Loading...
HomeMy WebLinkAboutMFP20000179.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP20000179 IVR Number: 20000179 Permit Informaon Permit Name:Comcast Cable Franchise Permit Address/Locaon :01/13/2020Application Date:7231500720Parcel Number:304 MAIN AVE S Permit Type:01/28/2020Issue Date:Franchise Permit Work Class:01/27/2021Expiration Date:Minor Utility Job Number:JB0000219569Franchise Type:Cable Description:Comcast to proof and pull 266' of fiber through existing conduit. Open trench 5' and set new vault. Restoration per City of Renton standards. APPROVED WITH COMMENTS OR REDLINES Contacts Name Address PhoneTypeBilling Comcast Cable Communication Management & Comcast Cable B: (215) 665-1700Applicant Terri Coe Cannon Construction Inc B: (253) 922-2787 C: (360) 620-8811 Applicant Tom Donnelly Comcast Business Communications 1701 Jfk Blvd, 32nd Floor Philadelphia, PA 19103 B: (215) 286-7347 C: (215) 286-7557 Contact Michael Cannon Cannon Construction Inc 406 Porter Way Milton, WA 98354-9638 B: (253) 922-2787 C: (253) 588-4034 Contractor Business License Number: 20838Construction Contractor: CANNOCI055CS CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 H: (425) 741-5733Specialized Billing X General Condions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES MFP20000179Scott Warlick1/14/2020RESTORATION PER CITY OF RENTON STANDARDSHolly Powers1/28/2020 DEPARTMENT OF PUBLIC WORKS Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 1 of 2 | Published: 11/25/2019 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN (TCP) APPLICATION Published: 11/25/2019 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. TO THE APPLICANT: Submit the TCP application form and required submittal documents to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address. The following items, electronic copies preferred, are all required for submittal of the TCP Application: 1.☐ A copy of the Traffic Control Plan (TCP) Application form. 2.☐ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall: ☐Include map(s) showing the location of the project and work area. ☐Be legible lettering and clear, contrasting, symbols of viewing or printing. ☐Must indicate street names, and north arrow and scale. ☐All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. ☐Types of plans required: ☐Work hour plan – show all mobility impacts during construction hours. ☐Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. ☐Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. ☐Pedestrian access/detour plan, if applicable. Project Name: ______________________________________________ Permit #: _____________________ Project Address: ____________________________________________________________________________ Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Description of Work, Work Schedule, Equipment Used: _____________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ Construction Company: ________________________________________ Phone/Cell: (_____) _____-________ Applicant Name: _________________________________ Email: ______________________________________ Business Address: _________________________________ City/State: __________________ Zip: __________ Approved By: _______________________________________________ Date: ________________________ Transportation Operations Engineering JB0000219569 - Ware-Mill 304 Main Ave S 2/3/2020 2/21/2020 6:30AM 6:30PM Proof and pull 266' of fiber through existing conduit.Open trench 5' and set new vault. Cannon Construction (Terri Coe)360 620 8811 Comcast Cable Communications Management Owen_Shackett@comcast.com 410 Valley Ave NW, STE 12 BLDG C Puyallup, WA 98371 MFP20000179 Monday - Friday Scott Warlick C.E.D 1/14/2020 9:00am - 3:00pm Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 2 | Published: 11/25/2019 APPLICANT AGREES TO ALL THE FOLLOWING: •TCP must be approved prior to commencing the work, and all permit conditions shall be met. •Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. •Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. •The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of traffic. This includes set up within the traveled way or immediately adjacent to the roadway. •Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures. •Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure. •TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT) and all traffic regulations of the City of Renton and Revised Code of Washington (RCW). •Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State and City codes. •Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Applicant’s agents and employees. •The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. •In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay for legal counsel chosen by the City to defend against same. •Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. •Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. •Approved Temporary TCP must be at the work site during work hours. •Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. •Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: •Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. •Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. •The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site. •Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street; 425-430-7423). _______________________________ _______________________________ _______________________ Applicant’s Signature Print Name Date Terri Coe ROW ROWROWROWROWROW ROW ROW ROWROWROWROWROWROWROWROWROWROWROW ROWROWROWROW ROW ROWROW ROWMAIN AVE SHOUSER WAY S MAIN AVE S HOUSER WAY SS 3RD STROWROWROWROWROWROW ROW ROW ROW ROW ROWROWROWROW ROWROW ROW ROW ROWEOPEOPEOPEOPEOPEOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPW21-7 W20-5R W4-2R FAS EOPWT WT V V W21-7 WORK HOURS 6AM-6PM MON-FRI TRAFFIC CONTROL PLAN TEMPORARY SHORT TERM DURATION WORK ZONE FOR AERIAL SPLICING TCP NOTES: 1.ALL WORK TO BE PREFORMED DURING DAYTIME HOURS UNLESS TRAFFIC VOLUMES OR MUNICIPALITY DICTATE OTHERWISE. 2.ALL SIGNS ARE 48"x48" BLACK ON FLUORESCENT ORANGE UNLESS OTHERWISE NOTED. 3.USE OF SPOTTER TO FACILITATE PEDESTRIAN ACCESS ON 4FT MIN SIDEWALK. STOP WORK AS NEEDED TO PROVIDE SAFE PASSAGE. 4.MAINTAIN LOCAL ACCESS TO BUSINESSES AND RESIDENTIAL PROPERTIES. ALL DRIVEWAY ACCESS SHALL REMAIN OPEN DURING DURATION OF WORK. 5.WORK ARE TO INCLUDE STAGING AREA. [UNDERGROUND WORK] CONTROL TYPE: SINGLE CLOSURE 4-LANE ROAD PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCE ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT. BUFFER DATA LONGITUDINAL BUFFER SPACE = B 200 30SPEED (MPH) LENGTH (FEET) 25 155 305 35 40 250 425360 45 50 570495 55 60 730 70 645 65 WITH TMA TYPICAL PROTECTIVE VEHICLE TYPE (LBS) TYPICAL PROTECTIVE VEHICLE (WITH TMA) LOADED WEIGHT (FEET) STATIONARY OPERATION FLAT BED, ECT. 4 YARD DUMP TRUCK, SERVICE TRUCK,IN ACCORDANCE WITH MINIMUM WEIGHT 15,OOO LBS. (MAXIMUM WEIGHT SHALL BE MANUFACTURER RECOMMENDATION) 30 MIN. A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF A TMA IS AVAILABLE. IF NO TMA IS USED, THE PROTECTIVE VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO SHIELD WORKERS AND NO ROLL AHEAD DISTANCE IS SPECIFIED. * SIGN SPACING = X (FEET) FREEWAYS & EXPRESSWAYS 55/70 MPH (OR AS PER MUTCD) 1500' + - 60/65 MPH 800' + -RURAL HIGHWAYS 45/55 MPH 500' + -RURAL ROADS ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. (1) ALL SPACING MAY BE ADJUSTED TO ACCOMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS. 35/40 MPH 350' + -RURAL ROADS & URBAN ARTERIALS 25/30 MPH 200' + - (2)RURAL ROADS, URBAN ARTERIALS RESIDENTIAL & BUSINESS DISTRICTS 25 MPH OR LESS 100' + - (2)URBAN STREETS (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. MINIMUM TAPER LENGTH IN FEET (L) (FEET) LANE WIDTH POSTED SPEED (MPH) 3025 35 40 45 50 55 60 7065 15010105 270205 500450 -550 -- 16511115 295225 550495 660605 -- 18012125 320245 600540 720660 840780 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 40 80 35/45 30 60 25/30 20 40 CANNON CONSTRUCTION CONTACT Todd Gallant - (253)-468-5971 - tgallant@cannonconstructioninc.com NROWROWROWROW ROW ROWROWROWROW ROW ROW ROW ROW ROW ROWROWROWROW ROW ROW ROWROWROWROWEOP EOP EOP EOP EOP EOPEOPFL FL FL FL FL FL FL FL FL FL FL EOPEOPEOPEOPEOPEOPEOPEOPEOPSPOTTERWORK AREA R2-1 W21-7 OF DATE REVISION BY QC CANNON COMPANIES 0000219569WAREMILL 304 Main Ave S Renton, WA 98057 TCP 1 2 1/10/20 JS TG COMCAST MFP20000179 TRAFFIC CONTROL PLAN TEMPORARY SHORT TERM DURATION WORK ZONE FOR UNDERGROUND SPLICING ROWROWROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPNW21-7 W20-5R FAS FLFLFLFLFLFLFLFLFLFLFLFLFLFLVSPOTTERWT MAIN AVE S WORK HOURS 6AM-6PM MON-FRI CANNON CONSTRUCTION CONTACT Todd Gallant - (253)-468-5971 - tgallant@cannonconstructioninc.com TCP NOTES: 1.ALL WORK TO BE PREFORMED DURING DAYTIME HOURS UNLESS TRAFFIC VOLUMES OR MUNICIPALITY DICTATE OTHERWISE. 2.ALL SIGNS ARE 48"x48" BLACK ON FLUORESCENT ORANGE UNLESS OTHERWISE NOTED. 3.USE OF SPOTTER TO FACILITATE PEDESTRIAN ACCESS ON 4FT MIN SIDEWALK. STOP WORK AS NEEDED TO PROVIDE SAFE PASSAGE. 4.MAINTAIN LOCAL ACCESS TO BUSINESSES AND RESIDENTIAL PROPERTIES. ALL DRIVEWAY ACCESS SHALL REMAIN OPEN DURING DURATION OF WORK. 5.WORK ARE TO INCLUDE STAGING AREA. [UNDERGROUD SPLICING] CONTROL TYPE: SINGLE CLOSURE 3-LANE ROAD PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCE ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT. BUFFER DATA LONGITUDINAL BUFFER SPACE = B 200 30SPEED (MPH) LENGTH (FEET) 25 155 305 35 40 250 425360 45 50 570495 55 60 730 70 645 65 WITH TMA TYPICAL PROTECTIVE VEHICLE TYPE (LBS) TYPICAL PROTECTIVE VEHICLE (WITH TMA) LOADED WEIGHT (FEET) STATIONARY OPERATION FLAT BED, ECT. 4 YARD DUMP TRUCK, SERVICE TRUCK,IN ACCORDANCE WITH MINIMUM WEIGHT 15,OOO LBS. (MAXIMUM WEIGHT SHALL BE MANUFACTURER RECOMMENDATION) 30 MIN. A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF A TMA IS AVAILABLE. IF NO TMA IS USED, THE PROTECTIVE VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO SHIELD WORKERS AND NO ROLL AHEAD DISTANCE IS SPECIFIED. * SIGN SPACING = X (FEET) FREEWAYS & EXPRESSWAYS 55/70 MPH (OR AS PER MUTCD) 1500' + - 60/65 MPH 800' + -RURAL HIGHWAYS 45/55 MPH 500' + -RURAL ROADS ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. (1) ALL SPACING MAY BE ADJUSTED TO ACCOMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS. 35/40 MPH 350' + -RURAL ROADS & URBAN ARTERIALS 25/30 MPH 200' + - (2)RURAL ROADS, URBAN ARTERIALS RESIDENTIAL & BUSINESS DISTRICTS 25 MPH OR LESS 100' + - (2)URBAN STREETS (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. MINIMUM TAPER LENGTH IN FEET (L) (FEET) LANE WIDTH POSTED SPEED (MPH) 3025 35 40 45 50 55 60 7065 15010105 270205 500450 -550 -- 16511115 295225 550495 660605 -- 18012125 320245 600540 720660 840780 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 40 80 35/45 30 60 25/30 20 40 TRAFFIC CAN EXIT ON S 2ND ST. WORK AREA R2-1 ROWROWROWROWW1-4L ALLEYW21-7 OF DATE REVISION BY QC CANNON COMPANIES 0000219569WAREMILL 304 Main Ave S Renton, WA 98057 TCP 2 2 1/10/20 JS TG COMCAST MFP20000179 1015 315 1025 304 317 910 911907 913909 915 919 901 905 908 903 319 MAIN AVE SHOUS E R W A Y S S 3RD ST V V V V 70'5'196'5 7 ' 12CT 96CT PROOF & PULL (1) 96CT FIBER THROUGH EXISTING OCCUPIED 2" CONDUIT OPEN TRENCH (2) 2" CONDUIT & PULL (1) 96CT FIBER THROUGH LEAVE (1) 150' 96CT FIBER STORAGE PULL (1) 12CT FIBER TO PROPOSED CELL SITE THROUGH CUSTOMER PLACED CONDUIT MEET ME POINT SET (1) NEW 24"X36" VAULT & PLACE (1) NEW STRAP OUT CASE & TRANSITION FROM 96CT TO 12CT FIBER TIE INTO EXISTING SPLICE CASE SP.WAKV.0543 CUSTOMER TO PLACE CONDUIT FROM MEET ME VAULT TO CELL SITE OF DATE REVISION BY QC CANNON COMPANIES 0000219569WAREMILL 304 Main Ave S Renton, WA 98057 OVERVIEW 2 3 12/16/19 TH TG COMCAST N MFP20000179 Comcast Block created byEvan Wagner, Jun 05, 2014PROPERTY OF COMCASTCOMMUNICATIONS CORP.Contact Curtis Hannah forpermission to use atCurtis_Hannah@cable.comcast.com Comcast Block created byEvan Wagner, Jun 05, 2014PROPERTY OF COMCASTCOMMUNICATIONS CORP.Contact Curtis Hannah forpermission to use atCurtis_Hannah@cable.comcast.com V V 70'5' 196' 5 7 ' TIE INTO EXISTING SPLICE CASE SP.WAKV.0543 PROOF & PULL (1) 96CT FIBER THROUGH EXISTING OCCUPIED 2" CONDUIT OPEN TRENCH (2) 2" CONDUIT & PULL (1) 96CT FIBER THROUGH SET (1) NEW 24"X36" VAULT & PLACE (1) NEW STRAP OUT CASE & TRANSITION FROM 96CT TO 12CT FIBER LEAVE (1) 150' 96CT FIBER STORAGE PULL (1) 12CT FIBER TO PROPOSED CELL SITE THROUGH CUSTOMER PLACED CONDUIT N OF DATE REVISION BY QC CANNON COMPANIES 0000219569WAREMILL 304 Main Ave S Renton, WA 98057 NODE MAP 3 3 12/16/19 TH TG COMCAST MFP20000179