Loading...
HomeMy WebLinkAboutR-393054SPECIFIED RECTANGULAR SPECIFIED RECTANGULAR VALVE BOX, INSTALL TOP OF VALVE BOX, INSTALL TOP OF LID FLUSH WITH FINISH GRADE LID FLUSH WITH FINISH GRADE RAINBIRD CONTROL ZONE KIT SPECIFIED AUTOMATIC AUTOMATIC CONTROL VALVE (SEE LEGEND FOR TYPE, 1" CONTROL VALVE, KIT FOR DRIP ZONES SIZE ZONE KIT DEPICTED) � - INSTALL PRESSURE (SEE LEGEND FOR TYPE) BASKET FILTER REGULATING DIAL IF SHOWN 19 ON LEGEND 24" SPARE WIRE FINISH GRADE COIL, SEE SPECS FINISH GRADE FOR QUANTITY SPECIFIED SPLICE KITS SPECIFIED SPLICE KITS USE BOTTOM INLET ONLY cn - 24" CONTROL WIRE cn 24" SPARE WIRE - 24" CONTROL WIRE oz z - COIL IN BOX z z PVC RISER, SAME COIL, SEE SPECS _ - ; - COIL IN BOX F- J Q PVC BALL VALVE - - J - INLINE PRESSURE o_ ---- SIZE AS INLET FOR QUANTITY J w Q REGULATOR u Q o PVC ADAPTER - 1" MIN. CLEARANCE o Li w < Q Q PVC ADAPTER 1" MINCLEARANCE c�'�`' J . PVC LATERAL 45, BURIAL DEPTH - BETWEEN VALVE BOX w o_ BETWEEN VALVE BOX w Q Q a- AND PIPE J � D AND PIPE J � PER SPECIFICATIOSN P P P FLOW wom P ♦ _ wom 3" MIN. - w'� � - 3" MIN. Lu LL- P CLR. - %p CLR. P ��� �� ���� P o 0 0 0 0 0 0 0 0 0 l PVC UNION J PROVIDE CORRECT SIZE NIPPLE SO THAT LATERAL LINE COMES RIGHT OUT OF THE BOX WITHOUT USING 90 DEG. ELLS OR 45 DEG. ELL. MAINLINE, SIZE PER PLAN CONTROL AND SPARE WIRES, TAPE TO BOTTOM OF MAINLINE ELEVATION VIEW NOTE: PROVIDE VALVE BOX EXTENSIONS AS REQUIRED. -,-,< PVC UNION -/ " 1� \ PROVIDE CORRECT SIZE PVC LATERAL PIPE NIPPLE SO THAT LATERAL LINE COMES RIGHT OUT OF SUPPORT VALVE BOX THE BOX WITHOUT USING 90 DEG. ELLS OR 45 DEG. ELL. WITH (4) BRICKS MAINLINE, SIZE PER PLAN MINIMUM 2 C.F. (12" DEPTH) CONTROL AND SPARE WIRES, DRAIN ROCK SUMP IN TAPE TO BOTTOM OF MAINLINE BOTTOM OF VALVE BOX. ELEVATION VIEW N OTE: PROVIDE VALVE BOX EXTENSIONS AS REQUIRED. REMOTE CONTROL VALVE (SPRAY ZONES LVIN. M.&M NOTES: IF1. ALL DRIPPERLINE TO BE INSTALLED 1" BELOW TOP OF TOPSOIL LEVEL. 2. MULTIPLE ROWS OF DRIPLINE SHALL BE SPACED AT 18" MAXIMUM O.C. ADJUST ACTUAL SPACING TO PROVIDE AN EVEN SPACING ACROSS THE PLANTED AREA. 3. COORDINATE AND PLACE ALL PLANTINGS SO THAT DRIPPERLINES RUN OVER TOP OF ALL ROOTBALLS. MINIMUM OF 1 PER GROUNDCOVER, 2 PER 5-GALLON SHRUB, 2 PER TREE. 4. ALL TREES TO BE PLANTED WITHIN CENTER OF DRIPPERLINE RUNS. 5. LAYOUT DRIPLINE SO THAT OUTLETS ARE TRIANGULAR SPACED. 6. MAKE MINOR ADJUSTMENTS IN SUPPLY HEADER, EXHAUST HEADER, AND DRIPLINE LAYOUT TO AVOID CONFLICTS WITH LIGHT POLES, FIRE HYDRANTS, AND OTHER MISC. IMPROVEMENTS. 7. WHERE REMOTE CONTROL VALVE IS SHOWN WITHIN PARKING LOT ISLAND, IT SHALL BE LOCATED AT MID POINT OF ISLAND, ADJACENT TO PARKING STALLS. 8. SEE IRRIGATION NOTES, LEGENDS, AND SPECIFICATIONS FOR ADDITIONAL INFORMATION L PLAN VIEW TYPICAL DRIP IRRIGATION LAYOUT Scale: 1 1 /2"=V-0" PVC LATERAL WITH SLEEVE (SEE PLAN FOR SIZES) EXHAUST HEADER, LOCATE WHERE SHOWN ON PLAN AT LOWER END OF EACH PLANTING ISLAND MANUAL LINE FLUSHING VALVE (PLUMBED TO EXHAUST HEADER), OFFSET 18" FROM EDGE OF BED DOUBLE RING DRIPPERLINE AT EACH TREE ROOTBALL (COORDINATE WITH LANDSCAPE PLAN FOR TREE LOCATIONS) INSTALL FIRST DRIPPERLINE 4"-6" FROM EDGE OF WALK OR CURB SUPPLY HEADER, CENTER FEED WITH DRIPPERLINE BLANK RISERS, LOCATE WHERE SHOWN ON PLAN 16" TO 18" TYPICAL DRIPPERLINE SPACING, PROVIDE NUMBER OF LINES SHOWN ON PLAN ROUTE PVC LATERAL AND/OR MAINLINE ALONG CURB TO AVOID TREE AND SHRUB ROOTBALLS (COORDINATE WITH PLANTING PLAN) PVC LATERAL WITH SLEEVE (SEE PLAN FOR SIZES) Scale: 3/16"=1'-O" PVC LATERAL PIPE SUPPORT VALVE BOX WITH (4) BRICKS MINIMUM 2 C.F. (12" DEPTH) DRAIN ROCK SUMP IN BOTTOM OF VALVE BOX. REMOTE CONTROL VALVE (DRIP ZONES ROUTE DRIPPERLINI ON TOP OF SHRUB OR GROUNDCOVER ROOT BALL Scale: 1 1 /2"=V-0" DRIPPERLINES, TYP. SHRUB TREE ROOT BALL ROOT BALL i I � DOUBLE RING DRIPPERLINE AT EACH TREE LOCATION, WITH \ FITTINGS AS REQUIRED. \ ROUTE ONE LINE ON \ TOP OF TREE ROOT BALL AND SECOND LINE OUTSIDE OF ROOT BALL. SOIL, MALE ADAPTER TEE OR ELL 6" SPACING SPACING PER LEGEND PER LEGEND 6" OFFSET FROM EDGE OF ADJACENT PAVING OR BED, UNLESS OTHERWISE NOTED ON PLAN PLAN VIEW HEADER, END FEED CONDITION (SUPPLY OR EXHAUST) SPACING PER LEGEND TYPICAL DRIP HEADER INSTALLATION NOTES: 1. TEMPORARILY CAP RISERS FOR PRESSURE TESTING. ELEVATION VIEW 2. SEAL ALL JOINTS W/ TEFLON TAPE ON MALE THREADS ONLY. 3. DO NOT OVERTIGHTEN GALV. TO PVC JOINTS. 4. ALL THREADED PVC PIPE SHALL BE SCH. 80, ALL PVC FITTINGS SHALL BE SCH. 40. 5. NO CLOSE NIPPLES PERMITTED. 6. ALL FITTINGS AND PIPE SAME DIA. AS IPS FEMALE CONNECTION OF SPRINKLER HEAD OR Q.C. 7. INSTALL SO PIPING WILL NOT CONTACT LATERAL. PLAN VIEW IRRIGATION HEAD FINISH GRADE MULCH (DEPTH AS SPECIFIED) TOP OF TOPSOIL 4" MAXIMUM = 1" BELOW w TOP OF TO o DRIPPERLINE, TYP. - z TRENCH PRIOR TO P MULCH. ADJUST OUT N MAXIMIZE ROOTBALL SOIL STAPLE AT 3' MALE ADAPTER TEE OR ELL AT HEA SECTION VIEW OF HEADER END FEED CONDITION TOP INSTALL IN LACEMENT OF LETS TO SATURATION. O.C. MAX. DER FINISH GRADE MULCH (DEPTH AS SPECIFIED) TOP OF TOPSOIL 4" MAXIMUM = 1" BELOW TOP OF TOPSOIL w 0 DRIPPERLINE, TYP. - INSTALL IN z TRENCH PRIOR TO PLACEMENT OF MULCH. ADJUST OUTLETS TO N MAXIMIZE ROOTBALL SATURATION. SOIL STAPLE AT 3' O.C. MAX. AND ON EACH SIDE OF ALL CONNECTIONS DRIPPERLINE TEE DRIPPERLINE BLANK RISER MALE ADAPTER SECTION VIEW OF TEE OR ELL AT HEADER CENTER FEED CONDITION HEADER Scale: 1 1 /2"=1'-0" SHRUB OR LAWN HEAD TOP FLUSH W/ FINISH GRADE FINISH GRADE (2) TH x TH SCH. 40 ELLS W/ 2" x 3/4" SCH. 80 NIPPLE OR (2) MARLEX STREET ELLS W/O NIPPLE 12" x 3/4" SCH. 80 NIPPLE SCH. 40 TH x TH ELL, OR MARLEX STREET ELL PVC TEE OR ELL, BUSHING AS REQUIRED VC TEE OR ELL, WITH USHING AS REQUIRED VC TH SCH. 80 IPPLE, 3" LONG VC THx TH 90° ELL VC TH SCH. 80 NIPPLE, " LONG Scale: 3"=1'-0" CD w X Q z. R-393054 BUBBLER HEAD SPECIFIED NOZZLE AND RISER ASSEMBLY FINISH GRADE SCHEDULE 80 NIPPLE PVC TEE OR ELL, BUSHING AS REQUIRED. PVC LATERAL PIPE Scale: 1-1 /2"=1'-O" C 0 N N O 1� O O v LLJ O l > > O e _ a = e = W X Z ¢ O � e v U v = W Z ® F O x N w J O w -r RECORD DRAWING THE INFORMATION ON THIS DRAWING INDICATES CHANGES MADE TO THE CONSTRUCTION DOCUMENTS AS RECORDED BY THE CONTRACTOR AND TRANSFERRED TO THE REPRODUCIBLE DRAWINGS BY THE ARCHITECT. THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR THE ACCURACY OR RELIABILITY OF THE INFORMATION PROVIDED. }i O ■� Ja }� p }� O j 0 E C a W O }i ■_ L p L Cn Date: 10/16/19 Job No.: 21607.00 Drawn By: NL Checked by: NH Revisions # Date Description IRRIGATION DETAILS L305 RECORD DRAWING