HomeMy WebLinkAboutMFP20001985.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP20001985
IVR Number: 20001985
Permit Information
Permit Name: Comcast Cable Franchise Permit
Address/Location:05/11/2020Application Date:7225500460Parcel Number: 711 N 4TH ST
Permit Type:05/20/2020Issue Date:Franchise
Permit Work Class:05/20/2021Expiration Date:Minor Utility
Job Number: 671210Franchise Type:Cable
Description: REVISION: begin @ pole SW of 803's property. perform 2 open cuts in the ROW and bore 40' under Williams Ave N,
bore 5' then bore 6' and continue boring 10' to place a 9" flush mount carson box. Pothole all existing utilities.
Restoration per City of Renton standards.
Bore 61' and open cut in ROW and place 2" PVC. Begin at pole sw of 803's property. open cut 3'X3' then bore 40'
under Williams Ave N, bore 5' then bore 6' under sidewalk and continue boring 10' to place a 9" flush mount carson
box. Pothole all existing utilities.
APPROVED WITH COMMENTS OR REDLINES
Contacts
Name Address PhoneTypeBilling
Fahm Saelee
Prince Telecom
Applicant
Rhonda Resnik
Comcast
410 Valley Ave NW, Suite 12, Bldg C
Puyallup, WA 98371
B: (253) 864-4246Contact
Tom Donnelly
Comcast Business Communications
1701 Jfk Blvd, 32nd Floor
Philadelphia, PA 19103
B: (215) 286-7347
C: (215) 286-7557
Contact
Akisha Brown
Prince Telecom Inc
551A Mews Dr
New Castle, DE 19720
B: (302) 482-8893
C: (302) 482-8892
Contractor
Business License Number: 29850Electrical Contractor: PRINCTL834BF
Construction Contractor: PRINCTL862PS
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Laurie Dietz
Comcast - Billing
1701 John F. Kennedy Blvd.
Philadelphia, PA 19103
H: (425) 741-5733Specialized
Billing
X
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
POTHOLE ALL EXISTING UTILITIES RESTORATION PER CITY OF RENTON STANDARDS
Scott Warlick 7/14/2020
Scott Warlick CED 7/14/2020
MFP20001985
MFP20001985POTHOLE ALL EXISTING UTILITIESRESTORATION PER CITY OF RENTON STANDARDS
NORTH
NOT TO SCALE
KENNY"S TRAFFIC ZONE PLANS
Kenny StertzLongview , Wa
traficplayr@aol.com
TCS # 5663Willams Ave NN 4th St
cones -
Pole -
Spotter/Flagger711803
<6'><10'>sidewalkRoad bore
SWBplanter stripcarsonset <5'><40'>
6'x2'Open cut
ONE WAY
ONE WAYWillams Ave NONE WAY
ROADWORKAHEADW20-1
200'
A
NOTES:
-Sidewalk shall remain open
-Spotter/Flagger will be onsite to help any
Pedestrians get pass the work area
Prince telecom
telecommunications
installation
Fahm Salee
253-891-2899
JOB # CSG671210ROADWORKAHEADW20-1W20-5AB100'100'LEFT LANECLOSEDAHEAD13'x4'Open cut
SIDEWALKCLOSED
R9-9
SIDEWALK CLOSEDAHEAD
CROSS HERE
SIDEWALK CLOSEDAHEAD
CROSS HERE R9-11SIDEWALKCLOSED
R9-9SIDEWALK CLOSEDAHEADCROSS HERESIDEWALK CLOSEDAHEADCROSS HERER9-11SIDEWALKCLOSEDR9-9N 3rd St
www.invarion.com