Loading...
HomeMy WebLinkAboutR-408525Ln 00 C) r) W I— U) CW G O _ z O e ❑❑ e e e O O e LU FINISH GRADE ' 6" VALVE BOX QUICK COUPLING VALVE 1" SCHED. 80 PVC PIPE WITH HOLES FOR "U" BOLT STAINLESS STEEL "U" I BOLT 1/8" MINIMUM STOCK ANCHOR LOW ON VALVE I I 1" U.S. THREADED -ONE -END PVC 2 1/2" CLEAR � u TO TRIPLE SWING COINT NIPPLE [MIPT❑ON "LASCO" OR NOTE: EQUAL PRE -FABRICATED BOX AND ANTI -ROTATION PIPE TRIPLE SWING COINT. NOT REQUIRED FOR INTERIOR LOCATIONS. ELEVATION VIEW PLAN VIEW QUICK COUPLER SCALE: NTS w — III iiil l it O O J w m 73 TURF POP UP HEAD. - z_ 112" MARLEX STREET ELL. � BARB ELL X MIPT. 7\\ 1/2" MARLEX STREET ELL. 7 I PVC TEE SXSXT OR ELL. LATERAL LINE. 4" TO CURB OR WALK, 18" LONG, 1" SCHED. 80 PVC PIPE NOTE: LOCATE VALVE BOX FLUSH IN TURF AREAS 2" ABOVE GRADE IN SHRUB AREAS RECTANGULAR VALVE BOX W/ EXTENSIONS AS REQ'D FINISH GRADE III — 1-1 VALVE NO. TAG 2—� �- GALV NIPPLE 60 QUICK MASTER CONTROL PVC FEMALE ADAPTER COUPP9E. SIZE PER DRAWINGS VALV PVC MAINLINE FLOW PVC MAINLINE 1 CUFT PEA 1 M r I AI GRAVEL — — — — — — — — 1I BRICK SUPPORT MASTER VALVE IS TO BE WIRED TO AUTOMATIC CONTROLLER AS DESIGNATED. CONTROLLER TERMINALS PROVIDED BY THE MANUFACTURER. USE OF WIRE FROM VALVE TO CONTROLLER SAME SIZE AS CONTROL WIRE CALLED OUT IN THE MATERIALS LEGEND. 1/2" POLYETHYLENE FLEXIBLE TUBING, LENGTH AS REQUIRED. TURF SPRAY FLEX ASSEMBLY SCALE: NTS OF WAS/�� a U �2 20 "'02 EXP- MASTER CONTROL VALVE SCALE: NTS MULCH LAYER. PVC LATE L III III III NOTE: — 1 -VERIFY MAX. AND MIN. FLOW RATES. NOTIFY — ARCHITECT IF DIFFERENT FROM MANUFACTURE'S RECOMMENDATIONS. 2FINSTALL PER SPECIFICATIONS AND MANUFACTURE'S RECOMMENDATIONS. 3❑BOX NOT REQUIRED FOR INTERIOR INSTALLATIONS 411PROVIDE VALVE IDENTIFICATION TAG ro"\ AUTOMATIC CONTROL VALVE SCALE: NTS third plac a sign 1 CITY CORRECTIONS e -operative where architecture meets community 304 Alaskan Way S., Suite 301 Seattle, WA 98104 NO. REVISION REMOTE CONTROL VALVE BOX PER SPECIFICATIONS. LID FLUSH WITH FINISHED GRADE OF MULCH. CONTROL WIRES WITH 36" SERVICE COIL AND WATER PROOF WIRE CONNECTIONS, SCH. 80 BALL VALVE SCH. 40 PVC ELL LTA IIV wofoZK•]111Y•]111111111: 1:1 AUTOMATIC CONTROL VALVE BRICK SUPPORT, MIN. TWO PER BOX MESH FILTER PER SPECIFICATIONS INLINE PRESSURE REGULATOR PER SPECIFICATIONS MAINLINE FITTING SCH. 40 MALE ADAPTOR BOTH ENDS. PEA GRAVEL 6" DEPTH. W z_ J Q >_ 00 Ilr,lRLG310N I0'r L_, IOW � 0 3„ (MIN.) —- 6" MIN. II, [Ty P'LA' UNION (TYP.) TO CITY METER STACKED METER SECTION, 6" MIN. FREE BOXES DRAINING GRAVEL NOTES: 1. ALL DOUBLE CHECK VALVE ASSEMBLIES (DCVA's) MUST BE LISTED ON LATEST LIST OF "BACKFLOW PREVENTION ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2. THE OWNER/APPLICANT MUST OBTAIN A SEPARATE CITY OF RENTON PLUMBING PERMIT FOR THE INSPECTION OF THE INSTALLATION OF THE DCVA AND PIPING. THE OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE DCVA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3. THE DCVA MUST BE TESTED BY A STATE CERTIFIED BACKFLOW ASSEMBLY TESTER AFTER ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S EXPENSE. A COPY OF THE TEST REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT., ATTN: WATER UTILITY CROSS —CONNECTION CONTROL SPECIALIST, FAX NO. 425-430-7241. 4. DCVA AND METER BOX SHALL BE LOCATED ON PRINATE, PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. "'T DOUBLE CHECK VALVE STD. PLAN - 340.8 �+.�j� PUBLIC WORKS y ED N:YIFORI IRRIGATION 0A ■� DEPARTMENT �Nzo R ESSIDEN f I FIIuF, EII, ,RINKLE , MARCH 2O10 DOUBLE CHECK VALVE v % SCALE: NTS RUBBER VALVE MARKER FINISH GRADE ? I-1 I I-1 -1 II I II I 2" CLASS 160 PVC SLEEVE MAINLINE III—III- 11=1 16" MIN GALV NIPPLE I �— 3/4" ANGLE VALVE MANUAL DRAIN VALVE SCALE: NTS BC 11.6.19 SURVEYED: LANKTREE DESIGNED: TPDC DRAWN: CHECKED BC/PH BY DATE APPR APPROVED: SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM CITY OF RENTON PlanninE/Buildin❑/PuEli ❑W ks DeEt. NOTE: PROVIDE DIELECTRIC FITTINGS FOR ALL EXISTING 2" IRRIGATION GALVANIZED PIPE METER TO COPPER CONNECTIONS. o W U_ C7 z— Z DOUBLE CHECK VALVE w z ASSEMBLY DCVA N z (D o 0 DRAIN VAVLE MAINLINE TO ISOLATION VALVE, TYP. IRRIGATION VALVES MASTER CONTROLL VALVE POINT OF CONNECTION SCALE: NTS FINISH IRRIGATION GRADE DETECTION TAPE �- N LATERAL I —I I I q—� LINE _ U1 _ 6" _III PRESSURE — MAINLINE —I CONTROL — — WIRES • ALL DIMENSIONS ARE MINIMUM CLEARANCES • NO OTHER TRADES ARE ALLOWED TO USE SAME TRENCH. • ALL IRRIGATION SLEEVING MATERIAL IS TO BE SDR-26, CL 160 PVC PIPE, INSTALLED WITH 18" COVER MIN. • BEDDING FOR SLEEVING MATERIAL SHALL BE SAND. INSTALL 4" BELOW AND 6" ABOVE PIPING. • SLEEVING MATERIAL IS REQUIRED UNDER ALL HARDSCAPE FOR MAINLINES, LATERAL LINES AND IRRIGATION WIRING, SIZING AS CALLED FOR OR IF NOT CALLED OUT, SIZE AS REQUIRED. • NO STACKING A/ERTICALLY❑OF PIPES IN SAME TRENCH. • BACKFILL SHALL BE INSTALLED IN LAYERS, AND MECHANICALLY COMPACTED TO A DRY DENSITY EQUAL TO 9511 OF AD-ACENT UNDISTURBED SOIL. • ALL IRRIGATION IN RIGHT OF WAY TO BE PER CITY STANDARD PLANS. TRENCHING SCALE: NTS LJ IH H • IH Cfl N T C) C) I T 0— W, R-408525 � IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0 z CURRENT PLANNING Matt Herrera 01 /06/2020 O W DATE: WILLOWCREST TOWNHOMES 07/29/19UJ RENTON, WA EDMONDS AVE NE, FIELDBOOK PAGE: O DRAWING NO: J L-2.02 J IRRIGATION DETAILS s"EE31 OF: 35