HomeMy WebLinkAboutMFP20001274.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Major Franchise Permit: MFP20001274
IVR Number: 20001274
Permit Information
Permit Name: Comcast Cable Franchise Permit
Address/Location:03/10/2020Application Date:3388200010Parcel Number: 19210 99TH PL S
Permit Type:04/09/2020Issue Date:Franchise
Permit Work Class:04/09/2021Expiration Date:Major Utility
Job Number: JB#198635Franchise Type:Cable
Description: Comcast is proposing to overlash 1226' of 48ct fiber to 10 existing poles. Place new node and upgrade existing
equipment.
Contacts
Name Address PhoneTypeBilling
Stefania Spencer
Sefnco Communications
Applicant
Tom Donnelly
Comcast Business Communications
1701 Jfk Blvd, 32nd Floor
Philadelphia, PA 19103
B: (215) 286-7347
C: (215) 286-7557
Contact
Cody Shackett
Comcast Cable Communications
Contact
Scott Nall
SEFNCO Communications Inc
2904 4th Ave NE
Puyallup, WA 98372
B: (877) 385-2903
C: (253) 444-9057
Contractor
Business License Number: 41108Construction Contractor: SEFNCCI850QD
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Laurie Dietz
Comcast - Billing
1701 John F. Kennedy Blvd.
Philadelphia, PA 19103
H: (425) 741-5733Specialized
Billing
X
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 of 1 | Published: 1/2/2019
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
FRANCHISE PERMIT APPLICATION
Published: 1/2/2019
TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site
Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $630.00. Inspection fee
for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour.
Franchise Agency:
Franchise Job Number: Phone:
Contact Name: Email:
Job Site Address: Project Name:
Description of Work:
Please check all that apply:
☐ New Construction X Repair/Relocate ☐ Underground X Overhead ☐ Sidewalk ☐ Street
☐ Open Trench ☐ Bore # of feet:
Contractor Name: Phone:
State Contractors License #: City of Renton Business License #:
“I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth
under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ”
Signature Date
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at
$125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date Approved as submitted
Pre-Construction Meeting required
Site Construction Inspector Date Approved with comments or redlines
Camera inspection of utilities required
Development Engineering Manager Date
Comcast Cable Communications Management, LLC
253 235-7406
Owen "Cody" Shackett owen_shackett@comcast.com
SEFNCO Communications, Inc.253 999-2271
SEFNCC1850QD Exp. 11/21 BL029666
JB#198635
19012 102nd Ave KV15A New Node WAKTVTH05300
Comcast is proposing to Overlash 1226' 48ct fiber to existing 10 poles. Place new node and upgrade
existing equipment.
3-10-2020
MFP20001274
Scott Warlick 3/17/2020
1501'
DEPARTMENT OF PUBLIC WORKS
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 1 of 2 | Published: 11/25/2019
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN (TCP) APPLICATION
Published: 11/25/2019
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and
obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
TO THE APPLICANT: Submit the TCP application form and required submittal documents to
TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address.
The following items, electronic copies preferred, are all required for submittal of the TCP Application:
1.☐ A copy of the Traffic Control Plan (TCP) Application form.
2.☐ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall:
☐Include map(s) showing the location of the project and work area.
☐Be legible lettering and clear, contrasting, symbols of viewing or printing.
☐Must indicate street names, and north arrow and scale.
☐All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State
Traffic Control Flagger Certification handbook, by the Evergreen Safety Council.
☐Types of plans required:
☐Work hour plan – show all mobility impacts during construction hours.
☐Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
☐Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
☐Pedestrian access/detour plan, if applicable.
Project Name: ______________________________________________ Permit #: _____________________
Project Address: ____________________________________________________________________________
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Description of Work, Work Schedule, Equipment Used: _____________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
Construction Company: ________________________________________ Phone/Cell: (_____) _____-________
Applicant Name: _________________________________ Email: ______________________________________
Business Address: _________________________________ City/State: __________________ Zip: __________
Approved By: _______________________________________________ Date: ________________________
Transportation Operations Engineering
X
X
X
X
X
X
X
X
X
X
X
KV15A New Node WAKTVTH05300
19012 102nd Ave
4-1-20 4-7-20 9:30 A.M.3:30 P.M.
Comcast is proposing to overlash 1226' 48ct fiber to existing 10 poles. Place new node and
upgrade existing equipment.
SEFNCO Communications, Inc
Ashley Kiehn askiehn@sefnco.com
4610 Tacoma Avenue Sumner, WA 98390
MFP20001274
Monday - Friday 9:00am - 3:00pm
Scott Warlick C.E.D 3/17/2020
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 2 | Published: 11/25/2019
APPLICANT AGREES TO ALL THE FOLLOWING:
•TCP must be approved prior to commencing the work, and all permit conditions shall be met.
•Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner
at a time, with the least possible inconvenience or delay to pedestrians.
•Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or
slippery road conditions during work and non-work hours.
•The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of
traffic. This includes set up within the traveled way or immediately adjacent to the roadway.
•Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures.
•Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including
public transit, to be affected by a temporary lane or road closure.
•TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on
Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT)
and all traffic regulations of the City of Renton and Revised Code of Washington (RCW).
•Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or
Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State
and City codes.
•Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles
and the acts of the Applicant’s agents and employees.
•The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and
in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s
reasonable attorney’s fees and litigation costs incurred resulting from such claim.
•In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay
for legal counsel chosen by the City to defend against same.
•Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
•Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
•Approved Temporary TCP must be at the work site during work hours.
•Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
•Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
•Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations
for vacate parking or curb lane usage.
•Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
•The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site.
•Temporary traffic control devices must be removed immediately when work is done or no construction
activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance
shop (3555 NE 2nd Street; 425-430-7423).
_______________________________ _______________________________ _______________________
Applicant’s Signature Print Name Date
Ashley Kiehn 3-10-2020
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP EOP EOP
EOPEOPEOPEOPEOPEOPEOPEOPEOPR/WR/W R/W R/WR/WR/WR/W R/WR/WR/WR/W
R/WR/WR/WR/WR/W
R/WR/W
R/WSE 190TH STDRIVEWAYSIDEWALKPOLE 1102ND AVE SE
SE 190TH STDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYA A A A A A A213'
KV15A NEW NODE WAKTVTH05300
19012 102ND AVE
RENTON, WA
JB# 198635REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSMDD2/13/20Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLANALL CONTROL SET-UP, SIGN SPACING AND PROCEDURESWILL CONFORM TO SPECIFICATIONS STATED IN THEFEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROLDEVICES (M.U.T.C.D)CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSOADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROLWITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OFTHE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF ANDANY SPECIAL CONDITIONS EXISTSPEED253035455055155200250360425495570LONGITUDINAL BUFFER SPACE = BLENGTH4030560657078084010105150205270450500550---11115160225295495550605660--12125180245320540600660720780840LANEWIDTH25303540455055606570MINIMUM TAPER LENGTH IN FEET = LPOSTED SPEED LIMIT (MPH)SITE SPECIFIC TRAFFIC CONTROL PLANSITE NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDE WALK TO REMAIN OPEN. (PEDESRIAN PATH PROVIDED WHERE REQUIRED) AND WILLBE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED.102ND AVE [ PROPOSED WORK AERIAL]CONTROL TYPE: (EXAMPLE - LANE CLOSURE / PEDESTRIAN WITH SPOTTERS)ADVANCE WARNING SPACINGROAD TYPESPEEDFREEWAY/HWYRURAL HWYRURAL ROADRURAL ROAD/URBAN ARTERIALRURAL RD,URBAN ST.,BUS.DISTRICTURBAN STREETS55/7060/6540/5540/5530/2525DISTANCEABCD1500' +/-1500' +/-1500' +/-1500' +/-OR PER MUTCDOR PER MUTCDOR PER MUTCDOR PER MUTCD800' +/-500' +/-350' +/-200' +/-100' +/-800' +/-500' +/-350' +/-200' +/-100' +/-800' +/-500' +/-350' +/-200' +/-100' +/-800' +/-500' +/-350' +/-200' +/-100' +/-TRAFFIC
CONTROL
PLAN-1NOTE:ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING: CEASEWORK, YIELD. WHEN SCHOOL TRANSIT, AND/ORPEDESTRIANS, DEPART: COMMENCE WORK.14CBBEPREPAREDTO STOPROADWORKAHEADLIMITSPEEDR2-125C B
BEPREPAREDTO STOPROADWORKAHEADLIMITSPEEDR2-125CBBEPREPAREDTO STOPROADWORKAHEADFLAGGERFLAGGERFLAGGERFLAGGERNOTE:THIS TCP LAYOUT IS TYPICAL FOR AERIALWORK ON STREET NAME, U.N.O..SPOTTERS AND/OR FLAGGERS TO MOVEAS NEEDED WITH SLOW ROLLING WORKZONE.TRAFFIC CONTROL WILL CONSIST OF SINGLE LANE CLOSUREWITH 2 WAY ALTERNATING TRAFFIC (FLAGGER CONTROLED)SPOTTER*SPOTTER*A
CBBEPREPAREDTO STOP
ROADWORKAHEADAAA
MFP20001274
EOPEOPEOPEOPEOP
EOPEOPEOPEOPEOP EOP
FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLR/WR/WR/WR/WR/W
R/WR/WR/WR/W
R/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W
R/WR/WR/WR/W
R/W
R/WR/WR/WR/WR/WR/WR/WR/WR/W R/WSE 190TH STSE 192TH STPOLE 3POLE 4POLE 8POLE 5EOPDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYCROSSOVERAAAAAAAAAAAAA A A A A A A A A A77'100'156'268'102ND AVE SEA
AAAAAPOLE 7POLE 6AAAAA170'105'
KV15A NEW NODE WAKTVTH05300
19012 102ND AVE
RENTON, WA
JB# 198635REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSMDD2/13/20Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLANALL CONTROL SET-UP, SIGN SPACING AND PROCEDURESWILL CONFORM TO SPECIFICATIONS STATED IN THEFEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROLDEVICES (M.U.T.C.D)CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSOADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROLWITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OFTHE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF ANDANY SPECIAL CONDITIONS EXISTSPEED253035455055155200250360425495570LONGITUDINAL BUFFER SPACE = BLENGTH4030560657078084010105150205270450500550---11115160225295495550605660--12125180245320540600660720780840LANEWIDTH25303540455055606570MINIMUM TAPER LENGTH IN FEET = LPOSTED SPEED LIMIT (MPH)SITE SPECIFIC TRAFFIC CONTROL PLANSITE NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDE WALK TO REMAIN OPEN. (PEDESRIAN PATH PROVIDED WHERE REQUIRED) AND WILLBE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED.102ND AVE [ PROPOSED WORK AERIAL]CONTROL TYPE: (EXAMPLE - LANE CLOSURE / PEDESTRIAN WITH SPOTTERS)ADVANCE WARNING SPACINGROAD TYPESPEEDFREEWAY/HWYRURAL HWYRURAL ROADRURAL ROAD/URBAN ARTERIALRURAL RD,URBAN ST.,BUS.DISTRICTURBAN STREETS55/7060/6540/5540/5530/2525DISTANCEABCD1500' +/-1500' +/-1500' +/-1500' +/-OR PER MUTCDOR PER MUTCDOR PER MUTCDOR PER MUTCD800' +/-500' +/-350' +/-200' +/-100' +/-800' +/-500' +/-350' +/-200' +/-100' +/-800' +/-500' +/-350' +/-200' +/-100' +/-800' +/-500' +/-350' +/-200' +/-100' +/-TRAFFIC
CONTROL
PLAN-2NOTE:ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING: CEASEWORK, YIELD. WHEN SCHOOL TRANSIT, AND/ORPEDESTRIANS, DEPART: COMMENCE WORK.24CBBEPREPAREDTO STOPROADWORKAHEADLIMITSPEEDR2-125CBBEPREPAREDTO STOP
ROADWORKAHEAD
C B
BEPREPAREDTO STOPROADWORKAHEADLIMITSPEEDR2-125CBBEPREPAREDTO STOPROADWORKAHEADFLAGGERFLAGGERFLAGGERFLAGGERNOTE:THIS TCP LAYOUT IS TYPICAL FOR AERIALWORK ON STREET NAME, U.N.O..SPOTTERS AND/OR FLAGGERS TO MOVEAS NEEDED WITH SLOW ROLLING WORKZONE.TRAFFIC CONTROL WILL CONSIST OF SINGLE LANE CLOSUREWITH 2 WAY ALTERNATING TRAFFIC (FLAGGER CONTROLED)SPOTTER*SPOTTER*LEFTKEEPCROSSING WILL BE HANDLED WITH 2SEPARATE SETUPS1AA
AA
MFP20001274
EOPEOPEOPEOPEOP
EOPEOPEOPEOPEOP EOP
FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLR/WR/WR/WR/WR/W
R/WR/WR/WR/W
R/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W
R/WR/WR/WR/W
R/W
R/WR/WR/WR/WR/WR/WR/WR/WR/W R/WSE 190TH STSE 192TH STPOLE 3POLE 4POLE 8POLE 5EOPDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYCROSSOVERAAAAAAAAAAAAA A A A A A A A A A77'100'156'268'102ND AVE SEA
AAAAAPOLE 7POLE 6AAAAA170'105'
KV15A NEW NODE WAKTVTH05300
19012 102ND AVE
RENTON, WA
JB# 198635REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSMDD2/13/20Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLANALL CONTROL SET-UP, SIGN SPACING AND PROCEDURESWILL CONFORM TO SPECIFICATIONS STATED IN THEFEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROLDEVICES (M.U.T.C.D)CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSOADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROLWITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OFTHE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF ANDANY SPECIAL CONDITIONS EXISTSPEED253035455055155200250360425495570LONGITUDINAL BUFFER SPACE = BLENGTH4030560657078084010105150205270450500550---11115160225295495550605660--12125180245320540600660720780840LANEWIDTH25303540455055606570MINIMUM TAPER LENGTH IN FEET = LPOSTED SPEED LIMIT (MPH)SITE SPECIFIC TRAFFIC CONTROL PLANSITE NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDE WALK TO REMAIN OPEN. (PEDESRIAN PATH PROVIDED WHERE REQUIRED) AND WILLBE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED.102ND AVE [ PROPOSED WORK AERIAL]CONTROL TYPE: (EXAMPLE - LANE CLOSURE / PEDESTRIAN WITH SPOTTERS)ADVANCE WARNING SPACINGROAD TYPESPEEDFREEWAY/HWYRURAL HWYRURAL ROADRURAL ROAD/URBAN ARTERIALRURAL RD,URBAN ST.,BUS.DISTRICTURBAN STREETS55/7060/6540/5540/5530/2525DISTANCEABCD1500' +/-1500' +/-1500' +/-1500' +/-OR PER MUTCDOR PER MUTCDOR PER MUTCDOR PER MUTCD800' +/-500' +/-350' +/-200' +/-100' +/-800' +/-500' +/-350' +/-200' +/-100' +/-800' +/-500' +/-350' +/-200' +/-100' +/-800' +/-500' +/-350' +/-200' +/-100' +/-TRAFFIC
CONTROL
PLAN-3NOTE:ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING: CEASEWORK, YIELD. WHEN SCHOOL TRANSIT, AND/ORPEDESTRIANS, DEPART: COMMENCE WORK.34CBBEPREPAREDTO STOPROADWORKAHEADLIMITSPEEDR2-125CBBEPREPAREDTO STOP
ROADWORKAHEAD
C B
BEPREPAREDTO STOPROADWORKAHEADLIMITSPEEDR2-125CBBEPREPAREDTO STOPROADWORKAHEADFLAGGERFLAGGERFLAGGERFLAGGERNOTE:THIS TCP LAYOUT IS TYPICAL FOR AERIALWORK ON STREET NAME, U.N.O..SPOTTERS AND/OR FLAGGERS TO MOVEAS NEEDED WITH SLOW ROLLING WORKZONE.TRAFFIC CONTROL WILL CONSIST OF SINGLE LANE CLOSUREWITH 2 WAY ALTERNATING TRAFFIC (FLAGGER CONTROLED)SPOTTER*SPOTTER*LEFTKEEPCROSSING WILL BE HANDLED WITH 2SEPARATE SETUPS2NOTE:THIS TCP LAYOUT IS TYPICAL FOR AERIALWORK AT A CROSSING. SPOTTERSAND/OR FLAGGERS TO MOVE AS NEEDEDWITH SLOW ROLLING WORK ZONE.AA
AA
MFP20001274
EOPEOPEOPEOPEOPEOPEOP EOPEOPEOP
EOP
EOPEOPEOPEOPFLFLFLFLFL
FL
FL
FL
FLFLFLFLFLFLFLFLFL FLFLFLFLFL
FL
FL
FLFLFLFLFLFLFLFLFLFLR/WR/W R/W R/W R/W R/W
R/WR/WR/WR/W
R/W
R/WR/WR/WR/WPOLE 9POLE 10D
R
I
V
EW
A
Y
DRI
V
E
W
A
YDRIVEWAYDRIVEWAYD
R
I
V
E
W
A
Y
D
R
I
V
EW
A
YAAAAAAAAAAAAAAA
AAA256'99TH PL S DRIVEWAYDRIVEWAYDRIVEWAYSE 192TH STKV15A NEW NODE WAKTVTH05300
19012 102ND AVE
RENTON, WA
JB# 198635REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSMDD2/13/20Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NREVISIONSDATEDESCRIPTIONINITIALTRAFFIC CONTROL PLANALL CONTROL SET-UP, SIGN SPACING AND PROCEDURESWILL CONFORM TO SPECIFICATIONS STATED IN THEFEDERAL MANUAL ON UNIFORMED TRAFFIC CONTROLDEVICES (M.U.T.C.D)CITIES AND VARIOUS MUNICIPALITIES MAY HAVE ALSOADOPTED SEPCIALIZED GUIDLINES FOR TRAFFIC CONTROLWITHIN THEIR JURISDICTION. IT IS THE RESPONSIBILITY OFTHE ON-SITE TRAFFIC CONTROL PERSONAL TO SEE IF ANDANY SPECIAL CONDITIONS EXISTSPEED253035455055155200250360425495570LONGITUDINAL BUFFER SPACE = BLENGTH4030560657078084010105150205270450500550---11115160225295495550605660--12125180245320540600660720780840LANEWIDTH25303540455055606570MINIMUM TAPER LENGTH IN FEET = LPOSTED SPEED LIMIT (MPH)SITE SPECIFIC TRAFFIC CONTROL PLANSITE NOTES:1. MAINTAIN DRIVEWAY ACCESS AT ALL TIMES2. SIDE WALK TO REMAIN OPEN. (PEDESRIAN PATH PROVIDED WHERE REQUIRED) AND WILLBE MONITORED BY A SPOTTER TO INSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED.102ND AVE [ PROPOSED WORK AERIAL]CONTROL TYPE: (EXAMPLE - LANE CLOSURE / PEDESTRIAN WITH SPOTTERS)ADVANCE WARNING SPACINGROAD TYPESPEEDFREEWAY/HWYRURAL HWYRURAL ROADRURAL ROAD/URBAN ARTERIALRURAL RD,URBAN ST.,BUS.DISTRICTURBAN STREETS55/7060/6540/5540/5530/2525DISTANCEABCD1500' +/-1500' +/-1500' +/-1500' +/-OR PER MUTCDOR PER MUTCDOR PER MUTCDOR PER MUTCD800' +/-500' +/-350' +/-200' +/-100' +/-800' +/-500' +/-350' +/-200' +/-100' +/-800' +/-500' +/-350' +/-200' +/-100' +/-800' +/-500' +/-350' +/-200' +/-100' +/-TRAFFIC
CONTROL
PLAN-4NOTE:ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING: CEASEWORK, YIELD. WHEN SCHOOL TRANSIT, AND/ORPEDESTRIANS, DEPART: COMMENCE WORK.44BEPREPAREDTO STOPCBONELANEROADAHEADROADWORKAHEADLIMITSPEEDR2-125B ABEPREPAREDTO STOPROADWORKAHEADLIMITSPEEDR2-125BBBEPREP
A
R
E
D
TO ST
O
P
ONE
LANEROA
D
AHEA
D FLAGGERFLAGGERFLAGGERNOTE:THIS TCP LAYOUT IS TYPICAL FOR AERIALWORK ON STREET NAME, U.N.O..SPOTTERS AND/OR FLAGGERS TO MOVEAS NEEDED WITH SLOW ROLLING WORKZONE.TRAFFIC CONTROL WILL CONSIST OF SINGLE LANE CLOSUREWITH 2 WAY ALTERNATING TRAFFIC (FLAGGER CONTROLED)SPOTTER*SPOTTER*NOTE:THIS TCP LAYOUT IS TYPICAL FOR AERIALWORK AT A CROSSING. SPOTTERSAND/OR FLAGGERS TO MOVE AS NEEDEDWITH SLOW ROLLING WORK ZONE.ROA
D
WOR
K
AHEA
D BBABMFP20001274
SEFNCOCOMMUNICATIONS AERIAL FIBER INSTALLATIONCOMCASTKV15A NEW NODE WAKTVTH0530019012 102ND AVEJB# 198635MFP20001274
POLE 1
POLE
2
POLE
3
POLE
4POLE 8POLE 9POLE 10
POLE
5
CRO
SSO
VER AAAAAAAAAAAAAAA
AAAAAA
A
A
A
AAAAAAAAA
A A A A A A A A A A A A A A A A A A A A A A A A A A
A
AAAAAPOLE 7
POLE
6AAAAAKV15A NEW NODE WAKTVTH05300
19012 102ND AVE
RENTON, WA
JB# 198635REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSMDD2/13/20VICINITY MAPBEGINEND47.431699, -122.20510047.430142, -122.207944102ND AVE SE &SE 190TH STSE 192ND ST &99TH PL SPERMITTINGCOMCASTASHLEY KIEHN253-999-22714610 TACOMA AVESUMNER, WA 98104ASKIEHN.SEFNCO.COMSEFNCOCONTACTSPG#SHEET INDEX1COVER SHEET2VICINITY MAP, CONTACTS & SHEET INDEX3GENERAL NOTES4LEGEND5-7SITE-PLAN72N/AN/ADECRIPTION OF WORKTOTALOVERLASH 48CT FIBER1226LFTOTAL:1226LFPUYALLUP, WA 98371EMAIL: AARON_CANTRELL@COMCAST.COMPHONE: 206-510-4225410 VALLEY AVEAARON CANTRELLJAMIE COLLINS410 TACOMA AVESUMNER, WA 98104PHONE:253-797-1936EMAIL: JAMIECOLLINS@SEFNCO.COMVICINITY MAPMFP200012741501'
KV15A NEW NODE WAKTVTH05300
19012 102ND AVE
RENTON, WA
JB# 198635REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSMDD2/13/20GENERAL NOTES7REVISIONSDATEDESCRIPTIONINITIAL3N/AN/ATHE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBY DISCLAIMS ANYRESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION. PERSONS WORKING IN THE AREACOVERED BY THIS DRAWING MUST CONTACT THE STATEWIDE CALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THELOCATION OF UNDERGROUND UTILITIES PRIOR TO PERFORMING ANY EXCAVATION.1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEEDSITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LOCAL JURISDICTIONREGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEENTHESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARDSHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIRE INSPECTED AND APPROVED BYTHE LOCAL JURISDICTION INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BEPROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.2.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTINGUTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON ASBEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THECONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTIONPOINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TORELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESEPLANS.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLEAGENCIES. THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTOR AT LEAST 48 HOURS PRIORTO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLICIMPROVEMENTS IF REQUIRED.4.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALL UTILITYCOMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURINGCONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUMDISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIESAFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THEAPPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSIONAGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO:EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.7.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HISSUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOTIDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEERIMMEDIATELY.8.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD,UNLESS SPECIFICALLY STATED OTHERWISE.9.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THE CONTRACTORSHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL.PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALLBE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAIDPLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCALJURISDICTION.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THECOMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BEPROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE ANDCLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORDDRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCAL JURISDICTION INSPECTOR AT ALLTIMES.13.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONALINFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.14.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OFCONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED INGOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITHHARD SURFACE OR LANDSCAPING.15.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCAL JURISDICTIONENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.16.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNINGOF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATEDEQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE LOCAL JURISDICTION.17.CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TO DIGGING.GENERAL NOTESRENTON1.ALL METHODS AND MATERIALS SPECIFICATION SHALL MEET ALL CITY OF RENTON STANDARDS.2.ALL RENTON STANDARD DETAIL DRAWINGS CAN BE FOUND AT THE FOLLOWING WEBSITE:https://edocs.rentonwa.gov/Documents/Browse.aspx?startid=13637033.ALL ASPHALT REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL - SECTION F110.0-110.2.4.ALL SIDEWALK REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL - SECTIONF 102.0.5.ALL CURB AND GUTTER REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL -SECTION F 103.0.6.UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON DOCUMENT RESEARCH AND FIELD EVALUATION. THEINFORMATION MAY NOT BE ACCURATE OR COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PHYSICALLY LOCATEAND VERIFY LOCATION AND DEPTH OF ALL UTILITIES WITHIN THE CONSTRUCTION PATH. ALL INSTALLATIONS MUST COMPLYWITH MINIMUM HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES.MFP20001274
KV15A NEW NODE WAKTVTH05300
19012 102ND AVE
RENTON, WA
JB# 198635REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSMDD2/13/207REVISIONSDATEDESCRIPTIONINITIAL4LEGENDTELECOMMUNICATIONSANITARY SEWERGAS LINEWATERSTORM DRAINRECYCLED WATERELECTRICALRAILROADRIGHT OF WAYDITCH LINECENTER LINEEDGE OF PAVEMENTFACE OF CURBPROPERTY LINELIP OF GUTTERGUARDRAILFENCESDSDWWSSSSGGEETTR/WLIPD/LEOPFOCRWRWTRENCHDIRECT BOREDBDBPROPOSED AERIAL STRAND AAPROPOSEDBASE LAYERSEXISTING UTILITIESEXISTING UTILITIES SYMBOLS POWER HANDHOLEPOWER MANHOLEPOWER CABINETSTREET LIGHT HANDHOLEPOWER SIDEWALK GUY SEWER CLEANOUTSTORM CATCH BASIN STORM MANHOLEWATER VALVEWATER METERTELECOM MANHOLETELECOM HANDHOLETELECOM CABINETTRAFFIC SIGNAL MANHOLETRAFFIC CABINETTRAFFIC SIGNAL PEDESTALPOWER VAULTSTREET LIGHT POLETRAFFIC SIGNAL VAULTTRAFFIC SIGNAL HANDHOLESIGN POSTPARKING METERCATV MANHOLECATV HANDHOLEPOWER PEDESTALGAS METERTEST VALVETRAFFIC LOOP DETECTORCATV PEDESTALBOLLARDWATER MANHOLETRAFFIC SIGNAL POLEPOWER GUYTRAFFIC DETECTORADA RAMPPEDESTAL(UNKNOWN UTILITY)MANHOLECULVERTFIRE HYDRANTGAS VALVE(UNKNOWN UTILITY)POWER ANCHORPOWER POLESEWER MANHOLETELECOM POLETELECOM PEDESTALPROPOSED VAULTPROPOSED ANCHORPROPOSED GUYPROPOSED MANHOLEPROPOSED SIDEWALK ANCHOR & GUYPROPOSED SYMBOLS ADA RAMP COMPLIANCEPEXISTING COMCAST VAULTEXISTING COMCAST SPLICEEXISTING COMCAST ANCHOREXISTING COMCAST GUYEXISTING COMCAST MANHOLEEXISTING COMCAST SIDEWALK ANCHOR & GUYP=VLP=GAS TEST POINTGAS MANHOLEPOWER UNKNOWN STORM CLEANOUTSTORM DRAIN VALVESTORM DRAIN UNKNOWN WATER UNKNOWNWATER WELLWATER PUMPWATER VAULTWATER RESERVOIRPPPPPP?PSLSLTSTSTSTSTSTSCCCTTTP=??TTSSSCSDD?DCDWWWWWVW?WELLPUMPGGGTLTLSDSEWER CATCH BASIN SSWATER SAMPLING STATIONOTHER UNKNOWNSTORM ACCESS POINTSEWER VALVESSEWER VAULT SSSEWER UNKNOWN S?SUB STATIONTRANSIT STOPSTORM DRAIN VAULT SDTREE PROPOSED RISEREXISTING COMCAST SYMBOLS POTHOLEBORE PITN/AN/ALEGEND PROOF/PULLEXISTING COMCAST PEDPEXISTING COMCAST POLE W/ NEW RISERFIRE HYDRANTFMHMHBUILDING OUTLINEFLFOG LINEMFP20001274
EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP EOP EOP EOP EOP EOP
R/WR/W
R/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/WR/W R/WR/WR/WR/W
R/WR/W
R/WR/W
R/WR/WR/WR/W
R/WR/W
R/WR/W
R/WSE 190TH STDRIVEWAYSIDEWALKPOLE 1102ND AVE SEPOLE 2POLE 3DRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYA A A A A A A A A A A A A A A A A A A213'156'
KV15A NEW NODE WAKTVTH05300
19012 102ND AVE
RENTON, WA
JB# 198635REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSMDD2/13/20Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.N7REVISIONSDATEDESCRIPTIONINITIAL5SITE PLAN EXISTING POLELEGANDOVERLASH 48CT FIBER TOEXISTING STRANDTIE INTO EXISTING SPLICECASE SP.WAKV.0798123123PLACE NODE AT POLE ONE4422PATH OF AERIAL OVERLASH
MFP20001274
EOPEOPEOPEOPEOPEOPEOP
EOPEOP
EOPEOPEOPEOPEOP
FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLR/WR/WR/WR/WR/W
R/W
R/WR/WR/WR/W
R/WR/WR/WR/WR/WR/WR/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/W
R/WSE 190TH STSE 192TH STSE 192TH STPOLE 4POLE 8POLE 5EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP EOPDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAY
CROSSOVERAAAAAAAAAAAAAAAAA A A A A A A 77'100'156'268'102ND AVE SEA
AAAAAPOLE 7POLE 6AAAAA170'105'
KV15A NEW NODE WAKTVTH05300
19012 102ND AVE
RENTON, WA
JB# 198635REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSMDD2/13/20Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.N7REVISIONSDATEDESCRIPTIONINITIAL6SITE PLAN EXISTING POLELEGANDOVERLASH 48CT FIBER TOEXISTING STRAND1212212PATH OF AERIAL OVERLASHPATH OF AERIAL OVERLASH22MFP20001274
EOPEOP EOP EOPEOPEOPEOP EOPEOPEOP
EOP
EOPEOPEOPEOPEOPFLFLFLFLFLFL FL
FL
FLFLFLFLFLFLFLFL FLFLFL FL FL
FL
FLFLFLFLFLFLFLFLFLFLFLFLR/WR/W R/W R/W R/W
R/W
R/WR/WR/WR/W
R/W
R/WR/WR/WR/WR/WSE 192TH STPOLE 9POLE 10EOPEOPEOPD
R
I
V
EW
A
YDRIVEWAYD
R
I
V
E
W
A
Y
D
R
I
V
E
W
A
Y
DRIVEWAYAAAAAAAAAAAAAAAAAAAAA256'99TH PL SEOPEOPEOPEOP DRIVEWAYDRIVEWAYDRIVEWAYSE 192TH STKV15A NEW NODE WAKTVTH05300
19012 102ND AVE
RENTON, WA
JB# 198635REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS:
COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSMDD2/13/20Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.N7REVISIONSDATEDESCRIPTIONINITIAL7SITE PLAN EXISTING POLELEGANDOVERLASH 48CT FIBER TOEXISTING STRAND122132PATH OF AERIAL OVERLASHTIE INTO EXISTING SPLICECASE # SP.WAKV.00163END OF ROW DESIGN44MFP20001274
SEFNCO COMMUNICATIONS
4610 TACOMA AVE
SUMNER WA, 98390
March 10, 2020
City of Renton
1055 South Grady Way
Renton, WA 98057
RE: Aerial Variance Request for JB#198635
To whom it may concern,
SEFNCO Communications has been contracted to design and engineer this project on behalf of Comcast
Cablevision. Comcast is applying for a variance request in order to upgrade their existing facilities.
Comcast proposes to overlash ~1226’ 48 ct fiber to 10 existing poles, place new aerial node at Pole #1,
place 200’ of aerial fiber storage near Pole #1 and upgrade existing coax equipment in the new node
boundary.
Comcast is requesting that the City of Renton approve this variance request based on the fact that the
requirements for undergrounding this proposed over-lash will not cause substantial adverse impacts to
other person or entities in the immediate area and will cause undue hardship.
1. Installation of undergrounding facilities will increase the total cost of construction roughly
15-25 times the amount of an aerial over-lash on the existing Comcast strand.
2. Potential damage to underground facilities will be increased.
3. Over-lash will not cause substantial adverse impact to other persons or entities in the
immediate area. Over-lashing the cable will be accomplished in a few days, and the
residents will not notice any impact. Comcast will clean up the over-lashed spans as
necessary and identify and remove any existing dead cables along this route.
4. The variance is necessary to prevent and undue hardship due to the increased construction
costs if forced to install the proposed extension underground.
5. The granting of the variance will not be materially detrimental to the public welfare because
Comcast does agree to underground the cable system, but they are waiving the obligation
into the future when all other utilities are underground to prevent an undue hardship
against Comcast currently.
Upon the granting of the Variance, Comcast will coordinate construction and traffic control as per your
requirements. Comcast and their contractors want to cooperate at the highest level and agree to
adhere to all provisions and requirements set forth by the City of Renton to insure safe installation and
maintenance of the proposed facilities.
MFP20001274
1501'
If you have any further questions regarding this project please contact Jamie Collins at 253 797-1936.
Thank you for your consideration in this matter.
Ashley Kiehn
Permit Area Manager
SEFNCO Communications, Inc.
o 253 999-2271 | e askiehn@sefnco.com
Attachments:
1. Application for ROW permit
2. 11” x 17” Site plan
3. 11” x 17” Design plan
4. Traffic Control Plan
April 9, 2020
Ashley Kiehn
SEFNCO Communications, INC.
4610 Tacoma Ave
Sumner, WA 98390
Via Email: AsKiehn@sefnco.com
SUBJECT: Request for Undergrounding Exemption (JB#198635, MFP20001274, 19210 99th Pl S)
Dear Ms. Kiehn:
The City of Renton has reviewed your request to grant Comcast an exemption from Renton Municipal
Code (RMC) 4-6-090(C) which states that all new electrical or communication facilities shall be required
to be installed underground, pursuant to the standards of the section of RMC.
Comcast proposes to have SEFNCO Communications, Inc. overlash approximately 1,501 lineal feet of new
48ct fiber to existing Puget Sound Energy (PSE) poles over two separate locations. The two overlash areas
on the existing poles are identified below:
1. Southeast of property 10056 SE 190th St continuing south 651 lineal feet on the west side of 102
Ave SE and ending at the pole to the northeast of property 19214 101st Pl SE.
2. Northeast of property 19208 102nd Ave SE continuing 850 lineal feet on the south side of SE 192nd
St and ending at the pole to the south of property 750 S 55th St.
ANALYSIS: The City has considered the request for an exemption from RMC 4-6-090. Ordinance 5720
grants Comcast, the right to install fiber optic cable and related appurtenances under, along, over, below,
through and across the streets, avenues and alleys of City of Renton within the right-of-way of Renton.
Section 3.4 of the franchise ordinance states that if all of the distribution lines all the wireline service
providers, such as telecommunications service providers, as defined in RCW 35.99.010, a utility service
provider or a Cable Operator (collectively “Service Providers”) in any portion of the Franchise Area are
underground, Grantee shall place its Cable System’s distribution cables underground within that area;
provided that such underground locations are actually capable of accommodating Grantee’s cable and
other equipment without technical degradation of the Cable Systems’ signal quality.
The proposal would utilize existing poles with other attached franchisee communication facilities and
overlash to the existing Comcast aerial path. As minimum vertical height clearance of 15’-6” would need
to be provided for, any existing obsolete cable will need to be removed; staff recommends these as
conditions of approval. Therefore, the City is granting an exemption with conditions, per the Comcast
franchise agreement which allows new overhead facilities to be placed overhead provided there are other
similar providers overhead as well.
Comcast Job JB#198635
Page 2 of 2
April 9, 2020
DECISION: The requested exemption from underground utility installation requirements (RMC4-6-090 (C)
as requested by the applicant is approved with conditions subject to the conditions below as the request
complies with the Comcast Franchise Agreement.
Conditions of Approval:
1. Any existing height violations within the Project Reach must be resolved at the time of
construction. New aerial lines within the Project Reach must have a minimum vertical
clearance of 15’-6”.
2. Any abandoned or unused lines within the Project Reach must be removed at the time that
construction is taking place.
3. A traffic control plan must be separately submitted to the City, and no construction may take
place until the City has approved a traffic control plan.
4. The new aerial fiber lines within the Project Reach must be converted to underground
facilities in the future, at Comcast’s cost, when any one of the following events occurs: (1) any
other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed
by a franchisee within the Project Reach, in which case Comcast shall participate in the joint
use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is
made available within the Project Reach that will accommodate the aerial lines. The new
aerial lines must be undergrounded within one year, or approved otherwise by the City of
Renton Community and Economic Development Administrator or designee, from the first
event triggering the requirement to underground the aerial lines.
This decision to approve the exemption with conditions is subject to a fourteen (14) day appeal period
from the date of this letter per RMC 4-8-110. Any appeals of the administrative decision must be filed
with the City Clerk, along with the required appeal fee, by 5:00 pm, April 23, 2020.
Sincerely,
Brianne Bannwarth, PE
Development Engineering Manager
cc: C.E. “Chip” Vincent, CED Administrator
Jennifer Henning, Planning Director
Justin Johnson, Assistant Development Engineering Manager
Scott Warlick, Engineering Specialist III
Holly Powers, Permit Technician
Franchise Permits
Cody Shackett, Comcast owen_shackett@comcast.com
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Conditions for Permit MFP20001274
Engineering
1 Engineering General Conditions
The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at
Comcast’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the
Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case
Comcast shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or
(3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial
lines must be undergrounded within one year, or approved otherwise by the City of Renton Community and
Economic Development Administrator or designee, from the first event triggering the requirement to underground
the aerial lines.
2 Engineering General Conditions
Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking
place.
3 Engineering General Conditions
Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial
lines within the Project Reach must have a minimum vertical clearance of 15’-6”.
4 Engineering General Conditions
A traffic control plan must be separately submitted to the City, and no construction may take place until the City
has approved a traffic control plan.
Page 1 of 1