HomeMy WebLinkAboutR-408524Ln
00
C)
r)
W
I—
CW
G
0
17
0
W
rr
U
0
J
T
C)
N
J
111
z
z
J
LL
IRRIGATION SCHEDULE
SYMBOL
MANUFACTURER/MODEL/DESCRIPTION
QTY
PSI
HUNTER MP CORNER PROS-00-PRS40
28
40
0
SHRUB ROTATOR, FIXED -RISER, PRESSURE REGULATED
TO 40 PSI 2.76 BARS MP ROTATOR NOZZLE.
T=TURQUOISE AD -ARC 45-105 ON PRS40 BODY.
HUNTER MP STRIP PROS-00-PRS40
9
40
® ®®
SHRUB ROTATOR, FIXED -RISER, PRESSURE REGULATED
LST RST SST
TO 40 PSI 2.76 BARN MP ROTATOR NOZZLE. LST=IVORY
LEFT STRIP, SST=BROWN SIDE STRIP, RST=COPPER
RIGHT STRIP ON PRS40 BODY.
HUNTER MP1000 PROS-00-PRS40
21
40
n
Soo o
SHRUB ROTATOR, FIXED -RISER, PRESSURE REGULATED
TO 40 PSI 2.76 BARN MP ROTATOR NOZZLE. M=MAROON
AD -ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC,
O=OLIVE 360 ARC ON PRS40 BODY.
SYMBOL
MANUFACTURER/MODEL/DESCRIPTION
QTY
PSI
GPM
RADIUS
25 ARC
HUNTER 1-20-00-MPR
8
35
24'
Y
SHRUB ROTOR, FIXED. AD-USTABLE AND FULL CIRCLE.
PLASTIC RISER. DRAIN CHECK VALVE. MPR NOZZLE.
35 ARC
HUNTER 1-20-00-MPR
4
35
34'
Y
SHRUB ROTOR, FIXED. ADEUSTABLE AND FULL CIRCLE.
PLASTIC RISER. DRAIN CHECK VALVE. MPR NOZZLE.
SYMBOL
MANUFACTURER/MODEL/DESCRIPTION
QTY
RAIN BIRD PEB 1"
9
1", 1-1/2", 2" PLASTIC INDUSTRIAL VALVES. LOW FLOW
OPERATING CAPABILITY, GLOBE CONFIGURATION.
BF
FEBCO 825Y 3/4"
REDUCED PRESSURE BACKFLOW PREVENTER
1
WATER METER 1"
1
m
TO BE PROVIDED
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21
44.1 L.F.
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 1/2"
614.2 L.F.
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 3/4"
262.0 L.F.
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 1"
4.2 L.F.
IRRIGATION MAINLINE: PVC SCHEDULE 40 1/2"
81.9 L.F.
IRRIGATION MAINLINE: PVC SCHEDULE 40 3/4"
95.0 L.F.
IRRIGATION MAINLINE: PVC SCHEDULE 40 1"
263.0 L.F.
VaICla CallDit
VaID; NuD Der
❑ ❑ Valia FIDD
ValJa Si []a
F WAS
/�G'
� T i•
O 2_ O
U
�2 20 \�v
�Fn 7202 EXP.
CALCULATED PR (R2)
P10111
S88°56'54"E 28 7' 1
- 3 _ S88°56'54"E 318.87'
— � a
/ 174.62' —
. II
/ � a
� I
co
• J �
C,
CD
34
�
S83°55' 49='E 145.63''WMI
9 6.68 _ I — — — S 3°5
7
II 6
FIRE
I\ T O VALVE i
N T T
1.87 5
� C
G
T I 4 3.99 I
M T Mi; ;
I I--
I
8 5.19 M
1 II T \ I I M T' i /// I I r
\ MCD a
��
,I
CD
I
1
CDf if z
N ,
N � , I
-- -llllll/1//////i//////// I I 0
5-32 10
6 12.1 T� / 1 I� C3 I U
�4 wl
Lo
04
jl / C� C/ /
7 3.25 I (• _
M— — I ' I I i z
1 T \ I I ; I I
I. �\ L34>, U
7la o , I
4"
\'. 3.23 3/4 M L
\ I M/
f I
❑ ° o wtm\\\\ \ O
T 2.67 2 1E I
\ I
I M F. -- \ \\ ��� FH MGf-�1 I I ; ; 1
9 \ \ IIIIIIIIII� ;
1
IRRIGATION
• I ❑ `\ - — — — I I i WM
I VALVE (TYP.)
1
M
L
o � N8 °55'49"W 127 i , I
Ln o) •3
2"W 289.52'
—X
x X
_ —
pJ7TT/7 IT
FF__
11I 1 I
1
�I 1►
third plat esign
1 CITY CORRECTIONS
co-operative
where architecture meets community
304 Alaskan Way S., Suite 301
Seattle, WA 98104 NO. REVISION
BC 11.6.19 SURVEYED: SCALE:
LANKTREE
DESIGNED:
TPDC
DRAWN:
BC
CHECKED:
BC/PH
BY DATE APPR APPROVED:
ONE INCH
AT FULL SCALE
IF NOT ONE IN
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
CITY OF
RENTON
PlanninLBuildin❑/Pudi❑Works Deft.
R-408524
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING
LNathan Janders 01 /03/2020"It'n
CURRENT PLANNING
Matt Herrera 01 /06/2020
WILLOWCREST TOWNHOMES
EDMONDS AVE NE, RENTON, WA
IRRIGATION PLAN AND SCHEDULE
DATE:
07/29/19
FIELDBOOK:
PAGE:
DRAWING NO:
L-2.01
SHEET: OF:
30 35
CM
T
TO
V J
T
Q
J
QD
N
T
C)
(D
d�
7
U)
W
5
0
17
0
C)
W
Ir
U
0
J
i