Loading...
HomeMy WebLinkAboutRC 20200206001079 Instrument Number: 20200206001079 Document:COV Rec: $110.50 Page-1 of 8 Record Date:2/6/2020 2:35 PM Electronically Recorded King County,WA Return Address: City Clerk's Office City of Renton i055 S Grady Way Renton,WA 98057 DECLARATION OF COVENANT FOR INSPECTION AND MAINTENANrE OF DRAINAGE FACILITIES AND ON-SITE f3MPS Grantor: Quadrant Corporation Grantee: City of Renton, a Washin�ton municipal corporation Legal Description: Lot 12 of Lakeview Crest Subdivision Records of King County, Washington, Recording No. 20190705000120 Vol. 289 Page: 19 Assessor's Tax Parcel ID#: 414480-0120 IN CONSIDERATION of the approved City of Renton (checkone o}'the}'ollowin9) ❑✓ Residential Building Permit �Commercial Building Permit ❑Clearing and Grading Permit �Civil Construction or Utility Permit for Permit(s) B 19 0 0 6 6 4 5 (construction/aui�diny/uti�ity vermit#)relating to the real property ("Property") described above, the Grantor(s), the owner(s) in fee of that Property, hereby covenants (covenant)with the City of Renton ("City of Renton" or"City"), a municipal corporation of the state of Washington,that he/she(they)will observe,consent to,and abide by the conditions and obligations set forth and described in Paragraphs 1 through 9 below with regard to the Property, and hereby grants (grant) an easement as described in Paragraphs 2 and 3. Grantor(s) hereby grants(grant),covenants(covenant), and agrees (agree) as follows: 1. The Grantor(s)or his/her(their)successors in interest and assigns("Owners")shall at their own cost,operate, maintain, and keep in good repair,the Property's drainage facilities constructed as required in the approved construction plans and specifications R-3934 (project P�an#) on file with the City of Renton and submitted to the City of Renton for the review and approval of permit(s) U16006676 (Construction/euilding/utilityPermit#).The Property's drainage facilities are shown and/or listed on Exhibit A—Site Plan. The Property's drainage facilities shall be maintained in compliance with the operation and maintenance schedule included and attached herein as Exhibit B—Operations and Maintenance. Drainage facilities include pipes, channels, flow control facilities, water quality facilities, on-site best management practices (BMPs) and other engineered structures designed to manage and/or Page 1 of 8 Instrument Number: 20200206001079 Document:COV Rec: $110.50 Page-2 of 8 Record Date:2/6/2020 2:35 PM King County,WA treat stormwater on the Property. On-site BMPs include dispersion and infiltration devices, bioretention, permeable pavements, rainwater harvesting systems, tree retention credit, reduced impervious surface footprint,vegetated roofs and other measures designed to mimic pre-developed hydrology and minimize stormwater runoff on the Property. 2. Ciiy oT Renion shall have ihe righi io ingress and egress over ihose poriions or ihe Properiy necessary to perform inspections of the stormwater facilities and BMPs and conduct maintenance activitiet specified in this Declaration of Covenant and in accordance with the �enton Municipal Code. City of�enton shall provide at least thirty(30) days' written notice to the Owners that entry on the Property i�planned for the inspection of drainage facilities.After the thirty(30) days,the Owners shall allow the City of P.enton to enter for the sole purpose of inspecting drainage facilities. In lieu of intpection by the City,the Owners may elect to engage a licensed civil engineer registered in the state of Wathington who has expertise in drainage to inspect the drainage facilities and provide a written report describing their condition. If the engineer option is chosen,the Owners shall provide written notice to the City of�enton within fiif�een (i5)days of receivin,g the City's notice o�'inspection.Within thirty(30)days of giving this notice,the Owners,or engineer on behalf of the Owners,shall provide the engineer's report to the City of Renton. If the report is not provided in a timely manner as specified above,the City of Renton may inspect the drainage facilities without further notice. 3. If City of Renton determines from its inspection, or from an engineer's report provided in accordance with Paragraph 2,that maintenance, repair, restoration, and/or mitigation work is required to be done to any of the drainage facilities, City of Renton shall notify the Owners of the specific maintenance, repair, restoration, and/or mitigation work ("Work") required pursuant to the Renton Municipal Code. The City shall also set a reasonable deadline for the Owners to complete the Work, or to provide an engineer's report that verifies completion of the Work. After the deadline has passed, the Owners shall allow the City access to re-inspect the drainage facilities unless an engineer's report has been provided verifying completion of the Work. If the Work is not completed within the time frame set by the City, the City may initiate an enforcement action and/or perform the Work and hereby is given access to the Property for such purposes. Written notice will be sent to the Owners stating the City's intention to perform such Work.This Work will not commence until at least seven(7)days after such notice is mailed. If, within the sole discretion of the City, there exists an imminent or present danger, the seven (7) day notice period will be waived and Work will begin immediately. 4. The Owners shall assume all responsibility for the cost of any Work,or any measures taken by the City to address conditions as described in Paragraph 3. Such responsibility shall include reimbursement to the City within thirty(30)days of the receipt of the invoice for any such Work performed. Overdue payments will require payment of interest at the maximum legal rate allowed by RCW 19.52.020(currently twelve percent (12%)). If the City initiates legal action to enforce this agreement, the prevailing party in such action is entitled to recover reasonable litigation costs and attorney's fees. 5. The Owners are required to obtain written approval from City of Renton prior to filling, piping, cutting, or removing vegetation (except in routine landscape maintenance) in open vegetated stormwater facilities (such as swales, channels, ditches, ponds, etc.), or performing any alterations or modifications to the drainage facilities referenced in this Declaration of Covenant. Page 2 of $ Instrument Number: 20200206001079 Document:COV Rec: $110.50 Page-3 of 8 Record Date:2/6/2020 2:35 PM King County,WA 6, Any notice ar ccansent requireet t�a �a�gi�recr e�r ath�rwise provided fcrr by th� pravisions of this Agreement shafl be e�fective upo� per�on�l defive�y,c�r t�ree(3�days�fter mailir���ry�ertifi+�d Mail, return r�c�Ppt requ�sted. 7. With r�gard te►the rrratt�rs�ddr�ssed her�ir�,this a�reement eonstitut�s the�ntir�agreern�nt b��we�n th� �rarties, and sup�rsedes �I� pr�ar discussicrns, nega�tiatic�ns, �nd all a�reements whatse�ev�r whether c�ral ar written. �, This DecCarat�aan c�f Ccrvenant is intended ta prcat�ct the aalue and desirakrility and promr�te eff6cient and eff�ctive managerr�er�t of surface wat�r drair���e csf the real property describ�d ab�ve, and shafl inur�fia th� b�r��fit c�f ail th� citizens e�f the�ity af Rentor� and its suce�sss�r� and assigns. This C1e�l�ratior� r�f �av�nant sha1� run with tt�� land and be bindin� upr�n Gr�r�t�r(s),�nd f�rant�rr"�{s"}s�ccesscars r"n ir�t�rest,and �s�i�ns. 9. �'his Declar�tFc�n of Cr,venant snay b�termir�atecf by e�ecution c�f a written a�gre�m�nY by� the C?wners and the�ity that is rec�rrded by ECing Cc�unty in ifis reaf p�r�perty records. fN WI7'�tESS W�-4EFtEC3F, this L7ecB�ratir�n e�f �c�v� ant far the Ins�aectic�n and Mai€�ter�ance of C►raina�e F�cilikies is��cecut�d this,,_�day caf d , 2;p�`�,_. C�R�f�T�R,€�wner af the Property � GRAIVTG►R,a��er of the Pt-raperty STATE€�F WAS�1CNEaTCIIV � C4�UPVTY cJF KICVG )ss. Ctn this ciay p�rsca�rally appe�red befc�re me. r " � �" to me kn�wn tc� �re the individu�((s) described in �nd who executed the�uithir� and far�gc�ing instrc�rrrent anr� acknc►wked�ed tha� they si�ned the sam�as the�rfre�e and voluntary act and deeci,farth� uses ar�d purpc�ses therein stated. s �'� c�irr�n urtd�r rr7y h�nd �nd c►€ficial seal this,,,���""day of��`;����.�°'�' , �t� � �� � ���,�•,,a,,'�t��i\64;k��� .�`"��, � �.� � � ��,p�J �'�� �p� t ,� � �,.�����,���r�>4���tr�rer��"����°�, � �. �,. � �j� y �t �° ;���'�`��'f;q�O� °ra����� �f lrt��{� t"Fr�ITI� � �� �5� �' � PVe�tary Pc�blic in and fcarthe�t�te af �, �;. ������, »�, � Vte�shin�tc�n, residirr�at {� pµ ��yp y p�^w"'"� ��p�p�"yA:p.�¢t���"4������4������ ��IWY`�r4" �" Y'..e_.m.e..._e..e.e.M.«�»..�... ...w..«..04. P����t����,1�f��'°�°"4��„�"�'�� �v1Y appointment expires_���"l��"�, _._, Page 3 af� Instrument Number: 20200206001079 Document:COV Rec: $110.50 Page-4 of 8 Record Date:2/6/2020 2:35 PM King County,WA EXHIBIT A - ON-SITE BMP SITE PLAN TOTAL LOT/SITE AREA: 7,021 SF PERMIT #: ADDRESS: 3924 Wells Ave N PARCEL NUMBER: 414480-0120 NEW/REPLACED IMPERV.AREA: 2,685 SF MAX. IMPERV.SURFACE ALLOWED: 3,861.55 SF ON-SITE BMP S USED: D ell for limited filtration, erforated i e connection N 1°51'41"E 58.50' � ?lJ4— -- � `'~�,.. ,. _ --- 1 Q� �?ci—__ i - =^ _=e�+- ..-- _ _. � ^ � _. _ ---- I C)(> <)�� _ - r _ __..._ _ - _ _. i rn co _,., __--- 1 C)4 --- -"�' -- - <�� - ; �t9rm ESMT _ � _____��~�_ I,, ��Ex. Wall �� �V�1LDr� e� a�` ^ �C)- --- -- -- -- -- � � 27-6 Rear S tbac � NOTES: ��, x �,� ; �___Using_Setback av_eragi .g_ � � � 1. THE LIMITS OF �� ��� � i R AC Pad � " � C L E A R I N G A N D - � � 9 SF Patio u o GRADING ARE T�IE o , M � - - - 100 SF �R � Downspout (typ.) LOT LINES. � � " � 35, -= == z 2. MAX. IMPERVIOU � �I12��2 � i',I '-6 COVERAGE � N� i p � i' Roof Overhan N I� PROPOSED i�;l�� 9 W/REDUCED n i , , � � 5�'. ���;�. �i 35 X 51 -4 i'I� � ���� ,. FOOTPRINT 3, � .�, � �,i 1597 SF r i� � ~ 86 .5 " ��I� '��. ��, � x il,.�� o � SF c�'�f z �i � i�� -ROOF-�016--SF ��-- _ N � ��`�..ii ; Window ,� i ��,�. �,�. i � . l �-- �. � ��� , , r�� , i I - �, - � �. N €�P���,,� � w ' Well co _ ��'',��r, � `"'� �,. � - I�{� Y� � .,i 'i 79 SF - M .,, I '^ � c�0 _ , � ;���, � � I I � — � n �� u � � u � - '� � -�'�3 �' x �' ; � ,._ �, orch � �' i';��� Catch ba�in Ti htline t � - Walkw � - ..- -.- 9 � YP•) � 31 y i� Bld En �'� � � 2X�o' Tw ch , Footing Drain (typ.) - /6' � g, � ji 112 SF i;I � Carport Area 136 SF Perfora�ed ,.._._..._ Pipe (De ai� I i ;;; _ T__ — BS L 186 7-6 C.2. C) i �'� I � �'X�' ��,,eu � ; 10-10 '1 � Concrete Drive 560 SF , i 5.5'��e a I R RD � � — 10 MT Sto�m � � — — — — �y,2,P, � �ooting drain aa aa � `� � _--���ta s3 a -_� o I E: 1.�5, ..,, ���F� - , � � ��. _�f___. — =_ ===t�� � � NO °51'41"E 58.50 � �Sidewalk __ _...�__ . _. __ __...__ __ � __ __ � � � i i i � i � �� � � � � ---- __.__. - - ��--h.--_._. _..�_.._.�_..�- --- �' ��x' CL of Wells Ave N RENTON SHORT PLAT LAKEVIEW CREST - LOT 12 � RECORDING / 20190705000120 �� `� VOL. 289 PG. 19 SECTION/TOWNSHIP/RANGE:32-24N-5E ��' �' LAKEVIEW CREST LOT 12 � �eey�a� } APPROVED BY: SCALE: 1"=20' � � � �'�` � ( ;f ��� � TITLE: DATE: � � �.������ � ,�s���,��o,�'��.�:��� � , Instrument Number: 20200206001079 Document:COV Rec: $110.50 Page-5 of 8 Record Date:2/6/2020 2:35 PM King County,WA EXHIBIT B Maintenance Details DRYWELLS FOR LIMITED INFILTRATION (C.2.3.4) Drywells for Limited Infiltration Your property contains a stormwater management flow control BMP (best management practice) called "limited infiltration," which was installed to mitigate the stormwater quantity and quality impacts of some or all of the impervious surfaces on your property. Limited infiltration is a method of soaking runoff from impervious area (such as paved areas and roofs) into the ground. Infiltration devices, such as gravel filled trenches, drywells, and ground surface depressions, facilitate this process by putting runoff in direct contact with the soil and holding the runoff long enough to soak most of it into the ground. To be successful, the soil condition around the infiltration devise must be able to soak water into the ground for a reasonable number of years. The infiltration devices used on your property include the following as indicated on the flow control BMP site plan: ❑ gravel filled trenches, � drywells. The size, placement, and composition of these devices as depicted by the flow control BMP site plan and design details must be maintained and may not be changed without written approval either from the City of Renton or through a future development permit from the City of Renton. Infiltration devices must be inspected annually and after major storm events to identify and repair any physical defects. Maintenance and operation of the system should focus on ensuring the system's viability by preventing sediment-laden flows from entering the device. Excessive sedimentation will result in a plugged or non-functioning facility. If the infiltration device has a catch basin, sediment accumulation must be removed on a yearly basis or more frequently if necessary. Prolonged ponding around or atop a device may indicate a plugged facility. If the device becomes plugged, it must be replaced. Keeping the areas that drain to infiltration devices well swept and clean will enhance the longevity of these devices. For roofs, frequent cleaning of gutters will reduce sediment loads to these devices. Instrument Number: 20200206001079 Document:COV Rec: $110.50 Page-6 of 8 Record Date:2/6/2020 2:35 PM King County,WA PERFORATED PIPE CONNECTION (C.2.11) Your property contains a stormwater management flow control BMP (best management practice) called a "perforated pipe connection," which was installed to reduce the stormwater runoff impacts of some or all of the impervious surface on your property. A perforated pipe connection is a length of drainage conveyance pipe with holes in the bottom, designed to "leak" runoff, conveyed by the pipe, into a gravel filled trench where it can be soaked into the surrounding soil. The connection is intended to provide opportunity for infiltration of any runoff that is being conveyed from an impervious surface (usually a roof) to a local drainage system such as a ditch or roadway pipe system. 1. The size and composition of the perforated pipe connection as depicted by the flow control BMP site plan, Exhibit B, must be maintained and may not be changed without written approval either from the City of Renton or through a future development permit from the City of Renton. 2. The soil overtop of the perforated portion of the system must not be compacted or covered with impervious materials. Instrument Number: 20200206001079 Document:COV Rec: $110.50 Page-7 of 8 Record Date:2/6/2020 2:35 PM King County,WA DRYWELL DETAIL - C.2.2.0 � ROOF CATCH BASIN DOWNSPOUT �•X�� HOUSE FFE:81.16' 2'X 10'TRENCH IE IN:79.72' W/6"PERFORATED PIPE 36"DEEP 12"-78"DIA. � FG:80.96' PVC OR ADS PIPE 8.6'at 1% �9'�t� IN:78.85' WITH DROP IN GRATE ^`;a,;,Y . ?-,. , .. � ,� RO°F IE OUT:79.42 � �'?`�a���^ DOWNSPOUT � 6„PVC �..�,,+•1� � 6"OVERFLOW FLOW PIPE `� � OUTLETPIPECONNECTED TO PUBLIC STORM DRAIN SYSTEM 6"PERFORATED VIA EXISTING LOT DR41N STUB PIPE 7'x 7'SQUARE IE OUT:79.35' DRY WELL HOLE FILLED WITH PLAN VIEW 1�^_3"WASHED NTS DRAIN ROCK IE:77.5' STORM STUB 36"DEEP 12"-18"DIA. ROOF DOWNSPOUT PVC OR ADS PIPE WITH DROP IN GRATE IE OUT: 79.35' RIM:80.87' 2'X 70'TRENCH OF 6"VERTICAL W/6"PERF. RIM:80.8 SEPARATION BETWEEN HOUSE IE IN:79.42' TOPSOIL P�PE INLETANDOUTLET FFE: 81.16' I IN:78.85' � s•OveaF�Ow FG: 80.96' OUTLET PIPE CANNECTED TO PUBLIC STORM DRAIN SYSlEM VIA EXISTING LOT DRAIN SiUB • __ _______ . � • ' '• 1'MIN. ie:�s.5t' FLOW 19'at 3% 8.6'at 1% MIN.6"DIA. PVC PIPE IE:77.5' DOWNTURNED IE OUT:79.42' STORM STUB ELBOW EXTEND STUB AND FINE MESH SCREEN 7'x 7'SQUARE � � CONNECT USING SIDES OF HOLE HOLE FILLED WITH � ry FILLINGSAS NEEDED LINED WITH 1}"-3"WASHED > s CATCH BASIN FILTER FABRIC DRAIN ROCK � 10'TO 15'MIN.AS REQUIRED MIN.1'ABOVE SEASONAL MIN 7' HIGH GROUNDWATER TABLE, SEE SECTION C.2.2.2 � SECTION NTS Instrument Number: 20200206001079 Document:COV Rec: $110.50 Page-8 of 8 Record Date:2/6/2020 2:35 PM King County,WA CONFIGURATIOPI ON SLOPING GROUND ,� �. ��.�. �� �� m� ����,� �.,. ��..� �����. � w�.. w���., ��,.. ��, ,.,,��m .�, �„� �, � DOWNSPOUT WITH CLEANOUT FILTER,SEE DETAIL Ig CLEANOUT PER STD.PLAN 226.00 ��p .,_. ...._,. . _._ ,__.. ..., ry � _, , .,, „_ ,.,..._ .p� . 10'MIN.LEVEL TRENCH WITH . ..._.,,_ .._ �y �-..� PERFORATED PIPE,SEE NOTE 1 � ____ .. . ..... , ..._.._ 5' � _ .__ ... �._' MIN. � � � , _ _��y4 , �..... _._ �' � �,,. ���.„ _____.__�5N _.._�___ Q I� � � IR �.. � _ _. _ � .. .. �__ �.. � � I� �,.... _ �. � � �� .... ..__ _.� _" � ..___� .. � � .._. .._.... ,_ ... ....,�. ..... _....._ G�EANOUTPER I ��g .,_, ._ _.._.. . .... .�.- . STD.PIAN226.00 —�—�...- Iry ...... � ,.. ... ...._ �...... _. � ,., � .��.,�.. ��. � �. w.�.� �� e�, �� � . � �� � TO STORM DRAIN SYSTEM � � �� � �,�� �a �� . . . . ...�. ,.�,. m..�„ .,. ..�„» ..�,,,, �.,s. .�,.m ..�..�...,� �.�„« ..w., .P�.. ».�.. ,,.,,�. .� .w.,,.,.�.».� __. ,_... . .�.._.... _�... _...,._ � _., b ...... . � . �. � FOOTING dRAIN BVPASS I � w. _....., ....,. ����., .._�.... ,�?_ w .m_...,. MSN. MIN. I CLEANOUfPER � -�-- �� STD.PLAN 226.00 Iq �,.....__�...._..~ ... ...._. ._....� _,..,� .._... ._.,... � � ITO STORM DRAIPI SYSTEM � � DOWNSPdUT WITH CLEANOU f �10'MIN.LEVEL TRENCH WITH I„ � RLTER,3EE DETAIL , PERFORATED PIPE,SEE NOTE 1 I� � �« «� ��. ���. ,�.� � �. � ��. �. ��. � � �,� �� ����.�.� ����� � .��W CONFIGUR.4TION ON FLAT GROWND PLAN VIEW OF PARCEL COMPAGTED TOPSOIL OR OTHER CLEAN FILL / �� NON-WOVFN GFOTEXTILE FOR SEPARATION 6"MIN.PVC V' ON TpP ANq SIDES OF TRENCH PER WSpOT PFRFORATFD PIPE SPECIFICATIONS SECTION 9-392(1)TABLE 3 PER ASTM D17R5 s.> �- SOLIDS( .. _____. __ ,,,�,-�� n f,} '�� �.� LEAVES �,��i�� 6 M W\,,,�a-� ,.a r� ` ��� ��"���`t�\� ' �.�\V A\\ti�i ��� �' . Y r� ;t�.e��� .n '�1 r� 7`"' FILTER SCREEN 18"MIN ��� �`�'k'1.G�.��k`�� "���j"�f.��,� t\� (y��� ( l.`'� 1 1l2"-3/4"WASHED � '� �?�"��)Y�`��� "�f ry�^�G„J�� DRAIN ROCK �,.� l �" l,-h f � �°"� �i 2'-5'TO � \� ' S�' ���' >�'r::a�"; ��d�x oRo�wo �\� : � �i'�`��"_�:l�ss��:� I .� , ,�\\ �,�,. �,� � 24"MM.—�-� UNDISTURBED NATIVE SOIL = TYPIGAL DOWNSPOUT MIN.1'ABOVE SEASONAL HIGH FILTER DETAIL GROUNDWATERTABLE SECTION A NOTES: 1. 1RENCH LENG7H TO BE 10 FEE'T IN LENGTH FOR EVERV 5,000 SF OF CONTRIkIUTiN�IMPERVIOUS SURFACE,OR 35,000 SF OF NON-NATIVE PERVIOUS SURFACE,OR PORTION THEREOF. GENERAL NOTES: L WFII_TRATION TRFNCHES I_IMITFD TO ROOF RUNOFF FROM SMGLE.-FAMILY OR DUPLEX HOMES OR TO CONTROL. BASEMEN7 FLOODING. CONSULT WA DEPARTMENT OF ECOLOGY REGULATIONS FOR UNDERGROUND INJECTION CONTRO�PROGRAM(UIC)FOR OTHER TYPES OF RUNOFF MANAGEMENT. 2. IMPERVI6US AREAS LARGER THAN 10,000 SF AND NON-NATNE PERVIOUS AREAS LARC�ER THAN 35,000 SF MAY REC]UIRE LARGER PIPE AND SHOUID BE DESIGNED BY A C�IVIL ENGINEER. 3. THE PERFORATED PIPE MAY NOT BE PLACED IN A CRITICA�AREA BUFFER OR ON SIOPES STEEPER THAN 25%. 4. SEE CGNSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED,DRAWING IS NOTTO SCALE(NTS) STp,PLAN-263.40 � Pueuc woRKs PERFORATED STUB-OUT pPPR ED: °� DEPARTMENT CONNECTION GAZ 9/z$/z018 I DATE