Loading...
HomeMy WebLinkAboutExh.18_Elevation_Plan_Sheets_Black_and_WhiteElevation General Notes1.ALL STONE VENEER, PLASTER, WOOD SIDING, TRIMS,FLASHINGS, ETC. TO BE INSTALLED PER MANUF.SPECIFICATIONS.2.FOR ROOF VENT & GUTTER PLAN REFER TO ROOFPLAN3.FOR MORE ELEVATION DATUM MARKS REFER TOBUILDING AND WALL SECTIONS4.REFER TO ELEC. & MECH. PLANS FOR EXTERIORLIGHT FIXTURE LOCATIONS5. WINDOW MARK - SEE DOOR AND WINDOW SCHEDULE SHEETElevation Keyed Notes312ASPHALT SHINGLES - SEE SECTIONS5/4" PRIMED FASCIA - SEE SECTIONS FOR EAVE AND RAKEDETAILSPRE-FINISHED ALUMINUM GUTTERPRE-FINISHED 2X3 ALUMINUM DOWNSPOUTALUMINUM DOWNSPOUT STRAPEXPOSED CONC. PLINTH OVERDRAIN TO FOUNDATION TITE-LINE SYSTEM (TYP.)VERTICAL BOARD AND BATTEN @ 12" O.C.6" LAP WOOD SIDING12" LAP HORIZONTAL CHANNEL RUSTIC SIDING (DARKCOLOR)8" WIDE BOXED POPOUT LEG - FINISH TO MATCH ABV.THREE COAT CEMENT PLASTER, 78" THICK (MIN.)2" PLASTER REVEAL2" PLATER REVEAL AND DRIP MOLDING10" STUCCO BANDWOOD BAND / TRIMSMOOTH WOOD FINISHEXPOSED POST / BEAM, W/ HARDIEPANEL WRAP (NON-STRUCTURAL)METAL RAILING AT 36" ABOVE FIN. FLR. (MIN.)WINDOW, REFER TO FLOOR PLANDOOR, REFER TO FLOOR PLANHEAT PUMP OVER 6" PADHORIZONTAL HARDIE BOARD AND BATTEN @ 12" O.C.COLOR PANELS AT 36" STAGGERED SEGMENTS TOREPRESENT A BRICK-LIKE APPEAL4567891011121314151617X18192021221A-3.1323Key Plan3rd FloorN1A1B1C1D1EUNITUNITUNITUNITUNIT1A4.011A4.02FEDCBAT.O.S./ T.O.F0'-0"TOP PL. 8'-238"T.O. FL.9'-3"TOP PL.26'-838"TOP PL. 17'-538"T.O. FL.18'-6"34'-4"LOW ROOF36'-10"HIGH ROOF36'-4"MID ROOFEEEECCCCCCCCCEEECCCCCCCCCCCCCC123DDBBT.O.S./ T.O.F0'-0"TOP PL. 8'-238"T.O. FL.9'-3"TOP PL.26'-838"TOP PL. 17'-538"T.O. FL.18'-6"34'-4"LOW ROOF36'-10"HIGH ROOF36'-4"MID ROOFEE1A4.021620 84th Ave. S.Ste. 200Kent, WA 98032(253) 468-7696www.ihbarchitects.comHF, NSThe drawings and plans set forth onthis set as instrument of service are,and shall remain, the property of IHBArchitects. Use of this drawing islimited to a specified project forpersons named hereon. And for aconstruction of one building. Anyuse or reuse of said drawings isstrictly prohibited without writtenpermission of IHB Architectsdrawn by:May 20, 2019date:-job No:IHBreviewed by:revisions:SUNRIDGE TOWNHOMES II 1222XX SE PERTOVITSKY RD RENTON, WA 98058 PARCEL NO: 0739000050 1A4.0 SOUTH-WEST SIDE ELEVATION PLANLEFT ELEVATION - WEST SIDESCALE: 1/4" = 1'-0"FRONT ELEVATION - SOUTH SIDESCALE: 1/4" = 1'-0"12RECEIVED02/10/2020 mherreraPLANNING DIVISIONDocuSign Envelope ID: 6FEDE754-AC7F-4A9A-847E-EDB66D55B606 123T.O.S./ T.O.F0'-0"TOP PL. 8'-238"T.O. FL.9'-3"TOP PL.26'-838"TOP PL. 17'-538"T.O. FL.18'-6"34'-4"LOW ROOF36'-10"HIGH ROOF36'-4"MID ROOFDDBBElevation General Notes1.ALL STONE VENEER, PLASTER, WOOD SIDING, TRIMS,FLASHINGS, ETC. TO BE INSTALLED PER MANUF.SPECIFICATIONS.2.FOR ROOF VENT & GUTTER PLAN REFER TO ROOFPLAN3.FOR MORE ELEVATION DATUM MARKS REFER TOBUILDING AND WALL SECTIONS4.REFER TO ELEC. & MECH. PLANS FOR EXTERIORLIGHT FIXTURE LOCATIONS5. WINDOW MARK - SEE DOOR AND WINDOW SCHEDULE SHEETElevation Keyed Notes312ASPHALT SHINGLES - SEE SECTIONS5/4" PRIMED FASCIA - SEE SECTIONS FOR EAVE AND RAKEDETAILSPRE-FINISHED ALUMINUM GUTTERPRE-FINISHED 2X3 ALUMINUM DOWNSPOUTALUMINUM DOWNSPOUT STRAPEXPOSED CONC. PLINTH OVERDRAIN TO FOUNDATION TITE-LINE SYSTEM (TYP.)VERTICAL BOARD AND BATTEN @ 12" O.C.6" LAP WOOD SIDING12" LAP HORIZONTAL CHANNEL RUSTIC SIDING (DARKCOLOR)8" WIDE BOXED POPOUT LEG - FINISH TO MATCH ABV.THREE COAT CEMENT PLASTER, 78" THICK (MIN.)2" PLASTER REVEAL2" PLATER REVEAL AND DRIP MOLDING10" STUCCO BANDWOOD BAND / TRIMSMOOTH WOOD FINISHEXPOSED POST / BEAM, W/ HARDIEPANEL WRAP (NON-STRUCTURAL)METAL RAILING AT 36" ABOVE FIN. FLR. (MIN.)WINDOW, REFER TO FLOOR PLANDOOR, REFER TO FLOOR PLANHEAT PUMP OVER 6" PADHORIZONTAL HARDIE BOARD AND BATTEN @ 12" O.C.COLOR PANELS AT 36" STAGGERED SEGMENTS TOREPRESENT A BRICK-LIKE APPEAL4567891011121314151617X18192021221A-3.1323Key Plan3rd FloorN1A1B1C1D1EUNITUNITUNITUNITUNIT1A4.111A4.12FEDCABT.O.S./ T.O.F0'-0"TOP PL. 8'-238"T.O. FL.9'-3"TOP PL.26'-838"TOP PL. 17'-538"T.O. FL.18'-6"34'-4"LOW ROOF36'-10"HIGH ROOF36'-4"MID ROOFEEEEECCCCCCCCCCCCCCCCCCCCCCCCCNOTE:FOR OTHER NOTES, BUILDINGHEIGHTS AND ELEVATION MARKS,AND DETAILS SEE SHEET 2A4.11A4.121620 84th Ave. S.Ste. 200Kent, WA 98032(253) 468-7696www.ihbarchitects.comHF, NSThe drawings and plans set forth onthis set as instrument of service are,and shall remain, the property of IHBArchitects. Use of this drawing islimited to a specified project forpersons named hereon. And for aconstruction of one building. Anyuse or reuse of said drawings isstrictly prohibited without writtenpermission of IHB Architectsdrawn by:May 20, 2019date:-job No:IHBreviewed by:revisions:SUNRIDGE TOWNHOMES II 1222XX SE PERTOVITSKY RD RENTON, WA 98058 PARCEL NO: 0739000050 1A4.1 NORTH-EAST SIDE ELEVATION PLANRight Elevation - East SideSCALE: 1/4" = 1'-0"Rear Elevation - North SideSCALE: 1/4" = 1'-0"12RECEIVED02/10/2020 mherreraPLANNING DIVISIONDocuSign Envelope ID: 6FEDE754-AC7F-4A9A-847E-EDB66D55B606 T.O.S./ T.O.F0'-0"TOP PL. 8'-238"T.O. FL.9'-3"TOP PL.26'-838"TOP PL. 17'-538"T.O. FL.18'-6"34'-4"LOW ROOF36'-10"HIGH ROOF36'-4"MID ROOFABCDEFGHJEEEEEEBBBEEBESection Keyed NotesNLRFOUNDATION WALL - SEE STRUCTURAL DETAILSRBFNDBMBEAM PER FRAMING PLANSPROVIDE 2x GYP./PLY NAILERS WHERE REQ'DRIM BOARD PER FRAMING PLANR-30 FLOOR INSULATIONR30* Refer to sheet A-0.1 forFire Rated AssembliesT.O.S./ T.O.F0'-0"TOP PL. 8'-238"T.O. FL.9'-3"TOP PL.26'-838"TOP PL. 17'-538"T.O. FL.18'-6"34'-4"LOW ROOF36'-10"HIGH ROOF36'-4"MID ROOF789BBB654321EEEEEEEEEEEEBElevation General Notes1.ALL STONE VENEER, PLASTER, WOOD SIDING, TRIMS,FLASHINGS, ETC. TO BE INSTALLED PER MANUF.SPECIFICATIONS.2.FOR ROOF VENT & GUTTER PLAN REFER TO ROOFPLAN3.FOR MORE ELEVATION DATUM MARKS REFER TOBUILDING AND WALL SECTIONS4.REFER TO ELEC. & MECH. PLANS FOR EXTERIORLIGHT FIXTURE LOCATIONS5. WINDOW MARK - SEE DOOR AND WINDOW SCHEDULE SHEETXKey Plan3rd Floor2AUNIT2BUNIT2CUNIT2DUNIT2EUNIT2FUNITN1A4.111A4.122A4.021620 84th Ave. S.Ste. 200Kent, WA 98032(253) 468-7696www.ihbarchitects.comHF, NSThe drawings and plans set forth onthis set as instrument of service are,and shall remain, the property of IHBArchitects. Use of this drawing islimited to a specified project forpersons named hereon. And for aconstruction of one building. Anyuse or reuse of said drawings isstrictly prohibited without writtenpermission of IHB Architectsdrawn by:May 20, 2019date:-job No:IHBreviewed by:revisions:SUNRIDGE TOWNHOMES II 1222XX SE PERTOVITSKY RD RENTON, WA 98058 PARCEL NO: 0739000050 2A4.0 SOUTH - WEST SIDE ELEVATION PLANLeft Elevation - West SideSCALE: 1/4" = 1'-0"Front Elevation - South SideSCALE: 1/4" = 1'-0"12RECEIVED02/10/2020 mherreraPLANNING DIVISIONDocuSign Envelope ID: 6FEDE754-AC7F-4A9A-847E-EDB66D55B606 BT.O.S./ T.O.F0'-0"TOP PL. 8'-238"T.O. FL.9'-3"TOP PL.26'-838"TOP PL. 17'-538"T.O. FL.18'-6"34'-4"LOW ROOF36'-10"HIGH ROOF36'-4"MID ROOFJHGFEDCAEEEEEEEEBEBBEESection Keyed NotesNLRFOUNDATION WALL - SEE STRUCTURAL DETAILSRBFNDBMBEAM PER FRAMING PLANSSF1-HOUR FLOOR / CEILING ASSEMBLY (GA FILE # FC 5407):34" OSB T. & G. FLOORING, GLUE TO FLOOR JOISTS INADDITION TO NAILINGBCI JOISTS (OR EQUAL) PER FRAMING PLAN(2) 58" TYPE "X" GYP. BOARD(ATTACH PER GA FILE)PROVIDE 2x GYP./PLY NAILERS WHERE REQ'DRIM BOARD PER FRAMING PLANSF2DECK ASSEMBLY (GA FILE # FC 5420):WATERPROOF DECK COATING (TYP.)CONTRACTOR TO USE APPROVED ASSEMBLY AND INSTALLPER MANUF. SPECS34" PLYWOOD UNDERLAYMENT34" T. & G. SUBFLOOR2x JOISTS PER FRAMING PLANR30 BATT INSULATION6 MIL VAPOR BARRIER(2) 58" TYPE 'X' GYP. BOARDR-30 FLOOR INSULATIONR30RF1-HOUR CLASS A ROOF ASSEMBLY (GA FILE # RC 2602):FIBERGLASS/ASPHALT SHINGLES CLASS A5" EXPOSURE15# ROOFING FELT12" PLYWOOD ROOF SHEATHING OR OSBPRE-MANUFACTURED TRUSSES (SEE ROOF FRAMING)R-49 BATT INSULATION6 MIL VAPOR BARRIER(2) 58" TYPE "X" GYPSUM BOARD CEILING(ATTACH PER GA FILE)SLSLAB ON GRADE - SEE FOUNDATION PLAN* Refer to sheet A-0.1 forFire Rated Assemblies***T.O.S./ T.O.F0'-0"TOP PL. 8'-238"T.O. FL.9'-3"TOP PL.26'-838"TOP PL. 17'-538"T.O. FL.18'-6"34'-4"LOW ROOF36'-10"HIGH ROOF36'-4"MID ROOFCC512346789EEEEBBBBBEEElevation General Notes1.ALL STONE VENEER, PLASTER, WOOD SIDING, TRIMS,FLASHINGS, ETC. TO BE INSTALLED PER MANUF.SPECIFICATIONS.2.FOR ROOF VENT & GUTTER PLAN REFER TO ROOFPLAN3.FOR MORE ELEVATION DATUM MARKS REFER TOBUILDING AND WALL SECTIONS4.REFER TO ELEC. & MECH. PLANS FOR EXTERIORLIGHT FIXTURE LOCATIONS5. WINDOW MARK - SEE DOOR AND WINDOW SCHEDULE SHEETXKey Plan3rd Floor2AUNIT2BUNIT2CUNIT2DUNIT2EUNIT2FUNITN1A4.011A4.022A4.121620 84th Ave. S.Ste. 200Kent, WA 98032(253) 468-7696www.ihbarchitects.comHF, NSThe drawings and plans set forth onthis set as instrument of service are,and shall remain, the property of IHBArchitects. Use of this drawing islimited to a specified project forpersons named hereon. And for aconstruction of one building. Anyuse or reuse of said drawings isstrictly prohibited without writtenpermission of IHB Architectsdrawn by:May 20, 2019date:-job No:IHBreviewed by:revisions:SUNRIDGE TOWNHOMES II 1222XX SE PERTOVITSKY RD RENTON, WA 98058 PARCEL NO: 0739000050 2A4.1 NORTH-EAST SIDE ELEVATION PLANEast ElevationSCALE: 1/4" = 1'-0"North ElevationSCALE: 1/4" = 1'-0"12RECEIVED02/10/2020 mherreraPLANNING DIVISIONDocuSign Envelope ID: 6FEDE754-AC7F-4A9A-847E-EDB66D55B606