Loading...
HomeMy WebLinkAboutRC 20200320000469 Instrument Number: 20200320000469 Document:COV Rec: $110.50 Page-1 of 8 Record Date:3/20/2020 10:14 AM Electronically Recorded King County,WA Return Address: City Clerk's Office City of Renton i055 S Grady Way Renton,WA 98057 DECLARATION OF COVENANT FOR INSPECTION AND MAINTENANrE OF DRAINAGE FACILITIES AND ON-SITE f3MPS Grantor: Quadrant Corporation Grantee: City of Renton, a Washin�ton municipal corporation Legal Description: Lot 7 of Lakeview Crest Subdivision Records of King County, Washington, Recording No. 20190705000120 Vol. 289 Page: 19 Assessor's Tax Parcel ID#: 414480-0070 IN CONSIDERATION of the approved City of Renton (checkone o}'the}'ollowin9) ❑✓ Residential Building Permit �Commercial Building Permit ❑Clearing and Grading Permit �Civil Construction or Utility Permit for Permit(s) B2 0 0 0 0 7 0 7 (construction/aui�diny/uti�ityvermit#)relating to the real property ("Property") described above, the Grantor(s), the owner(s) in fee of that Property, hereby covenants (covenant)with the City of Renton ("City of Renton" or"City"), a municipal corporation of the state of Washington,that he/she(they)will observe,consent to,and abide by the conditions and obligations set forth and described in Paragraphs 1 through 9 below with regard to the Property, and hereby grants (grant) an easement as described in Paragraphs 2 and 3. Grantor(s) hereby grants(grant),covenants(covenant), and agrees (agree) as follows: 1. The Grantor(s)or his/her(their)successors in interest and assigns("Owners")shall at their own cost,operate, maintain, and keep in good repair,the Property's drainage facilities constructed as required in the approved construction plans and specifications R-3934 (project P�an#) on file with the City of Renton and submitted to the City of Renton for the review and approval of permit(s) U16006676 (Construction/euilding/utilityPermit#).The Property's drainage facilities are shown and/or listed on Exhibit A—Site Plan. The Property's drainage facilities shall be maintained in compliance with the operation and maintenance schedule included and attached herein as Exhibit B—Operations and Maintenance. Drainage facilities include pipes, channels, flow control facilities, water quality facilities, on-site best management practices (BMPs) and other engineered structures designed to manage and/or Page 1 of 8 Instrument Number: 20200320000469 Document:COV Rec: $110.50 Page-2 of 8 Record Date:3/20/2020 10:14 AM King County,WA treat stormwater on the Property. On-site BMPs include dispersion and infiltration devices, bioretention, permeable pavements, rainwater harvesting systems, tree retention credit, reduced impervious surface footprint,vegetated roofs and other measures designed to mimic pre-developed hydrology and minimize stormwater runoff on the Property. 2. Ciiy oT Renion shall have ihe righi io ingress and egress over ihose poriions or ihe Properiy necessary to perform inspections of the stormwater facilities and BMPs and conduct maintenance activitiet specified in this Declaration of Covenant and in accordance with the �enton Municipal Code. City of�enton shall provide at least thirty(30) days' written notice to the Owners that entry on the Property i�planned for the inspection of drainage facilities.After the thirty(30) days,the Owners shall allow the City of P.enton to enter for the sole purpose of inspecting drainage facilities. In lieu of intpection by the City,the Owners may elect to engage a licensed civil engineer registered in the state of Wathington who has expertise in drainage to inspect the drainage facilities and provide a written report describing their condition. If the engineer option is chosen,the Owners shall provide written notice to the City of�enton within fiif�een (i5)days of receivin,g the City's notice o�'inspection.Within thirty(30)days of giving this notice,the Owners,or engineer on behalf of the Owners,shall provide the engineer's report to the City of Renton. If the report is not provided in a timely manner as specified above,the City of Renton may inspect the drainage facilities without further notice. 3. If City of Renton determines from its inspection, or from an engineer's report provided in accordance with Paragraph 2,that maintenance, repair, restoration, and/or mitigation work is required to be done to any of the drainage facilities, City of Renton shall notify the Owners of the specific maintenance, repair, restoration, and/or mitigation work ("Work") required pursuant to the Renton Municipal Code. The City shall also set a reasonable deadline for the Owners to complete the Work, or to provide an engineer's report that verifies completion of the Work. After the deadline has passed, the Owners shall allow the City access to re-inspect the drainage facilities unless an engineer's report has been provided verifying completion of the Work. If the Work is not completed within the time frame set by the City, the City may initiate an enforcement action and/or perform the Work and hereby is given access to the Property for such purposes. Written notice will be sent to the Owners stating the City's intention to perform such Work.This Work will not commence until at least seven(7)days after such notice is mailed. If, within the sole discretion of the City, there exists an imminent or present danger, the seven (7) day notice period will be waived and Work will begin immediately. 4. The Owners shall assume all responsibility for the cost of any Work,or any measures taken by the City to address conditions as described in Paragraph 3. Such responsibility shall include reimbursement to the City within thirty(30)days of the receipt of the invoice for any such Work performed. Overdue payments will require payment of interest at the maximum legal rate allowed by RCW 19.52.020(currently twelve percent (12%)). If the City initiates legal action to enforce this agreement, the prevailing party in such action is entitled to recover reasonable litigation costs and attorney's fees. 5. The Owners are required to obtain written approval from City of Renton prior to filling, piping, cutting, or removing vegetation (except in routine landscape maintenance) in open vegetated stormwater facilities (such as swales, channels, ditches, ponds, etc.), or performing any alterations or modifications to the drainage facilities referenced in this Declaration of Covenant. Page 2 of $ Instrument Number: 20200320000469 Document:COV Rec: $110.50 Page-3 of 8 Record Date:3/20/2020 10:14 AM King County,WA 6. Ar�y notice c►r ccansent rec{uir�d t� be given or athertnt�se pravided fc�r by the prsavisions of this Agreea�ent sh�tl lae e�fective u�crrr persanaE delivery,r�r t�ree(3)days after rr4ailin�by Certified IVlail, return receipt requested. 7. With regard tc�the rrtatters addr�ss�d her�in,this a�reement cc�nst"rtutes the entire a�reement b�tw��n th� �rartiesk and su�ersec��s �II prFca�° discussir�ns, r►e��a�ia�ic�ns, and �fl a�r�ernen�s whatsc�ever c�vf�e�her or�l or written. S. This Decbaratir�n a�f Cc�venant is intended tc� prmte�t the v�lue anct desirakaility and promc�te effieient and effectiere manag�ment af surface water drainage� of the re�l prcrperty described abe�ve, and sh�61 inur�to the b�nefit nf all tF�e �itizens af xhe City c�f Rentc�n and 'rts�su�cessors and ass�grrs. Th�s 17�clar�ti�n crf �cavenant �ha1f run with tk�� land ancf b� bPnding upc�n �ii'rt�CI4CIC�J�",�l C"#.C1C�VI"�rI"I4CYr°S�SFp�fiJQ.dCG�"'JSCId"S VrY IT1��I��'�"J��rt7Clf.l{�SJ'�I�CI�`J. 9. This L7eclaratian c�f Grsvenant �ay be terrninated b� �xecutir�n crf a writt�n a�reennen� by the C7wners�rtd th�City th�t is rece�rr�ed by ECir�g Cc�unty in Fts rea€ prcrperty records. !6V WI7'IVESS WNEREC7F, this C?ecCara ian of Cov� ant for th� Inspecti�n ar�d Maintenance af C�r�inage Facilities is�xec�ated this__�_.,d�y caf �' ,�,, 2�� daRANTC3F7, awner crf th� Property w. GftAf�TOR,t�wner af the Prc+perty � STAT�C}F 4VASF�f�dGT�IU ) Ct�UNTY C�F lClfVf� �5s. C�n this day persc�nal6y a�rpe�red krefore me: � ' �� �"� tc, me known tc� be the individual(s) described i� and wha exe�uted the uvithin and for�gcrin� irrstrumcnt and ackrrc�wfed�ed that they si�ned�he same as theirfree a�d vcaluntary aet�nd d�ed,fcarth� us��and purpc�ses ther�in st�ted. �� Giv�n ur�d�r rr�y hand and officiaf s�al t6�is �"���`."day crf�G�'�"� ' � ,20 ��" �� � �• � ����,���,w.a4�'k\b t�p��� � � � � �.. �,, ��„P+J �°iq�� ���� �° ,��,�'"��""`������i�ktd��'����d'��� Np-����C.� �_—�-_-`�--�-�,��',�,�,��"7���.,� " ��:���"C��`� °r,,g�,�� �1"f�"lptE..'!.� Tlc�t'Cl�' � �c, ,���� �� ; [Vat�ry Public in and for the�tate of � c�s�;� ������, ��, � VVfashin,�tan, resrdin�at � �� �'i��`,^��°"�,;"'� «'��"��"`�'�.�� �,�.�,,��-�°�a ��`�`� �, � �8��4,�"������.,��9 _____. _�._.�.,�..�__ �gr�1���1��"V�a�����`�� �liy appc�intrr�ent expires ��`""f ""�',, � Pa�e�af� Instrument Number: 20200320000469 Document:COV Rec: $110.50 Page-4 of 8 Record Date:3/20/2020 10:14 AM King County,WA EXHIBIT A — ON—SITE BMP SITE PLAN TOTAL LOT/SITE AREA: 7,298 SF PERMIT #: ADDRESS: 1 1 13 N 39th CT PARCEL NUMBER: 414480-0070 NEW/REPLACED IMPERV.AREA: 2690 SF MAX. IMPERV. SURFACE ALLOWED: 4,013.9 SF ON-SITE BMP S USED: D ell for limited filtration, erforated i e connection �ot Size 7,298 SF N88°49'27"W 69.00' Roof Overhang 2,016 SF — ve — — Paved Areas 674 SF Total Impervious 2690 SF p Impervious 37 9� o O w� �� Lot Size 7,298 SF = .f °�o ,r� Footprint 1597 SF �l� �°� AC Pad � Porch/Carport 167 SF �, �Patio , ��� $F � ��> Total Coverage i�sa sF ^ ��SF 25 Rear Setback �o_o/ �`� Lot Coverage 24 % Z > „�� � � � f Wall Drain 7-6 =_ ..�.-..=._=--�, ��'�I� PROPOSED � Ex. Wall --Tightline (typ.) � _ p,i 35 X 51'-4" i;� � h`� Footin Drain � � 1597 SF i�f Roof Overhan� �; � 9 ���i ROOF=2,016 SF ii�i � A w t I'�i _ i,� � o = N O T E S: `� ,�P)`..� Y �'� � Window i�'. �� �i � 1. THE LIMITS OF �2--_ � .'�� _ r� . --- -�� a�-o ^ CLEARING AND ; � ,� r7 �� N� � o cn ` �_ 7g SF � _.._ A ^ I�— � I� - il� �, � z LOT LINES. � I_ �n _ . �I�-- --- ._._.. 2. MAX. IMPERVIOUS l,_ I 35 _ I�i_.__ Q�YYRS �Ut-- � cov�Rac� E�'— -- '�r��'��- - - i, P -�� I � tx W/REDUCED ;r, � � _ _�typ,_�__ � FOOTPRINT 4,o�3.s s� � � � Buildi g . 31 SF �� ����' --�� 2��0' Trench i Envel pe �� W � /,4'. Carport Area — -- -- W(]IkWy 'i � , Perforated ii A 136 SF � ��112 SF �;� r� ��� o Pipe (Detail .._._.._�.m i, � . _.... � �;�� �� � .2.�.c) 2 BSBL �GSBL -— �/2;�� Concrete Drive c.� 566 SF N �� I ' v 7'x7' Drywell �$� ! ' depth � , J Storm ' 10' ESMT_ _ (detai� - - - - - - - — C.2.2.0 a �= aa aa aa aa =aa _ �,� )-, � �E: Footmg drmn Silt Fence ,. �2% , 69.0' o see std p�an ��_--..—..._ 16 263.4 Sidewalk� �88°4 '27"W 65.54 � R=30.00' ► _ _ L=14.56' N � , o , �-� �� '�° _ ����� Offset Pin A �-�_.._....._�.._.__ -- ----_------� ._ N 39th CT ���� � ' � RENTON SHORT PLAT � RECORDING # 20190705000120 LAKEVIEW CREST — LOT 7 � vo�. 2ss Pc. ,s SECTION/TOWNSHIP/RANGE: 32-24N-5E LAKEVIEW CREST LOT 7 a, APPROVED BY: SCALE: 1"=20' �� � � � C�eCvaki � �� (iq��r ,! "'�""�.�"""�"" "�� � ��� � � TITLE: DATE: � s� �,�, ��Mv ��?u� � �.���� Instrument Number: 20200320000469 Document:COV Rec: $110.50 Page-5 of 8 Record Date:3/20/2020 10:14 AM King County,WA EXHIBIT B Maintenance Details DRYWELLS FOR LIMITED INFILTRATION (C.2.3.4) Drywells for Limited Infiltration Your property contains a stormwater management flow control BMP (best management practice) called "limited infiltration," which was installed to mitigate the stormwater quantity and quality impacts of some or all of the impervious surfaces on your property. Limited infiltration is a method of soaking runoff from impervious area (such as paved areas and roofs) into the ground. Infiltration devices, such as gravel filled trenches, drywells, and ground surface depressions, facilitate this process by putting runoff in direct contact with the soil and holding the runoff long enough to soak most of it into the ground. To be successful, the soil condition around the infiltration devise must be able to soak water into the ground for a reasonable number of years. The infiltration devices used on your property include the following as indicated on the flow control BMP site plan: ❑ gravel filled trenches, � drywells. The size, placement, and composition of these devices as depicted by the flow control BMP site plan and design details must be maintained and may not be changed without written approval either from the City of Renton or through a future development permit from the City of Renton. Infiltration devices must be inspected annually and after major storm events to identify and repair any physical defects. Maintenance and operation of the system should focus on ensuring the system's viability by preventing sediment-laden flows from entering the device. Excessive sedimentation will result in a plugged or non-functioning facility. If the infiltration device has a catch basin, sediment accumulation must be removed on a yearly basis or more frequently if necessary. Prolonged ponding around or atop a device may indicate a plugged facility. If the device becomes plugged, it must be replaced. Keeping the areas that drain to infiltration devices well swept and clean will enhance the longevity of these devices. For roofs, frequent cleaning of gutters will reduce sediment loads to these devices. Instrument Number: 20200320000469 Document:COV Rec: $110.50 Page-6 of 8 Record Date:3/20/2020 10:14 AM King County,WA PERFORATED PIPE CONNECTION (C.2.11) Your property contains a stormwater management flow control BMP (best management practice) called a "perforated pipe connection," which was installed to reduce the stormwater runoff impacts of some or all of the impervious surface on your property. A perforated pipe connection is a length of drainage conveyance pipe with holes in the bottom, designed to "leak" runoff, conveyed by the pipe, into a gravel filled trench where it can be soaked into the surrounding soil. The connection is intended to provide opportunity for infiltration of any runoff that is being conveyed from an impervious surface (usually a roof) to a local drainage system such as a ditch or roadway pipe system. 1. The size and composition of the perforated pipe connection as depicted by the flow control BMP site plan, Exhibit B, must be maintained and may not be changed without written approval either from the City of Renton or through a future development permit from the City of Renton. 2. The soil overtop of the perforated portion of the system must not be compacted or covered with impervious materials. Instrument Number: 20200320000469 Document:COV Rec: $110.50 Page-7 of 8 Record Date:3/20/2020 10:14 AM King County,WA DRYWELL DETAIL - C.2.2.0 � ROOF CATCH BASIN DOWNSPOUT 1'X 1' HOUSE FFE:72.06' 2'X 10'TRENCH IE IN:70.27' W/6"PERFORATED 36"DEEP 12"-18"DIA. � FG:71.56' P�PE PVC OR ADS PIPE 13.97'at 1% �8,�+ IN:69.78' WITH DROP IN GRATE -a�,�4� �, � a DOWNSPol7� IE OUT:7027 ,^r,�^ — 6"PVC - 6"OVERFLOW FLOW PIPE `� � OUTLETPIPECONNECTED TO PUBLIC STORM DRAIN SYSTEM 6"PERFORATED VIA EXISTING LOT DR41N STUB PIPE 7'x 7'SQUARE IE OUT:7028' DRY WELL HOLE FILLED WITH PLAN VIEW 1}"_3"WASHED NTS DRAIN ROCK IE:69.0' STORM STUB 36"DEEP 12"-18"DIA. ROOF DOWNSPOUT PVC OR ADS PIPE WITH DROP IN GRATE IE OUT� 7028' FILTER SCREEN RIM:71.41' 2'X 10'TRENCH MIN. OF 6"VERTICAL PER STD.PLAN 263.4 W/6"PERF. RIM:71.21' SEPARATION BETWEEN TOPSOIL P�PE INLET AND OUTLET HOUSE IE IN:7027' IE IN: � 6"OVERFLOW FFE: 72.06' FG: 71.58' 69�78� OUTLET PIPE CONNECTED TO PUBLIC STORM DRAIN SYSTEM •• "' ' VIA EXISTING LOT DR41N STUB .,.,- .. __ _______ � 1'MIN. IE:70.41� FLOw 16.28'at 3 0 13.97'at 1% MIN.6"DIA. PVC PIPE IE:69.0' DOWNTURNED IE OUT:7027' STORM STUB ELBOW EXTEND STUB AND FINE MESH SCREEN 7'x 7'SQUARE N� CONNECT USING HOLE FILLED WITH W �� FILLINGSASNEEDED SIDES OF HOLE � � LINED WITH 1}"-3"WASHED > s CATCH BASIN FILTER FABRIC DRAIN ROCK �0'ro�5'MIN.ASREQUIRED MIN.1'ABOVESEASONAL MIN7� HIGH GROUNDWATER TABLE, SEE SECTION C222 � SECTION NTS Instrument Number: 20200320000469 Document:COV Rec: $110.50 Page-8 of 8 Record Date:3/20/2020 10:14 AM King County,WA CONFIGURATION ON SLOPING GROUND � � .� ���. �mm� ��d� �.., �A ��� ���� ����� ���.... �� ��� �,µ �� � � DOWNSPOUT WITH CLEANOUT FILTER,SEE DETAIL Ig CLEANOUT PER S7D.PLAN 226.00 Bp ..... _ .....,._ .__ , ... p ,.,__., n, .,.,._...., ,.,..,...,,, 10'MIN.LEVEL TRENGH WITH . .... .. � �p.- 5 PERFORATED PIPE,SEE NOTE 1 � ..,, .., .... ._.._ i . ._... ._.. _ � .... MIN. " � ._. ... ._. _.. .., `` ,_,.. ... � ._ �, ________M5N ____.. Q � I __,., .. ....... ,__ - ._ .... _ '. s. � _ _. __ �..._. � 1 � o � ......_._. .... ...._ ..,. ._.... Ip._._ A `� � IR 10 �...�.,. � � ,... _..... ,, .... _ . , � _._ �,_.... � TPERO � �0. —... -- .� � YSTEM , STb.P�L.AN�228�0, . � � � � � �TO STORM DRAIN S� � a� _ F ' �FOOTING D���'AIN 8V ,,,�.....�., .,...... ».�., �A �,.,.:�. �..._.: .�. �.«„» .I.,.,. ..�..� ��:. r...�. «�-,..��.,..,.� & � . .,w W......� ,..mm ... . _ p ..._.... �.._.. R PASS I4 ..� . _..._. ..._,. , . _,....... __, .._ �...... 5� 5� �J � �--�� �--- .-�-�.. ���� MIN. MIN. I CLEANOUT�PER _.__. _ ._ ._._,h_ � .... ... STD.PLAN 226.00 I� ._...�_.,.._ _..,_ ...... ._._ , , ,..._... .... .....�., _..... ., ; � ITO STqRM DRAIN SYSTEM � � DOWNSPOUT WITH CLEANOU 1" 10'MW.LEVEI.TRENCH WIT�H � � FIITER,SEE DETAIL r PERFORATED PIPE,SEE NOTE 1 I� cm� �. �.. ���. m�.» �,� ��� .�,.,-. �, ��o.��,,, � � �,,.. �.�.. �. � ��... .�..�. � � CONFIGURATION ON FLAT GROUND PLAN VIEW OF PARCEL COMPACTED TOPSOIL OR OTHER CLEAN FILL / �� NON-WOVFN GFOTFXT�LE FOR SEPARATION 6"MIN.PVC V' ON TOP ANp SIDES OF TRENCH PF.R WSDUT PFRFORATFD PIPE SPECIFICATIONS SECTION 9-332(1)TABLE 3 PER ASTM D17$5 ,y--�- �SOLID9l �.����= . `(� '— et '� .,> ,.. LEAVES . 6 MIN\�\� .. ;a "����������i���A�� �',.. ,.V���. .��t-�.�� �� � J c-�y f'r�y 1 ��� 7.e--y 1.�'"� FILTER SCREEN 18"MM ��� '�( �' �,�� k.k('��A`;���"} . „, �'f 11l2"-3l4"WASHED ,.���` ���) �('�`� ,.]��r`�')��� DRAIN ROCK � ,.\`';\�("yq'(?1�°'�''f}��,t�� ��,µ,p}�("�,�(}�_ � 2'-5'TQ ���� � �'C7-�t! � X �"�"�l.;"�"CJ�' GROUND \�`� ��f�1.r"�����x�����„ � .�,�� ,.�"\,�\�,.'.„�24"MIN.—`I UNDISTURBED NATIVE SOIL '> TYPICAL DOWNSPOUT MIN.1'ABOVE SEASONAL HIGH FILTER DETAIL GROUNDWATEft TABLE SEGTION A NOTES: 1. 7RENCH LENGTH 70 BE tU FEET IN LENGTH FOR EVERV 5,600 SF OF CONTRIBUTING IMPERVIOUS 3URFACE,OR 35,000 SF OF NON-NATIVE PERVIOUS SURFACE,OR PORTION THEREOF. GENERAL N�TES: 1. INFIISRATION TRFNCHES LIMITF.�TO ROOF RUNOFF FROM SWGLE-FAMILY OR DUPLFX HOMES OR TO CONTROL. BASEMENT FLOODING. CpNSULT WA DEPARTMENT OF ECOLOGY REGULATIONS FOR UNDERGROUND INJECTION CONTROi.PROGRAM(UIC)FOR OTNER TYPES OF RUNOFF MANAGEMENT. 2. IMPERV�OUS AREAS LAR6ER TMAN 10,000 SF AND NON-NATNE PERVIOUS AREAS LARGER THAN 35,000 SF MAY REQUIRE LARGER PIPE AND SHOULD BE DESIGNED BY A CIVIL ENGINEER. 3. THE PERFORATED PIPE MAV NOT BE PLACED IN A CRITICAL AREA BUFFER OR ON S�OPE5 STEEPER THAN 25%. 4. SEE CONSTRUCTION P�ANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLE55 OTHERWISE NOTED,DRAWING IS NOTTO SCALF.(NTS) STD.PLAN-263.40 � PUBLIC WORKS PERFORATED STUB-OUT APPR ED: °� DEPARTMENT CONNECTION GAZ 9/z�/zp1$ I DATE