Loading...
HomeMy WebLinkAboutD_Benson_Trails_Exhibits_Variance_FINALDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Project Location Map D_Benson Trails Variance_FINAL-jc edits A. ADMINISTRATIVE REPORT & DECISION Decision: APPROVED APPROVED SUBJECT TO CONDITIONS DENIED Report Date: May 28, 2020 Project File Number: PR20-000108 Project Name: Benson Trails Variance Land Use File Number: LUA20-000083, V-A Project Manager: Jill Ding, Senior Planner Owner: Trudel, LLC, PO Box 956, Kirkland, WA 98083 Applicant: Wayne Seminoff, The Seminoff Co., PO Box 956, Kirkland, WA 98083 Contact: George Steirer, Plan to Permit, LLC, 7233 Douglas Ave SE, Snoqualmie, WA 98065 Project Location: 18300 121st Pl SE, Renton, WA 98058 Project Summary: The applicant is requesting an administrative variance from the R-4 zone front and side yard setback requirements. The project site totals 3,529 sq. ft. in area and is currently vacant. The R-4 zone requires a front yard setback of 30 feet and a combined side yard setback of 20 feet with not less than 7.5 feet on either side. The applicant is proposing a front yard setback of 15 feet and a combined side yard setback of 14 feet 10 inches with a minimum side yard setback of 5 feet along the west property line. In addition, there is an encroachment easement for the portion of the neighboring home to the east, that was constructed over the abutting lot line onto the subject property. A Category III wetland is mapped offsite to the north of the subject property. The 75-foot standard buffer and 15-foot building setback line extends onto the northern portion of the project site. After deducting the wetland buffer and building setback area, the proposed setbacks would result in a building footprint that is 46.5 feet deep and 20.3 feet wide. Access to the project site is proposed via an existing curb cut off of 121st Pl SE. Site Area: 3,529 sq. ft. (0.08 acres) DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 City of Renton Department of Community & Economic Development Benson Trails Variance Administrative Report & Decision LUA20-000083, V-A Report of May 28, 2020 Page 2 of 9 D_Benson Trails Variance_FINAL-jc edits B. EXHIBITS: Exhibit 1: Administrative Decision Exhibit 2: Site Plan Exhibit 3: Wetland delineation report prepared by Wetlands Northwest, LLC, dated January 23, 2020 Exhibit 4: Variance Request Justification Exhibit 5: Plat Map Exhibit 6: Public Comments and City Response Exhibit 7: Lot Encroachment Easement C. GENERAL INFORMATION: 1. Owner(s) of Record: Trudel, LLC PO Box 956 Kirkland, WA 98083 2. Zoning Classification: Residential-4 (R-4) 3. Comprehensive Plan Land Use Designation: Residential Low Density (LD) 4. Existing Site Use: Vacant 5. Critical Areas: A Category III wetland is mapped offsite to the north of the subject property. 6. Neighborhood Characteristics: a. North: Vacant and R-4 zone b. East: Single family, R-4 zone c. South: Single family, R-4 zone d. West: Single family, R-4 zone 7. Site Area: 3,529 sq. ft. (0.08 acres) D. HISTORICAL/BACKGROUND: Action Land Use File No. Ordinance No. Date Comprehensive Plan N/A 5758 06/22/2015 Zoning N/A 5758 06/22/2015 Annexation N/A 5327 03/01/2008 Benson Trails Plat LUA09-111 N/A 04/08/2010 DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 City of Renton Department of Community & Economic Development Benson Trails Variance Administrative Report & Decision LUA20-000083, V-A Report of May 28, 2020 Page 3 of 9 D_Benson Trails Variance_FINAL-jc edits E. APPLICABLE SECTIONS OF THE RENTON MUNICIPAL CODE: 1. Chapter 2 Land Use Districts a. Section 4-2-020: Purpose and Intent of Zoning Districts b. Section 4-2-060: Zoning Use Table – Uses Allowed in Zoning Designations c. Section 4-2-110: Residential Development Standards d. Section 4-2-115: Residential Design and Open Space Standards 2. Chapter 3 Environmental Regulations and Overlay Districts a. Section 4-3-050: Critical Area Regulations 3. Chapter 4 City-Wide Property Development Standards 4. Chapter 6 Streets and Utility Standards a. Section 4-6-060: Street Standards 5. Chapter 9 Permits – Specific a. Section 4-9-250: Variances, Waivers, Modifications, and Alternates 6. Chapter 11 Definitions F. FINDINGS OF FACT (FOF): 1. The Planning Division of the City of Renton accepted the above master application for review on April 3, 2020 and determined the application complete on April 9, 2020. The project complies with the 120-day review period. 2. The applicant’s submittal materials comply with the requirements necessary to process the administrative variance request (Exhibits 2-7). 3. The project site is located 18300 121st Pl SE, Renton, WA 98058. 4. The project site is currently vacant. Except, a single family homes constructed on the parcel to the east (address) was built over the property line and encroaches onto this site. 5. Access to the site would be provided via a driveway access off of 121st Pl SE. 6. The property is located within the Residential Low Density (LD) Comprehensive Plan land use designation. The project complies with the goals and policies of this Comprehensive Plan land use designation. Compliance Comprehensive Plan Analysis  Policy L-3: Encourage infill development of single-family units as a means to meet growth targets and provide new housing.  Goal L-I: Utilize multiple strategies to accommodate residential growth, including:  Development of new single-family neighborhoods on large tracts of land outside the City Center,  Development of new multi-family and mixed-use in the City Center and in the Residential High Density and Commercial Mixed Use designations, and  Infill development on vacant and underutilized land in established neighborhoods and multi-family areas. DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 City of Renton Department of Community & Economic Development Benson Trails Variance Administrative Report & Decision LUA20-000083, V-A Report of May 28, 2020 Page 4 of 9 D_Benson Trails Variance_FINAL-jc edits  Goal L-U: Preserve, protect, and enhance the quality and functions of the City’s sensitive areas including: lakes, rivers, major and minor creeks, intermittent stream courses and their floodplains, wetlands, ground water resources, wildlife habitats, and areas of seismic and geological hazards.  Policy L-30: Maintain or increase the quantity and quality of wetlands. Development activities shall not decrease the net acreage of existing wetlands.  Policy L-31: Protect buffers along wetlands and surface waters to facilitate infiltration and maintain stable water temperatures, provide for biological diversity, reduce amount and velocity of run-off, and provide for wildlife habitat.  Goal L-BB: Maintain a high quality of life as Renton grows by ensuring that new development is designed to be functional and attractive.  Goal L-FF: Strengthen the visual identity of Renton and its Community Planning Areas and neighborhoods through quality design and development.  Policy L-48: Address privacy and quality of life for existing residents by considering scale and context in infill project design. 7. The site is located within the Residential-4 (R-4) zoning classification. 8. There are no significant trees on the project site. 9. A Category III wetland is mapped offsite to the north of the subject property. 10. The applicant is proposing to begin construction in summer 2020 and end in fall 2020. 11. The following variances to RMC4-2-110A have been requested by the applicant: RMC Code Citation Required Standard Requested Variance RMC 4-2-110A Residential Development Standards The R-4 zone requires a front yard setback of 30 feet and a combined side yard setback of 20 feet with not less than 7.5 feet on either side. The applicant is proposing a front yard setback of 15 feet and a combined side yard setback of 14 feet 10 inches with a minimum side yard setback of 5 feet along the west property line. 12. Staff received 2 public comment emails and staff provided responses to each individual comment (Exhibit 6). 13. This variance application is only considering setbacks and does not include a review or approval of any submitted floor plans or building elevations that may have been submitted. 14. Representatives from various city departments have reviewed the application materials to identify and address issues raised by the proposed development. These comments are contained in the official file, and the essence of the comments has been incorporated into the appropriate sections of this report and the Departmental Recommendation at the end of this report. 15. Critical Areas: Project sites which contain critical areas are required to comply with the Critical Areas Regulations (RMC 4-3-050). The proposal is consistent with the Critical Areas Regulations, if all conditions of approval are complied with: Compliance Critical Areas Analysis DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 City of Renton Department of Community & Economic Development Benson Trails Variance Administrative Report & Decision LUA20-000083, V-A Report of May 28, 2020 Page 5 of 9 D_Benson Trails Variance_FINAL-jc edits Compliant if conditions of approval are met Wetlands: The following buffer requirements are applicable to wetlands in accordance with RMC 4-3-050.G.2: Wetland Category Buffer Width Structure Setback beyond buffer High Habitat Function (8- 9 points) Moderate Habitat Function (5- 7 points) Low Habitat Function (3-4 points) All Other Scores 15 ft. Category I – Bogs & Natural Heritage Wetlands 200 ft. Category I – All Others 200 ft. 150 ft. 115 ft. 115 ft. Category II 175 ft. 150 ft. 100 ft. n/a Category III 125 ft. 100 ft. 75 ft. n/a Category IV 50 ft. n/a Staff Comment: A wetland delineation report prepared by Wetlands Northwest, LLC, dated January 23, 2020 (Exhibit 3) was submitted with the project application materials. A Category III wetland is mapped offsite to the north of the subject property. The 75-foot standard buffer and 15-foot building setback line extend onto the northern portion of the project site. No buffer reductions of buffer averaging is proposed. Fencing and signage is required along the wetland buffer edge, in addition wetland buffers are required to be placed within a Native Growth Protection Easement. Staff recommends, as a condition of approval that the edge of the wetland buffer be delineated within a split rail fence and signage in accordance with RMC 4-3-050. A fencing and signage detail shall be submitted to the Current Planning Project Manager for review and approval at the time of Building Permit review. Staff also recommends, as a condition of approval, that a Native Growth Protection Easement be submitted for review and approval to the Current Planning Project Manager at the time of Building Permit review. The easement shall be recorded prior to permit issuance. 16. Variance Analysis: The applicant has requested a variance from the R-4 zone front and side yard setback requirements. The R-4 zone requires a front yard setback of 30 feet and a combined side yard setback of 20 feet with not less than 7.5 feet on either side. The applicant is proposing a front yard setback of 15 feet and a combined side yard setback of 14 feet 10 inches with a minimum side yard setback of 5 feet along the west property line. The proposal as amended by staff is compliant with the following variance criteria, pursuant to RMC 4-9-250.B.5. Therefore, staff recommends approval of the variance as amended below. Compliance Variance Criteria and Analysis compliant if conditions of approval are met a. That the applicant suffers practical difficulties and unnecessary hardship and the variance is necessary because of special circumstances applicable to subject property, including size, shape, topography, location or surroundings of the subject property, and the strict application of the Zoning Code is found to deprive subject property owner of rights and privileges enjoyed by other property owners in the vicinity and under identical zone classification. Staff Comment: The applicant contends that practical difficulties exist on the project site as it is difficult to apply the R-4 setback requirements on a 3,529 square foot lot. The minimum lot size DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 City of Renton Department of Community & Economic Development Benson Trails Variance Administrative Report & Decision LUA20-000083, V-A Report of May 28, 2020 Page 6 of 9 D_Benson Trails Variance_FINAL-jc edits required within the R-4 zone is 9,000 square feet, the existing 3,529 square foot lot is less than half of the minimum lot size required. The minimum lot width in the R-4 zone is 70 feet and the minimum lot depth is 100 feet. The existing lot has a width of 35 feet and a depth of 98 feet. The existing lot width is half the minimum lot width required in the R-4 zone. The R-4 zone requires a front yard setback of 30 feet and a combined side yard setback of 20 feet with not less than 7.5 feet on either side. The applicant is proposing a front yard setback of 15 feet and a combined side yard setback of 14 feet 10 inches with a minimum side yard setback of 5 feet along the west property line. The proposed setbacks would result in a building footprint that is 46.5 feet deep and 20.3 feet wide. Staff concurs that the applicant suffers practical difficulties to implement the R-4 setback requirements on an existing lot with an area and width that are substantially less than the minimum required in the R-4 zone. The existing homes on neighboring lots appear to have 20- foot front yard setbacks. In addition, staff has concerns that there does not appear to be adequate area on the public right-of-way fronting the project site for vehicle parking. Therefore staff does not concur that a 15-foot front yard setback would be appropriate for the project site, but that a 20-foot front yard setback, consistent with other neighboring residences, would provide an adequate front yard and provide adequate area on the driveway for vehicle parking. Staff recommends approval of a minimum front yard setback of 20 feet instead of the requested 15 feet, with an allowance for a 2 ft. eave projection into all setbacks. Staff has concerns with regards to the neighboring residence to the east, which extends over the east property line and onto the project site. An easement was recorded to address the encroachment as well as a setback (Exhibit 7). To bring the properties into conformance with City standards, a lot line adjustment should be recorded to reflect the easement line that was recorded to address the encroachment. The lot line adjustment would result in a reduction in the area of the subject property below the 9,000 square foot minimum lot size permitted within the R-4 zone. This lot area reduction would meet the practical difficulty criteria as the reduction would rectify an existing encroachment. Staff recommends, as a condition of approval, that a lot line adjustment be recorded prior to the issuance of a building permit to reflect the easement line that was recorded to address the encroachment. After the recording of a lot line adjustment as conditioned above, the requested 9’-10” side yard setback from the east property line would not provide sufficient area for a single family residence with an adequate entry feature that would allow the home to conform to the City’s residential design guidelines, RMC 4-2-115. After the recording of the lot line adjustment, a side yard setback ranging from 3 feet in front to 1-foot in the rear (where the side lot line intersects with the 15-foot wetland buffer building setback line) be granted along the east property line would provide adequate area for an entry feature as required in RMC 4-2-115. Therefore, staff recommends that the side yard setback from the east property line be reduced from the requested 9’-10” to a range of 3 feet in front to 1-foot in the rear (where the side lot line intersects with the 15-foot wetland buffer building setback line) along the east property line. Staff concurs that the requested 5 foot setback from the west property line would be necessary to provide for a reasonable home on this substandard R-4 lot. The 5-foot side yard setback is consistent with other homes in the neighborhood. Based on the lot dimensions staff believes that any single family residence proposed on the project site would have a front façade that is primarily consisting of a 2 car garage. To provide an entry feature along the front façade of the single family residence, staff recommends that a porch and residential entry be provided with a minimum width of 5 feet and that the porch be permitted to project 5 feet into the recommended 20-foot front yard setback. compliant if conditions of approval are met b. That the granting of the variance will not be materially detrimental to the public welfare or injurious to the property or improvements in the vicinity and zone in which subject property is situated. Staff Comment: The applicant contends that the requested setbacks would allow for the construction of a single family residence on the project site that would be slightly smaller and DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 City of Renton Department of Community & Economic Development Benson Trails Variance Administrative Report & Decision LUA20-000083, V-A Report of May 28, 2020 Page 7 of 9 D_Benson Trails Variance_FINAL-jc edits have similar setbacks to other residences within the same neighborhood and would therefore not be injurious to surrounding property owners. After review staff believes that a 15-foot front yard setback would be injurious to the public welfare as it could result in a vehicle parked in the driveway extending into the cul-de-sac. The cul-de-sac is necessary for fire emergency access turn around and obstructions in this area could impact the health and safety of the neighbors if vehicle encroachments hindered emergency response. A typical vehicle parking stall is 20 feet in depth, therefore staff is recommending a setback variance of 20 feet in the front yard. The east side yard setback that ranges of 3 feet in front to 1-foot in the rear (where the side lot line intersects with the 15-foot wetland buffer building setback line) along the east property line and the request 5-foot west side yard setback would not be injurious to surrounding property owners. In addition, the recommended lot line adjustment, which would result in a reduce lot area for the subject property would rectify an existing situation and would not be injurious to surrounding properties. compliant if conditions of approval are met c. That approval shall not constitute a grant of special privilege inconsistent with the limitation upon uses of other properties in the vicinity and zone in which the subject property is situated. Staff Comment: The applicant contends that the requested variance would not be a grant of special privilege as the requested setbacks would permit the construction of a single family residence that would have a slightly smaller building footprint that other residences in the immediate vicinity. Homes in the neighborhood primarily have a front yard setback of 20 feet and a side yard setback of 5 feet. The requested variance for a 15-foot front yard setback would not be consistent with the adjacent properties and would constitute a grant of special privilege. However, if this setback is increased to 20 feet the home would be built consistent with others in the vicinity, therefore a 20-foot front yard setback would not constitute a grant of special privilege inconsistent with the other properties in the vicinity and zone. The reduced side yard setbacks, of 5 feet on the west ,which ranges of 3 feet in front to 1-foot in the rear (where the side lot line intersects with the 15-foot wetland buffer building setback line) along the east property line would not constitute a grant of special privilege inconsistent with the laminations upon uses of other properties. The reduced side yard setback is necessary to provide for a two car garage and a 5-foot wide entry to the home. All other homes in the vicinity have been built with a two car garage and a front entry along the street. In addition, the recommended lot line adjustment, which would result in a reduce lot area for the subject property, would rectify an existing situation and would not be a grant of special privilege. compliant if conditions of approval are met d. That the approval is a minimum variance that will accomplish the desired purpose. Staff Comment: The applicant contends that the requested variance is the minimum necessary to allow for the construction of a single family residence on the project site that would be of comparable size to other existing single family residences in the vicinity. Staff concurs that the requested variance, as modified above would be the minimum variance necessary to allow for the construction of a single family residence on the project site. In addition, the recommended lot line adjustment, which would result in a reduce lot area for the subject property, would be the minimum necessary to rectify an existing situation. G. CONCLUSIONS: 1. The subject site is located in the Residential Low Density (LD) Comprehensive Plan designation and complies with the goals and policies established with this designation, see FOF 6. 2. The proposed variance application complies with the Critical Areas Regulations provided the applicant complies with City Code and conditions of approval, see FOF 14. DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 City of Renton Department of Community & Economic Development Benson Trails Variance Administrative Report & Decision LUA20-000083, V-A Report of May 28, 2020 Page 8 of 9 D_Benson Trails Variance_FINAL-jc edits 3. The variance as modified and conditioned by Staff meets the four (4) criteria to be considered in making a decision on a variance request as specified in RMC 4-9-250.B.5. The analysis of the proposal according to variance criteria is found in the body of the Staff Report, see FOF 15. H. DECISION: The Benson Trails Variance, File No. LUA20-000083, V-A, is approved for a 20-foot front yard setback with a 5- foot allowance for a porch projection, a 5-foot side yard setback from the west property line, a side yard setback ranging from 3 feet in front to 1-foot in the rear (where the side lot line intersects with the 15 -foot wetland buffer building setback line) along the east property, a 2 foot eve projection into all setbacks, and a reduced minimum lot size to accommodate the required lot line adjustment. The approved variance is subject to the following conditions: 1. The edge of the wetland buffer shall be delineated within a split rail fence and signage in accordance with RMC 4-3-050. A fencing and signage detail shall be submitted to the Current Planning Project Manager for review and approval at the time of Building Permit review. 2. A Native Growth Protection Easement shall be submitted for review and approval to the Current Planning Project Manager at the time of Building Permit review. The easement shall be recorded prior to permit issuance. 3. A lot line adjustment shall be recorded prior to the issuance of a building permit to reflect the easement line, as shown in Exhibit 7, which was recorded to address the encroachment. 4. A porch and residential entry shall be provided in the home design with a minimum width of 5 feet. Compliance with this conditions would be reviewed and approved with the building permit application. DATE OF DECISION ON LAND USE ACTION: SIGNATURE: Jennifer Henning, Planning Director Date TRANSMITTED on May 28, 2020 to the Owner/Applicant/Contact: Owner: Applicant: Contact: Trudel, LLC PO Box 956 Kirkland, WA 98083 Wayne Seminoff The Seminoff Co. PO Box 956 Kirkland, WA 98083 George Steirer Plan to Permit, LLC 7233 Douglas Ave SE Snoqualmie, WA 98065 TRANSMITTED on May 28, 2020 to the Parties of Record: Natalie Wissbrod Soccergirl42nw@gmail.com Jocelyn Nicholson Njocie@comcast.net TRANSMITTED on May 28, 2020 to the following: Chip Vincent, CED Administrator Brianne Bannwarth, Development Engineering Manager DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 5/28/2020 | 2:18 PM PDT City of Renton Department of Community & Economic Development Benson Trails Variance Administrative Report & Decision LUA20-000083, V-A Report of May 28, 2020 Page 9 of 9 D_Benson Trails Variance_FINAL-jc edits Amanda Askren, Property Services Vanessa Dolbee, Current Planning Manager Anjela Barton, Fire Marshal I. LAND USE ACTION APPEALS, REQUEST FOR RECONSIDERATION, & EXPIRATION: The administrative land use decision will become final if the decision is not appealed within 14 days of the decision date. APPEAL: This administrative land use decision will become final if not appealed in writing to the Hearing Examiner on or before 5:00 PM on June 11, 2020. An appeal of the decision must be filed within the 14-day appeal period (RCW 43.21.C.075(3); WAC 197-11-680), together with the required fee to the Hearing Examiner, City of Renton, 1055 South Grady Way, Renton, WA 98057. RMC 4-8-110.B governs appeals to the Hearing Examiner and additional information regarding the appeal process may be obtained from the City Clerk’s Office, (425) 430-6510. Due to Governor Jay Inslee’s Proclamation 20-25 (“Stay Home, Stay Healthy”), the City Clerk’s Office is working remotely. For that reason, appeals must be submitted electronically to the City Clerk at cityclerk@rentonwa.gov. The appeal fee, normally due at the time an appeal is submitted, will be collected at a future date. Appeals to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov. If the situation changes such that the City Clerk’s Office is open when you file your appeal, you have the option of filing the appeal in person. EXPIRATION: The Variance decision will expire two (2) years from the date of decision. A single one (1) year extension may be requested pursuant to RMC 4-9-250. RECONSIDERATION: Within 14 days of the decision date, any party may request that the decision be reopened by the approval body. The approval body may modify his decision if material evidence not readily discoverable prior to the original decision is found or if he finds there was misrepresentation of fact. After review of the reconsideration request, if the approval body finds sufficient evidence to amend the original decision, there will be no further extension of the appeal period. Any person wishing to take further action must file a formal appeal within the 14-day appeal time frame. THE APPEARANCE OF FAIRNESS DOCTRINE: provides that no ex parte (private one-on-one) communications may occur concerning the land use decision. The Doctrine applies not only to the initial decision, but to Appeals to the Hearing Examiner as well. All communications after the decision/approval date must be made in writing through the Hearing Examiner. All communications are public record and this permits all interested parties to know the contents of the communication and would allow them to openly rebut the evidence in writing. Any violation of this doctrine could result in the invalidation of the appeal by the Court. DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 CITY OF RENTON DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT ADMINISTRATIVE REPORT & DECISION EXHIBITS Project Name: Benson Trails Variance Land Use File Number: LUA20-000083, V-A Date of Report May 28, 2020 Staff Contact Jill Ding Senior Planner Project Contact/Applicant George Steirer Plan to Permit, LLC 7233 Douglas Ave SE, Snoqualmie, WA 98065 Project Location 18300 121st Pl SE, Renton, WA 98058 The following exhibits are included with the Administrative report: Exhibit 1: Administrative Decision Exhibit 2: Site Plan Exhibit 3: Wetland delineation report prepared by Wetlands Northwest, LLC, dated January 23, 2020 Exhibit 4: Variance Request Justification Exhibit 5: Plat Map Exhibit 6: Public Comments and City Response Exhibit 7: Lot Encroachment Easement DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 0'10'EXISTING HOUSEEXISTING HOUSESCALE: 1" = 10' AGENT: GEORGE STEIRER – PLAN TO PERMIT, LLC George@plantopermit.com 206-909-2893 www.PlanToPermit.com OWNER: TRUDEL, LLC DATE: 08/28/2019 REV1: 03/30/2020 REV2: REV3: REV4 REV5: REV6: REV7: SHEET SP1.0DISCLAIMER: The information is provided for preliminary purposes only. Plan to Permit, LLC, its officers, employees or agents make no warranty of any kind, express or implied, regarding the accuracy of the information. PROJECT NAME: BENSON TRAILS VARIANCE DESCRIPTION: DEVELOP EXISTING VACANT LOT FOR A SINGLE FAMILY RESIDENCE SITE ADDRESS: 18300 121st PL SE, RENTON, WA PIN: 07415-0080 SECTION: 33 TOWNSHIP: 25 RANGE: 05 EXHIBIT 2 RECEIVED 04/03/2020 jding PLANNING DIVISION DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 Wetlands Northwest LLC 5218 Ivanhoe PL NE Seattle, WA 98105 206-456-5474 www.wetlandsnw.com January 23, 2020 Wayne Seminoff PO Box 956 Kirkland, 98063 Re: King County Tax Parcel 074150-0080 18300 121st Pl SE, Renton, WA 98058 Dear Mr. Seminoff, Following my site visit on January 20, 2020, I have determined that the off-site wetland is Category III scoring 18 points overall which include 3 habitat points. The required buffer for this type of wetland is 75 feet per the Renton Municipal Code Title 4-3-050.G.2 referenced in the table below. EXHIBIT 3 DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 www.PlanToPermit.com george@PlanToPermit.com 206-909-2893 Angelea Weihs, Associate Planner City of Renton 1055 S. Grady Way Renton, WA 98057 RE: Benson Trails Variance at 18300 121st PL (07415-0080)) August 20, 2019 Dear Angelea: Below are the criterion of approval for a variance (in bold) per RMC 4-9-250.B.5, followed by a response on how the application meets the criterion (in blue italics): A. That the applicant [i] suffers practical difficulties and unnecessary hardship and the variance is necessary because of special circumstances applicable to subject property, including size, shape, topography, location or surroundings of the subject property, and [ii] the strict application of the Zoning Code is found to deprive subject property owner of rights and privileges enjoyed by other property owners in the vicinity and under identical zone classification; Responses: i. An entirely unrelated contractor, to the east, constructed a significant portion of a building onto the subject parcel. Although this eastern building crosses the subject property line, the permit for the eastern building was finaled by the City of Renton. This intrusion affects the building area for the subject property. The subject property also contains an ingress/egress easement at the south east portion of the property that further reduces the size of the building envelope. These unusual, and “special circumstances applicable to the subject property” create practical difficulties and unnecessary hardship to meet the city’s setback requirements due to the resulting narrow and small envelope space. The resulting building envelope, with standard setbacks and the encroachment, is significantly smaller than other building envelopes. This would significantly impair the ability to provide a single family home and associated appurtenances that are allowed on the other lots in the vicinity and R-4 zone. The strict application of the setbacks are not necessary to maintain life safety. Please see the responses to the second criterion of approval, below, for further discussion. Thus, the strict application of the setback standards make the siting of the home more difficult, and harder, then necessary. ii. The site is located in the R4 zoning district, which allows 35% building coverage (RMC 4-2-110A). The standard setbacks would only allow 21% building coverage. The front, rear, and east sides of the 21% area are irregularly shaped, and result in unfunctional (dead) building space. This is significantly lower than the building coverage allowed to other property owners in the vicinity and the identical R4 zoning classification. Therefore, the building encroachment and standard setbacks deprives the subject property owner of a right and privilege (building coverage, accessory uses, etc.), which is enjoyed by other property owners in the vicinity and under the identical R4 zone classification. EXHIBIT 4 DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 08/20/2019 Page 2 of 2 Plan to Permit, LLC B. That the granting of the variance will not be materially detrimental to the public welfare or injurious to the property or improvements in the vicinity and zone in which subject property is situated; Response: The new home will comply with the latest building code, fire code, and other life safety standards. This includes the minimum required separation between single-family residences, per the codes. The stormwater requirements will be complied with for the proposal. The reduced setbacks would easily allow for the clear vision area, as prescribed in RMC 11-30-030, to be met. Thus, safe ingress and egress is not impaired by the reduced setbacks. Therefore, granting the variance will not be injurious to the property or improvements in the vicinity and zone as the proposed home will not impact the existing uses or potential uses of the adjacent properties. C. That approval shall not constitute a grant of special privilege inconsistent with the limitation upon uses of other properties in the vicinity and zone in which the subject property is situated; Response: The criteria for approval states “with the limitation upon uses of other properties in the vicinity and zone”. The underlying zone is R4, which allows single family homes as a use. The proposed variance would allow a single family residence, and accessory uses, consistent with other uses in the vicinity and the zone. The special circumstance is a result by another property owner, and not the owner of the subject property. D. That the approval is a minimum variance that will accomplish the desired purpose. Response: The reduced setbacks are the minimum necessary to allow for a garage, and meet the Renton design requirements for it to be recessed. We also note that the proposed house design has a smaller building footprint than any other building in the vicinity, based on King County Department of Assessments information. Thank you for your time, attention to this letter, and assistance. Please feel free to contact me at george@plantopermit.com if you have any questions or need any additional information. Sincerely George Steirer Plan to Permit, LLC DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 EXHIBIT 5 EXHIBIT 5 DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 From: Jill Ding Sent: Monday, May 04, 2020 9:23 AM To: 'Njocie' Subject: RE: Notice of Application- Number LUA20-000083, V-A Jocelyn, Thank you for your comments, your comments have been added to the official file for consideration by the decision maker. I have also added you as a party of record for this project, as a party of record, you will receive copies of City correspondence for this project as well as any decisions that are issued. Regarding your specific questions: 1. This project is to allow the construction of a single family residence on a separate legal lot. There should be no direct construction related impacts to your property. 2. As this property is an existing legal lot, the property owner is entitled to reasonable use of their property, which includes the construction of a single family residence. 3. You will be informed of future decisions as a party of record. Thanks, Jill Ding Senior Planner City of Renton Community and Economic Development 6th floor 1055 S Grady Way Renton, WA 98057 425-430-6598 jding@rentonwa.gov City of Renton Census Information: rentonwa.gov/2020census Here is a link to the City of Renton PSA Video: Renton Counts Links to additional resources: https://2020census.gov/ To complete your 2020 census: https://my2020census.gov/ EXHIBIT 6 DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 From: Njocie <Njocie@comcast.net> Sent: Friday, May 01, 2020 7:01 AM To: Jill Ding <JDing@Rentonwa.gov> Subject: Notice of Application- Number LUA20-000083, V-A Good morning Jill, My name is Jocelyn Nicholson and owner of property APR 0741500170 and would like to understand 1) impacts of subject application request to my property. 2) What is required to revoke request 3) how to be informed of any and all future changes and request. Due to Covid - 19, I am just reading about this request and was unaware of request changes and inputs required by 5pm on April 23th . I can be reached at 425 392-8003 (h) or 206 200-2750 cell. Thank you Jocelyn Nicholson Sent from my Verizon, Samsung Galaxy smartphone DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 From: Jill Ding Sent: Monday, April 27, 2020 9:27 AM To: 'Natalie Wissbrod' Subject: RE: PR20-000108 / LUA20-000083 V-A Natalie, Thank you for your comments. Your comments have been added to the official file for consideration by the decision maker. In addition, you have been added as a party of record for this project, this means you will receive copies of City correspondence as well as any decisions issued on this project. While the City cannot prohibit anyone from obtaining a building permit to build on an existing legal lot, we can review the setbacks that have been requested. Per your concerns regarding the proximity of the new home to the sidewalk, the City will also be reviewing this setback request and will take your comments into consideration. Please let me know if you have additional questions. Thanks, Jill Ding Senior Planner City of Renton Community and Economic Development 6th floor 1055 S Grady Way Renton, WA 98057 425-430-6598 jding@rentonwa.gov City of Renton Census Information: rentonwa.gov/2020census Here is a link to the City of Renton PSA Video: Renton Counts Links to additional resources: https://2020census.gov/ To complete your 2020 census: https://my2020census.gov/ DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 From: Natalie Wissbrod <soccergirl42nw@gmail.com> Sent: Thursday, April 23, 2020 12:13 PM To: Jill Ding <JDing@Rentonwa.gov> Subject: PR20-000108 / LUA20-000083 V-A Unless you live in our tiny little cul-de-sac you may not get how tight the conditions already are without yet another house thrown into the mix. There is hardly any parking if they have extra vehicles and there is no curb room for any more garbage cans. In my opinion, the house will look out of place. Our houses are already close to the sidewalk and this one sounds like it will right up to the sidewalk. During construction there is no room for regular traffic and big construction vehicles. If there was an emergency access would be blocked. There are a lot of people teleworking now and keeping odd hours, to have a lot of noisy construction work going on so closely would be a big disturbance. Thank you for listening to my thoughts on this matter. DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 EXHIBIT 7 DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78 DocuSign Envelope ID: 99C5BE37-DA78-4AF0-A450-9E101B6A8B78