Loading...
HomeMy WebLinkAboutD_2019_Sunset_Terrace_Master_Plan_Minor_Mod_Exhibits_191218DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Project Location Map D_2019_Sunset_Terrace_Master_Plan_Minor_Mod_2019 A. ADMINISTRATIVE MODIFICATION REPORT & DECISION Decision: APPROVED APPROVED SUBJECT TO CONDITIONS DENIED Report Date: December 18, 2019 Project File Number: PR15-000009 Project Name: Renton Sunset Terrace Redevelopment Master Plan 2019 Minor Modification Land Use File Number: LUA14-001475,MOD Project Manager: Matt Herrera, Senior Planner Owner/Applicant: Mark Gropper, Renton Housing Authority, 2900 NE 10th St., Renton, WA 98056 Contact: Zak de Gorgue, Brawner, 35030 SE Douglas St., Suite 110, Snoqualmie, WA 98065 Project Location: Located in the Renton Highlands Planning Area, the Sunset Terrace community is generally bounded by Sunset Blvd NE on the south that forms a “U-shaped” border, Glenwood Avenue NE and NE 10th Street on the north; Harrington Avenue NE bisects the area. Project Summary: The applicant is requesting a minor modification to the approved master site plan to shift 43 units from the Edmonds site (Site C/18) to the Sunset Park West Townhomes/Harrington Park 2016/Sunset Oaks 2019 site (Sites E/14,16/17). No increase in density or other changes are proposed to the overall master site plan. Site Area: 16.83 acres DocuSign Envelope ID: 37155314-DC09-45EE-94D3-D08B4FABB1CF City of Renton Department of Community & Economic Development Renton Sunset Terrace Redevelopment Master Plan 2019 Minor Modification Administrative Modification Report & Decision LUA14-001475,MOD Report of December 18, 2019 Page 2 of 7 D_2019_Sunset_Terrace_Master_Plan_Minor_Mod_2019 B. EXHIBITS: Exhibits 1-7 Environmental Review Committee Memorandum and Exhibits Exhibit 8 Administrative Modification Decision Exhibit 9: Minor Modification Request Justification Exhibit 10: Site Plan Exhibit 11: Sunset Area Planned Action Ordinance 5813 Exhibit 12: Revised Record of Decision 2019 Exhibit 13: Adoption of Existing Environmental Document with Addendum C. PROJECT DESCRIPTION/BACKGROUND The City of Renton, along with the Renton Housing Authority (RHA), and other public, private, and nonprofit agencies and developers, is redeveloping the Sunset Terrace public housing community plus several peripheral sites that have been master planned for redevelopment along with Sunset Terrace for a total area of approximately 16 acres. The Renton Sunset Terrace Redevelopment Master Site Plan envisions a mixed-use, mixed-income community with park, library, and other civic and commercial uses. Mixed-use sites will have both market rate and affordable rental housing in multi-story, multi-family townhomes and apartments, along with commercial and retail space. The Renton Sunset Terrace Redevelopment Master Site Plan area (Exhibit 10) was the subject of evaluations and addenda in 2014 and 2016. The master plan completed in 2014 (Exhibit 6) provides a coordinated plan of development for both the Sunset Terrace and Replacement sites. The 2016 minor modification to the master plan (Exhibit 5) added properties into the master plan, and redistributed some dwelling units, but retained the same overall number of units as approved by the 2014 master plan. The applicant has requested a new minor modification to the master plan (Exhibit 8) that would shift 43 units between a site on the west (Site C/18: Edmonds Apartments/Homestead Willow Crest Townhomes) to a site in the north of the Master Site Plan area (Site E/14,16/17: Sunset Park West Townhomes 2014/Harrington Park 2016/Sunset Oaks 2019). The Edmonds site was recently entitled with a Planned Urban Development that developed the western portion of the site into 12 townhomes on individual fee simple lots with access and open space tracts leaving a 0.94 acre lot on the western portion of the site for future development. The 2019 Reevaluation/Addendum (Exhibit 2) also assesses the future removal of a site from the master plan boundaries (Site G/11 known previously as the Sunset Park East (Piha) Townhomes & Apartments 2014/Suncrest Homes 2016/Solera 2019). The site would remain within the Sunset Area Community neighborhood. This master plan boundary amendment proposal is evaluated for potential implementation at a later date. It would require a major modification to the approved master plan and Planned Action Ordinance amendment when accomplished. The reevaluation identifies implications of the site’s future removal should the City, RHA, or Solera applicant desire that amendment. The 2019 minor modification request would not add housing units in the master plan area or in the Sunset Area neighborhood. However, consistent with the flexibility allowed by the adopted master plan, some units would be redistributed. DocuSign Envelope ID: 37155314-DC09-45EE-94D3-D08B4FABB1CF City of Renton Department of Community & Economic Development Renton Sunset Terrace Redevelopment Master Plan 2019 Minor Modification Administrative Modification Report & Decision LUA14-001475,MOD Report of December 18, 2019 Page 3 of 7 D_2019_Sunset_Terrace_Master_Plan_Minor_Mod_2019 D. FINDINGS OF FACT (FOF): 1. The Renton Sunset Terrace Redevelopment Master Site Plan was approved on January 14, 2015 subject to four conditions of approval (Exhibit 6): a. A Development/Density Transfer Agreement shall be executed by the City and Colpitts prior to detailed Site Plan Review approval for any phase of development which intends to utilize unused residential density from the proposed park acreage. b. All phases included in the Master Site Plan shall comply with the Sunset Area Street Classification Map. Conceptual frontage improvements shall be submitted at the time of Site Plan Review for each phase and are subject to approval by the Current Planning Project Manager and Plan Reviewer. c. Prior to beginning construction, each individual project phase or improvement shall provide information to surrounding property owners about timelines, extent of construction, and contact information. d. The decision is effective until January 14, 2025. 2. A minor modification of the master plan was approved June 20, 2016 (Exhibit 5) that included the following changes: a. Shift seven units from the Sunset Terrace Apartments (Site D/5) to the Sunset Park East (Piha) Townhomes & Apts (a.k.a. Suncrest) property (Site G/11); and b. Develop replacement housing for the RHA Sunset Terrace Redevelopment on five parcels located outside but abutting the 2014 master plan area. Three (3) parcels were added to the Sunset Court Park site (Site F/19) and developed with 50 apartments and townhomes (LUA16-000068), and two parcels would be added to properties north of the “loop road” in the Sunset Park West Townhomes development resulting in 19 townhomes (Site E/14, 16,17 Sunset Park West Townhomes 2014/Harrington Park 2016 ). c. Conditions associated with the 2016 minor modification have been met. 3. The proposed 2019 minor modification to the master plan would shift 43 units from the Edmonds Site (Site C/18) to the Sunset Oaks site (Site E/14,16/17: Sunset Park West Townhomes 2014/Harrington Park 2016/Sunset Oaks 2019). 4. The summary of total dwelling units proposed to be shifted and the history of the 2014 and 2016 total dwelling counts are illustrated in the following table: DocuSign Envelope ID: 37155314-DC09-45EE-94D3-D08B4FABB1CF City of Renton Department of Community & Economic Development Renton Sunset Terrace Redevelopment Master Plan 2019 Minor Modification Administrative Modification Report & Decision LUA14-001475,MOD Report of December 18, 2019 Page 4 of 7 D_2019_Sunset_Terrace_Master_Plan_Minor_Mod_2019 5. The proposed 2019 minor modification to the approved Renton Sunset Terrace Redevelopment Master Plan would result in no net increase in dwelling units to the master plan area. 6. The Edmonds site was recently entitled with a Planned Urban Development and Binding Site Plan (LUA19- 000061) that subdivided the site into 13-lots and two (2) tracts to construct 12 townhomes on fee simple lots reserving the eastern 0.94 acres for future development. The recent entitlement and shift in units will result in lower density development on the Edmonds site versus the initial master plan approval that envisioned higher density apartment flats. 7. The land use designation and zoning classification for the Sunset Oaks site was recently amended from Residential High Density to Commercial Mixed Use and Residential-14 to Center Village, respectively. This zoning change resulted in the opportunity to develop the Sunset Oaks site at higher densities than the initial master plan approval that envisioned the site to contain townhomes. 8. The 2019 NEPA/SEPA Reevaluation (Exhibit 2) assesses the future removal of a site from the master plan boundaries (Site G/11 known previously as the Sunset Park East (Piha) Townhomes & Apartments 2014/Suncrest Homes 2016/Solera 2019). The site would remain within the Sunset Area Community neighborhood. It would require a major modification to the approved master plan and Planned Action Ordinance amendment when accomplished. 9. The master plan area is located within the Sunset Planned Action Area where a Planned Action Ordinance (Ord. 5813) (Exhibit 11) was adopted in accordance with the State Environmental Policy Act (SEPA) for redevelopment of the Highlands Area. The Final EIS document was issued April 1, 2011 (Exhibit 7). 10. The Environmental Review Committee (ERC) reviewed the minor modification request (Exhibit 1) and issued a revised Record of Decision (Exhibit 12) and adopted an Existing Environmental Document with Addendum (Exhibit 13). 11. The Planning Division of the City of Renton accepted the above master application for review on November 10, 2019 and determined the application complete on November 13, 2019. The project complies with the 120-day review period. 12. The applicant’s submittal materials comply with the requirements necessary to process the modification request (see exhibit list). Neighbor- hood Site Letter Master Plan Site Development Title Status Acres: 2014 Total Units Reviewed in Reevaluation: 2014 Acres: 2016 Total Units Reviewed in Reevaluation: 2016 Acres: 2019 Total Units Reviewed in Reevaluation: 2019 A Glennwood Townhomes Constructed RHA 0.65 8 0.65 8 0.65 8 B Kirkland Avenue Townhomes Constructed RHA 0.77 18 0.77 18 0.77 18 C 18 Edmonds Apartments/Sunset Crest Part of Master Site Plan 1.70 112 1.70 68 1.70 25 D 5 Sunset Terrace Apartments Part of Master Site Plan 0.51 54 0.51 47 0.51 47 E 14, 16/17 Sunset Park West Townhomes 2014 / Harrington Park 2016/ Sunset Oaks 2019 Part of Master Site Plan 0.55 10 1.06 19 1.05 62 F 19 Sunset Court Townhomes 2014 / Sunset Court Apartments 2016 Part of Master Site Plan 0.88 15 1.95 50 1.95 50 G 11 Sunset Park East (Piha) Townhomes & Apts 2014 / Suncrest Homes 2016 / Solera 2019 Part of Master Site Plan (Remove in Future)1.09 57 1.09 64 1.09 64 H 9 Sunset Terrace Dev. Building A Part of Master Site Plan 0.99 117 0.99 117 0.58 117 I 7/8 Sunset Terrace Dev. Building B Part of Master Site Plan 1.18 196 1.18 196 1.18 196 J 6/7 Sunset Terrace Dev. Building C Part of Master Site Plan 0.74 110 0.74 110 0.74 110 K 10 Renton Highlands Library Constructed, King County Library System See H See H 0.37 L Regional Stormwater Facility Constructed, City See M See M See M M Sunset Park Consturcted, City 3.20 3.2 3.2 N Sunset Lane Loop Improvements Constructed, City 1.41 1.41 1.41 O NE 10th Street Extension Improvements Constructed, City 0.20 0.20 0.20 X Library Site (2013)Future Development 1.41 25 1.41 25 1.41 25 Total - Master Plan Sites 12.44 671 14.04 671 13.99 671 Total - All Sites 15.28 722 16.88 722 16.83 722 = Master Plan Properties DocuSign Envelope ID: 37155314-DC09-45EE-94D3-D08B4FABB1CF City of Renton Department of Community & Economic Development Renton Sunset Terrace Redevelopment Master Plan 2019 Minor Modification Administrative Modification Report & Decision LUA14-001475,MOD Report of December 18, 2019 Page 5 of 7 D_2019_Sunset_Terrace_Master_Plan_Minor_Mod_2019 13. The master plan site is located in the Renton Highlands Planning Area, the Sunset Terrace community is generally bounded by Sunset Blvd NE on the south that forms a “U-shaped” border, Glenwood Avenue NE and NE 10th Street on the north; Harrington Avenue NE bisects the area. 14. The project site is currently developed with library, Sunset Neighborhood Park, Sunset Lane/NE 10th street improvements, and Sunset Court Apartments. 15. The property is located within Commercial Mixed Use land use designation. 16. The site is located within the Center Village (CV) zoning classification. 17. Representatives from various city departments have reviewed the application materials to identify and address issues raised by the proposed development. These comments are contained in the official file, and the essence of the comments has been incorporated into the appropriate sections of this report and the Departmental Recommendation at the end of this report. 18. Site Plan Modification Analysis: The applicant is requesting a site plan modification in order to shift 43 dwelling units from the Edmonds Site (Site C/18) to the Sunset Oaks site (Site E/14,16/17: Sunset Park West Townhomes 2014/Harrington Park 2016/Sunset Oaks 2019). The proposed shift in units would result in the Edmonds site containing 25 available dwelling units and the Sunset Oaks site containing 62 available dwelling units. The proposal is compliant with the following modification criteria, pursuant to RMC 4-9- 200.H.2, provided the condition of approval is met. Therefore, staff is recommending approval of the requested modification, subject to the condition noted in the Decision section below: Compliance Modification Criteria and Analysis  a. Involve more than a ten percent (10%) increase in area or scale of the development in the approved plan. Staff Comment: There would be no increase in the scale of the development. No new units to the master plan are proposed. Any administrative site plan review applications submitted for review on a master plan site would be required to comply with the building heights and coverage standards that were adopted as part of the master site plan decision.  b. Have a significantly greater impact on the environment and/or public facilities than the approved plan; or Staff Comment: The 2019 NEPA/SEPA Reevaluation (Exhibit 4) identifies similar impacts and mitigation measures as the 2011 EIS (Exhibit 7), and the 2014 and 2016 Reevaluations (Exhibits 5 and 6). There is no change in the applicable Planned Action Ordinance mitigation measures.  c. Change the boundaries of the originally approved plan. Staff Comment: The proposed minor modification would not result in changes to the boundaries of the approved Renton Sunset Terrace Redevelopment Master Site Plan (Exhibit 10). In the future, the City, RHA, or Solera applicant may propose the removal of Site G/11 (also known as Piha). Such a change would require a major modification to the approved master plan. The 2019 Reevaluation (Exhibit 4) addresses the implications of this change, which show no change to overall goals for the neighborhood or the environmental review. DocuSign Envelope ID: 37155314-DC09-45EE-94D3-D08B4FABB1CF City of Renton Department of Community & Economic Development Renton Sunset Terrace Redevelopment Master Plan 2019 Minor Modification Administrative Modification Report & Decision LUA14-001475,MOD Report of December 18, 2019 Page 6 of 7 D_2019_Sunset_Terrace_Master_Plan_Minor_Mod_2019 E. DECISION: The proposal satisfies three (3) of the three (3) criteria listed in RMC 4-9-200H.2 for approval of modifications. Therefore, the Renton Sunset Terrace Redevelopment Master Plan 2019 Minor Modification, File No. LUA14- 001475,MOD, is approved and is subject to the following conditions: 1. Conditions of approval from the 2015 Renton Sunset Terrace Redevelopment Master Site Plan decision continue as part of this minor modification decision. DATE OF DECISION ON LAND USE ACTION: SIGNATURE: Jennifer Henning, Planning Director Date TRANSMITTED on December 18, 2019 to the Owner/Applicant/Contact: Owner: Applicant: Mark Gropper, Renton Housing Authority, 2900 NE 10th St., Renton, WA 98056 Zak de Gorgue, Brawner, 35030 SE Douglas St, Suite 110, Snoqualmie, WA 98065 TRANSMITTED on December 18, 2019 to the Parties of Record: Name and address TRANSMITTED on December 18, 2019 to the following: Chip Vincent, CED Administrator Brianne Bannwarth, Development Engineering Manager Amanda Askren, Property Services Vanessa Dolbee, Current Planning Manager Rick Marshall, Fire Marshal K. LAND USE ACTION APPEALS, REQUEST FOR RECONSIDERATION, & EXPIRATION: The administrative land use decision will become final if the decision is not appealed within 14 days of the decision date. APPEAL: This administrative land use decision will become final if not appealed in writing to the Hearing Examiner on or before 5:00 PM on January 2, 2019. An appeal of the decision must be filed within the 14-day appeal period (RCW 43.21.C.075(3); WAC 197-11-680), together with the required fee to the Hearing Examiner, City of Renton, 1055 South Grady Way, Renton, WA 98057. RMC 4-8-110.B governs appeals to the Hearing Examiner and additional information regarding the appeal process may be obtained from the City Clerk’s Office, (425) 430-6510. RECONSIDERATION: Within 14 days of the decision date, any party may request that the decision be reopened by the approval body. The approval body may modify his decision if material evidence not readily discoverable prior to the original decision is found or if he finds there was misrepresentation of fact. After review of the DocuSign Envelope ID: 37155314-DC09-45EE-94D3-D08B4FABB1CF 12/18/2019 | 2:31 PM PST City of Renton Department of Community & Economic Development Renton Sunset Terrace Redevelopment Master Plan 2019 Minor Modification Administrative Modification Report & Decision LUA14-001475,MOD Report of December 18, 2019 Page 7 of 7 D_2019_Sunset_Terrace_Master_Plan_Minor_Mod_2019 reconsideration request, if the approval body finds sufficient evidence to amend the original decision, there will be no further extension of the appeal period. Any person wishing to take further action must file a formal appeal within the 14-day appeal time frame. THE APPEARANCE OF FAIRNESS DOCTRINE: provides that no ex parte (private one-on-one) communications may occur concerning the land use decision. The Doctrine applies not only to the initial decision, but to Appeals to the Hearing Examiner as well. All communications after the decision/approval date must be made in writing through the Hearing Examiner. All communications are public record and this permits all interested parties to know the contents of the communication and would allow them to openly rebut the evidence in writing. Any violation of this doctrine could result in the invalidation of the appeal by the Court. DocuSign Envelope ID: 37155314-DC09-45EE-94D3-D08B4FABB1CF CITY OF RENTON DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT ADMINISTRATIVE MODIFICATION REPORT & DECISION EXHIBITS Project Name: Renton Sunset Terrace Redevelopment Master Plan 2019 Minor Modification Land Use File Number: LUA14-001475,MOD Date of Report December 18, 2019 Staff Contact Matt Herrera Senior Planner Project Contact/Applicant Zak de Gorgue Brawner 35030 SE Douglas St., Suite 110, Snoqualmie, WA 98065 Project Location Sunset Terrace NeighborhoodError! Reference source not found. The following exhibits are included with the Administrative Modification Report: Exhibits 1-7 Environmental Review Committee Memorandum and Exhibits Exhibit 8 Administrative Modification Decision Exhibit 9: Minor Modification Request Justification Exhibit 10: Site Plan Exhibit 11: Sunset Area Planned Action Ordinance 5813 Exhibit 12: Revised Record of Decision 2019 Exhibit 13: Adoption of Existing Environmental Document with Addendum DocuSign Envelope ID: 37155314-DC09-45EE-94D3-D08B4FABB1CF DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT ENVIRONMENTAL REVIEW COMMITTEE MEMO APPLICATION NUMBER: LUA14-001475, MOD APPLICANTS: Mark Gropper, Renton Housing Authority, 2900 NE 10th St, Renton, WA 98056 PROJECT NAME: PR15000009 Sunset Terrace Redevelopment Master Plan – Minor Modification (2019 Reevaluation and Addendum) LOCATION OF PROPOSAL: Located in northeast Renton, the Sunset Terrace community is generally bounded by Sunset Blvd NE on the south that forms a “U-shaped” border, Glenwood Avenue NE and NE 10th Street on the north; Harrington Avenue NE bisects the area. LEAD AGENCY/RESPONSIBLE ENTITY: City of Renton, Environmental Review Committee STAFF RECOMMENDATION: Issue the ROD Reevaluation and Addendum and Adopt Existing Environmental Document BACKGROUND: The City of Renton, along with the Renton Housing Authority (RHA), and other public, private, and nonprofit agencies and developers, is redeveloping the Sunset Terrace public housing community totaling approximately 13 acres. The Master Site Plan envisions a mixed-use, mixed-income community with park and library and other civic and commercial uses. Mixed-use sites will have both market rate and affordable rental housing in multi-story, multi-family townhomes and apartments, along with commercial and retail space. In order to meet National Environmental Policy Act (NEPA) and State Environmental Policy Act (SEPA) requirements, the City of Renton issued the Draft Environmental Impact Statement (DEIS) for the City of Renton Sunset Area Community Planned Action on December 17, 2010 and the Final Environmental Impact Statement (FEIS) for the City of Renton Sunset Area Community Planned Action on April 1, 2011. The City served as the Responsible Entity (RE) for NEPA compliance, and the lead agency for SEPA compliance. The Sunset Terrace Master Site Plan Area was also the subject of subsequent revaluations/addenda in 2014 and 2016. The Master Site Plan completed in 2014 provides a coordinated plan of development for both the Sunset Terrace and Replacement sites. The 2016 Master Site Plan amendment added properties into the Master Site Plan, and redistributed some dwelling units, but retained the same overall number of units as approved by the 2014 Master Site Plan. PROJECT SUMMARY: RHA has proposed a minor modification to the approved master site plan that would shift allocated units from the Edmonds site (site C/18) Edmonds to Sunset Oaks (site E/14, 16/17). A Comprehensive Plan amendment and rezone was adopted last year changed the Sunset Oaks property located at 1073 Harrington Ave NE from the Residential-14 (R-14) zone to Center Village (CV) zone. Initially, the master plan envisioned the Edmonds site to include an apartment flat style building and the Sunset Oaks site as a townhome development. With the change in zoning on the Sunset Oaks site, RHA has decided to increase the density and shift 43 dwelling units from the Edmonds site to Sunset Oaks site resulting in 62 total units on Sunset Oaks and 25 units on Edmonds. The eastern portion of the Edmonds site was recently entitled (Willowcrest Townhomes) and is nearing the groundbreaking to construct the City’s first affordable homeownership project. The Sunset Oaks property would construct apartment flats in three (3) buildings that is anticipated to break ground in spring 2020. No net additions to the 722 total dwellings analyzed in the previous 2014 and 2016 reevaluation of Sunset Terrace Redevelopment Master Site Plan are proposed. No other changes to the master site plan other than the shift in units are proposed at this time, however the reevaluation and addendum (Exhibit 2) does anticipate a potential removal of the Piha site (site G/11) associated with the Solera Master Site Plan (former Hi-Lands Shopping Center). The removal of the Piha site will require a major modification to the Sunset Terrace Redevelopment Master Site Plan and Planned Action Ordinance amendment when the Solera applicant chooses to move forward with future administrative entitlements. Summary of Total Units Proposed for Study in Reevaluation Neighbor- hood Site Letter Master Plan Site Development Title Status Acres: 2014 Total Units Reviewed in Reevaluation: 2014 Acres: 2016 Total Units Reviewed in Reevaluation: 2016 Acres: 2019 Total Units Reviewed in Reevaluation: 2019 A Glennwood Townhomes Constructed RHA 0.65 8 0.65 8 0.65 8 B Kirkland Avenue Townhomes Constructed RHA 0.77 18 0.77 18 0.77 18 C 18 Edmonds Apartments/Sunset Crest Part of Master Site Plan 1.70 112 1.70 68 1.70 25 D 5 Sunset Terrace Apartments Part of Master Site Plan 0.51 54 0.51 47 0.51 47 E 14, 16/17 Sunset Park West Townhomes 2014 / Harrington Park 2016/ Sunset Oaks 2019 Part of Master Site Plan 0.55 10 1.06 19 1.05 62 F 19 Sunset Court Townhomes 2014 / Sunset Court Apartments 2016 Part of Master Site Plan 0.88 15 1.95 50 1.95 50 G 11 Sunset Park East (Piha) Townhomes & Apts 2014 / Suncrest Homes 2016 / Solera 2019 Part of Master Site Plan (Remove in Future)1.09 57 1.09 64 1.09 64 H 9 Sunset Terrace Dev. Building A Part of Master Site Plan 0.99 117 0.99 117 0.58 117 I 7/8 Sunset Terrace Dev. Building B Part of Master Site Plan 1.18 196 1.18 196 1.18 196 J 6/7 Sunset Terrace Dev. Building C Part of Master Site Plan 0.74 110 0.74 110 0.74 110 K 10 Renton Highlands Library Constructed, King County Library System See H See H 0.37 L Regional Stormwater Facility Constructed, City See M See M See M M Sunset Park Consturcted, City 3.20 3.2 3.2 N Sunset Lane Loop Improvements Constructed, City 1.41 1.41 1.41 O NE 10th Street Extension Improvements Constructed, City 0.20 0.20 0.20 X Library Site (2013)Future Development 1.41 25 1.41 25 1.41 25 Total - Master Plan Sites 12.44 671 14.04 671 13.99 671 Total - All Sites 15.28 722 16.88 722 16.83 722 = Master Plan Properties Edmonds Sunset Oaks Piha DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT CITY OF RENTON DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT STAFF REPORT TO THE ENVIRONMENTAL REVIEW COMMITTEE EXHIBITS Project Name: PR15000009 Sunset Terrace Redevelopment Master Plan – Minor Modification (2019 Reevaluation and Addendum) Project Number: LUA19-001475, MOD Date of Meeting December 9, 2019 Staff Contact Matt Herrera Senior Planner Project Contact Mark Gropper, Renton Housing Authority, 2900 NE 10th St, Renton, WA 98056 Project Location Sunset Terrace The following exhibits are included with the ERC Report: Exhibit 1: Environmental Review Committee (ERC) Memo Exhibit 2: Renton Sunset Terrace Redevelopment Reevaluation/Addendum prepared by Berk Consulting and Transpo Group dated August 2019 Exhibit 3: Impervious Surfaces Analysis, prepared by Berk Consulting dated August 2019 Exhibit 4: Transportation Analysis Memorandum, prepared Transpo Group dated July 23, 2019 Exhibit 5: Master Site Plan 2016 Exhibit 6: Master Site Plan 2014 Exhibit 7: Final EIS August 2019 | Renton Sunset Community Area Reevaluation and Addendum 1 Reevaluation / Addendum Renton Sunset Terrace Redevelopment | August 2019 Prepared By: BERK Consulting in association with Transpo Group 1 Background/Need for Reevaluation .................................................................................... 2 2 Sunset Area Alternatives ..................................................................................................... 6 2.1 Study Area ........................................................................................................................................ 6 2.2 Land Use Proposals ......................................................................................................................... 8 2.3 Development Standards ............................................................................................................... 11 2.4 Facility and Infrastructure Proposals .......................................................................................... 13 2.5 Updated Land Cover / Impervious Analysis ............................................................................. 13 2.6 Phasing ............................................................................................................................................. 15 2.7 Master Site Plan and Other Discretionary Applications ......................................................... 16 3 Environmental Analysis ....................................................................................................18 3.1 Land Use .......................................................................................................................................... 18 3.2 Aesthetics ......................................................................................................................................... 18 3.3 Cultural Resources .......................................................................................................................... 18 3.4 Transportation................................................................................................................................. 18 3.5 Parks and Recreation .................................................................................................................... 18 3.6 Public Services ................................................................................................................................ 18 3.7 Utilities .............................................................................................................................................. 18 3.8 Other FEIS Topics ........................................................................................................................... 19 3.9 Monitoring and Review ................................................................................................................. 19 4 Conclusions .......................................................................................................................23 Attachments Attachment A Transportation Analysis - Reevaluation August 2019 | Renton Sunset Community Area Reevaluation and Addendum 2 1 Background/Need for Reevaluation The City of Renton, along with the Renton Housing Authority (RHA), and other public, private, and nonprofit agencies and developers, is redeveloping the Sunset Terrace public housing community plus some peripheral sites that have been master planned for redevelopment along with Sunset Terrace for a total of about 12.7 acres. See Exhibit 1. The Master Site Plan envisions a mixed-use, mixed-income community with park and library and other civic and commercial uses. Mixed-use sites will have both market rate and affordable rental housing in multi-story, multi-family townhomes and apartments, along with commercial and retail space. The Master Site Plan is located within the Renton Sunset neighborhood that has been included in the Renton Comprehensive Plan as a center for new housing, commercial, recreation, education, and other uses. See Exhibit 2. In order to meet National Environmental Policy Act (NEPA) and State Environmental Policy Act (SEPA) requirements, the City of Renton issued the Draft Environmental Impact Statement (DEIS) for the City of Renton Sunset Area Community Planned Action on December 17, 2010 and the Final Environmental Impact Statement (FEIS) for the City of Renton Sunset Area Community Planned Action on April 1, 2011.1 The City served as the Responsible Entity (RE) for NEPA compliance, and the lead agency for SEPA compliance. The Sunset Terrace Master Site Plan Area was also the subject of subsequent revaluations/addenda in 2014 and 2016. The Master Site Plan completed in 2014 provides a coordinated plan of development for both the Sunset Terrace and Replacement sites. The 2016 Master Site Plan amendment added properties into the Master Site Plan, and redistributed some dwelling units, but retained the same overall number of units as approved by the 2014 Master Site Plan. See Exhibit 3 for the Sunset Terrace redevelopment area and housing replacement sites. In 2019, RHA2 is proposing an amended Master Site Plan that would:  Shift units between a site on the west (Site C/18: Edmonds Apartments/Homestead Willow Crest Townhomes) to a site in the north of the Master Site Plan area (Site E/14,16/17: Sunset Park West Townhomes 2014/Harrington Park 2016/Sunset Oaks 2019). This 2019 reevaluation also assesses the future removal of a site from the Master Site Plan boundaries (Site G/11 known previously as the Sunset Park East (Piha) Townhomes & Apartments 2014/Suncrest Homes 2016/Solera 2019). The site would remain within the Sunset Area Community neighborhood. This Master Site Plan boundary amendment proposal is evaluated for potential implementation at a later date. It would require a Major Site Plan amendment and Planned Action Ordinance (PAO) amendment when accomplished. The reevaluation identifies implications of the site’s future removal should the City or RHA desire that amendment. The 2019 proposals would not add housing units in the Master Site Plan area or in the Sunset Area neighborhood. However, consistent with the flexibility allowed by the adopted Master Site Plan, some units would be redistributed. 1 CH2MHill and ICF International. 2011. Sunset Area Community Planned Action NEPA/SEPA Environmental Impact Statement. Final. April. (ICF 00593.10.) Bellevue and Seattle, WA. Prepared for City of Renton and the Renton Housing Authority, Renton, WA. 2 RHA owns Sites C and E. The applicant for Site E is Sunset Oakes LLLP. August 2019 | Renton Sunset Community Area Reevaluation and Addendum 3 As amended, development in the Master Site Plan area would meet City standards for density, height, setbacks, transportation levels of service, connection to utilities, and would be subject to City parking codes, including procedures for modifying applicable standards. The amended Master Site Plan would be consistent with RMC Title IV. Also, the SEPA PAO would be amended in the future to include the revised Master Site Plan concept should Site G/11 (Solera) site be removed. The total development levels and mitigation measures in the PAO remain unchanged. Exhibit 1. Sunset Terrace Master Site Plan 2016 Source: Mithun, City of Renton 2016 August 2019 | Renton Sunset Community Area Reevaluation and Addendum 4 Exhibit 2. Planned Action Area: 2011 Source: CH2MHill and ICF International, 2011; BERK, 2016. August 2019 | Renton Sunset Community Area Reevaluation and Addendum 5 Exhibit 3. Renton Sunset Terrace Redevelopment Area and Swap Sites: 2016 Source: CH2MHill and ICF International, 2011; BERK, 2016. August 2019 | Renton Sunset Community Area Reevaluation and Addendum 6 As with the changes previously evaluated in 2014 and 2016, the 2019 revisions proposed to the Master Site Plan at this time are the focus of this NEPA Reevaluation and SEPA Addendum to provide additional information about the proposal, to determine whether the proposed changes would result in any new or substantially different environmental impacts, and to assess whether the conclusions of the original EIS are still valid. This analysis would also provide the basis for amendments to the Record of Decision (ROD) and/or PAO, if any. This Reevaluation and Addendum document is structured as follows: 1. Introduction 2. Sunset Area Alternatives 3. Environmental Analysis 4. Conclusions 2 Sunset Area Alternatives 2.1 STUDY AREA The primary Sunset Terrace redevelopment area as well as housing Replacement sites, and areas of public investment are illustrated on Exhibit 4. All Master Site Plan sites, plus the Sunset Area neighborhood, were evaluated in the 2011 EIS for the Sunset Area Community Planned Action Area. See Exhibit 5. The 2014 Master Site Plan area totaled about 12.4 acres. The updated 2016 Master Site Plan area equaled about 14 acres. In this 2019 reevaluation, the Master Site Plan area is about 14 acres with the same sites, or 12.9 acres if Site G/11 is removed. Exhibit 4. Lettered Master Plan Sites # - Master Plan Sites /// - Sunset Terrace Public Housing Boundaries August 2019 | Renton Sunset Community Area Reevaluation and Addendum 7 Exhibit 5. Revitalization Projects: 2019 August 2019 | Renton Sunset Community Area Reevaluation and Addendum 8 2.2 LAND USE PROPOSALS In total, 722 dwelling units are being proposed in the study area in this 2019 Reevaluation, which is to the same as the number of units considered in the 2014 and 2016 Reevaluations. See Exhibit 6. Future commercial square feet are the same for each Master Site Plan Reevaluation. The Master Site Plan acres vary between the alternatives with more added in 2016 compared with 2014. In 2019, the total acres are similar to 2016, with slight adjustments due to the availability of specific site plans completed since 2016. If Site G/11 is removed, the acres would equal 15.74 closer to the 2014 Master Site Plan extent. Exhibit 6. Summary of Total Units, Commercial Square Feet, and Acres: Studied in Reevaluation Location See Exhibit 4 for Site Letters Total Dwelling Units: 2014, 2016, 2019 Commercial Square Feet: 2014, 2016, 2019 Land Area (acres): 2014 Land Area (acres): 2016 Land Area (acres): 2019 Master Site Plan Sites Sunset Terrace and Replacement Sites: C through J 671 4,500- 39,500 7.63 9.23 9.17 Library (Site K), Developed 15,000 Sunset Park (Site M) and Regional Stormwater Facility (Site L), Installed 3.20 3.20 3.21 NE 10th and Sunset Lane Loop (Site N and O) 1.61 1.61 1.61 Total Master Site Plan Sites 19,500- 54,500 12.44 14.04 13.99 Other Sunset Terrace Study Area Sites: Glenwood (Site A) - Developed 671 0.65 0.65 0.65 Swap Sites: Kirkland Avenue (B) - Developed, Library Site for Future Surplus (X) 8 2.18 2.18 2.18 Other Employment potential in Sunset Terrace and Replacement Sites 43 4,500 Total All Sites 722 19,500- 59,000 15.28 16.88 16.83 Source: King County Assessor; ICF Jones & Stokes et al. 2011; BERK Consulting 2015 and 2019 Two alternatives were addressed in the NEPA Record of Decision (ROD) and the PAO as “selected” alternatives: Alternative 3 and a Preferred Alternative. See Exhibit 7 for a list of net dwelling units. These alternatives represented the higher growth levels studied in the EIS. The mitigation documents contained in the ROD and PAO were based on the range of growth of the two Selected Sunset Area Alternatives. August 2019 | Renton Sunset Community Area Reevaluation and Addendum 9 Exhibit 7. Comparison of Net Growth in Sunset Terrace and Neighborhood Alternatives Dwelling Units/Jobs Net New Growth FEIS Alternative 3 FEIS Preferred Alternative Reevaluation Alternative: 2014 Reevaluation Alternative: 2016, 2019 Neighbor -hood Sunset Terrace Neighbor -hood Sunset Terrace Neighbor -hood Sunset Terrace Neighbor -hood Sunset Terrace Dwelling units 2,506 479c 2,339 266a 2,506 554b 2,506 519b Population 5,789 1,106 5,403 614a 5,789 1,279 5,789 1,199 Employment SF 1,310,113 59,000 1,247,444 – 1,259,944 38,100 1,310,113 19,500- 59,000 1,310,113 19,500- 59,000 Jobs 3,330 182 3,154– 3,192 117 3,330 60-182 3,330 60-182 a Does not include approximately 90-100 units to be developed on land swap/housing replacement sites. b Similar to the FEIS, includes the sites shaded purple in Exhibit 2 and Exhibit 3, considered Potential Sunset Terrace Redevelopment subarea. This equates to Master Site Plan sites C, D, E, G to O, plus site A. Sites B, F, and X considered swap sites and included within neighborhood dwelling units. C Does not include swap sites B, F, and X. Source: FEIS 2011, BERK 2014, 2016, 2019. The purpose of identifying two “Selected Sunset Area Alternatives” in the FEIS was to define a range of acceptable growth and designs considering the conceptual nature of the Sunset Terrace redevelopment plans in 2011, as well as the 20-year horizon of the broader neighborhood planned action. The Preferred Alternative was similar to Alternative 3 with slightly lower growth and a reconfiguration of park space and road network. The two alternatives were similar in terms of potential beneficial and adverse impacts and required mitigation measures. Since the original FEIS analysis, additional site planning for Sunset Terrace and other properties has occurred and some changes in the number or location of units have been considered. In 2014, 90 units were added to in the Sunset Terrace Master Site Plan area (Exhibit 8), compared to Alternative 3 in the FEIS, but the total number of units in the overall Sunset Area neighborhood remained the same. As well, other site planning considerations were addressed regarding building height, etc. as described above. The NEPA/SEPA Reevaluation conducted in 2014 showed no substantive changes in impacts or required mitigation were needed as a result of the revised alternative, which is termed the “Reevaluation Alternative.” Per the approved 2014 Master Site Plan, dwelling units may be redistributed among sites provided the Reevaluation conclusions are maintained. The net units in Sunset Terrace are lower in 2016 and 2019 than in 2014 per Exhibit 7. This is a reflection of the boundaries of the 2011 Potential Sunset Terrace Redevelopment Area (sites shaded purple in Exhibit 2 and Exhibit 3) that excluded Site 19 (also lettered Site F). Site F/19 is included in the Sunset Area neighborhood units. Some potential dwelling units are proposed to be transferred among five individual Master Site Plan sites; these are identified with the “box” on Exhibit 8. However, the total number of units that could be developed in the Master Site Plan area would remain the same. August 2019 | Renton Sunset Community Area Reevaluation and Addendum 10 Exhibit 8. Summary of Total Units Proposed for Study in Reevaluation Sources: Veer, Schemata, Third Place Design, Mithun, Colpitts, City of Renton, Renton Housing Authority, BERK 2014, 2016, 2019 Neighbor- hood Site Letter Master Plan Site Development Title Status Acres: 2014 Total Units Reviewed in Reevaluation: 2014 Acres: 2016 Total Units Reviewed in Reevaluation: 2016 Acres: 2019 Total Units Reviewed in Reevaluation: 2019 A Glennwood Townhomes Constructed RHA 0.65 8 0.65 8 0.65 8 B Kirkland Avenue Townhomes Constructed RHA 0.77 18 0.77 18 0.77 18 C 18 Edmonds Apartments/Sunset Crest Part of Master Site Plan 1.70 112 1.70 68 1.70 25 D 5 Sunset Terrace Apartments Part of Master Site Plan 0.51 54 0.51 47 0.51 47 E 14, 16/17 Sunset Park West Townhomes 2014 / Harrington Park 2016/ Sunset Oaks 2019 Part of Master Site Plan 0.55 10 1.06 19 1.05 62 F 19 Sunset Court Townhomes 2014 / Sunset Court Apartments 2016 Part of Master Site Plan 0.88 15 1.95 50 1.95 50 G 11 Sunset Park East (Piha) Townhomes & Apts 2014 / Suncrest Homes 2016 / Solera 2019 Part of Master Site Plan (Remove in Future)1.09 57 1.09 64 1.09 64 H 9 Sunset Terrace Dev. Building A Part of Master Site Plan 0.99 117 0.99 117 0.58 117 I 7/8 Sunset Terrace Dev. Building B Part of Master Site Plan 1.18 196 1.18 196 1.18 196 J 6/7 Sunset Terrace Dev. Building C Part of Master Site Plan 0.74 110 0.74 110 0.74 110 K 10 Renton Highlands Library Constructed, King County Library System See H See H 0.37 L Regional Stormwater Facility Constructed, City See M See M See M M Sunset Park Consturcted, City 3.20 3.2 3.2 N Sunset Lane Loop Improvements Constructed, City 1.41 1.41 1.41 O NE 10th Street Extension Improvements Constructed, City 0.20 0.20 0.20 X Library Site (2013)Future Development 1.41 25 1.41 25 1.41 25 Total - Master Plan Sites 12.44 671 14.04 671 13.99 671 Total - All Sites 15.28 722 16.88 722 16.83 722 = Master Plan Properties August 2019 | Renton Sunset Community Area Reevaluation and Addendum 11 The 2019 Reevaluation alternative is similar to the 2016 Reevaluation alternative except potential dwelling units would be transferred as follows:  Site C/18 would be reduced from 68 to 25 units and Site E/14,16/17 would be increased from 19 to 62 units. The eastern half of Site C is planned for 12 townhomes in a development currently known as Homestead Willow Crest Townhomes. The development is seeking Self-Help Homeownership Opportunity Program (SHOP) funding. This development has been reviewed in its own NEPA documentation. The reduced number of units allocated to Site C accommodates the 12-unit townhome development on the east. The western portion of Site C has not yet been planned but could accommodate another 13 units with the balance of the 25-unit allocation. The City considered a Comprehensive Plan future land use map change and rezone for Site E in 2018. The Future Land Use Map was changed from Residential High Density to Commercial Mixed Use. The site was also correspondingly rezoned from R-14 to Center Village (CV). The reallocation of the units is consistent with the density allowed by the CV zone. Site E is proposed for affordable attached dwelling units in a development called Sunset Oakes. It is anticipated that units will be rented with project-based vouchers using RHA operating subsidies; there is no direct federal capital funding. The Master Site Plan concept would be retained per Exhibit 1 at this time. In the future, it is possible that Site G/11 will be removed from the Master Site Plan; however, it would still be located in the Sunset Area neighborhood, retain its zoning, and be allowed development similar to that in the Master Site Plan. It may develop with public housing, privately developed housing, mixed uses, or other forms of development allowed by the CV zoning district. The boundary reduction would require a Major Site Plan amendment and PAO amendment if proposed in the future. 2.3 DEVELOPMENT STANDARDS Sites C/18 and E/14,16/17 proposed for unit reallocations are addressed below together with cumulative development allowed in the Master Site Plan area and the Sunset Area neighborhood. Other sites in the study area were addressed in the 2011 EIS and the 2014 and 2016 NEPA/SEPA Reevaluations. 2.3.1 Building Height All sites would be designed to meet allowable heights of their respective zones. Site E/14,16/17 was considered to be developed at three stories in the 2016 Reevaluation and associated Master Site Plan height analysis. While the CV zone allows heights of 50 feet with 10 feet more for retail on the ground floor, the proposed Sunset Oaks development would be 33 feet maximum consistent with the 2016 height analysis; thus, no further height or shade/shadow analysis is needed. Site C/18 was evaluated in the 2016 Master Site Plan with conceptual buildings extending up to 50-60 feet in height consistent with the CV zone. Detailed site plans have been prepared for the eastern portion of the property with three-story townhomes, less than the maximum height of the zone. The western portion of the site is undesigned and subject to the maximum 50-60 feet in height. August 2019 | Renton Sunset Community Area Reevaluation and Addendum 12 2.3.2 Density All sites are consistent with the density requirements of the zoning code or density transfer agreements. Sites D, H, I, and J were allowed to exceed site-specific density in 2014 based on the density transfer from the larger park via the Master Site Plan approval. With detailed development site plans for Sites H and K, the density increased on Site H since the lot is a little smaller than originally projected. However, the 2014 Master Site Plan transferred density from the park to the sites since it was conceptually planned together and part of the original Sunset Terrace public housing site. Density for sites part of original Sunset Terrace (D, H-M) including the Sunset Neighborhood Park is 76.6 units per acre less than the maximum 80 units (7.3 acres and 559 units). See Exhibit 9. Exhibit 9. Density Standards and Results Notes: R-14 zone allows a bonus density: Per 4-9-065 Density Bonus Review: Up to 4 additional dwelling units per net acre. Densities of greater than eighteen (18) units per net acre are prohibited. CV Zone: RMC 4-9-065 allows a bonus of 50% above maximum density in the CV zone. Source: City of Renton Municipal Code; BERK Consulting 2019. 2.3.3 Parking Subject sites will be required to meet City parking standards. The standards for parking are as follows: Attached dwellings in RM-F, R-14, and R-10 Zones: A minimum and maximum of 1.6 per 3 bedroom or large dwelling unit; 1.4 per 2 bedroom dwelling unit; 1.0 per 1 bedroom or studio dwelling unit. In addition to the minimum parking stalls required, a minimum 10% of the total number of required parking spaces shall be provided for guest parking and located in a common area accessible by guests. Attached dwellings within all other zones: 1 per dwelling unit is required. A maximum of 1.75 per dwelling unit is allowed. Attached dwellings for low income: A minimum of 1 for each 4 dwelling units is required [0.25]. A maximum of 1.75 per dwelling unit is allowed. Project Name Total Proposed Units with Reevaluation Density Reevaluation Zone Maximum Density Greater or Lesser than Maximum Density Proposed Building Height in Feet RHA Sunset Terrace- Sunset Area Replacement and Affordable Housing Units C Edmonds Apartments/Homestead Willow Crest 1.70 25 14.7 80.0 (65.3) 60.0 60.00 - D Sunset Terrace Apartments 0.51 47 93.0 80.0 13.0 60.0 50.00 10.0 E Sunset Park West Townhomes 2014 / Harrington Park 2016/ Sunset Oaks 2019 1.05 62 59.2 80.0 (20.8) 33.0 50.00 (17.0) F Sunset Court Townhomes 2014 / Sunset Court 1.95 50 25.6 80.0 (54.4) 39.0 50.00 (11.0) G Sunset Park East (Piha) Townhomes & Apts 2014 / Suncrest Homes 2016 / Solera 2019 1.09 64 58.6 80.0 (21.4) 48.0 50.00 (2.0) Other Sunset Terrace Public and Private Projects - H Sunset Terrace Dev. Building A 0.58 117 202.4 80.0 122.4 68.0 60.00 8.0 I Sunset Terrace Dev. Building B 1.18 196 166.0 80.0 86.0 62.0 50.00 12.0 J Sunset Terrace Dev. Building C 0.74 110 148.3 80.0 68.3 58.0 50.00 8.0 K Renton Highlands Library 0.37 27.0 60.00 (33.0) L Regional Stormwater Facility See park M Sunset Park 3.21 N Sunset Lane Loop Improvements 1.41 O NE 10th Street Extension, Improvements 0.20 Total Sunset Terrace Improvement Projects 13.99 671 48.0 Density Exlcluding Rights of Way 671 52.5 Greater or Lesser Than Maximum Height Property Area per Site Plans Zone Maximum Height August 2019 | Renton Sunset Community Area Reevaluation and Addendum 13 Public housing sites propose parking consistent with the standards for low-income attached dwellings which may range from 0.25 to 1.75 per dwelling unit. 2.3.4 Onsite Open Space In the CV zone, common open space is required to be provided at a rate of fifty (50) square feet per unit. The City may allow substitutions in light of the public park provided adjacent to the properties. See RMC 4-1-240 for Common Open Space Substitutions. This would likely require payment of a Fee-in-Lieu of Common Open Space. This would be addressed in future Site Plan Review applications.  Site C/18 would require 1,250 square feet of onsite open space. The eastern portion of the site with 12 homes proposes 3,886 square feet, which is more than the number for 25 total future units. It is likely the western portion of the site would add to the onsite open space.  Site E/14, 16/17 would require 3,100 square feet of open space. Conceptual site plans show a central tree and mix of hardscape and plantings in the center of the site that would equal at least half of that with other areas of plantings that are beyond the setback areas. Private open space is required to be provided for each dwelling unit. Site plans for site C/18 show townhome units with patio space. Site E plans shows balconies; first floor units appear to have windows/balconies higher than ground level. At the time of Site Plan Review, the Director may approve modifications such as a percentage of units that may have alternative private open space standards if meeting the overall intent of design standards and other criteria at 4-3-100(F) and RMC 4-9-250(D). 2.3.5 Setbacks The CV zone requires a minimum 10-foot setback which may be reduced to 0 feet as part of the site plan development review process, provided blank walls are not located within the reduced setback. Site C/18 on the west facing Edmonds Ave NE has not yet been designed but would be subject to CV zone setbacks. The proposed Sunset Oaks plan for Site E/14,16/17 provides 15 feet setbacks from streets. The northern property line setback includes a 16-foot alley and about 10 feet of plantings or parking access areas. 2.4 FACILITY AND INFRASTRUCTURE PROPOSALS Detailed infrastructure plans will be required to meet City standards for utility hookups, fire flow pressure, and stormwater standards including the conceptual utility plan that was part of the PAO. 2.5 UPDATED LAND COVER / IMPERVIOUS ANALYSIS The FEIS included an analysis of changes in impervious surfaces. Additionally, consistent with the requirements of Section 7 of the Endangered Species Act (ESA), the original 2011 proposal was evaluated with respect to potential effects on species listed or proposed for listing under the ESA. A biological assessment was prepared and submitted to the National Marine Fisheries Service (NMFS) in December 2010 for its concurrence with a finding that the proposal may affect, but is not likely to adversely affect, anadromous fish protected under the ESA, and would have no effect on any ESA-protected species under U.S. Fish and Wildlife Service jurisdiction. The City and NMFS August 2019 | Renton Sunset Community Area Reevaluation and Addendum 14 corresponded in January, February, and April 2011 on NMFS questions. The City received a letter of concurrence in May 2011. Exhibit 10 shows the land cover analysis associated with the 2011 FEIS Alternative 3, and Exhibit 11 shows the analysis associated with the Preferred Alternative; both were addressed in the FEIS, ROD, and NMFS correspondence. Exhibit 10. FEIS Alternative 3 Land Cover Analysis Location Total Area (acres) Total Impervious Area (acres) Total Pervious Area (acres) Total PGIS (acres) Total Untreated PGIS (acres) Effective Impervious (acres) Potential Replacement Sites 3.06 2.28 0.78 0.62 0.26 2.14 Potential Sunset Terrace Redevelopment Subarea 12.64 7.04 6.02 2.43 0 4.22 Total 15.70 9.32 6.80 3.05 0.26 6.36 Notes: PGIS = Pollutant generating impervious surfaces Source: CH2MHill, April 29, 2011, memo to Erika Conkling, City of Renton, Summary of Sunset Terrace Land Coverage Analysis in Response to NMFS Comments Exhibit 11. FEIS Preferred Alternative Land Cover Analysis Location Total Area (acres) Total Impervious Area (acres) Total Pervious Area (acres) Total PGIS (acres) Total Untreated PGIS (acres) Effective Impervious (acres) Potential Replacement Sites 3.06 2.57 0.49 0.41 0 2.39 Potential Sunset Terrace Redevelopment Subarea 12.64 6.1 6.54 1.7 0 3.66 Total 15.70 8.67 7.03 2.11 0 6.15 Notes: PGIS = Pollutant generating impervious surfaces Source: CH2MHill, April 29, 2011, memo to Erika Conkling, City of Renton, Summary of Sunset Terrace Land Coverage Analysis in Response to NMFS Comments The following table shows an updated analysis of the 2019 Reevaluation Proposal, including sites that are amended regarding unit reallocations but also other sites that have been constructed using approved site plans, and sites under planning with updated site plans. Results show the total impervious area, pollutant generating impervious surfaces (PGIS), and effective impervious area is less than FEIS Alternative 3. August 2019 | Renton Sunset Community Area Reevaluation and Addendum 15 Exhibit 12. Reevaluation 2019 Land Cover Analysis Location Total Area (acres) Total Impervious Area (acres) Total Pervious Area (acres) Total PGIS (acres) Total Untreated PGIS (acres) Effective Impervious (acres)* Potential Replacement Sites 4.14 1.38 2.76 0.45 0.26 0.83 Potential Sunset Terrace Redevelopment Subarea 12.69 6.99 5.74 1.64 0 4.19 Total 16.83 8.37 8.50 2.09 0.26 5.02 Notes: PGIS = Pollutant generating impervious surfaces . Sources: Veer, Schemata, Colpitts, City of Renton, Renton Housing Authority, CH2MHill, BERK , 2014; Schemata, Renton Housing Authority, BERK 2015; Third Place Design, Lank Tree Land Surveying, BERK, 2019. Notes: *Per FEIS & BA, assumes that 40% of the impervious area in the site would be mitigated with flow control best management practices. Total acres within the study area as a whole are higher than in 2011 due to properties for replacement housing added in 2016. However, with updated site plan information across the Master Site Plan area, total impervious area is lower due to the proposed designs of the sites many of which have pervious sidewalks and pavement (e.g. Glenwood Townhomes, Sunset Court), lesser Sunset Terrace right-of-way, and the larger park. To keep within impervious limits, the following features are included with sites where units are being reallocated in this 2019 Reevaluation:  Site C/18: Sidewalk dedication is assumed to be pervious due to green street designation of Edmonds Avenue NE as a “green street” in the City’s plans for the Sunset Area.  Site E/14, 16/17: The Sunset Oakes development would include pervious parking and pervious sidewalks, if necessary to meet any impervious requirements and to be consistent with the cumulative impervious range and cap evaluated for the Sunset Area NEPA/SEPA Record of Decision. Therefore, the 2019 Reevaluation Alternative is in the range of the prior analysis and no further analysis or conditions are needed in association with the proposal. The City communicated with NOAA in 2019 and received confirmation that no new formal consultation is needed with regard to the ESA as the results are within the range previously received in the 2011 letter of concurrence. (pers com, Janet Curran, NOAA to Rocale Timmons, City of Renton, October 30, 2015) The analysis updated in 2019 has been submitted to NOAA and is anticipated to receive a similar confirmation of consistency with prior conditions. Should Site G/11 site be removed from the Master Site Plan in the future, the base impervious area would not change as the site is undeveloped. The future impervious area would be reduced within the Master Site Plan area. The site would be subject still to the City’s stormwater regulations. Once removed the total area subject to the impervious surfaces limits would be reconfigured but more similar in land area to the 2011 and 2014 acres. 2.6 PHASING The redevelopment of the study area and broader neighborhood was anticipated to occur over a number of years. The Master Site Plan sites are being phased over an approximate 10-year period August 2019 | Renton Sunset Community Area Reevaluation and Addendum 16 in approximately 5 phases. Phase 1 sites have approved site plans or are in active permit review. Other phases are approximately estimated based on prior Master Site Plan evaluations. See Exhibit 13. Exhibit 13. Site Phasing = Master Site Plan Sites Sources: Veer, Schemata, Colpitts, City of Renton, Renton Housing Authority, BERK 2016 ; BERK, 2019 2.7 MASTER SITE PLAN AND OTHER DISCRETIONARY APPLICATIONS RHA proposes to amend the Master Site Plan per RMC 4-9-200 to reallocate units. For each Master Site Plan site, a number of current and future permits are also anticipated. See Exhibit 14. This Reevaluation and Addendum for the revised proposal will also result in minor revisions of the ROD. Minor housekeeping amendments could be made to the PAO to update information about the 2019 reevaluation though there is no change to total dwellings or PAO mitigation measures. Should Site G/11 be removed from the Master Site Plan in the future, a major Master Site Plan amendment would be needed. In addition, the same conceptual site plan attached to the PAO would be amended. Other development permits and approvals would be required for implementing projects. These could include lot line adjustments/subdivisions, right-of-way dedications and easements, phased/detailed site plans and associated design modifications where appropriate. Lastly, building and construction permits would be sought. Neighbor- hood Site Letter Master Plan Site Phasing RHA Sunset Terrace- Sunset Area Replacement and Affordable Housing Units A Glennwood Townhomes Completed B Kirkland Avenue Townhomes Completed C 18 Edmonds Apartments/Homestead Willow Crest Townhomes Phase 1 Sunset Crest, Phase 4 Edmonds D 5 Sunset Terrace Apartments Phase 5 E 14,16/17 Sunset Park West Townhomes 2014 / Harrington Park 2016/ Sunset Oaks 2019 Phase 1 F 19 Sunset Court Townhomes 2014 / Sunset Court Apartments 2016 Completed G 11 Sunset Park East (Piha) Townhomes & Apts 2014 / Suncrest Homes 2016 / Solera 2019 Phase 1 Other Sunset Terrace Public and Private Projects H 9 Sunset Terrace Dev. Building A Phase 1 I 7/8 Sunset Terrace Dev. Building B Phase 2 J 6/7 Sunset Terrace Dev. Building C Phase 3 K 10 Renton Highlands Library Completed L Regional Stormwater Facility Completed M Sunset Park Completed N Sunset Lane Loop Improvements Extended with Utilities O NE 10th Street Extension, Improvements Extended with Utilities X Library Site Phase 5 August 2019 | Renton Sunset Community Area Reevaluation and Addendum 17 Exhibit 14. Matrix of Permits = Sites permitted/constructed. Sources: Veer, Schemata, Colpitts, City of Renton, Renton Housing Authority, BERK 2016 , BERK 2019. Neighbor- hood Site Letter Master Plan Site Project Name Master PlanHeight CUPDensity InterpretationParking Rate InterpretationStreet Reclass-ificationsNEPA/SEPA ReevaluationROD/Planned Action AmendmentLot Line Adjustment or SubdivisionROW Dedication / EasementsSite Plan ReviewDensity BonusMod: Open SpaceMod: TransparencyMod: Blank WallMod: ModulationBuilding & Construction PermitsRHA Sunset Terrace- Sunset Area Replacement and Affordable Housing Units C 18 Edmonds Apartments/Homestead Willow Crest Townhomes X X X X X D 5 Sunset Terrace Apartments X X X X X X X X E 14, 16/17 Sunset Park West Townhomes 2014 / Harrington Park 2016/ Sunset Oaks 2019 X X X X X X X F 19 Sunset Court Townhomes 2014 / Sunset Court Apartments 2016 G 11 Sunset Park East (Piha) Townhomes & Apts 2014 / Suncrest Homes 2016 / Solera 2019 Other Sunset Terrace Public and Private Projects H 9 Sunset Terrace Dev. Building A X X X X X X X X X X X I 7/8 Sunset Terrace Dev. Building B X X X X X X X X X X X X J 6/7 Sunset Terrace Dev. Building C X X X X X X X X X X X X K Renton Highlands Library L Regional Stormwater Facility M Sunset Park N Sunset Lane Loop Improvements O NE 10th Street Extension, Improvements Approvals and Permits Summer 2014 Future Permits Permits with Site Plan Review August 2019 | Renton Sunset Community Area Reevaluation and Addendum 18 3 Environmental Analysis The analysis of each element of the environment below compares the conclusions from the FEIS regarding Alternative 3 and the Preferred Alternative to the 2019 Reevaluation Alternative. It concludes that the revised Master Site Plan would not change results of the impact analysis or mitigation measures in the FEIS. 3.1 LAND USE The Land Use analysis in the FEIS concluded that the Sunset Area subarea would advance the purposes of the Comprehensive Plan and Center Village (CV) zoning district. It would serve as an incentive for other redevelopment opportunities near the study area. Anticipated growth would also help the City meet its 2031 (now 2035) housing and employment targets. These conclusions are still valid for the 2019 Reevaluation Alternative which proposes housing and mixed uses consistent with zoning and developed in coordination with the Master Site Plan. 3.2 AESTHETICS As described in Section 2.2, the Reevaluation Alternative will reallocate dwelling units among sites, but all sites will meet zoning densities, building heights and setbacks, open space, and landscaping per the code or per the Master Site Plan approval in 2014. Design standards will apply. 3.3 CULTURAL RESOURCES The Master Site Plan area was evaluated for cultural resources in the 2011 EIS and again with the Master Site Plan expansion in 2016. No sites were determined eligible. The ROD includes inadvertent discovery conditions applicable throughout the study area. 3.4 TRANSPORTATION Based on the results of the 2019 Reevaluation traffic analysis, overall transportation conditions are expected to operate similarly to the FEIS Preferred Alternative, Alternative 3, and the 2014 Reevaluation Alternative. The 2019 evaluation includes the Sunset Court site added in 2016. See Appendix A. 3.5 PARKS AND RECREATION The Sunset Neighborhood Park has been constructed in accordance with the adopted Master Site Plan. There are no changes to the FEIS results or prior Reevaluations in 2014 or 2016. 3.6 PUBLIC SERVICES The overall conclusions of the FEIS for Selected Alternatives is expected to be similar for the Reevaluation Alternative since growth is the same as projected for the overall neighborhood and is similar to the 2014 and 2016 Reevaluation proposal. 3.7 UTILITIES 3.7.1 Water and Sewer Conceptual utility plans in the FEIS, City design manuals, and code requirements will apply to future development. August 2019 | Renton Sunset Community Area Reevaluation and Addendum 19 3.8 OTHER FEIS TOPICS Generally, regarding natural environment topics (earth, air quality, water resources, plants and animals), there are no anticipated changes to the overall conclusions or mitigation measures identified in the ROD and PAO since the proposed mixed use development activities are essentially occurring within the same footprint and the range of impervious estimates in the FEIS and ROD will be maintained. Conditions, mitigation measures, and conclusions regarding Environmental Health and Historic/Cultural Features are likewise unchanged. No environmental health conditions or cultural resources features are known in the Potential Sunset Terrace Redevelopment Subarea, but in case such features are uncovered mitigation measures would apply. Lastly, regarding socio-economics, housing, and environmental justice, overall conditions and impacts regarding the potential for change in the neighborhood, need for replacement housing or vouchers, etc. identified in the FEIS are still valid, as the study area continues to redevelop to a mixed use, amenity-rich environment. 3.9 MONITORING AND REVIEW The PAO includes monitoring and review measures to be considered within five years of the ordinance adoption; some measures are to be considered at the time of a NEPA Reevaluation (compliance with neighborhood goals and Leadership in Environmental and Energy Design rating system for Neighborhood Development [LEED-ND] criteria or equivalent), though monitoring and review are directed to the Planned Action area as a whole. The City conducted a review in the 2014 Reevaluation and 2016 Reevaluation. The next 5-year milestone, based on the effective date of the amended ordinance in 2016, would occur in 2021. Consistent with the PAO monitoring provisions, this Reevaluation provides a review of the Planned Action Study Area Goals and Objectives and to the LEED-ND criteria in relation to the Reevaluation Alternative. See Exhibit 15 and Exhibit 16. Results show the 2019 Reevaluation Alternative continues to create a mixed use, mixed income neighborhood supported by park, library, road, and stormwater improvements that increase quality of life. Exhibit 15. Goals and Objectives Reevaluation FEIS Goals and Objectives Reevaluation Alternative: Potential Sunset Terrace Redevelopment Subarea Transformation of private and public properties in the Planned Action Study Area …is expected to meet the Sunset Area Community vision, as expressed in the Highlands Phase II Task Force Recommendations (City of Renton 2008a) and the CIS (City of Renton 2009b). The Highlands is a destination for the rest of the city and beyond. The neighbors and businesses here are engaged and involved in the community. Neighborhood places are interconnected and walkable. The neighborhood feels safe and secure. The Reevaluation Alternative is based on the prior studied alternatives and continues to promote a mixed-income, mixed-use development with parks, library, and green streets to promote an affordable, connected, walkable, and attractive area for residents and businesses. Since the approval of the Planned Action and implementing Master Site Plan, affordable housing has been developed at Sunset Court. Neighborhood civic facilities have been built including the library. The City has developed a more walkable place with streets and streetscapes improved consistent with the Master Site Plan. The Sunset Neighborhood Park has been completed. August 2019 | Renton Sunset Community Area Reevaluation and Addendum 20 FEIS Goals and Objectives Reevaluation Alternative: Potential Sunset Terrace Redevelopment Subarea Neighborhood growth and development is managed in a way that preserves quality of life. The neighborhood is an attractive place to live and conduct business. The neighborhood is affordable to many incomes. The neighborhood celebrates cultural and ethnic diversity. For each of the major components of the proposal, the following specific goals and objectives were developed to be consistent with this vision. The entire Renton Sunset neighborhood is considered a planned action area since 2011 per Exhibit 2; growth and general types of land uses are consistent with the City’s Comprehensive Plan. The PAO, effective in 2011 and amended in 2014 and 2016, remains in effect. The City may update the PAO with the amended 2019 Master Site Plan results. The Reevaluation/Addendum demonstrates that the Planned Action EIS conclusions remain valid. City infrastructure investments for the planned action area continue. For example, regional stormwater and green streets have bene implemented and are expected to continue to be implemented in the neighborhood. A loop road has been implemented; the Library site has been developed. The park was enlarged and has been constructed. 1. Through designation of a Planned Action and infrastructure investments, support and stimulate public and private development. 2. Ensure that redevelopment is planned to conform to the City’s Comprehensive Plan. The Reevaluation Alternative implements the City’s Comprehensive Plan Commercial Mixed-Use designation and furthers the intent of the CV zone for a mixed-use center, providing housing, civic, retail, and park uses. 3. Through the Planned Action and early environmental review, accelerate the transformation of the Potential Sunset Terrace Redevelopment Subarea with mixed-income housing and mixed uses together with places for community gathering. This will also be accomplished in part by using this EIS to achieve a NEPA Record of Decision, which will enable RHA to submit a HUD Demolition and Disposition application in 2015. See Response to #1. A Demolition and Disposition permit was obtained for the Library site and a second permit was obtained for the balance of the site. 4. Ensure that the Planned Action covers environmental review of Sunset Area roadway, drainage, parks and recreation, and other infrastructure improvements, and analyze impacts of anticipated private development in addition to Sunset Terrace. See Response to #1. The total amount of growth studied across the Planned Action study area remains unchanged under the 2019 Reevaluation Alternative; redistribution of some units was evaluated in 2014, 2016, and 2019. Both public and private development is promoted in the Potential Sunset Terrace Redevelopment Subarea as well as the broader neighborhood. August 2019 | Renton Sunset Community Area Reevaluation and Addendum 21 FEIS Goals and Objectives Reevaluation Alternative: Potential Sunset Terrace Redevelopment Subarea 5. Build on previous City, RHA, and Renton School District efforts and current projects. Leverage relationships and partner with existing community outreach activities and resources. Recognize community desires documented in: Report and Recommendation of the Highlands Area Citizen’s Zoning Task Force (City of Renton 2006), Report and Recommendation of the Highlands Phase II Task Force (City of Renton 2008a), Highlands Action Plan (City of Renton 2009c), Sunset Area Community Investment Strategy (City of Renton 2009b), Renton Trails and Bicycle Master Site Plan (City of Renton 2009d), Renton Parks, Recreation, Open Space and Natural Resources Plan (estimated completion date September 2011), Utility system plans, and Library replacement (in process). The Reevaluation Alternative continues to further the prior planning efforts. The following has been developed: Replacement affordable housing at Sunset Court A new library A new larger neighborhood park A regional stormwater facility Harrington Avenue NE Greenstreet Sunset Lane improvements Early childhood education center has been redeveloped The subarea will have additional mixed income, mixed use development as anticipated in the Community Investment Strategy. 6. Create a Great Street on NE Sunset Boulevard, as described in the CIS. Implement the City Complete Streets policy for the NE Sunset Boulevard corridor and the Sunset Area green connections. Extend conceptual design of improvements between the Interstate 405 limited access right-of-way and Monroe Avenue NE and include them in the Planned Action effort. The Reevaluation Alternative Master Site Plan concept anticipates and recognizes the multimodal design of NE Sunset Boulevard by matching the future right of way boundary studied in the FEIS. 7. Encourage low-impact stormwater management methods and area-wide solutions as part of a master drainage plan to support development. The Reevaluation Alternative would be developed consistent with the Sunset Area drainage plan. Regional stormwater in the central park and green streets (e.g. Harrington Avenue NE) have been accomplished with more green infrastructure planned in future phases. 8. Engage the community in a transparent process using available outreach opportunities and tools successfully used in prior planning efforts. The Reevaluation Alternative is similar to prior studied alternatives that were developed with public engagement opportunities. Public comment opportunities are offered with some types of land use permits (e.g. Notices of Application), or amendments to the PAO. 9. Optimize funding strategies by leveraging partnerships, innovation and sustainable development for a healthy community. Recognize the importance and timing of integrating housing, transportation, infrastructure, expanded economic The Reevaluation Alternative has resulted from a public/private Master Site Plan coordination effort. See response to #1 regarding infrastructure and civic investments. August 2019 | Renton Sunset Community Area Reevaluation and Addendum 22 FEIS Goals and Objectives Reevaluation Alternative: Potential Sunset Terrace Redevelopment Subarea opportunity, parks and recreation, and the environment. Source: FEIS, Appendix A, 2011; BERK 2014 The official 2014 LEED ND project scorecard3 published by the U.S. Green Building Council is used as a guide to address green design issues in relation to the proposed redevelopment. For each criteria group on the scorecard, a brief discussion of how the proposed redevelopment is consistent with the principles of LEED ND is provided in Exhibit 16. Exhibit 16. LEED for Neighborhood Development Criteria Summary of Criteria Reevaluation Alternative: Potential Sunset Terrace Redevelopment Subarea The intent of the Smart Location and Linkage criteria of the LEED ND rating system is to encourage development to avoid environmentally sensitive areas and to be focused within and near existing communities where there are opportunities to access services and reach destinations. There is a preference for housing proximate to jobs. Access to public transit is promoted to reduce vehicle trips. Development in smart locations also encourages a greater degree of walking of bicycling, which has personal health benefits. The Sunset Terrace site is located along a major transportation and transit corridor within the City of Renton. Redevelopment of the site under the Reevaluation Alternative would contribute to a mixed-use, mixed-income development already served by the full range of public services on a previously developed infill site on a major transit corridor – a “smart location.” The Master Site Plan concept anticipates and recognizes the multimodal design of NE Sunset Boulevard by matching the future right of way boundary studied in the FEIS. The intent of the Neighborhood Pattern and Design criteria of the LEED ND rating system is to promote safe, diverse, walkable, compact neighborhoods with high-quality design with a mix of land uses. The Master Site Plan furthers the intent of the Comprehensive Plan Mixed Use Commercial designation and CV zone for a mixed-use center, providing housing, civic, retail, and park uses. The neighborhood is compact and furthers walkability and quality design with a loop road, green streets, and a new park and library. The intent of the Green Infrastructure and Buildings criteria is to encourage development that implements green building practices or introduces green infrastructure. This includes using certified green building techniques, increasing building water and energy efficiency, controlling pollution from construction activities, implementing adaptive reuse of historic buildings, and using green methods of stormwater management. The Reevaluation Alternative as expressed in the amended Master Site Plan would implement FEIS mitigation measures and retain green features of prior studied alternatives, including: Green Connections for Stormwater Management: The Reevaluation Alternative continues the City’s investment in Green Connections (Harrington Avenue NE implemented), a regional stormwater facility (built), and the drainage Master Site Plan for the study area. Construction Emission Control: The FEIS recommends that the City require all construction contractors to implement air quality control plans 3 See: Checklist: LEED v4 for Neighborhood Development. https://www.usgbc.org/resources/leed-v4-neighborhood- development-checklist. Accessed: July 22, 2019. August 2019 | Renton Sunset Community Area Reevaluation and Addendum 23 Summary of Criteria Reevaluation Alternative: Potential Sunset Terrace Redevelopment Subarea for construction activities in the study area, including measures for reducing engine emissions and fugitive dust. Energy Efficiency: The FEIS recommends that the City encourage or require implementation of energy and greenhouse gas reduction measures in the study area such as compliance with the Northwest ENERGY STAR Homes program and the Seattle Energy Code for non-residential buildings. Source: FEIS, Appendix A, 2011; BERK, 2014 and 2019. 4 Conclusions The City of Renton (City) is the Responsible Entity and lead agency for NEPA purposes. In accordance with specific statutory authority and the U.S. Department of Housing and Urban Development’s (HUD’s) regulations at 24 Code of Federal Regulations (CFR) part 58, the City is authorized to assume responsibility for environmental review, decision-making, and action that would otherwise apply to HUD under NEPA. Additionally, the City is the lead agency and proponent of the broader Planned Action for the Sunset area which has had environmental review under Washington State Environmental Policy Act (SEPA) Revised Code of Washington [RCW] 43.21(C). The City has performed joint NEPA/SEPA environmental review in cooperation with the Recipient, the Renton Housing Authority (RHA). Accordingly, the City prepared a Draft and Final EIS to analyze potential impacts of redevelopment of the Sunset Terrace public housing community. The Final Environmental Impact Statement (FEIS) supporting both milestones was issued April 1, 2011. The City initiated consultation with agencies and tribes regarding permit requirements and to identify any areas of concerns regarding the Sunset Terrace public housing redevelopment as well as the overall Planned Action. Federal and state agencies were notified of comment opportunities through the scoping process and were offered comment opportunity on the Draft EIS. Two agencies were particularly consulted consistent with NEPA, the National Historic Preservation Act (Section 106), and the Endangered Species Act (Section 7). As documented in the ROD and Environmental Review Record, the City received a letter of concurrence from NMFS in May 2011. The Biological Assessment and NMFS memoranda are included in the Environmental Review Record. The City also completed Section 106 consultation for Sunset Terrace redevelopment and all properties fronting NE Sunset Boulevard as documented in the ROD and Environmental Review Record. In addition, consistent with the federal Coastal Zone Management Act, the City received a letter of consistency from the State of Washington Department of Ecology (16 U.S.C. 1451- 1464). In May 2011, the City of Renton completed a ROD in accordance with the National Environmental Policy Act and adopted a PAO in accordance with the State Environmental Policy Act. The ROD and PAO identified mitigation measures from the FEIS. The Record of Decision (ROD) concluded that “[w]ith the application of City-adopted development regulations and recommended mitigation measures, and application of other federal and state requirements, no significant unavoidable adverse impacts are anticipated. Pursuant to 40 CFR 1505.3, this decision to proceed with Sunset Terrace and actions in the broader area will be implemented and mitigation measures imposed through appropriate conditions in any land use or related permits or approvals issued by the City of Renton and through conditions of federal funding.”This Reevaluation and Addendum maintains the mitigation measures from the EIS,ROD,and Planned Action and identifies where the application of such mitigation measures (e.g., design guidelines)is particularly relevant and could be included in permit conditions. The City finds by this re-evaluation,after considering the effects of the revised Master Site Plan,as well as existing and supplemental environmental documentation,that no substantive change to the findings in the ROD would occur.The Sunset Area Community Planned Action NEPA/SEPA EIS adequately examines the impacts of the overall prolect,and the proposed changes in the Master Site Plan would not result in modification to those conclusions.No new or significantly different impacts to the environment would occur. Mitigation measures incorporated in the proposal and identified in the EIS,and additional consultation and mitigation documented in the ROD,represent reasonable steps to reduce adverse environmental effects of the proposed prolect.Together,these measures and would reduce effects to acceptable levels,No additional mitigation is warranted as a result of changes proposed in the Master Site Plan. Responsible Entity Certifying Officer City of Renton Environmental Review Committee (ERC) Date:qq/i Signature:_____________________ _z,f- Signature:. Signature: August 201 9 I Renfon Sunset Community Area Reevaluation and Addendum I 24 1 Renton Sunset Terrace Impervious Surfaces Analysis August 2019 | Prepared By: BERK Consulting Environmental Review 2011 In May 2011, the City of Renton completed a Record of Decision (ROD) in accordance with the National Environmental Policy Act (NEPA) and adopted a Planned Action Ordinance in accordance with the State Environmental Policy Act (SEPA) for redevelopment of the Sunset Terrace area. The NEPA/SEPA Final Environmental Impact Statement (FEIS)1 supporting both milestones was issued April 1, 2011. The ROD and Planned Action established a range of growth and associated facility and infrastructure investments (e.g. park, library, “green streets,” etc.) for the Sunset Area Community Planned Action Study Area, for the neighborhood as a whole and for the Sunset Terrace Redevelopment, a site then fully owned by the Renton Housing Authority (RHA). In support of the NEPA/SEPA process, an analysis of change in impervious surfaces was addressed in the FEIS. Additionally, consistent with the requirements of Section 7 of the Endangered Species Act (ESA), the proposal has been evaluated with respect to its potential effects on species listed or proposed for listing under the ESA. A biological assessment was prepared and submitted to the National Marine Fisheries Service (NMFS) in December 2010 for its concurrence with a finding that the proposal may affect, but is not likely to adversely affect, anadromous fish protected under the ESA, and would have no effect on any ESA-protected species under U.S. Fish and Wildlife Service jurisdiction. The City and NMFS corresponded in January, February, and April 2011 on NMFS questions. The City received a letter of concurrence in May 2011. Study Area The Study Area that was the focus of the NMFS consultation included sites in the Potential Sunset Redevelopment Study Area (shaded in purple) and swap sites (outlined in red) shown in Exhibit 1. Since the original 2011 analysis more specific Master Planning has been conducted for the Potential Sunset Redevelopment Study Area and some abutting property added to facilitate master planning. See Exhibit 2 and Exhibit 3. 1 CH2MHill and ICF International. 2011. Sunset Area Community Planned Action NEPA/SEPA Environmental Impact Statement. Final. April. (ICF 00593.10.) Bellevue and Seattle, WA. Prepared for City of Renton and the Renton Housing Authority, Renton, WA. August 2019 | Renton Sunset Terrace Impervious Surfaces Analysis 2 Exhibit 1. Renton Sunset Terrace Redevelopment Area and Swap Sites: 2011 August 2019 | Renton Sunset Terrace Impervious Surfaces Analysis 3 Exhibit 2. Renton Sunset Terrace Redevelopment Area and Swap Sites: 2016 and 2019 August 2019 | Renton Sunset Terrace Impervious Surfaces Analysis 4 Exhibit 3. Sunset Terrace Master Site Plan Activities and Review: 2014-2016 Since May 2011, redevelopment efforts have continued, including the Demolition and Disposition permit for a Mixed Use Library redevelopment on a portion of the property and a purchase and sale agreement with a private developer. This has been followed by a Demolition and Disposition permit for the balance of the Sunset Terrace property allowing for both market rate and affordable dwellings. RHA has developed plans or has constructed units in the Sunset Area that could serve as replacement units for Sunset Terrace when redeveloped. There would be no net loss of affordable units. As a result of ongoing planning for the area, the City approved additional dwellings and height in the Sunset Terrace area in 2014. The City prepared a revised Master Plan including a new Conceptual Plan to be developed and approved under the Renton Municipal Code (RMC) Title IV. This Master Plan is intended to facilitate the preparation of phased detailed Site Plans over time and would allow the City to determine consistency with applicable regulations. This will also provide more certainty for members of the public and private developers. 2014 Reevaluation: The changes to the development proposal to add more units and height and to address street standards also required a NEPA Reevaluation, pursuant to Section 58.47 of US Department of Housing and Urban Development’s (HUD’s) NEPA regulations, demonstrating that the original conclusions of the FEIS remain valid. SEPA also provides a process, using an Addendum to the prior FEIS where new information or analysis does not substantially change prior conclusions about impacts (WAC 197-11-706). August 2019 | Renton Sunset Terrace Impervious Surfaces Analysis 5 On September 15, 2014, NOAA acknowledged the 2014 reevaluation proposal was within the range of effects considered in the previous analysis, and there was no need to re-initiate consultation. (Curran, NOAA, pers com) 2015-2016 Reevaluation: The City and RHA added replacement housing for the Sunset Terrace redevelopment on properties abutting the master plan. See Exhibit 2 and Exhibit 3. This required a NEPA Reevaluation pursuant to the same process described above for the 2014 proposal. In fall 2015, NOAA found the revised design is within the scope and range of effects considered in the Endangered Species Act consultation for the project (NMFS 2010/01983). The City and RHA completed the Reevaluation in 2016. Reevaluation Alternative 2019 In 2019, RHA is proposing an amended Master Plan that would shift dwelling units between a site on the west (Site 18) to a site in the north of the Master Plan area (Site 14, 16/17). This 2019 reevaluation also assesses the future removal of a site from the master plan boundaries (Site 11). The site would remain within the Sunset Area Community neighborhood and zoning and development allowed is similar. This Master Plan boundary amendment proposal is evaluated for potential implementation at a later date. The purpose of this document is to document how the 2019 reevaluation proposal is in the range of the prior analysis of impervious areas contained in the FEIS, ROD and NMFS consultation process. In 2019, the City has rearranged allowed dwellings between sites 18 and 14/16/17 but the total units would remain the same over the study area. See Exhibit 3. August 2019 | Renton Sunset Terrace Impervious Surfaces Analysis 6 Exhibit 3. Master Plan Sites – Reevaluation 2014, 2016, 2019 Impervious Analysis Exhibit 4 shows the land cover analysis associated with FEIS Alternative 3, and Exhibit 5 shows the analysis associated with the Preferred Alternative, both addressed in the FEIS, ROD and NMFS correspondence. Exhibit 4. FEIS Alternative 3 Land Cover Analysis Location Total Area (acres) Total Impervious Area (acres) Total Pervious Area (acres) Total PGIS (acres) Total Untreated PGIS (acres) Effective Impervious (acres) Potential Replacement Sites 3.06 2.28 0.78 0.62 0.26 2.14 Potential Sunset Terrace Redevelopment Subarea 12.64 7.04 6.02 2.43 0 4.22 Total 15.70 9.32 6.80 3.05 0.26 6.36 Source: CH2MHill, April 29, 2011, memo to Erika Conkling, City of Renton, Summary of Sunset Terrace Land Coverage Analysis in Response to NMFS Comments Master Plan Site Development Title Acres: 2014 Total Units Reviewed in Reevaluation: 2014 Acres: 2016 Total Units Reviewed in Reevaluation: 2016 Acres: 2019 Total Units Reviewed in Reevaluation: 2019 Glennwood Townhomes 0.65 8 0.65 8 0.65 8 Kirkland Avenue Townhomes 0.77 18 0.77 18 0.77 18 18 Edmonds Apartments/Sunset Crest 1.70 112 1.70 68 1.70 25 5 Sunset Terrace Apartments 0.51 54 0.51 47 0.51 47 14, 16/17 Sunset Park West Townhomes 2014 / Harrington Park 2016/ Sunset Oaks 2019 0.55 10 1.06 19 1.05 62 19 Sunset Court Townhomes 2014 / Sunset Court Apartments 2016 0.88 15 1.95 50 1.95 50 11 Sunset Park East (Piha) Townhomes & Apts 2014 / Suncrest Homes 2016 / Solera 2019 1.09 57 1.09 64 1.09 64 9 Sunset Terrace Dev. Building A 0.99 117 0.99 117 0.58 117 7/8 Sunset Terrace Dev. Building B 1.18 196 1.18 196 1.18 196 6/7 Sunset Terrace Dev. Building C 0.74 110 0.74 110 0.74 110 10 Renton Highlands Library See H See H 0.37 Regional Stormwater Facility See M See M See M Sunset Park 3.20 3.2 3.2 Sunset Lane Loop Improvements 1.41 1.41 1.41 NE 10th Street Extension Improvements 0.20 0.20 0.20 Library Site (2013)1.41 25 1.41 25 1.41 25 Total - Master Plan Sites 12.44 671 14.04 671 13.99 671 Total - All Sites 15.28 722 16.88 722 16.83 722 August 2019 | Renton Sunset Terrace Impervious Surfaces Analysis 7 Exhibit 5. FEIS Preferred Alternative Land Cover Analysis Location Total Area (acres) Total Impervious Area (acres) Total Pervious Area (acres) Total PGIS (acres) Total Untreated PGIS (acres) Effective Impervious (acres) Potential Replacement Sites 3.06 2.57 0.49 0.41 0 2.39 Potential Sunset Terrace Redevelopment Subarea 12.64 6.1 6.54 1.7 0 3.66 Total 15.70 8.67 7.03 2.11 0 6.15 Source: CH2MHill, April 29, 2011, memo to Erika Conkling, City of Renton, Summary of Sunset Terrace Land Coverage Analysis in Response to NMFS Comments The following table shows an updated analysis of the 2019 Reevaluation Proposal, including sites that are amended regarding unit reallocations but also other sites that have been constructed using approved site plans, and sites under planning with updated site plans. Results show the total impervious area, pollutant generating impervious surfaces (PGIS), and effective impervious area is less than FEIS Alternative 3. Exhibit 6. Reevaluation 2019 Land Cover Analysis Location Total Area (acres) Total Impervious Area (acres) Total Pervious Area (acres) Total PGIS (acres) Total Untreated PGIS (acres) Effective Impervious (acres)* Potential Replacement Sites 4.14 1.38 2.76 0.45 0.26 0.83 Potential Sunset Terrace Redevelopment Subarea 12.69 6.99 5.74 1.64 0 4.19 Total 16.83 8.37 8.50 2.09 0.26 5.02 Notes: PGIS = Pollutant generating impervious surfaces. Sources: Veer, Schemata, Colpitts, City of Renton, Renton Housing Authority, CH2MHill, BERK, 2014; Schemata, Renton Housing Authority, BERK 2015; Third Place Design, Lank Tree Land Surveying, BERK, 2019. Notes: *Per FEIS & BA, assumes that 40% of the impervious area in the site would be mitigated with flow control best management practices. Consistent with the 2016 Reevaluation, total acres within the study area as a whole are higher due to the added properties for replacement housing. However, with updated site plan information across the Master Plan area, total impervious area is lower due to the proposed designs of the sites where some have pervious sidewalks and pavement (e.g. Glenwood Townhomes, Sunset Court), lesser Sunset Terrace right-of-way, and the larger park. RHA has also indicated use of pervious parking and sidewalks for proposed development not yet constructed, if necessary to meet any impervious requirements and to be consistent with the cumulative impervious range and cap evaluated for the Sunset Area NEPA/SEPA Record of Decision. Under the 2019 Reevaluation alternative, PGIS and effective impervious area are a little lower overall than Alternative 3. Therefore, the Reevaluation Alternative 2019 is in the range of the prior analysis and no further analysis or conditions are needed in association with the proposal. Should Site 11 be removed from the Master Plan in the future, the base impervious area would not change as the site is undeveloped. The future impervious area would be reduced within the Master Plan area. The August 2019 | Renton Sunset Terrace Impervious Surfaces Analysis 8 site would be subject still to the City’s stormwater regulations. Once removed the total area subject to the impervious surfaces limits would be reconfigured though similar to total acres evaluated in the 2011 EIS. 12131 113th Avenue NE, Suite 203, Kirkland, WA 98034 | 425.821.3665 | MEMORANDUM Date: July 23, 2019 TG:1.19223.00 To: Lisa Grueter, AICP – BERK From: Brent Turley, PE – Transpo Group Subject: Sunset Oaks and Master Site Plan: Transportation Analysis The purpose of this Transportation Analysis memorandum is to provide NEPA/SEPA documentation for the Master Site Plan changes based on a review of traffic volume changes and comparisons to previous studies. The Renton Travel Demand Model was reviewed as part of this analysis, but the land use changes fall within only one transportation analysis zone (TAZ) and would have a net zero land use change in that zone. Rather than use the travel demand model, the traffic analysis approach focused on the net change in intersection trips at major locations around the Master Plan Site. These were then compared to the intersection analysis results found in the Sunset Area Community Planned Action Update: Traffic Analysis Results - May 2014 Redevelopment Master Site Plan Alternative documentation. Project Description The proposed land use changes would shift residential units between several parts of the area while maintaining the same overall total number of units. Table 1 summarizes the proposed changes by Master Plan sites. For reference, the site locations are shown in Figure 1. Table 1 is separated into two sections based on how trips from each site accesses Renton’s arterial and collector street network. Site #18 generally uses Edmonds Avenue NE to access the network. The remaining sites use Harrington Avenue NE or NE 10th Street. The changes in land use show that 87 residential units shift from Site #18 to the other sites. In other words, intersections along Edmonds Avenue NE would see a reduction in trips, while Harrington Avenue NE and NE 10th Street would see an increase in trips. This analysis focuses on the impacts on study intersections on Harrington Avenue NE and NE 10th Street due to an 87-unit increase. Table 1. Master Plan Land Use Changes Townhomes/Apartment Units Neighborhood Site ID Master Plan Site Development 2014 2019 Change Neighborhood Access via Edmonds Ave C 18 Edmonds Apartments 112 25 -87 Neighborhood Access via Harrington Ave or 10th St D 5 Sunset Terrace Apartments 54 47 -7 E 14, 16/17 Sunset Oaks 2019 10 62 +52 F 19 Sunset Court 2016 15 50 +35 G 11 Solera 2019 57 64 +7 Subtotal 136 223 +87 Total 248 248 +0 Source: BERK, 2019 2 Figure 1 – Master Plan Area Trip Generation Trip generation for the net change in shifted units was estimated based on the Land Use #220 (Multifamily Housing (Low-Rise)) average trip rates from Trip Generation, 10th Edition, Institute of Transportation Engineers (ITE), 2017. Weekday daily and AM and PM peak hour trip generation estimates are summarized in Table 2 and include inbound and outbound daily and peak hour estimates. Table 2. Estimated Weekday Trip Generation Project Trips Land Use Size Rate1 Total In Out Multifamily Housing (Low-Rise) LU #220 87 du Weekday Daily 7.32 636 318 318 Weekday AM Peak Hour 0.46 40 9 31 Weekday PM Peak Hour 0.56 49 31 18 Note: du = dwelling units 1. Trips rates from ITE Trip Generation Manual, 10th Edition (2017). 3 As shown in Table 1, it is estimated that 87 new lowrise units would generate approximately 636 vehicle trips over the course of a typical weekday including 40 trips during the weekday AM peak hour and 49 trips during the weekday PM peak hour. Trip Distribution and Percent Impact The trips generated were distributed to major intersections along Harrington Avenue NE and NE 10th Street near the site. The trip distribution is based on the Sunset Court TIA (Perteet, 2015) which has very similar characteristics. As Table 3 shows, approximately 30 percent of project trips would be oriented to the north at the NE 12th Street/Harrington Avenue NE intersection. About 45 percent would be oriented southeast to the NE Sunset Boulevard/NE 10th Street intersection. Another 25 percent would be oriented southwest to the NE Sunset Boulevard/Harrington Avenue NE intersection. Other major intersections would be expected to have very little net new trips. Table 3 summarizes the amount of net new trips expected at these intersections and how they relate to overall intersection traffic volumes. Between 12 to 22 net new trips are expected. For NE Sunset Boulevard intersections, the net new trips would represent less than one percent of 2015 traffic volumes. For the NE 12th Street/Harrington Avenue NE intersection, the net new trips would represent about 2.4 percent. To keep this analysis conservative, trip reductions to/from Site #18 were assumed to be zero for east-west through volumes at the study intersections. Table 3. Trip Distribution and Percent Impact Intersection Trip Distribution1 New PM Peak Hour Shifted Trips2 2015 Total Entering Volumes (TEV)1 New Shifted Trips as Percent of TEV NE 12th St/Harrington Ave NE 30% 15 620 2.4% NE Sunset Blvd/NE 10th St 45% 22 2,350 0.9% NE Sunset Blvd/Harrington Ave NE 25% 12 2,326 0.5% Source: Transpo Group 1. Trip distribution and traffic counts based on Sunset Court TIA, Perteet, 2015 2. There may be some east-west through trips on NE Sunset Blvd and NE 12th Street that may be removed due to shifts, but this analysis conservatively assumed these trips were zero. Traffic Analysis Results The previous Master Site Plan 2030 level of service (LOS) analysis at these three study intersections are documented in the Sunset Area Community Planned Action Update: Traffic Analysis Results - May 2014 Redevelopment Master Site Plan Alternative (CH2MHill, 2014). The NE Sunset Boulevard intersections were shown to be LOS C or better. The NE 12th Street/Harrington Avenue NE was shown to be LOS F in the previous Master Site Plan 2030 analysis. As shown in Table 3, the net new traffic at study intersections were between 12 and 22 trips and represent between 0.5 and 2.4 percent of total intersection volumes for 2015 conditions and would be even less for 2030 conditions. The relatively minor net new trips at the study intersection would not significantly change the LOS or delays at these intersections from the previous 2030 analysis. DEPARTMENTOFCOMMUNITYANDECONOMICDEVELOPMENT—RentonADMINISTRATIVESITEDEVELOPMENTPLANREPORT&DECISIONREPORTDATE:June20,2016ProjectName:RentonSunsetTerraceRedevelopment(2016Modification)Owner/Applicant:CityofRenton;RentonHousingAuthority;SunsetTerraceDevelopmentLLCFileNumber:LUA14-001475,MODProjectManager:RocaleTimmons,SeniorPlannerProjectSummary:TheapplicantisrequestingaMinorSitePlanModificationforamendmentstotheapprovedSunsetPlannedActionAreaandRentonSunsetTerraceRedevelopmentMasterSitePlan(LUA1O-052andLUA14-001475)inordertoincludeanadditionalfiveparcelsandtoswapresidentialunitsbetweentwomasterplannedsites.Noadditionalresidentialunitsarebeingproposed.TherevisedproposalrequiresaNEPAReevaluation,pursuanttoSection58.47ofUSDepartmentofHousingandUrbanDevelopment’s(HUD’s)NEPAregulations,demonstratingthattheoriginalconclusionsoftheFEISremainvalid.SEPAalsoprovidesaprocess,usinganAddendumtothepriorFEISwherenewinformationoranalysisdoesnotsubstantiallychangepriorconclusionsaboutimpacts(WAC197-11-706).Proposedresidentiallandincludesapartmentsandattachedtownhomesthataregenerallybetweentwoandfourstoriesinheight,extendingtofiveandsixstoriesalongSR900.Proposedcommercialspacewouldequalbetween19,500-59,000squarefeet.ProjectLocation:LocatedinnortheastRenton,theSunsetTerracecommunityisgenerallyboundedbySunsetBlvdNEonthesouththatformsa“U-shaped”border,GlenwoodAvenueNEandNE10thStreetonthenorth;HarringtonAvenueNEbisectsthearea.SiteArea:15.28acresProjectLocationMap CityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrativeSitePlanReport&DecisionSUNSETTERRACEREDEVELOPMENTMASTERPLANMINORMODIFICATIONLUA1O-052&LUA14-001475,MODReportofJune20,2016Page2of8A.EXHIBITS:Exhibit1:ERCReport,datedJune13,2016Exhibit2:RentonSunsetAreaReevaluationandAddendum,datedMay2016Exhibit3:DraftNEPA/SEPAEISExhibit4:FinalEIS(2011)Exhibit5:RecordofDecision(2014)Exhibit6:PlannedActionOrdinance(2014)Exhibit7:RevisedMitigationMeasures(2014)Exhibit8:TrafficAnalysis—SunsetMasterPlan(2014)Exhibit9:MasterSitePlan(2016)Exhibit10:MasterSitePlan(2014)Exhibit11:CulturalResourceAssessment(2016)Exhibit12:TrafficAnalysis—SunsetCourt(2016)Exhibit13:HEXDecision—RentonSunsetTerraceRedevelopmentMasterSitePlan—January14,2015Exhibit14:AdministrativeSitePlanReport&Decision—June20,2016B.GENERALINFORMATION:CityofRenton1.Owner(s)ofRecord:RentonHousingAuthoritySunsetTerraceDevelopmentLLC2.ComprehensivePlanLandUseDesignation:CenterVillage(CV)3.ZoningClassification:CenterVillage(CV)andResidential-14(R-14)4.ExistingSiteUse:Multi-FamilyResidential,PublicLibrary,Vacant5.NeighborhoodCharacteristics:a.North:Multi-FamilyResidential(R-14andCVzone)b.East:Multi-FamilyResidentialandCommercial(CVzone)c.South:SunsetBlvdNE/SR900d.West:Multi-FamilyResidential(R-10andCVzone)6.SiteArea:16.88acresC.HISTORICAL/BACKGROUND:ActionLandUseFileNo.OrdinanceNo.DateComprehensivePlanN/A509911/01/2004ZoningN/A510011/01/2004AnnexationN/A179109/09/1959SunsetLaneStreetVacationVAC13-001569309/09/2013LLALUA3-001114N/A10/10/2013SunsetAreaPlannedActionLUA1O-052N/A06/06/2011EISHighlandsLibraryLUA13-001720N/A03/04/2014SitePlanReport CityofRentonDepartmentofCommunity&EconomicDevelopmentSUNSETTERRACEREDEVELOPMENTMASTERPLANMINORMODIFICATIONReportofJune20,2016SunsetLLALUA6-000132N/A04/28/2016SunsetCourtLUA16-000068N/ATBDD.PUBLICSERVICES:1.ExistingUtilitiesa.Water:WaterservicewouldbeprovidedbytheCityofRenton.b.Sewer:SewerservicewouldbeprovidedbytheCityofRenton.c.Surface/StormWater:TherearestormdrainageimprovementsinNE10thSt,SunsetLaneNEandHarringtonAveNE.2.Streets:Therearepartialstreetimprovementsalongthefrontagesofthesite.3.FireProtection:CityofRentonFireDepartmentE.APPLICABLESECTIONSOFTHERENTONMUNICIPALCODE:1.Chapter2LandUseDistrictsa.Section4-2-020:PurposeandIntentofZoningDistrictsb.Section4-2-070:ZoningUseTablec.Section4-2-11OA:ResidentialDevelopmentStandardsd.Section4-2-120A:CommercialDevelopmentStandards2.Chapter3EnvironmentalRegulationsa.Section4-3-100:UrbanDesignRegulations3.Chapter4PropertyDevelopmentStandards4.Chapter6StreetsandUtilityStandards5.Chapter9ProceduresandReviewCriteriaa.Section4-9-200:SitePlanReview6.Chapter11DefinitionsF.ADMINSTRATIVESITEPLANREVIEWFINDINGSOFFACT:1.TheCityofRenton,alongwiththeRentonHousingAuthority(RHA),KingCountyLibrarySystem,andColpittsDevelopment,andcommunitypartners,isredevelopingtheSunsetTerracepublichousingcommunity,anapproximately16-acresitewithinthelargerSunsetAreaCommunityNeighborhoodinnortheastRenton.2.Intotal,722dwellingunitswereapprovedonsitesAthrough0andX.Approximately675oftheseunitswereapprovedonMasterPlansitesCthrough0(Exhibit13).Additionally,therewasarangeofcommercialspaceapprovedwithalowendof19,500squarefeetandanupperrangeof59,000squarefeet.AdministrativeSitePlanReport&DecisionLUA1O-052&LUA14-001475,MODPage3of8SitePlanReport 3.TheRentonSunsetTerraceRedevelopmenttofourconditionsofapproval(Exhibit12):2)AllphasesincludedintheMasterSiteClassificationMap,(StaffReportExhibitsubmittedatthetimeofSitePlanReviewCurrentPlanningProjectManagerandPlanCityandColpittspriortowhichintendstoutilizePlanshallcomplywiththeSunsetAreaStreet12).ConceptualfrontageimprovementsshallbeforeachphaseandaresubjecttoapprovalbytheReviewer.3)Priortobeginningconstruction,eachindividualprojectphaseorimprovementshallprovideinformationtosurroundingpropertyownersabouttimelines,extentofconstruction,andcontactinformation.4)ThisdecisioniseffectiveuntilJanuary14,2025.4.TherequestedmodificationtotheapprovedSunsetTerraceRedevelopmentMasterSitePlanincludesthefollowingchanges:•ShiftsevenunitsfromtheSunsetTerraceApartments(SiteD)totheSunsetParkEast(Piha)Townhomes&Apts(a.k.a.Suncrest)property(SiteG);and•DevelopreplacementhousingfortheRHASunsetTerraceRedevelopmentonfiveparcelslocatedoutsidebutabuttingthe2014MasterPlanarea.ThreeparcelswouldbeaddedtotheCityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrativeSitePlanRepart&DecisionSUNSETTERRACEREDEVELOPMENTMASTERPLANMINORMODIFICATIONLUAO-052&LUA14-001475,MODReportofJune20,2016Page4of8TotalUnitsProp-ReviewedSiteNameStatusAcresosedinUnitsReevaluationAGlennwoodTownhomesConstructedRHA0.6588BKirklandAvenueTownhomesConstructedRHA0.771818CEdmondsApartmentsMasterSitePlan1.799112DSunsetTerraceApartmentsMasterSitePlan0.514154ESunsetParkWestTownhomesMasterSitePlan0.551010FSunsetCourtTownhomesMasterSitePlan0.881515SunsetParkEast(Piha)GMasterSitePlan1.095657Townhomes&AptsHSunsetTerraceDev.BuildingAMasterSitePlan0.56111117ISunsetTerraceDev.BuildingBMasterSitePlan1.18188196JSunsetTerraceDev.BuildingCMasterSitePlan0.74104110KRentonHighlandsLibraryMasterSitePlan0.43LRegionalStormwaterFacilityMasterSitePlanSeeMMSunsetParkMasterSitePlan3.2NSunsetLaneLoopImprovementsMasterSitePlan1.41NE10thStreetExtension0MasterSitePlan0.2ImprovementsXLibrarySite(2013)FutureDevelopment1.412525Totals15.28675722MasterSitePlanwasapprovedonJanuary14,2015subject1)ADevelopment/DensityTransferAgreementshallbeexecutedbythedetailedSitePlanReviewapprovalforanyphaseofdevelopmentunusedresidentialdensityfromtheproposedparkacreage.SitePlanReport CityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrativeSitePlanReport&DecisionSUNSETTERRACEREDEVELOPMENTMASTERPLANMINORMODIFICATIONLUA1O-052&LUA14-001475,MODReportofJune20,2016PageSof8SunsetCourtParksite(SiteF)anddevelopedwith50apartmentsandtownhomes(LUA16-000068),andtwoparcelswouldbeaddedtopropertiesnorthofthe“looproad”intheSunsetParkWestTownhomes(a.k.a.HarringtonPark)developmentresultingin19townhomes(SiteE).TotalUnitsTotalUnits.Acres:ReviewedinReviewedinSiteNameStatusAcres:20162014Reevaluation:Reevaluation:20142016AGlennwoodTownhomesConstructedRHA0.6580.658BKirklandAvenueIownhomesConstructedRHA0.77180.7718CEdmondsApartmentsPartofMasterSitePlan1.701121.7068DSunsetTerraceApartmentsPartofMasterSitePlan0.51540.5147ESunsetParkWestTownhomes2014/HarringtonPark2016PartofMasterSitePlan,Amended0.55101.0619FSunsetCourtTownhomes2014/SunsetCourtApartments2016PartofMasterSitePlan,Amended0.88151.95500SunsetParkEast(Piha)Townhomes&Apts2014/SuncrestHomes2016PartofMasterSitePlan1.09571.0964HSunsetTerraceDcv.BuildingAPartofMasterSitePlan0.091170.99117ISunsetTerraceDcv.BuildingBPartofMasterSitePlan1.181961.18196JSunsetTerraceDec.BuildingCPartofMasterSitePlan0.741100.74110KRentonHighlandsLibraryPartofMasterSitePlanSeeHSeeHCRegionalStormwaterFacilityPartofMasterSitePlanSeeMSeeMMSunsetParkPartofMasterSitePlan3.203.2NSunsetLaneLoopimprovementsPartofMasterSitePlan1.411.410NE10thStreetEutensionImprovementsPartofMasterSitePlan0.200.20XLibrurySite(2013)FutureDevelopment1.41251.4125TotalMasterPlanSites12.4467114.04671Total-AllSites15.287221B.88722=MasterPlanProperties5.TheCityhaspreparedanEnvironmentalImpactStatement(EIS)fortheSunsetArea(Exhibit4),supplementedbyaddenda,thataddressestheprobablesignificantenvironmentalimpactsassociatedwiththelocation,type,andamountofdevelopmentanticipatedinthePlannedActionarea.6.TheCityadoptedaPlannedActionOrdinance5610onJune13,2011,andsubsequentlyreplaceditwithOrdinance5740onDecember8,2014(Exhibit6)toreflectpreparationofaMasterPlanfortheRentonSunsetTerraceRedevelopmentareawithinthelargerPlannedActionAreaandtoreflectintegrationofaSEPAReevaluationAlternativein2014(Exhibit10).7.WiththecurrentlyproposedrevisionstotheMasterPlanandadditionoftheabuttingparcels,therewouldbenonetincreaseinthetotalnumberofhousingunitsintheMasterPlanareaorintheSunsetAreaneighborhood.However,consistentwiththeflexibilityallowedbytheadoptedMasterPlan,someunitswouldberedistributed.8.ThepropertyislocatedwithintheCenterVillage(CV)landusedesignationandtheCenterVillage(CV)andResidential-14du/aczoningclassifications.9.ThesiteislocatedwithinZone2oftheAquiferprotectionArea.Therearenoothercriticalareaslocatedonsite.10.ThePlanningDivisionoftheCityofRentonacceptedtheabovemasterapplicationforreviewonJanuary29,2016,determineditcompleteonFebruary19,2016andcommencedatwoweekpubliccommentperiod.11.Duringstaff’sreviewitwasdeterminedadditionalinformationwasneededinordertoproceedfurther.TheprojectwasplacedonholdonMarch20,2016.TheCityreceivedslightrevisionstotheapplication,theprojectwastakenoffholdonMay27,2016,andasecondcourtesytwo-weekpubliccommentperiodcommencedandwasheldopenuntilJune10,2016.12.Theprojectcomplieswiththe120-dayreviewperiod.13.Noagencyorpubliccommentswerereceived.SitePlanReport CityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrativeSitePlanReport&DecisionSUNSETTERRACEREDEVELOPMENTMASTERPLANMINORMODIFICATIONLUA1O-052&LUA14-001475,MODReportofJune20,2016Page6of814.Representativesfromvariouscitydepartmentshavereviewedtheapplicationmaterialstoidentifyandaddressissuesraisedbytheproposeddevelopment.Thesecommentsarecontainedintheofficialfile,andtheessenceofthecommentshavebeenincorporatedintotheappropriatesectionsofthisreportandtheDepartmentalRecommendationattheendofthisreport.15.MinorModification:TheproposalrequiresaMinorModificationtotheapprovedMasterSitePlanapprovedonJanuary14,2015(Exhibit13).ThefollowingtablecontainsprojectelementsintendedtocomplywiththeminormodificationtoapprovedSitePlanscriteria,asoutlinedinRMC4-9-200H.2:TableA:MINORMODIFICATIONTOANAPPROVEDMASTERPLANORSITEPLANMinormodificationsmaybepermittedbyadministrativedetermination.Tobeconsideredaminormodification,theamendmentmustnot:Involvemorethanatenpercent(10%)increaseinareaorscaleofthedevelopmentintheapprovedplan.StaffComment:Withthe2016/currentlyproposedrevisionstotheMasterSitePlanandadditionoftheabuttingparcels,therewouldbenonetincreaseinthetotalnumberof‘housingunitsintheMasterPlanareaorintheSunsetAreaneighborhood.However,consistentwiththeflexibilityallowedbytheadoptedMasterPlan,someunitswouldberedistributed.TheproposeddevelopmentswouldmeetCitystandardsfordensity,height,setbacks,transportationlevelsofservice,connectiontoutilities,andwouldbesubjecttoCityparkingcodes,includingproceduresformodifyingapplicablestandards.Haveasignificantlygreaterimpactontheenvironmentand/orpublicfacilitiesthantheapprovedplan.StaffComment:Mostoftheoriginalcomponentsofthe2014MasterSitePlan(Exhibit10)remainthesameandcontinuetocomplywithSitePlanReviewdecisioncriteria,asoutlinedinRMC4-9-200.E.Theproposedmodificationwouldberequiredtocontinuetodemonstratecompliancewiththoseconditionsissuedaspartoftheoriginalapproval(seeabove,FindingofFact2).Aswiththechangespreviouslyevaluatedin2014,therevisionsproposedtotheMasterSitePlanatthistimerequireaNEPAReevaluationandSEPAAddendum.AReevaluation,consistentwithapplicableNationalEnvironmentalPolicyAct(NEPA)regulations,combinedwithaSEPAAddendum,waspreparedtoevaluatetheproposedchangesinCompliantiftheMasterSitePlan.TheReevaluation/Addendum,datedMay,2016,concludedthatconditionoftherewerenonewordifferentimpactsandthattheconclusionsoftheEISarestillvalidapprovalis(Exhibit2).metOnJune6,2016,theCity’sEnvironmentalReviewCommitteedeterminedthatthe2016SunsetTerraceRedevelopmentMasterSitePlanModificationwasconsistentwithboththerangeofplanalternativesthatwereevaluatedintheFSEIS(Exhibit4)andwiththedevelopmentlevelsorparametersasspecifiedintherevised2014PlannedActionOridinance(Exhibit6).However,the2016Re-evaluationandAddendumwouldnecessitateminorrevisionstotheRecordofDecisionandPlannedActionOrdinancetoreflecttherevised(2016)MasterSitePlanpriortoconstruction.Thereforestaffrecommendsaconditionofapprovalrequiringallnecessarychanges,reflectingthe2016MasterSitePlanRevisions,bemadetotheRecordofDecisionandPlannedActionOrdinancepriortothecommencementofconstructiononSitesD,EFandG(SunsetTerraceApartments,SunsetParkWestTownhomes,SunsetCourtPark,andSunsetParkEastTownhomes&SitePlanReport CityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrativeSitePlanReport&DecisionSUNSETTERRACEREDEVELOPMENTMASTERPLANMINORMODIFICATIONLUA1O-052&LUA14-001475,MODReportofJune20,2016Page8of8TRANSMITTEDthisthis20thdayofJune2016totheContact/Applicant/Owner:Owners:RentonHousingAuthorityCityofRentonColpittsDevelopmentTRANSMITTEDthisthis20thdayofJune2016tothePartiesofRecord:CoraleeSchutzSharonBarkerHarringtonPlaceCondoManager1100HarringtonAveNE#31115718SEi43dSt716W.MeekerSt#101Renton,WA98056Renton,WA98059Kent.WA98032SandraBowersAlD’AlessandroMatt&CindyGano1135HarringtonAveNEKingCounty1145HarringtonAveNERenton,WA980564015thAye,Ste#500Renton,WA98056Seattle,WA98104TRANSMITTEDthisthis20thdayofJune2016tothefollowing:CE.“Chip”Vincent,CEDAdministratorBrianneBannwarth,DevelopmentEngineeringManagerVanessaDolbee,CurrentPlanningManagerFireMarshalLandUseActionAppeals,RequestforReconsideration,&ExpirationThereviewdecisionswillbecomefinalifthedecisionsarenotappealedwithin14daysofthedecisiondate.MinorModificationtoApprovedSitePlanApprovalAppeal:AppealsoftheadministrativemodificationtoapprovedsiteplanmustbefiledinwritingtotheHearingExamineronorbefore5:00p.m.onJuly5,2016.APPEALS:Anappealofthedecision(s)mustbefiledwithinthe14-dayappealperiod(RCW43.21.C.075(3);WAC197-11-680).RentonMunicipalCodeSection4-8-110governsappealstotheHearingExaminer.Appealsmustbefiledinwritingtogetherwiththe$250.00applicationfeetoHearingExaminer,CityofRenton,1055SouthGradyWay,Renton,WA98057.AdditionalinformationregardingtheappealprocessmaybeobtainedfromtheCityClerk’sOffice,RentonCityHall-7thFloor,(425)430-6510.RECONSIDERATION:Within14daysofthedecisiondate,anypartymayrequestthatadecisionbereopenedbytheAdministrator(Decision-maker).TheAdministrator(Decision-maker)maymodifyhisdecisionifmaterialevidencenotreadilydiscoverablepriortotheoriginaldecisionisfoundorifhefindstherewasmisrepresentationoffact.Afterreviewofthereconsiderationrequest,iftheAdministrator(Decision-maker)findssufficientevidencetoamendtheoriginaldecision,therewillbenofurtherextensionoftheappealperiod.Anypersonwishingtotakefurtheractionmustfileaformalappealwithinthe14-dayappealtimeframe.EXPIRATIONPERIOD:TheAdministrativeSiteDevelopmentPlanReviewdecisionwillexpiretwo(2)yearsfromthedateofdecisionortheexpirationoftheMasterSitePlanwhichevercomesfirst.THEAPPEARANCEOFFAIRNESSDOCTRINE:providesthatnoexparte(privateone-on-one)communicationsmayoccurconcerningthelandusedecision.TheDoctrineappliesnotonlytotheinitialdecision,buttoAppealstotheHearingExamineraswell.Allcommunicationsafterthedecision/approvaldatemustbemadeinwritingthroughtheHearingExaminer.Allcommunicationsarepublicrecordandthispermitsallinterestedpartiestoknowthecontentsofthecommunicationandwouldallowthemtoopenlyrebuttheevidenceinwriting.AnyviolationofthisdoctrinecouldresultintheinvalidationoftheappealbytheCourt.SitePlanReport CityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrativeSitePlanReport&DecisionSUNSETTERRACEREDEVELOPMENTMASTERPLANMINORMODIFICATIONLUA1O-052&LUA14-001475,MODReportofJune20,2016Page7of8Apartmentsrespectively).ItshouldbenotedstaffiscurrentlyprocessingamendmentstotheSunsetAreaPlannedActionOrdinance,pursuanttoSEPA.TheCityheldacommunitymeeting,asrequired,onJune6,2016forproposedamendmentstothePlannedActionOrdinance.TheCityCouncilwillholdapublichearingonJuly11,2016regardingnewamendmentstothePlannedActioninordertointegratethe2016ReevaluationAlternative,outlinedintheNEPAReevaluationandSEPAAddendum(Exhibit2).ItisanticipatedtherevisedPlannedActionOrdinance,andRecordofDecision,willbeeffectiveand/orinplaceinAugustof2016.Themodificationdoesnotchangetheboundariesoftheoriginallyapprovedplan.StaffComment:All2016MasterPlannedsites(Exhibit9)wereevaluatedinthe2011EISfortheSunsetAreaCommunityPlannedActionArea(Exhibit4).ThreeadditionalparcelsvabuttingSunsetCourtPark(Site“F”,a2011‘swapsite”)areaddedtotheMasterPlan,andtwoadditionalparcelsareaddedtotheRedevelopmentarea(Site“E”).MostoftheMasterPlanSitesbeingreviewedinthisdocumentwerepreviouslyconsideredinthePotentialSunsetRedevelopmentStudyAreaorwereconsidered“swapsites”(wherehousingreplacementcouldoccur).G.CONCLUSIONS:1.TheSunsetTerraceRedevelopmentSitePlanMinorModificationisconsistentwiththeMinorModificationcriteriatoanapprovedSitePlan,ifallconditionsofapprovalaremet.2.Theproposaliscompliantandconsistentwiththeplans,policies,regulationsandapprovalstowhichitisvestedifallconditionsofapprovalaremet.3.Staffdoesnotanticipateanyadverseimpactsonsurroundingpropertiesandusesaslongastheconditionsofapprovalarecompliedwith.4.TheproposeduseisanticipatedtobecompatiblewithexistingandfuturesurroundingusesaspermittedintheCVandR-14zoningclassifications.5.Thereareadequatepublicservicesandfacilitiestoaccommodatetheproposeduse.H.DECISION:TheproposedSunsetTerraceRedevelopmentSitePlanMinorModification,FileNo.LUA14-001475andLUA1O-052,MODisapproved.Theproposalissubjecttothefollowingconditions:1.TheapplicantshalldemonstratecompliancewithallconditionsofapprovalissuedaspartoftheSunsetTerraceRedevelopmentMasterSitePlanDecision,datedJanuary14,2015(Exhibit13).2.Allnecessarychanges,reflectingthe2016MasterSitePlanRevisions,shallbemadetotheRecordofDecisionandPlannedActionOrdinancepriortothecommencementofconstructiononSitesD,E,FandG(SunsetTerraceApartments,SunsetParkWestTownhomes,SunsetCourtPark,andSunsetParkEastTownhomes&Apartmentsrespectively).JenniferHenning,PlanningDirectorDateSitePlanReport CityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrativeSitePlanReport&DecisionSUNSETTERRACEREDEVELOPMENTMASTERPLANMINORMODIFICATIONLUA1O-052&LUA14-001475,MODReportofJune20,2016Page8of8TRANSM1?TEDthisthis20thdayofJune2016totheContact/Applicant/Owner:Owners:RentonHousingAuthorityCityofRentonColpittsDevelopmentTRANSMuTEDthisthis20thdayofJune2016tothePartiesofRecord:CoraleeSchutzSharonBarkerHarringtonPlaceCondoManager1100HarringtonAveNE#31115718SE;43rdSt716W.MeekerSt#101Renton,WA98056Renton,WA98059Kent,WA98032SandraBowersAlD’AlessandroMatt&CindyGano1135HarringtonAveNEKingCounty1145HarringtonAveNERenton,WA98056401SthAve,Ste#500Renton,WA98056Seattle,WA98104TRANSMIJTEDthisthis20thdayofJune2016tothefollowing:C.E.“Chip”Vincent,CEDAdministratorBrianneBonnworth,DevelopmentEngineeringManagerVanessaDolbee,CurrentPlanningManagerFireMarshalLandUseActionAppeals,RequestforReconsideration,&ExpirationThereviewdecisionswillbecomefinalifthedecisionsarenotappealedwithin14daysofthedecisiondate.MinorModificationtoApprovedSitePlanApprovalAppeal:AppealsoftheadministrativemodificationtoapprovedsiteplanmustbefiledinwritingtotheHearingExamineronorbefore5:00p.m.onJuly5,2016.APPEALS:Anappealofthedecision(s)mustbefiledwithinthe14-dayappealperiod(RCW43.21.C.075(3);WAC197-11-680).RentonMunicipalCodeSection4-8-110governsappealstotheHearingExaminer.Appealsmustbefiledinwritingtogetherwiththe$250.00applicationfeetoHearingExaminer,CityofRenton,1055SouthGradyWay,Renton,WA98057.AdditionalinformationregardingtheappealprocessmaybeobtainedfromtheCityClerk’sOffice,RentonCityHall-7thFloor,(425)430-6510.RECONSIDERATION:Within14daysofthedecisiondate,anypattymayrequestthatadecisionbereopenedbytheAdministrator(Decision-maker).TheAdministrator(Decision-maker)maymodifyhisdecisionifmaterialevidencenotreadilydiscoverablepriortotheoriginaldecisionisfoundorifhefindstherewasmisrepresentationoffact.Afterreviewofthereconsiderationrequest,iftheAdministrator(Decision-maker)findssufficientevidencetoamendtheoriginaldecision,therewillbenofurtherextensionoftheappealperiod.Anypersonwishingtotakefurtheractionmustfileaformalappealwithinthe14-dayappealtimeframe.EXPIRATIONPERIOD:TheAdministrativeSiteDevelopmentPlanReviewdecisionwillexpiretwo(2)yearsfromthedateofdecisionortheexpirationoftheMasterSitePlanwhichevercomesfirst.THEAPPEARANCEOFFAIRNESSDOCTRINE:providesthatnoexparte(privateone-on-one)communicationsmayoccurconcerningthelandusedecision.TheDoctrineappliesnotonlytotheinitialdecision,buttoAppealstotheHearingExamineraswell.Allcommunicationsafterthedecision/approvaldatemustbemadeinwritingthroughtheHearingExaminer.Allcommunicationsarepublicrecordandthispermitsallinterestedpartiestoknowthecontentsofthecommunicationandwouldallowthemtoopenlyrebuttheevidenceinwriting.AnyviolationofthisdoctrinecouldresultintheinvalidationoftheappealbytheCourt.SitePlanReport EntireDocumentAvailabteUponRequestEXHIBIT3 FULLDOCUMENTAVAILABLEUPONREQUEST)/p.r1i)j-ftyof__enton•Commun;&EconomicDevelopmentEXHIBIT4 FULLDOCUMENTAVAILABLEUPONREQUESTRecordofDecision(Revised)SunsetAreaCommunityPlannedActionEISIntroduction1Background1SummaryofAlternativesConsideredinReachingDecision2PublicInvolvement10CoordinationwithOtherAgencies11FinalElSComments13ClarificationsandCorrections13Attachments13IntroductionTheCouncilonEnvironmentalQuality(CEQ)directstheimplementationoftheNationalEnvironmentalPolicyAct(NEPA).CEQrulesrequireagenciestoprepareaRecordofDecision(ROD)afterpreparinganenvironmentalimpactstatement(FIS)(Title40oftheCodeoftheFederalRegisterpart1505.2).ThepurposeofaRODistoexplainwhytheagencyhastakenaparticularcourseofaction.ARODmustincludethefollowingelements:•Anexplanationofdecisiononaproposedaction;•Factorsconsideredinmakingadecision;•Alternativesconsideredandtheenvironmentallypreferredalternative;•Adoptedmitigationmeasuresorreasonswhymitigationmeasureswerenotadopted;and•Amonitoringandenforcementprogramforadoptedmitigationmeasures.ThisRODaddressestheredevelopmentoftheSunsetTerracepublichousingcommunityanditsrelationshiptoneighborhoodgrowthandrevitalization.GrowthinthebroaderplanningstudyareaisnotpartoftheproposaladdressedintheROD,andcouldoccurindependentoftheSunsetTerraceproposal.BackgroundTheCityofRenton(City)istheResponsibleEntity(RE)andleadagencyforNEPApurposes.InaccordancewithspecificstatutoryauthorityandtheU.S.DepartmentofKousingandUrbanDevelopment’s(HUD’s)regulationsat24CodeofFederalRegulations(CFR)part58,theCityisauthorizedtoassumeresponsibilityforenvironmentalreview,decision-making,andactionthatwouldotherwiseapplytoHUDunderNEPA.Additionally,theCityistheproponentofthebroaderPlannedActionfortheSunsetareawhichhashadenvironmentalreviewunderWashingtonStateEnvironmentalPolicyAct(SEPA)(RevisedCodeofWashington[RCWJ43.21C).RecordofDecisionEXHIBIT5May2011;RevisedNovember2014 FULLDOCUMENTAVAILABLEUPONREQUESTCITYOFRENTON,WASHINGTONORDINANCENO.5740ANORDINANCEOFTHECITYOFRENTON,WASHINGTON,ESTABLISHINGAPLANNEDACTIONFORTHESUNSETAREAPURSUANTTOTHESTATEENVIRONMENTALPOLICYACT.THECITYCOUNCILOFTHECITYOFRENTON,WASHINGTON,DOESORDAINASFOLLOWS:SECTIONI.Findings.TheCouncilfindsasfollows:A.TheCityissubjecttotherequirementsoftheGrowthManagementAct,RCW36.70A(“GMA”)andislocatedwithinanUrbanGrowthArea;B.TheCityhasadoptedaComprehensivePlancomplyingwiththeGMA,andhasamendedtheComprehensivePlantoaddresstransportationimprovementsandcapitalfacilitiesspecifictotheSunsetArea;C.TheCityhasadoptedaCommunityInvestmentStrategy,developmentregulations,anddesignguidelinesspecifictotheSunsetAreawhichwillguidegrowthandrevitalizationofthearea,includingtheSunsetTerracepublichousingproject;D.TheCityhaspreparedanEnvironmentalImpactStatement(EIS)fortheSunsetArea,supplementedbyanaddendum,thataddressestheprobablesignificantenvironmentalimpactsassociatedwiththelocation,type,andamountofdevelopmentanticipatedinthePlannedActionarea;E.ThemitigationmeasuresidentifiedinthePlannedActionEIS,andattachedtothisordinanceasAttachmentB,togetherwithadoptedCitydevelopmentregulations,willEXHIBIT6I FULLDOCUMENTAVAILABLEUPONREQUESTAttachmentB:SunsetAreaCommunityI’IanneuMcIUflEISMitigationMeasuresTableofContentsIntroductionandPurpose3SEPATerms3GeneralInterpretation3SummaryofProposal,Alternatives,andLandCapacity4ProposalandAlternatives4LandCapacity5Location6MitigationDocument71.Earth82.AirQuality103.WaterResources164.PlantsandAnimals195.Energy216.Noise237.EnvironmentalHealth258.LandUse289.Socloeconomics3010.Housing3211.EnvironmentalJustice3412.Aesthetics3613.Historic/Cultural3914.Transportation4215.ParksandRecreation4616.PublicServices4917.Utilities54AdvisoryNotes59Attachment1:DraftEIS,CulturalResourcesAppendixi,PlanandProceduresforDealingwiththeUnanticipatedDiscovery60Attachment2:Figure3.17-1PotentialSubareaUtilityImprovementsandPhasing62Water63Overview63Edmonds-GlenwoodPhase163NewLibrary63NewMixed-UseBuildingAdjacenttoNewLibrary64RHA’sPihaSite64__EXHIBIT7______________PlannedActionOrdinanceAttachmentB:MitigationDocument CH2MH1LLSL.EntireDocumentAvailableUponRequestSunsetAreaCommunityPlannedActiTrafficAnalysisResults-May2014RedevelopmentMasterSitePlanAlternativeINTRODUCTIONThismemorandumprovidestrafficanalysisresultsfortheMay2014RedevelopmentMasterSitePlanAlternative,orReevaluationAlternative,oftheSunsetAreaCommunityPlannedAction,andcomparestheseresultswithoperationsforAlternative3andthePreferredAlternativeasdocumentedintheFinalNEPA/SEPAFIS.ComparedtoAlternative3,theReevaluationAlternativeincludesamaximumof90additionalunitsinthePotentialSunsetTerraceRedevelopmentSubarea.These90additionalunitsareshiftedoutoftheNorth,South,andSunsetMixedUseareasofthePlannedActionstudyarea.ThisanalysisfocusesontheintersectionoperationsexpectedasaresultofthisshiftTRIPGENERATIoNANDDISTRIBUTIONTripsgeneratedbyAlternative3andthePreferredAlternativeinthePlannedActionstudyareawereestimatedusingtheCity’sversionofthePSRCregionaltravelforecastingmodelwithappliedfuture-yearproposedlanduses.TheAlternative3trafficvolumes,asanalyzedintheFinalNEPA/SEPAEIS,wereusedasabasetodeveloptheReevaluationAlternativevolumes.Tripsgeneratedbythe90additionalunitswereremovedfromtheNorth,South,andSunsetMixedUseareas,andre-routedtothePotentialSunsetTerraceRedevelopment.Assumingthe90shiftedhousingunitsconsistofmediumtohighdensitylow-riseapartmentdwellings,approximately61trips7wouldbegeneratedduringtheweekdayPMpeakhour.(Source:InstituteofTransportationEngineers,TripGenerationManual,9thEdition,InstituteofTransportationEngineers.)Approximatelyhalfoftheunits(47units)wouldbeshiftedfromtheNorthsubarea,37percent(33units)wouldbeshiftedfromtheSouthsubarea,andtheremaining11percent(10units)wouldcomefromthenortheastendoftheSunsetMixedUsesubarea.TRAFFICANALYSISRESULTSTrafficanalysisresultswerecalculatedforthePMpeakhourfortheyears2015and2030.Ingeneral,futuretrafficpatternsintheReevaluationAlternativewoulddifferslightlyfromboththePreferredAlternativeandAlternative3.ThesewouldbenewtripstothePotentialSunsetTerraceRedevelopmentarea,butshiftedfromotherareasofthePlannedActionneighborhood.1EXHIBIT8 Cu0a)IU)Cu-J—w—<zzw1-1I-.’a)0Cu0L..U)—I’‘3dw1—-I--aa)CoU)K—0=I—zC,.)w a)U)a)U)G)0Cuci)ci)U)CU)0‘.41—mI-IzzzUEXHIBIT30U)wI—wC’,zDU)z0Ui>.QøI FULLDOCUMENTAvUPONREQUESTCulturalResourceConsultants,Inc.TECHNICALMEMO1507F-2DATE:September11,2015TO:KevinGiffordBerkConsultingFROM:GlennHartmann,PrincipalInvestigatorRE:CulturalResourcesAssessmentfortheSunsetCourtApartmentsProject,Renton,WATheattachedshortreportformconstitutesourfinalreportfortheabovereferencedproject.Assessmentdidnotidentifyarchaeologicalresourcesthatcouldbeaffectedbythisproject.Fourstructuresbuiltover50yearsagoarelocatedonthesubjectparcels;however,thesedonotmeetminimumcriteriaforeligibilityforstateornationalhistoricregistereligibility.Historicinventoryformsforthestructuresandaninadvertentdiscoveryplanareattached.Pleasecontactthisofficeshouldyouhaveanyquestionsaboutourfindingsandlorrecommendations.197PARFIUWAYSW,SuITE100P0Box10668,BAINBRIDGEISLAND,WA98110PHONE206855-9020-inlo@crcwa.com FULLDOCUMENTAVAILABLEUPONREQUESTPerteet5055thAvenue5,Suite300Seattle,WA981041.800.615.9900/206.436.0515AllyCommunityDevelopment,LLCTrafficImpactAnalysisSunsetCourtSeptember10,2015/1tJlEXHIBIT12 FULLDOCUMENTAVAILABLEUPONREQUEST12345678BEFORETHEHEARINGEXAMINERFORTHECITYOFRENTON9)RE:RentonSunsetTerrace)10.)FINALDECISIONRedevelopmentMasterSitePlan11)SitePlan,ConditionalUsePermit)12)LUA14-00001475,SA-M,CUP)13_____________________________________________1415SUMMARY16TheCityhasrequestedMasterSitePlanreviewandaConditionalUsePermittomodifytheSunset17TerraceRedevelopmentAreabyadding90additionalresidentialunits,increasinatheheightlimitandlotcoveragerequirementsandreducingsetbacks.TheCityhasalsorequesteãachangeintheisvestingtimeline.TheMasterSitePlanReviewandConditionalUsePermitareapprovedwithconditions.The10yearexpirationrequestisgranted.1920TESTIMONY21RocaleTiinmons,seniorplanner,describedthehistoryoftheprojectandtheprogresstodate.Shedescribedthesitecharacteristicsandtherevisionsbeingrequestedforthisprocess.Ms.Timrnons22statedsince2011,therehavebeensomeentitlementsoflanduses.TheCityanditspartnershave23reevaluatedtheoriginalMasterSitePlansincethe2011approvalsofthePlannedActionOrdinanceandissuanceoftheFEIS.ThepreferredalternativewasAlternative3fromtheFEIS.TheCityandits24partnersarerequestingseveralchangestothepreferredalternativeincludingtheadditionof90moreresidentialunits,increasedbuildingheights,reducedsetbacks,increasedlotcoveragesand25reclassificationoflocalstreets.Inreturn,theCitywillbeabletoexpandtheproposedpublicparkto263.2acres.EXHIBIT13SITEPLAN,CRITICALAREASEXEMPTION,STREETMODWICATION,ANDLOTLINEADJUSTMENT-1 1 2 3 4 5 6 7 8 BEFORE THE HEARING EXAMINER FOR THE CITY OF RENTON 9 10 RE: Renton Sunset Terrace FINAL DECISIONRedevelopmentMasterSitePlan ) 11 Site Plan, Conditional Use Permit ) 12 LUA14-001475, SA-M, CUP 13 14 15 SUMMARY 16 The City has requested Master Site Plan review and a Conditional Use Permit to modify the Sunset 17 Terrace Redevelopment Area by adding 90 additional residential units, increasing the height limit and lot coverage requirements and reducing setbacks. The City has also requested a change in the 18 vesting timeline. The Master Site Plan Review and Conditional Use Permit are approved with 19 conditions. The 10 year expiration request is granted. 20 TESTIMONY 21 Rocale Timmons, senior planner, described the history of the project and the progress to date. She described the site characteristics and the revisions being requested for this process. Ms. Timmons 22 stated since 2011, there have been some entitlements of land uses. The City and its partners have 23 reevaluated the original Master Site Plan since the 2011 approvals of the Planned Action Ordinance and issuance of the FEIS. The preferred alternative was Alternative 3 from the FEIS. The City and its 24 partners are requesting several changes to the preferred alternative including the addition of 90 more residential units, increased building heights, reduced setbacks, increased lot coverages and 25 reclassification of local streets. In return, the City will be able to expand the proposed public park to 26 13.2 acres. SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 1 I The City is requesting Master Site Plan review at this stage to allow for the proposed changes. This is 2 not site plan review for individual project components; that will come later. This decision is conceptual only in nature. As proposed and conditioned, all zoning, development standards and 3 design standards will be met. The decision today covers only lot coverage, residential density, building height and an increased timeline for vesting. The hope is to streamline the process going 4 forward and to reflect the revised design. Approval of the Master Site Plan and Conditional Use Permit will facilitate phased site planning over time and provide more certainty to the development5partners. The CUP approval is for the height increase. The City would like this project to have a 10 6 year vesting timeline. 7 All environmental review has been accomplished as either part of the initial FEIS for the original Master Site Plan are as amended for the revised Master Site Plan. No new or different impacts are 8 anticipated from the proposed changes. Demolition and Disposition Permits for all public housing has 9 already been approved by HUD. All affected families in public housing have already received either vouchers or relocation assistance. No public comments were received regarding the proposed 10 revisions to the approved Master Site Plan. 11 The additional units will pay impact fees and development charges based on school district and City 12 requirements. The project includes installation of a regional stormwater system, though each individual development will provide for its own stormwater. 13 Public Testimony 14 Larry Joel Dean of 1100 Harrington Avenue NE lives in the redevelopment master plan area. He 15 spoke generally in favor of the project, but had several items of concern. He understands this is a long 16 term project with many phases, but has been living in an active construction zone for a long time. He is looking forward to the completion of the project. 17 Mr. Dean is president of the homeowners association for Olympic Condos, which represents 29 units 18 in the center of the master plan. He stated his residents feel ignored by the City and communication 19 has been inadequate. Specifically, Mr. Dean related the story of the road construction work that occurred over the Christmas break. The contractor failed to place a steel plate over the driveway to 20 the condos. As a result, a resident got their car stuck in the gap and had to have the vehicle towed. The contractor eventually returned from the break and placed the steel plate in place, but only after 21 the damage was done. 22 Mr. Dean stated he was concerned about the reduced setbacks along SR 900 and the increased 23 building height. He currently lives next to a vacant lot that is slated to become a six story building. He reiterated he is generally very supportive of the project, but is concerned about communication with 24 and from the City. 25 26 SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 2 I Staff Rebuttal 2 Rocale Timmons apologized for the incident with the steel plate. She explained the project timeline, 3 which is in excess of ten years. She also stated the road improvements along Harrington Road will likely last another six months. Ms. Timmons stated the City would support a condition of approval 4 that required notification in addition to what is currently required by City code, such as asking each individual phase to provide information to surrounding property owners about timelines and contact 5 information. 6 EXHIBITS 7 8 The December 30, 2014 staff report Exhibits 1-15 identified at page 2 of the staff report itself 9 were admitted into the record during the hearing. The staff PowerPoint was admitted as Exhibit 16 during the hearing. 10 11 FINDINGS OF FACT 12 13 Procedural: 14 1.Applicant. The applicants are the City of Renton, the Renton Housing Authority and the Sunset Terrace Development, LLC. 15 2. Hearing. The Examiner held a hearing on the subject application on December 30, 2014 at1610:00 am in the City of Renton Council Chambers. 17 3.Project Description. Sunset Terrace in northeast Renton is the oldest multifamily public 18 housing complex directly managed by the Renton Housing Authority. It was constructed in 1959 and 19 contains 110 dwelling units in 27 buildings. The City of Renton, along with the Renton Housing Authority (RHA), the King County Library System, Colipitts Development, and community partners, 20 is redeveloping approximately 15.28-acres of Sunset Terrace within the larger Sunset Area 21 Community Neighborhood. 22 The Sunset Terrace public housing community is generally bounded by Sunset Lane NE and Glenwood Avenue NE on the north, NE 10th Street on the east, NE Sunset Boulevard (State Route 23 [ SR] 900) on the south, and Edmonds Avenue NE on the west. RHA owns additional vacant and 24 residential land along Edmonds Avenue NE, Glenwood Avenue NE, Harrington Ave NE, Kirkland Ave NE, and Sunset Lane NE, and the Authority plans to incorporate these additional properties into25 the Sunset Terrace redevelopment for housing and associated services. 26 SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 3 I Redevelopment of this area envisions Sunset Terrace as a mixed-use, mixed-income community 2 anchored by a new public library and a new park. Mixed-use sites will have both market rate and affordable rental housing in multi-story, multi-family townhomes and apartments, along with 3 commercial and retail space. Proposed residential land includes apartments and attached townhomes 4 that are generally between two and four stories in height, extending to five and six stories along SR 900, which will provide 722 total dwelling units. Proposed commercial space would equal between 5 19,500-59,OOOsf, with 15,OOOsf consisting of a newly relocated Renton Highlands Library (this use 6 has already been permitted and is under construction), and the rest consisting of retail or office space depending on market needs. 7 The NEPA/SEPA Final Environmental Impact Statement (FEIS) was issued on April 1, 2011. The 8 City completed a Record of Decision (ROD) in accordance with the National Environmental Policy 9 Act (NEPA) to redevelop the 15.28 acre Sunset Terrace public housing community (May 2011) into a mixed use, mixed density, mixed income community anchored by a new public park and library. The10 City also completed Planned Action Ordinance (#5610) in accordance with the State Environmental 11 Policy Act (SEPA). Since the original FEIS analysis, redevelopment efforts have continued and 12 additional site planning has occurred. As a consequence, the applicants are now proposing changes to the number and configuration of units. 13 The revised development proposal will add 90 more units to the Sunset Terrace area, though the 14 neighborhood total will remain the same. Also, the City has reconfigured the proposed public park 15 and expanded it to 3.2 acres. This required a reduction in the footprint of the adjacent buildings and commensurate increases in building heights and density at these locations. To do this, the City must 16 increase the lot coverage and building heights within the Sunset Terrace area and reduce the required 17 street setbacks. The original FEIS Preferred Alternative (#3), Record of Decision and Planned Action Ordinance contemplated 90 fewer units, larger setbacks from SR 900, shorter buildings and different 18 street profiles. 19 To accomplish these changes, a NEPA Reevaluation, pursuant to Section 58.47 of US Department of 20 Housing and Urban Development's (HUD's)NEPA regulations, is required. The NEPA Reevaluation 21 must demonstrate the original conclusions of the FEIS remain valid. SEPA also provides a process, using an Addendum to the prior FEIS where new information or analysis does not substantially 22 change prior conclusions about impacts (WAC 197-11-706). A Reevaluation, consistent with 23 applicable National Environmental Policy Act (NEPA) regulations and a SEPA addendum, was prepared to evaluate the proposed changes to the Master Site Plan. The Reevaluation and Addendum 24 (December 8, 2014) concluded there are no new or different impacts resulting from the change and 25 the conclusions of the FEIS are still valid. 26 SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 4 I To accommodate the localized change in density, the City has requested Master Site Plan review. The 2 City has requested a Conditional Use Permit to increase the height limit and lot coverage requirements and reduce setbacks in the areas proposed for additional units. The City has also 3 requested an extension of the vesting timeline to 10 years. 4 In total, there will be 722 dwelling units (including the 90 additional units requested under the present 5 proposal). Twenty six of the units have already been constructed by the Renton Housing Authority 6 ( RHA). The 90 additional units will be spread across Master Plan Sites C, D, E, F, G, H, I and J. Site C: The RHA Edmonds Apartments site is approximately 1.7 acres within the Center Village7 ( CV) zone. Proposed for the site is a four-story multi-family building, over one-story of structured 8 parking, containing no more than 112 apartment units. The proposed building height is 50 feet and 9 would orient towards Edmonds Avenue NE, with a direct sidewalk connection. The original proposal had contemplated 99 units for this site. 10 Site D: The RHA Sunset Terrace Apartments site is approximately 0.51 acres within the CV Zone. 11 Proposed for the site is a five-story multi-family building containing no more than 54 apartment units. 12 The FEIS Preferred Alternative had contemplated 41 units on this site. Units may be redistributed among Sites D and G provided the NEPA Reevaluation conclusions are maintained (Staff Report 13 Exhibit 2). The proposed building height is 60 feet and would orient towards Sunset Lane NE, with a 14 direct sidewalk connection. Parking is anticipated to be under building. 15 Site E: The RHA Sunset Park West Townhomes site is approximately 0.55 acres and is zoned Residential-14. The proposed development consists of two, three-story, multi-family residential16 buildings with associated garage parking. These buildings contain eight apartment and ten townhome 17 dwelling units for a total of 18 units. 18 Site F: The RHA Sunset Court Townhomes site is approximately 0.88 acres and is zoned CV. The 19 proposed development consists of two, two-story, multi-family residential buildings with associated surface parking. These buildings contain ten townhome dwelling units. The proposed building height 20 is 30 feet'. 21 22 1 The Staff Report Findings No. 6 lists this site as having a total of 10 units in the approved and revised site plans. The language above is from Staff Report Finding No. 10. The chart on page 4 of the Staff Report limits the total 23 units to 722. This decision is for a conceptual site plan limited to a total of 722 units to be constructed in several phases and in several different buildings and locations. If the City wishes to increase the total number of units to 24 account for the discrepancy between the Staff Report Findings for Site E, they are encouraged to request a reconsideration. 25 2 There is also a discrepancy between the Staff Report Finding Nos. 6 and 11 with respect to the total number of 26 units proposed for this site. As noted above, this decision limits the total number of units in the Master Site Plan to 722. SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 5 I Site G: The RHA Sunset Park Townhomes East (Piha) site is approximately 1.09 acres in size and 2 zoned CV. The proposed development consists of three multi-story, multi-family residential buildings with a below grade parking structure. Future plans include 3 buildings containing a total of 57 multi- 3 family units with a mix of 1, 2, and 3-bedroom units. Units may be redistributed among Sites D and 4 G provided the NEPA Revaluation conclusions are maintained (Exhibit 2). The buildings range in height from two to four stories, and the overall proposed building height is 48 feet. Proposed off-site 5 improvements include a new sidewalk along Sunset Lane NE. The FEIS considered 56 units for this 6 site. 7 Site H: The Colpitts Sunset Terrace Development Building A site is approximately 0.99 acres and is located within the CV zone. A six-story, 68-foot tall, mixed-use building with associated structured 8 parking is proposed for the site. The building would contain a total of 117 residential units (up from 9 111 units in the original proposal) and about 19,500sf of commercial space including a 15,OOOsf King County Library facility (LUA13-001720). Units between sites H, I, and J may be redistributed at the10 time of Site Plan Review. 11 Site I: The Colpitts Sunset Terrace Development Building B site is approximately 1.18 acres and is 12 located within the CV Zone. A six-story, 62-foot tall, multi-family project with associated structured 13 parking is proposed for the site. The building would contain a total of 196 residential units. The FEIS had considered 188 units for this site. Units between sites H, I, and J may be redistributed at the time 14 of Site Plan Review. Vehicular access to structured parking on the site would be provided at multiple 15 points along Sunset Lane NE. Pedestrian access to a residential lobby would also occur from Sunset Lane NE. 16 Site J: The Colpitts Sunset Terrace Development Building C site is approximately 0.74 acres and is 17 located within the CV zone. A five-story multi-family project with associated structured parking is 18 proposed for the site. The building would contain a total of approximately 110 residential units (up 19 from 104 units). Units between sites H, I, and J may be redistributed at the time of Site Plan Review. 20 Mixed-use sites will have both market rate and affordable rental housing in multi-story, multi-family townhomes and apartments, along with commercial and retail space. Defining features of the site plan 21 include: 22 An expanded Sunset Neighborhood Park centrally located within the site. 23 A circular local road system that facilitates circulation around the park, connecting Sunset 24 Lane,NE 10th, and the southern end of Glenwood Avenue NE. 25 Compatibility with future multimodal SR 900 improvements. 26 SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 6 1 Mixed-use development with residential and commercial uses including retail space and a 2 library. 3 A Library situated at the corner of NE 10th and Sunset Blvd NE across from the proposed 4 expanded park (LUA13-001720). 5 The site is located within Zone 2 of the Aquifer protection Area. There are no other critical areas located on site. 6 The property is zoned Center Village (CV) and Residential-14 (R-14). The Comprehensive Plan 7 designation is Center Village. To the north is multi-family residential (R-14 and CV zones). To the 8 east are multi-family residential and commercial uses (CV zone). To the south is Sunset Boulevard/SR 900. To the west is multi-family residential (R-10 and CV zone). The proposal 9 involves multi-family, commercial, institutional and public uses. 10 4. Adequacy of Infrastructure/Public Services. The project will be served by adequate 11 infrastructure and public services as follows: 12 A. Water and Sewer Service. The site is served by the City of Renton for all water and sewer 13 service. The proposal is a conceptual Master Site Plan for a multi-phase development over a large subarea. This topic will be reviewed with detailed Site Plan Review for each phase. 14 A conceptual water main improvements layout for the proposed developments identified 15 has been developed (Staff Report Exhibit 13). The diagram updates the information contained in the Final EIS as amended in the NEPA/SEPA Reevaluation/Addendum, but 16 is intended to meet City standards as described in the Final EIS. 17 The City will require 12-inch water mains in all new public streets (Harrington Ave NE, 18 Sunset Lane NE, NE 10th Street, Glennwood Ave NE) to provide the estimated fire flow 19 demand ranging from 3,000 gpm to 4,000 gpm based on the City Fire Prevention's review of various pre-application submittals. A developer's extension of the section of 12-inch 20 water main in Sunset Blvd NE/SR 900 will be required to be a looped water system 21 because the estimated fire flow demand for the proposed development on Site H and on Site I is above 2,500 gpm. 22 23 The location of the new water main in SR 900 west of Harrington will be evaluated as part of the pre-design/design of the roadway improvements projects, and consider the need to 24 accommodate existing and future public and private utilities, rockery/retaining walls, 25 street trees, etc. 26 SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 7 I Sites plans will be required to show the location of the existing sewer system in order to 2 determine the potential re-use of existing sewer (conditioned on lining the existing sewer mains and manholes) provided the location does not interfere with the ultimate 3 roadway/building alignments. 4 Where a sewer main exists in the current Harrington Ave NE alignment that will become 5 the new park it will be retained; the City will eliminate manholes where needed and where 6 feasible. The park connection is likely to occur at NE 10th St, or at the west end, where new private development may be able to shorten the existing sewer to keep it within the 7 roadway. Where the section of Glenwood Avenue NE reconnects with Harrington Avenue 8 NE the sewer main will need to be rerouted. 9 Approved plans indicate the Library will connect to the existing sewer in NE 10th Street. 10 B. Fire and Police. Police and Fire Prevention staff indicated that sufficient resources exist to 11 furnish services to the proposed development; if the applicant provides Code required 12 improvements and fees. Impact fees will be discussed in detail as part of the Site Plan 13 Review for each phase and assessed at the time of building permit application. 14 C. Drainage. As with water and sewer, drainage issues related to the individual phases and 15 improvements will be evaluated at the time of each separate site plan approval. However, the regional stormwater facility will be constructed in advance of the future park. The 16 estimated time for the stormwater facility completion is June 30, 2015. The regional 17 stormwater facility in Sunset Park will address flow control for Sunset Blvd NE/SR 900 roadway water quality treatment. The regional facility in the Park is designed for SR 900 18 and is not designed to receive any stormwater from the Master Plan area, and per the grant 19 funding, this site cannot be used for mitigation. 20 D. Parks/Open Space. The proposed development will impact the Parks and Recreation 21 system. These impacts will be mitigated by payment of the Parks Impact Fee for each multi-family unit. The Applicant is a new 3.2 acre park. Sunset Park has been increased in 22 size compared to prior conceptual plans studied in the FEIS, April 2011. Proposed park 23 components include a performance space, a child-friendly water feature, play area, picnic area, restroom building, fitness equipment, walking loop, integration of art, passive open 24 space, plazas, and rain gardens. 25 Both the park and the regional storm water facility require maintenance access and 26 load/unload areas. The maintenance access and load/unload zone will be located on the SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 8 I north side of the future park along (extended) NE 10th St. An internal walkway system 2 will be incorporated into the park however a perimeter park sidewalk will not be included. 3 Common open space will be provided by the individual developments and review as part 4 of the site plan review process for each development. Common use spaces could have views to the west towards Lake Washington and the Olympic Mountains for all residents 5 in proposed 5-6 story buildings. Private open space would most likely be provided through 6 private decks or small yards. 7 E. Transportation. Traffic impacts are adequately mitigated by the proposal. Level of service g standards will not be reduced below adopted levels for the proposal and traffic impact fees 9 will be assessed to pay for proportionate share transportation system impacts. 10 A proposed loop road along Sunset Lane NE will encircle the proposed park. Along the library and mixed-use building space, the lane could be specially paved and serve as a 11 plaza for special events. The width of this roadway is 49 feet. Each phase will be 12 responsible for their proportionate share of frontage improvements (RMC 4-6-060). The City is considering a SAD/LID for the improvement of the Sunset Lane NE loop13 depending on the timing of funding and construction for each individual phase. 14 15 The Sunset Area "green connections" would be implemented per the Sunset Area Surface Water Master Plan. One of these facilities is currently under construction on Harrington 16 Avenue NE. The City is considering street reclassifications and two new street sections for 17 roads that have 60-foot rights of way presently (Staff Report Exhibit 12): Green Collector and Neighborhood Collector. The 60 foot right of way is consistent with the "Green 18 Connections" cross section in the Sunset Area Surface Water Master Plan (Staff Report 19 Exhibit 14). However, the Green Connections can only be implemented in some locations and therefore a 60 foot cross-section for a Neighborhood Collector is also proposed. 20 21 Traffic impact fees for the individual phases will be reviewed at the time of detailed Site Plan Review for each phase would be based on square footage of the building (not 22 including parking garage) and the number of residential units. Fees will be assessed at the 23 time of building permit application. 24 The transportation analysis in the NEPA Reevaluation and SEPA Addendum indicated 25 relatively little difference between the revised Master Plan and previously reviewed 26 alternatives in terms of traffic (Staff Report Exhibit 2). SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 9 1 F. Schools. The assessment of School Impacts and fees will occur during the individual site 2 plan review phase of each proposed improvement. The project will replace some existing public housing units. School impact fees will be assessed only on net new units. 3 4 G. Parking. Compliance with parking standards will be reviewed during specific Site Plan Reviews for each phase. In general, the majority of parking spaces for the residential 5 components will be accommodated primarily in below grade and partially below grade 6 parking levels. Most of the proposed parking counts for individual sites are within the allowable range determined by RMC 4-4-080, except for Site 9/10, which needs an 7 additional 6 parking spaces to meet the required minimum number of parking spaces. 8 However, because the other sites propose parking spaces well over the required minimum number, there could be adequate parking for the Master Site Plan as a whole. A Joint 9 Parking Agreement could be developed prior to future site plan approval addressing any 10 shared parking arrangements, provided parking is within 750 feet of the intended site 11 RMC 4-4-080(E)(3)). 12 H. Bicycle Stalls. Required bicycle parking will be addressed during site plan review for the 13 individual phases. 14 1. Vehicular Access and Internal Circulation. The Master Plan proposes a loop road system 15 that creates a more logical and seamless road pattern than exists today. Pedestrian connections from the street to the buildings will be provided. A complete streets vision 16 has been proposed for the area and would serve to guide improvements to streets within 17 the area. A condition of approval will require all phases included in the Master Site Plan to comply with the Sunset Area Street Classification Map (Staff Report Exhibit 12). 18 19 J. Pedestrian Circulation. A pedestrian circulation system is proposed throughout the project site which connects all opens space and parking areas spaces. Pedestrian circulation will 20 be addressed for each improvement phase at the time of individual site plan approval. 21 K. Landscaping. Landscaping in public spaces and on building sites will be employed to 22 provide transitions between developments and enhance the overall subarea and individual 23 projects' appearance. This topic will be more specifically reviewed during Site Plan Review for each phase. 24 25 L. Refuse Enclosure. Compliance with refuse and recycle standards will be reviewed during specific Site Plan Reviews for each phase. 26 SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 10 1 M. Building Facade Modulation. The individual proposals will include a variety of building 2 articulations and modulations in order to break down the scale and massing of the structures. 3 4 5. Adverse Impacts. The NEPA/SEPA Final Environmental Impact Statement (FEIS) was issued on April 1, 2011. The City completed a Record of Decision (ROD) in accordance with the 5 National Environmental Policy Act (NEPA) in May 2011. The City also completed Planned Action Ordinance (#5610) in accordance with the State Environmental Policy Act (SEPA). The changes to 6 the development proposal to add more units and height and to address street standards require a NEPA Reevaluation, pursuant to Section 58.47 of US Department of Housing and Urban7 Development's (HUD's) NEPA regulations, demonstrating that the original conclusions of the FEIS 8 remain valid. SEPA also provides a process, using an Addendum to the prior FEIS where new information or analysis does not substantially change prior conclusions about impacts (WAC 197-11- 9 706). A Reevaluation, consistent with applicable National Environmental Policy Act (NEPA) regulations and a SEPA addendum, was prepared to evaluate the proposed changes to the Master Site 10 Plan. The Reevaluation and Addendum (December 8, 2014) concluded there are no new or different 11 impacts resulting from the change and the conclusions of the FEIS are still valid. 12 Beyond those impacts contemplated in the FEIS, ROD, Planned Action Ordinance and NEPA Reevaluation and SEPA Addendum, there are no additional significant adverse impacts associated 13 with the project. Few adverse impacts related to the Master Site Plan revision are anticipated. 14 Adequate infrastructure serves the site as determined in Finding of Fact No. 4. There are no critical areas on site. Impacts are more specifically addressed as follows: 15 A. Increased Density. Many sites in the Sunset Terrace Redevelopment Area propose higher 16 densities above the maximum density currently allowed in their associated zone. Viewed 17 in context of the overall Sunset Terrace Site, which since 2011 has been planned comprehensively as a coordinated mixed use redevelopment project with park amenities, 18 the density would equal about 65 dwelling units per acre (du/acre), less than the 80 du/acre maximum allowed in the Center Village zone. 19 Site D is proposed for 106.8 du/acre, well above the maximum density allowed in the CV20 zone. Colpitts Buildings A (118.2 du/acre), B (166.0 du/acre), and C (148.3 due/acre) are 21 each proposed to exceed the 80 du/acre determined by the size of their individual sites. 22 Staff suggest given the Public Park will not be developed with residential units there are opportunities to transfer underutilized density from the park to the proposed Colpitts 23 Buildings A, B, and C. The City has determined a density transfer agreement would be the 24 most appropriate mechanism to transfer the unused density from the park to the redevelopment sites. 25 City Staff have been working with Colpitts in order to develop a methodology and 26 framework for the needed density transfer including the cost per additional unit and how SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 11 I the funds obtained will be allocated. A condition of approval will require the City and 2 Colpitts to execute a Development/Density Transfer Agreement prior to detailed Site Plan Review approval for any phase of development which intends to utilize unused residential 3 density from the proposed park acreage. 4 The RHA Sunset Terrace Apartments/Site D would also exceed the density determined by the size of its anticipated lot acreage. However, RHA Sunset Terrace Apartments would 5 be likely be utilizing unused density from other RHA owned properties (Sunset Court 6 Park, Sunset Park East PIHA). Therefore a density transfer agreement is not needed in this case. 7 B. Increased Height. The Master Site Plan would introduce building heights of 5-6 stories 8 along Sunset Blvd NE and along the south portion of the Sunset Lane NE loop, which 9 would exceed the current maximum height allowed by zoning (Staff Report Exhibit 15). According to the Staff Report, the requested building height limits are consistent with the 10 Sunset Terrace Redevelopment Plan. As proposed, Colpitts Buildings A, B, C (Sites H, I, J) and the Sunset Terrace Apartments (Site D) are inconsistent with maximum height 11 limits of the CV zone, provided only residential uses are proposed. Site D would have 12 heights greater than existing development to the west. The height variance under the conditional use permit was requested in order to allow for a larger Sunset Park while still 13 creating viable developments. There is capacity to add commercial uses in the Master Plan should future applicants so choose. Should the proposals be revised to include commercial 14 uses in some cases no height modification would be needed. 15 The proposed park space would provide a substantial amenity to area residents and reduce 16 the overall visual impression of height and bulk from viewers located further northward of the loop road. For park users, who would be closer to the proposed buildings, increased 17 height could create a perception for park users of being surrounded by buildings looming over them, depending on design treatments. Also, there would be increased height and 18 bulk from the perspective of pedestrians on Sunset Blvd NE. Thus small adjustments to 19 reduce height and bulk related to the increased height and intensity of the structures would reduce impacts. Current city design standards address building modulation and roofline 20 variation and are recommended for application in the NEPA Reevaluation/SEPA Addendum(Exhibit 2). 21 22 Increased height at the southern end of the Redevelopment Area would have the potential to slightly increase the length of shadows cast on the interior park to the north. However, 23 reconfiguration of the park to increase its size as part of the updated Master Site Plan process would ameliorate this to some degree, and the application of design standards 24 would further reduce shading impacts from increased building heights. 25 The "rim" of the Sunset Terrace Redevelopment area is particularly well suited to the 26 greater density/height proposed as it is immediately adjacent to Sunset Blvd NE, a major SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 12 I arterial and state highway capable of accommodating the traffic generated by the proposed 2 project. 3 The proposed development would be among the taller developments in the vicinity until such time as other properties will be redeveloped to meet the more intensive vision of the 4 CV zone. The proposed project is compatible with the scale and character of the existing and planned neighborhood. When the proposed height is considered in the context of the 5 entire redevelopment plan area, the average height proposed for development is well 6 below 60-feet3. The additional height allows for the achievement of the proposed units and reflects the greater size of the park and redistribution of units to maximize the park site. 7 Sunset Terrace has been identified as an area where it is desirable to develop residential uses to a density greater than currently exists, which requires either less public open space 8 or higher buildings. 9 Compliance with the height standards for all other structures will be reviewed during 10 specific Site Plan Reviews for each phase. 11 C. Increased Lot Coverage. As with the increased density and height, the proposal 12 collectively meets the lot coverage requirements. However, Sites D, H/K, I and J exceed the standard individually. If these lots are aggregated with the increased park acreage, lot 13 coverage requirements are met. Staff notes this is consistent with the overall Master Plan approach. The remaining lots all appear to be able to meet lot coverage requirements 14 through the use of structured parking, a topic which will be reassessed during individual 15 site plan review as each phase progresses. 16 D. Reduced Setbacks. The 2011 SR 900 Conceptual Plan was designed to account for reduced setbacks along Sunset Lane NE. The plan assumes no front yard setbacks in this 17 location. Lot depths are 125 feet east of Harrington Avenue NE consistent with the VEER site plan for Lots 9/10, and 130 feet west of Harrington Avenue NE. In all areas besides 18 along the redesigned Sunset Lane NE (SR 900), lot depths are sufficient to allow for 19 sufficient depths of buildings with underbuilding parking and account for odd geometries. This being said,there should be room for a small setback from Sunset Lane NE. 20 Compliance with setback standards will be reviewed during specific Site Plan Reviews for 21 all other properties. 22 E. Privacy and Noise. Noise impacts are adequately mitigated. Staff anticipates most of the 23 noise impacts would occur during the construction phase of the project. The Master Site Plan includes an arrangement of buildings around the Sunset Park to reduce noise. 24 25 3 The maximum height allowable without a hearing examiner approved conditional use permit is 50 feet(RMC 4-2- 26 120(C)(16)). SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 13 I Conclusions of Law 2 3 1. Authority. Master Site Plan Approvals for the overall plan and Conditional Use Permit approvals are each Type III decisions determined by the hearing examiner (RMC 4-8-080(G)). The 4 aforementioned permits have been consolidated. RMC 4-8-080(C)(2) requires consolidated permits to 5 each be processed under "the highest-number procedure." As Type III applications, RMC 4-8-080(G) grants the Examiner with the authority to hold a hearing and issue a final decision on them, subject to 6 closed record appeal to the City Council. 7 2. Zoning/Comprehensive Plan Designations. The property is zoned Center Village (CV) and 8 Residential-14 (R-14). The Comprehensive Plan designation is Center Village. 9 3. Review Criteria. Master Site Plan Review is an optional process in the CV and R-14 zones RMC 4-9-200(B)(1)). To accommodate the localized change in density, the City has requested10 Master Site Plan review. The City has requested a Conditional Use Permit to increase the height limit 11 and lot coverage requirements and reduce setbacks in the areas proposed for additional units. The City has also requested a change in the vesting timeline. Master Site Plan review standards are12 governed by RMC 4-9-200(E)(3). Conditional Use Permits are governed by RMC 4-9-030. All 13 applicable criteria are quoted below in italics and applied through corresponding conclusions of law. 14 Master Site Plan 15 RMC 4-9-200(E)(3): Criteria: The Administrator or designee must find a proposed project to be in 16 compliance with the following: 17 a. Compliance and Consistency: Conformance with plans, policies, regulations and approvals, 18 including: 19 i. Comprehensive Plan: The Comprehensive Plan, its elements, goals, objectives, and policies, especially those of the applicable land use designation; the Community Design 20 Element; and any applicable adopted Neighborhood Plan; 21 ii. Applicable land use regulations; 22 iii. Relevant Planned Action Ordinance and Development Agreements; and 23 iv. Design Regulations: Intent and guidelines of the design regulations located in RMC 4- 24 3-100. 25 4.The proposal is consistent with applicable comprehensive plan policies, City of Renton zoning 26 1 regulations and design guidelines and the Sunset Planned Action area (Staff Report Exhibit 10) as SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 14 I outlined in Findings 20(a)-(1) of the staff report, which is adopted by this reference as if set forth in 2 full, including the findings and conclusions. 3 RMC 4-9-200(E)(3)(b): Off-Site Impacts: Mitigation of impacts to surrounding properties and uses, including: 4 5 i. Structures: Restricting overscale structures and overconcentration of development on a particular portion of the site; 6 ii. Circulation: Providing desirable transitions and linkages between uses, streets, 7 walkways and adjacent properties; 8 iii. Loading and Storage Areas: Locating, designing and screening storage areas, 9 utilities, rooftop equipment, loading areas, and refuse and recyclables to minimize views 10 from surrounding properties; 11 iv. Views: Recognizing the public benefit and desirability of maintaining visual accessibility to attractive natural features; 12 v. Landscaping: Using landscaping to provide transitions between development and 13 surrounding properties to reduce noise and glare, maintain privacy, and generally 14 enhance the appearance of the project; and 15 vi. Lighting: Designing and/or placing exterior lighting and glazing in order to avoid 16 excessive brightness or glare to adjacent properties and streets. 17 5. The design as revised would mass more density in one portion of the subarea than in others and increase the bulk of structures in that area. However, as determined in Finding of Fact No. 5, the 18 increased density and scale of the structures are appropriate along Sunset Boulevard NE because of the heavy regional traffic in that area. The buildings will be modulated and designed to provide 19 relief to pedestrians walking near them. The most important offset, though, is the increased size of 20 the public park afforded by the proposed building massing and density. The design also allows for improved vehicular circulation throughout the entire subarea by creating a new loop road. This 21 decision is a Master Plan Review and therefore is meant to be conceptual in nature. It represents a decade long development of multiple phases of mixed use, mixed income development by public 22 and private entities. As such, issues related to internal circulation, loading and storage areas, landscaping and lighting will be dealt with during the individual site plan review stages as each23phaseprogresses. There are presently no views of attractive natural features. As proposed, the 24 impacts to surrounding properties created by the revised design are mitigated. 25 26 SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 15 1 2 RMC 4-9-200(E)(3)(c): On-Site Impacts:Mitigation of impacts to the site, including: 3 i. Structure Placement: Provisions for privacy and noise reduction by building placement, 4 spacing and orientation; 5 ii. Structure Scale: Consideration of the scale ofproposed structures in relation to natural characteristics, views and vistas, site amenities, sunlight, prevailing winds, and pedestrian6 and vehicle needs; 7 iii. Natural Features: Protection of the natural landscape by retaining existing vegetation 8 and soils, using topography to reduce undue cutting and filling, and limiting impervious 9 surfaces; and 10 iv. Landscaping: Use of landscaping to soften the appearance of parking areas, to provide shade and privacy where needed, to define and enhance open spaces, and generally to 11 enhance the appearance of the project. Landscaping also includes the design and protection 12 of planting areas so that they are less susceptible to damage from vehicles or pedestrian movements. 13 6. As determined in Finding of Fact No. 5, the arrangement of buildings around Sunset Park will 14 block noise from SR 900. There is nothing in the record to reasonably suggest that the scale, spacing 15 and orientation of the project could be modified to provide for more privacy and noise reduction without unreasonably interfering with the objectives of the facility or creating a detrimental impact 16 to the proposed park. The scale of the facility will not create any adverse impacts as discussed and is compatible with vehicle and pedestrian circulation as determined in Finding of Fact No. 5. In 17 addition, there is nothing in the record to reasonably suggest that the scale of the project is 18 incompatible with sunlight, prevailing winds or natural characteristics. Impervious surfaces are significantly less than those authorized by applicable zoning regulations and are within the range 19 anticipated in the FEIS for the original Master Plan. 20 RMC 4-9-200(E)(3)(d): Access and Circulation: Safe and efficient access and circulation for all 21 users, including: 22 i. Location and Consolidation: Providing access points on side streets or frontage streets rather than directly onto arterial streets and consolidation of ingress and egress points on the 23 site and, when feasible, with adjacent properties; 24 ii. Internal Circulation: Promoting safety and efficiency of the internal circulation system, 25 including the location, design and dimensions of vehicular and pedestrian access points, 26 drives,parking, turnarounds, walkways, bikeways, and emergency access ways; SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 16 1 2 iii. Loading and Delivery: Separating loading and delivery areas from parking and 3 pedestrian areas; 4 iv. Transit and Bicycles:Providing transit, carpools and bicycle facilities and access; and 5 v. Pedestrians: Providing safe and attractive pedestrian connections between parking areas, 6 buildings,public sidewalks and adjacent properties. 7 7. The proposal provides for adequate access and circulation as required by the criterion above for the reasons identified in Finding of Fact No. 4(I) and (J). 8 RMC 4-9-200(E)(3)(e): Open Space: Incorporating open spaces to serve as distinctive project 9 focal points and to provide adequate areas for passive and active recreation by the occupants/users 10 of the site. 11 8. The proposal provides for open space that serves as distinctive project focal points and also provides for recreation as determined in Finding of Fact No. 4(N). A primary feature of the revised 12 proposal is an expanded public park which will serve as a visual and social focal point for the 13 neighborhood. 14 RMC 4-9-200(E)(3)(f): Views and Public Access: When possible, providing view corridors to 15 shorelines and Mt. Rainier, and incorporating public access to shorelines. 16 9. There are no view corridors to shorelines or Mt. Rainier affected by the proposal. 17 RMC 4-9-200(E)(3)(g): Natural Systems: Arranging project elements to protect existing natural 18 systems where applicable. 19 10. As noted in Finding of Fact No. 5, there are no critical areas on site. As determined in Finding of Fact No. 4, the drainage system is designed to accommodate pedestrian friendly greenscape and 20 sidewalks while improving the existing regional stormwater quality. 21 RMC 4-9-200(E)(3)(h): Services and Infrastructure: Making available public services and 22 facilities to accommodate the proposed use. 23 11. The project is served by adequate services and facilities as determined in Finding of Fact No. 4. 24 25 RMC 4-9-200(E)(3)(i): Phasing: Including a detailed sequencing plan with development phases and estimated time frames,for phased projects. 26 SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 17 1 2 12. The Master Plan includes a detailed sequencing plan for development phases over a ten year 3 timeframe. Finding 20L of the Staff Report is adopted here by reference as if set forth in full. 4 Conditional Use 5 The Administrator or designee or the Hearing Examiner shall consider, as applicable, the following 6 factors for all applications: 7 RMC 4-9-030(C)(1): Consistency with Plans and Regulations: The proposed use shall be compatible with the general goals, objectives, policies and standards of the Comprehensive Plan, the 8 zoning regulations and any other plans,programs, maps or ordinances of the City of Renton. 9 13. The Master Plan promotes a mixed use redevelopment with open space and civic amenities. 10 The Master Plan would advance the City's Center Village concept in the Comprehensive Plan and zoning code. It would serve as an incentive for other redevelopment opportunities near the study area. 11 Anticipated growth would help the City meet its 2031 housing and employment targets. It would also 12 serve to fulfill the Sunset Area Community Investment Strategy. The proposal is consistent with applicable comprehensive plan policies, City of Renton zoning regulations and design guidelines and 13 the Sunset Planned Action area (Staff Report Exhibit 10) as outlined in Findings 20(a)-(1) of the staff report, which is adopted by this reference as if set forth in full, including the findings and 14 conclusions. 15 RMC 4-9-030(C)(2): Appropriate Location: The proposed location shall not result in the 16 detrimental overconcentration of a particular use within the City or within the immediate area of the 17 proposed use. The proposed location shall be suited for the proposed use. 14. As described above in Finding of Fact No. 5, the proposed location is suitable for the proposed18 use. The overall Sunset Terrace Site has been planned comprehensively as a coordinated mixed use 19 redevelopment project with park amenities at an overall density that is less than the allowed maximum in the CV zone while providing public amenities including affordable housing, a new 20 library and a public park. Given these factors the criterion is met. 21 RMC 4-9-030(C)(3): Effect on Adjacent Properties: The proposed use at the proposed location 22 shall not result in substantial or undue adverse effects on adjacent property. 23 15. As determined in Finding of Fact No. 5 there are no adverse impacts associated with the 24 proposal, so it will not result in substantial or undue adverse effects on adjacent property. The proposed development would be among the taller developments in the vicinity, though it is essentially 25 the first coordinated development to implement the more intensive vision of the CV zone. The 26 proposed project is compatible with the scale and character of the existing and planned neighborhood. SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 18 1 2 RMC 4-9-030(C)(4): Compatibility: The proposed use shall be compatible with the scale and 3 character of the neighborhood. 4 16. As determined in Finding of Fact No. 5, the proposed use is compatible with the scale and character of the neighborhood since it does not involve any significant adverse aesthetic impacts and 5 allows for the expansion of the proposed Sunset Park, creates a new loop road to improve access and creates a gateway along SR 900. 6 7 RMC 4-9-030(C)(5): Parking:Adequate parking is, or will be made, available. 8 17. As noted in Finding of Fact No. 4, most parking is proposed to be in structures. Parking will be reviewed during the phased build out at the time of each individual phase's site plan review. At 9 this stage, the overall project appears to provide adequate parking. 10 RMC 4-9-030(C)(6): Traffic: The use shall ensure safe movement for vehicles and pedestrians and 11 shall mitigate potential effects on the surrounding area. 12 18. As determined in Finding of Fact No. 4, the local roadway network will be improved through 13 the redesigned Sunset Boulevard, the new loop road and the reconstructed Harrington Road. The project will not have a significant impact on the general traffic in the vicinity and provides for 14 adequate and safe pedestrian circulation. The criterion is met. 15 RMC 4-9-030(C)(7): Noise, Light and Glare: Potential noise, light and glare impacts from the 16 proposed use shall be evaluated and mitigated. 17 19. As determined in Finding of Fact No. 5, noise and light impacts will be addressed during 18 individual site plan reviews for each implementing project. Lighting will comply with City regulations which require lights to be directed inwards and prohibited light trespass. The building 19 design along Sunset Boulevard should shield park users from regional traffic noise from SR 900. 20 RMC 4-9-030(C)(8): Landscaping: Landscaping shall be provided in all areas not occupied by 21 buildings, paving, or critical areas. Additional landscaping may be required to buffer adjacent properties from potentially adverse effects of the proposed use. 22 20. The criterion is met for the reasons discussed in Finding of Fact No. 4K under aesthetic 23 impacts. 24 25 26 SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 19 I Time Limits 2 RMC 4-8-100(T): Expiration of Large Scale or Phased Projects: For large scale or phased 3 development projects, the Examiner may at the time of approval or recommendation set forth time limits for expiration which exceed those prescribed in this Section for such extended time limits as 4 are justified by the record of the action. 5 21. The applicants have requested an extended expiration timeline for the project because of its 6 scale and complexity. They have also indicated much of the public infrastructure and development is grant dependent. The applicants have requested a 10 year expiration limit. This request is granted. 7 8 DECISION 9 The Master Site Plan and Conditional Use Permit for the Renton Sunset Redevelopment Master Site 10 Plan, File No. LUA 14-001475, SA-M, CU-P as depicted in Exhibit 3 of the Staff Report, are 11 approved subject to the following conditions. 12 1. A Development/Density Transfer Agreement shall be executed by the City and Colpitts prior to detailed Site Plan Review approval for any phase of development which intends to utilize 13 unused residential density from the proposed park acreage. 14 2. All phases included in the Master Site Plan shall comply with the Sunset Area Street 15 Classification Map, (Staff Report Exhibit 12). Conceptual frontage improvements shall be submitted at the time of Site Plan Review for each phase and are subject to approval by the 16 Current Planning Project Manager and Plan Reviewer. 17 3. Prior to beginning construction, each individual project phase or improvement shall provide 18 information to surrounding property owners about timelines, extent of construction, and contact information. 19 4. This decision is effective until January 14,2025. 20 21 DATED this 10 day of January,2015. 22 23 Emily Terr 24 City of Renton Hearing Examiner Pro Tem 25 26 SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION,AND LOT LINE ADJUSTMENT-20 1 2 Appeal Right and Valuation Notices 3 RMC 4-8-080 provides that the final decision of the hearing examiner is subject to appeal to the Renton City Council. RMC 4-8-110(E)(14) requires appeals of the hearing examiner's decision to 4 be filed within fourteen (14) calendar days from the date of the hearing examiner's decision. A request for reconsideration to the hearing examiner may also be filed within this 14 day appeal5periodasidentifiedinRMC4-8-110(E)(13) and RMC 4-8-100(G)(9). A new fourteen (14) day 6 appeal period shall commence upon the issuance of the reconsideration. Additional information regarding the appeal process may be obtained from the City Clerk's Office, Renton City Hall — 7th 7 floor, (425) 430-6510. 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 SITE PLAN, CRITICAL AREAS EXEMPTION, STREET MODIFICATION, AND LOT LINE ADJUSTMENT- 21 SUNSET AREA COMMUNITY PLANNED ACTION FINAL NEPA/SEPA ENVIRONMENTAL IMPACT STATEMENT • VOLUME 1 • APRIL 2011 Issued by: City of Renton NEPA Responsible Entity and SEPA Lead Agency Prepared in partnership with: Renton Housing AuthorityRenton Housing Authority 1 Sunset Terrace Master Site Plan Amendment August 2019 | Project Narrative Master Site Plan Amendment Proposal The City of Renton, along with the Renton Housing Authority (RHA), and other public, private, and nonprofit agencies and developers, is redeveloping the Sunset Terrace public housing community plus some peripheral sites that have been master planned for redevelopment along with Sunset Terrace for a total of about 12.7 acres. See Exhibit 1. The Master Site Plan envisions a mixed-use, mixed-income community with park and library and other civic and commercial uses. Mixed-use sites will have both market rate and affordable rental housing in multi-story, multi-family townhomes and apartments, along with commercial and retail space. The Master Site Plan is located within the Renton Sunset neighborhood that has been included in the Renton Comprehensive Plan as a center for new housing, commercial, recreation, education, and other uses. See Exhibit 2. The Master Site Plan is the core of redevelopment areas but is part of a larger suite of neighborhood improvements. See Exhibit 3, illustrating the Sunset Terrace redevelopment area and housing replacement sites. See Exhibit 4 and Exhibit 5 identifying the Master Plan sites and other planned projects. In order to meet National Environmental Policy Act (NEPA) and State Environmental Policy Act (SEPA) requirements, the City of Renton issued the Draft Environmental Impact Statement (DEIS) for the City of Renton Sunset Area Community Planned Action on December 17, 2010 and the Final Environmental Impact Statement (FEIS) for the City of Renton Sunset Area Community Planned Action on April 1, 2011.1 The City served as the Responsible Entity (RE) for NEPA compliance, and the lead agency for SEPA compliance. The Sunset Terrace Master Site Plan Area was also the subject of subsequent revaluations/addenda in 2014 and 2016. The Master Site Plan completed in 2014 provides a coordinated plan of development for both the Sunset Terrace and Replacement sites. The 2016 Master Site Plan amendment added properties into the Master Site Plan, and redistributed some dwelling units, but retained the same overall number of units as approved by the 2014 Master Site Plan. See Exhibit 3 for the Sunset Terrace redevelopment area and housing replacement sites. In 2019, RHA2 is proposing an amended Master Site Plan that would: 1 CH2MHill and ICF International. 2011. Sunset Area Community Planned Action NEPA/SEPA Environmental Impact Statement. Final. April. (ICF 00593.10.) Bellevue and Seattle, WA. Prepared for City of Renton and the Renton Housing Authority, Renton, WA. 2 RHA owns Sites C and E. The applicant for Site E is Sunset Oakes LLLP. 2  Shift units between a site on the west (Site C/18: Edmonds Apartments/Homestead Willow Crest Townhomes) to a site in the north of the Master Site Plan area (Site E/14,16/17: Sunset Park West Townhomes 2014/Harrington Park 2016/Sunset Oaks 2019). A 2019 NEPA/SEPA Reevaluation has been prepared to support the minor Master Site Plan amendment. The 2019 reallocation proposal would not add housing units in the Master Site Plan area or in the Sunset Area neighborhood. However, consistent with the flexibility allowed by the adopted Master Site Plan, some units would be redistributed. As amended, development in the Master Site Plan area would meet City standards for density, height, setbacks, transportation levels of service, connection to utilities, and would be subject to City parking codes, including procedures for modifying applicable standards. The amended Master Site Plan would be consistent with RMC Title IV. See below regarding minor Master Site Plan Amendment criteria. The 2019 NEPA/SEPA Reevaluation also assesses the future removal of a site from the Master Site Plan boundaries (Site G/11 known previously as the Sunset Park East (Piha) Townhomes & Apartments 2014/Suncrest Homes 2016/Solera 2019). The site would remain within the Sunset Area Community neighborhood. This Master Site Plan boundary amendment proposal is evaluated for potential implementation at a later date. It would require a Major Site Plan amendment and Planned Action Ordinance (PAO) amendment when accomplished. The 2019 Reevaluation identifies implications of the site’s future removal should the City or RHA desire that amendment. Also, the SEPA PAO would be amended in the future to include the revised Master Site Plan concept should the Solera site be removed. The total development levels and mitigation measures in the PAO remain unchanged. 3 Exhibit 1. Sunset Terrace Master Site Plan 2016 Source: Mithun, City of Renton 2016 4 Exhibit 2. Planned Action Area: 2011 Source: CH2MHill and ICF International, 2011; BERK, 2016. 5 Exhibit 3. Renton Sunset Terrace Redevelopment Area and Swap Sites: 2016 Source: CH2MHill and ICF International, 2011; BERK, 2016. 6 Exhibit 4. Lettered Master Plan Sites # - Master Plan Sites /// - Sunset Terrace Public Housing Boundaries 7 Exhibit 5. Revitalization Projects: 2019 8 Minor Modification Criteria The following discussion addresses compliance with criteria for a minor Modification of the prior 2014 Master Site Plan, amended in 2016. 4-9-200.H. MODIFICATIONS TO AN APPROVED MASTER PLAN OR SITE PLAN: 1. Major Modifications: Major modifications to an approved master plan or site plan require a new application. 2. Minor Modifications: Minor modifications may be permitted by administrative determination. To be considered a minor modification, the amendment must not: a. Involve more than a ten percent (10%) increase in area or scale of the development in the approved plan; or Discussion: There is no increase in the scale of development. Building heights are consistent with what was evaluated in 2016. Total dwelling units are consistent with the 2014 Master Site Plan as amended in 2016. b. Have a significantly greater impact on the environment and/or public facilities than the approved plan; or The 2019 NEPA/SEPA Reevaluation shows similar impacts and mitigation measures as the 2011 Environmental Impact Statement, and the 2014 and 2016 Reevaluations. There is no change in the applicable Planned Action Ordinance mitigation measures. c. Change the boundaries of the originally approved plan. The current application does not propose changes to the boundaries of the Master Site Plan. In the future, the City or RHA may propose the removal of Site G/11 (also known as Solera). The 2019 Reevaluation addresses the implications of this change, which show no change to overall goals for the neighborhood or the environmental review. Attachments  2014 Master Site Plan Approval  2016 Master Site Plan Amendment KEY RESIDENTIAL MIXED-USE COMMUNITY ——SITEAREA 0’100’200’400’ Sunset Terrace Master Site Plan RENTON SUNSET AREA MSP EXHIBIT 9 CITY OF RENTON, WASHINGTON ORDINANCE NO. 5813 AN ORDINANCE OF THE CITY OF RENTON, WASHINGTON, AMENDING ORDINANCE NOS. 5610 AND 5740, ADDING FIVE PARCELS AND REDISTRIBUTING, BUT NOT INCREASING, THE TOTAL NUMBER OF HOUSING UNITS IN THE SUNSET TERRACE REDEVELOPMENT AREA, AND REVISING A PLANNED ACTION DESIGNATED FOR THE SUNSET AREA PURSUANT TO THE STATE ENVIRONMENTAL POLICY ACT(SEPA). THE CITY COUNCIL OF THE CITY OF RENTON, WASHINGTON, DOES ORDAIN AS FOLLOWS: SECTION I. Findin s. The Council finds as follows: A. The City is subject to the requirements of the Growth Management Act, RCW 36.70A ("GMA") and is located within an Urban Growth Area; B. The City has adopted a Comprehensive Plan complying with the GMA, and has amended the Comprehensive Plan to address transportation improvements and capital facilities specific to the Sunset Area; C. The City has adopted a Community Investment Strategy, development regulations, and design guidelines specific to the Sunset Area, as designated in Attachment A, which will guide growth and revitalization of the area, including the Sunset Terrace public housing redevelopment area identified in Attachment C; D. The City has prepared an Environmental Impact Statement (EIS) for the Sunset Area, supplemented by addenda, that addresses the probable significant environmental impacts associated with the location, type, and amount of development anticipated in the Planned Action area; 1 ORDINANCE N0. 5813 E.The mitigation measures identified in the Planned Action EIS, and attached to this ordinance as Attachment B, together with adopted City development regulations, will adequately mitigate the probable significant environmental impacts from development within the Planned Action area; F.Future development projects in and around the Planned Action Area will protect the environment, benefit the public and enhance economic development; G. The public has meaningfully participated in the proposed Planned Action, during comment periods, community meetings, and hearings, during and after the preparation of the EIS, and the City has modified the proposal or mitigation measures in response to some of the suggestions; H. The Sunset Area Planned Action is not an essential public facility as defined by RCW 36.70A.200(1); I.The Planned Action Area applies to a defined subarea of the City boundaries illustrated in Attachment A; J.Public services and facilities are adequate to serve the proposed Planned Action area; K. The City adopted a Planned Action Ordinance 5610 on June 13, 2011, and subsequently replaced it with Ordinance 5740 on December 8, 2014 to reflect preparation of a Master Plan for the Renton Sunset Terrace redevelopment area within the larger Planned Action Area and to reflect integration of a Reevaluation Alternative in 2014; L.A revised master plan for the Sunset Terrace redevelopment area was submitted to the City on May 27, 2016, which amends the 2014 Reevaluation Alternative by shifting the 2 ORDINANCE N0. 5813 location of planned dwellings and master plan territory to include five additional parcels, and redistributing but not altering the total number of dwellings studied or boundaries of the designated Planned Action Area in Attachment A; M. A NEPA Reevaluation, dated June 2016, pursuant to the National Environmental Policy Act (NEPA), as authorized by U.S. Department of Housing and Urban Development regulations, and an EIS addendum pursuant to SEPA were prepared to consider the environmental effects of the revised Sunset Terrace master plan; N. The City held a community meeting consistent with RCW 43.21C.440 on June 6, 2016; and 0. The City Council held a public hearing on July 11, 2016 regarding new amendments to the Planned Action applicable to the Sunset Area in order to integrate the Reevaluation Alternative, outlined in the NEPA Reevaluation and SEPA Addendum. SECTION II. Procedures and Criteria for Evaluatin and Determinin Proiects as Planned Actions. A. Planned Action Area. The Planned Action designation shall apply to the area shown in Attachment A. B.Environmental Document. A Planned Action determination for a site-specific implementing project application shall be based on the environmental analysis contained in the Draft EIS issued by the City on December 17, 2010, and the Final EIS published on April 1, 2011, the NEPA reevaluation/SEPA addendum published on December 12, 2014, and the 2016 NEPA reevaluation/SEPA addendum published on June 10, 2016. The Planned Action EIS shall consist of the Draft EIS, Final EIS, and the 2016 NEPA reevaluation/SEPA addendum. The mitigation 3 ORDINANCE N0. 5813 measures contained in Attachment B are based upon the findings of the above-mentioned environmental documents and shall, along with adopted City regulations, provide the framework for the City's imposition of appropriate conditions on qualifying Planned Action projects. C.Planned Action Designated. Land uses and activities described in the Planned Action EIS, subject to the thresholds described in subsection II.D below and the mitigation measures contained in Attachment B, are designated Planned Actions or Planned Action Projects pursuant to RCW 43.21C.031. A development application for a site-specific Planned Action project located within the Sunset Area shall be designated a Planned Action if it meets the criteria set forth in subsection II.D of this ordinance and applicable laws, codes, development regulations and standards of the City. D. Planned Action Qualifications. The following thresholds shall be used to determine if a site-specific development proposed within the Sunset Area is contemplated by the Planned Action and has had its environmental impacts evaluated in the Planned Action EIS: 1) Land Use. a) The following general categories/types of land uses are considered Planned Actions: single family and multi-family residential; schools; parks; community and public facilities; office and conference; retail; entertainment and recreation; services; utilities; and mixed-use development incorporating more than one use category where permitted. b) Individual land uses considered as Planned Actions shall include those uses specifically listed in RMC 4-2-060, Zoning Use Table — Uses Allowed in Zoning 4 ORDINANCE N0. 5813 Designations, as permitted or conditionally permitted in the zoning classifications applied to properties within the Planned Action area provided they are consistent with the general categories/types of land uses in (1)(a). 2) Development Thresholds. a) The following amount of various new land uses are anticipated by the Planned Action: Land Use Development Amount Alternative 3/ FEIS Preferred Alt Reevaluation Alternative Residential I 2,506 units 2,339 units I Schools I 57,010 gross square feet 57,010 gross square feet I I Parks 0.25 -3.2 acres 3 acres I I Office/Service 776,805 gross square feet I 745,810 gross square feet I Retail 476,299 gross square feet I 457,119 gross square feet b) The following infrastructure and utilities are considered planned actions: roadways, water, wastewater, and stormwater facilities identified and studied in the EIS. c) Shifting development amounts between categories of uses may be permitted so long as the total build-out does not exceed the aggregate amount of development and trip generation reviewed in the EIS, and so long as the impacts of that development have been identified in the Planned Action EIS and are mitigated consistent with Attachment B. d) The Renton Sunset Area Master Site Plan is included in Attachment C and is to be used as a conceptual guide to redevelopment in that portion of the 5 ORDINANCE N0. 5813 Planned Action area, together with the land use studied in the NEPA reevaluation/SEPA addendum published on June 10, 2016, and the use allowances of the Renton Municipal Code. e) If future development proposals in the Planned Action area exceed the development thresholds specified in this ordinance, further environmental review may be required pursuant to WAC 197-11-172, Planned actions—Project review. Further, if proposed development would alter the assumptions and analysis in the Planned Action EIS, further environmental review may be required. 3) Transportation -Trip Ran es and Thresholds. Inserted below are the new PM Peak Hour Trips anticipated in the Planned Action area: I Alternative/Period PM Peak Hour Trips* I I 2006 2,082 trips 2030 Alternative 3/ Reevaluation 5,555 trips Alternative I 2030 Preferred Alt 5,386 trips Net increase from 2006-> 2030 Alternative 3,473 trips 3 / Reevaluation Alternative Net increase from 2006-> 2030 Preferred 3,304 trips Alternative all PM peak hour trips with at least one end (origin, destination, or both) in TAZs containing the study area Uses or activities that would exceed the range of maximum trip levels will require additional SEPA review. 4) Chan ed Conditions. Should environmental conditions change significantly from those analyzed in the Planned Action EIS, the City's SEPA Responsible Official may determine that the Planned Action designation is no longer applicable until supplemental environmental review is conducted. 6 ORDINANCE N0. 5813 E.Planned Action Review Criteria. 1) The City's Environmental Review Committee may designate as "planned actions", pursuant to RCW 43.21C.030, Guidelines for stare agencies, local governments -- Statements -- Reports -- Advice — Information, applications that meet all of the following conditions: a) The proposal is located within the Planned Action area identified in Attachment A of this ordinance; b) The proposed uses and activities are consistent with those described in the Planned Action EIS and subsection II.D of this ordinance; c) The proposal is within the Planned Action thresholds and other criteria of subsection II.D of this ordinance; d) The proposal is consistent with the City of Renton Comprehensive Plan and applicable zoning regulations; e) The proposal's probable significant adverse environmental impacts have been identified in the Planned Action EIS; f) The proposal's probable significant adverse environmental impacts have been mitigated by application of the measures identified in Attachment B, and other applicable City regulations, together with any modifications or variances or special permits that may be required; g) The proposal complies with all applicable local, state and/or federal laws and regulations, and the Environmental Review Committee determines that these constitute adequate mitigation; and 7 ORDINANCE N0. 5813 h) The proposal is not an essential public facility as defined by RCW 36.70A.200(1j. 2) The City shall base its decision on review of a SEPA checklist, or an alternative form approved by the Department of Ecology, and review of the application and supporting documentation. 3) A proposal that meets the criteria of this section shall be considered to qualify and be designated as a planned action, consistent with the requirements of RCW 43.21C.030, Guidelines for state agencies, local governments--Statements -- Reports --Advice– Information, WAC 197-11-164, Planned actions—Definition and criteria, and this ordinance. F. Effect of Planned Action. 1) Designation as a planned action project means that a qualifying proposal has been reviewed in accordance with this ordinance and found to be consistent with its development parameters and thresholds, and with the Planned Action EIS's environmental analysis. 2) Upon determination by the City's Environmental Review Committee that the proposal meets the criteria of subsection II.D and qualifies as a Planned Action, the proposal shall not require a SEPA threshold determination, preparation of an EIS, or be subject to further review pursuant to SEPA. G. Planned Action Permit Process. Applications for planned actions shall be reviewed pursuant to the following process: 1) If the project is determined to qualify as a Planned Action, it shall proceed in accordance with the applicable permit review procedures specified in RMC 4-8- 8 ORDINANCE N0. 5813 080.G and 4-9, except that no SEPA threshold determination, EIS or additional SEPA review shall be required. The decision of the Environmental Review Committee regarding qualification as a Planned Action shall be final. 2) Public notice and review for projects that qualify as Planned Actions shall be tied to the underlying permit. The review process for the underlying permit shall be as provided in RMC 4-8-080.G, Land Use Permit Procedures, and RMC 4-9 as modified by RCW 43.21C.440(3)(b). If notice, in addition to the requirements of RCW 43.21C.440(3)(b), is otherwise required for the underlying permit, the notice shall state that the project has qualified as a Planned Action. If notice is not otherwise required for the underlying permit, no special notice is required by this ordinance. 3) If a project is determined to not qualify as a Planned Action, the Environmental Review Committee shall so notify the applicant and require a SEPA review procedure consistent with the City's SEPA regulations and the requirements of state law. The notice shall describe the elements of the application that result in failure to qualify as a Planned Action. 4) Projects that fail to qualify as Planned Actions may incorporate or otherwise use relevant elements of the Planned Action EIS, as well as other relevant SEPA documents, to meet their SEPA requirements. The Environmental Review Committee may limit the scope of SEPA review for the non-qualifying project to those issues and environmental impacts not previously addressed in the Planned Action EIS. SECTION III. Monitorin and Review. 9 ORDINANCE N0. 5813 A. The City shall monitor the progress of development in the designated Planned Action area to ensure that it is consistent with the assumptions of this ordinance and the Planned Action EIS regarding the type and amount of development and associated impacts, and with the mitigation measures and improvements planned for the Sunset Area. B. This Planned Action ordinance shall be reviewed no later than five (5) years from its effective date by the Environmental Review Committee to determine the continuing relevance of its assumptions and findings with respect to environmental conditions in the Planned Action area, the impacts of development, and required mitigation measures. Based upon this review, the City may propose amendments to this ordinance and/or may supplement or revise the Planned Action EIS. C. At the following time periods, the City shall evaluate the overall sustainability of the Sunset Area Planned Action area, defined in Attachment A, consistent with Final EIS Appendix A review of Goals and Objectives and LEED-ND qualitative evaluation, or an equivalent approach: 1) At the time of the five (5)-year review in subsection IV.B above. 2) At the time of a NEPA re-evaluation pursuant to 24 CFR Part 58.53, for the Sunset Community Planned Action Area. D. The City shall conduct a Greenroads evaluation or its equivalent at the time the NE Sunset Boulevard design is at the thirty percent (30%) design level and at the sixty percent 60%) design level. E. The City shall review the Potential Sunset Terrace Redevelopment Subarea at the time of the five (5)-year review in subsection III.B in relation to the following evaluation criteria: 10 ORDINANCE N0. 5813 1) Contribution of final conceptual designs to 2030 Regional Vehicle Miles Travelled (VMT) consistent with Final EIS Table 3.2-4, Sunset Terrace Redevelopment Subarea Contribution to Forecast 2030 Regional VMT. 2) Changes in land use and population growth and resulting greenhouse gas emissions of final conceptual designs compared to Tables 3.2-5 and 3.2-6 of the Final EIS, titled respectively Assumed Land Use and Population Growth for Greenhouse Gas Emission Calculations—Potential Sunset Terrace Redevelopment Subarea and Comparison of Greenhouse Gas Emissions—Potential Sunset Terrace Redevelopment Subarea. 3) Change in effective impervious area for Sunset Terrace Redevelopment Subarea compared with Final EIS Preferred Alternative and Alternative 3 which resulted in a decrease of approximately 0.51 acre (11%) to 1.07 acres (23%) compared to existing conditions as provided in Table 7 of the Planned Action ordinance Attachment B. SECTION IV. Conflict. In the event of a conflict between this ordinance or any imposed mitigation measure, and any City ordinance or regulation, the provisions of this ordinance shall control except that the provision of any Uniform Code shall supersede. SECTION V. Severabilitv. Should any section, subsection, paragraph, sentence, clause or phrase of this ordinance or its application be declared to be unconstitutional or invalid by a court of competent jurisdiction, such decision shall not affect the constitutionality or validity of the remaining portions of this ordinance or its application to any other person or situation. SECTION VI. Effective Date. This ordinance, being an exercise of a power specifically delegated to the City legislative body, is not subject to referendum, and shall take effect five (5j 11 ORDINANCE N0. 5813 days after its passage, approval and after publication of a summary of this ordinance in the City's official newspaper. The summary shall consist of this ordnance's title. PASSED BY THE CITY COUNGL this 8th day of August 2016. t,1 ' / ; Jaso A. Seth,{y Clerk APPROVED BY THE MAYOR this 8th day of August 2016. Denis Law, Mayor Approved as to form: t'—_ 1``',::,,:"" s,;;; fr t;,r orU ; Lawrence J. Warren, City Attorney y '` v, p u Date of Publication: 8/12/2016 (summary) c,;. ' ORD.1926:6/13/16:scr 12 ORDINANCE N0. 5813 ATTACH M ENT A s E j ` rt 4 City Limits ti: i Ui dMI.ir ' ..` i . '".i'5,N 21 S*T.T"" I ' 4 °..F"tNE215TST. ,' -, bi Planned Action Study Area u r1» ,, Ubdfea a.s '"' w NE215T ST'S o ZCentral NE 20TH,ST• 1" a l t SOUth i",` `= i Q a.w .... f Y NE;19TH ST*', Sunset Mixed Use y r t 2 g s'i.k" °'? a: Z,. :, t,--- Potential Sunset a. x t. °'•. NE 18TH ST. a ' " Terrace Redevelopment u N fi ' t 6 "'T ',' m N r .."'. , m,; $ l 1,9 . A Ir ' 'a.,: 5 r.., _ ' T ,Pa NE16 ..'^"~ w•.. , Y N Hs ti` ' a hf 15TH"ST w ', l -,g o soo t,00a s_ r w' q . ,+, ,., ! ..:, eet NE STH+PL X c, . r y z .C" s» Q;f X f z W , : l',:.f G c .,x e^ W 1 o Z wu..-. x" o NE 14 TH 5TyR3t NE'14T ST wyt - , r''NEI3THPl "-, "l; a ' wa c.'j _ w w t.5- N 1,, N,Swe;a., - ae 0"j s , e 1.' `NE 13THs5T A4,,,,; a g` ;Z :l ".13 s m- o"+> e " . " NE 12TH 5 Y T s: k ` Q vi W M . ' - Q„r„ . 2 _ ` I '+;,,, 4, tl ... Y, # s ' a. U" "t p r. QgW PPRKpR " y, 3 ( a O Q O i NE. r'Pi, -N •o 3 q,' ;, Q y'z . - 3 ZE "' **'',' xw w ' t, A` ; +"NE 11TH ST ' co. h J p t..r ae '¢. a „r,Y _ } J y' Z i" m i; w., i e ' ,NE y1,0TH.P.L*'c Je' ryQ, ' _ ..4`•jzy Q"+wt'.` '`i we "'IIMSr ral w.r. y r F s t i,- .awl4+t ,.sR W ro s .. y iz, p Ill ."+m' 1r w p•N s'^'NE 1OTH PL, "' i 10' Q i; 4,5~` ' a q, . 'Q J T q r 7.{ NE$0 5 , o x' W M " z 0 s r, ` c ,.+ IzM, 1"' =0 v,'"°'S1 •' x p "'_ waii w w j F.!° `''j j'Q . ,_ NE.9TH PL i.o Z w z NE•lOTH ST Z - , a a i I iM . a _w W ','"` 8 +m a rJ "ar krt a ;t 5 ; t w Fc p,rt ll fAil,'Ymdf r`^ _ t k@ '.•aii, u a d a a,F,_r a i..:..i- F - en,.„fr m. i y, 4. . 'k i`,' e' O x O -*p"` NE 9TH ST ,haa; NE 9TH ST 1 Q o a ilf;0 ,;g! fi rr ' a,,T t.+l 1 w. S:^;iG`a*no-.' yL, 'a q,rc,, r z 3 .*, r. rt ,e ;z 3 z j+.—s_ y ..::s +;:zRF `c 'WLF. W ''W.Y , T iR.r % ' Z ' ' NE 8TH:PL ,c Q"'4.r w ,. 'b,:, € a ra . srr: € r` wi lE`:s *3 t +L +-j '' "` 7"f a d r 4'a , NE '`R Y 'O Zx 'y3t' e ^ t ,ry 6e , s ad S e.... a r ,'Q :il! Z k#1 -Np .' j +,,"' r"'+ .ro=c' w" NE STH ST.gy N S N`1 iu W xi'iw . r. g t . y g' gF.. aII Y P}Lf 3Y`i j''':'' s'' Z {Z b iy.'•-,t.,* Y j ' .. fRd,'j sau,. 0.r.rz.. g s> +F + 'tw' a " r""` S'( ,' .,. i NE6 ,y v. -r Q x , aZ,H ""'v i+'S, iTHp rFt'g`+ .-ir4.N 7 Z k '' ,'" 1 ._: v Fr NE H 571, E 6TN CIR t 'a l:,L'.a'Tysl Z "'' s.3r'. `: :. t ,' fia'-'. `w zd r Z `" ,, ,, ` ,, r aa a .,y i _ O ,' , m , , . Ar =r' Source CityofRe nton,King ounty L` *""''' . ' ' ., p rr1 '* ` q": 4 y n I * S/ g a `,,. -g'' `. ;k: m," ai NE•TH P"=`' ;a;"S'' Attachment A Planned Action Study Area TEe,AnorfA Sunset Area Community Planned Action Final NEPA/SEPA EIS ORDINANCE N0. 5813 ATTACHMENT B Attachment B: Sunset Area Community Planned Action EIS Mitigation Measures Table of Contents Introductionand Purpose ......................................................................................................................3 SEPATerms.............................................................................................................................................3 GeneralInterpretation...........................................................................................................................4 Summary of Proposal,Alternatives, and Land Capacity........................................................................4 Proposaland Alternatives................................................................................................................4 LandCapacity...................................................................................................................................5 Location..................................................................................................................................................6 MitigationDocument.............................................................................................................................9 1. Earth..................................................................................................................................10 2. AirQuality.........................................................................................................................12 3. Water Resources...............................................................................................................18 4. Plants and Animals............................................................................................................20 5. Energy...............................................................................................................................22 6.Noise.................................................................................................................................25 7. Environmental Health.......................................................................................................27 8. Land Use............................................................................................................................30 9. Socioeconomics................................................................................................................32 10. Housing.............................................................................................................................34 11. Environmentallustice.......................................................................................................36 12. Aesthetics..........................................................................................................................38 13. Historic/Cultural................................................................................................................41 14. Transportation..................................................................................................................44 15. Parks and Recreation........................................................................................................48 16. Public Services...................................................................................................................51 17. Utilities..............................................................................................................................56 AdvisoryNotes .....................................................................................................................................61 Attachment 1: Draft EIS, Cultural Resources Appendix J, Plan and Procedures for Dealing with the Unanticipated Discovery........................................................................................................62 Attachment 2: Figure 3.17-1 Potential Subarea Utility Improvements and Phasing........................64 Wate r....................................................................................................................................................65 Overview........................................................................................................................................65 Edmonds-Glenwood Phase 1.........................................................................................................65 NewLibrary....................................................................................................................................65 New Mixed-Use Building Adjacent to New Library..............................................................................66 RHA's Piha Site...............................................................................................................................66 Pldnned ACtiOn OfdindnCe 1 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B SunsetTerrace Redevelopment.....................................................................................................67 Edmonds-Glenwood Phase 2.........................................................................................................67 WaterMain Costs..........................................................................................................................68 WastewaterCollection.........................................................................................................................68 Overview........................................................................................................................................68 DetailedDiscussion........................................................................................................................68 List of Tables Table 1. Summary of Land Capacity-Planned Action Alternatives...................................................6 Table2. Earth Significant Impacts....................................................................................................................10 Table 3. Earth Mitigation Measures.................................................................................................................11 Table 4. Air Quality Significant Impacts.........................................................................................................12 Table 5. Air Quality Mitigation Measures......................................................................................................14 Table 6. Potential Greenhouse Gas Reduction Measures........................................................................16 Table 7. Water Resources Significant Impacts............................................................................................18 Table 8. Plants and Animals Significant Impacts........................................................................................20 Table9. Energy Significant Impacts................................................................................................................22 Table10.Energy Mitigation Measures..............................................................................................................24 Table 11.Noise Significant Impacts...................................................................................................................25 Table 12.Noise Mitigation Measures.................................................................................................................26 Table 13.Environmental Health Impacts........................................................................................................27 Table 14.Environmental Health Mitigation Measures...............................................................................28 Table15.Land Use Impacts...................................................................................................................................30 Table 16.Land Use Mitigation Measures.........................................................................................................31 Table 17.Socioeconomics Impacts.....................................................................................................................32 Table 18.Socioeconomics Mitigation Measures...........................................................................................34 Table19.Housing Impacts.....................................................................................................................................34 Table 20.Housing Mitigation Measures...........................................................................................................36 Table 21.Environmental Justice Impacts........................................................................................................36 Table 22.Environmental Justice Mitigation Measures...............................................................................38 Table23.Aesthetic Impacts...................................................................................................................................38 Table 24.Aesthetic Mitigation Measures.........................................................................................................41 Table 25.Historic/Cultural Impacts..................................................................................................................41 Table 26.Historic/Cultural Mitigation Measures.........................................................................................42 Table27.Transportation Impacts......................................................................................................................44 Table 28.Transportation Mitigation Measures.............................................................................................46 Table 29.Parks and Recreation Impacts..........................................................................................................48 Table 30.Parks and Recreation Mitigation Measures................................................................................49 Table31.Public Services Impacts.......................................................................................................................51 Table 32.Public Services Mitigation Measures.............................................................................................54 Table33.Utilities Impacts......................................................................................................................................56 Table 34.Utilities Mitigation Measures............................................................................................................59 Planned Action Ordinance z Attachment B:nnitigation Document ORDINANCE N0. 5813 ATTACHMENT B Introduction and Purpose The State Environmental Policy Act(SEPA) requires environmental review for project and non- project proposals that are likely to have adverse impacts upon the environment. In order to meet National Environmental Policy Act(NEPA) and SEPA requirements,the City of Renton issued the Draft Environmental/mpactStatement(DEIS)for the Ciry of Renton SunsetArea Community Planned Action on December 17,2010 and the Final EnvironmentallmpactStatement(FEIS)for the Ciry of Renton SunsetArea Community Planned Action on April 1,2011. The Draft together with the Final EIS is referenced herein as the"EIS".The EIS has identified significant beneficial and adverse impacts that are anticipated to occur with the future development of the Sunset Planned Action area, together with a number of possible measures to mitigate those significant adverse impacts.A NEPA Reevaluation/SEPA Addendum was prepared in September 2014 and issued in December 2014 to evaluate any potential changes in EIS conclusions associated with modifications to the conceptual master plan for Sunset Terrace,which comprises a portion of the Planned Action area. Similarly,a NEPA Reevaluation/SEPA Addendum was prepared in May 2016 and issued in June 2016,based on a revised master plan for Sunset Terrace and associated housing replacement sites. No new or significantly different impacts were identified from this reevaluation. The purpose of this Mitigation Document is to establish specific mitigation measures,based upon significant adverse impacts identified in the EIS and minor changes identified in the Reevaluation/Addendum. The mitigation measures shall apply to future development proposals which are consistent with the Planned Action scenarios reviewed in the EIS,and which are located within the Renton Sunset Area Community Planned Action Study Area(see Exhibit A). This document will be used primarily to facilitate review of future projects proposed as planned actions. SEPA Terms As used in this document,the words action,planned action,or proposal are defined as described below. Action"means projects or programs financed,licensed,regulated,conducted or approved by a governmental Agency."Project actions"involve decisions on a specific project such as a construction or management activity for a defined geographic area. "Non-project"actions involve decisions about policies,plans or programs. (see WAC 197-11-704) Planned Action"refers to types of project actions that are designated by ordinance for a specific geographic area and addressed in an EIS,in conjunction with a comprehensive plan or subarea plan,a fully contained community,a master planned resort,a master planned development or phased project. (see WAC 197-11-164) Proposal"means a proposed action that may be an action and regulatory decision of an agency, or any action proposed by applicants. (see WAC 197-11-784) Pldnned ACtiOn OfdinanC2 3 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B General Interpretation Where a mitigation measure includes the words"shall"or"will,"inclusion of that measure in project plans is mandatory in order to qualify a project as a Planned Action. Where"should"or"would" appear,the mitigation measure may be considered by the project applicant as a source of additional mitigation,as feasible or necessary,to ensure that a project qualifies as a Planned Action. Unless stated specifically otherwise,the mitigation measures that require preparation of plans, conduct of studies,construction of improvements,conduct of maintenance activities,etc.,are the responsibility of the applicant or designee to fund and/or perform. Summary of Proposal, Alternatives, and land Capacity Proposal and Alternatives The proposal is to redevelop the Sunset Terrace public housing community and promote associated neighborhood growth and revitalization as part of a Planned Action.Redevelopment of the public housing community and adoption of a Planned Action Ordinance would encourage redevelopment in the Planned Action Study Area through land use transformation and growth,public service and infrastructure improvements,and a streamlined environmental review process.The Renton Housing Authority(RHA) is the proponent of the proposal's primary development action, redevelopment of the existing Sunset Terrace public housing community;however,RHA wou(d likely redevelop the property in partnership with other public and private non-profit and for-profit developers and agencies.The City of Renton(City) is responsible for public service and infrastructure improvements for Sunset Terrace and the broader Sunset Area Community neighborhood,is the agency responsible for streamlining local permitting and environmental review through this Planned Action,and is the agency that would regulate private neighborhood redevelopment in accordance with its Comprehensive Plan and development regulations. The City analyzed three alternatives(Alternatives 1,2,and 3) as part of the Draft EIS to determine its Preferred Alternative.The Preferred Alternative is evaluated in the Final EIS.A Reevaluation Alternative was developed through a NEPA Reevaluation and SEPA Addendum process in 2014. Similarly,a 2016 Reevaluation Alternative was evaluated through a NEPA Reevaluation and SEPA Addendum in 2016.All six alternatives are described below. Alternative 1 (No Action). RHA would develop affordable housing on two vacant properties,but it would not redevelop the Sunset Terrace pub ic housing property.Very limited public investment would be implemented by the City,resulting in lesser redevelopment across the Planned Action Study Area.A Planned Action would not be designated.The No Action Alternative is required to be studied under NEPA and SEPA. Alternative 2.This alternative represents a moderate level of growth in the Planned Action Study Area based on investment in mixed-income housing and mixed uses in the Potential Sunset Terrace Redevelopment Subarea,targeted infrastructure and public services throughout the Planned Action Study Area,and adoption of a Planned Action Ordinance. Alternative 3.This alternative represents the highest level of growth in the Planned Action Study Area,based on investment in the Potential Sunset Terrace Redevelopment Subarea with a greater Planned Action Ordinance 4 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B number dwellings developed in a mixed-income,mixed-use sryle,major public investment in study area infrastructure and services,and adoption of a Planned Action Ordinance. Preferred Alternative. This alternative represents neighborhood growth similar to and slightly less than Alternative 3 in the Planned Action Study Area,based on investment in the Potential Sunset Terrace Redevelopment Subarea with a moderate number dwellings developed in a mixed-income, mixed-use style oriented around a larger park space and loop road,major public investment in study area infrastructure and services,and adoption of a Planned Action Ordinance. 2014 Reevaluation Alternative.This alternative proposes neighborhood growth the same as Alternative 3,with slightly more units(approximately 90) redirected to the Sunset Terrace subarea. Sunset Terrace would have a mixed-income,mixed-use development similar to Alternative 3 and the Preferred Alternative,with a larger park and with dwellings focused more along SR 900. Greenstreets,library uses,and other investments would be similar to those proposed for Alternative 3 and the Preferred Alternative. 2016 Reevaluation Alternative.An amended master plan was developed in 2016 addressing RHA revised proposals to develop replacement housing for the Sunset Terrace redevelopment on five parcels located outside but abutting the 2014 Master Plan area-three parcels would be added to the Sunset Court Park site and developed with 50 apartments and townhomes,and two parcels would be added to properties north of the"loop road"in the Harrington Park development providing 19 townhomes.Within the 2014 Master Plan boundaries there would also be unit transfers from one site to another.With the 2016 revisions to the Master Plan and addition of the abutting parcels,there would be no net increase in the total number of housing units in the Master Plan area or in the Sunset Area neighborhood. However,consistent with the flexibility allowed by the adopted Master Plan,some units would be redistributed. Land Capacity To determine future growth scenarios for the next 20 years,a land capacity analysis was prepared. The alternatives produce different future growth estimates. Each would affect different amounts of property. Alternative 1 assumes that about 16%(35 acres) of the 213 net acres of Planned Action Study Area parcels would infill or redevelop. Alternative 2 assumes that about 32%(68 acres) of the Planned Action Study Area parcels would infill or redevelop. Alternative 3 assumes that approximately 40%(84 acres] of the Planned Action Study Area parcels would infill or redevelop. The Preferred Alternative assumes that approximately 40%(84 acres) of the Planned Action Study Area parcels would infill or redevelop. The Reevaluation Alternatives 2014 and 2016 assume the same Planned Action Study Area growth levels as Alternative 3,with slight differences in distribution towards the Sunset Terrace subarea. The latter three alternatives-Alternative 3,the Preferred Alternative,and the Reevaluation Alternatives in 2014 and 2016 which are similar-represent the higher growth levels studied in the EIS and differ,when compared at the Planned Action area as a whole,by about 7%;these three Planned Action Ordinance 5 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B alternatives are considered for the purposes of this mitigation document to be the"Planned Action Alternatives." This mitigation document is based on the range of growth considered in the Planned Action Alternatives.More details on the components of the alternatives can be found in Final EIS Chapter 2 and the Reevaluation subsections below(as well as Attachment I of the NEPA Record of Decision). Table 1. Summary of Land Capacity— Planned Action Alternatives INet New Growth Alternative 3/Reevaluation Dwelling Units/Jobs Alternative Preferred Alternative Dwelling units 2,506 2,339 Population 5,789 5,403 Employment SF 1,310,113 1,247,444-1,259,944 Jobs 3,330 3,154-3,192 Reevaluation Alternative: 2014 In November 2014,the City conducted a NEPA Reevaluation pursuant to Section 58.47 of US Department of Housing and Urban Development's(HUD's) NEPA regulations.SEPA also provides a process using an Addendum to the prior FEIS where information or analysis does not substantially change prior conclusions about impacts(WAC 197-11-706). Based on updated master planning in 2014, some changes in units were considered(90 more units than Alternative 3).See Tables 2 and 3. Table 2. Reevaluation-Total Units Under Review Total Units Reviewed in Site Name EIS Study Area Status Acres Reevaluation A Glennwood Townhomes Sunset Terrace Redevelopment Constructed RHA 0.65 8 B Kirkland Avenue Townhomes Swap Site, North Study Area Under Construction RHA 0.77 18 C Edmonds Apartments Sunset Terrace Redevelopment Future Development RHA 1.70 112 D Sunset Terrace Apartments Sunset Terrace Redevelopment Part of Master Site Plan 0.51 54 E Sunset Park West Townhomes Sunset Terrace Redevelopment Part of Master Site Plan 0.55 20 F Sunset Court Townhomes Swap Site,Central Study Area Future Development RHA 0.88 15 6 Sunset Park East(Piha)Townhomes&Apts Sunset Terrace Redevelopment Part of Master Site Plan 1.09 57 H Sunset Terrace Dev.Building A Sunset Terrace Redevelopment Part of Master Site Plan 0.99 117 I Sunset Terrace Oev.Building B Sunset Terrace Redevelopment Part of Master Site Plan 1.18 196 1 Sunset Terrace Dev.Suilding C Sunset Terrace Redevetopment Part of Master Site Ptan 0.74 110 K Renton Highlands Library Sunset Terrace Redevelopment Part of Master Site Plan See H L Regional Stormwater Facility Sunset Terrace Redevelopment Part of Master Site Plan See M M Sunset Fark Sunset Terrace Redevelopment Part of Master Site Plan 3.2 N Sunset Lane loop tmprovements Sunset Terrace Redevelopment Part of Master Site Plan 1.41 0 NE 10th Street Extension Improvements Sunset Terrace Redevelopment Part of Master Site Plan 0.20 X _Library Site(2013) Swap Site,Central Study Area Future Development 1.41 25 Totals 15.28 722 Note:Units may be redistributed among sites provided the Reevaluation conclusions are maintained. Total Units:Difference Master Plan Proposals with EIS Preferred Alternative 209 Total Units:Difference with EIS Alternative 3 90 Sources:Veer,Schemata,Colpitts,City of Renton,Renton Housing Authority,Mlthun,BERK 2014 Planned Action Ordinance 6 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Notes: Shaded sites=Master Plan Sites. Table 3. Comparison of Net Growth in Sunset Terrace and Neighborhood Alternatives Net New Growth I Alternative 3 I Preferred Alternative I Reevaluation Alternative Dwelling Neighbor- St nset Neighbor- Sunset Neighbor- Sunset Units/Jobs hood Terrace hood 1'errace hood - Tei i ace Dwelling units 2,506 79 2,339 2b6a . 2,506 554 Population 5,789 I,106 5,403 - : t 14 : 5,789 2,279 : EmploymentSF 1,310,113 <.:9,p(t0" . 1,247,444- 38 1Qf} 1,310,113 19,50F}-_ 1,259,944 4,{pQ Jobs 3,330 1$Z 3,154- - llfi - " 3,330 6p-.$2 3,192 a Does not include approximately 90-100 units to be developed on land swap/housing replacement sites. b Similar to the FEIS,the Sunset Terrace study area Master Plan sites D,E,G to J and L to 0,plus sites A and C. Source: FEIS 2011,BERK 2014 The City also proposed a larger park than was considered under either of the selected alternatives, and accordingly some buildings increased in height or numbers of units.Some streets were proposed for reclassification to achieve the circulation proposals and"green streets"in the Final EIS. Setbacks of buildings from the future SR 900 improvement boundaries are less than for the Preferred Alternative. As the analysis in the Reevaluation shows,no substantive changes in conclusions or required mitigation are needed as a result of the revised alternative,termed the"2014 Reevaluation Alternative." Reevaluation Alternative: 2016 The proposed developments would meet City standards for density,height,setbacks,transportation levels of service,connection to utilities,and would be subject to City parking codes,including procedures for modifying applicable standards.The new developments would be incorporated into an amended Master Plan pursuant to RMC Title IV.Also,the SEPA Planned Action Ordinance could be amended to include the revised Master Plan concept. In total,722 dwelling units are being proposed in the study area,which is to the same as the number of units considered in the 2014 Reevaluation.See Table 4. Table 4.Summary of Total Units Proposed for Study in Reevaluation land Area Total and Area Total Commerci Location acres): Dwelling ( acres : Dwelling al Square 2014 Units: 2016) Units: Feet:2014 2014 2016 and 2016 Master Plan Sites I Sunset Terrace and Replacement Sites:C through 1 I 7.63 I 671 9.23 671 4,500- 39,500 Pldnned ACtiOn OrdinanCE Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B land Area Total and Area Total Commerci Dwelling Dwelling al5quareLocationacres): acres : 2014 Units: 2016) Units: Feet:2014 2014 2016 and 2016 Library(Site K)I 15,000 Sunset Park and Regional Stormwater Facility(Sites L I 3 2 I 3.20 and M)I I NE lOth and Sunset Lane Loop(Site N and 0) I 1.61 1.61 I Total Master Plan Sites I 12.44 671 14.04 I 671 I 19,500- 54,500 Other Sunset Terrace Study Area Sites:Glenwood I 0.65 8 I 0.65 8 ISiteA)-Developed Swap Sites:Kirkland Avenue(B)-Developed,Library I 2.18 43 I 2.18 43 ISiteforFutureSurplus(X) Other Employment potential in Sunset Terrace and I I 4,500 Replacement Sites I Total All Sites 15.28 7Z2 I 16.88 f 722 I 19,500- 59,000 Source:King County Assessor;ICF Jones&Stokes et al.2011;BERK Consulting 2016 A comparison of the Reevaluation Alternatives and the Final EIS Alternatives is provided in Table 5. The mitigation documents contained in the ROD and Planned Action Ordinance were based on the range of growth of the two Selected Sunset Area Alternatives. The mitigation measures continue to apply to the Reevaluation Alternatives in 2014 and 2016. Table 5.Comparison of Net Growth in Sunset Terrace and Neighborhood Alternatives Net New Growth Final EIS Alternative I Final EIS Preferred Reevaluation I Reevaluation 3 Alternative Alternative: 2014 Alternative: 2016 Dwelling Neighbo a tinset Neighbo $uttset Neighbor- `Stutset Neighbor- Stttiset Units/Jobs r-hood Teri`aCe. r-hood fieri'ace hood :TerraCe hood TErrace Dwelling units 2,506 •:.?9;=.. 2,339 266'.: 2,506 ' :554: 2,506 519 Population 5,789 -,5{6 5,403 bl+ 5,789 :::.,27.5,789 1,93 Employment 1,310,11 59,t Qp_ 1,247,44 3$,1p(} 1,310,113 1},SUO- 1,310,113 29,5t 0- SF 3 4- 5.9,t}QCI 59,{Wk0 1,259,94 4 Jobs 3,330 i -.1$2' 3,154- 217 3,330 6i?-182_ 3,330 '{s{1-$2 . " 3,192 a Does not include approximately 90-100 units to be developed on land swap/housing replacement sites. b Similar to the Final EIS,includes the Potential Sunset Terrace Redevelopment subarea and housing replacement sites abutting the subarea and included in the Master Plan. Does not include several housing replacement sites in the neighborhood. Source:Final EIS 2011,BERK 2014 Per the approved 2014 Master Plan,dwelling units may be redistributed among sites provided the Reevaluation conclusions are maintained. Planned Action Ordinance 8 Attachment B:Mit gation Document ORDINANCE N0. 5813 ATTACHMENT B While the net units in Sunset Terrace are lower in 2016 than in 2014 per Table 5,this is a reflection of the boundaries of the 2011 Potential Sunset Terrace Redevelopment Area that did not include several replacement housing sites which were part of the neighborhood growth studied in the EIS. Some of the housing replacement sites are part of the am,ended Master Plan for Sunset Terrace. Some potential dwelling units are proposed to be transferred among three individual Master Plan sites.However,the total number of units that could be developed in the Master Plan area would remain the same.Similarly,the overall neighborhood development and growth would be the same as in 2011 and 2014. See the revised master plan reflecting the 2016 Reevaluation Alternative in the 2016 Reevaluation and Addendum. location The Sunset Terrace public housing community is generally bounded by Sunset Lane NE and Glenwood Avenue NE on the north,NE 10th Street on the east,NE Sunset Boulevard(State Route SR] 900) on the south,and Edmonds Avenue NE on the west.See Exhibit A of the Planned Action Ordinance. The Sunset Terrace public housing community is part of the Sunset Area Community neighborhood. This broader neighborhood is the Planned Action Study Area considered in the EIS;it is generally bounded by NE 21st Street on the north,Monroe Avenue NE on the east,NE 7th Street on the south, and Edmonds Avenue NE.See Exhibit A of the Planned Action Ordinance. Mitigation Document Based on the EIS and Reevaluation/Addendum(2014 and 2016)this Mitigation Document identifies significant adverse environmental impacts that are anticipated to occur as a result of development of planned action projects. Mitigation measures identified in the EIS are reiterated here for inclusion in proposed projects to mitigate related impacts and to qualify as Planned Action projects. Consistency review under the Planned Action,development plan review,and other permit approvals will be required for specific development actions under the Proposed Action pursuant to WAC 197- 11-172.Additional project conditions may be imposed on planned action projects based upon the analysis of the proposal in relationship to independent requirements of the City,state or federal requirements or review criteria. Any applicant for a project within the Planned Action area may propose alternative mitigation measures,if appropriate and/or as a result of changed circumstances,in order to allow equivalent substitute mitigation for identified impacts. Such modifications shall be evaluated by the City's SEPA Responsible Official prior to any project approvals by the City. In combination,regulations applicable to each element of the environment and mitigation measures identified in the EIS and documented in this Mitigation Document that are applied to any planned action proposal will adequately mitigate all significant environmental impacts associated with planned action proposals,except for those impacts that are identified as"significant unavoidable adverse impacts." Planned Action Ordinance 9 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Provided below for each element of the environment analyzed in the EIS for the proposed action are: a) summary of significant environmental impacts (construction,operation,indirect and cumulative); b)a summary of unavoidable adverse impacts; c) mitigation measures established by this mitigation document for both the Planned Action Study Area as a whole as well as the Potential Sunset Terrace Redevelopment Subarea; and d) a list of City policies/regulations on which mitigation measures are based. Advisory notes are included at the end of the document to list the federal,state,and local laws that act as mitigation measures. 1. Earth Significant Impacts Table 2. Earth Significant Impacts Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea Construction Erosion could increase as a result of soil Same as Planned Action Study Area disturbance;however,much of the existing soils are glacial outwash materials with low erosion potential. Codified best management practices minimize the potential for both erosion and erosion transport to waterways. Construction could require import and Similar to Planned Action Study Area. export of earth materials;however,The underlying glacial outwash soils with minimal planning and protection, have the highest potential for reuse the outwash soils in most of the study within the Planned Action Study Area area could be reused as backfill, and consequently the subarea. minimizing import and export. There is an increased risk of landsliding There are no mapped geologic hazards, due to soil disturbance,changing and thus a low potential for impacts. drainage,or temporarily oversteepening slopes.However,a relatively small proportion of the study area is considered either steep slope or erosion hazard.Both the glacial outwash and till soils are generally strong and of low concern regarding slope instability. Operations Active seismicity in the Planned Action Same as Planned Action Study Area Study Area would require that inhabited structures,including buildings,bridges,and water tanks,be designed to withstand seismic loading. ndirect The major steep slope,erosion,and There are no mapped geologic hazards, Planned A[tion OfdinanCe 10 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea landslide hazard areas within the and thus a low potential for impacts. Planned Action Study Area extend beyond the study area boundaries. Development on the slope above inside)the study area boundary could increase the risk of erosion and landsliding downslope(outside)ofthe study area. Cumulative Same as indirect impacts above; There are no mapped geologic hazards, intensive development around this and thus a low potential for impacts. hazard area outside of the Planned Action Study Area by other projects is not currently anticipated,but could increase the risk of erosion and landsliding. Unavoidable Adverse Impacts There are no significant unavoidable adverse earth impacts. Mitigation Measures Table 3. Earth Mitigation Measures Planned Action Study Area Potential Sunset Terrace Redevelopment Subarea The following mitigation measures shall apply to Mitigation measures shall be the same as the development throughout the Planned Action Planned Action Study Area,except that there are Study Area. no geologic hazard areas to avoid. Apply erosion-control best management practices(BMPs),as described in Appendix D of the Ciry of Renton Amendments to the King CountySurface WaterDesign Manuall. Limit development in geologic hazard areas and their buffers,or require rigorous engineered design to reduce the hazard,as currently codified. Planned Action applicants shall identify in their applications the source of earth material to be used in construction and shall consider earth material reuse and provide information to the City regarding why earth material reuse is not feasible if it is not proposed. The City may condition the planned action application to provide for earth material reuse where feasible. 1 City of Renton.2010.City ofRenton Amendments to the King CountySurface Water Design Manual. February. Appendix D,Erosion and Sedimentation Control Standards. Planned ACtion OrdinanCe 11 Attachment B:Mitigation Dotument ORDINANCE N0. 5813 ATTACHMENT B Nexus City of Renton Comprehensive Plan RMC 4-3-050 Critical Areas Regulations RMC 4-4-030 Development Guidelines and Regulations—General RMC 4-4-060 Grading,Excavation and Mining Regulations RMC 4-5-050 International Building Code RMC 4-6-030 Drainage(Surface Water) Standards 2. Air Quality Significant Impacts Table 4. Air Quality Significant Impacts Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea Construction Dust from excavation and grading Same as Planned Action Study could cause temporary,localized Area increases in the ambient concentrations of fugitive dust and suspended particulate matter. Construction activities would likely Same as Planned Action Study require the use of diesel-powered, Area heavy trucks and smaller equipment such as generators and compressors.These engines would emit air pollutants that could slightly degrade local air quality in the immediate vicinity of the activity. Some construction activities could Same as Planned Action Study cause odors detectible to some Area people in the vicinity of the activity, especially during paving operations using tar and asphalt.Such odors would be short-term and localized. Construction equipment and Same as Planned Action Study material hauling could temporarily Area increase traffic flow on city streets adjacent to a construction area.If construction delays traffic enough to significantty reduce travel speeds in the area,general traffic-related emissions would increase. Operations Emissions from Stationary equipment,mechanical Same as Planned Action Study Commerciat Operations equipment,and trucks at loading Area Pldnn2d ACtion OrdinanCe 12 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea docks at office and retail buildings could cause air pollution issues at adjacent residential property. However,new commercial facilities would be required to register their pollutant-emitting equipment and to use best available control technology to minimize emissions. Emissions From Vehicle Tailpipe emissions from vehicles The forecasted VMT from the Travel would be the major source of air subarea is only a small fraction of pollutant emissions associated with the Puget Sound regional totals. growth.The net increases in vehicle Future emissions from increased miles travelled(VMT)forecast as a population and motor vehicles in result of Planned Action the subarea would not cause alternatives are inconsequentially significant regional air quality small compared to the Puget Sound impacts. regional VMT and its implied impact on regional emissions and photochemical smog.This would not alter Puget Sound Regional Council's conclusion that future regional emissions will be less than the allowable emissions budgets of air quality maintenance plans. Air Quality Attainment Land use density and population Same as Planned Action Study Status would increase in the Planned Area. Action Study Area;however,these increases represent only a small fraction of the Puget Sound regional totals.Furthermore,this alternative would not result in land use changes that include unusual industrial developments.Therefore, development in the Planned Action Study Area would not cause a substantial increase in air quality concentrations that would result in a change in air quality attainment status. Greenhouse Gas Emissions: Planned Action alternatives are Planned Action Alternatives Study Area and Subarea estimated to result in this would result in an estimated alternative would result in an 3,760 to 6,612 metric tons/year estimated 43,050 to 45,766 metric of GHG emissions. tons/year of greenhouse gas(GHG) emissions for the Planned Action Study Area. Outdoor Air Toxics The Planned Action Study Area is in Impacts on outdoor air toxics a mixed-use residential and would be similar to those commercial zone that does not described for the Planned Action include unusual sources of toxic air Study Area. pollutants.The major arteriat street Planned ACtiOn OfdinanCe 13 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea through the Planned Action Study Area(NE Sunset Boulevard)does not carry an unusually high percentage of heavy-duty truck traffic.Thus,the Planned Action Alternatives would not expose existing or future residents to disproportionately high concentrations of toxic air pollutants generated by local emission sources. Indoor Air Toxics See Potential Sunset Terrace RHA development would be Redevelopment Subarea constructed according to local building codes that require adequate insulation and ventilation.Regardless,studies have shown that residents at lower-income developments often suffer higher rates of respiratory ailments than the general public.Therefore,the City and RHA will explore measures to improve indoor air quality beyond what is normally achieved by simply complying with building codes. lndirectand Cumulative Greenhouse Gas Emissions: With the highest level of transit- With the highest level of transit- Subarea,Study Area,and oriented development in the study oriented development in the Region area of the studied alternatives,subarea of the alternatives Planned Action Alternatives would studied,Planned Action provide the greatest regional GHG Alternatives would provide the emission reductions,a net greatest reduction in regional reduction of 3,907-4,164 metric GHG emissions,a net reduction of tons/year,compared with the No 150-467 metric tons/year, Action Alternative studied in the compared with the No Action EIS.Alternative studied in the EIS. Unavoidable Adverse Impacts No significant unavoidable adverse impacts on regional or local air quality are anticipated. Temporary,localized dust and odor impacts could occur during the construction activities.The regulations and mitigation measures described below are adequate to mitigate any adverse impacts anticipated to occur as a result of study area growth increases. Mitigation Measures Table 5. Air Quality Mitigation Measures Planned Action Study Area Potential Sunset Terrace Redevelopment Subarea Planned Action Ordinance 14 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Planned Action Study Area Potential Sunset Terrace Redevelopment Subarea Construction Emission Control In addition to the mitigation measures for air The City shall require all construction contractors quality described under the Planned Action Study to implement air quality control plans for Area,the following mitigation measures apply: construction activities in the study area.The air . Should the phases of the Potential Sunset quality control plans shall include BMPs to Terrace Redevelopment Subarea occur control fugitive dust and odors emitted by diesel concurrently rather than in a phased and construction equipment. sequential manner,the City and RHA wiil The following BMPs shall be used to control consider adding the Northeast Diesel fugitive dust. Collaborative Diesel Emission Controls in Construction Projects-Model Contract Use water sprays or other non-toxic dust Specifications or an equivalent approachz as control methods on unpaved roadways. additional mitigation measures. Minimize vehicle speed while traveling on . The City and RHA and other public or private unpaved surfaces. applicants within the subarea should explore Prevent trackout of mud onto public streets. measures to improve indoor air quality beyond what is normally achieved by simply complying Cover soil piles when practical. with building codes.For example,grant Minimize work during periods of high winds Programs such as the Breath Easy Homes when practical. program could provide funding to foster construction methods that reduce dust,mold,The following mitigation measures shall be used and air toxics concentrations in the homes,such to minimize air quality and odor issues caused by as the following:tailpipe emissions. o use of low-VOC [volatile organic compounds] Maintain the engines of construction building materials and coatings, equipment according to manufacturers' o enhanced building ventilation and room air specifications. filtration,and Minimize idling of equipment while the o installation of dust-free floor materials and equipment is not in use. low-pile carpeting to reduce dust buildup. Where feasible,Applicants shall schedule haul • Planned Action applicants for residential traffic during off-peak times(e.g.,between 9:00 developments shall provide information a.m.and 4:00 p.m.)to have the least effect on regarding the feasibility and appticability of traffic and to minimize indirect increases in traffic ndoor air quality measures.The City may related emissions. This shall be determined as condition Planned Action applications to part of traffic control plans required in Section 14 ncorporate feasible indoor air quality of this mitigation document. measures. Burning of slash or demolition debris shall not be permitted without express approval from Puget Sound Clean Air Agency(PSCAA).No slash burning is anticipated for any construction projects in the Planned Action Study Area. Greenhouse Gas Reduction Measures Please see text and Table 6 below. Greenhouse Gas Reduction Measures The City shall require development applicants to consider the reduction measures shown in Table 6 for their projects,and as part of their application explain what reduction measures are included and z Northeast Diesel Collaborative.December 2010.Diesel Emission Controls in Construction Projects,Model Contract Specification.Available:<http://www.northeastdiesel.org/pdf/NEDC-Construction-Contract-Spec.pdf.> Accessed:March 14,2011. Planned Action Ordinance 15 Attathment B:Mitiga[ion Dotument ORDINANCE N0. 5813 ATTACHMENT B why other measures found in the table are not included or are not applicable.The City may condition Planned Action applications to incorporate feasible GHG reduction measures. Table 6. Potential Greenhouse Gas Reduction Measures Reduction Measures Comments Site Design Plant trees and vegetation near structures to shade Reduces on-site fuel combustion emissions and buildings. purchased electricity,and enhances carbon sinks. Minimize building footprint. Reduces on-site fuel combustion emissions and purchased electricity consumption,materials used,maintenance,tand disturbance,and direct construction emissions. Design water efficient landscaping. Minimizes water consumption,purchased energy,and upstream emissions from water management. Minimize energy use through building orientation. Reduces on-site fuel combustion emissions and purchased electricity consumption. Building Design and Operations Construct buildings according to City of Seattle The City of Seattle code is more stringent than energy code. the current City of Renton building code. Apply Leadership in Energy and Environmental Reduces on-site fuel combustion emissions and Design(LEED)standards(or equivalent)for design off-site/indirect purchased electricity,water and operations. use,waste disposal. Purchase Energy Star equipment and appliances for Reduces on-site fuel combustion emissions and public agency use. purchased electricity consumption. Incorporate on-site renewable energy production, Reduces on-site fuel combustion emissions and including installation of photovoltaic cells or other purchased electricity consumption. solar options. Design street lights to use energy-efficient bulbs Reduces purchased electricity. and fixtures. Construct"green roofs"and use high-albedo Reduces on-site fuel combustion emissions and roofing materials. purchased electricity consumption. Install high-efficiency heating,ventilation,and air- Minimizes fuel combustion and purchased conditioning(HVAC)systems. electricity consumption. Eliminate or reduce use of refrigerants in HVAC Reduces fugitive emissions.Compare systems. refrigerant usage before/after to determine GHG reduction. Maximize interior day tighting through floor plates, Increases natural/day lighting initiatives and increased building perimeter and use of skylights, reduces purchased electrical energy celestories,and light wells.consumption. Incorporate energy efficiency technology such as Reduces fuel combustion and purchased super insulation motion sensors for lighting and electricity consumption. climate-contro(-efficient,directed exterior lighting. Use water-conserving fixtures that surpass building Reduces water consumption. code requirements. Reuse gray water and/or collect and reuse Reduces water consumption with its indirect rainwater. upstream electricity requirements. Planned Action Ordinance 16 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Reduction Measures Comments Use recycted building materials and products. Reduces extraction of purchased materials, possibly reduces transportation of materials, encourages recycling and reduction of so(id waste disposal. Use building materials that are extracted and/or Reduces transportation of purchased materials. manufactured within the region. Use rapidly renewable building materials. Reduces emissions from extraction of purchased materials. Conduct third-party building commissioning to Reduces fuel combustion and purchased ensure energy performance. electricity consumption. Track energy performance of building and develop Reduces fuel combustion and purchased strategy to maintain efficiency. electricity consumption. Transportation Size parking capacity to not exceed local parking Reduced parking discourages auto-dependent requirements and,where possible,seek reductions travel,encouraging alternative modes such as in parking supply through special permits or transit,walking,and biking.Reduces direct and waivers. indirect VMT. Develop and implement a marketing/information Reduces direct and indirect VMT. program that includes posting and distribution of ridesharing/transit information. Subsidize transit passes.Reduce employee trips Reduces employee VMT. during peak periods through alternative work schedules,telecommuting,and/or flex time. Provide a guaranteed-ride-home program. Provide bicycle storage and showers/changing Reduces employee VMT. rooms. Use traffic signalization and coordination to Reduces transportation emissions and VMT. improve traffic flow and support pedestrian and bicycle safety. Apply advanced technology systems and Reduces emissions from transportation by management strategies to improve operational minimizing idling and maximizing efficiency of local streets. transportation routes/systems for fuel efficiency. Develop shuttle systems around business district Reduces idling fuel emissions and direct and parking ga-ages to reduce congestion and create indirect VMT. shorter commutes. Source:Washington State Department of Ecology 2008b VMT=vehicle miles travelled. Nexus City of Renton Comprehensive Plan RMC 4-4-030 Development Guidelines and Regulations—General RMC 4-4-060 Grading,Excavation and Mining Regulations Planned ACtiOn OrdinanCe 1 Attachment B:Mitigation Document ORDINANCE N. 5813 ATFACHMENT B 3. Water Resources Significant lmpacts Table 7. Water Resaurces 5ignificant Impacts Potential Sunset Terrace Type af Impact Planned Action Study Area Redevetopment Subarea Construction Canstruction impacts on water Same as Planned Action Study Area resources wouid be addressed through compliance with Core Requirement#5 for Erosion and Sediment Control in the Renton Stormwater Manual and compliance with Ecalogy's NPDES Canstruction Stormwater General Permit,if the project results in 1 acre or more of land-disturbing activity.Also see Section 1, Earth,above. Operatians Water Qualiry and Land Implementation of the green All untreated pollution-generating Cover connections and the NE Sunset imperviaus surfaces within the Boulevard reconstruction subarea wfluld be eliminated, project is estimated to result in resulting in a reduction of 1.83 acres a net reduction of nf untreated potlution-generating appraximatety 14.7-15.7 acres surface from the Jahns Creek Basin. of untreated poilution- The estimated change in effective generating impervious area and impervious area would result in a approximately 3.1-6.6 acres of decrease of appraximately 0.51 acre effective impervious area. 11%)to 1.07 acres(23%)compared Exclusive of the Sunset Terrace to existing conditions. Redevelopment Subarea the net The Reevatuation Alternative is in the change in pallutant generating range of the priar analysis of the surfaces is approximately 40-42 Preferred Alternative and Alternative acres reductian.Exclusive of the 3 as documented in the Sunset Terrace Redevelopment Reevaluation/Addendum. Subarea,the net change in effective impervious area would be an increase of approximately 1.3 acres(0.8%to 4.24(2.6%) from existing cqnditions. Considering the reduction in the Potentia]Sunset Terrace Redevelopment Subarea as weit as the overall Planned Action Study Area,the net change in effective imperviaus area would be smaller at 0.75-3.17. lndirect and Cumulative The operations analysis above Same as the Planned Action Study presents cumulative impacts in area. 3n particular,the City proposes terms of total impervious to construct a regionai stormwater Ptanned Action Qrdinance 18 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea surfaces and potential water facility that would be designed to quantity and quality impacts,as maintain active and open recreation well as indirect impacts on space allowing water to be treated receiving water bodies outside within a series of distributed yet of the study area. The Planned integrated small rain gardens along Action Alternatives would the edge of the proposed Sunset implement a drainage master Terrace Park and connecting the plan and mitigation would be subsurface to an underground provided in advance through infiltration bed beneath the open the self-mitigating public space. This will mitigate impacts in stormwater infrastructure the subarea as well as portions of the features including a larger Planned Action Study Area. combination of green connections,regional stormwater flow control,and possible public-private partnership opportunities for retrofits. Unavoidable Adverse Impacts None of the alternatives would have significant unavoidable adverse impacts on water resources, because the redevelopment would likely result in an improvement of runoff and recharge water quality.In addition,the net change in effective impervious area can be adequately mitigated through the self-mitigating features(e.g.,green connections,drainage master plan,etc.) of the Planned Action alternatives and through implementation of the stormwater code,as described below. Mitigation Measures All of the alternatives would involve redevelopment and reduction of existing pollution-generating impervious surfaces in the Planned Action Study Area.In addition,per the requirements of the stormwater code,the redeveloped properties would be required to provide water quality treatment for all remaining pollution-generating impervious surfaces.The net reduction in untreated pollution-generating impervious surfaces throughout the study area is,therefore,considered to result in a net benefit to surface water quality.Each of the alternatives would result in a slight increase in the effective impervious area of the Planned Action Study Area. Self mitigating features of the Planned Action Alternatives are listed below: Under Alternative 3,mitigation would be provided in advance or incrementally through the public stormwater infrastructure features including a combination of green connections, regional stormwater flow control,and possible public-private partnership opportunities for retrofits.Conceptual design and planning of the public stormwater infrastructure would be developed under a drainage master plan for the Study Area.It could be developed in advance of likely through grants or city funds) or incrementally as development occurs depending on opportunity costs of constructing the improvements.The extent and form of the public infrastructure projects would be refined through the drainage master plan development and further design.The goal under Alternative 3 would be to provide sufficient advance public infrastructure improvements to balance the anticipated increase in effective impervious area. Planned Action Ordinance 19 Attachment B:Mitigation Document ORDINANCE NtJ. 5813 ATTACHMENT B This strategy would only require that future developments implement flow-control BMPs,but could eliminate on-site flow control through a development fee or similar funding structure ta compensate for the off-site mitigation provided by the public infrastructure investment, The Preferred Alternative mitigation would be similar ta Alternative 3.Harringtan Avenue NE, including partions of NE 16th and NE 9th streets,has been identified as a high priority Green Connection project.This corridor would be enhanced by narrowing through-traffic lanes to calm traffic,create wide planter areas to accommodate large trees and rain gardens to mitigate stormwater runaff,and create wider sidewalks.This project would be implemented as a public infrastructure retrofit project pending available funds.The remaining green connections projects would likely be implemented as revised roadway standards to require incremental redevelopment of the frontage as redevelopment occurs (constructed either by future developers or the City,depending on availability of funds).In addition to the Green Connections projects,the City will implement regional detention/retention irnpravements to provide advance mitigation for future increases in impervious area that could result from redevelopment.I,ocations of the regionai facilities would include the western margin of the newly created park at Sunset Terrace and/or the northern corner of Highlands Park(beyond the outfield of the existing baseball Jsoftball field),A drainage master plan will be developed far the Preferred Alternative. The Reevaluation Alternative is similar to and in the range of impervious results for the Preferred Alternative and Alternative 3 and will be subject to the Sunset Area Surface Water Master Plan,and associated strect frontage improvements,and will be consistent with the City stormwater regulations. Ptanned Actions shall implement the City's adopted Sunset Area Surface Water Master Plan,and assaciated street frontage improvements,and be consistent with the City stormwater regulations in effect at the time of application.Planned Actian applicants shall also demonstrate compliance with RMC 4-1-184 Charges far Equitable Share of Public Works Facilities. Nexus Ciry of Renton Comprehensive Plan RMC 4-3-05Q Critical Areas Regulations RMC 4-4-030 Development Guidelines and Regulations-General RMC 4-6-030 Drainage (Surface Water)Standards RMC 4-6-060 Street Standards 4. Piants and Animals Significant Impacts Tabie 8. Piants and Animais Significant impacts Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea Construction Individual redevelopment Same as Planned Action Study Area Pianned Action Ordinance 20 Attachmenk B Mitigation Documeni ORQIPUANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea projects would result in short- term loss of vegetation caver, along with noise and activity levels that would result in little ar no use of the constructian areas by wildlife during the period af construction. Redevetopment actions would be required to comply,during construction,with City regulations requiring temporary erosion and sedimentation controls to prevent water quality impacts from work site starmwater runoff. Q erations Itedeveloprnent activities that Same as Planned Action Study Area would be facilitated under the planned action ordinance would have a limited effect on plant or wildlife habitat in the Planned Actian Study Area.New development being designed as Low Impact Development{LID is likely to result in a measurable decline in total vegetated area,accompanied by a measurable improvement in piant diversity and quality of the remaining habitat. Green connections and urban forestry plans affset to some degree by greater redevelapment,the net result is likely to be a reduction in habitat connectivity and a decline in total vegetated area, albeit with some improvement in plant diversity and quality of the remaining habitat. Largeiy due ta the absence of irnpacts on special-status species,effects on wildlife would be less than significant. ndirect Planned Action Alternatives Same as Planned Action Study Area would result in an indirect impact on plants and wildlife by contributing to a substantial increase in the human population within the area.This can be expected ta result in effects such as increased wildlife martality due to road Pldnned ACtion OrdinanGB 21 Attachment B:Mit3gation Document ORDINANCE NC}. 5$13 ATfACNMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea kill and predation by pets,and reduced wildlife diversity due ta increases in opportunistic species such as starlings,crows, and rats.These indirect impacts can be expected to result in reduced numbers,vigor,and diversity of plant and wildli e species. The stormwater commitments incarporated in Planned Action Alternatives would be sufficient ta avoid substantial impacts on aquatic habitats and fish. Cumulative No impact No impact Unavoidable Adverse Impacts No significant unavoidable adverse impacts would occur for plants and animals under any alternative. Mitigation Measures With implementation of propased stormwater features or standards,no mitigatian is required. Nexus City of Renton Comprehensive Plan RMC 4-6-030 Drainage(Surface Water) Standards RMC 4-3-050 Critical Areas Regulations RMC 4-4-030 Develapment Guidelines and Regulations-General RMC 4-4-130 Tree Retention and Land Clearing Regulations 5. Energy Significant Impacts Table 9. Energy Significant Impacts Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea Construction During construction,energy Same as Planned Action Study Area would be consumed by dernolition and reconstruction activities.These activities would include the manufacture of construction materials,transport Platlned ActiOn Ordifldn[Q 2z Attachment B:Mitigation Document CJRDINANCE N4. 5813 ATTACHMENT B Patential Sunset Terrace Type of Impact Planned Action Study Area Redevelapment Subarea of construction materials to and from the construction site,and operation af machinery during demolitian and construction. Operations Energy tJsage:Study Area The annuai energy usage is The annual energy usage is and Subarea estimated at 255,845 ta 275,529 estimated at 22,33$to 43,654 million British thermal units rnillion British thermal units(Btu). Btu). Indirect and Cumulative Energy Usage:Subarea,With high levels of transit- With high levels of transit-oriented Study Area,and Region oriented and high-density and high-density development the develapment the Planned Actian Planned Actian Alternatives would Alternatives wauld provide the pravide the greatest estimated greatest estimated regional regianal energy usage reduction for energy usage reduction for the the subarea compared to the Na study area compared to the No Action Alternative: 1,145 to 3,624 Action Alternative:26,3$3 to million Btu, 29,194 millian Btu. Unavoidabfe Adverse Impacts Additional energy would be consumed and would contribute to increases in demand associated with the growth and development af the region.As described in the Utilities Element of the City Comprehensive Plan,it is anticipated that existing and planned infrastructure of affected energy utilities could accommodate growth,Energy canservation features would be incorporated into building design as required by the current City building codes. For the Potentiat Sunset Terrace Redeveiopment Subarea,HUD encourages public housing authorities such as RHA to use Energy Star,renewable energy,and green construction practices in public hausing.As such,no significant unavoidable adverse impacts an energy use are anticipated, Planned Action(7rdinancE 23 Attacfiment e:Mitigation Document ORDINANCE NtJ. 5813 ATTACHMENT B Mitigation Measur s Table 10. Energy Mitigation Measures Planned Action Study Area Potentia]Sunset Terrace Redevelapment Subarea Although the grawth and development wauid In addition to the mitigation measures described far result in increased energy demand in the the Planned Action Study Area,according to the King Planned Action Study Area under all of the County proposed GHG reduction regulation,energy alternatives,expanding the beneficial transit- reductions can be provided with the implementation ariented development and high-density of the foilowing basic requirements of the American hausing development within the study area Society of Heatin,g,Refri,gerating and Air-anditianing would reduce regianal energy usage. Engzneers Advanced&uildin,gs Core Performance Guide Therefare,all alternatives would provide a for residential and non-residential building in the net benefit rather than adverse impact with subarea: regards to energy usage.Hawever,to further 3pola energy reduction for residential dwelling reduce energy consumptian,the City shall that are 50p/o of average size;and 15%energy encourage future developers ta implement reduction for residential dwelling that are 75%of additional trip-reduction measures and average size;and energy conservation measures.For example, energy and GHG reductions can be achieved . 12%energy reduction for office,school,retail, through implementation of the following and public assembly buildings that are smaller energy canservatian techniques or equivaient than 100,004 square feet in floor area. approaches. An energy reduction of 12Q/o can be achieved by implementing sufficient strategies established by the Northwest Energy Star Homes program for multifamily residential buildings.The Northwest ENERGY STAR I-Iomes pragram(U.S.Enviranmental Pratection Agency 2010)is designed to help buiiders construct energy-ef cient homes in Washington,Oregon,Idaha,and Montana to meet energy-efficiency guidelines set forth by the EPA. An energy reduction of 10%would comply with Seattle Energy Cade for non- residentia]buildings. See also Air Quality mitigation measures.The City shall require developmem applicants to consider trip-reduction measures and energy conservation,and as part of their application explain what reductian measures are included and which ones are not ineluded(based an that are part of Table 6 ar Tabie 10).The City may condition Planned Action applications ta incorporate feasible trip reduction and energy conservatian measures. Nexus City of Renton Comprehensive Plan Planned Action Ordinance 24 Attachment B:Mftigation Document oRai van c vo. s1 ATTACHMENT B RMC 4-5-051 Washington State Energy Code Adopted 6. Noise Significant Impacts Tabie 11. Noise Significant Impacts Fatentia]Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea Construction Development in the study area Same as Planned Action Study would require demolitian and Area canstruction activity,which would temporarily increase noise levels at residences close to the develapment site.This type of activity could cause annayance and speech interference at outdoor tocations adjacent to the construction sites,and could cause discernible noise. Operatians Noise from New Uniess properly controiled, Same as Pianned Action Study Commercial Operations rnechanical equiprnent(e.g.,Area rooftop air conditioning units) and trucks at loading docks af affice and retail buildings in the study area could cause ambient noise levels at nearby residential housing units to exceed the City naise ordinance timits. lndirectand Cumulative Noise from Increased For most residents adjacent to Development wauld result in Traffic:Praposat with roadways in the study area, noise increase from vehicles Future Traffic Levels increased traffic wauEd result in traveling on NE Sunset the greatest increase in ambient Boulevard and locat streets The noise]evels,caused by moving estimated day-night naise levels traf c and vehicles idling at from NE Sunset Boulevard at intersections.Development the adjacent buildings indicates would result in noise increase they wauld be exposed to from vehicies traveling an NE "normaliy unacceptable"noise Sunset Boulevard and local levels exceeding U.S. streets.Department of Housing and Urban Develaprnent's(HUD's) outdoor day-night noise criterion of b5 dBA.The naise levels at these first raw residential dwellings currently exceed the HUD noise criterion and wauld continue to exceed Planned Action Ordinance 25 Attathment B:Mitfgation Qocument ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea the criterion under Planned Action Atternatives. Unavoidable Adverse Impacts No significant unavoidable adverse constructian or operational traffic noise impacts are anticipated in the Planned Action Study Area with the implementation of mitigation measures noted below.No significant unavoidable adverse traffic ndise impacts are anticipated at residences alang NE Sunset Boulevard in the Planned Action Study Area per WSDOT criteria,because the noise increase caused by NE Sunset Boulevard traffic is less than the WSDOT"substantial increase"impact threshald, Partians af the Potential Sunset Terrace Redevelapment Subarea,even under existing conditions and the Na Actian Alternative,would be deemed narmally unacceptable under the HUD noise criteria withoat implementation of noise attenuation mitigation,due to traffic noise from the adjacent street(NE Sunset Boulevard).Na significant unavoidable adverse noise impacts are anticipated in this subarea,if the noise control measures noted below are implemented ta reduce anticipated future traffic noise to levels suitable for residential uses under the HUD criteria. Mitigation Measures Table 12. Noise Mitigatian Measures Planned Action Study Area Potential Sunset Terrace Redevelopment Subarea Constructian Naise Mitigation measures described in the Planned To reduce constructian noise at nearby Action Study Area wouid aiso apply to this receivers,the failowing mitigatian measures subarea. shall be incorporated by Planned Action Site design approaches shall be incorporated to applicants inta construction plans and reduce potential noise impacts including the contractor specifications. following. Locate stationary equipment away from Concentrating park and apen space uses away receiving properties. from NE Sunset Boulevard. Erect portable noise barriers around loud • Where park and open space uses must be stationary equipment lacated near sensitive located near NE Sunset Boulevard,avoiding receivers. activities that require easily understood conversation(e.g.,instructianal classes),or Limit construction activities to between 7:OQ flther uses where quiet canditions are a.m.and 10:00 p.m.to avoid sensitive required for the primary function of the nighttime hours. activi t3'• Turn off idling canstruction equipment. Allowing for balconies on exterior facing units Require contractors to rigorously maintain only if they do not open to a bedroam. all equipment. According to HUD noise guideboak,noise Train construction crews ta avoid attenuation fiom various building materials are unnecessarily loud actions(e.g.,dropping calcuiated using saund transmission class(STC) bundles of rebar onto the ground or ating.Although the standard canstruction dragging steel plates across pavement)near PPraaches can normally achieve the STC rating of noise-sensitive areas. more than 24 dBA as demonstrated in Final EIS Appendix E,the City shall reGuire a 5TC rating of New Commerciat Operation Noise 30 dBA reduction for these first row residential The City shall require all prospective future Pianned Action Ordinance 26 Attachment 8:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B P anned Action Study Area Potential Sunset Terrace Redevelopment Subarea developers to use low-noise mechanical dwellings because the HUD noise guidebook shows equipment adequate to ensure compliance with that the sound reduction achieved by different the City's daytime and nighttime noise ordinance techniques may be a little optimistic3. limits where commercial uses are abutting residential uses and where there is a potential to exceed noise ordinance limits.Depending on the nature of the proposed development,the City may require the developer to conduct a noise impact study to forecast future noise levels and to specify appropriate noise control measures. Compliance with the noise ordinance would ensure this potential impact would not be significant. Traffic Noise Mitigation Although traffic noise is exempt from City noise ordinance,based on site-specific considerations, the City may at its discretion require the new development to install double-pane glass windows or other building insulation measures using its authority under the Washington State Energy Code(RMC 4-5-040). Nexus City of Renton Comprehensive Plan RMC 4-4-030 Development Guidelines and Regulations—General RMC 4-4-060 Grading,Excavation and Mining Regulations RMC Title 8 Chapter 7 Noise Level Regulations 7. Environmental Health Significant Impacts Table 13. Environmental Health Impacts Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea Construction Potential construction impacts Existing subsurface indude releasing existing contaminations have not been contaminants to the environment identified on the redevelopable by ground-disturbing or properties and,therefore,are not dewatering activities, expected to be encountered encountering underground during construction.Hazardous storage tanks(USTs)or leaking building materials such as lead- USTs,generating hazardous based paint and asbestos- building materials that require containing materials(ACMs) 3 HUD noise guidebook,Chapter 4,page 33"...use the STC ratings with a bit of caution and remain aware of the possible 2-3 d6 overstating that you may get with the STC rating system." Planned ACtiOn OrdinanCe z Attachment B:Mitigation Document ORDINANCE NO. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea special disposal,and accidentally could be generated from releasing hazardous substances. demolition of the existing Sunset Terrace buildings.If there are lead-based paints or ACMs at the complex,appropriate permits and precautions would be required. Accidental release of hazardous substances during construction could still occur as in all construction projects. Operations If development occurs on No impact contaminated sites,where appropriate clean-up measures were not completed or residual contaminations were present, then there is a potential risk to public health for people using the site. lndirect No impact No impact Cumulative No impact No impact Unavoidable Adverse Impacts No significant unavoidable adverse impacts are identified at the programmatic level throughout the Planned Study Area or for the Sunset Terrace Redevelopment Subarea for any of the studied alternatives.Contaminated sites would be avoided during project design when possible; implementing the mitigation approaches described below would minimize or eliminate adverse effects on human health and the environment. Mitigation Measures Table 14. Environmental Health Mitigation Measures Planned Action Study Area Potential Sunset Terrace Redevelopment Subarea Since encountering unreported spills or The construction and operation mitigation unreported underground fuel tanks is a risk measures identified for the Planned Action Study when performing construction,contractors Area are applicable to the subarea. shall be required to provide hazardous materials awareness training to all grading and excavation crews on how to identify any suspected contaminated soil or groundwater,and how to alert supervisors in the event of suspected contaminated material.Signs of potential contaminated soil include stained soil,odors,oily sheen, or the presence of debris. Contractors shall be required to implement a contingency plan to identify,segregate, and dispose of hazardous waste in full Pldnned ACtiOn OfdlnanCe Z$ Attachment B:Mitigation Document RDINANCE NC}. 5813 ATTACHMENT B Planned Action Study Area Potential Sunset Terrace Redevelapment Subarea accordance with the Model Toxics Cantral Act(MTCA)(WAC 173-340)and the Dangerous Waste(WAC 173-303) regulat'sans. Contractors shall be required to develop and implement the Stormwater Pollution Preventian Plan,BMPs,and ather permit canditians to minimize the potential for a release of hazardous materials to soil, groundwater,or surface water during construction. Contractors shall be required to follow careful construction practices to protect against hazardous materiais spil)s from routine equipment operatian during construction;prepare and maintain a current spill prevention,cantrol,and countermeasure plan,and have an individual on site designated as an emergency coardinator;and understand and use proper hazardous materials starage and handling procedures and emergency procedures,including proper spill natification and response requirements. All asbestos-containing materials(ACM) and lead-based paint wili be identiFed in structures priar to demolition activities in accordance with 24 CFR Part 35.lf ACM or lead-based paint is identified,appropriately trained and licensed personnel will contain, remove,and properly dispose of the ACM and/or lead-based paint materiat according to federal and state regulatians prior to demolition af the affected area. If warranted,contractors shall conduct additional studies to]ocate undacumented underground starage tank(USTs)and fuel lines before construction of specific development projects(areas af concern include current and forrner commercial and residentia]structures)and will permanently decommission and properly remove USTs from project sites before commencing general construction activities. Priar to acquisition of known or potentially contaminated property,the City shalt require apprapriate due diligence be performed ta identify the presence and extent of soil or groundwater Planned Action Ordinance 29 Attachmenk 8:Mitigation pocument QRDINANCE N0. 5813 ATTACHMENT B Planned Action Study Area Potential Sunset Terrace Redevelapment Subarea contamination.This can help to prevent or manage liabilities for any long-term clean- up activities that might be angoing during project aperations.If contaminatian is discovered,the project proponent will cornply with all state and federal regulations far contaminated sites. Nexus City of Rentan Comprehensive Plan RMC 4-4-030 Development Guidetines and Regulations-General RMC Title 4 Chapter 5 Building and Fire Prevention Standards 8. Land Use Significant Impacts Tabte 15, Land Use Impacts Potential Sunset Terrace Type of Impact Ptanned Action Study Area Redevelopment Subarea Construction The incremental nature of Same as Planned Action Study develapment over the planning Area period would minimize the number af nearby residents exposed to temporary construction impacts including dust emissions,noise, construction traffic,and sporadic interference with access to adjacent residences and businesses. Operations Land Use Patterns Planned Action Alternatives Planned Action Alternatives would provide more than 2,300 to would provide about 266-554 2,500 dwelling units and 1.2 to mare dwelling units than existing 1.3 million square feet of conditions in a mixed-use cornmercial space compared ta development that integrates existing conditions. comrnercial and civic spaces. Redevelopment would pravide mare cornmercial development than residential development. This aiternative would also pravide more than two times as many residential dwellings as currently exist in the study area. Plans and Policies Planned Actian Alternatives Planned Action Alternatives pravide the greatest degree of provide the greatest degree of P(dllned ACtion OrdilldnC@ 30 Attathment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea consistency among the consistency with the City's land alternatives with the City use element goals and policies of Comprehensive Plan goals, all alternatives by promoting the objectives,and policies by redevelopment of the Sunset implementing the development Terrace public housing types envisioned in the City's land community.It also does more use and zoning designations than other alternatives to develop within the study area.Anticipated the Center Village.Development growth would help the City meet in the subarea under this its 2031 housing and employment alternative has a similar targets. consistency as the study area for Public investments would need to other City goals and policies, be accounted for in amendments providing a greater degree of to the City's Transportation and consistency with those goals and Capital Facilities elements. policies than other alternatives. ndirect and Cumulative No indirect or cumulative land Redevelopment of the subarea use impacts are anticipated under this alternative would outside the study area.The City serve as an incentive for other applies its policies and redevelopment opportunities development regulations to create near the study area. a planned land use pattern. Density is most intense at the center of the study area and least along its boundaries with single- family residential land use patterns;it is unlikely to alter patterns or plans along the edges of the study area.The City will,as part of its regular comprehensive plan review and amendment updates,control the monitoring, evaluation,and amendment process. Unavoidable Adverse Impacts Although intensification of land uses in the Planned Action Study Area,including the Potential Sunset Terrace Redevelopment Subarea,would occur and density would increase,this change would be consistent with applicable plans,zoning,and land use character. Plan consistency can be addressed by Comprehensive Plan amendments using the City's legislative process.Therefore,there would be no significant adverse impacts. Mitigation Measures Table 16. Land Use Mitigation Measures Planned Action Study Area Potential Sunset Terrace Redevelopment Subarea Under all alternatives,the City shall require Construction mitigation would be the same as planned action applicants to implement described under the Planned Action Study Area. appropriate construction mitigation measures, The City and RHA should coordinate on future including but not limited to dust control and Pldnned ACtiOn OfdindnCe 31 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Planned Action Study Area Potential Sunset Terrace Redevelopment Subarea construction traffic management. Sunset Terrace redevelopment and Planned The City shouid make efforts to minimize Action Study Area streetscape improvements to property acquisition that affects buildings as part ensure that property acquisition that affects of its refinement of study area streetscape designs buildings is minimized. while balancing Complete Streets principles. The City shall require construction plans to: As part of the Planned Action Ordinance adoption Locate the majority of the most intensiveprocess,the City should amend its Comprehensive non-residential development along or nearPlan's Transportation and Capital Facilities NE Sunset Boulevard,where possible. elements to ensure that planned public investments and their funding sources are Implement proposed open space and accounted for and programmed. landscape features to offset the proposed intensification of land uses on the site. Provide new opportunities for public open space area. As part of site design,emphasize transitions in density,with less intense densities where abutting lower-intensity zones. Nexus City of Renton Comprehensive Plan RMC Title 4 Chapter 2 Zoning Districts—Uses and Standards 9. Socioeconomics Significant Impacts Table 17. Socioeconomics Impacts Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea Construction Construction activities could The demolition of the Sunset temporarily increase congestion Terrace complex to allow for the and reduce parking,local access subarea redevelopment would for businesses and residents,and require the relocation of the access near the construction tenants. activities,which could negatively Moreover,the relocation of the affect businesses;however, tenants could affect some local businesses located close to businesses during construction,if construction activities could the tenants are relocated outside experience an increase in revenue of the immediate area; however, from spending by construction since the total number of workers. relocations represents a small portion of the overall population any impact would likely be small in scale. Operations The higher number of dwelling The Planned Action Alternatives units and jobs would result in would increase dwelling units and greater intensities in development jobs by 266-554 net dwelling Planned ACtion OfdindnCe 32 Attachment B:Mitigation Document ORDINANCE NO. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea and economic benefits.units and 79- 117 jobs. The Improvements in the streetscape subarea would be developed with along NE Sunset Boulevard and new park,street,and civic the other civic and infrastructure improvements that would improvements would make the promote a healthy and walkable study area more desirable to neighborhood. investment,which could lead to additional opportunities for employment as more businesses are attracted to the study area. The facilities that would be added under Alternative 3 include a family village and a wider reconstruction of NE Sunset Boulevard.The family village would include housing,education, recreation,and supportive services that would be designed to promote a healthy and walkable neighborhood. lndirect Construction spending would Increased spending is anticipated result in positive indirect effects with the mixture of affordable and on the economic elements of market-rate units,which would employment and income in the result in positive impacts on the study area and the regional businesses in the area as well as economy as businesses that local tax revenues. support the construction effort would likely see increased spending. The additional public and private investment and associated economic benefits would be greater due to the increased spending. Cumulative Cumulative effects would be As the area changes and new positive with the addition of new housing is provided,no existing development that would continue public units would be lost and to enhance the area and continue improvements in the to improve the neighborhood neighborhood would likely vitality. continue as new developments are constructed. Unavoidable Adverse Impacts No long-term significant unavoidable adverse impacts are anticipated. Planned Action alternatives would encourage new development in the both the Planned Action Study Area and the Potential Sunset Terrace Redevelopment Subarea that would result in beneficial changes to the socioeconomic conditions. Under Planned Action Alternatives,relocation of the tenants of the Sunset Terrace complex would result in short-term impacts;however,these impacts would be mitigated.The creation of new jobs Planned ACtion Ordindnce 33 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B and spending in the subarea during construction of new developments would result in short-term benefits. Mitigation Measures Table 18. Socioeconomics Mitigation Measures Planned Action Study Area Potential Sunset Terrace Redevelopment Subarea Mitigation measures to minimize dust,noise, In addition to mitigation measures described for aesthetics,and transportation impacts during the Planned Action Study Area,the following construction are identified in Sections 2,6, 12, mitigation measures apply: and 14,respectively,of this Mitigation Document. . Public housing tenants shall be provided These measures would address many of the relocation assistance under the Uniform construction-related impacts that could Relocation Act. negatively affect the study area businesses. RHA should consider phased demolition and In addition,with the reconstruction of NE Sunset reconstruction to minimize the need to relocate Boulevard,or with any new development,if all the residents at the same time,or the new access to businesses is affected,the following affordable housing development could be measures should be addressed by the City or constructed prior to demolition to provide WSDOT: opportunities to relocate tenants within the Provide detour,open for business,and other subarea. signage,as appropriate. Provide business cleaning services on a case- by-case basis,as needed. Establish promotions or marketing measures to help affected businesses maintain their customer base during construction. Maintain access,as much as possible,to each business and,if access needs to be limited, coordinate with the affected businesses. Mitigation measures to address indirect impacts on housing affordability are addressed in Section 10 of this Mitigation Document. Nexus City of Renton Comprehensive Plan 10. Housing Significant Impacts Table 19. Housing Impacts Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea Construction Construction of commercial, Construction of residential and residential,and civic uses in the civic uses would create temporary study area would create noise,dust,and construction temporary noise,dust,and traffic,which would affect Plann2d ACtion OfdindnCe 34 Attachment B:Mitigation Document ORDINANCE NO. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea construction traffic,which would adjacent residents to the subject affect current residents. properties. Operations The Planned Action Alternatives In this subarea,110 public assume 40%of the study area housing and duplex dwellings acreage would infilt or redevelop. would be eliminated.There would This would result in the greatest be a 1:1 replacement of public number of dwellings replaced at housing units on site and in the 299. Planned Action Study Area. The Planned Action Alternatives The number of units added would would add up to approximately be 266-554 above existing 2,339 to 2,507 new dwellings.dwellings,for a total of 376-664 In the study area there is a units.About three quarters of the potential for additional market units would be affordable or public, rate dwellings as well as and another approximate quarter affordable and public dwellings. Would be market-rate dwelling Most new units would be units. multifamily. lndirect Increased housing could increase The potential for residents to help local resident spending at support local businesses as well businesses in the study area,and as to create a demand for services could also create an increased is similar to the Planned Action demand for parks and recreation, Study Area. public services,and utilities. Cumulative Growth in the study area would The support of the new dwellings be consistent with the City's to assist the City in meeting Comprehensive Plan and would growth targets is similar to the contribute to meeting growth Planned Action Study Area. targets for the City's next Comprehensive Plan Update for the year 2031. Unavoidable Adverse Impacts Housing in the Planned Action Study Area would likely redevelop to some degree to take advantage of adopted plans and zoning.However,the alternatives would allow for the construction of new dwelling units to replace those that are eliminated.Lower-cost housing could be replaced with more costly housing. Implementation of City regulatory incentives and use of federal,state,and local housing funds and programs could reduce potential affordability impacts.Through its regular Comprehensive Plan review cycles,the City could monitor housing trends in the neighborhood and adapt measures to promote affordability. During construction and in the short-term,residents would be subject to construction activities and the tenants of the Sunset Terrace complex would be required to relocate during demolition and construction. However,relocation assistance mitigation measures for RHA units would mitigate impacts. Planned ACtion OrdinanCe 35 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATfACHMENT 8 Mitigation Measures Table 20. Housing Mi#igation Measures Patentiai Sunset Terrace Redevetapmer t Planned Action Study Area Subarea Renton Municipai Cade(RMC)4-4-Q30(C) Construction mitigation would be as described identifies construction hnurs intended to address for the Planned Action Study Area. noise in sensitive time periods.See Section 6, RHA has cammitted to replacement hausing for Noise,of this Mitigation Document regarding other the Sunset Terrace public housing units at a 1:1 noise mitigatian measures for constructian ratio,consistent with the existing proportion of periods. units by number af bedrooms.Such replacement When federal funds are being used for a praposal, hausing could occur on site and jar off site. displaced tenants shall be offered relocation During the time replacement hausing is under assistance in compliance with the Uniform construction,Section 8 vouchers,or equivalent Relocation Assistance and Real Property measures,shall be used to relocate tenants. Acquisitions Policies Act of 1970,as amended. The Ciry and RHA should apply for federa3,state, and local funding programs described in Draft EIS Section 3.2Q,Hausing,ta promote new housing appartunities for low and very low-income housing. RHA shauld establish a local preference far rental assistance.For example,RHA could establish a priority list far Sectian 8 vouchers for displaced low-income tenants in the Planned Action Study Area(in addition to the relocation assistance to he provided by RHA to the Sunset Terrace residents). llnit replacement and relocation assistance for the family village would be the same as described for the Patential Sunset Terrace Redevelapment Subarea. Nexus City of Renton Comprehensive Plan RMC Title 4 Chapter 2 Zoning Districts-Uses and Standards RMC 4-4-030 Development Guidelines and Regulations-General 11. Environmentallusfiice Significant Impacts Table 21. Environmentallustice Impacts Potentia]Sunset Terrace Type of Impact Planned Action Study Area Redevetopment Subarea Constructian Residents near constructian The demolition of the Sunset activities would likely be affected Terrace camplex and construction by temporary noise,dust,and of the proposed conceptual plans visual impacts due to wauld require the relocatian of Planned Action Ordinance 36 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea construction;these impacts would the tenants of the Sunset Terrace be short-term in nature.The complex likely through Section 8 poputation of the study area is vouchers.Because the tenants are predominately non-minority and low-income and predominately non-low-income and any negative minority,this would constitute a impacts would likely occur on greater impact on these these populations to a greater populations than other degree than the minority and low- populations. income populations. Operations Residential,commercial,and Planned Action Alternatives recreational development and would have a number of beneficial civic and infrastructure effects on minority and low- improvements under Planned income populations in the Action Alternatives would subarea,including the improve the overall redevelopment of the existing neighborhood,making it a more dwelling units,construction of cohesive and desirable place to additional units,transportation live for all populations in the improvements,and the addition community,including minority of other community facilities(i.e., and low-income populations. senior day health,library,parks). The family village would be These changes would result in beneficial for all populations in improvements to public health the Planned Action Study Area, and to the aesthetics of the area. but these benefits could accrue to These would all improve a greater degree for minority and community cohesion for subarea low-income populations due to residents. the close proximity,especially for those without access to a vehicle. lndirect The introduction of new retail and Housing types and affordability commercial space within the would be more varied.New retail study area would increase and commercial space wand employment opportunities.These provide new employment opportunities would benefit all opportunities could be seen as study area populations,but could more beneficial to subarea benefit minority and low-income residents who may be populations to a greater degree. unemployed or not have a their The Planned Action Alternatives own vehicle and would,therefore, would increase the variety of benefit more from the proximity. residential unit types and affordability levels would reduce the concentration of low-income households in the subarea,and thereby reduce or eliminate some of the social consequences of such concentrations. Cumulative Cumulative impacts would Adverse impacts are not primarily be beneficial.As the anticipated.New dwelling units area continues to redevelop with would be affordable,public,and new investments,public and market-rate units.The beneficial private,it would become more cumulative impacts identified desirable for the residents and under the Planned Action Study Planned ACtiOn OrdinanCe 3 Attachment B:Mitigation Document RDINANCE Nt}. 5813 AITACHMENT B Pc tential Sunset Terrace Type of Impact Planned Action 5tudy Area Redevelopment Subarea would continue to create new Area would be similar. jobs.The new development and additian of more market-rate units could cause the study area to become less affordable to lower-income papulations,which could result in these populations needing to relocate outside of the study area. Unavoidabie Adverse impacts There are no long-term significant unavoidable adverse impacts related to environmental justice. The Planned Actian alternatives would result in primarily beneficial impacts associated with new dwelling units,new civic facilities and parks,improvements in nonmotorized transpartation,and new employment opportunities in the surrounding area. During construction and in the shart-term residents would be subject to construction activities and the tenants af the Sunset Terrace complex would be required to relocate during demolition anc! constructian.However,construction mitigation and relocatian assistance mitigation measures(for the RHA units)would minimize irnpacts. Mitigation Measures Table 22. Enviranmental Justice Mitigatian Measures Planned Actian Study Area Patential Sunset Terrace Redevelapment Subarea There are no specific mitigation measures related Mitigation measures during constructian include ta environmental justice during constructian or the need far replacement housing far the aperation.During construction,mitigation residents of Sunset Terrace.It is likely that the measures related to noise,dust,traffic congestion, tenants would be relocated under a potential and visual quality shall be applicable to all Sectian 8 vaucher strategy during construction. populations.These measures are described in See Section 9,Socioecanornics,of this Mitigation Sections 2,6,12,and 14,respectivety,of this Document. Mitigation Document. Nexus City of Renton Comprehensive Plan RMC 4-4-Q30 Development Guidelines and Regulations—Genera] 12. aestnet cs Significant Impacts Table 23. Aesthetic Impacts Potentiai Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea Pldnned ActiOn OfdillBnG2 38 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea Construction The demolition of existing Same as Planned Action Study structures and construction of Area new buildings would expose nearby residents to visual impacts,including dust,the presence of construction equipment,stockpiles of construction materials,localized increases in vehicular traffic,and on-site construction activities.For each alternative,these activities would occur sporadically at various locations throughout the Planned Action Study Area,would be localized to the construction site,and would be temporary in nature. Operations Visual Character The extensive public investment The visual character of the under the Planned Action Potential Sunset Terrace Alternatives would result in Redevelopment Subarea would widespread changes to the visual change from its current state to a character of the Planned Action pedestrian-oriented community Study Area affecting about 40%of with a mix of residential,ground- parcel acres.Private development floor commercial,and community would take full advantage of the uses linked by public spaces and current development regulations, landscaped pedestrian pathways. resulting in a transition to a The Preferred Alternative concept mixed-use,pedestrian-oriented would focus less residential neighborhood. development in the subarea than The application of adopted design Alternative 3,making room for a standards as new construction larger neighborhood park. gradually replaces older buildings would result in an overall improvement of the visual environment in the Planned Action Study Area. Height and Bulk The subarea would experience Building height and bulk within moderate increases in height and the Potential Sunset Terrace bulk over existing conditions. Redevelopment Subarea would Heights would range from two to range from one to six stories. four stories,and buildings would The Preferred Alternative, generally be located closer to the however,would provide much street than under current more park space than Alternative conditions.The tallest building 3,and the Reevaluation heights under the Preferred Alternative more park space than Alternative would occur on these alternatives providing a property zoned Center Village. sense of openness to the Sunset Terrace site.In addition,buildings on the site would be arranged to place 2-story townhomes adjacent Pldnned ActiOn OrdinanCe 39 Attachment B:Mitigation Document ORDINANCE NO. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea to the park on the north and taller multifamily residential buildings along NE Sunset Boulevard and Sunset Lane NE to the south. Shade and Shadow Because heights in the Planned Taller buildings along NE Sunset Action Study Area would Boulevard would cast longer generally increase,shading effects shadows on the interior of the would also become more subarea to the north,potentially pronounced,though only to a shading sidewalks along Sunset moderate degree.Increased Lane NE.Dependent on final building heights within the design,building may potentially Planned Action Study Area could shade sidewalks along Sunset result in increased shading of Lane NE and Glenwood pedestrian areas and public Avenue NE at various times of the spaces,particularly along day. NE Sunset Boulevard,which is With the Reevaluation Alternative likely to see some of the most or Preferred Alternative,the intense commercial and mixed- increased size of the central park, use development. as well as the placement of 2- story townhomes adjacent to the park,reduces the potential for adverse shading effects compared to Alternative 3. Indirect/Cumulative While redevelopment of the Redevelopment of the Sunset public facilities discussed under Terrace housing facility would be the various alternatives would be a localized action,but additional a coherent effort,private private development is development throughout the anticipated to occur in response study area would occur to this public investment,and piecemeal.Individual private each private development project developments are likely to be of would contribute to the overall higher density,greater height,and transformation of the area's a different architectural style than aesthetic character. existing development,and have the potential to create temporary aesthetic conflicts where they are located adjacent to older structures.Over time,as more properties redevelop,the temporary conflicts would be less frequent and less noticeable. Unavoidable Adverse Impacts With the application of adopted development regulations and recommended mitigation measures, no significant unavoidable adverse aesthetic impacts are anticipated. Planned ACtion OfdindflCe 40 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Mitigation Measures Table 24. Aesthetic Mitigation Measures Potential Sunset Terrace Redevelopment Planned Action Study Area Subarea In both the Planned Action Study Area and Potential See Planned Action Study Area. Sunset Terrace Redevelopment Subarea,mitigation Current city design standards address building measures will be necessary to minimize impacts modulation and roofline variation and are associated with increased height,bulk,and shading. recommended for application in the Future development occurring under any of the Reevaluation/Addendum. alternatives shall conform to the Renton Municipal Code design standards,including but not limited to the following: Urban design standards contained in RMC 4-3- 100, Residential Design and Open Space Standards contained in RMC 4-2-115,and Lighting Standards contained in RMC 4-4-075. As described in RMC 4-3-100B3,portions of the Planned Action Study Area do not currently lie within an established Urban Design District,most notably those properties north of NE 16th Street and west of Kirkland Avenue NE,where the family village proposed under the Planned Action A ternatives would be located.To ensure that future redevelopment exhibits quality urban design,the City should consider either including this area in Design District D or creating a new design district for this purpose.Prior to the enactment of new design standards,the City may condition development north of NE 16th Street to meet appropriate standards of Design District D in RMC 4- 3-100. Nexus City of Renton Comprehensive Plan RMC Title 4 Chapter 2 Zoning Districts-Uses and Standards RMC 4-3-100 Urban Design Regulations RMC 4-4-075 Lighting,Exterior On-Site 13. Historic/Cultural Significant Impacts Table 25. Historic/Cultural tmpacts Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea Planned ACtiOn OrdinanCe 41 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea Construction Typical project impacts that could No significant cultural resources disrupt or adversely affect are known to exist in the Potential cultural resources in the Planned Sunset Terrace Redevelopment Action Study Area include Subarea. demolition,removal,or substantial alteration without consideration of historic and archaeological sites and/or features. Operations,lndirect,and Development could occur on or Future development in the Cumulative lmpacts near parcels in the Planned Action subarea would have no impact Study Area that contain any known National Register of previously identified or unknown Historic Places(NRHP)-eligible cultural resources.This archaeological or historic development would likely involve resources,and the likelihood of ground disturbance and impacts on unknown cultural modifications to buildings and resources is considered low. structures,which could result in a potentially significant impact on cultural resources.Because of the potential to impact unknown cultural resources,a detailed review of potential impacts on cultural resources would be required on a project-specific basis. Unavoidable Adverse Impacts The impacts on cultural resources caused by new development associated with any alterative could be significant and unavoidable,depending on the nature and proximity of the proposed development project.Implementation of mitigation measures set forth in Draft EIS Section 4.13.2 as amended in the Final EIS would identify potential impacts on cultural resources,at which point measures to reduce them to less than significant could be taken. Mitigation Measures Table 26. Historic/Cultural Mitigation Measures Potential Sunset Terrace Redevelopment Planned Action Study Area Subarea In the event that a proposed development site Since no native"A"horizon was identified at the within the study area contains a building at Edmonds-Glenwood site and throughout the least 50-years of age that is not listed in or Sunset Terrace public housing complex,no determined eligible for listing in the National further archaeological investigations are Register of Historic Places(NRHP)or recommended for these areas.Although a Washington Heritage Register(WHR),the buried,native"A"horizon was identified on project shall be required to undergo review to RHA's Piha site(east of Harrington Avenue NE), determine if the property is considered eligible the potential for an archaeological discovery is for listing. very low.The project should proceed with no further archaeolo ical investigations.If Planned Action Ordinance 42 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Redevelopment Planned Action Study Area Subarea It is recommended that the City adopt a archaeological materials are discovered during historic preservation ordinance that considers ground disturbing excavations,the contractor the identification and treatment of historic shall halt excavations in the vicinity of the find resources listed in or determined eligible for and contact DAHP. listing in the NRHP or WHR,or locally If human skeletal remains are discovered,or if designated.Until such time an ordinance is during excavation archaeological materials are adopted,the City must enter into consultation uncovered,the proponent will immediately stop with DAHP regarding potential impacts on work and notify agencies as outlined in the historic resources in the study area that are Unanticipated Discovery Plan provided in Draft listed in or determined eligible for listing in the EIS Appendix J and as amended by Final EIS NRHP or WHR. Chapter 4(and provided as Attachment 1 of this Exhibit B).If the project would disturb an For future projects that involve significant archaeological resource,the City shall impose excavation in the study area the City must any and all measures to avoid or substantially enter into consultation with Washington State lessen the impact.If avoidance of the Department of Archaeology and Historic archaeological resource is not possible,an Preservation(DAHP)to determine the appropriate research design must be developed likelihood of and recommendations for and implemented with full data recovery of the addressing potential archaeological resources. archaeological resource prior to the It may be necessary to complete archaeological development project.The avoidance of testing prior to significant excavation in the archaeological resources through selection of study area,such as digging for footings or project alternatives and changes in design of utilities.Archaeological project monitoring project features in the specific area of the may be recommended for subsurface affected resource(s)would eliminate the need excavation and construction in high for measuring or mitigating impacts. probability areas. In the event that a future development project in the study area is proposed on or immediately surrounding a site containing an archaeological resource,the potential impacts on the archaeological resource must be considered and,if needed,a study conducted by a qualified archaeologist to determine whether the project would materially impact the archaeological resource.If the project would disturb an archaeological resource,the City shall impose any and all measures to avoid or substantially lessen the impact.If avoidance of the archaeological resource is not possible, an appropriate research design must be developed and implemented with full data recovery of the archaeological resource prior to the development project.The avoidance of archaeological resources through selection of project alternatives and changes in design of project features in the specific area of the affected resource(s)would eliminate the need for measuring or mitigating impacts. Non-site-specific mitigation could include developing an educational program,interpretive displays,and design guidelines that focus on compatible materials,and professional Pldnned ACtiOn OfdindnCe 43 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Redevelopment Planned Action Study Area Subarea publications. Nexus City of Renton Comprehensive Plan 14. Transportation Significant Impacts Table 27. Transportation Impacts Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea Construction Potential impacts that could result Same as Planned Action Study from construction activities Area include increased traffic volumes, increased delays,detour routes, and road closures. Lane closures in both directions of NE Sunset Boulevard could be required during construction roadway improvements associated with the Planned Action Alternatives.This reduction in capacity would likely increase travel times,and may force reroutes through local streets. Operations Traffic Operations At Edmonds Avenue NE and NE Delay times in the subarea could 12th Street LOS F conditions are worsen slightly due to the predicted in both 2015 and 2030. increase in trips generated,but At Harrington Avenue NE and NE intersections would likely operate 12th Street LOS F conditions are better than the LOS D threshold. expected in 2030. Transit At both Edmonds Avenue NE and Same as Planned Action Study at NE 10th Street,expanded bus Area zones in both directions of travel would provide larger waiting areas for transit users and would be conveniently located near residential or retail land uses.Bus zones and existing bus stops could include shelters with adequate lighting and street furniture. Nonmotorized Planned Action Alternatives Same as Planned Action Study include improved nonmotorized Area facilities such as bicycle lanes, sidewalks,and marked Planned ACtion OfdinanCe 44 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT 6 Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea crosswalks.Design elements such as bike route signage,bike storage lockers,and bicycle detection at signalized intersections are included to promote bike ridership and safety. The Preferred Alternative includes a 5-foot-wide eastbound bicycle lane,rather than bicycle lanes in both directions(as in Alternative 3). Sidewalk connections from NE Sunset Boulevard to side streets would be improved, strengthening the connectivity between the residential areas and NE Sunset Boulevard.To improve safety for pedestrians crossing the roadways,the Preferred Alternative includes special paving at crosswalks and intersections. Sustainability The Planned Action Alternatives Same as Planned Action Study score a minimum of 33 with a Area maximum of up to 99 out of 118 points in the Greenroads metric; therefore,the alternatives meet the minimum Greenroads certification level and could achieve the highest level of certification. The Planned Action Alternatives score most strongly in the"Access and Equity"section of the Greenroads evaluation,as improving access for pedestrians, bicyclists,and transit users are important elements of this alternative. The Planned Action Alternatives typically include higher leve(s of improvements or higher quality of improvements such as wider sidewalks,wider planting areas, and special paving. Indirect and Cumulative Growth would increase in Same as Planned Action Study comparison to Comprehensive Area Plan land use estimates;however, the Planned Action Alternatives' operational analysis is based on a model that addresses growth Planned Action Ordinance 45 Attathment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea cumulatively on the City's current and planned roadway system and any operational deficiencies can be mitigated to meet City of Renton thresholds. Unavoidable Adverse Impacts The alternatives are expected to contribute to a cumulative increase in traffic volumes within the study area,which could degrade some roadway operations.The increase in traffic volumes due to activities in the study area is considered unavoidable,but the roadway operation and LOS can be mitigated to meet applicable LOS standards. Mitigation Measures Table 28. Transportation Mitigation Measures Potential Sunset Terrace Redevelopment Planned Action Study Area Subarea Operational Mitigation No permanent mitigation measures are Planned Action applicants shall pay a Transportation recommended within Potential Sunset Terrace Impact Fee as determined by the Renton Municipal Redevelopment Subarea.The intersection Code at the time of payment,payable to the City as operations under action alternatives are specified in the Renton Municipal Code. expected to be within the LOS D threshold. Planned Action applicants shall provide a traffic During construction,mitigation measures are analysis estimating trips generated by their those described for the Planned Action Study proposed development and demonstrate Area.Flaggers,advance warning signage to conformance with the Planned Action Ordinance trip alert motorists of detours or closures,and ranges and thresholds in Section 3(d) (4)as well as reduced speed zones would likely benefit demonstrate conformance with the City's traffic operations. concurrency requirements in RMC 4-6-070. When demonstrated by an applicant's analysis that operational LOS standards reviewed in the EIS are exceeded at the following locations,intersection improvements shall be made by planned action applicants as appropriate to meet LOS D and in conformance with the City's street standards in RMC 4-6-060: Edmonds Avenue NE and NE 12th Street:an additional southbound left-turn pocket and westbound right-turn pocket would improve operations to LOS E,while added pedestrian-and bicycle-oriented paths or multi-use trails to encourage mode shifts would likely improve operations to LOS D. At the Harrington Avenue NE and NE 12th Street intersection:the eastbound and westbound approaches could be restriped to increase the number of tanes and,therefore,the capacity of the intersection.With implementation,this Planned Action Ordinance 46 Attachment B Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Redevelopment Planned Action Study Area Subarea intersection would improve to LOS D. Construction Mitigation Temporary mitigation during construction may be necessary to ensure safe travel and manage traffic delays.The following mitigation measures shall be implemented prior to or during construction within the Planned Action Study Area. Prior to construction: o Assess pavement and subsurface condition of roadways being proposed for transport of construction materials and equipment. Ensure pavement can support loads. Adequate pavement quality would likely reduce the occurrence of potholes and would help maintain travel speeds. o Alert landowners and residents of potential construction.Motorists may be able to adjust schedules and routes to avoid construction areas and minimize disruptions. o Develop traffic control plans for a11 affected roadways.Outline procedures for maintenance of traffic,develop detour plans, and identify potential reroutes. o Place advance warning signage on roadways surrounding construction locations to minimize traffic disturbances. During construction: o Place advance warning signage on NE Sunset Boulevard and adjacent arterials to warn motorists of potential vehicles entering and exiting the roadway.Signage could include"Equipment on Road,""Truck Access,"or"Slow Vehicles Crossing." o Use pilot cars as dictated by the Washington State Department of Transportation WSDOT). o Encourage carpooling among construction workers to reduce traffic volume to and fi-om the construction site. o Employ flaggers,as necessary,to direct traffic when vehicles or large equipment are entering or exiting the public road system to minimize risk of conflicts between trucks and passenger vehicles. o Maintain at least one travel lane at all times, if possible.Use flaggers to manage Pldnned Action OrdinanC2 47 Attachment B:M tigation Document ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Redevelopment Planned Action Study Area Subarea alternating directions of traffic.If lane closures must occur,adequate signage for potential detours or possible delays should be posted. o Revisit traffic control plans as construction occurs.Revise traffic control plans to improve mobility or address safety issues if necessary. Nexus Renton Comprehensive Plan RMC 4-6-060 Street Standards 15. Parks and Recreation Significant Impacts Table 29. Parks and Recreation Impacts Potential Sunset Terrace f Type of Impact Planned Action Study Area Redevelopment Subarea Construction Construction could temporarily No parks and recreation facilities disrupt pedestrian access to exist in this subarea and no existing park properties.Active construction impacts are construction sites also represent anticipated. opportunities for creative play and attractive adventure for young people in the community. Operations Although there is an increase in With Alternative 3,portions of community park acreage there Harrington Avenue NE right-of- would continue to be a deficiency way within the subarea would be in neighborhood and community converted to 0.25 acres of passive park acreage in the Planned open space. Action Study Area.Deficiencies Under the Preferred Alternative, are less than for the Preferred Sunset Court Park woutd be Alternative than Alternative 3 relocated to the Sunset Terrace which has a similar population Subarea.Additionally,this park but less proposed park facilities. would be expanded from 0.5 acres Ballfield and sport court LOS to 2.65 acres and would have a standards are applied citywide; vacation of Harrington Avenue NE thus a lack of such facilities within similar to Alternative 3. This the Planned Action Study Area or increases the acreage in the Potential Sunset Terrace neighborhood park land for this Redevelopment Subarea does not subarea and the Planned Action indicate an LOS deficiency. Study Area. NE Sunset Boulevard would be improved to include bike lanes, The Reevaluation Alternative also intersection improvements,and relocates Sunset Court Park and Pldnned ACtiOn OfdinanC2 48 Attachment B:Mitigation Document QRDINANCE N0. 5813 ATfACNMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea sidewalks,providing a more would vacate a portion of walkabte corridar and more Harrington Avenue similar to the direct access between residential above alternatives.The size ofthe areas and park land park is the greatest considered at about 3.2 acres. Additionally,a library would be constructed in the subarea. ndirect Indirect impacts are expected to Facility deficiencies in this mostly fall on the City's regional subarea would atso tikely lead to and communitywide parks and spillover demand for aetive recreatian facilities.Far example, piayfields far team sports in ather as the population increases in the parts of Renton as well as in Planned Action Study Area,there surrounding cornmunities. will be a growing deficiency of Neighborhoad and Community Parks.Due to praximity,those demands wauld likely be displaced to nearby regional facilities such as Gene Coulon Park as well as in surrounding communities. Cumulative Increased demands for park and Same as Planned Action Study recreation facilities and services Area generated by the forecast population growth under each of the alternatives would add to thase created by general population growth throughout the Renton community. Unavoidabie Adverse Impacts Under studied alternatives for the Planned Action Study Area and Potential Sunset Terrace Redevelopment 5ubarea,there wauld be an increased demand for parks and recreation facilities. With the application of mitigation measures,no significant unavoidable impacts are anticipated. Mitigation Measures Table 30. Parks and Recreation Mitigation Measures Planned Action Study Area Potential Sunset Terrace Redevelopment Subarea During construction,impacts adjacent to or in With the prevalence of public facilities in the parks within the Planned Action Study Area,such Planned Action Study Area as a whole,and the as an increase in noise,dust,and access addition of a centrai park and a library in the timitations,shall be mitigated as per a Potential Sunset Terrace Redevelopment construction mitigation plan developed by Subarea,there is opportunity to manage the Planned Action applicants and approved by the current facilities in a manner that maximizes ty, their beneficial parks and recreation uses for Planned Action Applicants shall pay a Parks and future population growth.The mitigation Recreation Impact fee as deterrnined by the measures proposed far the Flanned Action Study Area shall a pty to the Patential Sunset Terrace Pldnned ACtion OrdindnCe 49 A#tachment B:Mitigatioo Document ORDINANCE N0. 5813 ATTACHMENT B Planned Action Study Area Potential Sunset Terrace Redevelopment Subarea Renton Municipal Code at the time of payment, Redevelopment Subarea. payable to the City as specified by t he Renton Municipal Code. The following four mitigation measures would help improve the availability or access to parks and recreation facilities in the Planned Action Study Area. The City is initiating a parks,recreation,open space and natural resources plan for completion in 2011.That plan could identify alternative LOS standards and parks and recreation opportunities inside or outside of the Planned Action Study Area that could serve the local population. The City is considering amendments to its development codes that would provide for payment of a fee-in-lieu for required common open space.As proposed,the fee-in-lieu option could be executed when development sites are located within 0.25 mile of a public park and when that park can be safely accessed by pedestrians.The City's package of amendments also includes park impact fees. The City and Renton School District could develop a joint-use agreement for public use of school grounds for parks and recreation purposes during non-school hours.Joint-use agreements between the City and Renton School District could also be used to,at least partially,address the LOS deficiencies in existing recreation facilities. The City could add parks and recreation facilities such as: o The City could convert current public properties no longer needed for their current uses to parks and recreation uses, such as the Highlands Library that is intending to move and expand off site. Draft EIS Figure 4.15-2 shows properties in public use. o The City could purchase private property for parks and recreation use.An efficient means would be to consider properties in the vicinity of existing parks and recreation facilities or where additional population growth would be greatest. Draft EIS Figure 4.15-2 shows locations where future demand could be greater and where the City could focus acquisition efforts. Planned Action Ordinance 50 Attachment B:Mitigation Document 4RDINANCE N0. 5813 ATfACHMENT B Nexus Renton Camprehensive Plan Parks,Recreation,Open Space and Natural Resources Plan 16. Public Services Significant Impacts Table 31. Public Services Impacts Potential Sunset Terrace Type of tmpact Planned Action Study Area Redevelopment Subarea* Construction Police The Renton Police Department Same as Planned Action Study cauld experience an increase in Area calls for service related to construction site theft,vandalism, or trespassing relating to construction. Pire and Emergency Medical Construction impacts on fire Sarne as Planned Action Study Services protection and emergency Area medical services could include increased calls far service related to inspection of construction sites and patential construction-related injuries. Education The McKnight Middle Schaol No impact expansion wauid accur similar to other alternatives.In addition, changes would occur at the Hillcrest F.arly Childhoad Center and the reconfigured Hillcrest Early Childhaad Center would be part of a family village cancept that would include recreation and housing.The expansion of McKnight Middle School is not expected to disrupt student attendance at the campus. Health Care There may be temporary changes Same as Planned Action Study to nonmotorized and motorized Area access to health care services during infrastructure construction(e.g.,NE Sunset Baulevard),but alternative routes wauld be established. Social Services There may be temparary changes Redevelapment of the Sunset to nonmotorized and motorized Terrace housing develapment access to social services during would displace the existing on- infrastructure construction(e.g., site community meeting space Planned Action Ordinance 51 Attachment B:Mit9gation Document ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea* NE Sunset Boulevard),but that is currently used for on-site alternative routes would be social service programs.However, established. the space would be replaced Construction at the Hillcrest Early onsite or nearby with a larger and Childhood Center as part of the more modern facility,and with family village redevelopment,appropriate phasing of would require relocation of the development,disruption to on- Friendly Kitchen weekly meal site social service programs can program that meets at that site. be minimized or avoided. The Friendly Kitchen program would either be relocated permanently as a part of the redevelopment or may be accommodated as part of the range of social services provided at the family village. Solid Waste Planned Action Alternatives Same as Planned Action Study would result in construction- Area related waste generation. Library When the library is relocated,Same as Planned Action Study library services may be Area temporarily unavailable in the study area,but services would be available at other branches. Operations Police Applying the Renton Police Applying the Renton Police Department staffing per Department standard to the population standard to the anticipated population increase anticipated population increase would account for 1.0 to1.8 of the would result in a need for an approximately 8.6 to 9.3 estimated 8.6 to 9.3 additional additional police officers to police officers to address increase address population growth study in service calls related to growth. area. Fire and Emergency Medical Applying the fire service's staffing Applying the fire service's staffing Services ratio to growth in the study area ratio to growth in the study area would result in the need for an to the population growth of in this additiona11.2 to1.3 firefighter full- subarea would result in the need time equivalents(FTEs) for less than 0.14 to 0.2 of the 1.2 compared to existing conditions to1.3 firefighter FTEs needed in to maintain the City's existing the overall Planned Action Study staffing ratio. Area to maintain the City's existing staffing ratio. Education Population growth would result in Population growth would result in an increase in approximately 526 approximately 60 to 107 to 567 students in the Renton additional students compared to School District compared to existing conditions.It is existing conditions.The district's anticipated that this additional planned opening of Honey Dew increment of students would be Elementary,as well as accommodated by the district's construction of additions to planned capital improvements, McKnight Middle School and including openin Honey Dew Plann2d ACtion OfdinanCe 52 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea* Hazen High School,would Elementary,expansion of accommodate this increase in McKnight Middle School,and student population. redeveloping the Hillcrest Early New students within the study Childhood Center which would area would include a higher than provide additional student average number of students capacity in addition to early speaking English as a second education programs that language,increasing demands on currently exist on the site. the district's English Language Learners Program. Health Care Increase in study area population Based VMC's existing ratio of would increase the need for hospital beds to district hospital beds in the Valley population,the anticipated Medical Center(VMC)service population increase would result area by approximately 4.1 to 4.4 in a small increase of beds,based on the current ratio of approximately 0.5 to 0.8 hospital hospital beds to district service beds of the total assumed for the area population.Additional entire study area. population growth may aiso result in increased demand at VMC's nearby primary care and urgent care clinics. Social Services Planned Action Alternatives The subarea's new affordable include major public investments, housing development for seniors which could expand upon or would include enriched senior enhance social services in the services on site,including elder study area.Among the key day-health for off-site patients in components outside of Potential a 12,500-square-foot space on the Sunset Terrace Redevelopment northeastern vacant RHA parcel. Subarea is development of a The increased population of family village in the North affordable housing and,in Subarea. particular,affordable senior housing would increase the demand for social services, including senior services accessible to the subarea. Additional community space at the family village,would be located outside but nearby the subarea. Solid Waste Solid waste generation is Solid waste generation from the expected to increase by around subarea would increase by about 129,689 to 139,000 pounds per 14,750 to 9,300 pounds per week week compared to existing compared to existing conditions. conditions.A portion of this waste A percentage of this waste would stream would be diverted to be diverted to recycling. recyclables. Library Services Anticipated growth would create Anticipated growth in the subarea a demand for an additional 1,940 would account for approximately to 2,079 square feet of library 221-397 square feet of library space compared to existing facilities to meet the growth in Planned ACtlon OfdinanCe 53 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea* conditions. demand. Indirect and Cumulative All alternatives increase growth Same as Planned Action Study above existing conditions and Area would add to a citywide increase in demand for public services; however,the alternatives are accommodating an increment of growth already anticipated in the Comprehensive Plan at a citywide level,and planned growth to the year 2035 has been addressed in the City's 2015 Comprehensive Plan update. The overall conclusions of the FEIS is expected to be similar for the Reevaluation Alternatives in 2014 and 2016,except that patterns of growth and demand may slight shift to have slightly greater need in the Potential Sunset Terrace Redevelopment Area and slightly less in the overall neighborhood. Unavoidable Adverse Impacts Demand for public services will continue to increase in conjunction with population growth.With advanced planning and implementation of mitigation measures,no significant unavoidable adverse impacts related to police,fire/emergency medical,education,health care,social services,solid waste,or library services are anticipated. Mitigation Measures Table 32. Public Services Mitigation Measures Planned Action Study Area Potential Sunset Terrace Redevelopment Subarea Police Police During construction,security measures shall be Mitigation measures described for the Planned implemented by developers to reduce potential Action Study Area also apply to this Subarea. crimina activity,including on-site security Fire and Emergency Medical Services surveillance,lighting,and fencing to prevent Mitigation measures described for the Planned public access. Such measures shall be detailed in Action Study Area also apply to this Subarea. a construction mitigation plan prepared by Education Planned Action Applicants and approved by the No mitigation measures are necessary orCity. proposed. Planned Action applicants shall design street Health Carelayouts,open space,and recreation areas to promote visibility for residents and police.Street No mitigation measures are necessary or and sidewalk lighting would discourage theft and Proposed. vandalism,and enhance security. Social Services Fire and Emergency Medical Services RHA's provision of community space that could Developers will construct all new buildings in be used for social services or community meeting compliance with the International Fire Code and space for community organizations would serve Renton Development Regulations(RMC Title 4), as mitigation.See the discussion under the including provision of emergency egress routes P anned Action Study Area. and installation of fire extinguishing and smoke RHA should maintain a community meeting space Planned Action Ordinance 54 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT 6 Planned Action Study Area Potential Sunset Terrace Redevelopment Subarea detection systems.All new buildings will comply within or near the subarea during construction with accessibility standard for people with phase of Sunset Terrace redevelopment that disabilities,per the requirements of the allows for on-site social service programs to Americans with Disabilities Act. continue to meet within the subarea. Ptanned Action applicants shall pay a Fire Impact Solid Waste Fee as determined by the Renton Municipal Code Mitigation measures described for the Planned at the time of payment,payable to the City as Action Study Area also apply to this Subarea. specified in the Renton Municipal Code.Public Library Education The King County Library System should continue During renovation of the Hillcrest Early Childhood to monitor growth within its geographic clusters, Center,the Renton School District shall provide and adjust plans for facility sizing and spacing temporary transportation or take other according to shifting trends in population growth. equivalent measures to ensure accessibility of the early education program to area children who attend the program. Since the school district typically plans for a shorter-term horizon than the 20 years envisioned for the Planned Action,the district will continue to monitor student generation rates into the future and adjust its facility planning accordingly.The district will continue to implement existing plans to expand permanent student capacity at area schools.In addition,the district may utilize portable classrooms or shift attendance boundaries to address student capacity issues that arise on a shorter term basis. The district will also continue monitoring growth in the number of English Language Learner students in the district,and plan additional capacity in that program to meet growing demands for that service,particularly in schools with high percentages of English Language Learners,such as Highlands Elementary. The school district imposes a school impact fee for new residential construction.This funding source can be used to help provide expanded school facilities needed to serve the growth anticipated under all alternatives(RMC 4-1-160). Health Care There are no mitigation measures needed or proposed for health care due to the negligible change in the number of beds. Social Services The City's planned improvements to the streetscape and transit facilities that make walking,bicycling,and taking transit more viable modes of transportation would improve accessibility of social services located outside the Planned Action Study Area to area residents. RHA,Renton School District,and the City should work together to relocate the Friendly Kitchen community feeding program when the Hillcrest Planned ACtiOn OfdinanCe 55 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Planned Action Study Area Potential Sunset Terrace Redevelopment Subarea Early Childhood Center campus,the current site of this program,is redeveloped as part of a family village.Relocation should occur at an accessible location nearby to maintain service to the existing community that relies upon the Friendly Kitchen services.If possible,Renton School District and RHA should incorporate space for the continuation of the Friendly Kitchen Program within the family village. RHA and the City should consider developing a community center facility as part of Sunset Terrace redevelopment or the family village development or at another location in the Planned Action Study Area.The center would provide an accessible on-site space for a comprehensive range of social services for residents in the Planned Action Study Area,focused on alleviating poverty,and addressing the needs of some of the more predominant demographic groups found within the Planned Action Study Area—seniors, individuals living with disabilities,those speaking English as a Second Language,and youth. Solid Waste The City shall require development applicants to consider recycling and reuse of building materials when redeveloping sites,and as part of their application explain what measures are included. The City may condition Planned Action applications to incorporate feasible recycling and reuse measures. Public Gibrary The King County Library System should continue to monitor growth within its geographic clusters, and adjust plans for facility sizing and spacing according to shifting trends in population growth. Nexus Renton Comprehensive Pian RMC Title IV Chapter 1 Administration and Enforcement RMC Title IV Chapter 5 Building and Fire Prevention Standards 17. Utilities Significant Impacts Table 33. Utilities Impacts Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea* Planned ACtiOn OfdindnCe 56 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea* Construction Where new construction occurs, Same as Planned Action Study it is anticipated that existing Area telecommunication lines would be removed,replaced,or abandoned in place. Redevelopment would require coordination with service providers regarding the location of proposed structures,utilities, and site grading. To accommodate the required demand and capacity for water and sewer services for new development and redevelopment in the study area,existing water and sanitary sewer lines would be abandoned in place or removed and replaced with new and larger lines.New and larger water and sewer mains would be installed in existing and/or future dedicated public rights-of-way or within dedicated utility easements to the City,and would connect with the existing distribution network.Existing utility lines would continue to service the site during construction,or temporary bypass service would be implemented until the distribution or collection system is complete and operational. Operations Telecommunications Increased capacity requirements Same as Planned Action Study with increased levels of Area population and commercial activity in each of the alternatives could require new fiber within the Planned Action Study Area and coordination with telecommunication providers as development occurs should be performed so that appropriate facilities can be planned. Water The increase in the average daily The increase in ADD for this Planned ACtion OrdindnCe 57 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Potential Sunset Terrace Type of Impact Planned Action Study Area Redevelopment Subarea* demand(ADD)is projected to be subarea is 0.05 to 0.09 mitlion 0.56 to 0.59 million gallons per gallons per day.The increase in day within the Planned Action the peak daily demand (PDD)for Study Area. this subarea is 0.09 to 0.16 The growth projected would million gallons per day. increase the storage The primary significant impact of requirements for the Highlands subarea development on the 435 and 565 pressure zones and water distribution system would further increase the existing be related increased fire-flow storage deficit in the Highlands requirements.These increased 435 pressure zone.In addition, fire flow requirements are the development that is projected substantial and cannot be met by for the Planned Action Study Area the existing distribution system would increase the fire-flow serving the subarea. Water requirements with more system pressure provided by the multifamily development and 435 pressure zone within the commercial development.The subarea is not adequate for capacity of the existing water multistory development and/or distribution system to meet these for development with fire higher fire flows is inadequate if sprinkler systems. New water system improvements are not mains extended from the higher- constructed. pressure 565 pressure zone system to service the subarea would need to be phased to accommodate growth. Wastewater The increase in wastewater load The increase in wastewater flow for the Planned Action Study Area in this subarea is 0.05 to 0.10 is 0.59 to 0.63 million gallons per million gallons per day.Similar to day. the Planned Action Study Area, This increase in wastewater load no impacts on the interceptors is not expected to affect the that provide conveyance from the wastewater interceptors that subarea are expected,but the provide canveyance of increased sewer load could wastewater from the Planned impact local sewers within the Action Study Area but it could subarea. increase surcharging that is currently experienced and observed within the Planned Action Study Area. Indirect and Cumulative Demands on utilities would Same as Planned Action Study increase as a result of cumulative Area development.No significant cumulative impacts are anticipated as long as the replacement of water and sewer infrastructure is properly planned,designed,and constructed,and funding strategies are identified and approved by City Council. Planned ACtiOn OfdinanCe 58 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B The overall conclusions of the FEIS is expected to be similar for the Reevaluation Alternatives in 2014 and 2016,except that patterns of growth and demand may slight shift to have slightly greater need in the Potential Sun set Terrace Redevelopment Area and slightly less in the overall neighborhood. Unavoidable Adverse Impacts All studied alternatives are anticipated to increase demand for water,wastewater,and telecommunication services.Increased growth in the Planned Action Study Area has the potential to exacerbate existing water and wastewater system deficiencies. However,with application of mitigation measures,no significant unavoidable adverse impacts are anticipated. Mitigation Measures Table 34. Utilities Mitigation Measures Planned Action Study Area Potential Sunset Terrace Redevelopment Subarea Water Water To mitigate the current and projected water The mitigation measures that are required in the storage deficit in the pressure zones that serve Potential Sunset Terrace Redevelopment Subarea the study area,the City completed the are similar to those noted for the Planned Action construction of the 4.2-million-gallon Hazen Study Area.The water storage deficit would be met Reservoir in the Highlands 565 pressure zone with an increase in storage at the existing Highlands in March 2009.The City also completed a water Reservoirs site,and fire-flow requirements would distribution storage feasibility study to develop require the new 12-inch-diameter pipe loop conceptual options and planning level cost throughout this subarea and realignment of the estimates for expanding the storage capacity at Highlands 435 and Highlands 565 pressure zones. two existing City-owned sites:the Highlands As noted previously,the City has recently installed a Reservoirs site and the Mt.Olivet Tank site new 12-inch-diameter main for development HDR,Inc.2009).Financial strategies for the adjacent to this subarea,and as development occurs planning,design,and construction of the in the subarea,the pipe network would need to be storage-capacity expansion have not been extended to serve the development.A more detailed determined at this time. discussion of needed system improvements is To mitigate the fire-flow requirements for the provided in Attachment 2. proposed level of development and redevelopment within the Planned Action Study The NEPA Reevaluation/SEPA Addendum(October Area,larger diameter(12-inch)piping is Z014)provides a description of water system required throughout the Planned Action Study requirements for fire flow that are similar to the Area to convey the higher fire-flow FEIS conclusions and that benefit from more requirements.The new water mains will be specific master planning review. looped for reliability and redundancy of service, as required by City policies and water design ,yastewater Collection standards.The larger mains will be installed The sewers within the Potential Sunset Terracewithinthededicatedright-of-way in a north-to- Redevelopment Subarea are also identified for south and east-to-west grid-style water system. replacement based on age and condition in theAdditionalmainswithinthedevelopmentsites City's Long Range Wastewater Management Plan.will also be required to provide water to gased on the increased wastewater load within thehydrantsandwatermeters,and should be potential Sunset Terrace Redevelopment Subarea,looped within the development site around the local sewers may need to be replaced withbuitdings.To provide the water pressure requirements for multistory buildings and to upsized pipe to manage the increased wastewater support the pressure requirements for fire load from the subarea.A more detailed discussion of sprinkler systems,the new water mains will be needed sewer system improvements is provided connected to the higher-pressure Highlands Attachment 2. The NEPA Reevaluation/SEPA Addendum(October Planned Action Ordinance 59 Attachment 6:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT 6 Planned Action Study Area Potential Sunset Terrace Redevelopment Subarea 565 pressure zone.The options to address fire 2014)provides a description of sewer main flow within the Planned Action Study Area are considerations that are similar to the FEIS further described below. conclusions and that benefit from more specific The Highlands 565 pressure zone typically has master planning review. enough pressure to meet the pressure needs for fire-flow requirements for the proposed development and redevelopment in the Planned Action Study Area,but is limited in providing the fire-flow rate due to the size of the existing water mains that are generally smaller than 12 inches in diameter.The Highlands 435 pressure zone operates at lower pressures and has smaller-diameter pipes in this area of the pressure zone and,therefore, cannot meet both the pressure reyuirements and the fire-flow capacity(flow)requirements. The options developed to remedy fire-flow and pressure inadequacies are shown in Draft EIS Section 4.17,Figure 4.17-1 and summarized below. A 12-inch-diameter pipeline loop shown in Draft EIS Section 4.17,Figure 4.17-1 was developed to extend the Highlands 565 pressure zone into the existing Highlands 435 pressure zone.This 12-inch-diameter loop was also extended north of NE 12th Street in the existing Highlands 565 pressure zone to improve the conveyance capacity throughout the Planned Action Study Area.This 12-inch- diameter loop improvement builds on the City's recent extension of the Highlands 565 pressure zone into the Highlands 435 pressure zone to support fire-flow requirements for the Harrington Square Development. In addition to the 12-inch-diameter pipe loop shown in Draft EIS Section 4.17,Figure 4.17-1, additional piping improvements for each development served from the 12-inch-diameter loop are expected to be reGuired to provide sufficient fire flow and pressure throughout each development.The sizing and layout of this additional piping will depend on the development layout,but will require that the development piping be looped around buildings and be sufficient in size to maintain the fire- flow requirements of the development. Planned Action Applicants shall implement improvements required for water service and fire flow consistent with City standards in RMC Title 4 Chapter 6 and RMC 4-5-070 International Fire Code and Fire Prevention Regulations.Planned Action applicants shall also demonstrate compliance with RMC 4-1- Planned Action Ordinance 60 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Planned Action Study Area Potential Sunset Terrace Redevelopment Subarea 180 Charges for Equitable Share of Public Works Facilities. Wastewater Collection The local wastewater collection system n the Planned Action Study Area is scheduled for replacement based on age and condition as noted in the City of Renton Long Range Wastewater Management Plan (City of Renton 2009b).The local sewers have reached the end of their useful life and have been identified as high priority replacements due to leaks and current surcharging.However,the increased wastewater load with the development in the Planned Action Study Area could require that the local sewers be replaced with larger diameter pipe to provide sufficient capacity to the wastewater interceptors that serve the Planned Action Study Area.The locations where lines would be improved are identified in Draft EIS Section 4.17. Pursuant to RMC 4-6-040.B,any facility improvements identified by the current adopted long-range wastewater management plan(comprehensive sewer system plan)that are not installed or in the process of being installed must be constructed by the property owner(s)or developer(s)desiring service. Planned Action applicants shall also demonstrate compliance with RMC 4-1-180 Charges for Equitable Share of Public Works Facilities. Nexus Renton Comprehensive Plan RMC Title IV Chapter 1 Administration and Enforcement RMC Title IV Chapter 6 Street and Utility Standards Advisory Notes The EIS identified potentially applicable federal,state,and local laws and rules that apply to Planned Actions and that can serve to mitigate adverse environmental impacts. It is assumed that all applicable federal,state,and local regulations would be applied.The primary set of applicable local regulations is the Renton Municipal Code. A list of specific requirements included in Chapter 3 of the Draft EIS. Pldnned ACtiOn OfdindnCe 61 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Attachment 1: Draft EIS, Cultural Resources Appendix J, Plan and Procedures for Dealing with the Unanticipated Discovery Plan and Procedures for Dealing with the Unanticipated Discovery of Human Skeletal Remains or Cultural Resources during Redevelopment of the Edmonds- Glenwood Lot, Harrington Lot, and Sunset Terrace Public Housing Complex in Renton, Washington Any human skeletal remains that are discovered during this project will be treated with dignity and respect. A. If any City of Renton employee or any of the contractors or subcontractors believes that he or she has made an unanticipated discovery of human skeletal remains or cultural resources,all work adjacent to the discovery shall cease.The area of work stoppage will be adequate to provide for the security,protection,and integrity of the human skeletal remains,in accordance with Washington State Law.The City of Renton project manager will be contacted. B. The City of Renton project manager or the City of Renton representative will be responsible for taking appropriate steps to protect the discovery.At a minimum,the immediate area will be secured to a distance of thirty(30)feet from the discovery.Vehicles,equipment,and unauthorized personnel will not be permitted to traverse the discovery site. C. If skeletal remains are discovered,the City of Renton will immediately call the King County Sheriffs office,the King County Coroner,and a cultural resource specialist or consultant qualified to identify human skeletal remains.The county coroner will determine if the remains are forensic or non-forensic(whether related to a criminal investigation).The remains should be protected in place until this has been determined. D. If the human skeletal remains are determined to be non-forensic,the King County Coroner will notify the Washington State Department of Archaeology and Historic Preservation.DAHP will take jurisdiction over the remains.The State Physical Anthropologist will make a determination of whether the remains are Native American or Non-Native American.DAHP will handle all consultation with the Muckleshoot Indian Tribe as to the treatment of the remains. E. If cultural resources are uncovered,such as stone tools or flakes,fire-cracked rocks from a hearth feature,butchered animal bones,or historic-era objects(e.g.,patent medicine bottles, milk tins,clay pipes,building foundations),the City of Renton will arrange for a qualified professional archaeologist to evaluate the find.Again,the cultural resources will be protected in place until the archaeologist has examined the find. F. If the cultural resources find is determined to be significant,the City of Renton cultural resource specialist/archaeologist or consulting archaeologist will immediately contact the Washington State Department of Archaeology and Historic Preservation and the Muckleshoot Indian Tribes Planned Action Ordinance 62 Attathment B:Mitigation Dotument ORDINANCE N0. 5813 ATTACHMENT B to seek consultation regarding the eligibility of any further discovery for inclusion in the National Register of Historic Places. CONTACT INFORMATION Rocale Timmons,Senior Planner City of Renton Department of Community and Economic Development Renton City Hall 1055 South Grady Way Renton,WA 98057 Phone: (425) 430-6578 Stephanie Kramer Assistant State Archaeologist Department of Archaeology and Historic Preservation PO Box 48343 1063 Capitol Way South Olympia,WA 98504-8343 Phone: (360) 586-3083 King County Sheriffs Office Headquarters 516 Third Avenue,Room W-150 Seattle,WA 98104-2312 Phone: (206) 296-4155 (non-emergency) Laura Murphy Muckleshoot Tribe Cultural Resources 39015 172nd Avenue SE Auburn,WA 98092 Phone: (253) 876-3272 Planned Action Ordinance 63 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Attachment 2: Figure 3.17-1 Potential Subarea Utility Improvements and Phasing Planned Action Ordinance 64 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B Water The mitigation measures that are required in the Potential Sunset Terrace Redevelopment Subarea are similar to those noted for the Planned Action Study Area.The water storage deficit would be met with an increase in storage at the existing Highlands Reservoirs site,and fire-flow requirements would require the new 12-inch-diameter pipe loop throughout this subarea and realignment of the Highlands 435 and Highlands 565 pressure zones.As noted previously,the City has recently installed a new 12-inch-diameter main for development adjacent to this subarea,and as development occurs in the subarea,the pipe network would need to be extended to serve the development.A more detailed discussion of needed system improvements is provided below. See NEPA Reevaluation/SEPA Addendum(October 2014) for more recent considerations on location of pipes and fire flow requirements. Overview Renton fire and building codes mandate minimum fire flows,durations,and pressure prior to occupancy of new structures. In the case of the Potential Sunset Terrace Redevelopment Subarea these mandated flows dictate substantial upgrades to the water distribution system. When the fire flow required for a new development exceeds 2,500 gallons per minute(gpm),the City also requires that the mains providing that fire flow be looped. Looped water mains provide more reliability and higher pressures under fire-flow conditions. City regulations also require installation of fire hydrants along all arterials such as NE Sunset Boulevard. Taken together these code requirements would lead to a series of new water mains connected to the 565 pressure zone and extended to the various redevelopment projects within the subarea. It is not possible to predict the precise timing and sequencing of these redevelopment projects. The following paragraphs illustrate one scenario of water main sequencing that could meet fire-flow requirements. Edmonds-Glenwood Phase 1 Phase 1 of the Edmonds-Glenwood redevelopment project consists of townhomes along Glenwood Avenue NE. Fire-flow requirements for this project are expected to be in the range of 2,500 gpm. The existing water system in Glenwood Avenue NE cannot provide that amount of fire flow. A new 12-inch-diameter water main would be required to be extended from Harrington Avenue NE and NE 12th Street in the 565 pressure zone,south along Harrington Avenue NE,and continuing along Glenwood Avenue NE past and through the project site,about 800 feet of new pipe(Segment A on Figure 3.17-1). New Library A new library is proposed in the northeast quadrant of NE Sunset Boulevard and Harrington Avenue NE. If the fire-flow requirements for the new library are about 2,500 gpm or less,then the existing 12-inch-diameter main in NE Sunset Boulevard could meet that requirement. Pldnned ACtiOn OfdinanC2 65 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B New Mixed-Use Building Adjacent to New Library A new mixed-use community service/retail/residential structure is proposed adjacent to the new library between NE Sunset Boulevard,NE 10th Street,and Sunset Lane NE. It is reasonable to expect that the combination of additional structure size and exposure(to the library)would mandate fire flows for this building in excess of 2,500 gpm. In that case,a looped system of mains from the 565 pressure zone would be required. This could be achieved by extending new mains from the existing 12-inch-diameter main in NE Sunset Boulevard northwesterly on both Harrington Avenue NE and NE 10th Street to Sunset Lane NE. The loop could then be connected by installing a new 12-inch- diameter main in Sunset Lane NE from Harrington Avenue NE to NE 10th Street.The existing water main in Sunset Lane NE could then be abandoned in place. This new loop would be about 700 feet in total length(Segment B on Figure 3.17-1). RHA's Piha Site (aka Suncrest Homes) Fire flows required for the Piha site development have not been established. If the flow requirement is 2,500 gpm or less,then it could be met by extending a new 12 inch main in NE 10 h Street past the site to Harrington Avenue NE. The extension could either be from NE Sunset Boulevard(if the project precedes the mixed use development adjacent to the library). Or it could be from Sunset Lane NE,if the project occurs after the mixed use development adjacent to the library. The length of pipe required from Sunset Boulevard would be about 500 feet;from Sunset Lane NE it would be about 350 feet. (Segment C on Figure 3.17-1) It is possible that required fire flows for the Piha site would exceed 2,500 gpm. In that situation a looped main system would be necessary. There are multiple scenarios to meet the looping requirements. Those fire flow looping scenarios depend largely on the timing and sequencing of the PISA site project;i.e.does it precede or follow other redevelopment projects contemplated for the project area. Under one scenario,if the Piha site development precedes construction of Phase II and III of the Sunset Terrace redevelopment looping could be achieved by extending another main(in addition to Segment C,discussed above) north on Harrington Avenue NE to Glenwood Avenue NE (Segment H on Figure 3.17-1). If Piha site development follows Phases II and III of Sunset Terrace,looping could be achieved by simply connecting the Piha main extension in NE 10th Street(Segment C)with Segment E at the intersection of Harrington Avenue NE and NE lOth Street. Under another scenario,the Piha site development could proceed before all other projects. In that case the cost of looping would not be shared with other projects as described in the preceding paragraphs and the Piha site project would need to install either a"long-term"or a"temporary" 12 inch diameter"stand alone"water main loop. The"long-term"alignment would be to extend a 12-inch main in Harrington Avenue NE connecting to the existing high-pressure water line in NE Sunset Blvd. This option would result in the installation of a new water main in the section of Harrington Avenue NE that is proposed to be vacated to help create the Sunset Terrace Redevelopment Neighborhood Park. The new 12-inch water main would be looped around the west and north side of the new Piha site building and extended southerly in Sunset Lane NE to NE lOth Street,then southeasterly in NE 10th Street to connect back to the existing 12-inch line in Sunset Boulevard NE. (Segment P1 on Figure 3.17-1) This new looped water main would be able to deliver about 5,000 gpm. Planned ACtiOn Ordinance 66 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B A temporary route(which is not the preferred option)to provide 5,000 gpm to the same site would be to extend two paralle112-inch water lines in NE lOth Street from the existing 12-inch line in Sunset Boulevard NE,along with a looped water main around the west and north side of the building,and a 12-inch line in Sunset Lane NE connecting back to the second new 12-inch main in NE 10 h Street. (Segment P2 on Figure 3.17-1) Sunset Terrace Redevelopment It is reasonable to assume that the fire flows required for the Sunset Terrace redevelopment would exceed 2,500 gpm,mandating installation of a looped system. In addition,Sunset Terrace abuts NE Sunset Boulevard,triggering the requirement to install hydrants every 400 feet along that arterial. It may be possible to phase the Sunset Terrace redevelopment in a manner that would allow early elements of the redevelopment to be constructed without looping the water mains(see Edmonds- Glenwood Phase 1,above). In any case,all mains serving the redevelopment would be extended from the 565 pressure zone. Initially,a new water main would be installed in Sunset Lane NE from Harrington Avenue NE to Glenwood Avenue NE(about 750 feet). This presumes that the new main in Harrington Avenue NE discussed in the Mixed-Use Building section,above,has been installed. The existing water main in Sunset Lane NE could be abandoned in place(Segment D on Figure 3.17-1). Looping the system could be achieved by extending the main from the intersection of Sunset Lane NE and Glenwood Avenue NE along the newly aligned NE 10th Street to Harrington Avenue NE about 250 feet) (Segment E on Figure 3.17-1).This presumes that the water main extension in NE lOth Street to serve RHA's Piha site has already be installed. There are two ways to install the required fire hydrants along NE Sunset Boulevard. One option would be to extend the 12-inch-diameter main in NE Sunset Boulevard from Harrington Avenue NE along the Sunset Terrace frontage(about 800 feet). This would be the most expensive option. Another option would be to extend fire hydrant leads southwesterly through the Sunset Terrace project from Sunset Lane NE to NE Sunset Boulevard at the appropriate intervals(Segments F on Figure 3.17-1).This would be the least expensive option for two reasons. First,the pipes would not be installed in a street avoiding significant restoration costs. Second,the pipes could be smaller because they would be single purpose and not part of the City's transmission/distribution system. Edmonds-Glenwood Phase 2 Fire-flow requirements for the Edmonds-Glenwood Phase 2 project are expected to be about 4,000 gpm,triggering the requirement to loop the water system. There are two options to meet this looping requirement:north or south. The north option would involve extending the 12-inch-diameter main from Phase 1 westerly through the site to Edmonds Avenue NE. From there,the main would be extended north in Edmonds Avenue NE to NE 12th Street,then east in NE 12th Street to Harrington Avenue NE,a distance of more than 1,500 feet(Segment G on Figure 3.17-1). The south option would begin in the same manner by extending the Phase 1 main through the project site. Looping would be achieved by installing two new mains. One would extend from Sunset Lane NE north in Glenwood Avenue NE to the Phase 1 pipe. The other would extend Planned Action Ordinance 67 attachment s:nnitigation oocument ORDINANCE N0. 5813 ATTACHMENT B northwesterly in easements adjacent to NE Sunset Boulevard and Edmonds Avenue NE from the northern-most fire hydrant lead installed for the Sunset Terrace project through the Phase 2 site. (A more expensive option would be to install this same section of pipe in the rights-of-way of NE Sunset Boulevard and Edmonds Avenue NE.) These loops would also comprise more than 1,500 feet of new pipe (Segment H on Figure 3.17-1). Water Main Costs The cost of installation for new water mains is driven by a number of factors. Water mains installed in roads are more expensive than water mains installed within project or open space areas,because of the cost savings of avoiding conflicting utilities and restoring the road surface. New water main costs are also affected by whether they are stand-alone or part of a suite of infrastructure improvements. If the project is only installing a new water main,then all of the excavation,bedding,installation,and other costs are borne by that project. If the project involves installation of the other underground utilities such as sewers or storm sewers,the costs common to the project can be spread across each utility facility being installed. The cost of water mains is also affected by the project sponsor. If the project is being constructed by a private developer,new water mains are less expensive. If the project is sponsored by a government agency,numerous statutes make new water main projects more expensive. The City's recent experience with stand-alone water main projects in a major arterial indicate costs per foot of about$200 to$250. Applying these costs to the water main improvement described above would indicate costs in the range of$1 to 1.2 mil(ion.The improvements would be implemented with City and developer funding. Wastewater Collection Overview The sewers within the Potential Sunset Terrace Redevelopment Subarea are also identified for replacement based on age and condition in the City's Long Range Wastewater Management Plan. Based on the increased wastewater load within the Potential Sunset Terrace Redevelopment Subarea,the local sewers may need to be replaced with upsized pipe to manage the increased wastewater load from the subarea.A more detailed discussion of needed sewer system improvements is provided below. See NEPA Reevaluation/SEPA Addendum(October 2014)for more recent considerations on location of sewer mains and the potential for reuse of existing lines or rerouting requirements. Detailed Discussion Mitigation issues related to wastewater fall into three broad categories: upsizing,rehabilitation,and relocation. Wastewater flows(forecast for the Planned Action Study Area,including the Potential Sunset Terrace Redevelopment Subarea) indicate that some existing sewer pipes must be replaced with larger pipes. One of those pipes is in Harrington Avenue NE. This sewer pipe would be replaced by Planned Action Ordinance 68 Attachment B:Mitigation Document ORDINANCE N0. 5813 ATTACHMENT B the Ciry as part of the overall Sunset Terrace redevelopment to accommodate forecast flows. Manholes along the Harrington alignment would be carefully designed and located to avoid interference with the planned park. The collection sewers in Sunset Lane NE are at or near the end of their design life. The condition of these sewers would be assessed to determine if they can be rehabilitated in place or if new pipes would need to be installed. The redevelopment concept proposes narrowing and shifting the alignment of Sunset Lane NE. If this action leaves the existing sewers too close to new structures,then the City would require that a new sewer main be installed within the new right-of-way of Sunset Lane NE. Planned ACtion Ordinance 69 Attachment B:Mitigation Dotument ORDINANCE N0. 5813 ATTACHMENT B r t2w st y f f r Private Rd t f_ oR- i utz A a sK, a z a 0 D a w r S. oa,a 5 NE 1Q[h St w NE 9th pt Z NE 9th pf Afy " m Ferndale Cir NE Flrelbw Phase A E BJlding P1 e F 0 100 200 300 400 t e saeet: P2 re et llio i MM E aingwatttPlpes Figure 3.17-1 Fireflow Phasing—Potential Sunset Terrace Redevelopment Subarea Sunset Area Community Planned Action Final NEPA/SEPA EIS Planned Action Ordinance Attachment B:Mitigation Document Sunset Terrace Master Site Plan I „ T, , f_ _--- 1 1.... ir- -.+.++ t. tt i' . y \ i j -: a I _ n. v/ ,' e' - s t i ,,_, j' f;; JI J 3 r' o I ! i _._._. D J jf f 4 D D ry 11 2 n a, sn ` m zo s s Gy W rv i . y 617 P p // f i ' i V ` floo a 1J a , 1 ' re KEY RESIDENTIAL 1 ' MIXED- USE I COMMUNITY i ____ 1-. 1 °' 1 .; SITE AREA t'• o• on aao ra 1:, RENTON SUNSET AREA MSP EXHIgIT 9 DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Notice of Revised Record of Decision Sunset Area Community EIS The City of Renton, acting under its authority as Responsible Entity (RE) for conducting environmental review for the US Department of Housing and Urban Development (HUD), hereby provides notice of its Revised Record of Decision (ROD) for the Sunset Area Community Planned Action Environmental Impact Statement (EIS). Locations: The Sunset Terrace property is generally located at the intersection of Sunset Boulevard and Harrington Avenue. An Environmental Impact Statement (EIS) planned action study area was defined and bounded approximately by NE 21st Street on the north, Monroe Avenue NE on the east, NE 7th Street on the south, and Edmonds Avenue NE. Within the EIS study area, a master plan redevelopment of Sunset Terrace was evaluated, as well as replacement housing sites, and private development in the neighborhood. Description: Conceptual plans propose redevelopment of Sunset Terrace and adjacent properties with mixed-income, mixed-use residential and commercial space and public amenities. The Sunset Terrace property and associated properties owned or purchased by RHA or by other public or private developers (e.g. Colpitts Development Company, LLC) would be developed with up to 722 total units on the Sunset Terrace property including nearby land swap/housing replacement sites. The redevelopment would include a 1-to-1 unit replacement for all 100 public housing units either on-site at Sunset Terrace or off-site at locations within the EIS study area. The project has relocated all existing residents pursuant to a relocation plan as part of the demolition and disposition permits granted by the US Department of Housing and Urban Development. Public amenities would be integrated with the development and could include a community gathering space; civic facilities; a new park/open space; retail shopping and commercial space; and green infrastructure. An EIS, published in 2011 under National Environmental Policy Act (NEPA) and the State Environmental Policy Act (SEPA), addresses the primary proposal of the Sunset Terrace area redevelopment and evaluates neighborhood redevelopment and supporting services and infrastructure improvements. Conceptual master plans were updated in 2014 and 2016 and reevaluations under NEPA and SEPA were conducted and revised Records of Decision noticed. In 2019, RHA has proposed a redistribution of Master Plan dwelling units within the Master Plan area. A property may be removed from the master plan but would still develop with allowed uses in the neighborhood. The proposed changes would redistribute dwelling units, but there would be no net increase in the total number of housing units in the Master Plan area or in the Sunset Area neighborhood. The City may amend its Planned Action Ordinance applicable to the Sunset Area pursuant to SEPA. A Reevaluation, consistent with applicable National Environmental Policy Act (NEPA) regulations, combined with a SEPA Addendum, was prepared to evaluate the changes in the conceptual master plan. The Reevaluation/Addendum concluded that there would no new or different impacts and that the conclusions of the EIS are still valid. The ROD documents the City’s consideration and conclusions with respect to environmental impacts and mitigation measures for various elements of the environment, as required by NEPA. The ROD does not constitute approval of development of the proposal. The ROD is also considered part of the Environmental Review Record. Copies of the revised ROD are available on the Digital Records Library at the City’s website: http://rentonwa.gov. DEPARTMENTOFCOMMUNITYANDECONOMICDEVELOPMENTResponsibleEntityCertifyingOfficerCityofRentonEnvironmentalReviewCommittee(ERC)Date:iZ/q’/tDateofDecision:December9,2019DateofPublication:December13,2019Signature:/!35IjSignature:,zhçSignature/fr1r%/7Signature:2. DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Adoption of Existing Environmental Document with Addendum Adoption for (check appropriate box) □ DNS X EIS □ other Description of current proposal Conceptual plans propose redevelopment of Sunset Terrace and adjacent properties with mixed-income, mixed-use residential and commercial space and public amenities. The Sunset Terrace property and associated properties owned or purchased by RHA or by other public or private developers would be developed with up to 722 total units on the Sunset Terrace property including nearby land swap/housing replacement sites. The redevelopment would include a 1-to-1 unit replacement for all 100 public housing units either on-site at Sunset Terrace or off-site at locations within the EIS study area. The project has relocated all existing residents pursuant to a relocation plan as part of the demolition and disposition permits granted by the US Department of Housing and Urban Development. Public amenities would be integrated with the development and could include a community gathering space; civic facilities; a new park/open space; retail shopping and commercial space; and green infrastructure. An EIS, published in 2011 under National Environmental Policy Act (NEPA) and the State Environmental Policy Act (SEPA), addresses the primary proposal of the Sunset Terrace area redevelopment and evaluates neighborhood redevelopment and supporting services and infrastructure improvements. Conceptual master plans were updated in 2014 and 2016 and reevaluations under NEPA and SEPA were conducted and revised Records of Decision noticed. In 2019, RHA has proposed a redistribution of Master Plan dwelling units within the Master Plan area. A property may be removed from the master plan but would still develop with allowed uses in the neighborhood. The proposed changes would redistribute dwelling units, but there would be no net increase in the total number of housing units in the Master Plan area or in the Sunset Area neighborhood. An Addendum to the Final EIS has been prepared to evaluate any changes to impacts associated with the 2019 revised master plan. The City may amend its Planned Action Ordinance applicable to the Sunset Area pursuant to SEPA. A Planned Action Ordinance does not require future SEPA threshold determinations or EISs for future projects that are consistent with EIS assumptions and mitigation measures. Proponent Renton Housing Authority Location of current proposal The Sunset Terrace property is generally located at the intersection of Sunset Boulevard and Harrington Avenue. The planned action neighborhood study area is generally bounded by NE 21st Street on the north, Monroe Avenue NE on the east, NE 7th Street on the south, and Edmonds Avenue NE. Title of document being adopted Sunset Area Community Planned Action Final NEPA/SEPA Environmental Impact Statement. April 2011. Prepared for City of Renton and the Renton Housing Authority, Renton, WA. Prepared by CH2MHill and ICF International, et al. An addendum to this document has been prepared. Agency that prepared document being adopted City of Renton was Responsible Entity and Lead Agency for the preparation of the EIS. DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Date adopted document was prepared April 2011 Description of document (or portion)being adopted The full ElS is being adopted,together with a Reevaluation/Addenda prepared in 2014 and 2016. If the document being adopted has been challenged (WAC 197-11-630),please describe: Not applicable The document is available to be read at: The Digital Records Library on the City’s website:http://rentonwa.gov/ The City has identified and adopted the document described above after independent review and has prepared an Addendum to the Final EIS to evaluate any changes in conclusions regarding the 2019 Reevaluation Alternative.The Addendum was combined with a Reevaluation pursuant to the National Environmental Policy Act (NEPA).The document meets our environmental review needs for the current proposal and will accompany the proposal to the decision maker. Name of agency adopting document City of Renton Contact person,if other than responsible official Matt Herrera,Senior Planner City of Renton -Current Planning 1055 South Grady Way Renton,WA 98057 Tel:(425)4306593 Fax:(425)430-7300 mherrera@rentonwa.gov Responsible Official City of Renton Environmental Review Committee (ERC) Date:/L///r% Signatu Signatu Signature: