Loading...
HomeMy WebLinkAboutR-411113W v V NZ ti N. A. ©0.0000 / f � I I I , 14' 47x5' DEEP -I INF/L TRA TION DRY I WELL PER F/GU' �f I C. 2.2. C RIGHT NI A 0 I o I � � II II I, I, I, I, i I I , I, II ❑ I, I, I, U SEE PROF/LE VIEW, EET CB 4 1.5' W/DE FOOTING NDS DURASL Off TRENCH DRAIN SCALE: 1" = 10' 0 5 10 20 INFIL TRA T/ON DRY WELL - PLAN VIEW Vr'„r'",T PA F/L TER FABRIC — MI, OR APPROVED EOUA AND SIDES TOP 2 ELEV. 36 WASHED DRAIN ROCK 1 1/2" 3" (TYR) DRY WELL — PROF/LE VIEW. 1"10' DRYWELL BLDG SETBACK MIN 5' SETBACK REQUIRED PER 2016 KCSWOM SECTIONS C2.2.2 AND C2.2.3 AS BLDG /S SLAB ON GRADE. UNDISTURBED EARTH (TYR) NW7' NA. FINISH SURFACE RIM 371.93 U . TYPE 2-48"0 CB CB 4 8" SOLID PVC PIPE 0 5--0 J ELEV. 363.50 N.A. 8" If 367 368.69 (TYPE INFIL TRA T/ON DRY WELL - PROF/LE VIEW 1 "=2' Q t 12 IF 968.. 367. 91 OVERFLOW P/PE 8" IF 966 368.69 ROOF DRAIN REVISION ASBUIL T NOTF- ALL INFRASTRUCTURE APPURTENANCES ASBUIL T ARE INDICATED WITH DESIGN INFORMATION LINED OUT AND ADJACENT ASBUILT INFORMATION ADDED. ITEMS NOTED AS 'lVA. " WERE NOT ASBUIL T. SURVEYED: ROBERT WEST DESIGNED: GINA BROOKS DRAWN: DA VID VAUGHN CHECKED: GINA BROOKS BY DATE APPR APPROVED: GINA BROOKS SCALE: 1 "=10' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY C.2.2 FULL INFILTRATION FIGURE C.2.2.0 SCHEMATIC REPRESENTATION OF A TYPICAL DRYWELL INFILTRATION SYSTEM ROOF DOWNSPOUT HOUSE ROOF FLOW DOWNSPOUT ROOF DOWNSPOUT OVERFLOW HOUSE SPLASH BLOCK FLOW F MIN. SETBACK FROM BUILDING FINE MESH SCREEN CATCH BASIN (YARD DRAIN) O ! 6tE FILLED WITH \1 2" - 3" WASHED DRAIN ROCK / MARK CENTER OF HOLE WITH 1" CAPPED PVC OR OTHER MEANS FLUSH WITH SURFACE TOPSOIL MIN. 4" DIA. PVC PIPE CATCH BASIN—J SIDES OF HOLE (YARD DRAIN) LINED WITH FILTER FABRIC 15' MIN. AS REQUIRED, SEE SECTION C.2.2.3 2017 City of Renton Surface Water Design Manual CONSTRUCTION RECORD DRA WINGS THIS CONSTRUCTION RECORD DRAWING /S A COPY OF THE APPROVED CONSTRUCTION DRAWINGS PREPARED BY CORE DESIGN, INC. AND HAS BEEN EDITED TO REFLECT ASSUIL T CONDITIONS. THE INFORMATION PROVIDED ON THESE RECORD DRAWINGS /S A COMB/NATION OF FIELD SURVEY INFORMATION AND DOCUMENTED FIELD REVISIONS. VERTICAL NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M C-51 SEE PLAN FOR DIMENSIONS 1' MIN. SEE PLAN FOR DIMENSIONS SEE PLAN FOR DEPTH VARIES HA�EFILLED WITH 1 2' - 3" WASHED DRAIN ROCK MIN. 1' ABOVE SEASONAL HIGH GROUNDWATER TABLE, SEE SECTION C.2.2.2 12/12/2016 CIVIL ENGINEERING CO zit LANDSCAPE ARCHITECTURE W PLANNING DESIGN SURVEYING W CORE ✓OB NO 18227 V 12100 NE 195th St, Suite 300 Bothell, Washington 98017 425.885.7877 2/3/23 (DESIGN ONL`I') Q IN COMPLIANCE WITH CITY OF RENTON STANDARDS R-411113 CITY OF RENTON Planning/Building/Public Works Dept. Q v W v DATE: k KIDDIE RESEARCH DA YCARE CENTER MAR. 2020 3123 NE SUNSET BL VD FlELDBooK: \ RENTON, WA 98056 PAGE: O DRAWING NO: C4.33 INFIL TRA T/ON DRY WELL DETAILS SHEEP: 13 OR 21