HomeMy WebLinkAboutRentonApronA_SEPA_Ecy_Comments_Response.pdfRenton Apron A SEPA Comments from Ecology dated June 30, 2020 The report Ecology attached to their SEPA comments was from the 2016 A9/A10 Construction Stormwater General Permit Application. This location is about 100 yards north and cross gradient from this project. That data is also from 2016 and recent monitoring data shows much lower levels. This Ecology reviewer did not have the recent site specific data. Two groundwater monitoring wells were installed at the project location and groundwater sampled by Galloway Environmental at April/May 2020. VOC results were either ND (Non-Detect) or ā€œJā€ flagged by the lab. A ā€œJā€ flag means estimated concentration value detected below the reporting limit. Vinyl chloride was ND. TPH was also ND. Metals were within typical background levels. These levels typically do not warrant WAC 296-843 requirements. However, the contractor will evaluate and determine the health & safety requirements for their workers. Soil will be direct shipped to Waste Management for disposal at subtitle D landfill. Groundwater from dewatering will be discharged to sanitary sewer under a KCDNR Discharge Authorization and will pass through settling tanks prior to discharge. No planned discharge to surface water. Construction impacts are not considered to be an issue due to distance from the Ecology referenced area and site specific sampling data. As part of Due Diligence, all known information regarding the specific project area is provided to the contractors.