HomeMy WebLinkAboutCOPY-APPROVED-WATER PLANS W-4015.pdfLOT 3 DRAINAGE NOTE:
LOT 3 ROOF DRAINAGE TO BE SPLIT
EQUALLY BETWEEN INFILTRATION TRENCH
AND DRYWELL.
PRIVATE 7 LF
8" DI ® 0.6%
9391 042305-9392
042305-9393
PRIVATE CB16, TYPE 1
STA:13+30.56, 5.22' RT
PROPOSED RIM=438.(S7t
PERMEABLE IE=435.35, 8" ,E)
DRIVEWAY SEWER STUB
659 S.F. 6" IE=435.30
L-� 15 LF 6" PVC
® 2.00% MIN,
436
c
_ a
4+L45 14+00 - -
PRIVATE 38 LF d°
8" DI ® 0.5% °
o O
0
0 10' PRIVATE STO M
00 DRAINAGE EASEME °
O EMERGENCY
N i, OVERFLOW H
oLOT 3 CLEANOUT PER DI
o 8,817 SFC.O.R. STD. PLAN
N �n ` FF=437.0 226.0 ON SHEET O
X 7 (NIP)
LO EMERGENCY PRIVATE 5 LF 8"
OVERFLOW DI ® 50.0%
8" IE=435.00 PRIVATE 32 LF
307 I " 10' PRIVATE BSTOR ® 0.5%
PRIVATE 8 LF 8
DRAINAGE EASEMENT
DI ®5.88% - - - - -
+ -_j
5
436
PRIVATE CB14, TYPE 1 - -
RIM=436.00 777
PRIVATE 94 LF
IE=434.53, 8" (N,W,E) 8" DI ®0.5%
PRIVATE 5 LF 8"
DI ® 0.6%
RIPRAP PAD
8x7'x1' 042305TR-A
IE=434.50
SEE DETAIL SHEET 9
445
440
435
430
3
0
425
I
420
14+45
042305-9394
END CEMENT CONC. CURB
STA:13+25.58, 6, 00' RT
PRIVATE CB17, TYPE 1
STA:13+23+53, 5.22' RT
RIM=438.81
=N88*1
" (W)
9'30"W 405.66'
042305-9395
16'
S88'19'30"E 95.27'
2
NE 114 OF SE 114 OF SEC. 4, TWP. 23 N., RNG. 5 E. W.M.
CITY OF RENTON, STATE OF WASHINGTON
20'...
-1440.68
440
STA:13+12.83, 1.0' RTI 173 LF 8" J J +
RIM=439.20 CLASS 53 DI WM L2
IE=434.67, 8" (E) 1" WATER SERVICE 441.20
IE=434.84, 6" (W) FOR LOT 2 PER
C.O.R. STD. PLAN SEWER STUB
CEMENT CONC.
CURB (TYP)
285.50'
RETAINED TREE NOTE:
ARBORIST IS TO BE PRESENT ON SITE
DURING CONSTRUCTION OF THE SHARED
EXIST. SSMHCB T-1RIM=445.59'
RIM=445.86CENTER OF 8" CONC.
IE (N.) 12" CMP-440.66'CHANNEL (N. & S.)=432.19'IE (S.) 12" CMP=440.66'
DRIVEWAY, ASSOCIATED UTILITIES & THE END SIDEWALK TO
PUBLIC STREET FRONTAGE. AVOID GRADING ON
ADJACENT PROPERTY
042305-9267 BEGIN CEMENT CONC. CURB
STA:10+39.08, 6.00' RT
CLEANOUT AND 2x2x1'
CONCRETE PAD PER PRIVATE CB#3, TYPE 1 PRIVATE CB#2, TYPE 1L
C.O.R. STD. PLAN 403.1 STA:11+15.43, 5.22' RT W/SOLID LID
ON SHEET 8 (TYP) RIM_441.19STA:10+44.22, 5.22' RT
HP 4441.45 IE--Z8.36, 12" (E) RIM=442.60
IE=437.26, 12" (SW)
L*
JCE
441.95
C.O.R. STD. PLAN LOT 2 18 LF 6" PVC 442.01
320.1 TIP ® 2.00% MIN.442.01
_00 ( ) /� 7,789 SFPER C.O.R. STDIt O� FF=440.0PLAN 406.1 (TYP) 20cnPRIVATE CB#5A, TYPE 1
RIM=439.Of
IE=435.16, 8" (N,W,E)
EMERGENCY
OVERFLOW
8" IE=438.00
'vV �
PRIVATE 11 LF 8"
DI ® 28.3%
PRIVATE CBI TYPE 1
RIM=437.7E
IE=435.00, 8" (N,W,E)
042305-9422
SOIL AMENDMENT NOTE:
ALL AREA OUTSIDE OF BUILDING
FOOTPRINT TO HAVE AMENDED SOIL
PER C.O.R. STD PLAN 264 ON SHEET
8, SEE APPENDIX C2.13 OF THE 2017
CITY OF RENTON SURFACE WATER
DESIGN MANUAL FOR SOIL AMENDMENT
DESIGN GUIDELINES.
042305-9421
441.90
S88'1.9'30"E
313 LF:�r- PVC 0 1.0% PRIVATE 6f
441..65 ;:• 11+00
170. LF 8" CLASS 53 DI WM
TLC T - aT
_ 441.92 SEW R STU
FIRE HYDRANT ASSEMBLY - - - -STA: 10+6 °
6" 1 =435. Ik 2
PER C.O.R. STD. PLAN 310.1 10' WATER "
STA:11 +50.02, 17.92' LT EASEMENT ® 1 .1% VC
8 x6 TAPPING TEE (MJxFL) PROPOSED a
6" TAPPING VALVE (FLxMJ) PERMEABLE
W/THRUST BLOCKING DRIVEWAY
LOT 11,002 S.F. a°
8,051 SF ° O mn
10.00' 10.00,
a ° ° 1 " WATER SERVICE FF=442<0
.442.09.a 442.09 FOR LOT 1 PER d
° o 441.99 C.O.R. STD. PLAN EMERGENCY a d
o -co
320.1 (TYP) OVERFLOW
° N o 8" IE=440.00 „
CD
co
PROPOSED S88'19'30"E 405.76' S
PERMEABLE J
DRIVEWAY
697 S.F.
042305-9420
042305-9419
- r
PRIVATE 6 LF 8" CCP ® 5.0�
10' LANDSCAPE &
PRIVATE DRAINAGE -
EASEMENT
PRIVATE CB# 1, TYPE 1 L
W/SOLID LID &
INSIDE DROP STRUCTURE
STA:10+43.56, 57.75' LT
RIM=442.Of
042305-9077 IE=436.25, 12" (N,SE)
IE=439.70, 8" (W)
PRIVATE 26 LF 12"
CCP ® 1.5%
0 5 10 20
0
TRANSITION TO KEYNOTES: SCALE 1 " = 20'
EXISTING SIDEWALK
O CONTRACTOR TO POTHOLE EXISTING UTILITIES PRIOR TO CONSTRUCTION
Ic CEMENT CONIC. CURB
STA © EXISTING j- WATER SERVICE AND METER TO BE ABANDONED AT MAIN
CFSET 1010. 00' RT LINE (BY CITY) UNLESS IT IS RE -USED FOR IRRIGATION A DCVA IS
I REQUIRED AND SHOULD BE LOCATED ON PRIVATE PROPERTY
C01�5TRUCT CONCRETE DOWNSTREAM OF THE WATER METER.
DRIVEWAY PER C.O.R.
STD.' PLAN 104.2 © CUT AND CAP EXISTING J" SERVICE AT MAIN LINE (BY CITY).
i SSMHj1
�°On STA:10+00.01, 1.00' RT OD INFILTRATION TRENCH SYSTEM TO BE CONSTRUCTED UNDER SINGLE
00 RIM=443.38 FAMILY BUILDING PERMIT PER DETAIL SHEET 6 ALL IMPERVIOUS TO BE
a IE=431.69, 8" (N,S) ROUTED TO TRENCH (TYP).
CENTER OF CHANNEL
30. IE=431.54, 8" (W) QE AREA DRAIN TO FG PROVIDE DOWN TURNED ELBOW IN PAVED AREAS.
/ CONNECT TO O PROPOSED MAILBOX LOCATION.
° o - - - - I EX. 12" DI WATERMAIN
IN ACCORDANCE WITH CITY © OF RENTON REQUIREMENTS EXISTING MAILBOXES TO BE RELOCATED, COORDINATE WITH POSTMASTER
' A STA:9+80.06, 9.00' LT O 10'0 x 5' DEEP INFILTRATION DRYWELL PER DETAIL ON SHEET 9. DO NOT
12 x8" TAPPING TEE (MJxFL) CONNECT FOOTING DRAINS.
8" TAPPING VALVE (FLxMJ)
OOK�A - W/THRUST BLOCKING Oj CONTRACTOR TO POTHOLE AND VERIFY ELEVATION OF EXISTING 36" SPU
PER C.O.R. STD. PLAN 300.1 WATER LINE PRIOR TO INSTALLATION OF NEW 8" SEWER MAIN.
N_ o CONTRACTOR TO SUPPORT EXISTING PIPE PER PIPE SUPPORT PLAN ON
o o y \ SHEET 10. CALL KATHI ILLMAN OF SPU (206) 684-3933 PRIOR TO ANY
00 WORK NEAR WATERLINE INCLUDING POTHOLING. oyA SAWCUT EXISTING PAVEMENT FOR
WATER AND SEWER CONNECTIONS
•
�o O 6" THICK 4'X4' ETHAFOAM PAD TO BE PLACED BETWEEN SPU WATER
�d d w \ = AND RESTORE PAVEMENT AND
oo
oFOGLINE PER C.O.R.STANDARDS z ° MAIN AND PROPOSED 8" WATER LINE, CENTERED ON CROSSING.
o 00
n a
O z/� �,o0n ��L oy a OK AREA OF TRENCH WITH LESS THAN 3' OF COVER TO BE BACKFILLED
`.J A WITH CDF.
N z
'0 w" 1 .,d W W -- W W 1
CB T-2
co RIM-440.97'
44 G° 3 18" CMP=435.37'
IE (N.) 12" CMP=435.87'
0
C4 NEW 12" IE=435.87
a CORE DRILL OPENING &
° N PROVIDE WATER TIGHT SEAL
20' PRIVATE ACCESS / UTILITY EASEMENT
CB T-1 16' ACCESS
1 a RIM=441.03' z -
IE (N.) 12" CMP=437.48' 6 z
s Uj IE (S.) 12" CMP=437.48'
a TCURB &
O MATCH XIS�NG o E (E.) 6" PVC=438.03' Q
O � u
Q END CEMENT CONIC. CURB, i
o MATCH EXISTING o STA 10+21.89 \��
SIDEWALK & OFFSET 70.15'LT
s RESTORE PLANTER
a
SUBGRADE POROUS ASPHALT OR
CEMENT CONCRETE PERVIOUS CONCRETE
s a CURB PER C.O.R. STD. PLAN 101 PER C.O.R. STD. PLAN 261.10
1 0 3 0
EXIST. SSMH SHARED DRIVEWAYACCESS SECTION
( RIM=439.90' N.T.S.
CENTER OF 8" CONC. CHANNEL a
N S & W -430 75'
AREA TO BE RIM=440.97 (., )-
FILLED W/CDF IE(S) 18 "CMP= 435.3 7 40' R/W
PRIVATE CBI TYPE 1L IE(N)12"CMP=435.87
W/SOLID LID NEW 12" 10
STA:10+44,22, 5.22' RT o f o f IE=435.87 z DEDICATION 8'
22'
RIM=442.60 F= � CORE DRILL UEXISTING
Q OPENING & > PLANTER
IE=437.26, 12" (S,W) 3' ¢ 1' �� 8' PAVEMENT
LVC=30.00LVC=30.00 W M I PROVIDE WATER Z I SIDEWALK 0. 5'
PVI:11 +45.84 EL:441.54 EL:441.1�PRIVATE 63 LF o TIGHT SEAL 10 SAWCUT EXIST. PAVEMENT
12" CPP ® 1.6% o I CONNECT TO EX. 12" DI 1.5%ATCH EXIST. SECTION ON
FP-V/:11+10.43
�0 UNION AVE NE
W
+
N
+;: t d
- LX. 36 wM
-�
U
W
z
. GRADE AT C/L
�I .- �
o
J
I
PRIVATE CB16, T1PE 1 a
8" CA
W/ 2" B.O.
TRACT A ACCESS
�
m w �
�"
m
TA:13+30.56, 5. 2 RT ac w
ASSEMBLY
AND THRUST
-
.00%
W
RIM= 8.7E o
BLOC
NG
IE=435.35, 8 (SE) a W
1.009
PROPOSED
GRADE AT
3' MIN
PRIVATE 69 L
12" DI ® 1.6%
a
173 LF
8* CLASS 53
C/L TRACT
A ACCESS
BE'
1 WATERMAIN
O
) CLEARANCE
�
17
LF 8"
6
?
cv
CLASS53
DI
® 1. D1
SEWER STUB
WA T
FRMAIN
6" IE=435.30
p
5 LF 6" PVC
PRIVATE 313 LF
8 PVC 0 1.0.
2.00% MIN.
SEWER STUB
PRIVATE
CB 3, TYPE
1
SEWER
STUB
SSMH12
STA: 12+ 15
IRE HYDRANT ASS
ST
RT
STA:
10+65
:11 + 15.43, 4.5'
PRIVATE
7 LF
STA:13+1
.45, 3.34' LT
6" IE=433.69
PER
C.O.R. STD. PLAN
310.1
RIM=441.19
6" IE=
32.19
8" DI ® 0.6%
RIM=STA:
IE=434.6
8" (E)
"
11 +50.02, 17.
"
2' LT
IE=438.36, 8"
E)
SSMH Il
PRIVATE C 7, TYPE 1
IE=434.8
,
6" (W)
8 x
6"
TAPPING TEE
TAPPING VALVE
JxFL)
MJ)
PRI
W
1
ATE CB TYPE
1 L
STA:9+99.64 3.
'
OLID LID &
STA:13+23+ , 5.22 RT
W/THRUST BLOCKING
INS
DE DROP STRUC
RE
RIM=443.38
RIM=438.81
ST
:10+43.56, 57.75
LT
IE=431.69, 8"
IE=43 .39, 8- (W)
RIM
=442.0#
CENTER OF CHA
IE=
36.25 12" N S
IE=431.54, 8"
IE39.70,
" ()
o
cc o
rn ��
o �00
O
M
00
M
O
N
O
m d
O)
c
el d
'6
Cc�
cAci
WC9
W9
W
� W
W
W
9 W
�
w
Cww
W
9
w
.�
C
C9 (-D
C9 C�
w
w
L
W
w
w
�uo
14+00
Lncompass
ENGINEERING & SURVEYING
Western Washington Division
165 NE Juniper Street, Suite 201 • IssaQuah, WA 98027 • Phone: (425) 392-0250 • Fax: (425) 391-3055
Eastern Washington Division
407Swiftwater Blvd. • Cle Elum, WA 98922 • Phone: (509) 674-7433 • Fax: (509) 674-7419
13+00
8105119
12+00
TRACT A ACCESS
HORIZ. 1 "=20'
VERT. 1 "=5'
7
REVISED PER
SPU
COMMENTS
6
ADDED SPU PIPE
SUPPORT PLAN
5
REVISED PER
CITY
COMMENTS
DATED
4111/19
4
REVISED PER
CITY
COMMENTS
DATED
3122119
3
REVISED PER
CITY COMMENTS
DATED
2/1/19
2
REVISED PER
CITY
COMMENTS
DATED
8110118
1
REVISED PER
CITY
COMMENTS
DATED
7130118
NO.
REVISION
NEM
8105119
NEM
NEM
6110119
NEM
NEM
6/7/19
NEM
SURVEYED:
NEM
3/27/19
NEM
DESIGNED:
NEM
3/6/19
NEM
NEM
12119111
NEM
°R4W"
NEM
91211181
NEM
CHECKED:
BY I DATE I APPR I APPROVED
11+00
445 WATERMAIN IN ACCORDANCE 2%
WITH CITY OF RENTON gum
REQUIREMENTS
STA:9+80.06, 9.00' LT
12"x8" TAPPING TEE (MJxFL) 6" HMA CLASS
8" TAPPING VALVE (FLxMJ) CEMENT CONCRETE 1/2" 64-22
W/THRUST BLOCKING SIDEWALK PER 6" CRUSHED SURFACING
440 PER C.O.R. STD. PLAN 300.1 C.O.R. STD. PLAN TOP COURSE
102 ADDITIONAL STRUCTURAL FILL MAY BE
435
arty:
4 LT
,S
NEL
W
425
rn
rn
N
420
10+00 9+80
REQUIRED DEPENDING ON SOIL CONDITIONS
CEMENT CONCRETE
CURB PER C. 0. R.
STD. PLAN 101
(2) STREET TREES
REQUIRED
TYPICAL SECTION UNION AVE. NE
S-401501
W- 4 015 01
R - 4- 015 05
W
IN COMPLIANCE WITH CITY OF RENTON STANDARDS Q
SCALE:
SDM 1 " = 20' HORI ORNTAL: NAD 1963/1997 HU YNH SHORT PLAT
NEM [;Rl o CITY OF
L UA 17- 000855
RENTON
LFM
ONE INCH DATU M
NEM IFAT FULL NOTONEINCH Planning/Building/Public Works Deft. GRADING / UTILITY / DRAINAGE
CJA SCALE ACCORDINGLY PLAN CX. P R O FI L E
O
I
DATE:
8105119
FIELDROOK: N/A
PAGE., NIA
DRAWING NO:
17597
SHEET., 5 OF., 10