Loading...
HomeMy WebLinkAboutMFP20001658.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP20001658 IVR Number: 20001658 Permit Information Permit Name: Seattle City Light Address/Location:04/16/2020Application Date:2144800488Parcel Number: 13045 RENTON AVE S Permit Type:04/16/2020Issue Date:Franchise Permit Work Class:04/16/2021Expiration Date:Major Utility Job Number: 2003028Franchise Type:Electric Description: Replace 2 poles in ROW (pole 137087 and 137099). Install New Pole between these poles. Replace wire from Pole 1370598 to Pole 1370991. Contacts Name Address PhoneTypeBilling Senait Telahun SEATTLE CITY LIGHT 700 5th Ave, Suite 3200, PO 34023 SEATTLE, WA 98124 B: (206) 615-0629ApplicantX CARMEN RODRIGUEZ-ORTON SEATTLE CITY LIGHT 700 5th Ave, Suite 3200, PO 34023 Seattle, WA 98124 Contact Mark Nagasawa SEATTLE CITY LIGHT 700 5th Ave, Suite 3200 Po Box 34023 (ms-S/7) Seattle, WA 98124 B: (206) 615-0667Contact POLYGON WLH LLC 11624 SE 5TH ST # 100 BELLEVUE , WA 98005 Owner General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES 20001658Justin JohnsonScott Warlick4/16/20204/16/2020 P79 P 7 8 P 1 9 5 P1 6 3 S 132ND ST 84TH AV SNW 2ND ST L50’A B C UTILITYWORKAHEADRIGH T LANE END S S.C.L TRAFFIC CONTROL WO # 2003028 Date: 4/09/2020 Location: 13045 RENTON AV S Project Engineer: N. BROUGHTON TCP: njmr RENTON-A START DATE: PENDING FLAGGER (IF APPLICABLE) LEGEND CHANNELIZING DEVICES WORK VEHICLE F SIGN LOCATION LOCATION WORK AREA OR SEQUENTIAL ARROW PANEL HIGH LEVEL WARNING DEVICE Table X-l CLASS OF ROAD WARNING SIGN SPACING TAPER LENGTH (L) CHANNELIZING DEVICE SPACING IN FEET (maximum) WARNING SIGN IN FEET IN FEET VEHICLE BARRICADES & DRUMS OTHER** IN INCHES MIN. SIZE LANE WIDTH Taper (S) Tangent Taper (S) Tangent A B C I *75 90 Speed limit Speed limit X 2 15 30 30 X 30 II 150 150 75 150 200 Speed limit Speed limit X 2 20 50 30 X 30 III 300 300 150 400 500 Speed limit Speed limit X 2 30 80 48 X 48 10’ 12’ ROAD CLASS DEFINITIONS CLASS I - Central Business, University District CLASS II - Arterial Streets, CLASS III - All partially or full controlled access arterial streets *Advanced warning signs if feasible ** Vertical barricades, cones, tubular guideposts REN T ON AV S R9-9R9-911’m in11’m in 1 1’m in RIGHT LANE CLOSURE TCP APPROACH WORKING ONE LOCATION AT A TIME RIGHT LANE CLOSURE TCP APPROACH WORKING ONE LOCATION AT A TIME SPEED LIMIT35 Adjust sign spacing per MUTCD and site conditions. NOTE: POLE IS LOCATED NEXT TO DRIVEWAY Adjust sign spacing per MUTCD and site conditions. NOTE: POLE IS LOCATED NEXT TO DRIVEWAY Adjust sign spacing per MUTCD and site conditions.L50’ABCUTILITYWORKAHEADONE LANEROADAHEADUTILITYWORKAHEADABCONELANEROADAHEADVARIESFF 11’ min NOTE: SCL TO ASSIST LOCAL TRAFFIC. ~SCL WILL FACILITATE PEDESTRIAN ACCESS PAST WORK AREA ON EXISTING SIDEWALK. ~SCL SHALL NOT ROUTE PEDS WITHIN 2’ OF CURB/TRAVEL LANE EDGE. ~SCL SHALL STOP WORK AS REQUIRED FOR PEDS TO PASS WORK AREA SAFELY. Adjust sign spacing per MUTCD and site conditions. BRIEF JOB NOTES: P195: NES RENTON AVE S 2N S 132ND ST ~REPLACE POLE ~TRANSFER EQUIPMENT ~MAKE CONNECTION P163: NES RENTON AVE S 1N S 132ND ST ~SET POLE AS STAKED ~MAKE CONNECTION P78: NE SIDE RENTON AV S, 1S S 132ND ST ~PICK UP EXISTING WIRE P79: SS S 132ND ST, 2E 84TH AVE S ~REPLACE WIRES PERMIT #________S.C.L. TRAFFIC CONTROL PLAN 1.) 4-5 LANE TWO WAY - RIGHT LANE CLOSURE WORK ON THE EAST SIDE OF RENTON AV S NEAR S 132ND ST ONE LOCATION AT A TIME. 2.) 2 WY NON ARTERIAL (ONE LANE TWO WAY OPERATION) WORK ON THE SOUTH SIDE OF NW 2ND ST NOTE: REFER TO TABLE X-1 FOR TYPICAL DIMENSIONS OF “A , B. C & L”. NOTE: NOTIFY METRO AND SCHOOLS 10 DAYS IN ADVANCE Flaggers shall conform W/ WAC: 296.155.305 and 468.95.302 N NTS 326NE/327NW R EN T ON A V S MFP20001658 MFP20001658 SCL WO 2003028 MFP20001658 SCL WO 2003028 MFP20001658 SCL WO 2003028MFP20001658 SCL WO 2003028 MFP20001658