Loading...
HomeMy WebLinkAboutW-411103ti N QQ FIRE HYDRANT SHALL BE COREY-TYPE EQUAL TO IOWA F-5110 OR COMPRESSION TYPE SUCH AS CLOW MEDALLION; M & H 929, MUELLER SUPER CENTURION 200, AND WATEROUS PACER WITH 6" MECHANICAL JOINT INLET WITH LUGS. 5-1/4" MAIN VALVE OPENING. TWO 2-1/2" HOSE CONNECTIONS NATIONAL STANDARD THREADS. 4" PUMPER CONNECTION CITY OF SEATTLE THREADS WITH A STORZ ADAPTOR, 4.875" SEATTLE THREAD X 5" STORZ, ATTACHED WITH 1/8" STAINLESS STEEL CABLE. 1-1/4" PENTAGON OPERATING NUT. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF PAINT. KELLY-MOORE/PRESERVATIVE PAINT No. 5780-563 DTM ACRYLIC GLOSS, SAFETY YELLOW OR APPROVED EQUAL. PUMPER CONNECTION TO FACE ROADWAY OR AS DIRECTED BY RENTON FIRE DEPARTMENT. FIRE HYDRANT EXTENSION TO BE USED IF REQUIRED. CURB OR 12" BEHIND BACK OF SIDEWALK THAT IS ADJACENT TO CURB 4.875" x 5" STORZ I 5'x5'x6" THICK CONCRETE PAD AR EXPANSION JOINT AT BACK OF SIDEWALK fCONCRETE SIDEWALK OR PLANTING STRIP MIN. 18" TO 20" BEHIND BACK OF 36" MIN COVER 3' CONCRETE J THRUST BLOCK 16" x 8" x 4" MININUM CONCRETE BEARING BLOCK UNDER HYDRANT 1 �6 CUT �- TWO-PIECE CAST IRON VALVE BOX WITH LUG TYPE COVER. EQUAL TO OLYMPIC FOUNDRY CO. STANDARD 8" TOP SECTION WITH REGULAR BASE SECTION LENGTH TO FIT. VALVE NUT EXTENSION AS REQUIRED. RAISED PAVEMENT MARKER TYPE 88-A STIMSONITE TWO-WAY BLUE REFLECTIVE CONCRETE BLOCKING MAIN LINE TEE. WITH 6" FLANGE SIDE OUTLET. 6" GATE VALVE (FL X MJ) AWWA C-509, RESILIENT SEAT 6 DUCTILE IRON PIPE, CLASS 52 CEMENT LINED, LENGTH TO FIT 2-3/4" COR-TEN STEEL TIE RODS. 1/2 YARD OF 1-1/4" WASHED DRAIN ROCK 1' ABOVE BOOT FLANGE. PLACE 8 MIL POLYETHYLENE FILM AROUND TOP AND SIDES OF GRAVEL. FIRE HYDRANT ASSEMBLY LEVEL ALL GROUND MIN 3' RADIUS 6" CONCRETE PAD LEVEL ALL GROUND MIN 3' RADIUS ONE MAN ROCK 1 6�1?6" CONCRETE PAD FI LL HYDRANT LOCATION IN CUT OR FILL Y STD. PLAN - 310.1 PUBLIC WORKS FIRE HYDRANT ASSEMBLY DEPARTMENT INTO MARCH 2O10 w z �J Q� I w ww 0 010 1r DIRECTION OF FLOW = w - 3„ 11� o (MIN.) 6" MIN. 6"MIN.(TYP.) UNION (TYP.) PLAN X Q 3"MAX. z .0 z 0 0 r� r� 6"MIN. wog o O TO ITY � METER STACKED METER SECTION\-6" MIN. FREE BOXES DRAINING GRAVEL NOTES: 1. ALL DOUBLE CHECK VALVE ASSEMBLIES (DCVA's) MUST BE LISTED ON LATEST LIST OF "BACKFLOW PREVENTION ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2. THE OWNER/APPLICANT MUST OBTAIN A SEPARATE CITY OF RENTON PLUMBING PERMIT FOR THE INSPECTION OF THE INSTALLATION OF THE DCVA AND PIPING. THE OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE DCVA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3. THE DCVA MUST BE TESTED BY A STATE CERTIFIED BACKFLOW ASSEMBLY TESTER AFTER ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S EXPENSE. A COPY OF THE TEST REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT., ATTN: WATER UTILITY CROSS -CONNECTION CONTROL SPECIALIST, FAX NO. 425-430-7241. 4. DCVA AND METER BOX SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. Y PUBLIC WORKS 34" TO 2" DOUBLE CHECK VALVE STD. PLAN - 340.8 a DEPARTMENT ASSEMBLY FOR IRRIGATION OR ANT o. RESIDENTIAL FIRE SPRINKLER MARCH 2O10 MARKER MARKER TWO LANE ROAD OFFSET MARKER TO INDICATE WHICH SIDE OF STREET HYDRANT IS ON (4" FROM DOTS OR PAINTED LINE) 11 MARKER FOUR LANE ROAD OFFSET MARKER TO INDICATE WHICH SIDE OF STREET HYDRANT IS ON (4" FROM DOTS OR PAINTED LANE DIVIDER) HYDRANT MARKERS 4" RAISED PAVMENT MARKER TYPE 88 AB STIMSONITE TWO-WAY (BLUE) MARKER e t o ON SIDE STREETS WHERE THE HYDRANT IS WITHIN 20' OF A MAIN TRAVELED STREET, THE MARKER IS TO BE INSTALLED ON THAT MAIN STREET MARKER T o FIVE LANE ROAD OFFSET MARKER TO INDICATE WHICH SIDE OF STREET HYDRANT IS ON (4" FROM DOTS OR PAINTED LANE DIVIDER) Y STD. PLAN - 310.3 •�° PUBLIC WORKS DEPARTMENT HYDRANT MARKER LAYOUT MARCH 2O10 A A PLAN VIEW WATERIA VALVE BOX LID WITH EARS IN DIRECTION OF 2" SQUARE WATER MAIN AND WORD OPERATING NUT "WATER" CAST INTO IT 12" MIN. 18" MAX, 4" CONCRETE COLLAR FOR VALVES IN PAVED AREAS 4-1/4" DIA. 12" 1/8" MIN. THICKNESS SEE DETAIL 2 PIECE CAST IRON VALVE BOX, RICH-SEATTLE TYPE OR OLYMPIC FOUNDRY 1" STEEL LENGTH AS REQUIRED 1/8" MIN. THICKNESS 2-1/4" INSIDE MEASUREMENT 2-1/4" DEPTH SECTION A -A VALVE OPERATING NUT EXTENSION VALVE OPERATION NUT EXTENSION NOTE: EXTENSIONS ARE REQUIRED WHEN VALVE NUT IS MORE THAN THREE (3) FEET BELOW FINISHED GRADE. EXTENSIONS ARE TO BE A MINIMUM OF ONE (1) FOOT LONG. ONLY ONE EXTENSION TO BE USED PER VALVE. NOTE: ALL EXTENSIONS ARE TO BE MADE OF STEEL, SIZED AS NOTED, AND PAINTED WITH TWO COATS OF METAL PAINT. VALVE MARKER NOTES: VALVE MARKERS SHALL BE EQUAL TO CARSONITE UTILITY MARKER VALVE MARKER POST TO BE USED FOR ALL MAIN LINE VALVES OUTSIDE PAVED AREAS T 38" 62" �Ilill I i� T= 24" VALVE MARKER POST WHITE POSTI PUBLIC WORKS VALVE BOX, MARKER & OPERATING STD. PLAN - 330.1 DEPARTMENT NUT EXTENSION MARCH 2O10 11-1/4' BEND =111111qd� 22-1/2' BEND TEE /I4�- 45' BEND YA 90' BEND THRUST BLOCK BEARING AREA IN SQUARE FEET (SEE NOTES) FOR HORIZONTAL AND DOWNWARD VERTICAL BENDS SOIL FIRM SILT OR FIRM SILTY SAND COMPACT SAND COMPACT SAND & GRAVEL 90' 45' BEND 11 1/4' 90' 45' BEND 11 1/4' 90' 45' BEND 11 1/4' FITTING BEND TEE CAP OR PLUG & 22 1/2' BEND TEE CAP OR PLUG & 22 1/2' BEND TEE CAP OR PLUG & 22 1/2' BEND BEND BEND 4" TO 4.2 4.2 1.7 2.9 2.1 2.1 1.0 2.2 1.6 1.6 1.0 fi" 13.3 9.4 9.4 3.8 6.7 4.7 4.7 1.9 5.0 3.5 3.5 1.4 8" 23.3 16.7 1 16.7 6.7 11.7 8.4 8.4 3.4 8.8 6.3 5.3 2.5 12" 53.0 37.5 37.5 15.0 26.5 18.8 18.8 7.5 2D.D 14.0 14.0 5.6 AREAS CALCULATED ON 300 PSI TEST PRESSURE. S-O" MIN. COVER FOR WATERMAIN LESS THAN 12'. 4'-0" MIN. COVER FOR WATERMAIN 12" OR GREATER. MAX. HEIGHT OF THRUST BLOCK (FT) = 0.5 x DEPTH OF TRENCH MIN. HEIGHT OF THRUST BLOCK (FT) = O.D. PIPE + 1.0' TRUST BLOCK BE. REA REFERS TO 4CE OF BLOCK M IN SQUARE FEET NOTES: 1. LOCATION AND SIZE OF BLOCKING FOR PIPE LARGER THAN 12"DIAMETER AND FOR SOIL TYPES DIFFERENT THAN SHOWN SHALL BE DETERMINED BY THE ENGINEER. 2. ALL BLOCKING SHALL BE POURED IN PLACE AGAINST UNDISTURBED NATIVE GROUND. 3. ALL POURED THRUST BLOCKS SHALL BE BACKFILLED AFTER MIN. 1 DAY. PRESSURE TESTING SHALL OCCUR AFTER CONCRETE HAS REACHED NOMINAL COMPRESSIVE STRENGTH. 4. ALL BLOCKING SHALL BE CONCRETE CL 5 (1-1/2'). 5. BLOCKING AGAINST FITTINGS SHALL BEAR AGAINST THE GREATEST FITTING SURFACE AREA POSSIBLE, BUT SHALL NOT COVER OR ENCLOSE BELL ENDS, JOINT BOLTS OR GLANDS REASONABLE ACCESS TO BOLTS AND GLANDS SHALL BE PROVIDED. �' °� CONCRETE BLOCKING FOR STD. PLAN- 330.2 + �a PUBLIC WORKS �� HORIZONTAL AND DOWNWARD f - DEPARTMENT VERTICAL BENDS MARCH 2O10 -To' CIVIL ENGINEERING Pz LANDSCAPE ARCHITECTURE W PLANNING DESIGN SURVEYING "111111I c4w �O W CORE JOB NO 18227 V 12100 NE 195th St, Suite 300 Bothell, Washington 98017 425.885.7877 W 2/3/23 (DESIGN ONL`I') Rk IN COMPLIANCE WITH CITY OF RENTON STANDARDS QQ� O v o� W-4111 03w-v W SURVEYED: SCALE: DATE: ROBERT WEST HOR VERTICAL- ;98 ;,99, `(/DD/E RESEARCH DAYCARE CENTER MAR. 2020 DESIGNED: CITY OF J123 NE SUNSET BL l/D nELDBOOK: GINA BROOKS O DRAWN: RENTON RENTON, WA 98056 PAGE: DA AID VAUGHN ONE INCH DATU M • DRAWING NO: CHECKED: AT FULL SCALE Planning/Building/Public Works Dept. C5.32 Q GINA BROOKS IF NOT ONE INCH WATER DETAILS NO. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY SHEET: 17 OR21 GINA BROOKS