Loading...
HomeMy WebLinkAboutT-411101ILLUMINATION WIRING SCHEDULE RACEWAY CONDUIT SIZE I L�8 EQUIP. GROUND T WIRER NO. EX. NEW EX. NEW 1 2" SCH40 PVC 2 1 2 EXISTING ** 2 1 3 2 SCH40 PVC 2 1 2" SCH40 PVC SPARE 1 * EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER THAN THE LARGEST WIRE SIZE IN THE CONDUIT. * * OTHER EXISTING CONDUIT/CONDUCTORS MAY BE PRESENT. NG\NEER\N \S CpN R�P �O 80 SUR pC� w p SR O l�Nw�VOCp�pN �F.� pN\'�•�R 2p'L�•ICS�Nw g`l NpR�\A �\S P NS % pC?irjaEO vas E PQQ jCPB �$-'ao � 0 � pNS ONRp �08ER 3N PSpRN'p�ON ESE RE OAS\G QR �0� pKU�GN \NF OpES Np� p�N � p�NORS. _ PGA o pR CeR �0�0 252+00 ILLUMINATION POLE SCHEDULE LUM. STREET POLE ID GPS MOUNT. ARM WATTAGE/ ROADWAY PEDESTRIAN BASE SERVICE/ POLE NAME NO. * COORD- STATION OFFSET HEIGHT LENGTH TYPE FIXTURE MODEL FIXTURE MODEL TYPE CIRCUIT COMMENT N0. INATES** \� Oi NE 12TH ST 253+56.0 28.0' LT 35 14' 8' 4' 80 39 LED DMSSX DOMUS DOMUS FIXED ILLUM B -80W-T-LE3F DOS-30W-T-LE3F NE 12TH ST 253+00.5 28.0' LT 14' 4' 30 LED - DOS-30W DOMUS LE3F FIXED ILLUM B O3 NE 12TH ST 254+09.0 28.0' LT 14' 4' 30 LED - DOMUS FIXED ILLUM B DOS-30W-T-LE3F * POLE ID NUMBERING SHALL BE PROVIDED BY CITY AT TIME OF CONSTRUCTION AND INSTALLED BY CONTRACTOR. 2 �GPS COORDINATES INFORMATION WILL BE ADDED BY CONTRACTOR ON AS -BUILT PLANS. A x `V 41 ILLUMINATION CONSTRUCTION NOTES CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD DETAIL 117.1 AND 117.2. FURNISH AND INSTALL NEW POLE AND LUMINAIRE PER ILLUMINATION POLE SCHEDULE, THIS SHEET, AND CITY OF RENTON STANDARD DETAILS 1 17.1, 1 17.2, 119, 120, AND 121. EXISTING STREET LIGHT POLE TO REMAIN. PROTECT DURING CONSTRUCTION. OINTERCEPT ILLUMINATION CONDUCTORS IN EXISTING JUNCTION BOX. SPICE EXISTING CONDUCTORS TO NEW CONDUCTORS IN EXISTING JUNCTION BOX. / / O REMOVE EXISTING LUMINAIRE AND FOUNDATION TO A MINIMUM OF 24" BELOW GRADE. FILL AND COMPACT VOID. Ax EXISTING TYPE III MAST ARM POLE TO REMAIN. PROTECT DURING CONSTRUCTION. / O6 EXISTING CONTROLLER AND SERVICE CABINETS TO REMAIN. PROTECT DURING CONSTRUCTION. -------------------------------------------------------- NE 12TH STREET SD — SD— _ cn N88.54'30"W (BASIS OF BEARINGS) 2723.19 EX R W REVISION RECORD DRAWING AS -BUILT DATE 10-11-2023 BY VNF DESIGNED BY: DMA ISSUE DATE: 10-11-2023 E . WAS •���� _ y�,y: 0,'� 52125 F�+'•.,�'.�ST6�.• 10-112023 DRAWN BY: DMA JOB NO.: TENW #6002 APPROVED BY: EMS DRAWING FILE NO.: ILLUMINATION GENERAL NOTES 1. THE LOCATION OF ALL CONDUIT, JUNCTION BOXES, AND CABINETS SHOWN ON THIS PLAN ARE APPROXIMATE ONLY. FINAL LOCATION SHALL BE DETERMINED BY THE CONTRACTOR AND CONFIRMED IN THE FIELD BY THE ENGINEER. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, CITY OF RENTON STANDARDS AND WSDOT STANDARDS AND SPECIFICATIONS, CURRENT EDITION. 3. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY. 4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE. 5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY OF RENTON IMMEDIATELY UPON DAMAGE. 7. POLE FOUNDATIONS SHALL NOT BE EXCAVATED AND POURED BEFORE POLE LOCATIONS ARE APPROVED BY THE ENGINEER. 8. ELECTRICAL CONTRACTOR TO CONTACT CITY CONSTRUCTION INSPECTOR FOR INSPECTION OF POLE FOUNDATIONS, BASE BOLTS, AND CABINET FOUNDATION. 9. CONTRACTOR TO CONTACT CITY ELECTRICAL INSPECTOR FOR UNDERGROUND/ROUGH-IN INSPECTION. 10. CONTRACTOR TO CONTACT TRANSPORTATION MAINTENANCE MANAGER FOR STREET LIGHTING COMPLIANCE TO STANDARDS INSPECTION PRIOR TO ENERGIZING. 11. FOLLOWING THE TRANSPORTATION MAINTENANCE INSPECTION, THE CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR SERVICE INSPECTION. 12. FOLLOWING THE SERVICE INSPECTION FROM CITY ELECTRICAL INSPECTOR, ELECTRICAL CONTRACTOR SHALL SUBMIT APPLICATION TO PSE TO ENERGIZE THE STREET LIGHTING. 13. ELECTRICAL CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR FINAL INSPECTION AFTER STREET LIGHTING HAS BEEN ENERGIZED. 14. CONTRACTOR SHALL POTHOLE ALL POLE LOCATIONS TO CONFIRM THAT THERE ARE NO UNDERGROUND CONFLICTS. IF A CONFLICT IS DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO FOUNDATION INSTALLATION. 15. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST ORDER OF BUSINESS, THE CONTRACTOR SHALL CONFIRM THAT THERE ARE NOT CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10-FT CLEARANCE PROVIDED BETWEEN OVERHEAD POWER LINES AND THE PROPOSED LUMINAIRE POLES PRIOR TO POLE PLACEMENT. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED. 16. CONTACT TRANSPORTATION MAINTENANCE MANAGER, ERIC CUTSHALL, 425-430-7423, TO CONNECT NEW STREET LIGHTS TO EXISTING SERVICE CABINET AND COORDINATE WITH PSE FOR SERVICE CABINET METER INSTALLATION BEFORE POWER CAN BE CONNECTED. 17. CITY OF RENTON TRANSPORTATION MAINTANCE MANAGER, ERIC CUTSHALL, WILL PROVIDE POLE NUMBERS FOR CONTRACTOR TO INSTALL AND COORDINATES WILL BE ADDED ON THE AS-BUILTS WHEN COMPLETED. N CALCULATION SUMMARY TARGEACTUAL DESIGN CRITERIA MIN. AVG. MAX. MAINTAINED UNIFORMITY (FC) RATIO CALCULATION AREA (AVG. /MIN.) NE 12TH ST 4.�34 (COLLECTOR) ��1. SUNSET BLVD & 1.50 4.00:1 NE 12TH ST (INTERSECTION) %9TENW Transportation Engineering NorthWest Transportation Planning I Design I Traffic Impact & Operations 11400 SE 8th Street, Suite 200, Bellevue, WA 98004 Office (425) 889-6747 Project Contact: Danielle Allen, P.E. Phone: 425-250-0584 ILLUMINATION LEGEND EX NEW DESCRIPTION ® m JUNCTION BOX TYPE 1 0-4:� LUMINAIRE POLE (COR STD 115) ------ ------ CONDUIT/CONDUCTOR ® SERVICE / CONTROLLER CABINET OCONSTRUCTION NOTE OLUMINAIRE POLE NUMBER KIDDIE RESEARCH, LLC 1025 N 36TH ST. RENTON, WA 98056 KIDZRESEARCH@HOTMAIL.COM YING CHIAO CHEN 10 40 0 20 60 SCALE IN FEET T-411101 DRAWING NO.: KIDDIE RESEARCH DAYCARE IL-01 SHEET NO.: 1 OF ILLUMINATION PLAN 2 SHEETS