HomeMy WebLinkAboutMFP20001658.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Major Franchise Permit: MFP20001658
IVR Number: 20001658
Permit Information
Permit Name: Seattle City Light
Address/Location:04/16/2020Application Date:2144800488Parcel Number: 13045 RENTON AVE S
Permit Type:04/16/2020Issue Date:Franchise
Permit Work Class:04/16/2021Expiration Date:Major Utility
Job Number: 2003028Franchise Type:Electric
Description: Replace 2 poles in ROW (pole 137087 and 137099). Install New Pole between these poles. Replace wire from Pole
1370598 to Pole 1370991.
Contacts
Name Address PhoneTypeBilling
Senait Telahun
SEATTLE CITY LIGHT
700 5th Ave, Suite 3200, PO 34023
SEATTLE, WA 98124
B: (206) 615-0629ApplicantX
CARMEN RODRIGUEZ-ORTON
SEATTLE CITY LIGHT
700 5th Ave, Suite 3200, PO 34023
Seattle, WA 98124
Contact
Mark Nagasawa
SEATTLE CITY LIGHT
700 5th Ave, Suite 3200 Po Box
34023 (ms-S/7)
Seattle, WA 98124
B: (206) 615-0667Contact
POLYGON WLH LLC 11624 SE 5TH ST # 100
BELLEVUE , WA 98005
Owner
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
20001658Justin JohnsonScott Warlick4/16/20204/16/2020
P79
P
7
8
P
1
9
5
P1
6
3
S 132ND ST 84TH AV SNW 2ND ST
L50’A
B
C UTILITYWORKAHEADRIGH
T
LANE
END
S
S.C.L TRAFFIC CONTROL
WO # 2003028 Date: 4/09/2020
Location: 13045 RENTON AV S
Project Engineer: N. BROUGHTON
TCP: njmr
RENTON-A
START DATE: PENDING
FLAGGER (IF APPLICABLE)
LEGEND
CHANNELIZING DEVICES
WORK VEHICLE
F
SIGN LOCATION LOCATION
WORK AREA
OR
SEQUENTIAL ARROW PANEL
HIGH LEVEL WARNING DEVICE
Table X-l
CLASS OF ROAD WARNING SIGN SPACING TAPER LENGTH (L) CHANNELIZING DEVICE SPACING IN FEET (maximum) WARNING SIGN IN FEET IN FEET
VEHICLE BARRICADES & DRUMS OTHER** IN INCHES
MIN. SIZE
LANE WIDTH Taper (S) Tangent Taper (S) Tangent A B C
I *75 90 Speed limit Speed limit X 2 15 30 30 X 30
II 150 150 75 150 200 Speed limit Speed limit X 2 20 50 30 X 30
III 300 300 150 400 500 Speed limit Speed limit X 2 30 80 48 X 48
10’ 12’
ROAD CLASS DEFINITIONS
CLASS I - Central Business, University District
CLASS II - Arterial Streets,
CLASS III - All partially or full controlled access arterial streets
*Advanced warning signs if feasible
** Vertical barricades, cones, tubular guideposts
REN
T
ON
AV
S
R9-9R9-911’m
in11’m
in
1
1’m
in
RIGHT LANE CLOSURE
TCP APPROACH
WORKING ONE
LOCATION AT A TIME
RIGHT LANE CLOSURE
TCP APPROACH
WORKING ONE
LOCATION AT A TIME
SPEED
LIMIT35
Adjust sign spacing per
MUTCD and site conditions.
NOTE:
POLE IS LOCATED
NEXT TO DRIVEWAY
Adjust sign spacing per
MUTCD and site conditions.
NOTE:
POLE IS LOCATED
NEXT TO DRIVEWAY
Adjust sign spacing per
MUTCD and site conditions.L50’ABCUTILITYWORKAHEADONE LANEROADAHEADUTILITYWORKAHEADABCONELANEROADAHEADVARIESFF
11’ min
NOTE: SCL TO ASSIST LOCAL TRAFFIC.
~SCL WILL FACILITATE PEDESTRIAN ACCESS
PAST WORK AREA ON EXISTING SIDEWALK.
~SCL SHALL NOT ROUTE PEDS WITHIN 2’ OF
CURB/TRAVEL LANE EDGE.
~SCL SHALL STOP WORK AS REQUIRED FOR
PEDS TO PASS WORK AREA SAFELY.
Adjust sign spacing per
MUTCD and site conditions.
BRIEF JOB NOTES:
P195: NES RENTON AVE S 2N S 132ND ST
~REPLACE POLE
~TRANSFER EQUIPMENT
~MAKE CONNECTION
P163: NES RENTON AVE S 1N S 132ND ST
~SET POLE AS STAKED
~MAKE CONNECTION
P78: NE SIDE RENTON AV S, 1S S 132ND ST
~PICK UP EXISTING WIRE
P79: SS S 132ND ST, 2E 84TH AVE S
~REPLACE WIRES
PERMIT #________S.C.L. TRAFFIC CONTROL PLAN
1.) 4-5 LANE TWO WAY - RIGHT LANE CLOSURE
WORK ON THE EAST SIDE OF RENTON AV S NEAR S 132ND ST ONE LOCATION AT A TIME.
2.) 2 WY NON ARTERIAL (ONE LANE TWO WAY OPERATION)
WORK ON THE SOUTH SIDE OF NW 2ND ST
NOTE: REFER TO TABLE X-1 FOR TYPICAL DIMENSIONS OF “A , B. C & L”.
NOTE: NOTIFY METRO AND SCHOOLS 10 DAYS IN ADVANCE
Flaggers shall conform W/ WAC: 296.155.305 and 468.95.302 N
NTS
326NE/327NW
R
EN
T
ON
A
V
S
MFP20001658
MFP20001658
SCL WO 2003028
MFP20001658
SCL WO 2003028
MFP20001658
SCL WO 2003028MFP20001658
SCL WO 2003028
MFP20001658