Loading...
HomeMy WebLinkAboutP_Construction_Plans_191211_v1 1110 112th Avenue NE, Suite 202, Bellevue WA 98004 | PHONE: 425-646-4022 | FAX 425-646-4024 | MAINVUEHOMES.COM Framing List for Code compliance MainVue homes to meet 2a Energy code requirements. · Subcontractor shall provide and install foam backer rod of proper size around all windows, exterior doors and other such gaps. These locations shall receive an application of low expansion foam on top of the backer rod · All foam used shall be low expansion type. Any bowing, warping or movement caused by the application of foam shall be repaired at the Subcontractors expense. · Subcontractor shall run a bead of sealant on the interior of all exterior plate lines and inside corners · Subcontractor shall foam all penetrations including but not limited to plumbing and electrical. · Subcontractor shall insulate all water pipes in crawl space and garage situations, per Washington State Energy Code. · Subcontractor shall insulate all exposed waterlines in garage including but limited too: Garage Hose-Bib Shut-Off Valve, Waterlines to Tankless Heater, and Main Water Supply. All gaps and corners to be fully wrapped so no piping is exposed. o Pipe Insulation shall not have joints larger than an 1/8” and shall be covered with duct tape when they occur. Zip Ties can be substituted for duct tape to seal and keep foam insulation in place. · Subcontractor shall seal all penetrations through drywall in the garage with Intumescent Firestop Caulking. · 2015 Energy Code o To help meet 2015 blower door test the following shall be done, o 2nd Floor Gasket Sill Sealer at the upper plate between each room opening as it meets the upper plate. o To include outside plate at the outside wall o Attic Air Seal through Can lights and fixtures going through the attic o Caulking is to prevent air flow from upper roof to lower room o Caulking is to be done from the attic before blown insulation is placed or installed o Caulking all open penetration at this so there is an air seal and not gap at the all upper cans o o COVER SHEETA0.0 BALMAINE 'N' (51-40-01) DESIGN: SU DRAWN: TD SHEET1110 112th Ave NE, Suite 202Bellevue, WA 98004Phone: (425) 646-4022Fax: (425) 646-4024DESCRIPTIONDATENo.321- PLAN No:BALMAINE 'N'(51-40-01)422x34 - 1 4" = 1'-0" 11x17 - 18" = 1'-0"WA,51-40-01 N ALU-47 CUSTOM· · · · · · · · · · · · · MAIN FLOORPLANDESIGN: SU DRAWN: JZ SHEET1110 112th Ave NE, Suite 202Bellevue, WA 98004Phone: (425) 646-4022Fax: (425) 646-4024DESCRIPTIONDATENo.321- PLAN No: 51-40-01.02.0 NBALMAINE 'N'(51-40-01.02.0)422x34 - 1 4" = 1'-0" 11x17 - 18" = 1'-0"WA,ALU-47 CUSTOMA2.0 FLOORPLANOPTIONSA2-OPT DESIGN: SU DRAWN: TD SHEET1110 112th Ave NE, Suite 202Bellevue, WA 98004Phone: (425) 646-4022Fax: (425) 646-4024DESCRIPTIONDATENo.321- PLAN No:BALMAINE 'N'(51-40-01)422x34 - 1 4" = 1'-0" 11x17 - 18" = 1'-0"WA,51-40-01 N ALU-47 CUSTOM UPPER FLOORPLANDESIGN: SU DRAWN: JZ SHEET1110 112th Ave NE, Suite 202Bellevue, WA 98004Phone: (425) 646-4022Fax: (425) 646-4024DESCRIPTIONDATENo.321- PLAN No: 51-40-01.02.0 NBALMAINE 'N'(51-40-01.02.0)422x34 - 1 4" = 1'-0" 11x17 - 18" = 1'-0"WA,ALU-47 CUSTOMA4.0 ROOF PLANDESIGN: SU DRAWN: JZ SHEET1110 112th Ave NE, Suite 202Bellevue, WA 98004Phone: (425) 646-4022Fax: (425) 646-4024DESCRIPTIONDATENo.321- PLAN No: 51-40-01.02.0 NBALMAINE 'N'(51-40-01.02.0)422x34 - 1 4" = 1'-0" 11x17 - 18" = 1'-0"WA,ALU-47 CUSTOMA5.0 DATENo.3214BALMAINE 'N'(51-40-01.02.0)FRONT ELEVATIONELEVATIONFEATUREMATERIALLEGENDFEAURE MATERIAL CHOICEBALMAINE - NFOR ILLUSTRATIVE PURPOSES ONLY. SUBJECT TO SELLER’S ADDENDUM TO RESIDENTIAL REAL ESTATE PURCHASE AND SALES AGREEMENT. SITE CONDITIONS AND/OR PLAN OPTIONS NOT REFLECTED.WA,LLCRIGHTLEDGESTONE1CAST STONE3BRICK2TILE4ALU-47 LEAF BODY 1: FAWN BRINDLE SW7640 BODY 2: ANONYMOUS SW7046 ACCENT: SEALSKIN SW7675 SIDES AND REAR: FAWN BRINDLE SW7640 ENTRY SOFFIT: FAWN BRINDLE SW7640 OUTDOOR ROOM SOFFIT: CITY LOFT SW7631 TRIM: CITY LOFT SW7631 FRONT DOOR STAIN: SW-MAINVUE PAINT BRUSH GARAGE DOOR: ANONYMOUS SW7046 NOTE: All exterior paint is A-100 Low SheenSTONE BLOCK: MARQUEE 24, DOVE TAILMETAL COPING: SANDLeaf ROOF (Allura ONLY):Weatherwood EXTERIORELEVATIONSA6.0 DESIGN: SU DRAWN: JZ SHEET1110 112th Ave NE, Suite 202Bellevue, WA 98004Phone: (425) 646-4022Fax: (425) 646-4024DESCRIPTIONDATENo.321- PLAN No: 51-40-01.02.0 NBALMAINE 'N'(51-40-01.02.0)422x34 - 1 4" = 1'-0" 11x17 - 18" = 1'-0"WA,ALU-47 CUSTOMW:\Seattle\Plan Library\MainVue Plans\40ft Product\51-40 BALMAINE\CAD Files\00 Base Plan\ELEV N - ALU-47\51-40-01 N - ALU-47.dwg, 12/11/2019 11:50:14 AM, tom.diseth SIDINGENHANCEMENTSA6-DTL DESIGN: SU DRAWN: JZ SHEET1110 112th Ave NE, Suite 202Bellevue, WA 98004Phone: (425) 646-4022Fax: (425) 646-4024DESCRIPTIONDATENo.321- PLAN No: 51-40-01.02.0 NBALMAINE 'N'(51-40-01.02.0)422x34 - 1 4" = 1'-0" 11x17 - 18" = 1'-0"WA,ALU-47 CUSTOM FEATUREMATERIAL:CAST STONE (3)A9.0 DESIGN: SU DRAWN: TD SHEET1110 112th Ave NE, Suite 202Bellevue, WA 98004Phone: (425) 646-4022Fax: (425) 646-4024DESCRIPTIONDATENo.321- PLAN No:BALMAINE 'N'(51-40-01)422x34 - 1 4" = 1'-0" 11x17 - 18" = 1'-0"WA,51-40-01 N ALU-47 CUSTOM ELEVATIONSPECIFICDETAILSA9.1 DESIGN: SU DRAWN: TD SHEET1110 112th Ave NE, Suite 202Bellevue, WA 98004Phone: (425) 646-4022Fax: (425) 646-4024DESCRIPTIONDATENo.321- PLAN No:BALMAINE 'N'(51-40-01)422x34 - 1 4" = 1'-0" 11x17 - 18" = 1'-0"WA,51-40-01 N ALU-47 CUSTOM A11.0INTERIOR ELEVATIONS & DETAILSDESIGN:SUDRAWN:JZSHEET1110 112th Ave NE, Suite 202 Bellevue, WA 98004 Phone: (425) 646-4022 Fax: (425) 646-4024 DESCRIPTIONDATENo. 3 2 1 -PLAN No:BALMAINE (51-40-01) 422x34 - 14" = 1'-0"11x17 - 18" = 1'-0"WA,LLC51-40-01 A12.0TILE AND PANTRY LAYOUTSDESIGN:SUDRAWN:JZSHEET1110 112th Ave NE, Suite 202 Bellevue, WA 98004 Phone: (425) 646-4022 Fax: (425) 646-4024 DESCRIPTIONDATENo. 3 2 1 -PLAN No:BALMAINE (51-40-01) 422x34 - 14" = 1'-0"11x17 - 18" = 1'-0"WA,LLC51-40-01W:\Seattle\Plan Library\MainVue Plans\40ft Product\51-40 BALMAINE\CAD Files\00 Base Plan\BALMAINE (51-40-01) Supplimentary Diagrams.dwg, 6/22/2018 1:53:27 PM, Jennifer.Zanzig MULTI-STORYDETAILSDESIGN: -- DRAWN: -- SHEET1110 112th Ave NE, Suite 202Bellevue, WA 98004Phone: (425) 646-4022Fax: (425) 646-4024DESCRIPTIONDATENo.- PLAN No: DETAIL SHEETSSTANDARD DETAILS22x34 - 14" = 1'-0" 11x17 - 18" = 1'-0"WA,D1.0123 4 STANDARD PLANDETAILSDESIGN: -- DRAWN: -- SHEET1110 112th Ave NE, Suite 202Bellevue, WA 98004Phone: (425) 646-4022Fax: (425) 646-4024DESCRIPTIONDATENo.- PLAN No: DETAIL SHEETSSTANDARD DETAILS22x34 - 1 4" = 1'-0" 11x17 - 18" = 1'-0"WA,LLCD1.1123 4W:\Seattle\Plan Library\MainVue Plans\STANDARD DRAWING SHEETS\03 CAD\D1.0 - Detail Sheet.dwg, 11/7/2018 10:02:57 AM, anthony.leafty OUTDOOR ROOM FIREBOX OPT. & DETAILSD3.2-DESIGN:SUDRAWN:TDSHEET-PLAN No:- - -HALF-HEIGHT VERSIONS OUTDOOR ROOM OPT. FIREPLACE 1 W:\Seattle\Plan Library\MainVue Plans\STANDARD DRAWING SHEETS\03 CAD\D3.2 - D3.3 - D3.4 - Outdoor Stairs, Fireplaces and Pergola.dwg, 5/19/2017 2:23:50 PM, Linda.Kaminski STAIR DETAILSD3.4-DESIGN:SUDRAWN:TDSHEET-PLAN No:- - -EXTERIOR STAIR DETAILS OUTDOOR ROOM W:\Seattle\Plan Library\MainVue Plans\STANDARD DRAWING SHEETS\03 CAD\D3.2 - D3.3 - D3.4 - Outdoor Stairs, Fireplaces and Pergola.dwg, 4/27/2017 2:31:00 PM, Linda.Kaminski GENERAL STRUCTURAL NOTES THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE DRAWINGS CRITERIA STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. PRIMARY STRUCTURAL ELEMENTS NOT DIMENSIONED ON THE STRUCTURAL PLANS AND DETAILS SHALL BE LOCATED BY THE ARCHITECTURAL PLANS AND DETAILS. VERTICAL DIMENSION CONTROL IS DEFINED BY THE ARCHITECTURAL WALL SECTIONS, BUILDING SECTIONS, AND PLANS. DETAILING AND SHOP DRAWING PRODUCTION FOR STRUCTURAL ELEMENTS WILL REQUIRE DIMENSIONAL INFORMATION CONTAINED IN BOTH ARCHITECTURAL AND STRUCTURAL DRAWINGS. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. CONFORM TO ASCE 37-02 "DESIGN LOADS ON STRUCTURES DURING CONSTRUCTION." CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE CONTRACTORS WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES TO THE OWNER, CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. CONTRACTOR-INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. ALL STRUCTURAL SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD ERECTED SHALL BE SUPERVISED BY THE SUPPLIER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE AND ERECTION IN ACCORDANCE WITH INSTRUCTIONS PREPARED BY THE SUPPLIER. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: FOOTINGS AND OTHER UNFORMED SURFACES CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#6 BARS OR LARGER) FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#5 BARS OR SMALLER) COLUMN TIES OR SPIRALS AND BEAM STIRRUPS SLABS AND WALLS (INT FACE) 2000 PSF 50 PCF/35 PCF 0.35 3" 2" 1-1/2" 1-1/2" GREATER OF BAR DIAMETER PLUS 1/8" OR 3/4" ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC)(2015 EDITION). DESIGN LOADING CRITERIA FLOOR LIVE LOAD (RESIDENTIAL) DECK LIVE LOAD WIND EARTHQUAKE LATERAL SYSTEM: LIGHT FRAMED SHEAR WALLS SDC D, Ie=1.0, Ss=1.60, S1=0.50, Sds=1.067, Sd1=0.50, Cs=0.164, R=6.5, SEISMIC DESIGN BASE SHEAR Vsx=18.4 KIPS 40 PSF 60 PSF METHOD - DIRECTIONAL PROCEDURE Kzt=1.0, GCpi=0.18, 110 MPH (RISK CATEGORY II), EXPOSURE "B" ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE ALLOWABLE SOIL PRESSURE AND LATERAL EARTH PRESSURE ARE ASSUMED AND THEREFORE MUST BE VERIFIED BY A QUALIFIED SOILS ENGINEER OR APPROVED BY THE BUILDING OFFICIAL. FOUNDATION DESIGN IS BASED ON THE ASSUMED DESIGN VALUES LISTED BELOW. WHERE APPLICABLE, REFER TO SOILS REPORT IF ASSUMED DESIGN VALUES ARE GREATER THAN THE TYPICAL ASSUMED VALUES OF THE LOCAL JURISDICTION. IF SOILS ARE FOUND TO BE OTHER THAN ASSUMED OR GIVEN IN THE SOILS REPORT, NOTIFY THE STRUCTURAL ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST 18" BELOW ADJACENT FINISHED GRADE. FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS ABOVE, UNO. BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE. REFER TO SOILS REPORT, WHERE APPLICABLE. ALLOWABLE SOIL PRESSURE LATERAL EARTH PRESSURE (RESTRAINED/UNRESTRAINED) COEFFICIENT OF FRICTION 7. 1. 2. 3. 4. 5. 6. 8. 9. 10. 14. GEOTECHNICAL CONCRETE REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1), GRADE 60, fy = 60 KSI. EXCEPTIONS: ANY BARS SPECIFICALLY SO NOTED ON THE DRAWINGS SHALL BE GRADE 40, fy = 40 KSI. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A1064. SPIRAL REINFORCEMENT SHALL BE DEFORMED WIRE CONFORMING TO ASTM A615, GRADE 60, fy = 60 KSI. 12. DETAILING OF REINFORCING STEEL (INCLUDING HOOKS AND BENDS) SHALL BE IN ACCORDANCE WITH ACI 315-99 AND 318-14. LAP ALL CONTINUOUS REINFORCEMENT #6 AND SMALLER 48 BAR DIAMETERS OR 2'-0" MINIMUM. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP CORNER BARS #5 AND SMALLER 48 BAR DIAMETERS OR 2'-0" MINIMUM. LAPS OF LARGER BARS SHALL BE MADE IN ACCORDANCE WITH ACI 318-14, CLASS B. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. 13. SNOW 25 PSF CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH ACI 318 AND ACI 301, INCLUDING TESTING PROCEDURES. CONCRETE SHALL ATTAIN A 28-DAY STRENGTH OF f'c = 3000 PSI. SLUMP OF CONCRETE SHALL NOT EXCEED 6". STRUCTURAL DESIGN IS BASED ON A CONCRETE STRENGTH OF f'c = 2500 PSI, THEREFORE NO CONCRETE STRENGTH TESTING REQUIRED. ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR-ENTRAINED WITH AN AIR-ENTRAINING AGENT CONFORMING TO ASTM C260, C494, AND C618. TOTAL AIR CONTENT FOR FROST-RESISTANT CONCRETE SHALL BE IN ACCORDANCE WITH ACI 318-14, TABLE 19.3.3.1. 11 PREFABRICATED CONNECTOR PLATE WOOD ROOF TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER IN ACCORDANCE WITH THE "NATIONAL DESIGN STANDARD FOR METAL PLATE- CONNECTED WOOD TRUSS CONSTRUCTION, ANSI/TPI 1" BY THE TRUSS PLATE INSTITUTE FOR THE SPANS AND CONDITIONS SHOWN ON THE PLANS. LOADING SHALL BE AS FOLLOWS: TOP CHORD LIVE LOAD TOP CHORD DEAD LOAD BOTTOM CHORD DEAD LOAD TOTAL LOAD WIND UPLIFT (TOP CHORD) BOTTOM CHORD LIVE LOAD (BOTTOM CHORD LIVE LOAD DOES NOT ACT CONCURRENTLY WITH THE ROOF LIVE LOAD) TRUSSES SHALL BE DESIGNED TO NOT ALLOW LIMITED STORAGE PER IBC TABLE 1607.1. WEBS SHALL BE CONFIGURED SO THAT ALL OPENINGS ARE SMALLER THAN 24" WIDE x 42" HIGH. HEAVY DUTY THREADED CONCRETE ANCHORS SPECIFIED ON THE DRAWINGS SHALL BE "TITEN HD SCREW ANCHOR" AS MANUFACTURED BY THE SIMPSON STRONG TIE COMPANY. INSTALL IN STRICT ACCORDANCE WITH ICC-ES REPORT ESR-2713, INCLUDING MINIMUM EMBEDMENT AND EDGE DISTANCE REQUIREMENTS. SUBSTITUTIONS PROPOSED BY THE CONTRACTOR SHALL BE SUBMITTED FOR REVIEW WITH ICC REPORTS INDICATING EQUIVALENT OR GREATER LOAD CAPACITIES. 25 PSF 8 PSF 7 PSF 40 PSF 10 PSF 10 PSF PREFABRICATED PLYWOOD WEB JOIST DESIGN SHOWN ON PLANS IS BASED ON JOISTS MANUFACTURED BY THE TRUS-JOIST CORPORATION. ALTERNATE PLYWOOD WEB JOIST MANUFACTURERS MAY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND STRUCTURAL ENGINEER. ALTERNATE JOIST HANGERS AND OTHER HARDWARE MAY BE SUBSTITUTED FOR ITEMS SHOWN PROVIDED THEY HAVE ICC APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. ALL JOIST HANGERS AND OTHER HARDWARE SHALL BE COMPATIBLE IN SIZE WITH EPOXY-GROUTED ITEMS (THREADED RODS OR REINFORCING BAR) SPECIFIED ON THE DRAWINGS SHALL BE INSTALLED USING "SET-XP" EPOXY ADHESIVE AS MANUFACTURED BY THE SIMPSON STRONG TIE COMPANY. INSTALL IN STRICT ACCORDANCE WITH ICC-ES REPORT ESR-2508. SUBSTITUTIONS PROPOSED BY THE CONTRACTOR SHALL BE SUBMITTED FOR REVIEW WITH CURRENT ICC REPORTS INDICATING EQUIVALENT OR GREATER LOAD CAPACITIES. SPECIAL INSPECTION OF INSTALLATION IS REQUIRED. RODS SHALL BE ASTM A36, UNO. EXPANSION BOLTS INTO CONCRETE AND CONCRETE MASONRY UNITS SHALL BE "STRONG-BOLT 2" ANCHORS AS MANUFACTURED BY THE SIMPSON STRONG TIE COMPANY. INSTALL IN STRICT CONFORMANCE TO ICC-ES REPORT ESR-3037, INCLUDING MINIMUM EMBEDMENT AND EDGE DISTANCE REQUIREMENTS. SUBSTITUTIONS PROPOSED BY THE CONTRACTOR SHALL BE SUBMITTED FOR REVIEW WITH CURRENT ICC REPORTS INDICATING EQUIVALENT OR GREATER LOAD CAPACITIES. BOLTS INTO CONCRETE MASONRY OR BRICK MASONRY UNITS SHALL BE INTO FULLY GROUTED CELLS. SPECIAL INSPECTION OF INSTALLATION IS REQUIRED. 17. 15. 16. 18.. 19. 20. 21. 22. WOOD ANCHORAGE GLUED LAMINATED MEMBERS SHALL BE FABRICATED IN CONFORMANCE WITH ASTM AND ANSI/AITC STANDARDS. EACH MEMBER SHALL BEAR AN AITC OR APA-EWS IDENTIFICATION MARK AND SHALL BE ACCOMPANIED BY AN AITC OR APA-EWS CERTIFICATE OF CONFORMANCE. ALL GLULAM BEAMS SHALL BE DOUGLAS FIR COMBINATION 24F-V4, Fb = 2400 PSI, Fv = 265 PSI, E = 1800 KSI, UNO. ALL 24F-V8 GLULAM BEAMS WILL BE SPECIFIED ON PLAN AND SHALL BE DOUGLAS FIR COMBINATION 24F-V8, Fb = 2400 PSI, Fv = 265 PSI, E = 1800 KSI. GLUED LAMINATED COLUMNS SHALL BE DOUGLAS FIR COMBINATION 3, L2D GRADE, Fc = 2300 PSI, Fb = 2000 PSI, E = 1900 KSI. MANUFACTURED LUMBER, PSL, LVL, AND LSL, SHALL BE MANUFACTURED UNDER A PROCESS APPROVED BY THE NATIONAL RESEARCH BOARD. EACH PIECE SHALL BEAR A STAMP OR STAMPS NOTING THE NAME AND PLANT NUMBER OF THE MANUFACTURER, THE GRADE, THE NATIONAL RESEARCH BOARD NUMBER, AND THE QUALITY CONTROL AGENCY. ALL PSL, LVL, AND LSL LUMBER SHALL BE MANUFACTURED IN ACCORDANCE WITH ICC-ES REPORT ESR-1387 USING DOUGLAS FIR VENEER GLUED WITH A WATERPROOF ADHESIVE MEETING THE REQUIREMENTS OF ASTM D2559 WITH ALL GRAIN PARALLEL WITH THE LENGTH OF THE MEMBER. THE MEMBERS SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES: PSL (2.0E) LVL (2.0E) LSL (1.55E) PSL COLUMN (1.8E) DESIGN SHOWN ON PLANS IS BASED ON LUMBER MANUFACTURED BY THE TRUS-JOIST CORPORATION. ALTERNATE MANUFACTURERS MAY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND STRUCTURAL ENGINEER. ALTERNATE JOIST HANGERS AND OTHER HARDWARE MAY BE SUBSTITUTED FOR ITEMS SHOWN PROVIDED THEY HAVE CURRENT ICC APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. ALL JOIST HANGERS AND OTHER HARDWARE SHALL BE COMPATIBLE IN SIZE WITH MEMBERS PROVIDED. MANUFACTURED LUMBER PRODUCTS SHALL BE INSTALLED WITH A MOISTURE CONTENT OF 12% OR LESS. THE CONTRACTOR SHALL MAKE PROVISIONS DURING CONSTRUCTION TO PREVENT THE MOISTURE CONTENT OF INSTALLED BEAMS FROM EXCEEDING 12%. EXCESSIVE DEFLECTIONS MAY OCCUR IF MOISTURE CONTENT EXCEEDS THIS VALUE. Fb = 2900 PSI Fb = 2600 PSI Fb = 2325 PSI Fc = 2500 PSI E = 2000 KSI E = 2000 KSI E = 1550 KSI E = 1800 KSI Fv = 290 PSI Fv = 285 PSI Fv = 310 PSI Fv = 190 PSI ALL 2x LUMBER SHALL BE KILN DRIED OR MC-19, AND ALL LUMBER SHALL BE GRADED AND MARKED IN CONFORMANCE WITH WCLIB STANDARD GRADING RULES FOR WEST COAST LUMBER NO 17. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS AND BEAMS BEAMS POSTS PLATES AND MISC FRAMING (2x, 3x AND 4x MEMBERS) (6x AND LARGER) (4x MEMBERS) (6x AND LARGER) HEM-FIR NO 2 OR SPRUCE-PINE-FIR NO 2 HEM-FIR NO 2 OR SPRUCE-PINE-FIR NO 2 MINIMUM BASE VALUE, Fb = 850 PSI DOUGLAS FIR-LARCH NO 2 MINIMUM BASE VALUE, Fb = 875 PSI HEM-FIR NO 2 OR SPRUCE-PINE-FIR NO 2 MINIMUM BASE VALUE, Fc = 1100 PSI DOUGLAS FIR-LARCH NO 2 OR HEM-FIR NO 2 MINIMUM BASE VALUE, Fc = 575 PSI STUDS HEM-FIR STUD GRADE OR SPRUCE-PINE-FIR STUD GRADE MINIMUM BASE VALUE, Fc = 725 PSI WOOD TRUSSES SHALL UTILIZE APPROVED CONNECTOR PLATES (GANGNAIL OR EQUAL). SUBMIT SHOP DRAWINGS AND DESIGN CALCULATIONS TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION. SUBMITTED DOCUMENTS SHALL BE SIGNED AND STAMPED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF WASHINGTON. PROVIDE FOR SHAPES, BEARING POINTS, INTERSECTIONS, HIPS, VALLEYS, ETC, SHOWN ON THE DRAWINGS. EXACT COMPOSITION OF SPECIAL HIP, VALLEY, AND INTERSECTION AREAS, USE OF GIRDER TRUSSES, JACK TRUSSES, STEP-DOWN TRUSSES, ROOF OVER-FRAMING, ETC SHALL BE DETERMINED BY THE MANUFACTURER UNLESS SPECIFICALLY INDICATED ON THE PLANS. PROVIDE ALL TRUSS TO TRUSS AND TRUSS TO GIRDER TRUSS CONNECTION DETAILS AND REQUIRED CONNECTION MATERIALS. PROVIDE FOR ALL TEMPORARY AND PERMANENT ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE-TREATED WITH AN APPROVED PRESERVATIVE OR (2) LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER SHALL BE PROVIDED BETWEEN UNTREATED WOOD AND CONCRETE OR MASONRY. WOOD FASTENERS NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT NAIL SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION) FOR REVIEW AND APPROVAL. NAILS - PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTERSINKING PERMITTED. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG BOLTS BEARING ON WOOD. INSTALLATION OF LAG SCREWS SHALL CONFORM TO THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION (2015 EDITION) WITH A LEAD BORE HOLE OF 60-70% OF THE SHANK DIAMETER. LEAD HOLES ARE NOT REQUIRED FOR 3/8" AND SMALLER LAG SCREWS. BOLT HOLES SHALL BE A MINIMUM OF 1/32" TO A MAXIMUM OF 1/16" LARGER THAN THE BOLT DIAMETER. HOLES SHALL BE ACCURATELY ALIGNED IN MAIN MEMBERS AND SIDE PLATES/ MEMBERS. BOLTS SHALL NOT BE FORCIBLY DRIVEN. TIMBERLOK AND LEDGERLOK FASTENERS CALLED OUT BY LETTERS AND NUMBERS SHALL BE FASTEN- MASTER STRUCTURAL WOOD SCREWS MANUFACTURED AND INSTALLED IN STRICT ACCORDANCE WITH ICC-ES REPORT ESR-1078. WS SERIES WOOD SCREWS CALLED OUT ON PLAN SHALL BE "USP" WOOD SCREWS, AND INSTALLED IN STRICT ACCORDANCE WITH ICC-ES REPORT ESR-2761 PER THE "USP" STRUCTURAL CONNECTORS CATALOG ABOVE. EQUIVALENT SCREWS BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC-ES APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. LAG SCREWS ARE NOT AN EQUIVALENT SUBSTITUTION. WOOD FRAMING NOTES - THE FOLLOWING APPLY UNLESS NOTED OTHERWISE ON THE PLANS: SIZE 8d 10d 12d TYPE COMMON GUN GUN LENGTH 2-1/2" 3" 3-1/4" DIAMETER 0.131" 0.131" 0.131" 24. 27. A. B. C. A. PLYWOOD SHEATHING SHALL BE GRADE C-D, EXTERIOR GLUE OR STRUCTURAL II, EXTERIOR GLUE IN CONFORMANCE WITH DOC PS-1 OR PS-2. ORIENTED STRAND BOARD OF EQUIVALENT THICKNESS, EXPOSURE RATING AND PANEL INDEX MAY BE USED IN LIEU OF PLYWOOD. WALL SHEATHING SHALL BE 7/16" or 1/2" (NOMINAL) WITH SPAN RATING 24/0 FLOOR SHEATHING SHALL BE 3/4" T&G (NOMINAL) WITH SPAN RATING 48/24 ROOF SHEATHING SHALL BE 1/2" or 7/16" (NOMINAL) WITH SPAN RATING 32/16 REFER TO WOOD FRAMING NOTES BELOW FOR TYPICAL NAILING REQUIREMENTS. 23. 25. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE IBC, THE AITC "TIMBER CONSTRUCTION MANUAL", AND THE AF&PA "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION". MINIMUM NAILING, SHALL CONFORM TO TABLE 2304.10.1. OF THE IBC, UNO. COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH ARCHITECTURAL AND MECHANICAL DRAWINGS. WALL FRAMING: REFER TO ARCHITECTURAL DRAWINGS FOR THE SIZE OF ALL WALLS. ALL STUDS SHALL BE SPACED AT 16"oc, UNO. (2)STUDS MINIMUM SHALL BE PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS, AND AT BEAM OR HEADER BEARING LOCATIONS. (2)2x8 HEADERS SHALL BE PROVIDED OVER ALL OPENINGS IN STRUCTURAL WALLS, UNO. NAIL MULTI-MEMBER HEADERS WITH (2)ROWS 10d AT 12"oc. SOLID BLOCKING FOR WOOD COLUMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. PROVIDE CONTINUOUS SOLID BLOCKING AT MID-HEIGHT OF ALL STUD WALLS OVER 10'-0" IN HEIGHT. B. 28. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "USP" STRUCTURAL CONNECTORS, AS SPECIFIED IN THEIR 2015-2016 EDITION PRODUCT CATALOG. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE CURRENT ICC APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ALL 2x JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "JUS" OR "JL" SERIES JOIST HANGERS. ALL I-JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "THF" SERIES JOIST HANGERS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS OR BOLTS IN EACH MEMBER. ALL SHIMS SHALL BE SEASONED AND DRIED AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. 26. ABBREVIATIONS Ø AB ADDL ALT APPROX ARCH BLKG BM BOT C CLR CONT DF DP DS DWGS (E) EA EMBED EQ EQUIV EW EXP EXT FRMG FT FTG GA GALV GL L DIAMETER ANCHOR BOLT ADDITIONAL ALTERNATE APPROXIMATE ARCHITECT, BLOCKING BEAM BOTTOM CENTERLINE CLEARANCE CONTINUOUS DOUGLAS FIR DEEP, DEPTH DRAG STRUT DRAWINGS EXISTING EACH EMBEDMENT EQUAL EQUIVALENT EACH WAY EXPANSION EXTERIOR FRAMING FEET FOOTING GAUGE GALVANIZED GLUE LAMINATED ARCHITECTURAL TIMBER GR GT HD HDR HF HGR HORIZ IBC IRC L LBS LONG LSL LVL MAX MB MFR MIN MISC oc OPP OSB PLY PREFAB PSF GRADE GIRDER TRUSS HOLDOWN HEADER HEM FIR HANGER HORIZONTAL INTERNATIONAL BUILDING CODE INTERNATIONAL RESIDENTIAL CODE LENGTH POUNDS LONGITUDINAL LAMINATED STRUCTURAL LUMBER LAMINATED VENEER LUMBER MAXIMUM MACHINE BOLT MANUFACTURER MINIMUM MISCELLANEOUS ON CENTER OPPOSITE ORIENTED STRAND BOARD PLYWOOD PREFABRICATED POUNDS PER SQUARE FOOT HM HIP MASTER PSI PSL PT REQD SOG STD T&G THRD TPL TRANSV UNO VERT W w/ w/o WTS POUNDS PER SQUARE INCH PARALLEL STRAND LUMBER PRESSURE TREATED LUMBER REQUIRED SLAB ON GRADE SQUARE STANDARD SHEARWALL TONGUE AND GROOVE THREADED TRIPLE TRANSVERSE TYPICAL UNLESS NOTED OTHERWISE VERTICAL WIDE OR WIDTH WITH WITHOUT WELDED HEADED STUD WELDED THREADED STUD WELDED WIRE MESH REINF REINFORCING SQ SW TYP WHS WWM BOE BOTTOM OF EXCAVATION DBL DOUBLE HT HEIGHT JST K KP JOIST KIPS (1000 LBS) KING POST PLF POUNDS PER LINEAR FOOT NTS NOT TO SCALE NO NUMBER INT INTERIOR DN DOWN FDN FOUNDATION GWB GYPSUM WALLBOARD ±PLUS OR MINUS ALL WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END NAIL TOP PLATE AND BOTTOM PLATE TO EACH STUD WITH (3)10d NAILS. FACE NAIL DOUBLE TOP PLATES WITH 10d AT 12"oc AND LAP MINIMUM 4'-0" AT JOINTS AND PROVIDE (12)10d NAILS AT 4"oc EACH SIDE OF JOINT. AT TOP PLATE INTERSECTIONS PROVIDE (3)10d FACE NAILS. ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH (2)ROWS OF 12d NAILS AT 16"oc, OR ATTACHED TO CONCRETE BELOW WITH 5/8" DIAMETER ANCHOR BOLTS AT 4'-0"oc EMBEDDED 7" MINIMUM, UNO. THERE SHALL BE A MINIMUM OF (2)BOLTS PER PLATE SECTION WITH (1)BOLT LOCATED NOT MORE THAN 12" OR LESS THAN 4-1/2" FROM EACH END OF THE PLATE SECTION. INDIVIDUAL MEMBERS OF BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH (2)ROWS OF 10d AT 16"oc. UNLESS NOTED OTHERWISE, GYPSUM WALLBOARD SHALL BE FASTENED TO THE INTERIOR SURFACE OF ALL STUDS AND PLATES WITH #6 x 1-1/4" TYPE S OR W SCREWS AT 12"oc. UNLESS NOTED OTHERWISE, 7/16" OR 1/2" (NOMINAL) APA RATED SHEATHING (SPAN RATING 24/0) SHALL BE NAILED TO ALL EXTERIOR SURFACES WITH 8d NAILS AT 6"oc AT PANEL EDGES AND TOP AND BOTTOM PLATES (BLOCK UN-SUPPORTED EDGES) AND TO ALL INTERMEDIATE STUDS AND BLOCKING WITH 8d NAILS AT 12"oc. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND PANEL ENDS. FLOOR AND ROOF FRAMING: PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND OVER MORE THAN HALF THE JOIST LENGTH AND AROUND ALL OPENINGS IN FLOORS OR ROOFS, UNO. PROVIDE SOLID BLOCKING AT ALL BEARING POINTS. TOENAIL TIMBER JOISTS TO SUPPORTS WITH (3)10d NAILS AND NAIL TJI JOISTS TO SUPPORTS WITH (2)10d NAILS. ATTACH JOISTS TO BEAMS WITH JOIST HANGERS IN ACCORDANCE WITH NOTES ABOVE. NAIL ALL MULTI-JOIST BEAMS TOGETHER WITH (2)ROWS 10d AT 12"oc. TOENAIL RIM JOIST TO TOP PLATE WITH 10d AT 6"oc. TOENAIL BLOCKING BETWEEN JOISTS TO TOP PLATE WITH (3)10d NAILS. UNLESS NOTED OTHERWISE ON THE PLANS, PLYWOOD ROOF AND FLOOR SHEATHING SHALL BE LAID UP WITH GRAIN PERPENDICULAR TO SUPPORTS AND NAILED AT 6"oc WITH 8d NAILS TO FRAMED PANEL EDGES, STRUTS AND OVER STUD WALLS AS SHOWN ON PLANS AND AT 12"oc TO INTERMEDIATE SUPPORTS. PROVIDE APPROVED PLYWOOD EDGE CLIPS CENTERED BETWEEN JOISTS/TRUSSES AT UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR SHEATHING EDGES SHALL HAVE APPROVED T&G JOINTS OR SHALL BE SUPPORTED WITH SOLID BLOCKING. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF FLOOR AND ROOF SHEATHING. TOENAIL BLOCKING TO SUPPORTS WITH 10d AT 12"oc, UNO. C. ELECTRICAL, MECHANICAL, PLUMBING, AND DRAINAGE SYSTEMS SHALL BE DESIGNED30. TO ACCOMMODATE THE DIFFERENTIAL SHRINKAGE OR MOVEMENT OF THE WOOD STRUCTURE (3/8” PER FLOOR). TRUSSES SHALL BEAR AT EXTERIOR WALLS ONLY UNLESS SPECIFICALLY NOTED ON PLANS. NOTCHES AND HOLES IN WOOD FRAMING: SAWN LUMBER JOISTS AND RAFTERS: NOTCHES AT THE ENDS OF JOISTS SHALL NOT EXCEED 1/4 THE JOIST DEPTH. NOTCHES IN THE TOP OR BOTTOM OF JOISTS SHALL NOT EXCEED 1/6 THE JOIST DEPTH, BE LONGER THAN 1/3 THE JOIST DEPTH, OR BE LOCATED IN THE MIDDLE 1/3 OF THE SPAN. HOLES SHALL NOT BE WITHIN 2" OF THE TOP OR BOTTOM OF THE JOIST AND THE DIAMETER SHALL NOT EXCEED 1/3 THE JOIST DEPTH. SPACING BETWEEN HOLES SHALL BE A MINIMUM OF (2)TIMES THE DIAMETER OF THE LARGEST HOLE OR 2" AND SHALL BE LOCATED A MINIMUM OF 2" FROM ANY NOTCH. EXTERIOR AND BEARING WALLS: WOOD STUDS ARE PERMITTED TO BE NOTCHED TO A DEPTH NOT EXCEEDING 1/4 OF ITS WIDTH. A HOLE NOT GREATER IN DIAMETER THAN 40% OF THE STUD WIDTH IS PERMITTED IN WOOD STUDS. HOLES SHALL NOT BE WITHIN 5/8" TO THE EDGE OF THE STUD. OR 2" AND SHALL NOT BE LOCATED AT THE SAME SECTION AS A NOTCH. CUTS, NOTCHES, AND HOLES IN MANUFACTURED LUMBER, PREFABRICATED PLYWOOD WEB JOISTS, AND PREFABRICATED TRUSSES ARE PROHIBITED EXCEPT WHERE NOTED ON STRUCTURAL PLANS OR PERMITTED BY MANUFACTURER'S RECOMMENDATIONS. 29. A. B. C. SPACING BETWEEN HOLES SHALL BE A MINIMUM OF (2)TIMES THE DIAMETER OF THE LARGEST HOLE PLYWOOD WEB JOIST PROVIDED. PROVIDE FOR ALL TEMPORARY AND PERMANENT TJI BRACING PER ESR-1153, TJI-4000 INSTALLATION GUIDE AND TJI-9001 INSTALLATION GUIDE. TRUSS BRACING AND BRIDGING PER IRC SECTION R802.10.3 AND THE TRUSS PLATE INSTITUTE'S BUILDING COMPONENT SAFETY INFORMATION. MANUFACTURER'S INSTALLATION INSTRUCTIONS SHALL BE AVAILABLE ON THE JOB SITE AT THE TIME OF INSPECTION PER IRC SECTION 106.1.2 PRESSURE TREATED WOOD (INCLUDES PRESERVATIVE AND FIRE TREATED) SHALL BE TREATED PER AWPA STANDARDS U1 AND M4. PRESSURE TREATED WOOD FOR ABOVE GROUND USE SHALL BE TREATED TO RETENTION OF 0.25 PCF. WOOD IN CONTINUOUS CONTACT WITH FRESH WATER OR SOIL SHALL BE TREATED TO A RETENTION OF 0.40 PCF. SODIUM BORATE (SBX) TREATED WOOD SHALL NOT BE USED WHERE EXPOSED TO WEATHER. FASTENERS AND TIMBER CONNECTORS WITHOUT AMMONIA IN DIRECT CONTACT WITH ACQ-A TO A RETENTION LEVEL OF 0.40 PCF), CBA-A (UP TO A RETENTION LEVEL OF 0.41 PCF), CA-B (UP TO A RETENTION LEVEL OF 0.21 PCF), SHALL BE G185 OR A185 HOT DIPPED OR CONTINUOUS HOT- GALVANIZED PER ASTM A653. FASTENERS AND TIMBER CONNECTORS WITH AMMONIA IN DIRECT CONTACT WITH ACQ-A (OVER A RETENTION LEVEL OF 0.40 PCF), CBA-A (OVER A RETENTION LEVEL OF 0.41 PCF), CA-B (OVER A RETENTION LEVEL OF 0.21 PCF), OR WITH ACZA TREATED WOOD SHALL BE TYPE 304 OR 316 STAINLESS STEEL. MANUFACTURER'S INSTALLATION INSTRUCTIONS SHALL BE AVAILABLE ON THE JOB SITE AT THE TIME OF INSPECTION PER IRC SECTION 106.1.2 S1.0 SCALE - NTS NOTES GENERAL STRUCTURALCCOPYRIGHT 2018 MALSAM TSANG ENGINEERING CORPORATION - ALL RIGHTS RESERVEDPlotted by: johntPlotted Date: Sep 25, 2019 - 4:13pmSEATTLE III - 51-40-01.02 N PLANALU - 47 122 S JACKSON ST - SUITE 210 MALSAMTSANGSTRUCTURALENGINEERINGSEATTLE, WA 98104 - 206.789.6038 PROJECT MANAGER DRAWN DESCRIPTION PERMIT SET 9.16.19 DATE PROJECT NO 0135.2018.08.0005 TMH ENGINEER RAF ARCH PERMIT CORRECTIONS 9.25.191 REV MAINVUE HOMES 425.646.4022 RUSS FOISY 206.623.2799 RUSSF@MALSAM-TSANG.COM A 43968 TC.IVN SA N GEFO NII E SS NOA L GNE EE O RPRTASET RESIGT DE HSFWA IN GTONR 12/S3.1 3/S3.1 HL210 2'-0"6'-21 4" LEGEND TYPICAL OPEN DECK FRAMING PER PLAN NOTE 6, UNO TYPICAL HEADERS PER PLAN NOTE 8, UNO TYPICAL FLOOR FRAMING PER PLAN NOTE 4, UNO START FRAMING LAYOUT HERE ALL BEAM, POST AND HOLDOWN LOCATION DIMENSIONS ARE TO CENTERLINE, UNO CRAWLSPACE SLAB ON GRADE PER PLAN NOTE 2 4/S3.1 8/S3.1 DD C STAD10RJ STAD10RJSW4SW44/S3.1 7/S3.1 7/S3.1 SW2 STAD14RJSTAD14RJSTAD14RJSTAD8RJSTAD8RJSTAD14RJ STAD14RJ STAD14RJ STAD14RJ MSTA24-TZ RIM TO RIM 4/S3.1 SW2SW2PHD2A PHD2A 2'-0"PHD2A PHD2A 12'-0"2'-0"7'-0"7'-0"7'-0"6'-6"6'-6"4'-6" A TYP, UNO 4x8 TYP, UNOPT 4x4 TYP, UNO 6'-71 4"10'-0"2'-0"5'-0"5'-0"5'-4"4'-3"1'-0" 5'-4"8'-2"PT 6x6C 4x8 #101 MPAIJOIST JOISTDBLDBL#102DBLDBL2/S3.1 4'-3"(2)4x8 POSTS BETWEEN MUDSILL AND MAIN FLOOR SHEATHING C SOLID VERTICAL GRAIN BLKG FOR WIDTH OF POST UP TO SHEATHING 7'-6"2'-0"5'-6"5'-6"3'-6"PT 6x8 - EXTEND UP TO BOTTOM OF SHEATHING FULL-DEPTH BLKG DSW2STAD14RJC DOUBLE BELOW EACH END OF FIREBOX FULL DEPTH BLKG AT FB LOCATION 18"Ø x 12" CONC PAD (3)PLACES PT 4x4 POST w/ ST1-TZ POST TO FTG (3)PLACES PT 2x10 LEDGER TO RIM w/ (2)10d AT 16"oc PT 2x10 LEDGER w/ (3)LEDGERLOK LL358 SCREWS AT 16"oc JUS28-TZ STAD14RJ MSTA24-TZ RIM TO RIMFULL DEPTH BLKG AT FB LOCATION INSTALL PRIOR TO LEDGER MSH422-TZ TO RIM (3)LEDGERLOK LL358 SCREWS AS SHOWN, (9)TOTAL2'-4"PT 4x8TYP1'-0" 10/S3.1 HD10-3IFTZ DOUBLE BELOW EACH END OF FIREBOX SW2 4'-0"4'-0"JUS28-2TZ JUS28-2TZ PAU66-TZ HD10-3IFTZ 3'-5" 10'-41 4"3"3'-412"3'-412"3"12'-712"10"(2) (2)(2) (2)12'-712"10"14'-0" 10'-31 2" 4'-21 2"3" 15'-81 2" 7'-0"14'-21 2" 2'-0"1'-9"SW47'-1012"PT 4x8 TYP, UNO STAD10RJ 2'-6" BATH OPT 4/S3.1 3'-712"BSTAD14RJ 4'-234"9/S3.1 SW4(2)TDL5 21'-8" STAD10 (2)TDL5 4'-1"PLAN NOTESPLAN NOTES AND FOUNDATION PLAN MAIN FLOOR WALLS SHOWN DASHED STRUCTURAL WALL BELOW STRUCTURAL WALL ABOVE HEADER/BEAM BELOW FRAMING - TYP SPAN AND EXTENTS PLUMBING PENETRATION ABOVE CONCRETE WALL BELOW NUMBER OF BUILT UP STUDS(x) FOOTING SCHEDULE MARK 1'-6" SQ x 8" DP SIZE 2'-0" SQ x 8" DP 2'-6" SQ x 10" DP 3'-0" SQ x 12" DP REINFORCING - - (3)#4 EW BOT (4)#4 EW BOT A B C D 3'-6" SQ x 12" DP (5)#4 EW BOTE MAIN FLOOR FRAMING RAISED CONCRETE STEMWALL 9-1/4" TYPICAL FLOOR FRAMING CONSISTS OF 3/4" T&G APA RATED SHEATHING (SPAN RATING 48/24) GLUE AND NAIL FLOOR SHEATHING w/ 8d AT 6"oc AT FRAMED PANEL EDGES AND AT 12"oc IN TYPICAL OPEN DECK FRAMING CONSISTS OF DECKING PER ARCHITECTURAL DRAWINGS OVER "SW_" INDICATES SHEARWALL BELOW FRAMING SHOWN. REFER TO SHEARWALL SCHEDULE ON ALL HEADERS SHALL BE 4x8, UNO. PROVIDE PT 4x4 POSTS, UNO. REFER TO DETAIL 2/S3.1 FOR REFER TO GENERAL STRUCTURAL NOTES SHEET S1.0 FOR ADDITIONAL REQUIREMENTS. OVER 2x10's AT 19.2"oc, UNO. PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND OVER MORE THAN HALF THE JOIST LENGTH. 4/S4.0 FOR ADDITIONAL INFORMATION. ALL EXTERIOR WALLS ARE SW6, UNO. PT 2x10's AT 16"oc, UNO. ADDITIONAL REQUIREMENTS. BOTTOM OF ALL FOOTINGS SHALL BE 18" MINIMUM BELOW LOWEST ADJACENT GRADE, UNO. SLAB ON GRADE SHALL BE 4" MINIMUM THICKNESS OVER 4" MIN FREE DRAINING REFER TO SHEET S3.0 FOR TYPICAL FOUNDATION AND CONCRETE DETAILS. GRAVEL OVER FIRM NATIVE SOILS OR STRUCTURAL FILL PER SOILS ENGINEER. 1. 2. 3. 4. 5. 6. 7. 8. 11. THE FIELD, UNO. STAD HOLDOWNS ARE DIMENSIONED TO THE CENTERLINE OF STRAP. PHD HOLDOWNS ARE9. DIMENSIONED TO THE CENTERLINE OF ANCHOR BOLT. DIMENSIONS ARE BASED OFF OF DRAWINGS PROVIDED BY THE ARCHITECT AND SHALL BE VERIFIED. DO NOT SCALE DRAWINGS. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS.12. PLUMBING DROPS AND CRAWLSPACE ACCESS LOCATION ARE PROVIDED BY ARCHITECT AND SHALL BE VERIFIED. 10. RAISED CONCRETE STEMWALL PER 11/S3.1 WHERE SHOWN 5/8"Ø AB SCHEDULE MARK 48"oc SPACING 42"oc 36"oc 24"oc 18"oc SW6 SW4 SW3 SW2 SW3-2 12"ocSW2-2 1 ALL EXTERIOR SHEARWALLS ARE SW6, UNO. FIREBOXFB SW2 STAD8RJSTAD8RJ14'-7" 19'-4"PHD8PHD8SW4 S2.1 FOUNDATION PLAN SCALE - 1/4" = 1'-0" FRAMING AND MAIN FLOORCCOPYRIGHT 2018 MALSAM TSANG ENGINEERING CORPORATION - ALL RIGHTS RESERVEDPlotted by: johntPlotted Date: Sep 25, 2019 - 4:14pmSEATTLE III - 51-40-01.02 N PLANALU - 47 122 S JACKSON ST - SUITE 210 MALSAMTSANGSTRUCTURALENGINEERINGSEATTLE, WA 98104 - 206.789.6038 PROJECT MANAGER DRAWN DESCRIPTION PERMIT SET 9.16.19 DATE PROJECT NO 0135.2018.08.0005 TMH ENGINEER RAF ARCH PERMIT CORRECTIONS 9.25.191 REV MAINVUE HOMES 425.646.4022 RUSS FOISY 206.623.2799 RUSSF@MALSAM-TSANG.COM A 43968 TC.IVN SA N GEFO NII E SS NOA L GNE EE O RPRTASET RESIGT DE HSFWA IN GTONR1 1 UPPER FLOOR FRAMING PLAN UPPER FLOOR WALLS SHOWN DASHED MAIN FLOOR WALLS SHOWN SOLID PLAN NOTESPLAN NOTES LEGEND STRUCTURAL WALL BELOW STRUCTURAL WALL ABOVE HEADER/BEAM BELOW FRAMING - TYP SPAN AND EXTENTS PLUMBING PENETRATION ABOVE NUMBER OF BUILT UP STUDS(x) BLOCK DIAPHRAGM - PROVIDE FLAT 2x4 BLKG w/ 8d AT 4"oc AT ALL PANEL EDGES AND 8d AT 12"oc IN THE FIELD KING STUDKS TRIMMER STUDTS TYPICAL FLOOR FRAMING CONSISTS OF 3/4" T&G APA RATED SHEATHING (SPAN RATING 48/24) GLUE AND NAIL FLOOR SHEATHING w/ 8d AT 6"oc AT FRAMED PANEL EDGES AND OVER SHEAR- "SW_" INDICATES SHEARWALL BELOW FRAMING SHOWN. REFER TO SHEARWALL SCHEDULE ON WHERE POSTS OCCUR, PROVIDE SOLID VERTICAL GRAIN BLOCKING THRU FLOOR TO MATCHING REFER TO SHEET S4.0 FOR TYPICAL WOOD FRAMING DETAILS. REFER TO GENERAL STRUCTURAL NOTES SHEET S1.0 FOR ADDITIONAL REQUIREMENTS. DO NOT SCALE DRAWINGS. REFER TO ARCH DRAWINGS FOR ALL DIMENSIONS. OVER 11-7/8" TJI 110's AT 16"oc, UNO. PROVIDE DBL JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND OVER MORE THAN HALF THE JOIST LENGTH. WALLS AND AT 12"oc IN FIELD, UNO. 4/S4.0 FOR ADDITIONAL INFORMATION. ALL EXTERIOR WALLS ARE SW6, UNO. SUPPORTS BELOW, UNO. PROVIDE (2)BEARING (TRIMMER) STUDS AT EACH END OF ALL HEADERS, BEAMS, AND GIRDER TRUSSES OVER 6'-0" IN LENGTH, UNO. NAIL ROOF SHEATHING w/ 8d AT 6"oc AT FRAMED PANEL EDGES AND OVER SHEARWALLS, AND AT 12"oc IN THE FIELD, UNO. TYPICAL WALL FRAMING CONSISTS OF 2x6's AT 16"oc AT EXTERIOR WALLS AND 2x4's or 2x6's AT 16"oc AT INTERIOR WALLS PER ARCH DRAWINGS, UNO. 1. 2. 5. 8. 11. 12. 13. 7. 4. 9. ALL REQUIRED HEADERS ARE SHOWN ON PLAN AND SHALL BE (2)2x8, UNO. REFER TO DETAIL 8/S4.0 FOR ADDITIONAL REQUIREMENTS. 6. TYPICAL ROOF FRAMING CONSISTS OF 7/16" or 1/2" APA RATED SHEATHING (SPAN RATING 32/16) OVER PRE-MANUFACTURED TRUSSES AT 24"oc, UNO. PROVIDE TIMBERLOK TLOK06 SCREWS EACH END OF ALL TRUSSES, AND EACH PLY OF ALL MULTIPLE TRUSSES, UNO. REFER TO ARCH DRAWINGS 3. FOR TRUSS PROFILE. TRUSSES SHALL BEAR AT EXTERIOR WALLS ONLY, UNO. ALL OVERFRAMING SHALL BE PER TRUSS MANUFACTURER. GABLE END TRUSSES SHALL BE DESIGNED TO SPAN OPENINGS. PLUMBING DROPS AND RECESSED LIGHTING LOCATIONS PROVIDED BY ARCHITECT AND DIMENSIONS SHALL BE VERIFIED. 10. RECESSED LIGHTING FLUSH BEAM SCHEDULE B1 MARK SIZE HANGER B2 B3 B4 BRG STUDS LSL 1-3/4 x 11-7/8 GL 3-1/2 x 11-7/8 GL 5-1/2 x 11-7/8 HD17112 THDH610 HD410 THDH7212 2 2 3 4 1 ALL GLULAM BEAMS ARE 24F-V4, UNO 2 2 PROVIDE INVERTED FLANGE (IF) HANGERS WHERE REQUIRED, UNO 1 DRAG STRUT - NAIL THRU SHEATHING w/ 8d AT 4"ocDS INTO ENTIRE LENGTH OF MEMBER PSL 7 x 11-7/8 2 START FRAMING LAYOUT HERE TYPICAL FLOOR FRAMING PER PLAN NOTE 1, UNO TYPICAL ROOF FRAMING PER PLAN NOTE 3, UNO ALL EXTERIOR WALLS SW6 PER PLAN NOTE 5, UNO TYPICAL WALL FRAMING PER PLAN NOTE 9, UNO ALL REQUIRED HEADERS ARE SHOWN ON PLAN PER PLAN NOTE 6 PT 6x6 EPCM66 RS16 x 2'-6" BEAM TO RIM (3)(2)(2)(5)GL 5-1/2 x 10-1/2 SINGLE TOP PLATE ABOVE HEADER B3 #203MPAI BEAM TO BEAM SW2SW2(3)SW2 8/S4.1 4/S4.1 SW2B2#202(2)2x8#201(2)2x8 #206 (2)2x8 #207 BALLOON FRAME WALL w/ (2)2x6 STUDS AT 16"oc DOUBLE STUDS NOT REQD ABOVE OR BELOW OPENINGS GL 5-1/2 x 10-1/2 SINGLE TOP PLATE ABOVE HEADER(2)(3)(3)GL 3-1/2 x10-1/2#217(2) 8/S4.2 8/S4.1 PSL 3-1/2 x 11-7/8 #205 PSL 5-1/4 x 11-7/8 OVERHANG BEAM 1" FROM INSIDE FACE OF WALL SISTER BEAMS TOGETHER w/ TIMBERLOK TLOK08 AT 18"oc STAGGERED 6'-71 2"8'-11 2"1'-6" 41 2"2'-41 2" 21 2"4'-01 2"4'-21 2" (3)(2)(2)RS16 x 2'-6" BEAM TO RIM (2)2x8 #209 GL 5-1/2 x 10-1/2 (2) (4)B2#210B1 DS(2)RS16(2)RS164x6RS16 THDH410 RS16 B2#212(2)RS16(2)RS16(4)5/S4.1 9/S4.2 B3 #211 VERT HTW20 BEAM TO KS (4)(5)RS16 x 3'-0" PLATE TO PLATE 7'-0"B3#213#216GL 6-3/4 x 16-1/2#215GL 6-3/4 x 16-1/2HDQ612IF 9/S4.2 12/S4.1 BEAM TO POST VERT HTW20 7'-10" BATH OPT (2)2x6 AT OPT DOOR (5)RS16 x 3'-0" PLATE TO PLATE 7/S4.1CONT GL 5-1/2 x 18 #214 BOT FLUSH (2)MPAI BEAM TO BEAM (2)MPAI BEAM TO BEAM 8/S4.2 10/S4.1 1'-91 2"4'-111 2" B1 6'-0"HM(2)MPAI BEAM TO PLATE RS16 x 3'-0" DS TO DS (3)(3)SW4B1 DS3/S4.1 B1 (2) (2) 4/S4.1 2'-21 2"11-7/8" TJI 210 AT 16"oc11-7/8" TJI 210 AT 16"oc6/S4.1 #204 (3) BRG WALL #208SW4ALIGN JOIST OVER SHEARWALLTWO STUDS MINIMUM OR POST PER PLAN ARE REQUIRED AT EACH END OF ALL SHEARWALLS AND ALL END ALL EXTERIOR WALLS SHALL BE SW6, UNLESS NOTED OTHERWISE. MP4F's INSTALLED OVER SHEATHING WITH 8d (0.131"Ø x 2-1/2") NAILS MAY BE SUBSTITUTED FOR MPA1's AT 3x STUDS OR DBL STUDS NAILED TOGETHER w/ 10d NAILING ARE REQD AT ABUTTING PANEL EDGES WHERE EMBED ANCHOR BOLTS AT LEAST 7". ALL BOLTS SHALL HAVE 3" x 3" x 0.229" PLATE WASHERS. THE PLATE BLOCK PANEL EDGES WITH 2x4 LAID FLAT AND NAIL PANELS TO INTERMEDIATE SUPPORTS WITH 8d AT 12"oc. 8d NAILS SHALL BE 0.131"Ø x 2-1/2", 10d NAILS SHALL BE 0.131"Ø x 3", AND 12d NAILS SHALL BE 0.131"Ø x 3-1/4". SHEARWALL SCHEDULE PANEL EDGE NAIL SPACING IS 3"oc OR LESS. REFER TO DETAIL A. WHERE 3x STUDS ARE USED, STAGGER NAILS STUDS SHALL RECEIVE PANEL EDGE NAILING. NAILS SHALL NOT BE SPACED LESS THAN 3/8" FROM EDGES OF SHEATHING. SHEATHING NAILS SHALL BE DRIVEN SO THEIR HEADS ARE FLUSH WITH SHEATHING (NOT COUNTERSUNK). WASHER SHALL EXTEND TO WITHIN 1/2" OF THE EDGE OF THE BOTTOM PLATE ON THE SIDE WITH SHEATHING. CONTRACTORS OPTION. MARK SHEATHING PANEL EDGE NAILING TOP PLATE CONNECTION I-JOIST RIM/BEAM SW6 SW4 SW3 1/2" PLY or 7/16" OSB 8d AT 6"oc 8d AT 4"oc 8d AT 3"oc 8d AT 2"oc 10d AT 6"oc 10d AT 4"oc (2)ROWS 10d AT 4"oc MPA1 AT 30"oc MPA1 AT 18"oc MPA1 AT 16"oc MPA1 AT 12"oc (2)ROWS 10d AT 6"oc SW2 1/2" PLY or 7/16" OSB 1/2" PLY or 7/16" OSB 1/2" PLY or 7/16" OSB AT WOOD AT CONCRETE BASE PLATE CONNECTION 12d AT 6"oc 12d AT 4"oc (2)ROWS 12d AT 6"oc 5/8"Ø AB AT 48"oc 5/8"Ø AB AT 42"oc 5/8"Ø AB AT 36"oc (2)ROWS 12d AT 4"oc 5/8"Ø AB AT 24"oc DETAIL A EDGE NAILING OVER EA STUD 10d NAILING PLAN VIEW AT ABUTTING PANEL EDGES PER FOOTNOTE 4 PER SCHEDULE SHEATHING EDGE AT ADJOINING PANEL EDGES. 1 2 3 5 6 7 8 4 4 1 2 3 4 5 6 7 8 12'-0" 11/S4.1 4x6SW2 SW2SW4ALIGN CONT DS JOIST OVER SHEARWALL(2) (2)(3)(2)(3)RS16 x 3'-0" PLATE TO PLATE (4)11-7/8" TJI 230 AT 16"ocPT 4x4 (2)PBES44 PT 4x4 (2)PBES44 4x6 4x8 HUS481FHUS48IFGL 3-1/2 x 12#21812/S4.2 4x6 HUS481F4x8SW4(2) (2)(2)2x10#219(2)(2)2x8 #220 (2)RS16(2)RS16SW4 4x6(2)RS16(2)RS16S2.2 SCALE - 1/4" = 1'-0" FRAMING PLAN UPPER FLOORCCOPYRIGHT 2018 MALSAM TSANG ENGINEERING CORPORATION - ALL RIGHTS RESERVEDPlotted by: johntPlotted Date: Sep 25, 2019 - 4:14pmSEATTLE III - 51-40-01.02 N PLANALU - 47 122 S JACKSON ST - SUITE 210 MALSAMTSANGSTRUCTURALENGINEERINGSEATTLE, WA 98104 - 206.789.6038 PROJECT MANAGER DRAWN DESCRIPTION PERMIT SET 9.16.19 DATE PROJECT NO 0135.2018.08.0005 TMH ENGINEER RAF ARCH PERMIT CORRECTIONS 9.25.191 REV MAINVUE HOMES 425.646.4022 RUSS FOISY 206.623.2799 RUSSF@MALSAM-TSANG.COM A 43968 TC.IVN SA N GEFO NII E SS NOA L GNE EE O RPRTASET RESIGT DE HSFWA IN GTONR1 1 ROOF FRAMING PLAN UPPER FLOOR WALLS SHOWN SOLID PLAN NOTESPLAN NOTES LEGEND STRUCTURAL WALL BELOW HEADER/BEAM BELOW FRAMING - TYP SPAN AND EXTENTS NUMBER OF BUILT UP STUDS(x) GIRDER TRUSSGT FULL HEIGHT KING STUD w/ MPAI TOP AND BOTTOMKS TYPICAL ROOF FRAMING CONSISTS OF 7/16" or 1/2" APA RATED SHEATHING (SPAN RATING 32/16) NAIL ROOF SHEATHING w/ 8d AT 6" oc AT FRAMED PANEL EDGES AND OVER SHEARWALLS, AND "SW_" INDICATES SHEARWALL BELOW FRAMING SHOWN. REFER TO SHEARWALL SCHEDULE ON ALL HEADERS SHALL BE (2)2x6, UNO. REFER TO DETAIL 8/S4.0 FOR ADDITIONAL REQUIREMENTS. PROVIDE (2)BEARING (TRIMMER) STUDS AT EACH END OF ALL HEADERS, BEAMS, AND GIRDER WHERE POSTS OCCUR, PROVIDE SOLID VERTICAL GRAIN BLOCKING THRU FLOOR TO MATCHING OVER PRE-MANUFACTURED TRUSSES AT 24"oc, UNO. PROVIDE TIMBERLOK TLOK06 SCREWS EACH AT 12"oc IN FIELD, UNO. 4/S4.0 FOR ADDITIONAL INFORMATION. ALL EXTERIOR WALLS ARE SW6, UNO. TRUSSES OVER 6'-0" IN LENGTH, UNO. SUPPORTS BELOW, UNO. END OF ALL TRUSSES, AND EACH PLY OF ALL MULTIPLE TRUSSES, UNO. REFER TO ARCH DRAWINGS TYPICAL WALL FRAMING CONSISTS OF 2x6's AT 16"oc AT EXTERIOR WALLS AND 2x4's or 2x6's AT 16"oc AT INTERIOR WALLS PER ARCH DRAWINGS, UNO. 1. 2. 3. 4. 5. 6. 7. FOR TRUSS PROFILE. TRUSSES SHALL BEAR AT EXTERIOR WALLS ONLY, UNO. ALL OVERFRAMING REFER TO SHEET S4.0 FOR TYPICAL WOOD FRAMING DETAILS. REFER TO GENERAL STRUCTURAL NOTES SHEET S1.0 FOR ADDITIONAL REQUIREMENTS. DO NOT SCALE DRAWINGS. REFER TO ARCH DRAWINGS FOR ALL DIMENSIONS. 9. 10. 11. RECESSED LIGHTING AND ATTIC ACCESS LOCATIONS ARE PROVIDED BY ARCHITECT AND DIMENSIONS SHALL BE VERIFIED. 8. SHALL BE PER TRUSS MANUFACTURER. GABLE END TRUSSES SHALL BE DESIGNED TO SPAN OPENINGS. RECESSED LIGHTING TRIMMER STUDTS HIP MASTERHM MODIFIED TRUSSES - TRUSS MANUFACTURER TO DESIGN FOR MINIMUM 20PSF LOAD AT BOTTOM CHORD TYPICAL ROOF FRAMING PER PLAN NOTE 1, UNO ALL EXTERIOR WALLS SW6 PER PLAN NOTE 3, UNO TYPICAL WALL FRAMING PER PLAN NOTE 7, UNO TYPICAL HEADERS PER PLAN NOTE 4, UNO 4x10 #301 (2)2x6 #302 SW4 SW4GL 3-1/2 x 10-1/2 #303 (2)(2)(2) (2)(2)2x8#307(2)2x8#306(2) (2) (2) (2) (2)2x8 #305 GL 3-1/2 x 10-1/2 #304 8/S4.2 8/S4.2 (2)(2)(2)SW6SW6SW63/S4.2 3/S4.2 HM8'-0"4'-0"8'-0"GTGTDT1.1DT1.24'-134"6'-634"BALLOON FRAME WALL w/ (2)2x6 STUDS AT 16"oc DOUBLE STUDS NOT REQD ABOVE OR BELOW OPENINGS 29'-11 4"(2)GT GT GT HMGTRT7A TRUSS TO PLATE EACH END RT7A TRUSS TO PLATE EACH END 6'-0" 6'-0" PROVIDE FOR ALL TEMPORARY AND PERMANENT TRUSS BRACING AND BRIDGING PER12. IRC SECTION R802.10.3 AND THE TRUSS PLATE INSTITUTE'S BUILDING COMPONENT SAFETY INFORMATION. DRAG TRUSS SCHEDULE DT1.1 MARK 2.8 KIPS LOAD TRANSFER DT1.2 2.2 KIPS 1 TRUSS MFR TO DESIGN TRUSS TO TRANSFER 2 NAIL THRU SHEATHING w/ 8d AT 4"oc INTO 1 2 LISTED LOAD FROM TOP TO BOT CHORD ENTIRE LENGTH OF MEMBER TWO STUDS MINIMUM OR POST PER PLAN ARE REQUIRED AT EACH END OF ALL SHEARWALLS AND ALL END ALL EXTERIOR WALLS SHALL BE SW6, UNLESS NOTED OTHERWISE. MP4F's INSTALLED OVER SHEATHING WITH 8d (0.131"Ø x 2-1/2") NAILS MAY BE SUBSTITUTED FOR MPA1's AT 3x STUDS OR DBL STUDS NAILED TOGETHER w/ 10d NAILING ARE REQD AT ABUTTING PANEL EDGES WHERE EMBED ANCHOR BOLTS AT LEAST 7". ALL BOLTS SHALL HAVE 3" x 3" x 0.229" PLATE WASHERS. THE PLATE BLOCK PANEL EDGES WITH 2x4 LAID FLAT AND NAIL PANELS TO INTERMEDIATE SUPPORTS WITH 8d AT 12"oc. 8d NAILS SHALL BE 0.131"Ø x 2-1/2", 10d NAILS SHALL BE 0.131"Ø x 3", AND 12d NAILS SHALL BE 0.131"Ø x 3-1/4". SHEARWALL SCHEDULE PANEL EDGE NAIL SPACING IS 3"oc OR LESS. REFER TO DETAIL A. WHERE 3x STUDS ARE USED, STAGGER NAILS STUDS SHALL RECEIVE PANEL EDGE NAILING. NAILS SHALL NOT BE SPACED LESS THAN 3/8" FROM EDGES OF SHEATHING. SHEATHING NAILS SHALL BE DRIVEN SO THEIR HEADS ARE FLUSH WITH SHEATHING (NOT COUNTERSUNK). WASHER SHALL EXTEND TO WITHIN 1/2" OF THE EDGE OF THE BOTTOM PLATE ON THE SIDE WITH SHEATHING. CONTRACTORS OPTION. MARK SHEATHING PANEL EDGE NAILING TOP PLATE CONNECTION I-JOIST RIM/BEAM SW6 SW4 SW3 1/2" PLY or 7/16" OSB 8d AT 6"oc 8d AT 4"oc 8d AT 3"oc 8d AT 2"oc 10d AT 6"oc 10d AT 4"oc (2)ROWS 10d AT 4"oc MPA1 AT 30"oc MPA1 AT 18"oc MPA1 AT 16"oc MPA1 AT 12"oc (2)ROWS 10d AT 6"oc SW2 1/2" PLY or 7/16" OSB 1/2" PLY or 7/16" OSB 1/2" PLY or 7/16" OSB AT WOOD AT CONCRETE BASE PLATE CONNECTION 12d AT 6"oc 12d AT 4"oc (2)ROWS 12d AT 6"oc 5/8"Ø AB AT 48"oc 5/8"Ø AB AT 42"oc 5/8"Ø AB AT 36"oc (2)ROWS 12d AT 4"oc 5/8"Ø AB AT 24"oc DETAIL A EDGE NAILING OVER EA STUD 10d NAILING PLAN VIEW AT ABUTTING PANEL EDGES PER FOOTNOTE 4 PER SCHEDULE SHEATHING EDGE AT ADJOINING PANEL EDGES. 1 2 3 5 6 7 8 4 4 1 2 3 4 5 6 7 8 3 DRAG TRUSSES ARE NOT REQUIRED DIRECTLY ABOVE SHEARWALL, UNO ABOVE HEADER SINGLE TOP PLATE (2)(2)SW4SW4 GL 3-1/2 x 10-1/2 #308 (2)(2)(2)(2)S2.3 SCALE - 1/4" = 1'-0" FRAMING PLAN ROOF CCOPYRIGHT 2018 MALSAM TSANG ENGINEERING CORPORATION - ALL RIGHTS RESERVEDPlotted by: johntPlotted Date: Sep 25, 2019 - 4:14pmSEATTLE III - 51-40-01.02 N PLANALU - 47 122 S JACKSON ST - SUITE 210 MALSAMTSANGSTRUCTURALENGINEERINGSEATTLE, WA 98104 - 206.789.6038 PROJECT MANAGER DRAWN DESCRIPTION PERMIT SET 9.16.19 DATE PROJECT NO 0135.2018.08.0005 TMH ENGINEER RAF ARCH PERMIT CORRECTIONS 9.25.191 REV MAINVUE HOMES 425.646.4022 RUSS FOISY 206.623.2799 RUSSF@MALSAM-TSANG.COM A 43968 TC.IVN SA N GEFO NII E SS NOA L GNE EE O RPRTASET RESIGT DE HSFWA IN GTONR1 1 432 8 12 765 109 11 SINGLE CURTAIN CROSS WALL HORIZ REINF MATCH CROSS WALL CORNER BARS TO CORNER BARS TO MATCH HORIZ REINF TYP CORNER BARS:2424ADDITIONAL VERT BARS TYP CORNER BARS AT CONCRETE WALLS AND FTGS TYPICAL STEPPED FOOTINGD3'-0" MAX3'-0" MIND DDNORMAL FOOTING REINFORCING ADD BARS TO MATCH NORMAL REINFORCING LINE OF EXCAVATION REINFORCING NORMAL FOOTING CONCRETE WALL ADD (2)#4 DIAGONAL IN WALL 2'-0" MIN EXCAVATION NOT ALLOWED BELOW THIS LINE 1 1 PIPE AND TRENCH LOCATIONS4"6"3'-0" MAX1'-6" MIN PIPE SLEEVES AS REQD3-1/2" CLR MINDO NOT PASS PIPESTHRU THIS AREAWHERE OCCURS CORNER OF FOUNDATION MIN 2 STUDS (MIN (3)STUDS WHERE CORNER OCCURS) (24)16d SINKERS HOLDOWN PER PLAN JUST PRIOR TO COVERING FRAMING CONT WHERE OCCURS PLAN MARK STAD8(RJ) HD POST INSTALL OVER SHEATHING PROVIDE PANEL EDGE NAILING OVER ALL HOLDOWN STUDS OR (2)ROWS AT POST HOLDOWN CAN BE ATTACHED TO BEARING (TRIMMER) STUDS LEAVE STRAP UN-NAILED NAIL MULTIPLE HOLDOWN STUDS w/ (2)10d AT 6"oc STAD10(RJ) STAD14(RJ) NAILS (28)16d SINKERS (38)16d SINKERS DBL STUD CORNER CONDITION EXTRA STUD AT STAD HOLDOWN SCHEDULE DBL STUD DBL STUD 16d SINKERS = 0.148"Ø x 3-1/4" MINIMUM SIZE OF POST UNO ON FRAMING PLANS 1 2 1 2 1 1/2" MIN SHEARWALL PER PLAN 3"6"3"6"8"4'-0" MINSLAB ON GRADE WHERE OCCURS #4 AT 18"oc VERT (2)#4 CONT TOPMIN 8'-0" MAX#4 AT 12"oc HORIZ ALT HOOKS 3'-0" MAX SOIL HTDIFFERENCE(2)#4 CONT BACKFILL TO BE FULLY COMPACTED 4" UP TO 6'-0" STEMWALL 6"4" UP TO 8'-0" STEMWALL FOOTING DRAIN MATERIAL PROVIDE FREE-DRAINING FLOOR FRAMING NOT SHOWN REFER TO SHEET S3.1 FOR MUDSILL AND AB REQUIREMENTS GRADE GRADE4'-0" MAX BACKFILL8"MIN8"CL STRAP RIM JOISTPT 2x SILL PLATE (2)2x TOP PLATE 2 MAX 1 HOLDOWN IS SPECIFIED SHEATHE AND NAIL PONY WALL TO MATCH HOLDOWN PER PLAN CONCRETE STEPPED FOOTING PER 8/S3.01'-6" MIN4'-0" MAXSHEARWALL ABOVE PROVIDE RS16 x 3'-0" GR A D E PROVIDE KST260 BETWEEN WALL ABOVE WHERE FDN BETWEEN PONY WALL AND HD TO BE PLACED AT FLOOR LEVEL AND PROVIDE ALL-THRD AND THRD COUPLER AS REQD 3/S3.0 1'-6" MIN8"JOIST DIRECTION AND SHEARWALL PER PLAN SHEATHING PER PLAN (4)8d EA BLOCK HD STUDS AND POSTS VERT GRAIN BLKG TO MATCH PT 2x6 PLATE w/ AB PER SHEARWALL SCHEDULE (5/8"Ø AT 48"oc ELSEWHERE) 2x RIM JOIST OR NAILING PER SHEARWALL SCHEDULE FOUNDATION PER 4/S3.1MINWHERE JOISTS ARE PARALLEL PROVIDE 2x BLKG (MIN 12"L) AT 48"oc BEAM PER PLAN KST260 BETWEEN PONY WALL AND WALL ABOVE WHEN FDN HD IS SPECIFIED SHEATHE AND NAIL PONY WALL TO MATCH SHEARWALL ABOVE HOLDOWN PER PLAN EACH JOIST OR BLOCK (3)10d TOENAILS THRU SCHEDULE MPA1 PER SHEARWALL PANEL EDGE NAILING OVER HOLDOWN STUDS TYPICAL PONY WALLSTYPICAL PONY WALLS TYPICAL DEEP FTG HD POSTAT STEMWALL AT FOOTING (2)2x4 (2)2x65/8"Ø12-13/16" 16-13/16"5/8"Ø - STB20 5/8"Ø - STB16 ALL-THREAD 5/8"Ø - STB24 WASHEREMBEDAB PHD2A PHD5A PHD4A 20-13/16" 5/8"Ø 5/8"Ø 9" 9" EMBED 9" 4x WALL 6x WALL (2)2x4 (2)2x4 PHD HOLDOWN SCHEDULE (2)2x6 (2)2x6 A307 ALL-THREAD w/ PLATE WASHER PER SCHEDULE AND DOUBLE NUT BOTTOM MINIMUM SIZE OF POST UNO ON FRAMING PLANS PLAN MARK 1-3/4"SQ x 1/2 1-3/4"SQ x 1/2 1-3/4"SQ x 1/2 ALL-THREAD PER SCHEDULE STB PER SCHEDULE PLATE WASHER PER SCHEDULE 2 1 WHERE OCCURS STUDS OR (2)ROWS AT POST w/ WS3 SCREWS FRAMING CONT PROVIDE PANEL EDGE NAILING OVER ALL HOLDOWN ATTACHED TO BEARING HOLDOWN CAN BE (TRIMMER) STUDS HOLDOWN STUDS NAIL MULTIPLE w/ (2)10d AT 6"oc PHD HOLDOWN HOLDOWN STUDS/POST PER SCHEDULE SHEARWALL PER PLAN 1 2 S3.0 SCALE - NTS DETAILS TYPICAL CONCRETECCOPYRIGHT 2018 MALSAM TSANG ENGINEERING CORPORATION - ALL RIGHTS RESERVEDPlotted by: johntPlotted Date: Sep 25, 2019 - 4:14pmSEATTLE III - 51-40-01.02 N PLANALU - 47 122 S JACKSON ST - SUITE 210 MALSAMTSANGSTRUCTURALENGINEERINGSEATTLE, WA 98104 - 206.789.6038 PROJECT MANAGER DRAWN DESCRIPTION PERMIT SET 9.16.19 DATE PROJECT NO 0135.2018.08.0005 TMH ENGINEER RAF ARCH PERMIT CORRECTIONS 9.25.191 REV MAINVUE HOMES 425.646.4022 RUSS FOISY 206.623.2799 RUSSF@MALSAM-TSANG.COM A 43968 TC.IVN SA N GEFO NII E SS NOA L GNE EE O RPRTASET RESIGT DE HSFWA IN GTONR 4321 8 12 765 109 11 3"6"3" PT 2x6 PLATE w/ AB PER SHEARWALL SCHEDULE (5/8"Ø AT 48"oc ELSEWHERE) SLAB ON GRADE PER PLAN HOLDOWN PER PLAN SLAB ON GRADE WHERE OCCURS 1'-6" MIN6"8"5'-0" MAXMINSHEARWALL PER PLAN PANEL EDGE NAILING OVER HOLDOWN STUDS 2'-0"MAX(1)#4 TOP AND BOT HORIZ AND #4 AT 48"oc VERT3'-0" MAXALT STD HOOKS 3"6"3"1'-6" MIN6"8"5'-0" MAX3'-0"(1)#4 TOP AND BOT HORIZ AND #4 AT 48"oc VERT 3'-0" MAXALT STD HOOKS JOIST DIRECTION AND SLAB ON GRADE WHERE OCCURS SHEARWALL PER PLAN PANEL EDGE NAILING OVER HOLDOWN STUDS SHEATHING PER PLAN (4)8d EA BLOCK EACH JOIST OR BLOCK (3)10d TOENAILS THRU HD STUDS AND POSTS VERT GRAIN BLKG TO MATCH PT 2x6 PLATE w/ AB PER SHEARWALL SCHEDULE (5/8"Ø AT 48"oc ELSEWHERE) WHERE JOISTS ARE PARALLEL PROVIDE 2x BLKG (MIN 12"L) AT 48"ocCONTSHEATHINGSHEARWALL ABOVE EDGE NAILING OF HOLDOWN PER PLAN NAILING PER SHEARWALL 2x RIM JOIST OR SCHEDULE BEAM PER PLAN MINMAXCL POST AND FTG PT POST PER PLAN 10"SQ PLINTH REINF w/ (4)#4 x VERT 1'-6" MIN8"5'-0" MAXMINPOST BASE PER PLAN w/ 5/8"Ø x 8" AB FOOTING PER PLAN 10"1'-0"8"JOIST DIRECTION AND SHEARWALL PER PLAN PANEL EDGE NAILING OVER HOLDOWN STUDS SHEATHING PER PLAN (4)8d EA BLOCK EACH JOIST OR BLOCK (3)10d TOENAILS THRU HD STUDS AND POSTS VERT GRAIN BLKG TO MATCH PT 2x6 PLATE w/ AB PER SHEARWALL SCHEDULE (5/8"Ø AT 48"oc ELSEWHERE) WHERE JOISTS ARE PARALLEL PROVIDE 2x BLKG (MIN 12"L) AT 48"oc HOLDOWN PER PLAN NAILING PER SHEARWALL JOIST, BLKG, OR SCHEDULE BEAM PER PLAN MINMPA1 PER SHEARWALL SCHEDULE AT HOLDOWN AB FOOTING 1'-2" DP x 1'-6"L SHEATHE AND NAIL PONY WALL TO MATCH WALL ABOVE PROVIDE MATCHING HOLDOWN POST (2)CONT TOP AND BOT AB PER HD SCHEDULE w/ MATCHING ALL-THREAD AND THRD COUPLER8"JOIST DIRECTION AND SHEATHING PER PLAN (3)10d TOENAILS PT POST PER PLAN w/ HEADER/BEAM PER PLAN 8d AT 6"oc INTO (3)10d TOENAILS 2x BLOCKING MINMP34 w/ POWDER ACTUATED ANCHOR 1'-6" MIN1'-0" MINOR STI-TZ 1x4 x 1'-6" EA SIDE w/ (8)10d FTG PER PLAN (2)LAYERS OF BLDG PAPER BETWEEN POST AND CONC EA BLOCK THRU EACH JOIST 3"6"3"1'-6" MIN6"8"5'-0" MAX3'-0"(1)#4 TOP AND BOT HORIZ AND #4 AT 48"oc VERT 3'-0" MAXALT STD HOOKS JOIST DIRECTION AND SLAB ON GRADE WHERE OCCURS SHEARWALL PER PLAN SHEATHING PER PLAN PT 2x6 PLATE w/ AB PER SHEARWALL SCHEDULE (5/8"Ø AT 48"oc ELSEWHERE) (2)LAYERS OF BLDG PAPER OR (1)LAYER OF 'VICOR' SNUG FIT BETWEEN JOISTS AND WALL HOLDOWN PER PLAN NAILING PER SHEARWALL SCHEDULE MINMAXTOP FLANGE HANGER HL OR SW SERIES PANEL EDGE NAILING OVER HOLDOWN STUDS 3"6"3" SLAB ON GRADE PER PLAN (2)LAYERS OF BLDG PAPER 1'-6" MIN6"8"5'-0" MAXMIN3'-0"MAX(1)#4 TOP AND BOT HORIZ AND #4 AT 48"oc VERT3'-0" MAXALT STD HOOKS POST PER PLAN WALL THICKNESS PER PLAN 14" MIN AT POST (2)TLD5 EA POST w/ 1/2"Ø x 5" EXP AB - 5" MIN EDGE DISTANCE PROVIDE PAU w/ 5/8"Ø x 8" AB WHERE NOTED ON PLAN POST PER PLAN PLAN VIEW AT CORNER MID WALL TDL5 - TYP DECK JOISTS PERPENDICULAR TO RIM2"2"PT 2x LEDGER w/ SCREWS PER PLAN DECK JOISTS PARALLEL TO RIM PT 2x LEDGER w/ (2)10d AT 16"oc PT DECK JOISTS PER PLAN 5/4" x 4" CEDAR DECKING PT DECK JOISTS PER PLAN LUS SERIES HANGER OR EQUAL 5/4" x 4" CEDAR DECKING OR EQUAL EQ EQ THIRD SCREW WHERE OCCURS S3.1 SCALE - NTS CONCRETE DETAILSCCOPYRIGHT 2018 MALSAM TSANG ENGINEERING CORPORATION - ALL RIGHTS RESERVEDPlotted by: johntPlotted Date: Sep 25, 2019 - 4:14pmSEATTLE III - 51-40-01.02 N PLANALU - 47 122 S JACKSON ST - SUITE 210 MALSAMTSANGSTRUCTURALENGINEERINGSEATTLE, WA 98104 - 206.789.6038 PROJECT MANAGER DRAWN DESCRIPTION PERMIT SET 9.16.19 DATE PROJECT NO 0135.2018.08.0005 TMH ENGINEER RAF ARCH PERMIT CORRECTIONS 9.25.191 REV MAINVUE HOMES 425.646.4022 RUSS FOISY 206.623.2799 RUSSF@MALSAM-TSANG.COM A 43968 TC.IVN SA N GEFO NII E SS NOA L GNE EE O RPRTASET RESIGT DE HSFWA IN GTONR 421 8 12 765 10 11 I-JOIST BLKG JOIST/BLOCK PANEL EDGE NAILING SHEATHING PANEL JOINT BETWEEN JOISTS BEARING WALL NON-BEARING WALL TYPICAL SHEARWALL CONSTRUCTION (2)10d EACH TOP PLATE CONNECTION PER SHEARWALL SCHEDULE I-JOISTS I-JOIST BLKG w/ PANEL EDGE NAILING 2x4 BLOCKING BETWEEN STUDS PANEL EDGE NAILING BOTTOM PLATE CONNECTION (MIN 12"L) AT 48"oc PER PLAN (4)8d INTO EA BLOCK SEE SHEARWALL SCHEDULE FOR ALL NAILING AND CONNECTIONS, NOT OTHERWISE NOTED NOTE: OF SHEARWALL BELOW PANEL EDGE NAILING 10d NAILING PER SHEARWALL 10d NAILING PER SHEARWALL PANEL EDGE NAILING PER TYPICAL SHEARWALL INTERSECTIONS SCHEDULE OF HIGHER CAPACITY SHEARWALL or 10d AT 12"oc AT SHEARWALL PER PLAN SHEARWALL SCHEDULE SCHEDULE NON-SHEARWALLS SCALE: 1-1/2" = 1'-0" SHEARWALL PER PLAN SHEARWALL PER PLAN SHEARWALL PER PLAN SHEARWALL PER PLAN 1 1 1 3 32 1 3 2 1 2 1 1 TYPICAL FLUSH AND DROPPED BEAM PER PLAN THF SERIES HANGER BEAM PER PLAN JOISTS AND SHEATHING 8d AT 6"oc PER PLAN (2)10d THRU EACH JOIST BEAM PER PLAN JOISTS AND SHEATHING 8d AT 6"oc INTO I-JOIST BLKG (3)10d EACH BLOCK TYPICAL STUDS HEADER OR BEAM PER PLAN PROVIDE (2)BEARING 'TRIMMER' (6)10d INTO HEADER MPA1 AT TOP AND BOTTOM DOUBLE TOP PLATE STUDS AT ENDS OF ALL HEADERS OR BEAMS OVER 6'-0" IN LENGTH HEADER TO BE TIGHT AGAINST EXT SHEATHING AT EXTERIOR WALLS ONLY ADDITIONAL BEARING 'TRIMMER' STUDS WHERE SPECIFIED ON PLAN OMIT AT OPENINGS < 6'-0" WHERE OPENING > 8'-0" LOCATE DIRECTLY OVER OPENING DOUBLE SILL PLATES WHERE OPENING > 8'-0" DOUBLE KING STUD WHERE OPENING > 8'-0" BOTTOM PLATE BOTTOM CHORD SPLICE 10d AT 12"oc STAGGERED ELSEWHERE TOP CHORD SPLICE AT EACH SIDE OF SPLICE (12)10d AT 4"oc STAGGERED 4'-0" MIN BETWEEN SPLICES SPLICE TO OCCUR AT C OF VERT STUD TYPICAL TYPICAL TOP PLATE SPLICE L AT SHEARWALLS NOTE: 1. NAILING AT TOP PLATE SPLICES MAY BE ELIMINATED w/ RS16 x 30" 2. WHERE VERTICAL PENETRATIONS THRU PLATE EXCEED 1" FOR A WALL OR 3" FOR A 6x WALL - PROVIDE RS16 x 30" AT TOP PLATE 3. MINIMUM EDGE DISTANCE FOR VERTICAL PENETRATIONS THRU TOP PLATE IS 1-1/4" TYPICAL RS16 HOLDOWN RS HOLDOWN PER PLAN w/ (16)8d EA END OF STRAP FULL WIDTH VERT GRAIN REFER TO PLAN FOR LOCATIONS WHERE WALL CONTINUES JOIST DIRECTION PER PLAN 2x BLKG TO MATCH HOLDOWN STUDS 1'-2" MIN1'-2" MINHEADER/BEAM PER PLAN BEARING (TRIMMER) STUD BELOW HEADER/BEAM LEAVE HOLDOWN UN-NAILED UNTIL JUST PRIOR TO COVERING SHEARWALL PER PLAN HOLDOWN CAN BE ATTACHED TO BEARING 'TRIMMER' STUD INSTALLED OVER SHEATHING NAIL MULTIPLE HOLDOWN STUDS w/ (2)10d AT 6"oc SHEATHING PER PLAN 1'-2" MINPRE-MFR TRUSSES AND (SIZE AND CONN PER ARCH) CLG SHTG WHERE OCCURS SHEATHING PER PLAN DO NOT CONNECT TO FRMG WITHIN 16" OF WALL PLATE CONNECT TO WALL PLATE w/ DC1 CLIPS AT 16"oc 1'-4" MIN 2'-0" MAXw/ (2)10d EA END 2x BLKG AT 48"oc NON-BEARING WALL PER ARCH 1'-4" MIN 2'-0" MAX NAIL MID-HEIGHT OF SLOT TR1 CLIP AT 48"oc EQ EQ EQ EQ3/4"GAP3/4"GAPPERPENDICULARPARALLEL TYPICAL NON-STRUCTURAL WALL TO ROOF TRUSSES TYPICAL HEADER SUPPORT TWO STUDS MINIMUM OR POST PER PLAN ARE REQUIRED AT EACH END OF ALL SHEARWALLS AND ALL END ALL EXTERIOR WALLS SHALL BE SW6, UNLESS NOTED OTHERWISE. MP4F's INSTALLED OVER SHEATHING WITH 8d (0.131"Ø x 2-1/2") NAILS MAY BE SUBSTITUTED FOR MPA1's AT 3x STUDS OR DBL STUDS NAILED TOGETHER w/ 10d NAILING ARE REQD AT ABUTTING PANEL EDGES WHERE EMBED ANCHOR BOLTS AT LEAST 7". ALL BOLTS SHALL HAVE 3" x 3" x 0.229" PLATE WASHERS. THE PLATE BLOCK PANEL EDGES WITH 2x4 LAID FLAT AND NAIL PANELS TO INTERMEDIATE SUPPORTS WITH 8d AT 12"oc. 8d NAILS SHALL BE 0.131"Ø x 2-1/2", 10d NAILS SHALL BE 0.131"Ø x 3", AND 12d NAILS SHALL BE 0.131"Ø x 3-1/4". SHEARWALL SCHEDULE PANEL EDGE NAIL SPACING IS 3"oc OR LESS. REFER TO DETAIL A. WHERE 3x STUDS ARE USED, STAGGER NAILS STUDS SHALL RECEIVE PANEL EDGE NAILING. NAILS SHALL NOT BE SPACED LESS THAN 3/8" FROM EDGES OF SHEATHING. SHEATHING NAILS SHALL BE DRIVEN SO THEIR HEADS ARE FLUSH WITH SHEATHING (NOT COUNTERSUNK). WASHER SHALL EXTEND TO WITHIN 1/2" OF THE EDGE OF THE BOTTOM PLATE ON THE SIDE WITH SHEATHING. CONTRACTORS OPTION. MARK SHEATHING PANEL EDGE NAILING TOP PLATE CONNECTION I-JOIST RIM/BEAM SW6 SW4 SW3 1/2" PLY or 7/16" OSB 8d AT 6"oc 8d AT 4"oc 8d AT 3"oc 8d AT 2"oc 10d AT 6"oc 10d AT 4"oc (2)ROWS 10d AT 4"oc MPA1 AT 30"oc MPA1 AT 18"oc MPA1 AT 16"oc MPA1 AT 12"oc (2)ROWS 10d AT 6"oc SW2 1/2" PLY or 7/16" OSB 1/2" PLY or 7/16" OSB 1/2" PLY or 7/16" OSB AT WOOD AT CONCRETE BASE PLATE CONNECTION 12d AT 6"oc 12d AT 4"oc (2)ROWS 12d AT 6"oc 5/8"Ø AB AT 48"oc 5/8"Ø AB AT 42"oc 5/8"Ø AB AT 36"oc (2)ROWS 12d AT 4"oc 5/8"Ø AB AT 24"oc DETAIL A EDGE NAILING OVER EA STUD 10d NAILING PLAN VIEW AT ABUTTING PANEL EDGES PER FOOTNOTE 4 PER SCHEDULE SHEATHING EDGE AT ADJOINING PANEL EDGES. 1 2 3 5 6 7 8 4 4 1 2 3 4 5 6 7 8 S4.0 SCALE - NTS FRAMING DETAILS TYPICAL WOOD CCOPYRIGHT 2018 MALSAM TSANG ENGINEERING CORPORATION - ALL RIGHTS RESERVEDPlotted by: johntPlotted Date: Sep 25, 2019 - 4:14pmSEATTLE III - 51-40-01.02 N PLANALU - 47 122 S JACKSON ST - SUITE 210 MALSAMTSANGSTRUCTURALENGINEERINGSEATTLE, WA 98104 - 206.789.6038 PROJECT MANAGER DRAWN DESCRIPTION PERMIT SET 9.16.19 DATE PROJECT NO 0135.2018.08.0005 TMH ENGINEER RAF ARCH PERMIT CORRECTIONS 9.25.191 REV MAINVUE HOMES 425.646.4022 RUSS FOISY 206.623.2799 RUSSF@MALSAM-TSANG.COM A 43968 TC.IVN SA N GEFO NII E SS NOA L GNE EE O RPRTASET RESIGT DE HSFWA IN GTONR 4321 8 12 765 109 11 (4)8d INTO EACH BLOCK JOIST DIRECTION AND SHEATHING PER PLAN HEADER/BEAM PER PLAN (MIN 12"L) AT 48"oc JOIST OR BLOCK (2)10d THRU EA PROVIDE I-JOIST BLKG WHERE JOISTS ARE PARALLEL 1-1/4" LSL RIM JOIST 12d AT 8"oc LEAVE (1)END UN-NAILED UNTIL PRIOR TO COVERING SHEARWALL PER PLAN OR BEAM PER PLAN HOLDOWN STUDS AND POSTS VERT GRAIN BLKG TO MATCH WRAP HEADER WHERE OCCURS HOLDOWN PER PLAN EDGE NAILING OF SHEARWALL ABOVE EDGE NAILING OF SHEARWALL BELOW2'-0" MINPANEL EDGE NAILING OVER ALL HOLDOWN STUDS SHEATHINGCONTSHEATHING EDGE SHEARWALL SCHEDULE NAILING PER 10d PER SHEARWALL BELOW 12d AT 8"oc 2'-0" MINPANEL EDGE NAILING OVER ALL HOLDOWN STUDS SHEATHINGCONTSHEATHING EDGE EDGE NAILING OF SHEARWALL ABOVE 1'-2" MINRS HOLDOWN PER PLAN w/ (16)8d EACH END OF STRAP INTO HOLDOWN STUDS AND BEAM BELOW (4)8d INTO EACH BLOCK BEAM PER PLAN SHEARWALL PER PLAN JOISTS AND SHEATHING PER PLAN I-JOIST BLKG (MIN12"L) AT 48"oc SHEARWALL SCHEDULE NAILING PER 12d AT 8"oc 2'-0" MINPANEL EDGE NAILING OVER ALL HOLDOWN STUDS CONTSHEATHING EDGE EDGE NAILING OF SHEARWALL ABOVE 1'-2" MINRS HOLDOWN PER PLAN w/ (16)8d EACH END OF STRAP INTO HOLDOWN STUDS AND BEAM BELOW (4)8d INTO EACH BLOCK 1-1/4" LSL RIM JOIST SHEARWALL PER PLAN HEADER/BEAM PER PLAN (MIN 12"L) AT 48"oc JOIST OR BLOCK (2)10d THRU EA PROVIDE I-JOIST BLKG WHERE JOISTS ARE PARALLEL MPA1 AT 30"oc SHEATHINGJOIST DIRECTION AND SHEATHING PER PLANSHEARWALL SCHEDULE NAILING PER (4)8d INTO EACH BLOCK HEADER/BEAM PER PLAN (MIN 12"L) AT 48"oc JOIST OR BLOCK (2)10d THRU EA PROVIDE I-JOIST BLKG WHERE JOISTS ARE PARALLEL NAILING PER SHEARWALL PER PLAN SHEATHING CAN BE PLACED ON EITHER SIDE OF WALL I-JOIST OR BLKG PER PLAN FOR SHEARWALL BELOW 10d AT 4"oc (BOTH SIDES WHERE OCCURS) JOIST DIRECTION AND SHEATHING PER PLAN 8d AT 4"oc ENTIRE LENGTH OF WALL (4)8d INTO EACH BLOCK JOIST DIRECTION AND SHEATHING PER PLAN HEADER/BEAM PER PLAN (MIN 12"L) AT 48"oc JOIST OR BLOCK (2)10d THRU EA PROVIDE I-JOIST BLKG WHERE JOISTS ARE PARALLEL 1-1/4" LSL RIM JOIST LEAVE (1)END UN-NAILED UNTIL PRIOR TO COVERING OR BEAM PER PLAN HOLDOWN STUDS AND POSTS VERT GRAIN BLKG TO MATCH PER SHEARWALL BELOW 2x BLKG OR NAILER w/ 10dHOLDOWN PER PLAN PANEL EDGE NAILING OVER ALL HOLDOWN STUDS 10d PER SHEARWALL BELOW SHEARWALL SCHEDULE NAILING PER SHEARWALL PER PLAN 12d AT 8"oc PANEL EDGE NAILING OVER ALL HOLDOWN STUDS EDGE NAILING OF SHEARWALL ABOVE 1'-2" MINRS HOLDOWN PER PLAN w/ (16)8d EACH END OF STRAP INTO HOLDOWN STUDS AND BEAM BELOW THF SERIES HANGER BEAM PER PLAN SHEARWALL PER PLAN JOISTS AND SHEATHING PER PLANSHEARWALL SCHEDULE NAILING PER 2'-0" MINSHEATHINGCONTSHEATHING EDGE 12d AT 8"oc 2'-0" MINPANEL EDGE NAILING OVER ALL HOLDOWN STUDS SHEATHINGCONTSHEATHING EDGE EDGE NAILING OF SHEARWALL ABOVE 1'-2" MINRS HOLDOWN PER PLAN w/ (16)8d EACH END OF STRAP INTO HOLDOWN STUDS AND BEAM BELOW 2x4 BLKG w/ 10d AT 6"oc BOTTOM FLUSH SHEARWALL PER PLAN JOISTS AND SHEATHING PER PLAN BEAM PER PLAN 8d AT 6"oc THF SERIES HANGER SHEARWALL SCHEDULE NAILING PER (4)8d INTO EACH BLOCK JOISTS AND SHEATHING PER PLAN AT 48"oc I-JOIST BLKG (MIN12"L) I-JOIST OR BEAM PER PLAN SHEARWALL PER PLAN SCHEDULE NAILING PER SHEARWALL 1'-2" MINPANEL EDGE NAILING OVER ALL HOLDOWN STUDS SHEARWALL PER PLAN (4)8d INTO EACH BLOCK JOISTS AND SHEATHING PER PLAN SIDE OF STRAP AT 48"oc AND EACH I-JOIST BLKG (MIN12"L)RS HOLDOWN PER PLAN w/ (16)8d EACH END OF STRAP INTO HOLDOWN STUDS AND BEAM BELOW BEAM PER PLAN SCHEDULE NAILING PER SHEARWALL S4.1 SCALE - NTS DETAILS WOOD FRAMINGCCOPYRIGHT 2018 MALSAM TSANG ENGINEERING CORPORATION - ALL RIGHTS RESERVEDPlotted by: johntPlotted Date: Sep 25, 2019 - 4:14pmSEATTLE III - 51-40-01.02 N PLANALU - 47 122 S JACKSON ST - SUITE 210 MALSAMTSANGSTRUCTURALENGINEERINGSEATTLE, WA 98104 - 206.789.6038 PROJECT MANAGER DRAWN DESCRIPTION PERMIT SET 9.16.19 DATE PROJECT NO 0135.2018.08.0005 TMH ENGINEER RAF ARCH PERMIT CORRECTIONS 9.25.191 REV MAINVUE HOMES 425.646.4022 RUSS FOISY 206.623.2799 RUSSF@MALSAM-TSANG.COM A 43968 TC.IVN SA N GEFO NII E SS NOA L GNE EE O RPRTASET RESIGT DE HSFWA IN GTONR 4321 8 12 765 109 11 FULL DEPTH 2x BLKG DRILL TO VENT AS REQD w/ 8d AT 6"oc FASCIA PER ARCH SHEARWALL PER PLAN FASTENMASTER TIMBERLOK (1)AT EACH OUTSIDE PLY OF MULTIPLE TRUSSES TLOK06 SCREWS EACH TRUSS HEADER/BEAM PER PLAN PER ARCH 22-1/2° SHEATHING PER PLAN PRE-MFR TRUSSES AND 10d AT 8"oc PER ARCH 3"POST AND POST CAP PER PLAN SHEATHING TO BE CONT SHEATHE AND NAIL PER SW6 FASCIA PER ARCH 22-1/2° FASTENMASTER TIMBERLOK (1)AT EACH OUTSIDE PLY OF MULTIPLE TRUSSES TLOK06 SCREWS EACH TRUSS HEADER/BEAM PER PLAN 2x4 BLKG w/ 10d AT 6"oc SHEATHING PER PLAN PRE-MFR TRUSSES AND FULL DEPTH 2x BLKG DRILL TO VENT AS REQD w/ 8d AT 6"oc 10d PER SHEARWALL SCHEDULE TO TRANSFER LOAD PER PLAN LATERALLY BETWEEN TOP AND BOT CHORD FOR ENTIRE LENGTH OF TRUSS TRUSS TO BE DESIGNED SHEARWALL PER PLAN SHEATHING PER PLAN PRE-MFR TRUSSES AND PANEL EDGE NAILING OF SHEARWALL BELOW 2x NAILER w/ 10d PER SHEARWALL SCHEDULE 7/16" OSB/PLYWOOD OVER WALL FOR ENTIRE LENGTH OF WALL TO TRANSFER LOAD PER PLAN LATERALLY BETWEEN TOP AND BOT CHORD FOR ENTIRE LENGTH OF TRUSS TRUSS TO BE DESIGNED SHEARWALL PER PLAN SHEATHING PER PLAN PRE-MFR TRUSSES AND PANEL EDGE NAILING OF SHEARWALL BELOW PANEL EDGE NAILING PER SHEARWALL SCHEDULE 2x NAILER w/ 10d PANEL EDGE NAILING PER SHEARWALL BELOW 2x4 LEDGER w/ 10d AT 6"oc 2x4 BLOCKING EA SIDE SHEATHING PER PLAN PRE-MFR TRUSSES AND (2)10d TOENAILS EA TRUSS (2)10d AT 8"oc 8d AT 6"oc S4.2 SCALE - NTS DETAILS WOOD FRAMINGCCOPYRIGHT 2018 MALSAM TSANG ENGINEERING CORPORATION - ALL RIGHTS RESERVEDPlotted by: johntPlotted Date: Sep 25, 2019 - 4:14pmSEATTLE III - 51-40-01.02 N PLANALU - 47 122 S JACKSON ST - SUITE 210 MALSAMTSANGSTRUCTURALENGINEERINGSEATTLE, WA 98104 - 206.789.6038 PROJECT MANAGER DRAWN DESCRIPTION PERMIT SET 9.16.19 DATE PROJECT NO 0135.2018.08.0005 TMH ENGINEER RAF ARCH PERMIT CORRECTIONS 9.25.191 REV MAINVUE HOMES 425.646.4022 RUSS FOISY 206.623.2799 RUSSF@MALSAM-TSANG.COM A 43968 TC.IVN SA N GEFO NII E SS NOA L GNE EE O RPRTASET RESIGT DE HSFWA IN GTONR