVE.
INSTALL AT P.O.C. ASSEMBLY PER DETAIL.
MEDIUM FLOW CONTROL ZONE KIT. MEDIUM FLOW KIT
INCLUDES BALL VALVE, PESB VALVE, AND
PRESSURE -REGULATING BASKET FILTER. INSTALL IN
APPROXIMATE LOCATION AS SHOWN ON PLAN AND DETAIL.
PLASTIC CONTROL VALVE WITH PRESSURE REGULATING
DIAL, INSTALL PER DETAIL.
BRONZE BALL VALVE, INSTALL PER DETAIL 'F', SHEET
L2.5, SEE SPECIFICATIONS, SIZE TO MATCH MAINLINE SIZE.
SEE SPECIFICATIONS FOR DETAILED REQUIREMENTS.
2-1/2" MINIMUM SIZE UNLESS NOTED OTHERWISE, SEE
SPECIFICATIONS FOR MINIMUM BURIAL DEPTH. SEE DETAIL.
SIZE AS PER PLAN, 3/4" MINIMUM. UNLABELED PIPE
SECTIONS TO MATCH THE LARGEST OF THE ADJACENT PIPES.
UNLABELED PIPE AT THE END OF LATERAL RUNS TO BE
3/4". SEE SPECIFICATIONS FOR MINIMUM BURIAL DEPTH.
SEE DETAIL.
UNDERPAVEMENT SLEEVING, 4" DIAMETER UNLESS OTHERWISE
INDICATED ON PLAN. TO BE INSTALLED BY LANDSCAPE
CONTRACTOR AT DEPTHS SPECIFIED. SEE DETAIL.
SUBSURFACE DRIPPERLINE WITH 12" O.C. EMITTER
SPACING WITH EMITTER DISCHARGE OF 0.6 GPH. INSTALL
TUBING ROWS AT APPROXIMATELY 16" to 18" SPACING
BETWEEN PARALLEL DRIPPER -LINE. ALL TUBING SHALL
BE INSTALLED 1" BELOW TOP OF TOPSOIL AND STAKED
WITH 6" STAKES AT 3' O.C. VERIFY THE LAYOUT AND
SPACING IN THE FIELD PRIOR TO STARTING THE WORK.
SUPPLY HEADER SIZE TO MATCH ADJACENT LATERAL LINE
(3/4" MINIMUM). EXHAUST HEADER SIZE SHALL BE 3/4"
MINIMUM. INSTALL IN LOCATIONS AS SHOWN ON PLAN.
PROVIDE AND INSTALL MANUAL FLUSH VALVE AT
END/MIDDLE OF DRIPLINE, CONNECT TO PVC EXHAUST
HEADER. INSTALL FLUSH VALVE INSIDE A SEPARATE
VALVE BOX, ONE AT THE END OF TUBING RUNS IN EACH
DIRECTION. INSTALL MINIMUM ONE FLUSH VALVE PER 1000
L.F. OF TUBING IN EACH DIRECTION, OR MINIMUM ONE PER
EACH PLANTING ISLAND AND EXHAUST HEADER. INSTALL
18" FROM PAVING. INSTALL IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS.
STAKE AT 3' O.C., PLUS TWO (2) ON EACH TEE, ELBOW
OR CROSS.
PROVIDE ONE PER DRIP ZONE, AT END OF LATERAL
LINE FROM VALVE, TO INDICATE ZONE IS IN OPERATION.
SYMBOL ITEM MANUFACTURER / CAT NO. DESCRIPTION -REMARKS
O 6*0 ki POP-UP FIELD ROTOR
O L Q L� Q POP-UP SPRAY HEAD
O Q 0 Q POP-UP SPRAY HEAD
5F 5H or 5Q POP-UP SPRAY HEAD
O �
SST EAST ❑LCS or R❑CS POP-UP SPRAY HEAD
Q BUBBLER
TORO
O NOZ
T7P-SS-02
#12 -
FULL PATTERN
(9.95 GPM)
:,*NOZ
#09
- 3/4 PATTERN
(7.5 GPM)
NOZ
#12 -
HALF PATTERN
(9.95 GPM)
kiNOZ
#07
- QUARTER PATTERN (6.81 GPM)
TORO 0-T-15-(x)-570Z-6P-PR
(X)=60, Q,
T,
150, H, 210, TQ OR
F
AS SHOWN
ON
PLAN.
TORO 0-T-12-(x)-570Z-6P-PR
(X)=60, Q,
T,
150, H, 210, TO OR
F
AS SHOWN
ON
PLAN.
TORO 0-T-10-(x)-570Z-6P-PR
(X)=60, Q,
T,
150, H, 210, TQ OR
F
AS SHOWN
ON
PLAN.
TORO 0-T-8-(x)-570Z-6P-PR
(X)=60, Q,
T,
150, H, 210, TQ OR
F
AS SHOWN
ON
PLAN.
TORO 0-T-5-(x)-570Z-6P-PR
(X)=60, Q,
T,
150, H, 210, TO OR
F
AS SHOWN
ON
PLAN.
TORO O-T-(z)-(x)-570Z-6P-PR
(z)=15 OR
30,
(x)=SST, RCS OR LCS
AS SHOWN
ON
PLAN.
TORO 514-20 ADJUSTABLE FLOOD BUBBLER
ON 570SR-18 RISER
IRRIGATION NOTES:
1. ADJUST ALL IRRIGATION HEADS TO PROVIDE MAXIMUM COVERAGE,
MINIMUM OVERSPRAY, AND NO FOGGING. SET ALL HEADS BACK
FROM CURBS, PAVING, AND WALLS.
2. LOCATION OF IRRIGATION MAINLINE, LATERALS, AND SLEEVING ARE
SCHEMATIC ONLY, AND SHALL OCCUR IN PLANTING AREAS UNLESS
SLEEVING IS SHOWN. IF SLEEVES ARE SHOWN THEY ARE TO BE
STRAIGHT RUNS, TYP. MAKE MINOR CHANGES TO COORDINATE
WITH ACTUAL AS -BUILT DIMENSIONS AND CONDITIONS.
3. VALVE BOXES SHALL BE LOCATED IN SHRUB PLANTING AREAS
ONLY. LOCATE IN APPROXIMATE LOCATIONS AS SHOWN ON PLAN.
4. SEE CIVIL PLANS FOR LOCATION OF IRRIGATION STUB -OUT FROM
2" METER.
5. ANTICIPATED AVAILABLE STATIC WATER PRESSURE IS 68 PSI, AS
PROVIDED BY CITY OF RENTON. VERIFY EXACT PRESSURE AT
POINT OF CONNECTION PRIOR TO START OF WORK.
6. THE IRRIGATION SYSTEM HAS BEEN DESIGNED WITH SEPARATE
HYDROZONES ACCORDING TO THE NEEDS OF THE PLANT MATERIAL.
THE IRRIGATION SYSTEM HAS BEEN DESIGNED TO PROVIDE A
MINIMUM AVERAGE DISTRIBUTION UNIFORMITY OF 0.625. THE
IRRIGATION SYSTEM HAS BEEN DESIGNED TO AVOID RUNOFF, LOW
HEAD DRAINAGE, AND OVERSPRAY. AVOID IRRIGATION DURING
TIMES OF HIGH WINDS, WHEN RAINING, OR DURING THE MIDDLE OF
THE DAY.
7. WHERE IRRIGATION PIPING IS SHOWN ADJACENT OR UNDER
EXISTING TREES, MAKE MINOR ROUTE ADJUSTMENTS TO AVOID
TRENCHING THROUGH LARGE TREE ROOTS. REFER TO
SPECIFICATION SECTION 02810 FOR FURTHER INSTRUCTIONS.
8. REFER TO IRRIGATION SPECIFICATION FOR ADDITIONAL
REQUIREMENTS.
FIELD SPORTS ROTOR WITH STAINLESS STEEL RISER
40 PSI ADJUST RADIUS AS REQUIRED.
30 PSI ADJUST RADIUS AS
REQUIRED,
INSTALL PER
DETAIL 'H', SHEET L-305.
USE TORO
0-T-15-(x)-57OZ-6P-PR-COM
WHERE REQUIRED TO
PREVENT LOW HEAD DRAINAGE.
30 PSI ADJUST RADIUS AS
REQUIRED,
INSTALL PER
DETAIL 'H', SHEET L-305.
USE TORO
0-T-12-(x)-57OZ-6P-PR-COM
WHERE REQUIRED TO
PREVENT LOW HEAD DRAINAGE.
30 PSI ADJUST RADIUS AS
REQUIRED,
INSTALL PER
DETAIL 'H', SHEET L-305.
USE TORO
0-T-10-(x)-570Z-6P-PR-COM
WHERE REQUIRED TO
PREVENT LOW HEAD DRAINAGE.
30 PSI ADJUST RADIUS AS
REQUIRED,
INSTALL PER
DETAIL 'H', SHEET L-305.
USE TORO
0-T-8-(x)-57OZ-6P-PR-COM
WHERE
REQUIRED TO
PREVENT LOW HEAD DRAINAGE.
30 PSI ADJUST RADIUS AS
REQUIRED,
INSTALL PER
DETAIL 'H', SHEET L-305.
USE TORO
0-T-5-(x)-57OZ-6P-PR-COM
WHERE
REQUIRED TO
PREVENT LOW HEAD DRAINAGE.
30 PSI ADJUST RADIUS AS
REQUIRED,
INSTALL PER
DETAIL 'H', SHEET L-305.
USE TORO
0-T-(z)-(x)-570Z-6P-PR-COM WHERE REQUIRED TO
PREVENT LOW HEAD DRAINAGE.
30 PSI, ADJUST RADIUS AS REQUIRED.
ZONE SUMMARY
ZONE
GPM
SIZE
PLANT
TYPE
1
12.0
1.5"
SHRUB
DRIP
2
43.7
1.5"
SHRUB
SPRAY
3
18.2
1"
SHRUB
SPRAY
4
49.8
1.5"
SHRUB
SPRAY
5
33.5
1.5"
LAWN
ROTOR
6
27.4
1.5"
LAWN
ROTOR
7
37.4
1.5"
LAWN
ROTOR
8
29.9
1.5"
LAWN
ROTOR
9
39.8
1.5"
LAWN
ROTOR
10
37.4
1.5"
LAWN
ROTOR
11
43.5
1.5"
LAWN
ROTOR
12
6.0
1"
TREE
BUBBLER
13
40.0
1.5"
1 SHRUB
SPRAY
14
32.2
1.5"
SHRUB
SPRAY
15
11.2
1.5"
SHRUB
SPRAY
16
48.9
1.5"
SHRUB
SPRAY
17
32.3
1.5"
SHRUB
SPRAY
18
37.0
1.5"
LAWN
ROTOR
19
36.6
1.5"
SHRUB
SPRAY
20
16.0
1"1
TREE
BUBBLER
21
SPARE WIRE
21
SPARE WIRE
R-393052
C
0
N N
O
1�
O O
v
LLJ
O
l
>
> O
e _
a =
e =
W
X
Z ¢
O
� e v
U
v
= W
Z
®
F
O
x
N W
J
O W
-F-
RECORD DRAWING
THE INFORMATION ON THIS DRAWING
INDICATES CHANGES MADE TO THE
CONSTRUCTION DOCUMENTS AS
RECORDED BY THE CONTRACTOR AND
TRANSFERRED TO THE REPRODUCIBLE
DRAWINGS BY THE ARCHITECT. THE
ARCHITECT ASSUMES NO RESPONSIBILITY
FOR THE ACCURACY OR RELIABILITY OF
THE INFORMATION PROVIDED.
o
N Z
IC, „all N 3
Z N
®w orn
Ljj W
m w
I'�NNI'9',II� N to
Q
W
W
a u
W gW
z<
<W
O
}i
O
■�
Ja
p
}�
O
a
E
W
O
}0
■_
L
a
p
L
Date: 10/16/19
Job No.: 21607.00
Drawn By: NIL
Checked by: NH
Revisions
# Date Description
IRRIGATION
LEGEND AND
NOTES
L303
RECORD DRAWING