Loading...
HomeMy WebLinkAboutMFP20001446.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP20001446 IVR Number: 20001446 Permit Information Permit Name: Comcast Cable Franchise Permit Address/Location:03/28/2020Application Date:8860500140Parcel Number: 2101 DAVIS AVE S Permit Type:04/08/2020Issue Date:Franchise Permit Work Class:04/08/2021Expiration Date:Minor Utility Job Number: 420915Franchise Type:Cable Description: Comcast to bore 112' in the ROW and place 2" PVC. Begin at CATV ped NE corner of 2017's property. Bore 31' then bore 13' under driveway, bore 13' then bore 26' under driveway and continue boring 29' to place a 9" flush mount carson box. Pothole all existing utilities. Restoration per City of Renton standards APPROVED WITH COMMENTS OR REDLINES Contacts Name Address PhoneTypeBilling Fahm Saelee Prince Telecom Applicant Tom Donnelly Comcast Business Communications 1701 Jfk Blvd, 32nd Floor Philadelphia, PA 19103 B: (215) 286-7347 C: (215) 286-7557 Contact Cody Shackett Comcast Cable Communications Contact Akisha Brown Prince Telecom Inc 551A Mews Dr New Castle, DE 19720 B: (302) 482-8893 C: (302) 482-8892 Contractor Business License Number: 29850Electrical Contractor: PRINCTL834BF Construction Contractor: PRINCTL862PS CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 H: (425) 741-5733Specialized Billing X General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES MFP20001446 POTHOLE ALL EXISTING UTILITIES RESTORATION PER CITY OF RENTON STANDARDS Scott Warlick 4/8/2020 MFP20001446 Scott Warlick CED 4/8/2020 MFP20001446 NORTH NOT TO SCALE KENNY"S TRAFFIC ZONE PLANS Kenny StertzLongview , Watraficplayr@aol.com TCS # 5663 cones - S 20th PL Davis Ave SS 21st St Davis Ave SPrince telecom telecommunications installation Fahm Salee 253-891-2899 JOB # CSG420915 <31'>CATVped 2101flagger -20232017carsonset sidewalkDrive way bore <26'>Drive way bore <13'><29'><13'>ROADWORKAHEAD W20-1W20-7aW20-4100'ABC100'100'ONE LANEROADAHEADROADWORKAHEADW20-1W20-7aW20-4100'ABC100'100'ONE LANEROADAHEADNOTES: -Sidewalk shall remain open sidewalkwww.invarion.com MFP20001446