HomeMy WebLinkAboutMFP20000179.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP20000179
IVR Number: 20000179
Permit Informaon
Permit Name:Comcast Cable Franchise Permit
Address/Locaon :01/13/2020Application Date:7231500720Parcel Number:304 MAIN AVE S
Permit Type:01/28/2020Issue Date:Franchise
Permit Work Class:01/27/2021Expiration Date:Minor Utility
Job Number:JB0000219569Franchise Type:Cable
Description:Comcast to proof and pull 266' of fiber through existing conduit. Open trench 5' and set new vault. Restoration per City
of Renton standards.
APPROVED WITH COMMENTS OR REDLINES
Contacts
Name Address PhoneTypeBilling
Comcast Cable Communication
Management & Comcast Cable
B: (215) 665-1700Applicant
Terri Coe
Cannon Construction Inc
B: (253) 922-2787
C: (360) 620-8811
Applicant
Tom Donnelly
Comcast Business Communications
1701 Jfk Blvd, 32nd Floor
Philadelphia, PA 19103
B: (215) 286-7347
C: (215) 286-7557
Contact
Michael Cannon
Cannon Construction Inc
406 Porter Way
Milton, WA 98354-9638
B: (253) 922-2787
C: (253) 588-4034
Contractor
Business License Number: 20838Construction Contractor: CANNOCI055CS
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Laurie Dietz
Comcast - Billing
1701 John F. Kennedy Blvd.
Philadelphia, PA 19103
H: (425) 741-5733Specialized
Billing
X
General Condions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
This permit and plans must be posted at the job site at all times.
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
MFP20000179Scott Warlick1/14/2020RESTORATION PER CITY OF RENTON STANDARDSHolly Powers1/28/2020
DEPARTMENT OF PUBLIC WORKS
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 1 of 2 | Published: 11/25/2019
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN (TCP) APPLICATION
Published: 11/25/2019
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and
obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
TO THE APPLICANT: Submit the TCP application form and required submittal documents to
TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address.
The following items, electronic copies preferred, are all required for submittal of the TCP Application:
1.☐ A copy of the Traffic Control Plan (TCP) Application form.
2.☐ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall:
☐Include map(s) showing the location of the project and work area.
☐Be legible lettering and clear, contrasting, symbols of viewing or printing.
☐Must indicate street names, and north arrow and scale.
☐All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State
Traffic Control Flagger Certification handbook, by the Evergreen Safety Council.
☐Types of plans required:
☐Work hour plan – show all mobility impacts during construction hours.
☐Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
☐Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
☐Pedestrian access/detour plan, if applicable.
Project Name: ______________________________________________ Permit #: _____________________
Project Address: ____________________________________________________________________________
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Description of Work, Work Schedule, Equipment Used: _____________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
Construction Company: ________________________________________ Phone/Cell: (_____) _____-________
Applicant Name: _________________________________ Email: ______________________________________
Business Address: _________________________________ City/State: __________________ Zip: __________
Approved By: _______________________________________________ Date: ________________________
Transportation Operations Engineering
JB0000219569 - Ware-Mill
304 Main Ave S
2/3/2020 2/21/2020 6:30AM 6:30PM
Proof and pull 266' of fiber
through existing conduit.Open trench 5' and set new vault.
Cannon Construction (Terri Coe)360 620 8811
Comcast Cable Communications Management Owen_Shackett@comcast.com
410 Valley Ave NW, STE 12 BLDG C Puyallup, WA 98371
MFP20000179
Monday - Friday
Scott Warlick C.E.D 1/14/2020
9:00am - 3:00pm
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 2 | Published: 11/25/2019
APPLICANT AGREES TO ALL THE FOLLOWING:
•TCP must be approved prior to commencing the work, and all permit conditions shall be met.
•Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner
at a time, with the least possible inconvenience or delay to pedestrians.
•Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or
slippery road conditions during work and non-work hours.
•The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of
traffic. This includes set up within the traveled way or immediately adjacent to the roadway.
•Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures.
•Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including
public transit, to be affected by a temporary lane or road closure.
•TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on
Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT)
and all traffic regulations of the City of Renton and Revised Code of Washington (RCW).
•Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or
Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State
and City codes.
•Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles
and the acts of the Applicant’s agents and employees.
•The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and
in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s
reasonable attorney’s fees and litigation costs incurred resulting from such claim.
•In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay
for legal counsel chosen by the City to defend against same.
•Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
•Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
•Approved Temporary TCP must be at the work site during work hours.
•Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
•Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
•Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations
for vacate parking or curb lane usage.
•Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
•The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site.
•Temporary traffic control devices must be removed immediately when work is done or no construction
activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance
shop (3555 NE 2nd Street; 425-430-7423).
_______________________________ _______________________________ _______________________
Applicant’s Signature Print Name Date
Terri Coe
ROW
ROWROWROWROWROW ROW ROW ROWROWROWROWROWROWROWROWROWROWROW
ROWROWROWROW
ROW
ROWROW
ROWMAIN AVE SHOUSER WAY
S
MAIN AVE S
HOUSER WAY
SS 3RD STROWROWROWROWROWROW ROW ROW ROW ROW
ROWROWROWROW
ROWROW
ROW
ROW
ROWEOPEOPEOPEOPEOPEOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPW21-7 W20-5R W4-2R
FAS EOPWT WT
V V
W21-7
WORK HOURS
6AM-6PM MON-FRI
TRAFFIC CONTROL
PLAN
TEMPORARY SHORT TERM DURATION WORK ZONE
FOR AERIAL SPLICING
TCP NOTES:
1.ALL WORK TO BE PREFORMED DURING DAYTIME HOURS UNLESS TRAFFIC
VOLUMES OR MUNICIPALITY DICTATE OTHERWISE.
2.ALL SIGNS ARE 48"x48" BLACK ON FLUORESCENT ORANGE UNLESS OTHERWISE
NOTED.
3.USE OF SPOTTER TO FACILITATE PEDESTRIAN ACCESS ON 4FT MIN SIDEWALK.
STOP WORK AS NEEDED TO PROVIDE SAFE PASSAGE.
4.MAINTAIN LOCAL ACCESS TO BUSINESSES AND RESIDENTIAL PROPERTIES. ALL
DRIVEWAY ACCESS SHALL REMAIN OPEN DURING DURATION OF WORK.
5.WORK ARE TO INCLUDE STAGING AREA.
[UNDERGROUND WORK] CONTROL TYPE: SINGLE CLOSURE 4-LANE ROAD
PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCE
ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT.
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
200
30SPEED (MPH)
LENGTH (FEET)
25
155 305
35 40
250 425360
45 50
570495
55 60
730
70
645
65
WITH TMA
TYPICAL PROTECTIVE
VEHICLE TYPE
(LBS)
TYPICAL PROTECTIVE VEHICLE
(WITH TMA) LOADED WEIGHT
(FEET)
STATIONARY
OPERATION
FLAT BED, ECT.
4 YARD DUMP TRUCK,
SERVICE TRUCK,IN ACCORDANCE WITH
MINIMUM WEIGHT 15,OOO LBS.
(MAXIMUM WEIGHT SHALL BE
MANUFACTURER RECOMMENDATION)
30 MIN.
A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF
A TMA IS AVAILABLE. IF NO TMA IS USED, THE PROTECTIVE
VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO
SHIELD WORKERS AND NO ROLL AHEAD DISTANCE IS SPECIFIED.
*
SIGN SPACING = X (FEET)
FREEWAYS & EXPRESSWAYS 55/70 MPH (OR AS PER
MUTCD)
1500' + -
60/65 MPH 800' + -RURAL HIGHWAYS
45/55 MPH 500' + -RURAL ROADS
ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMODATE INTERCHANGE RAMPS, AT-GRADE
INTERSECTIONS, AND DRIVEWAYS.
35/40 MPH 350' + -RURAL ROADS & URBAN ARTERIALS
25/30 MPH 200' + - (2)RURAL ROADS, URBAN ARTERIALS
RESIDENTIAL & BUSINESS DISTRICTS
25 MPH OR LESS 100' + - (2)URBAN STREETS
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
MINIMUM TAPER LENGTH IN FEET (L)
(FEET)
LANE
WIDTH POSTED SPEED (MPH)
3025 35 40 45 50 55 60 7065
15010105 270205 500450 -550 --
16511115 295225 550495 660605 --
18012125 320245 600540 720660 840780
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70 40 80
35/45 30 60
25/30 20 40
CANNON CONSTRUCTION CONTACT
Todd Gallant - (253)-468-5971 -
tgallant@cannonconstructioninc.com NROWROWROWROW ROW
ROWROWROWROW ROW ROW ROW ROW ROW ROWROWROWROW ROW ROW
ROWROWROWROWEOP EOP EOP EOP
EOP EOPEOPFL FL FL FL FL FL FL FL FL FL FL
EOPEOPEOPEOPEOPEOPEOPEOPEOPSPOTTERWORK AREA
R2-1
W21-7
OF
DATE REVISION BY QC
CANNON COMPANIES
0000219569WAREMILL
304 Main Ave S
Renton, WA 98057
TCP 1 2
1/10/20 JS TG
COMCAST
MFP20000179
TRAFFIC CONTROL
PLAN
TEMPORARY SHORT TERM DURATION WORK ZONE
FOR UNDERGROUND SPLICING
ROWROWROW ROW
ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW
ROW ROW ROW ROW ROW ROW ROW ROW ROW
EOP EOP EOP EOP EOP EOP EOP EOP EOP
EOP
FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPNW21-7 W20-5R
FAS FLFLFLFLFLFLFLFLFLFLFLFLFLFLVSPOTTERWT
MAIN AVE S
WORK HOURS
6AM-6PM MON-FRI
CANNON CONSTRUCTION CONTACT
Todd Gallant - (253)-468-5971 -
tgallant@cannonconstructioninc.com
TCP NOTES:
1.ALL WORK TO BE PREFORMED DURING DAYTIME HOURS UNLESS
TRAFFIC VOLUMES OR MUNICIPALITY DICTATE OTHERWISE.
2.ALL SIGNS ARE 48"x48" BLACK ON FLUORESCENT ORANGE UNLESS
OTHERWISE NOTED.
3.USE OF SPOTTER TO FACILITATE PEDESTRIAN ACCESS ON 4FT MIN
SIDEWALK. STOP WORK AS NEEDED TO PROVIDE SAFE PASSAGE.
4.MAINTAIN LOCAL ACCESS TO BUSINESSES AND RESIDENTIAL
PROPERTIES. ALL DRIVEWAY ACCESS SHALL REMAIN OPEN DURING
DURATION OF WORK.
5.WORK ARE TO INCLUDE STAGING AREA.
[UNDERGROUD SPLICING] CONTROL TYPE: SINGLE CLOSURE 3-LANE ROAD
PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCE
ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT.
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
200
30SPEED (MPH)
LENGTH (FEET)
25
155 305
35 40
250 425360
45 50
570495
55 60
730
70
645
65
WITH TMA
TYPICAL PROTECTIVE
VEHICLE TYPE
(LBS)
TYPICAL PROTECTIVE VEHICLE
(WITH TMA) LOADED WEIGHT
(FEET)
STATIONARY
OPERATION
FLAT BED, ECT.
4 YARD DUMP TRUCK,
SERVICE TRUCK,IN ACCORDANCE WITH
MINIMUM WEIGHT 15,OOO LBS.
(MAXIMUM WEIGHT SHALL BE
MANUFACTURER RECOMMENDATION)
30 MIN.
A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF
A TMA IS AVAILABLE. IF NO TMA IS USED, THE PROTECTIVE
VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO
SHIELD WORKERS AND NO ROLL AHEAD DISTANCE IS SPECIFIED.
*
SIGN SPACING = X (FEET)
FREEWAYS & EXPRESSWAYS 55/70 MPH (OR AS PER
MUTCD)
1500' + -
60/65 MPH 800' + -RURAL HIGHWAYS
45/55 MPH 500' + -RURAL ROADS
ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMODATE INTERCHANGE RAMPS, AT-GRADE
INTERSECTIONS, AND DRIVEWAYS.
35/40 MPH 350' + -RURAL ROADS & URBAN ARTERIALS
25/30 MPH 200' + - (2)RURAL ROADS, URBAN ARTERIALS
RESIDENTIAL & BUSINESS DISTRICTS
25 MPH OR LESS 100' + - (2)URBAN STREETS
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
MINIMUM TAPER LENGTH IN FEET (L)
(FEET)
LANE
WIDTH POSTED SPEED (MPH)
3025 35 40 45 50 55 60 7065
15010105 270205 500450 -550 --
16511115 295225 550495 660605 --
18012125 320245 600540 720660 840780
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70 40 80
35/45 30 60
25/30 20 40
TRAFFIC CAN EXIT
ON S 2ND ST.
WORK AREA
R2-1
ROWROWROWROWW1-4L
ALLEYW21-7
OF
DATE REVISION BY QC
CANNON COMPANIES
0000219569WAREMILL
304 Main Ave S
Renton, WA 98057
TCP 2 2
1/10/20 JS TG
COMCAST
MFP20000179
1015
315
1025
304
317
910
911907 913909 915 919
901 905
908
903
319 MAIN AVE SHOUS
E
R
W
A
Y
S
S 3RD ST
V
V
V V
70'5'196'5
7
'
12CT
96CT
PROOF & PULL (1) 96CT
FIBER THROUGH EXISTING
OCCUPIED 2" CONDUIT
OPEN TRENCH (2) 2"
CONDUIT & PULL (1)
96CT FIBER THROUGH
LEAVE (1) 150' 96CT
FIBER STORAGE
PULL (1) 12CT FIBER TO
PROPOSED CELL SITE
THROUGH CUSTOMER
PLACED CONDUIT
MEET ME POINT
SET (1) NEW 24"X36" VAULT
& PLACE (1) NEW STRAP
OUT CASE & TRANSITION
FROM 96CT TO 12CT FIBER
TIE INTO EXISTING
SPLICE CASE
SP.WAKV.0543
CUSTOMER TO PLACE
CONDUIT FROM MEET ME
VAULT TO CELL SITE
OF
DATE REVISION BY QC
CANNON COMPANIES
0000219569WAREMILL
304 Main Ave S
Renton, WA 98057
OVERVIEW 2 3
12/16/19 TH TG
COMCAST
N
MFP20000179
Comcast Block created byEvan Wagner, Jun 05, 2014PROPERTY OF COMCASTCOMMUNICATIONS CORP.Contact Curtis Hannah forpermission to use atCurtis_Hannah@cable.comcast.com
Comcast Block created byEvan Wagner, Jun 05, 2014PROPERTY OF COMCASTCOMMUNICATIONS CORP.Contact Curtis Hannah forpermission to use atCurtis_Hannah@cable.comcast.com
V
V
70'5'
196'
5
7
'
TIE INTO EXISTING
SPLICE CASE
SP.WAKV.0543
PROOF & PULL (1) 96CT
FIBER THROUGH EXISTING
OCCUPIED 2" CONDUIT
OPEN TRENCH (2) 2"
CONDUIT & PULL (1)
96CT FIBER THROUGH
SET (1) NEW 24"X36" VAULT
& PLACE (1) NEW STRAP
OUT CASE & TRANSITION
FROM 96CT TO 12CT FIBER
LEAVE (1) 150' 96CT
FIBER STORAGE
PULL (1) 12CT FIBER TO
PROPOSED CELL SITE
THROUGH CUSTOMER
PLACED CONDUIT
N
OF
DATE REVISION BY QC
CANNON COMPANIES
0000219569WAREMILL
304 Main Ave S
Renton, WA 98057
NODE MAP 3 3
12/16/19 TH TG
COMCAST
MFP20000179