Loading...
HomeMy WebLinkAboutMFP19004284.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP19004284 IVR Number: 19004284 Permit Informaon Permit Name:Comcast Cable Franchise Permit Address/Locaon :08/02/2019Application Date:1923059043Parcel Number:501 S GRADY WAY Permit Type:08/09/2019Issue Date:Franchise Permit Work Class:08/10/2020Expiration Date:Minor Utility Job Number:JB0000085438Franchise Type:Cable Description:REVISION: After Pre con the proposed drilling now changed to open trench across S Renton Village Pl. Bore approx 75 LF, place two 2" conduits and pull new wire. Proof and pull wire through existing conduit. Work starts and terminates on private property. Pothole all existing utilities. Restoration per City of Renton standards. APPROVED WITH COMMENTS OR REDLINES Contacts Name Address PhoneTypeBilling Michael Kaiwi Cannon Construction Inc B: (253) 922-2787 C: (206) 683-0705 Applicant Tom Donnelly Comcast Business Communications 1701 Jfk Blvd, 32nd Floor Philadelphia, PA 19103 B: (215) 286-7347 C: (215) 286-7557 Contact Michael Cannon Cannon Constructors Inc 406 Porter Way Milton, WA 98354 B: (253) 922-2787Contractor Business License Number: 41539Construction Contractor: CANNOCI055CS CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 H: (425) 741-5733Specialized Billing X General Condions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES RESTORATION PER CITY OF RENTON STANDARDSScott WarlickHolly Powers1/8/20201/8/2020 MFP19004284 Monday - Friday 8:00AM - 3:00PM Scott Warlick 1/3/2019 MFP19004284 MFP19004284 1 - COVER SHEET 2 -LEGEND 3 -GENERAL NOTES 4 -DETAIL 5 -OVERVIEW 6 -DESIGN 7 -NODE MAP 8-9 -SITE PHOTOS 10-11 -TCPS THIS IS PROPRIETARY INFORMATION AND NOT MEANT FOR GENERAL PUBLICATION. ALL RIGHTS RESERVED CANNON COMPANIES 12 CT FIBER: 364 FT + 20% STORAGE = 437 FT CONTACTS: PROJECT MAP: *ALL FOOTAGES AND MATERIALS ARE ESTIMATED N SCOPE OF WORK: SHEET INDEX: BILL OF MATERIALS*: NEW AERIAL = OVERLASH = NEW UNDERGROUND = EXISTING UNDERGROUND = RISER (0)= TOTAL FOOTAGE = 0 FT. 0 FT. 75 FT. 219 FT. 0 FT. 294 FT. PROJECT DESCRIPTION - ROW* NEW BUILDING PATH WAY = EXISTING BUILDING PATH WAY = NEW UNDERGROUND = EXISTING UNDERGROUND = TOTAL FOOTAGE = 50 FT. 0 FT. 20 FT. 0 FT. 70 FT. PROJECT DESCRIPTION -SITE* TOTAL PROJECT FOOTAGE =364 FT. -TIE IN TO EXISTING SPLICE CASE -PROOF AND PULL (1) 12CT FIBER THROUGH EXISTING 2" OCCUPIED UNDERGROUND CONDUIT -OPEN TRENCH & PLACE (2) 2" CONDUITS & PULL (1) 12 CT FIBER THROUGH -TRANSITION TO EXISTING 4" CONDUIT, PROOF AND PULL (1) 12CT FIBER THROUGH -TRANSITION TO INSTALLING NEW 1-1/4" INNERDUCT -INSTALL TERM PANEL IN EXISTING CUSTOMER SERVER RACK CANNON COMPANIES SAFETY | QUALITY | INTEGRITY | TEAMWORK Connecting The Future Since 1985 COMCAST Business/Job Contact POC:Sheri Takamura206-624-3315 EMAIL: sheri@uwajimaya.com Review _________________________ CANNON COMPANIES Nate Pinson - (425)-941-7820 - npinson@cannonconstructioninc.com COMCAST COMMUNICATION Kyle Kinney - (253)-235-7016 - Kyle_Kinney@cable.comcast.com 501 S GRADY WAY RENTON, WA 98057 UWAJIMAYA PC#500000 JB0000085438 METRO-E MFP19004284 N EOP FL P C S D G W TS T ST UT ROW DD DD DD DD EDGE OF PAVEMENT FOGLINE POWER COMMUNICATION SEWER DRAIN DRAINAGE DITCH GAS WATER TRAFFIC SIGNAL TELCOM STEAM UNKNOWN UTILITY RIGHT OF WAY TRAFFIC CONES PROPOSED NEW CONDUIT STRAW WATTLES P V LT CW R UTILITY POLE VAULT - SMALL PEDESTAL STREET LIGHT CROSSWALK LIGHT UTILITY RISER V VAULT - SMALL 444LA MANHOLE VAULT - 25TA CB CB CATCH BASIN CATCH BASIN WITH SOCK GLULAM UTILITY POLECENTER LINE LANE LINE FENCE HIGH VISIBILITY FENCE S SEWER MANHOLE D DRAIN MANHOLE W WATER MANHOLE V UTILITY VALVE SHRUBBERY BORE PIT VAULT - LARGE VAULT - 25TA C COMMUNICATION MANHOLE FIRE HYDRANT DISTANCE STATIONSTA 0+00 NOTE CALLOUT# X.X DISTANCE DIMENSION ASPHALT SURFACE CONCRETE SIDEWALK PANEL CONCRETE ROADWAY PANEL HF H-FRAME VAULT - LARGE CAB CABINET LEGEND LANE DIRECTION INDICATOR PROPOSED MARK-UP NOTATIONS RESTORATION TYPESEXISTING FEATURESLINE TYPES COMCAST SPLICE CASE OF DATE REVISION BY QC CANNON COMPANIES 0000085438UWAJIMAYA 501 S GRADY WAY RENTON, WA, 98057 LEGEND 2 9 07/01/2019 AH PM MFP19004284 COMCAST OF DATE REVISION BY QC CANNON COMPANIES 0000085438UWAJIMAYA 501 S GRADY WAY RENTON, WA, 98057 GENERAL NOTES 3 9 07/01/2019 AH PM MFP19004284 TRENCH - HARD SURFACE STANDARD DETAIL2TRENCH - SOFT SURFACE STANDARD DETAIL1 COMCAST OF DATE REVISION BY QC CANNON COMPANIES 0000085438UWAJIMAYA 501 S GRADY WAY RENTON, WA, 98057 DETAILS 4 9 07/01/2019 AH PM MFP19004284 555 501 S RENTON VILLAGE PL 12ct TIE IN TO SP.WAKV.0449(KV07S.3A.1B.1A.1A). USE CHANNELS 41 / 42 IN EXISTING MUX MX.WAKV.0029 40MX (20-59) IN SPLICE SP.WAKV.0449(KV07S.3A.1B.1A.1A). EXISTING 4" CONDUIT. PROOF AND PULL (1) 12CT FIBER CUSTOMER SERVER ROOM V VV PLACE NEW STRAP OUT CASE FROM SPLICE SP.WAKV.0449(KV07S.3A.1B.1A.1A). V 60' 155' 75' 20' 50' 4' V DIG AND INTERCEPT PHONE CONDUIT OPEN TRENCH & PLACE (2) 2" CONDUITS & PULL (1) 12 CT FIBER THROUGH EXISTING OCCUPIED 2" CONDUIT. PROOF AND PULL (1) 12CT FIBER N COMCAST OF DATE REVISION BY QC CANNON COMPANIES 0000085438UWAJIMAYA 501 S GRADY WAY RENTON, WA, 98057 OVERVIEW 5 9 07/01/2019 AH PM MFP19004284 555 501 S RENTON VILLAGE PL ROW ROW ROW ROW ROW ROW ROWROWROWROWROWROWROWEOPEOPEOPEOPEOPEOPEOPEOPEOP EOPEOPEOPEOPTIE IN TO SP.WAKV.0449(KV07S.3A.1B.1A.1A). USE CHANNELS 41 / 42 IN EXISTING MUX MX.WAKV.0029 40MX (20-59) IN SPLICE SP.WAKV.0449(KV07S.3A.1B.1A.1A). EXISTING 4" CONDUIT. PROOF AND PULL (1) 12CT FIBER CUSTOMER SERVER ROOM V VV PLACE NEW STRAP OUT CASE FROM SPLICE SP.WAKV.0449(KV07S.3A.1B.1A.1A). EOP EOPEOP EOP V 60' 155' 75' 20' 50' 4' V DIG AND INTERCEPT PHONE CONDUIT OPEN TRENCH & PLACE (2) 2" CONDUITS & PULL (1) 12 CT FIBER THROUGH EXISTING OCCUPIED 2" CONDUIT. PROOF AND PULL (1) 12CT FIBER N COMCAST OF DATE REVISION BY QC CANNON COMPANIES 0000085438UWAJIMAYA 501 S GRADY WAY RENTON, WA, 98057 DESIGN 6 9 07/01/2019 AH PM MFP19004284 MFP19004284 TIE IN AND PULL (1) 12CT1SPLICE CASE SP.WAKV.0449(KV07S.3A.1B.1A.1A) DRILL (2) 2" CONDUITS. PROOF AND PULL (1) 12CT FIBER 2 ACCESS TO 2ND VAULT PROOF AND PULL (1) 12CT FIBER3 4 TIE IN PULL (1) 12CT FIBER THROUGH EXISTING 2" UNDERGROUND CONDUIT V PROOF AND PULL (1) 12CT FIBER THROUGH EXISTING 2" CONDUIT PROOF AND PULL (1) 12CT FIBER THROUGH OCCUPIED 4" CONDUIT PROOF AND PULL (1) 12CT FIBER THROUGH OCCUPIED 4" CONDUIT PROOF AND PULL (1) 12CT FIBER DIG AND INTERCEPT PHONE CONDUIT OPEN TRENCH & PLACE (2) 2" CONDUITS & PULL (1) 12 CT FIBER THROUGH COMCAST OF DATE REVISION BY QC CANNON COMPANIES 0000085438UWAJIMAYA 501 S GRADY WAY RENTON, WA, 98057 PHOTOS (1)8 9 07/01/2019 AH PM MFP19004284 INSTALL NEW 1-1/4" INNERDUCT. PROOF AND PULL (1) 12CT FIBER5 6 SERVER ROOM ACCESS7UPSTAIRS SERVER ROOM INSTALL TERM PANEL IN CUSTOMER SERVER RACK8CUSTOMER SERVER ROOM INSTALL NEW 1-1/4" INNERDUCT. PROOF AND PULL (1) 12CT FIBER. FIRE PENETRATION FIRE PENETRATION INSTALL NEW 1-1/4" INNERDUCT. PROOF AND PULL (1) 12CT FIBER. UPSTAIRS SERVER ROOM INSTALL NEW 1-1/4" INNERDUCT. PROOF AND PULL (1) 12CT FIBER. ROOM WILL BE CREATED AT CUSTOMER SPECIFIED LOCATION FOR TERM PANEL IN CUSTOMER SERVER RACK. INSTALL NEW 1-1/4" INNERDUCT. PROOF AND PULL (1) 12CT FIBER COMCAST OF DATE REVISION BY QC CANNON COMPANIES 0000085438UWAJIMAYA 501 S GRADY WAY RENTON, WA, 98057 PHOTOS (2)9 9 07/01/2019 AH PM MFP19004284