Loading...
HomeMy WebLinkAboutMFP20000627.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP20000627 IVR Number: 20000627 Permit Informaon Permit Name:Puget Sound Energy - ELECTRIC - 601 MONSTER RD SW Address/Locaon :02/12/2020Application Date:2423049008Parcel Number:601 MONSTER RD SW Permit Type:03/04/2020Issue Date:Franchise Permit Work Class:03/04/2021Expiration Date:Minor Utility Job Number:101120691Franchise Type:Electric Description:Puget Sound Energy 101120691 AT GRID 317610 165178 CREW TO PARK IN ROW. AT J01(317588 165175) CREW TO PARK IN ROW AND UPDATES ELBOWS IN EXISTING JBOX . AT J02(317581 165179) CREW TO UPDATE ELBOWS. AT V02A(317581 165179) CREW TO REMOVE MINIPAD AND RELOCATE TRANSFORMER TO V 02B.AT V02B(317580 165178) CREW TO INSTALL NEW VAULT AND TRANSFER SERVICES FROM V 02A. POTHOLE ALL EXISTING UTILITIES. RESTORATION PER CITY OF RENTON STANDARDS . Contacts Name Address PhoneTypeBilling Corrie Rydberg Puget Sound Energy 6905 S 228TH St KENT, WA 98032 C: (425) 892-0416ApplicantX Carli Bunkelman PSE/POTELCO - Billing 6905 S 228th St Kent, WA 98032 B: (253) 437-6708Contact Marita Bond Puget Sound Energy - Billing 6905 S 228th St Kent, WA 98032 B: (253) 395-6346Specialized Billing General Condions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF PUBLIC WORKS Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 1 of 2 | Published: 1ϭ/Ϯϱ/2019 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN (TCP) APPLICATION Published: 1ϭ/Ϯϱ/2019 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. TO THE APPLICANT: Submit the TCP application form and required submittal documents to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address. The following items, electronic copies preferred, are all required for submittal of the TCP Application: 1.܆ A copy of the Traffic Control Plan (TCP) Application form. 2.܆ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall: ܆ Include map(s) showing the location of the project and work area. ܆ Be legible lettering and clear, contrasting, symbols of viewing or printing. ܆ Must indicate street names, and north arrow and scale. ܆ All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. ܆ Types of plans required: ܆ Work hour plan – show all mobility impacts during construction hours. ܆ Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. ܆ Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. ܆ Pedestrian access/detour plan, if applicable. Project Name: ______________________________________________ Permit #: _____________________ Project Address: ____________________________________________________________________________ Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Description of Work, Work Schedule, Equipment Used: _____________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ Construction Company: ________________________________________ Phone/Cell: (_____) _____-________ Applicant Name: _________________________________ Email: ______________________________________ Business Address: _________________________________ City/State: __________________ Zip: __________ Approved By: _______________________________________________ Date: ________________________ Transportation Operations Engineering 4 4 4 4 4 4 4 4 4 4 4 PROLIGIS 601 MONSTER RD SW TBD TBD TBD TBD SEE ATTACHED POTELCO, INC 425 892 0416 DAVE HONEYSETT DAVE.HONEYSETT@PSE.COM 6905 S. 228TH ST KENT, WA 98032 MFP20000627 Scott Warlick C.E.D 2/28/2020 8:00AM - 3:00PMMonday - Friday Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 2 | Published: 1ϭ/Ϯϱ/2019 APPLICANT AGREES TO ALL THE FOLLOWING: x TCP must be approved prior to commencing the work, and all permit conditions shall be met. x Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. x Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. x The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of traffic. This includes set up within the traveled way or immediately adjacent to the roadway. x Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures. x Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure. x TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT) and all traffic regulations of the City of Renton and Revised Code of Washington (RCW). x Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State and City codes. x Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Applicant’s agents and employees. x The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. x In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay for legal counsel chosen by the City to defend against same. x Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. x Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. x Approved Temporary TCP must be at the work site during work hours. x Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. x Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: x Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. x Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. x The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site. x Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street; 425-430-7423). _______________________________ _______________________________ _______________________ Applicant’s Signature Print Name Date CORRIE RYDBERG 02/12/2020 1212 MO N S T E R R D S W OA K E S D A L E A V E S W MONSTER RD SW1311ONLYONLY111316var12ONLY1211121215 1 2 1 1 1313 POLICEUPO THE CREW SHALL CEASE WORK FOR A FLAGGER/SPOTTER TO ESCORT PEDESTRIANS AROUND THE WORK AREA W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4350' 350' 350' W2 0 - 7 AROADWORKAHEADW2 0 - 1 BEPREPAREDTOSTOPW3- 4 350' 350' 350' ROAD WORK AHEAD W20-1W20-7ARIGHT LANE CLOSED AHEAD W20-5R100'100'100'LEFT KEEP R4-8Bmaintain (2) 11' lanesSIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER UNIFORMEDPOLICE OFFICERPOLICE STOP UG BOX/VAULTVault CHEVRONARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY PSE PUGETSOUNDENERGY JOB101120691 601 MONSTER RD SW REVISED 02/04/20 JOHN.CROFOOT@PSE.COM 425-424-6658 SHEET 1 of 4 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. N MFP20000627 1212 MO N S T E R R D S W OA K E S D A L E A V E S W MONSTER RD SW1311ONLYONLY111316var12ONLY1211121215 1 2 1 1 1313 J01 POLICEUPO W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4350' 350' 350' W2 0 - 7 AROADWORKAHEADW2 0 - 1 BEPREPAREDTOSTOPW3- 4 350' 350' 350' RESIDENT(S) WILL BE INFORMED OF POSSIBLE TEMPORARY DRIVEWAY CLOSURE LEFTKEEPR4-8BRIGHTKEEPR4-7Bmaintain (2) 11' lanesROAD WORK AHEAD W20-1W20-7ALEFT LANE CLOSED AHEAD W20-5L100'100'100'SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER UNIFORMEDPOLICE OFFICERPOLICE STOP UG BOX/VAULTVault CHEVRONARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY PSE PUGETSOUNDENERGY JOB101120691 601 MONSTER RD SW REVISED 02/04/20 JOHN.CROFOOT@PSE.COM 425-424-6658 SHEET 2 of 4 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. N MFP20000627 1212 MO N S T E R R D S W OA K E S D A L E A V E S W MONSTER RD SW1311ONLYONLY111316var12ONLY1211121215 1 2 1 1 1313 W20 - 1 ROADWORKAHEADW20-1ROADWORKAHEADJ02 V02A STOP FLAGGER STOP FLAGGERW20-7AW20-4ONE LANEROADAHEADX'X'USE MAXIMUM AVAILABLE SPACE FOR SIGNS W20-7AROAD WORK AHEAD W20-1W20-4ONE LANEROADAHEAD100'100'100'SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER UNIFORMEDPOLICE OFFICERPOLICE STOP UG BOX/VAULTVault CHEVRONARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY PSE PUGETSOUNDENERGY JOB101120691 601 MONSTER RD SW REVISED 02/04/20 JOHN.CROFOOT@PSE.COM 425-424-6658 SHEET 3 of 4 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. N MFP20000627 1212 MO N S T E R R D S W OA K E S D A L E A V E S W MONSTER RD SW1311ONLYONLY111316var12ONLY1211121215 1 2 1 1 1313 ARRW-BRD OTHE R SI D E S/W C L O S E DSIDEWALKCLOSEDR9-9 PLACE SIGN AT BEGINNING OF SIDEWALK ROADWORKAHEADW20-1350' 350' 350'RIGHT LANECLOSEDAHEADW20-5RW4-2LW20 - 1 ROADWORKAHEAD350' PLACE SIGNS ALONG WORK AREAFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PAR K SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER UNIFORMEDPOLICE OFFICERPOLICE STOP UG BOX/VAULTVault CHEVRONARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY PSE PUGETSOUNDENERGY JOB101120691 601 MONSTER RD SW REVISED 02/04/20 JOHN.CROFOOT@PSE.COM 425-424-6658 SHEET 4 of 4 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. N MFP20000627 NO NO NO ABOVE BELOW NOTE ABOVE BELOW NOTEVVCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACT COMPACTCOMPACTCOMPACTCOMPACT COMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTTAG NOTE TAG NOTE COMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTD D D D D D D D 317631-165117 317631-165117 317624-165137 317620-165149 317629-165143 317614-165165 317607-165164 317610-165180 317610-165177 U3378 317610-165178 317609-165178 317609-165178 317609-165178 MON S T E R R D S W MO N S T E R R D S W MONSTER RD SW"610" 317588-165175 317606-165155 317606-165125 750kVA 277/480V N.O. REMOVE 317587-165175 317581-165179 25kVA 120/240V 317580-165178 25kVA 120/240V 317579-165179 SITE PLAN N Vicinity Map N/A Owner / Developer Contact Info officeATTN: PROLOGIS LP 12720 GATEWAY DR, SUITE 110 TUKWILA, WA 98168 JUSTIN KIRK 206-414-7625 OVERHEAD CIRCUIT MAP SCALE: 6" = 1 MILE FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE EAR-15 2019 127 126 116 NEW_A NEW_B NEW_C TTL_A TTL_B TTL_C N/A 108114172 N/A 586029061 N/A 594128518 N/A N/A N/A N/A N/A N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior POWER GENERAL NOTES - COMMERCIAL PROJECT 8. EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. Roads shall be paved or have a compacted , crushed rock base in place. CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them. All work is to be done in accordance with local municipal and county permit requirements as applicable. Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits and crossings from the individual unit's meter base to the designated connection point. Inclement weather conditions may cause delays in construction times and dates. 1. 2. 3. 4. 5. 6. 7. 9. 11. 10. PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" E-Mail: Cell Phone: Project Manager Contact Information: Manager:DAVE HONEYSETT 253-245-0883 DAVE.HONEYSETT@PSE.COM SCALE: 1" = 50'101120691THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP DAVE HONEYSETT 253-245-0883 10/28/19 JUSTIN HANG 253-508-7880 10/28/19 N/A N/A N/A JUSTIN HANG 253-508-7880 10/28/19 REQUIRED CITY OF RENTON PROLOGIS PRIMARY LINE EXTENSION AND SET 2000A CT'S & METERS 601 MONSTER ROAD SW, RENTON, WA 98057 N/A N/A N/A 101120691 N/A 1/2 KING N/A N/A CSPSKEIN T23N, R04E, SEC 24 NW N/A N/A A2304E094 D2305E076 R2304E094 EAR-15 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 101120691 N/A N/A 505955067 N/A JOB SITE SITE SPECIFIC NOTES J01 GRID NUMBER 317588-165175: -EXISTING J-BOX AND VAULT TO REMAIN -REMOVE EXISTING ELBOWS WITH CABLE TAGS AØAFD358, BØAFD359, & CØAFD360 -INSTALL 3 - 12KV ELBOW KITS (6041.1000, ELB10J) -INSTALL CABLE TAGS AØX_______, BØ______, & CØ_______ M01 GRID NUMBER 317587-165175: -POTELCO & PSE METERING DEPARTMENT TO REMOVE ASSOCIATE PRIMARY METER EQUIPMENT -REMOVE EXISTING ELBOWS WITH CABLE TAGS AØAFD358, BØAFD359, & CØAFD360 -REMOVE EXISTING PRIMARY METER CABINET -REMOVE/ABANDON EXISTING PRIMARY METER VAULT & LID PV1 GRID NUMBER317606-165155: -INSTALL 575 VAULT W/ ADJUSTABLE ANTI-SKID COVER LID (6051.1500, SVTDAAS) -INSTALL 3 - 12kV 1/0 AL SOLID SPLICE KIT (6041.2000, SPL10J) -INSTALL CABLE TAGS AØX_______, BØ______, & CØ_______ -INSTALL GRID NUMBERS 317606-165155 V01 GRID NUMBER 317606-165125: -INSTALL 776 VAULT W/ 8' SQ COVER W/ 60" X 24" ACCESS (6045.5000, PM3P15M) -INSTALL 750kVA 277/480V PM TRANSFORMER (MID: 6259300) -INSTALL 3 - 12KV ELBOW KITS (6045.5000, ELB10J) -INSTALL XX' - 4POS SECONDARY CONNECTOR BARS (MID:_______) -INSTALL XX' - CONNECTOR MOUNTAIN BOLT KIT -CONNECT XX - RUNS OF CUSTOMER PROVIDED, OWNED, & MAINTAINED ______ QUAD M02: -PSE METERING DEPARTMENT TO INSTALL 1 - 400A CT'S & METER -PSE METERING DEPARTMENT TO INSTALL 1 - 200A CT'S & METER J02 GRID NUMBER 317579-165179: -REMOVE EXISTING ELBOWS FROM V02A -INSTALL 1 - 12kV ELBOW KIT TOWARDS V02B V02A GRID NUMBER 317581-165179: -RELOCATE EXISTING 25kVA 120/240V PADMOUNT XMFR TO V02B -REMOVE EXISTING MINIPAD HANDHOLE V02B GRID NUMBER 317580-165178: -IINSTALL UNISTRUT MINIPAD HANDHOLE VAULT -TRANSFER & INSTALL 25kVA 120/240V FROM V02A -CONNECT ALL EXISTING SERVICES SPAN SPECIFIC NOTES J01 TO M01: -REMOVE ±80' OF (3) 1/0 AL JKT PRIMARY CABLES J01 TO PV1: -INSTALL ±280' OF 2 - 4" SCHEDULE 80 GREY PVC CONDUIT -INSTALL ±340' OF (3) 1/0 JKT PRIMARY CABLES PV1 TO V01: -INSTALL ±320' OF 2 - 4" SCHEDULE 80 GREY PVC CONDUIT -INSTALL ±380' OF (3) 1/0 JKT PRIMARY CABLES JOB SITE CUSTOMER APPROVAL I approve the location of the trench, including road crossings, and all electrical equipment as shown on print. ________________________ Customer's Signature ________________________ Print Name/Date PRELI MI N A R Y MFP20000627 POTHOLE ALL EXISTING UTILITIES RESTORATION PER CITY OF RENTON STANDARDS