Loading...
HomeMy WebLinkAboutD_Target_Bathroom_TUPDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT PLANNING DIVISION TIER 1 TEMPORARY USE PERMIT PROJECT NUMBER:LUA20-000028, TP PROJECT NAME:Target Temporary Bathrooms Trailer PROJECT MANAGER:Angelea Weihs, Assoicate Planner APPLICANT:Tim Ryan, Ryan Companies US, Inc. 110 110th Ave NE Suite 100 Bellevue, WA 98004 OWNER:Target Corporation 1000 Nicolett Mall Minneapolis, MN 55403 LOCATION:1215 N LANDING WAY DATE OF DECISION:February 10, 2020 DATE OF EXPIRATION:August 10, 2020 DESCRIPTION:Target Corporation is requesting approval of a Tier 1 Temporary Use Permit for one (1) proposed temporary toilet trailer located at 1215 N Landing Way (parcel number 0886600030). The site is currently occupied by an existing Target store. The applicant is proposing an interior bathroom remodel (building permit number B19004087), with construction activities occurring from approximately March 6th to March 27th of 2020. The proposed trailer (Exhibit 2) will be provided for temporary restroom use for customers (during store hours) during the interior bathroom remodel and will be located on the north side of the building, to the east of the entrance (See Exhibit 1). The proposed trailer is 29 feet long by 8.58 feet wide, and is 11.17 feet tall. The existing family restroom on the interior of the store will remain open for ADA toilet access during the customer bathroom remodel. The Temporary Use Permit is hereby approved. SIGNATURE: DateJennifer Henning, Planning Director DocuSign Envelope ID: 08F60371-B9BF-4FF8-9DDC-0A3D0A4C6243 2/10/2020 | 2:00 PM PST City of Renton Department of Community & Economic Development Administrative Temporary Use Permit LUA20-000028, TPTarget Temporary Bathrooms Trailer Temporary Use Permit Page 2 of 2DECISION DATE: 02/10/2020 RECONSIDERATION: Within 14 days of the decision date, any party may request that the decision be reopened by the approval body. The approval body may modify his decision if material evidence not readily discoverable prior to the original decision is found or if he finds there was misrepresentation or fact. After review of the Reconsideration request, if the approval body finds sufficient evidence to amend the original decision, there will be no further extension of the appeal period. Any person wishing to take further action must file a formal appeal within the 14-day appeal time frame. APPEALS: Appeals of the permit issuance must be filed in writing on or before 5:00 p.m. on February 24, 2020. Appeals must be filed in writing together with the required fee with Hearing Examiner, c/o City Clerk, City of Renton, 1055 South Grady Way, Renton, WA, 98057. Appeals to the Examiner are governed by City of Renton Municipal Code Section 4-8-110. Additional information regarding the appeal process may be obtained from the Renton City Clerk's Office, 425-430-6510. EXPIRATION: A Temporary Use Permit is valid for up to one year from the effective date of the permit, unless the Community & Economic Development Administrator or designee establishes a shorter time frame or an applicant can request that a permit be valid beyond the one year expiration, for up to five years at the time of application or prior to permit expiration. EXTENSIONS: Extension requests do not require additional fees and shall be requested in writing prior to permit expiration to the Department of Community & Economic Development Administrator. DocuSign Envelope ID: 08F60371-B9BF-4FF8-9DDC-0A3D0A4C6243 ACCESSIBLE PATH-OF-TRAVEL TARGET (E) VAN ACCESSIBLE PARKING STALLFOR SIDEWALK PLAN, SEE:ACCESSIBLE PATH-OF-TRAVEL A2015ALL NON-ADA TARGET PARKING TO MATCH EXISTING IN COLOR, LOCATION, AND SIZE. GC TO VERIFY ACCESSIBLE CONFIGURATION MEETS ALL APPLICABLE CODES(E) ADA STALL TO BE CONVERTED TO (N) VAN ACCESSIBLE STALL PER 2015 IBC SECTION 1106.5.FOR STRIPING DETAIL, SEE:TOTAL PARKING STALLS WITHIN TARGET PROPERTY:TOTAL ADA STALLS REQUIRED PER 2015 IBC:NUMBER OF VAN ACCESSIBLE STALLS REQUIRED:NUMBER OF ADA STALLS PROVIDED:NUMBER OF VAN ACCESSIBLE STALLS PROVIDED:47692102G0022ACCESSIBLE PARKING STALL INFORMATIONPROPERTY LINEBUS STOP ACROSS STREET3"7'-0" MINIMUM UNLESS NOTED OTHERWISEVERIFYMINIMUM 1'-0"VERIFYPOST CAPSTAINLESS STEEL FASTENERSWHITE LETTERS AND SYMBOL ON BLUE BACKGROUNDMETAL SIGN BOLT TO STEEL PIPE POSTADDITIONAL SIGN AT VAN ACCESSIBLE PARKING SPACES ONLY2-3/8" OUTER DIAMETER X 8'-0" GALVANIZED PIPE POSTSEALANT ALL AROUND POST6" PIPE-FILL WITH CONCRETE, EXTEND TO 4'-0" ABOVE PAVEMENTRED PLASTIC SLEEVE OVER 6" PIPEASPHALT PAVEMENT12" DIAMETER CONCRETE POST FOOTINGNOTE:1. SIGNAGE PER LOCAL JURISDICTION, VERIFY REQUIREMENTS2. PROVIDE SIGN AT EACH ACCESSIBLE PARKING STALLMIN. 1'-6" UNLESS NOTED OTHERWISE4' - 0"4' - 0"PER LOCAL REQUIREMENTPARKING ONLYVAN ACCESSIBLEVAN ACCESSIBLE SPACE8'-0"VAN ACCESS AISLE WIDTH8'-0"VAN ACCESSIBLE SPACE8'-0"18'-0" MIN.ACCESSIBILITY SIGN, SEE:G0023ACCESSIBLE PARKING STALL SIGNAGE, SEE:G0024(E) ACCESSIBILITY SIGN TO REMAIN22NOTE:PROVIDE AT EACH ACCESSIBLE PARKING STALLCENTER LINE STALLBLUE FIELD BACKGROUND3" WIDE PAINTED STRIPE TRAFFIC LINE WHITE TYPICAL3' - 0"3' - 0"1' - 1"5"2"1' - 0"4"7"3 1/2"10"7"R 9"R 12"TRUE NORTHR1000 NICOLLET MALLMINNEAPOLIS, MN 55403Drawn ByChecked ByProject NumberConfig: RR12/13/2019 9:50:08 AMG002RENTON,WA1215 N LANDING WAYRENTON, WA 98057-5521SITE PLAN(REFERENCE ONLY)CAJGCT-2290NOT TO SCALEG0021SITE PLAN - (REFERENCE ONLY)SCALE:1/2" = 1'-0"G0023ADA ACCESSIBLE PARKING SIGNSCALE:1/4" = 1'-0"G0022ACCESSIBLE VAN STALL LAYOUTSCALE:1 1/2" = 1'-0"G0024ACCESSIBLE PARKING STALLS SIGNAGEFOR REFERENCE ONLYDate No. Description07/25/19 PERMIT ISSUE09/06/19 2 DCN 103165912/12/19 BID ISSUEEXHIBIT 1Target Store Remodel - Temporary Restroom Trailer2. Temporary use permit is for the use of a ExecutiveToilet Trailer to be located on the exterior of the store,adjacent to the front entry. The interior customerbathrooms will be remodeled from 3/6/2020 to3/27/2020 and during that period we are proposing touse an executive toilet trailer for the customers to utilizeduring store hours. The Family restroom on the interior of the store willremain open for ADA Toilet access during the customerbathroom remodel. (E) CART RAILS TO REMAIN, TYP.(E) STOP SIGN TO REMAINACKS TO REMAIN, TYP.F70ASH CONTAINER, TYP.F70TRASH RECEPTACLE,TYP.2F70BOLLARD, ROUNDF70BOLLARD, ROUNDEFS-23, C-1, TYP.30'-0"9'-6" 8'-6 1/2"Temporary Toilet TrailerDocuSign Envelope ID: 08F60371-B9BF-4FF8-9DDC-0A3D0A4C6243 The Gold Suite Series The most impressive unit in our fleet. Our top-of-the-line model offers more generous space, custom oak cabinetry, hardwood doors and trim throughout, imported marble walls, full size porcelain flushing toilets, hot running water and skylights that flood each suite with rich, natural light. • For the Women: 4 Private Stalls and 2 Vanity Sinks • For the Men: 2 Private Stalls, 2 Urinals and 2 Vanity Sinks • Complete with running water, flushing toilets and seat covers • Heater • A/C • Hot and Cold running water • AM/FM CD piped in music • Requires three 110 V, 30 amp plug outlet • Length 29’ x Width 8’7” x Height 11’2” The Gold Suite Let us customize your restroom to match the vision and theme of your event. – 15,000 BTU Air Conditioning with 5600 BTU Heat – 900 Gallon Waste Compartment Tank – 3-30 amp/110 volt electric plugs with power cords – 2 5/16” Hitch – 7 Pin/slot plug with Break Away – 16” tires – Retractable Steel Steps – City water/sewer hookup – Garden Hose Hook-up for water requirement – Good for 2000 uses EXHIBIT 2 Height = 11'2" 8'7" 29' DocuSign Envelope ID: 08F60371-B9BF-4FF8-9DDC-0A3D0A4C6243