LETTER OF TRANSMITTAL
RJ Development Date: March 3. 2020
401 Central Street SE ESNW No.: ES- 895.06
Olympia, WA 98501 Project: Weatherly Inn
Attn: Mr. Duane Meyer
Email: duane accrete.build
No. of
Copies Date Description
1 2/20-2/28/20 Daily Field Report(s) # 137-141
Comments:
CC:
1:
John Wilson
ATTN:
johnw@rinocon.com
2:
Mark Richardson
ATTN:
mark accrete. build
3:
Jeff Brain
ATTN:
eff accrete. build
4:
Jennifer Vo ele
ATTN:
ennifer accrete.build
5:
Jonathan Chavez
ATTN:
jchavez@rentonwa.gov
6:
Joe W
ATTN-
'oew accrete. build
Transmitted By: Earth Solutions NW, LLC
PM: Scott Riegel, L.G., L.E.G.
15365 NE 90"' Street, Suite 100 Redmond, WA 98052
(425) 449-4704 FAX (425) 449-4711
Earth Solutions NWT«
t 15365 NE 901h Street, Suite 100
Redmond, WA 96052
ESNW Rep.
AK
Project No
0895.06
Page Report No
1/1 137
Date Da of Week
y
Time On Site
Time Off Site
Main (425) 449-4704 1 Fax (425) 449-4711
1:15 PM;
2:15 PM;
Monday
www.esnw corn
3:45 PM
4:00 PM
2/20/20
DAILY FIELD REPORT
Travel Time
Weather
1.25 Hr. RT
40s1F, Clear
Project Name Job Location
Client/Owner
Weatherly Inn 4500 Talbot Rd.
S., Renton, WA i RJ Development,
LLC
Contractor#1
Rino Construction
Contact
Mike
Contact
Field Supervisor
LAC
Reviewed
It* �/�
Contractor #2
Project``'' Manager
5' 1r F
Reviewed
Are approved plans/permits on site?
Project No.
Permit No.
Supplementary Report:
At the client's request, ESNW rep was onsite to observe or test cut slopes, sewer line backfill, test pH of
stormwater, lock and load backfill and earthwork activities.
Cut Slopes
While onsite, rep observed south slopes of the cut slopes to be near vertical and covered in plastic sheeting. Rep
observed that the east slopes of the excavation were near a 0.75:1 (H:V) slope. Although over -steepened, slopes
are stable in current configuration and stable to work within. The contractor is responsible for providing all safety
measures in accordance with state and federal regulation. Rep observed that contractor had sloped the southeast
corner of the footing excavation to a 1:1 (H:V).
Sewer Line Backfill
Rep observed contractor use a medium sized excavator to excavate and install the sewer line. Rep observed
contractor install a 8" PVC pipe at the toe of the excavation (W3'xD5') embedded in a 12" lift pea gravel. Contractor
expressed plans to continue working on sewer line backfill tomorrow, February 25, 2020.
Test pH of Stormwater
Rep took pH tests to determine the pH of stormwater. In the filled baker tanks rep observed 16.4 NTU in a baker
tank. Rep observed that contractor added dry ice to lower the pH level. Rep observed that pH level was contained
onsite at 6.5 pH.
Lock and Load Wall Backfill
Rep observed contractor use a medium sized excavator to place and backfill the lock and load blocks. Rep
observed contactor place geo-grid as per design. Rep will return to take compaction test tomorrow, February 25,
2020.
ESNW rep will return to observe earthwork activities when requested by client
Andrew Kimn, Senior Technician, 206-430-9183
Earth
Solutions
NW u-c
Project Name
Weatherly Inn
Contractor #1
Rino Construction
ontractor #2
Earth Solutions NW«C ESNW Rep.
AK
15365 NE 90'h Street, Suite 100
Redmond, WA 98052 Time On Site
Main (425) 449-4704 1 Fax (425) 449-4711 11:45 AM
www esnw.com
DAILY FIELD REPORT
Travel Time
1.25 Hr. RT
Project No.
Page
Report No.
0895.06
1/1
138
Time Off Site
Date
Day of Week
1:45 PM
2/25/20
Tuesday
Job Location
4500 Talbot Rd. S., Renton, WA
Contact
Mike
Contact
Are approved plans/permits on site? Project No.
Weather
40sOF, Clear
Client/Owner
RJ Development, LLC
Field Supervisor Reviewed ,
LAC L . y/.5
Project Manager Reviewed
S5 V g— �f s
Permit No.
Supplementary Report
At the client's request, ESNW rep was onsite to observe or test cut slopes, lock and load wall backfill and earthwork
activities.
Cut Slopes
While onsite, rep observed south slopes of the cut slopes to be near vertical and covered in plastic sheeting. Rep
observed that the east slopes of the excavation were near a 0.75:1 (H:V) slope. Although over -steepened, slopes
are stable in current configuration and stable to work within. The contractor is responsible for providing all safety
measures in accordance with state and federal regulation. Rep observed that contractor had sloped the southeast
corner of the footing excavation to a 1:1 (H:V).
Lock and Load Wall Backfill
Rep observed contractor use a medium sized excavator to place and backfill the lock and load blocks. Rep
observed contactor place geo-grid as per design. Rep will return to take compaction test tomorrow, February 26,
2020. While onsite, rep met with ESNW manager, Scott, to discuss the installation of the lock and load wall and
the future plans for the rockery installation.
ESNW rep will return to observe earthwork activities when requested by client
-430-9183
Earth Solutions NW«C
15365 NE 90" Street, Suite 100
Redmond, WA 98052
ESNW Rep.
AK
Time On Site
Project No.
0895.06
Time Off Site
Page
1/2
Report No.
139
Date
Day of Week
Main (425) 449-4704 1 Fax (425) 449-4711
Wed
www esnw.com
12:00 PM
12:45 PM
2/26/20
DAILY FIELD REPORT
�ra�e time
Weather
1.25 Hr. RT
40sOF, Clear
Project Name
Job Location
Client/Owner
Weatherly Inn
4500 Talbot Rd.
S., Renton, WA RJ Development,
LLC
Contractor#1
Rino Construction
Contact
Mike
Field Supervisor
LAC
Reviewed
Contractor #2
Contact
Project Manager
Reviewed
-w-3/3
J �59--
Are approved plans/permits on site?
Project No.
Permit No.
Supplementary Report:
the clients request, ESNW rep was onsite to observe or test cut slopes, wall backfill with cement and earthwork
activities.
Cut Slopes
While onsite, rep observed south slopes of the cut slopes to be near vertical and covered in plastic sheeting. Rep
observed that the east slopes of the excavation were near a 0.75:1 (H:V) slope. Although over -steepened, slopes
are stable in current configuration and stable to work within. The contractor is responsible for providing all safety
measures in accordance with state and federal regulation. Rep observed that contractor had sloped the southeast
corner of the footing excavation to a 1:1 (H:V).
Wall Backfill with Cement
Rep observed contractor use a medium sized excavatorto mix and cement treat native brown silty sand with gravel
material. Rep observed contractor treat native material with a 3% cement mix. Rep observed contractor place
12"-18" lifts for a hoe pack and 6"-8" lifts for a jumping jack during compaction. Rep took compaction tests on
backfill and observed material to be adequate of at least 95% of its maximum dry density that was adjusted based
on calculations with the cement treatment (130.7 lbs./cu. ft.).
ESNW rep will return to observe earthwork activities when requested by client
Andrew Kimn, Senior Technician, 206-430-9183
Earth SOililtiOnS NW«C
ES W Rep.
AK
15365 NE 901h Street, Suite 100
Redmond, WA 98052
Time On Site
Main (425) 449-4704 1 Fax (425) 449-4711
www esnw com
12:00 PM
DAILY FIELD REPORT
Travel Time
1.25 Hr. RT
Project Name
Weatherly Inn
Contractor #1
Rino Construction
Contractor #2
Are approved plans/permits on site?
Project No.
Page
2/2
Report No.
0895.06
139
Time Off Site
Date
Day of Week
Wed
12:45 PM
2/26/20
Job Location
4500 Talbot Rd. S , Renton, WA
Contact
Mike
Contact
Project No.
Weather
40s°F, Clear
Client/Owner
RJ Development, LLC
.............. ....._.;
Field Supervisor Reviewed
LAC
Project Manager Reviewed
Ray
Permit No.
Test
Test Location
Reference
Maximum
Fill
Test
% of
Number
(Wall Backfill)
Elevation
Compaction
Dry Density
Moisture
Dry Density
Maximum
Curve
(pcf)
N
(pcf)
Dry Density
122
See map for approximate location
-14'
1
130.7
24.4
124.6
95
123
See map for approximate location
_12'
1
130.7
23.2
123.8
95
Supplementary Report
-
.� ## i •-� �. f
.� Fe F ��
..
. , _. �
--•,i _ may. _ �.. -r• x�` •
r
.... .
r
Earth
Solutions
N W LL(;
Project Name
Weatherly Inn
Contractor #1
Rino Construction
Contractor #2
Earth Solutions NWLLC
15365 NE 901h Street, Suite 100
Redmond, WA 98052
Main (425) 449-4704 1 Fax (425) 449-4711
www.esnw.com
DAILY FIELD REPORT
Are approved plans/permits on site?
Supplementary Report:
ESNW Rep. Project No. Page Report No.
AK 0895.06 1/2 140
Time On Site Time Off Site Date Day of Week
11:45 AM 12:15 PM 2/27/20 Thursday
Travel Time
1.25 Hr. RT
Job Location
4500 Talbot Rd. S., Renton, WA
Contact
Mike
Contact
Project No.
Weather
40s°F, Clear
Client/Owner
RJ Development, LLC
Field
LAC
Project Manager
Permit No.
Reviewed
�
y�
Reviewed
-�13
the client's request, ESNW rep was onsite to observe or test cut slopes, wall backfill with cement, lock and load
wall backfill, test pH of stormwater and earthwork activities.
Cut Slopes
While onsite, rep observed south slopes of the cut slopes to be near vertical and covered in plastic sheeting. Rep
observed that the east slopes of the excavation were near a 0.75:1 (H:V) slope. Although over -steepened, slopes
are stable in current configuration and stable to work within. The contractor is responsible for providing all safety
measures in accordance with state and federal regulation. Rep observed that contractor had sloped the southeast
corner of the footing excavation to a 1:1 (H:V).
Wall Backfill with Cement
Rep observed contractor use a medium sized excavatorto mix and cement treat native brown silty sand with gravel
material. Rep observed contractor treat native material with a 3% cement mix. Rep observed contractor place
12"-18" lifts for a hoe pack and 6"-8" lifts for a jumping jack during compaction. Rep will return to observe and test
the compaction of the wall backfill as needed.
Lock and Load Wall Backfill
Rep observed wall that lock and load wall contractor had completed the wall located between the cast -in -place
wall and the previously constructed lock and load wall. Rep observed contractor grade and place import gray 1/2"
minus crushed recycled concrete in loose—6"--12" lifts. Rep observed contractor place geo-grid as per plan (5XT).
Once lifts were placed, rep observed contractor use a medium sized plate compactor for compaction. Rep took
compaction tests on fill and observed material to be adequate of at least 95% of its maximum dry density (118.4
lbs./cu. ft.). Rep is including compaction tests from previous visits.
Test pH of Stormwater
Rep took pH tests to determine the pH of stormwater. In the filled baker tanks rep observe
of 6.5. Rep observed that pH level was contained onsite at 6.5 pH.
ESNW rep will return to observe earthwork activities when requested by client
Andrew Kimn, Senior Technician, 206-430-9183
r Earth Solutions NWLLC
ES W Rep,
Project No,
Page 2/2
..............
Report No.
0895.06
140
15365 NE 90`" Street, Suite 100
Redmond, WA 98052
Time On Site
Time Off Site
Date
Day of Week
Main (425) 449-4704 1 Fax (425) 449-4711
Thursday
www esnw.com
11:45 AM
12:15 PM
2/27/20
DAILY FIELD REPORT -
Travel Time
1.25 Hr. RT
... .............. ...
Project Name Job Location
Weatherly Inn 4500 Talbot Rd. S., Renton, WA
Contractor #1 Contact
Rino Construction Mike
Contractor #2 Contact
Are approved plans/permits on site? Project No.
Weather
40s'F, Clear
Client/Owner
RJ Development, LLC
Field Supervisor Reviewed
LAC
Project Manager Reviewed
Ray
Permit No.
Test
Test Location
Reference
Maximum
Fill
Test
% of
Number
(Wall Backfill)
Elevation
Compaction
Dry Density
Moisture
Dry Density
Maximum
Curve
(pcf)
(%)
(pcf)
Dry Density
124
See map for approximate location
-61
4
118.4
14.9
112.3
95
125
See map for approximate location
-3'
4
118.4
15.2
111.9
95
126
See map for approximate location
SG
4
118.4
15.0
1 112.1
95
Supplementary Report:
��
L.
�.. T-. � ...� . .,._, ,
... ..
. -
•.., :i� : -see-
�-
aa. •
iti
i
i
1
124, 125,
f
_...
126
Earth Solutions NW«C
15365 NE 90`h Street, Suite 100
Redmond, WA 98052
Main (425) 449-4704 1 Fax (425) 449-4711
www esnw com
DAILY FIELD REPORT
Project Name
Weatherly Inn
Contractor #1
Rino Construction
Contractor #2
Are approved plans/permits on site?
Supplementary Report:
ESNW Rep. Project No. Page
AK 0895.06
Time On Site Time Off Site Date
11:00 AM 1 12:30 PM 1 2/28/20
Travel Time
1.25 Hr. RT
Job Location
4500 Talbot Rd. S., Renton, WA
Contact
Mike
Contact
Project No.
1/1
Weather
40s°F, Clear
Client/Owner
RJ Development, LLC
Field Supervisor Re%
LAC
Project Manager Reu
SS'c�
Permit No
Report No.
141
Day of Week
Friday
cu /
K2
the client's request, ESNW rep was onsite to observe or test cut slopes, wall backfill with cement, footing backfill,
test pH of stormwater and earthwork activities.
Cut Slopes
While onsite, rep observed south slopes of the cut slopes to be near vertical and covered in plastic sheeting. Rep
observed that the east slopes of the excavation were near a 0.75:1 (H:V) slope. Although over -steepened, slopes
are stable in current configuration and stable to work within. The contractor is responsible for providing all safety
measures in accordance with state and federal regulation. Rep observed that contractor had sloped the southeast
corner of the footing excavation to a 1:1 (H:V).
Wall Backfill with Cement
Rep observed contractor use a medium sized excavatorto mix and cement treat native brown silty sand with gravel
material. Rep observed contractor treat native material with a 3% cement mix. Rep observed contractor place
12"-18" lifts for a hoe pack and 6"-8" lifts for a jumping jack during compaction. Rep will return to observe and test
the compaction of the wall backfill as needed.
Footing Backfill
Rep observed contractor using a small or medium sized excavator to backfill the footings. Rep observed contractor
use a jumping jack to compaction material in loose 12" lifts. Rep will return to observe and test the compaction of
the wall backfill as needed.
Test pH of Stormwater
Rep took pH tests to determine the pH of stormwater. In the filled baker tanks rep observed 12.66 NTU and a pH
of 6.5. Rep observed that pH level was contained onsite at 6.5 pH.
ESNW rep will return to observe earthwork activities when requested by client
4-1-11 �_
Andrew Kimn, Senior Technician, 206-430-9183