HomeMy WebLinkAbout02 Bid Drawings_Cedar River Trestle Bridge RepairsRENTON
CITY OF
Last Saved by: USGN675479 on: Dec 20, 2019 9:36 AM File: Q:\FederalWay\2019\A19.0010\00\CADD\Dwgs\01_G01.dwgCopyright © WSP USA Inc. All Rights Reserved.WSP USA Inc.
Suite 300
Federal Way, WA 98003-2600
TEL: (206) 431-2300
FAX: (206) 431-2250
33301 9th Avenue South
18496SCOTT B R ANL
UNDSTATE O F W ASHIN
GTONSTRUCT
URAL E N G INEERPROF
E
SSIONAL E N G INEERCEDAR RIVER TRAIL TRESTLE
BRIDGE REPAIRS
CITY OF RENTON
RENTON, WASHINGTON
TACOMA
SEATTLE
EVERETT
BELLINGHAM
CANADA
OREGON
OLYMPIA
PACIFIC
OCEAN
RENTON
AREA MAP
SCALE: NTS
PROJECT
LOCATION
RENTON CITY COUNCIL:
RANDY CORMAN
RYAN MCIRVIN
VALERIE O'HALLORAN
RUTH PEREZ
KIM-KHANH VAN
ED PRINCE
CAPITAL PROJECT COORDINATOR:
BETSY SEVERTSEN, PARKS DIVISION
MAYOR:
ARMONDO PAVONE
VICINITY MAP
SCALE: NTS
COVER SHEET
CITY OF RENTON BID DOCUMENTSCEDAR RIVER TRAIL TRESTLE BRIDGE REPAIRS
GENERAL NOTES
X
X-X
X
X-X
X
X-X SCALE:
LEGEND:
WATER SURFACE
NORTH ARROW
ELEVATION OR SECTION CUT
PLAN, SECTION, DETAIL, OR ELEVATION CALLOUT
DRAWING WHERE SECTION, DETAIL,
OR ELEVATION IS CALLED FROM
PLAN, SECTION, DETAIL, OR ELEVATION
REFERENCE DRAWINGS
REFERENCE DRAWINGS ARE UNAVAILABLE
ELEVATIONS
SPECIAL INSPECTIONS
1.THE ELEMENTS REQUIRING SPECIAL INSPECTIONS PER IBC
CHAPTER 17 ARE:
a.STRUCTURAL STEEL
b.STRUCTURAL WELDING
c.PILING
d.HIGH STRENGTH BOLTS
e.CONCRETE
f.REINFORCING STEEL
g.ANCHOR BOLTS
SHORE PROTECTION
1.PROVIDE RIP RAP THAT MEETS THE REQUIREMENTS OF
WSDOT M41-10 SECTION 9-13.1, WITH THE EXCEPTION
THAT BROKEN CONCRETE RUBBLE SHALL NOT BE USED.
FOR GRADATION MEET THE REQUIREMENTS OF SECTION
9-13.1(4).
2.HAND PLACED RIPRAP SHALL BE INSTALLED PER WSDOT
M41-10 SETION 8-15.
RTP-#
X'-XX"±
REPLACE TIMBER POST TYPE
APPROXIMATE LENGTH OF TIMBER POST TO
BE REPLACED (FIELD VERIFY)
PILE POST
APPROXIMATE LENGTH OF TIMBER POST TO
BE REPLACED (FIELD VERIFY)
PP
X'-XX"±
ABBREVIATIONS CONT.
HORIZ HORIZONTAL
HS HIGH STRENGTH
HSS HOLLOW STRUCTURAL SECTION
IBC INTERNATIONAL BUILDING CODE
IN INCH
INT INTERIOR
L ANGLE (E.G. L4x4x1/4)
LB(S)POUND(S)
LF LINEAL FEET
LLV LONG LEG VERTICAL
MAX MAXIMUM
MB MACHINE BOLT
MIN MINIMUM
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OHWM ORDINARY HIGH WATER MARK
OPP OPPOSITE
PL PLATE
PP PILE POST
PSF POUNDS PER SQUARE FOOT
R RADIUS
REQ'D REQUIRED
REINF REINFORCEMENT
RTP REPLACE TIMBER POST
SCH SCHEDULE
SECT SECTION
SIM SIMILAR
SP,SPA SPACE(S)
SQ SQUARE
STD STANDARD
T&B TOP & BOTTOM
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
W/WITH
W/O WITH OUT
WCLIB WEST COAST LUMBER INSPECTION BUREAU
WT WEIGHT
WWPI WESTERN WOOD PRESERVERS INSTITUTE
XS EXTRA STRONG (E.G., PIPE4X-STRONG)
CODES AND STANDARDS
1.IBC 2015 AS AMENDED AND ADOPTED BY THE CITY OF
RENTON
2.SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS (AISC
360) 2010, AND CODE OF STANDARD PRACTICE FOR STEEL
BUILDINGS AND BRIDGES (AISC 303) 2010
3.STRUCTURAL WELDING CODE - STEEL (AWS D1.1) - 2015
4.NATIONAL DESIGN SPECIFICATION FOR WOOD
CONSTRUCTION, 2015, BY THE AMERICAN WOOD
COUNCIL (NDS)
5.BUILDING CODE REQUIREMENTS FOR STRUCTURAL
CONCRETE AND COMMENTARY, ACI 318-14, IN ADDITION
TO OTHER ACI DOCUMENTS AS REFERENCED
6.STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND
MUNICIPAL CONSTRUCTION (M41-10), 2018,
WASHINGTON STATE DEPARTMENT OF TRANSPORTAION
(WSDOT)
GENERAL
1.THESE NOTES CONTAIN GENERAL INFORMATION AND ARE
NOT NECESSARILY COMPLETE FOR CONSTRUCTION
PURPOSES. VERIFY INFORMATION SHOWN ON THE
DRAWINGS WITH OTHER DOCUMENTS AND BRING
CONFLICT(S) TO THE ATTENTION OF THE CITY BEFORE
BEGINNING THE AFFECTED WORK. THE CITY WILL RESOLVE
THESE CONFLICT(S).
2.SUBMIT SHOP DRAWINGS FOR TIMBER ELEMENTS,
REINFORCEMENT, AND MISCELLANEOUS STEEL TO THE
CITY PRIOR TO FABRICATION. DO NOT BEGIN FABRICATION
UNTIL APPROVED BY THE CITY.
3.PROVIDE TEMPORARY SUPPORT TO EXISTING
STRUCTURES AS REQUIRED TO MAINTAIN STABILITY,
AVOID UNDUE STRESS, AND PREVENT DAMAGE PRIOR TO
AND DURING REPAIR WORK. SUBMIT DETAILS FOR
TEMPORARY SUPPORT TO THE CITY FOR REVIEW AND
APPROVAL.
4.THE TIMBER TRESTLE AND STEEL BRIDGE WILL BE CLOSED
TO THE PUBLIC DURING CONSTRUCTION. SUBMIT A
TRAFFIC CONTROL PLAN TO THE CITY FOR REVIEW AND
APPROVAL PRIOR TO THE START OF CONSTRUCTION. DO
NOT STORE EQUIPMENT OR MATERIALS ON THE TRESTLE
OR BRIDGE.
5.VERITY DIMENSIONS AND DETAILS PRIOR TO
PROCUREMENT OF MATERIALS, FABRICATION, AND
CONSTRUCTION.
DEMOLITION AND CONSTRUCTION
1.CONTAIN DEMOLITION WITHIN THE LIMITS DESIGNATED.
DO NOT DAMAGE EXISTING STRUCTURES, UTILITIES, OR
FACILITES.
2.DAMAGE CAUSED BY THE CONTRACTOR'S OPERATIONS TO
EXISTING FEATURES, STRUCTURES, OR UTILITIES THAT ARE
TO REMAIN SHALL BE REPAIRED AT THE CONTRACTOR'S
EXPENSE.
3.PREVENT, AVOID, AND MINIMIZE THE POTENTIAL FOR
DEMOLITION, CONSTRUCTION, OR OTHER DEBRIS TO FALL
ONTO THE SLOPE OR INTO THE WATER BY UTILIZING
TARPS, FLOATS, OR OTHER MEANS.
4.MONITOR OVERWATER DEMOLITION AND
CONSTRUCTION ACTIVITIES AND IMMEDIATELY REMOVE
AND DISPOSE OF ANY DEBRIS THAT ENTERS THE WATER IN
ACCORDANCE WITH FEDERAL, STATE, AND LOCAL
REGULATIONS AND PERMIT REQUIREMENTS. MODIFY
CONTAINMENT METHODS IF MONITORING INDICATES
THAT THE METHODS IN USE ARE NOT EFFECTIVE.
5.PERFORM WORK IN ACCORDANCE WITH PERMIT
REQUIREMENTS.
STRUCTURAL TIMBER
1.GENERAL
a.PROVIDE PACIFIC COAST DOUGLAS FIR-LARCH,
GRADE DENSE NO. 1 ELEMENTS CONFORMING TO
THE LATEST SPECIFICATIONS OF THE WCLIB.
b.DRILL HOLES FOR BOLTS 1/16 INCH LARGER THAN
BOLT DIAMETERS. PRE-BORE LEAD HOLES FOR LAG
SCREWS TO 65 PERCENT OF THE SHANK DIAMETERS.
2.PRESSURE TREAT STRUCTURAL TIMBER ELEMENTS IN
ACCORDANCE WITH AWPA STANDARDS T1, U1 AND UC4B
WITH A MINIMUM RETENTION OF 0.60 POUNDS PER CUBIC
FOOT OF ACZA. INCORPORATE BMP'S AS SET FORTH BY THE
WWPI.
3.HANDLING AND STORAGE: AFTER TREATMENT,
PRESSURE-TREATED TIMBER SHALL BE CARED FOR IN
ACCORDANCE WITH THE APPLICABLE SECTIONS IN AWPA
SPECIFICATION M4.
4.TREAT FIELD CUT ENDS OF TIMBERS AND FIELD DRILLED
HOLES IN TIMBERS, IN ACCORDANCE WITH AWPA
STANDARD M4.
STRUCTURAL STEEL
1.STEEL PLATES AND BARS: ASTM A 572 (FY=50 KSI)
2.ANGLES AND CHANNELS: ASTM A 36 (FY=36 KSI)
3.FASTENERS (UNLESS OTHERWISE NOTED)
a.BOLTS AND ECONOMY BOLTS: ASTM A 307, GRADE A
a.HIGH-STRENGTH BOLTS: ASTM F3125, GRADE 325
b.NUTS: ASTM A 563, HEAVY HEX, GRADE SUITABLE
FOR THE TYPE OF BOLT
c.PROVIDE MALLEABLE IRON WASHERS UNDER NUT
AND BOLT HEADS BEARING ON TIMBER, EXCEPT
UNDER THE HEADS OF ECONOMY BOLTS. CONFORM
TO ASTM F 436 FOR WASHERS BEARING AGAINST
STRUCTURAL STEEL SURFACES AT HIGH-STRENGTH
BOLTS AND ASTM F 844, WIDE SERIES, MAXIMUM
THICKNESS FOR OTHER WASHERS.
4.HOT-DIP GALVANIZE STRUCTURAL STEEL AND FASTENERS.
GALVANIZE ITEMS AFTER FABRICATION AS FAR AS
PRACTICAL. RESTORE GALVANIZING DAMAGED BY
WELDING OR HANDLING WITH A FIELD-APPLIED
GALVANIZING COMPOUND IN ACCORDANCE WITH ASTM A
780, ANNEX A1, 12 MILS MINIMUM THICKNESS.
CAST-IN-PLACE CONCRETE
1.MINIMUM 28-DAY COMPRESSIVE STRENGTH: 5000 PSI
2.REINFORCING STEEL: ASTM A 706 GRADE 60, DEFORMED,
UNLESS NOTED OTHERWISE.
3.DETAIL REINFORCING STEEL IN ACCORDANCE WITH ACI
315. FOLLOW ACI 315 AND CRSI MSP FOR REINFORCEMENT
HOOKS AND BENDS UNLESS OTHERWISE SHOWN ON THE
DRAWINGS.
4.CHAMFER EXPOSED CORNERS 3/4 INCH.
5.CONCRETE FORMING: FOR REINFORCING CHAIRS,
SUPPORTS AND SPACERS, USE PRECST MORTAR BLOCKS,
ALL-PLASTIC OR EPOXY COATED WITH PRE-MOULDED
PLASTIC TIPS. PROVIDE SUPPORTS AT INTERVALS LESS
THAN 4 FEET ON CENTER.
6.CONCRETE CURING AND FINISHING:
a.TERMINOLOGY IS DEFINED IN ACI 301.
b.MOIST CURE CONCRETE SURFACES IN ACCORDANCE
WITH ACI 301 FOR A MINIMUM OF 7 DAYS UNLESS A
LONGER TIME IS REQUIRED IN THE SPECIFICATIONS.
c.TOP OF FOOTINGS SHALL HAVE A BROOM FINISH.
d.FORMED SURFACES SHALL HAVE A SMOOTH FORM
FINISH.
DEMOLITION CONT'D
6.PRIOR TO GENERAL DEMOLITION, SAWCUT WHERE
NOTED, OR OTHERWISE PROVIDE A SMOOTH CLEAN
BREAK BETWEEN ITEMS THAT ARE TO BE DEMOLISHED
AND ITEMS THAT ARE TO REMAIN.
7.DEMOLITION AND EXCESS CONSTRUCTION MATERIALS,
EXCEPT AS NOTED, SHALL BECOME THE PROPERTY OF THE
CONTRACTOR AND SHALL BE REMOVED AND DISPOSED
OF.
8.THE REMOVAL, HANDLING, AND DISPOSAL OF
DEMOLITION MATERIALS, INCLUDING CREOSOTE-TREATED
AND OTHER TIMBERS, SHALL BE IN ACCORDANCE WITH
ALL LOCAL, STATE, AND FEDERAL REQUIREMENTS. PROPER
DISPOSAL OF DEMOLITION AND CONSTRUCTION
MATERIALS SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR AND IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO FAMILIARIZE ITSELF WITH THE
MATERIALS TO BE DISPOSED OF; FEDERAL, STATE, AND
LOCAL REGULATIONS; AND PERMIT REQUIREMENTS.
9.WHEN TRIMMING EXISTING ELEMENTS IS REQUIRED, DO
NOT DAMAGE OR REDUCE THE LOAD-CARRYING CAPACITY
OF THE EXISTING ELEMENTS.
PILING
1.GENERAL
a.STEEL POSTS: ASTM A 252, GRADE 3 WITH A
MINIMUM YIELD STRENGTH OF 50 KSI
b.FOR OUTSIDE CIRCUMFERENCE OF THE POSTS, DO
NOT VARY BY MORE THAN 0.375 INCH FROM THE
CORRESPONDING DIAMETER SHOWN ON THE
DRAWINGS.
c.LIMIT THE VARIATION IN THE EDGE ALIGNMENT FOR
ABUTTING STEEL POST ENDS TO 0.1875 TIMES THE
WALL THICKNESS WITH A MAXIMUM ALLOWABLE
VARIATION OF 0.063 INCH.
d.CONFORM TO THE REQUIREMENTS OF API 5L,
SECTION 7.6, FOR STEEL POST STRAIGHTNESS.
e.LIMIT THE NUMBER OF SPLICES TO A MAXIMUM OF
ONE PER POST WITH A MINIMUM LENGTH OF 18
FEET PER PIECE. SPLICE POSTS WITH COMPLETE
JOINT PENETRATION BUTT WELDS.
2.CUT-OFF
a.CUT-OFF POSTS LEVEL WITH A TIGHT, UNIFORM FIT
BETWEEN THETOP BEARING PLATE AND PILE CAP
RESULTING IN FULL BEARING.
b.DO NOT ALLOW POST CUT-OFFS OR CUTTING
DEBRIS TO FALL INTO THE WATER OR INSIDE THE
POST.
3.TIMBER POSTS - CUT-OFF, TREATMENT, & WEDGES
a.CUT OFF TIMBER POSTS LEVEL AND TRUE.
b.DO NOT ALLOW POST CUT OFFS OR SAW TAILINGS
TO FALL INTO THE WATER.
c.AFTER BEING CUT OFF, TREAT POST TOPS WITH
MULTIPLE COATS OF COPPER NAPHTHENATE UNTIL
VISIBLE EVIDENCE OF FURTHER PENETRATION HAS
CEASED. CAP THE TREATED POST TOPS WITH A
LAYER OF 30-POUND ASPHALT-IMPREGNATED
ORGANIC FELT, MEASURING AT LEAST 6 INCHES
MORE THAN THE PILE TOP DIAMETER IN EACH
DIMENSION, FOLDED OVER THE SIDE OF THE PILE
EDGES AND FASTENED WITH LARGE-HEADED
ROOFING NAILS.
d.THE USE OF AN AZCA-TREATED HARDWOOD WEDGE
BETWEEN THE POST CUT OFF AND THE PILE CAP
SOFFIT WILL BE ALLOWED TO ENSURE A TIGHT FIT.
ONCE IN PLACE THE WEDGE SHALL BE TOE-NAILED
TO THE POST TOP TO ANCHOR IT IN POSITION. USE
16D NAILS FOR TOE-NAILING (MINIMUM TWO NAILS
PER WEDGE).
ABBREVIATIONS
ACI AMERICAN CONCRETE INSTITUTE
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
AITC AMERICAN INSTITUTE OF TIMBER CONSTRUCTION
API AMERICAN PETROLEUM INSTITUTE
APPROX APPROXIMATE
AWPA AMERICAN WOOD PROTECTION ASSOCIATION
ASTM AMERICAN SOCIETY FOR TESTING AND
MATERIALS
AWS AMERICAN WELDING SOCIETY
BMP BEST MANAGEMENT PRACTICE
BOT BOTTOM
CIP CAST-IN-PLACE
CENTER LINE
CLR CLEAR
CONC CONCRETE
CONN CONNECTION
CONT CONTINUOUS
CONT'D CONTINUED
CRSI CONCRETE REINFORCING STEEL INSTITUTE
CY CUBIC YARD
DBL DOUBLE
DEMO DEMOLITION, DEMOLISH
DIA, Ø DIAMETER
EA EACH
EL, ELEV ELEVATION
EQ EQUAL
EXIST EXISTING
EXT EXTERIOR
FB FLAT BAR
FT FEET
FRP FIBER REINFORCED POLYMER
GALV GALVANIZED
GR GRADE
RENTON
CITY OF
Last Saved by: USGN675479 on: Dec 6, 2019 9:35 AM File: Q:\FederalWay\2019\A19.0010\00\CADD\Dwgs\01_G02.dwgCopyright © WSP USA Inc. All Rights Reserved.WSP USA Inc.
Suite 300
Federal Way, WA 98003-2600
TEL: (206) 431-2300
FAX: (206) 431-2250
33301 9th Avenue South
18496SCOTT B R ANL
UNDSTATE O F W ASHIN
GTONSTRUCT
URAL E N G INEERPROF
E
SSIONAL E N G INEERGENERAL NOTES
CITY OF RENTON BID DOCUMENTSCEDAR RIVER TRAIL TRESTLE BRIDGE REPAIRS
SITE ACCESS PLAN - CEDAR RIVER TRAIL1
-SCALE: NTS
CEDAR RIVER TRAIL
PARKING LOT
PROPOSED SITE 1
G-4
PARKING LOT &
EAST TRAIL ACCESS
PEDESTRIAN BRIDGE
NO CONSTRUCTION ACCESS
RENTON
CITY OF
Last Saved by: USGN675479 on: Dec 20, 2019 9:52 AM File: Q:\FederalWay\2019\A19.0010\00\CADD\Dwgs\01_G03.dwgCopyright © WSP USA Inc. All Rights Reserved.WSP USA Inc.
Suite 300
Federal Way, WA 98003-2600
TEL: (206) 431-2300
FAX: (206) 431-2250
33301 9th Avenue South
18496SCOTT B R ANL
UNDSTATE O F W ASHIN
GTONSTRUCT
URAL E N G INEERPROF
E
SSIONAL E N G INEERSITE ACCESS PLAN
CITY OF RENTON BID DOCUMENTSCEDAR RIVER TRAIL TRESTLE BRIDGE REPAIRS
SITE PLAN - TIMBER TRESTLE AND BRIDGE REPAIR1
G-4 SCALE: 1"=15'-0"
1
S-1
1
S-2
2
S-4
1
S-4
1
S-3
3
S-10
2
S-10
2
S-10
RENTON
CITY OF
Last Saved by: USGN675479 on: Dec 6, 2019 9:47 AM File: Q:\FederalWay\2019\A19.0010\00\CADD\Dwgs\01_G04.dwgCopyright © WSP USA Inc. All Rights Reserved.WSP USA Inc.
Suite 300
Federal Way, WA 98003-2600
TEL: (206) 431-2300
FAX: (206) 431-2250
33301 9th Avenue South
18496SCOTT B R ANL
UNDSTATE O F W ASHIN
GTONSTRUCT
URAL E N G INEERPROF
E
SSIONAL E N G INEERSITE PLAN
CITY OF RENTON BID DOCUMENTSCEDAR RIVER TRAIL TRESTLE BRIDGE REPAIRS
PLAN - SUGGESTED PEDESTRIAN TRAFFIC CONTROL
SCALE: 1"=100'-0"
LEGEND:
NOTES:
SIDEWALK
CLOSED
SIDEWALK
CLOSED
W11-15
W11-15
W11-15
W11-15
W11-15
RENTON
CITY OF
Last Saved by: USGN675479 on: Dec 20, 2019 7:30 AM File: Q:\FederalWay\2019\A19.0010\00\CADD\Dwgs\01_G05.dwgCopyright © WSP USA Inc. All Rights Reserved.WSP USA Inc.
Suite 300
Federal Way, WA 98003-2600
TEL: (206) 431-2300
FAX: (206) 431-2250
33301 9th Avenue South
18496SCOTT B R ANL
UNDSTATE O F W ASHIN
GTONSTRUCT
URAL E N G INEERPROF
E
SSIONAL E N G INEERPEDESTRIAN CONTROL PLAN
CITY OF RENTON BID DOCUMENTSCEDAR RIVER TRAIL TRESTLE BRIDGE REPAIRS
9 8 7 6 5 4 3 2 1
13'-8"±
TO BENT 10
8 SPACES @ 13'-8"± = 109'-4"±
EXIST STEEL
BRIDGE ABOVE
EXIST BRIDGE
BEARING PAD, TYP
EXIST TRESTLE ABOVE4'-0"16'-6"±EXIST 10x18 TIMBER
FOUNDATION, TYP
EXIST CONC
FOUNDATIONFOUNDATION PLAN - TIMBER TRESTLE1
G-4 SCALE: 3/16" = 1'-0"
1
S-4
C BRIDGE BEARINGL
2'-8"±
3/16" = 1'-0"
feet
8440
scale
RTP-2
6'-9"±RTP-2
6'-0"±
RTP-2
6'-0"±
RTP-2
6'-0"±
RTP-2
6'-9"±
RTP-1
6'-0"±
RTP-1
6'-0"±
RTP-2
6'-9"±RTP-2
6'-0"±
RTP-1
8'-0"±
RTP-1
8'-3"±
RTP-2
9'-4"±
RTP-2
6'-0"±
EXIST CONC ABUTMENT
EXIST CONC FTG
EXIST WF BEAM
17 16 15 14 13 12 11 1018
8 SPACES @ 13'-8"± = 109'-4"±13'-8"±
TO BENT 9
EXIST DBL 6x12 TIMBER SILL, TYP
RTP-1
1'-4"±
RTP-2
7'-6"±
RTP-2
6'-2"±
RENTON
CITY OF
Last Saved by: USGN675479 on: Dec 6, 2019 9:56 AM File: Q:\FederalWay\2019\A19.0010\00\CADD\Dwgs\02_S01.dwgCopyright © WSP USA Inc. All Rights Reserved.WSP USA Inc.
Suite 300
Federal Way, WA 98003-2600
TEL: (206) 431-2300
FAX: (206) 431-2250
33301 9th Avenue South
18496SCOTT B R ANL
UNDSTATE O F W ASHIN
GTONSTRUCT
URAL E N G INEERPROF
E
SSIONAL E N G INEERMATCHLINE SEE BELOWMATCHLINE SEE ABOVENOTES:
1.FIELD VERIFY ALL DIMENSIONS PRIOR TO
FABRICATION AND PROCUREMENT OF
MATERIALS.
LEGEND:
EXIST 12x12 TIMBER POST
REPLACE TIMBER
FOUNDATION
REPLACE TIMBER POST TYPE 1,
SEE
REPLACE TIMBER POST TYPE 2,
SEE
RTP-1
X'-XX"±
4
S-5
2
S-5
RTP-2
X'-XX"±
3
S-5
FOUNDATION PLAN - TIMBER TRESTLE
CITY OF RENTON BID DOCUMENTSCEDAR RIVER TRAIL TRESTLE BRIDGE REPAIRS
FRAMING PLAN - TIMBER TRESTLE1
G-4 SCALE: 3/16"=1'-0"
3
S-6
1
S-6
1
S-4
RENTON
CITY OF
Last Saved by: USGN675479 on: Dec 6, 2019 9:57 AM File: Q:\FederalWay\2019\A19.0010\00\CADD\Dwgs\02_S02.dwgCopyright © WSP USA Inc. All Rights Reserved.WSP USA Inc.
Suite 300
Federal Way, WA 98003-2600
TEL: (206) 431-2300
FAX: (206) 431-2250
33301 9th Avenue South
18496SCOTT B R ANL
UNDSTATE O F W ASHIN
GTONSTRUCT
URAL E N G INEERPROF
E
SSIONAL E N G INEERFRAMING PLAN - TIMBER TRESTLE
CITY OF RENTON BID DOCUMENTSCEDAR RIVER TRAIL TRESTLE BRIDGE REPAIRS
R
I
V
E
R
F
LOW
EXIST STEEL APPROACH BRIDGEEXIST STEEL BRIDGE
130'-0"±
EXIST TIMBER TRESTLE
EXIST EXPANSION BEARING, TYP
EXTERIOR PORTAL FRAME, TYP
EXIST TOP TRUSS DIAGONAL FRAME, TYP
EXIST PEDESTRIAN GUARDRAIL, TYP
EXIST CONCRETE DECK
(EXPANSION JOINT NOT SHOWN)
EXIST PILE SUPPORTED BRIDGE PIER
EXIST CONCRETE BRIDGE PIER
EXIST INTERIOR PORTAL FRAME
EXIST CONCRETE ABUTMENT
EXIST TOP CHORD
RIVETED BUILT UP STEEL MEMBER
19 1/2" x 1'-8"
EXIST DIAGONAL, TYP
RIVETED BUILT UP STEEL MEMBER
6 3/8" x 1'-0 1/2"
EXIST STEEL GUSSET PLATE, TYP
EXIST VERTICAL POST
RIVETED BUILT UP STEEL MEMBER
12" x 1'-1", TYP
EXIST PEDESTRIAN GUARDRAIL, TYP
EXIST PILE SUPPORTED BRIDGE PIEREXIST CONCRETE BRIDGE PIER
EXIST CONCRETE DECK, TYP
EXIST STEEL GIRDER
PLAN - STEEL BRIDGE OVER CEDAR RIVER1
G-4 SCALE: 1/8"=1'-0"
ELEVATION - STEEL BRIDGE OVER CEDAR RIVER2
-SCALE: 1/8"=1'-0"
1
S-8
EXIST INCLINED END POST
RIVETED BUILT UP STEEL MEMBER
19 1/2" x 1'-8", TYP28'-2"±1
S-9
1
S-9
2
-12'-0" ±1/8" = 1'-0"
feet
16880
scale
BRIDGE JOINT SEAL,
SEE 1
S-10
PORTAL FRAM W/ STRUTS, EA END
STEEL BRIDGE REPAIR NOTES:
1.EXISTING BUILT UP MEMBER DIMENSIONS SHOWN ARE APPROXIMATE.
2.REMOVE, COLLECT AND PROPERLY DISPOSE OF ALL LOOSE DEBRIS COLLECTED IN/ON STEEL
BRIDGE SUPERSTRUCTURE, INCLUDING DEBRIS COLLECTED BETWEEN STEEL ANGLES.
3.ALL BOLTS USED IN THE REPAIRS OF THE STEEL BRIDGE SHALL BE ASTM F 3125, GRADE A325.
4.SUGGESTED INSTALLATION SEQUENCE FOR PORTAL FRAME REPAIRS:
a.CLEAR DEBRIS FROM PORTAL FRAME BOTTOM CHORD AND FIELD VERIFY ALL
DIMENSIONS AND EXISTING CONDITIONS.
b.TRIM EXISTING STRUTS ABOVE THE EXISTING RIVETS AS REQUIRED TO ALLOW PROPER
FIT-UP OF THE ANGLES.
c.INSTALL STEEL ANGLES AS SHOWN ON THE DETAILS AND BOLT INTO PLACE BY FASTENING
THE BOLTS NEAREST THE POSTS AND THEN EACH SUBSEQUENT BOLT TOWARDS THE
CENTER OF THE OF THE BRIDGE, ALTERNATING SIDES.
d.INSTALL AND WELD CENTER GUSSET SPLICE TO THE EXISTING GUSSET PLATE PRIOR TO
WELDING STEEL BARS TO THE TO THE ANGLES.
RENTON
CITY OF
Last Saved by: USGN675479 on: Dec 6, 2019 11:51 AM File: Q:\FederalWay\2019\A19.0010\00\CADD\Dwgs\02_S03.dwgCopyright © WSP USA Inc. All Rights Reserved.WSP USA Inc.
Suite 300
Federal Way, WA 98003-2600
TEL: (206) 431-2300
FAX: (206) 431-2250
33301 9th Avenue South
18496SCOTT B R ANL
UNDSTATE O F W ASHIN
GTONSTRUCT
URAL E N G INEERPROF
E
SSIONAL E N G INEERSTEEL BRIDGE PLAN AND ELEVATION
CITY OF RENTON BID DOCUMENTSCEDAR RIVER TRAIL TRESTLE BRIDGE REPAIRS
8'-0"±
6'-0"
3'-4"±
LEGEND:
PILE POST, SEE 4
S-6
EXIST BRIDGE BEARING ABOVE, TYP
REPLACE TIMBER
EXIST TIMBER PILE
CAP BELOW
EXIST 10x18 (FLAT)
TIMBER, TYP
1
S-7
EXIST 12x12 TIMBER, TYP
BRIDGE BEARING PLAN - WEST BRIDGE PIER2
G-4 SCALE: 1/4" = 1'-0"
IMAGE - WEST BRIDGE PIER FRAMING4
-SCALE: NTS
1/4" = 1'-0"
feet
8440
scale
NOTE: TIMBER CROSS BRACING AND TIMBER DEBRIS BARRIER FACING NOT SHOWN
TIMBER CROSS BRACING
TIMBER PILE TO BE POSTED
IMAGE - WEST BRIDGE PIER TIMBER FACING5
-SCALE: NTS
REMOVE & REPLACE EXISTING TIMBER FACING, ADD
ADDITIONAL FACING TO SECURE SHORE PROTECTION
IN PLACE. ASSUME 10 MEMBERS TO BE INSTALLED,
SEE
HAND PLACED RIP-RAP4'-0"± MIN, SEE DRAWING S-7HAND PLACED RIP-RAP
BETWEEN PILES & TIMBER
FACING IN WEST BRIDGE PIER
3
S-7
4
S-7
NOTE:
1.FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION AND PROCUREMENT OF MATERIALS.
2.REPLACE FLASHING AT NW AND SW BEARING PADS. FLASHING TO BE 16 GAUGE (GALV),
BEND AND FASTEN TO MATCH EXISTING, UNLESS OTHERWISE APPROVED BY THE
ENGINEER. APPROXIMATELY 80 SQUARE FEET PER BEARING.
3.REPLACE AND ADD ADDITIONAL TIMBER DEBRIS BARRIER FACING WITH 4X12 TREATED
TIMBER, SEE & FOR CONNECTION DETAILS.6'-0"±TYP7'-0"±TYPPP
X'-XX"±
2
S-7
CL CL CL
LC PILELC PILE26'-6"±2'-11"±TYP3'-6"±3'-6"±
PILE PLAN - WEST BRIDGE PIER1
G-4 SCALE: 1/4" = 1'-0"
EXIST TIMBER PILE, TYP
EXIST TIMBER PILE CAP ABOVE, TYP
IMAGE - WEST BRIDGE PIER3
-SCALE: NTS
NOTE: TIMBER CROSS BRACING AND TIMBER DEBRIS BARRIER FACING NOT SHOWN
BRIDGE BEARING
TIMBER PILE TO BE POSTED
TIMBER DEBRIS
BARRIER FACING
REMOVE & REPLACE EXIST
TIMBER FACING TO THE
APPROXIMATE EXTENTS
SHOWN, SEE
TIMBER FACING TO BE INSTALLED
3
-
4
-
1
S-7
PP
14'-6"±
PP
12'-6"±
1
S-7
TIMBER PILE TO BE POSTED
5
-
RENTON
CITY OF
Last Saved by: USGN675479 on: Dec 6, 2019 10:15 AM File: Q:\FederalWay\2019\A19.0010\00\CADD\Dwgs\02_S04.dwgCopyright © WSP USA Inc. All Rights Reserved.WSP USA Inc.
Suite 300
Federal Way, WA 98003-2600
TEL: (206) 431-2300
FAX: (206) 431-2250
33301 9th Avenue South
18496SCOTT B R ANL
UNDSTATE O F W ASHIN
GTONSTRUCT
URAL E N G INEERPROF
E
SSIONAL E N G INEERFOUNDATION AND FRAMING PLAN - TIMBER BRIDGE PIER
CITY OF RENTON BID DOCUMENTSCEDAR RIVER TRAIL TRESTLE BRIDGE REPAIRS
DETAIL - EMBED PLATE6
-SCALE: 2" = 1'-0"
SECTION - CONCRETE STRIP FOOTING5
-SCALE: 1" = 1'-0"
5
-
SECTION - REPLACE TIMBER POST TYPE 12
S-1 SCALE: 1" = 1'-0"
3
S-6
6
-
SECTION - REPLACE TIMBER POST TYPE 23
S-1 SCALE: 1" = 1'-0"
2
-
SECTION - TYPICAL TIMBER TRESTLE1
S-1
S-2
SCALE: 1/2" = 1'-0"
SECTION - TIMBER FOUNDATION REPLACEMENT4
S-1 SCALE: 1/2" = 1'-0"
2
-
5
-
RENTON
CITY OF
Last Saved by: USGN675479 on: Dec 6, 2019 10:37 AM File: Q:\FederalWay\2019\A19.0010\00\CADD\Dwgs\02_S05.dwgCopyright © WSP USA Inc. All Rights Reserved.WSP USA Inc.
Suite 300
Federal Way, WA 98003-2600
TEL: (206) 431-2300
FAX: (206) 431-2250
33301 9th Avenue South
18496SCOTT B R ANL
UNDSTATE O F W ASHIN
GTONSTRUCT
URAL E N G INEERPROF
E
SSIONAL E N G INEERDETAILS - SHEET 1 OF 6
CITY OF RENTON BID DOCUMENTSCEDAR RIVER TRAIL TRESTLE BRIDGE REPAIRS
DETAIL - TYPICAL PILE POST4
S-4 SCALE: 3/4" = 1'-0"
5
-
DETAIL - STRINGER REPLACEMENT1
-SCALE: 1" = 1'-0"
SECTION - STRINGER REPLACEMENT2
-SCALE: 1" = 1'-0"
2
-
6
-
DETAIL - TOP BEARING PLATE5
-SCALE: 1" = 1'-0"℄DETAIL - PILE TO PILE CAP CONNECTION3
S-5 SCALE: 2" = 1'-0"
DETAIL - STEEL ANGLE6
-SCALE: 2" = 1'-0"
RENTON
CITY OF
Last Saved by: USGN675479 on: Dec 6, 2019 11:03 AM File: Q:\FederalWay\2019\A19.0010\00\CADD\Dwgs\02_S06.dwgCopyright © WSP USA Inc. All Rights Reserved.WSP USA Inc.
Suite 300
Federal Way, WA 98003-2600
TEL: (206) 431-2300
FAX: (206) 431-2250
33301 9th Avenue South
18496SCOTT B R ANL
UNDSTATE O F W ASHIN
GTONSTRUCT
URAL E N G INEERPROF
E
SSIONAL E N G INEERDETAILS - SHEET 2 OF 6
CITY OF RENTON BID DOCUMENTSCEDAR RIVER TRAIL TRESTLE BRIDGE REPAIRS
ELEVATION - WEST BRIDGE PIER1
S-4 SCALE: 1/4"=1'-0"
SECTION - WEST BRIDGE PIER1
S-4 SCALE: 1/4"=1'-0"LIGHT LOOSE RIP-RAP± MIN, SEE NOTE 42
-
3
-
4
-
DETAIL - TIMBER FACING AT PILE POST4
-SCALE: 2" = 1'-0"
DETAIL - TIMBER FACING AT EXIST PILE3
-SCALE: 2" = 1'-0"
RENTON
CITY OF
Last Saved by: Garth.nelson on: Apr 22, 2019 12:21 PM File: Q:\FederalWay\2019\A19.0010\00\CADD\Dwgs\02_S07.dwgCopyright © WSP USA Inc. All Rights Reserved.WSP USA Inc.
Suite 300
Federal Way, WA 98003-2600
TEL: (206) 431-2300
FAX: (206) 431-2250
33301 9th Avenue South
18496SCOTT B R ANL
UNDSTATE O F W ASHIN
GTONSTRUCT
URAL E N G INEERPROF
E
SSIONAL E N G INEERDETAILS - SHEET 3 OF 6
CITY OF RENTON BID DOCUMENTSCEDAR RIVER TRAIL TRESTLE BRIDGE REPAIRS
5
-
SECTION - ANGLES AT INCLINED END POST2
-SCALE: 3"=1'-0"
SECTION - ANGLES AT STRUTS3
-SCALE: 3"=1'-0"
SECTION - ANGLES AT CENTER GUSSET PL4
-SCALE: 3"=1'-0"
DETAIL - CENTER GUSSET PL SPLICE5
-SCALE: 3"=1'-0"
3
-2
-
4
-
ELEVATION - END PORTAL FRAME LOOKING EAST1
S-3 SCALE: 3/4"=1'-0"
5
-
RENTON
CITY OF
Last Saved by: USGN675479 on: Dec 6, 2019 2:05 PM File: Q:\FederalWay\2019\A19.0010\00\CADD\Dwgs\02_S08.dwgCopyright © WSP USA Inc. All Rights Reserved.WSP USA Inc.
Suite 300
Federal Way, WA 98003-2600
TEL: (206) 431-2300
FAX: (206) 431-2250
33301 9th Avenue South
18496SCOTT B R ANL
UNDSTATE O F W ASHIN
GTONSTRUCT
URAL E N G INEERPROF
E
SSIONAL E N G INEERDETAILS - SHEET 4 OF 6
CITY OF RENTON BID DOCUMENTSCEDAR RIVER TRAIL TRESTLE BRIDGE REPAIRS
5
-
SECTION - ANGLES AT INCLINED END POST2
-SCALE: 3"=1'-0"
SECTION - ANGLES AT STRUTS3
-SCALE: 3"=1'-0"
SECTION - ANGLES AT CENTER GUSSET PL4
-SCALE: 3"=1'-0"
DETAIL - CENTER GUSSET PL SPLICE5
-SCALE: 3"=1'-0"
ELEVATION - INTERIOR PORTAL FRAME LOOKING WEST1
S-3 SCALE: 3/4"=1'-0"
3
-2
-
4
-5
-
RENTON
CITY OF
Last Saved by: USGN675479 on: Dec 6, 2019 2:04 PM File: Q:\FederalWay\2019\A19.0010\00\CADD\Dwgs\02_S09.dwgCopyright © WSP USA Inc. All Rights Reserved.WSP USA Inc.
Suite 300
Federal Way, WA 98003-2600
TEL: (206) 431-2300
FAX: (206) 431-2250
33301 9th Avenue South
18496SCOTT B R ANL
UNDSTATE O F W ASHIN
GTONSTRUCT
URAL E N G INEERPROF
E
SSIONAL E N G INEERDETAILS - SHEET 5 OF 6
CITY OF RENTON BID DOCUMENTSCEDAR RIVER TRAIL TRESTLE BRIDGE REPAIRS
DETAIL - BRIDGE JOINT SEAL1
S-3 SCALE: 2"=1'-0"
DETAIL - COMPRESSION SEAL REPLACEMENT2
G-4 SCALE: 2"=1'-0"
DETAIL - EXPANSION JOINT SEAL REPLACEMENT3
G-4 SCALE: 2"=1'-0"
RENTON
CITY OF
Last Saved by: USGN675479 on: Dec 6, 2019 11:32 AM File: Q:\FederalWay\2019\A19.0010\00\CADD\Dwgs\02_S10.dwgCopyright © WSP USA Inc. All Rights Reserved.WSP USA Inc.
Suite 300
Federal Way, WA 98003-2600
TEL: (206) 431-2300
FAX: (206) 431-2250
33301 9th Avenue South
18496SCOTT B R ANL
UNDSTATE O F W ASHIN
GTONSTRUCT
URAL E N G INEERPROF
E
SSIONAL E N G INEERDETAILS - SHEET 6 OF 6