Loading...
HomeMy WebLinkAboutD_SR_24th_Street_Short_Plat_LUA19-000062 (Revised)DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Project Location Map SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits A. AMENDED ADMINISTRATIVE REPORT & DECISION (NOTE: ALL CHANGES ARE SHOWN IN STRIKE OUT AND UNDERLINE) Decision: APPROVED APPROVED SUBJECT TO CONDITIONS DENIED Amended Report Date: July 20, 2020 Project File Number: PR19-000131 Project Name: 24th Street Short Plat Land Use File Number: LUA19-000062,SH-P, MOD Project Manager: Angelea Weihs, Associate Planner Owner/Applicant: Tuscany Construction, LLC, PO Box 6127, Bellevue, WA 98008 Contact: Cliff Williams, Development Management Engineers, LLC, 5326 SW Manning St, Seattle, WA 98116 Project Location: 4709 NE 24th Street Project Summary: The applicant is requesting approval of a Preliminary Short Plat and a Street Modification for the proposed subdivision of an existing 23,770 square foot (0.55 acre) lot, zoned Residential-4 (R-4), into two lots. The project site is located on the southeast corner of Duvall Ave NE and NE 24th Street, at 4709 NE 24th Street (parcel number 0323059245). The proposed residential density is 4.45 dwelling units per net acre. One single-family residence is presently on the property and is proposed to be retained. The proposed residential lot sizes are 10,270.1 SF for Lot 1, and 9,271.1 SF for Lot 2. Access to the new lots is proposed via new residential curb cuts off of NE 24th Street. The proposal includes 26.5 feet of public right-of-way dedication and frontage improvements along NE 24th street. The applicant proposes to retain one of the two existing significant trees on-site. No critical areas are mapped on the project site. Site Area: 23,770 square feet (0.55 acres) DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 2 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits B. EXHIBITS: Exhibit 1: Administrative Decision Exhibit 2: Neighborhood Detail Map Exhibit 3: Preliminary Short Plat Map Exhibit 4: Existing Conditions (Topography Map) Exhibit 5: Preliminary Grading, Drainage, and Utility Plan Exhibit 6: Preliminary Landscape and Tree Retention Plan Exhibit 7: Arborist Report prepared by Jeff Varley, dated May 6, 2018 Exhibit 8: Preliminary Technical Information Report prepared by Core Design, dated March 15, 2019 Exhibit 9: Geotechnical Report prepared by Cobalt Geosciences, revised March 26, 2019 Exhibit 10: Project Narrative Exhibit 11: Street Modification and Waiver Request Exhibit 12: Street Tree Elimination Request Exhibit 13: Public Comment Letter and Staff Correspondence Exhibit 14: Advisory Notes Exhibit 15: Safety Hazard Created by Land-Use Condition of Approval Staff Letter, Dated April 22, 2020 C. GENERAL INFORMATION: 1. Owner(s) of Record: Tuscany Construction, LLC, PO Box 6127, Bellevue, WA 98008 2. Zoning Classification: Residential-4 (R-4) 3. Comprehensive Plan Land Use Designation: Residential Low Density (LD) 4. Existing Site Use: Single-Family Residential 5. Critical Areas: NA 6. Neighborhood Characteristics: a. North: NE 24th Street; Single Family Homes; R-4 zone b. East: Single Family Homes; R-4 zone c. South: Single Family Homes; R-4 zone d. West: Duvall Ave NE; Single Family Homes; R-4 zone 7. Site Area: 23,770 square feet (0.55 acres) D. HISTORICAL/BACKGROUND: Action Land Use File No. Ordinance No. Date DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 3 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits Comprehensive Plan N/A 5758 06/22/2015 Zoning N/A 5758 06/22/2015 Merrit II Annexation N/A 5318 04/16/2008 Original Decision 24th St. SHPL N/A N/A 10/04/2019 E. PUBLIC SERVICES: 1. Existing Utilities a. Water: Water service is provided by the City of Renton. There is an existing 8-inch water main in NE 24th Street, north of the project site, that can deliver 1,500 gallons per minute (gpm). There is also an existing 12-inch water main in Duvall Avenue NE, west of the project site, that can deliver 3,200 gpm. b. Sewer: Sewer service is provided by the City of Renton. There is an existing 8-inch PVC sewer running north to south along the eastern frontage of Duvall Avenue NE, west of the project site. The main flows to a 54-inch manhole located approximately 75 feet south of the site’s northern boundary. From this manhole, the main flows west across Duvall Avenue NE. c. Surface/Storm Water: There is currently a private conveyance system along the eastern property frontage that drains to a private conveyance system in NE 24th Street. There is an existing 18-inch storm drain running south to northwest of the site, along the eastern Duvall Avenue NE flowline. There is also a 24-inch storm drain that flows from south to north in the center of Duvall Avenue NE. 2. Streets: The proposed development fronts Duvall Ave NE, which is classified as a principal arterial street. The King County Assessor’s Map shows a current right-of-way width of approximately 102 feet for Duvall Ave NE. There is a 0.5-foot curb along both sides of the pavement and a 6-foot sidewalk along the eastern frontage. NE 24th street is a private residential street that is owned by parcel number 0323059095. 3. Fire Protection: Renton Regional Fire Authority (RRFA) F. APPLICABLE SECTIONS OF THE RENTON MUNICIPAL CODE: 1. Chapter 2 Land Use Districts a. Section 4-2-020: Purpose and Intent of Zoning Districts b. Section 4-2-060: Zoning Use Table – Uses Allowed in Zoning Designations c. Section 4-2-110: Residential Development Standards d. Section 4-2-115: Residential Design and Open Space Standards 2. Chapter 4 City-Wide Property Development Standards 3. Chapter 6 Streets and Utility Standards a. Section 4-6-060: Street Standards 4. Chapter 7 Subdivision Regulations a. Section 4-7-070: Detailed Procedures for Short Subdivision 5. Chapter 11 Definitions DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 4 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits G. APPLICABLE SECTIONS OF THE COMPREHENSIVE PLAN: 1. Land Use Element H. FINDINGS OF FACT (FOF): 1. The Planning Division of the City of Renton accepted the above master application for review on March 27, 2018, and determined the application complete on April 2, 2019. The project was later placed on hold on April 24, 2019, and taken off hold on July 3, 2019. On October 4, 2020, the City issued an approval of the 24th Street Short Plat, LUA19-000062, with conditions. The project complied with the 120-day review period. Condition number 4 of the decision required the following: The applicant shall install a cedar fence between the new public half-street (NE 24th Street) and the private street to the north. The cedar fence shall be identified on the civil construction permit application, for review and approval by the Current Planning Project Manager, prior to Civil Construction Permit issuance. The cedar fence shall be installed prior to short plat recording. On February 28, 2020, the applicant submitted an application and engineering plans for Civil Construction Permit review. Review of the Civil Construction Permit engineering plans has determined that the condition requiring construction of the fence between the existing private street and proposed 13 foot wide public street will create safety hazards that cannot be mitigated while simultaneously meeting the condition of approval. Staff has determined an Amended Decision is needed to address public saftey concurns. See additional discussion under FOF 16, Compliance with Subdivision Regulations: Streets. 2. The project site is located 4709 NE 24th Street (Exhibit 2). 3. The project site is currently developed with a single-family residence and accessory structures. The project narrative (Exhibit 10) states that the existing structures will eventually be demolished, but does not indicate when demolition is proposed; therefore, staff analysis is based on the assumption that the existing structures are proposed to be retained at this time. 4. Access to both lots 1 and 2 is proposed via a modified public half-street along the north property line of the project site. 5. The property is located within the Residential Low Density (LD) Comprehensive Plan land use designation. 6. The site is located within the Residential-4 (R-4) zoning classification. 7. There are two existing trees located on-site. The applicant is proposing to retain one of the two trees (Exhibits 6 and 7). 8. No critical areas are mapped on the project site. 9. Approximately 120 cubic yards of material would be cut on-site and approximately 115 cubic yards of fill is proposed to be brought into the site. 10. The applicant is proposing to begin construction following land use and building permit approval. 11. Staff received one public comment letter (Exhibit 13). To address public comment the following report contains analysis related to streets and access (See FOF 16). 12. Representatives from various city departments have reviewed the application materials to identify and address issues raised by the proposed development. These comments are contained in the official file, and the essence of the comments has been incorporated into the appropriate sections of this report and the Departmental Recommendation at the end of this report. DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 5 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits 13. Comprehensive Plan Compliance: The site is designated Residential Low Density (LD) on the City’s Comprehensive Plan Map. The purpose of the LD designation is to allow a variety of single-family and multi-family development types, with continuity created through the application of design guidelines, the organization of roadways, sidewalks, public spaces, and the placement of community gathering places and civic amenities. The proposal is compliant with the following Comprehensive Plan Goals and Policies if all conditions of approval are met: Compliance Comprehensive Plan Analysis  Policy L-3: Encourage infill development of single-family units as a means to meet growth targets and provide new housing.  Goal L-I: Utilize multiple strategies to accommodate residential growth, including:  Development of new single-family neighborhoods on large tracts of land outside the City Center,  Development of new multi-family and mixed-use in the City Center and in the Residential High Density and Commercial Mixed Use designations, and  Infill development on vacant and underutilized land in established neighborhoods and multi-family areas.  Goal L-BB: Maintain a high quality of life as Renton grows by ensuring that new development is designed to be functional and attractive.  Goal L-FF: Strengthen the visual identity of Renton and its Community Planning Areas and neighborhoods through quality design and development.  Policy L-48: Address privacy and quality of life for existing residents by considering scale and context in infill project design. 14. Zoning Development Standard Compliance: The site is classified Residential-4 (R-4) on the City’s Zoning Map. The R-4 designation serves as a transition between rural designation zones and higher density residential zones. It is intended as an intermediate lower density residential zone. The proposal is compliant with the following development standards, as outlined in RMC 4-2-110.A, if all conditions of approval are met: Compliance R-4 Zone Develop Standards and Analysis  Density: There is no minimum density required in the R-4 zone. The maximum density permitted is 4.0 dwelling units per net acre. Net density is calculated after the deduction of sensitive areas, areas intended for public right-of-way, and private access easements. Calculations for minimum or maximum density which result in a fraction that is one-half (0.50) or greater shall be rounded up to the nearest whole number. Those density calculations resulting in a fraction that is less than one-half (0.50) shall be rounded down to the nearest whole number. Staff Comment: Following the dedication of public right-of-way, the subject property contains 0.448 net acres. The proposed two (2) single-family residential lots on the subject property would result in 4.46 dwelling units per net acre (2/0.448 = 4.46), which rounds down to a density of 4.0 dwelling units per net acre. Therefore, the proposal is compliant with the density standards for the R-4 zone. DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 6 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits  Lot Dimensions: The minimum lot size permitted in the R-4 zone is 9,000 sq. ft. A minimum lot width of 70 feet is required (80 feet for corner lots) and a minimum lot depth of 100 feet is required. The following table identifies the proposed approximate dimensions for Lots 1 and 2: Proposed Lot Lot Size (sq. ft.) Lot Width (ft.) Lot Depth (ft.) Lot 1 10,270.1 83.47 123.45 Lot 2 9,271.1 75.2 123.45 Staff Comment: All proposed lots would comply with the minimum lot size, width and depth requirements for the R-4 zone. Compliance not yet determined Setbacks: The required setbacks in the R-4 zone are as follows: front yard is 30 feet, side yard is combined 20 feet with not less than 7.5 feet on either side, secondary front yard (applies to corner lots) is 30 feet, and the rear yard is 25 feet. Staff Comment: The lots as proposed provide adequate area for the construction of a new home in compliance with the setback requirements on proposed Lot 1. An existing single-family residence is proposed to be retained on Lot 2. The proposed front yard setback between the existing home and the new front property line is approximately 34 feet and 10 inches (34’10”). The existing rear yard setback between the existing home and the rear property line is approximately 30 feet and 7 inches (30’7”). The proposed side yard setbacks between the existing home and the side property lines is approximately 11 feet and 9 inches (11’9”) on the west side, and 22 feet and 2 inches (22’2”) on the east side. The existing home complies with all minimum required setbacks. The orientation of both Lot 1 and Lot 2 has the front yards facing the new modified public half-street, NE 24th ST. The applicant will need to demonstrate compliance with setback requirements for Lot 1 at the time of building permit review. Compliant if condition of approval are met Building Standards: The R-4 zone has a maximum building coverage of 35% and a maximum impervious surface coverage of 50%. In the R-4 zone, a maximum building height of 3 stories with a wall plate height of 32 feet is permitted. Roofs with a pitch equal to or greater than 4:12 may project an additional six (6) vertical feet from the maximum wall plate height. If the height of wall plates on a building are less than the states maximum the roof may project higher to account for the difference, yet the combined height of both features shall not exceed the combined maximums. Common rooftop features, such as chimneys, may project an additional four (4) vertical feet from the roof surface. Non-exempt vertical projections (e.g., roofs pitched less than 4:12, decks, railings, etc.) may extend up to six (6) vertical feet above the maximum wall plate height if the projection is stepped back one-and-a-half (1.5) horizontal feet from each minimum building setback line for each one (1) vertical foot above the maximum wall plate height. Wall plates supporting a primary roof surface that has only one (1) sloping plane (e.g., shed roof) may exceed the stated maximum if the average of wall plate heights is equal or less than the maximum wall plate height allowed. Staff Comment: The existing 1,688 square foot single-family home and accessory structures on Lot 2 have a total building footprint of approximately 1,994 square feet and a building coverage of 21.5 percent (1,994 sf / 9,271.1 sf = 21.5%). The provided Preliminary Grading, Drainage, and Utility Plan (Exhibit 5) does not indicate whether the DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 7 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits existing gravel driveway and existing rockery shown on the topography map (Exhibit 4) are proposed for removal. In addition, the project narrative (Exhibit 10) states that the existing structures will eventually be demolished, but does not indicate when demolition is proposed; therefore, staff analysis is based on the assumption that the existing structures are proposed to be retained at this time. Including the existing building eaves, rockery, gravel, accessory structures, and walkways, the total impervious area for proposed Lot 2 is approximately 68.5 percent (6,352 sf / 9,271.1 sf = 68.5%), which exceeds maximum impervious surface requirements for the R-4 Zone. Therefore, staff recommends as a condition of approval that the applicant submit a revised site plan at the time of civil construction permit application that demonstrates compliance with the maximum impervious surface standards of the zone for proposed Lot 2. The existing one- story, single-family structure complies with the maximum height requirements of the zone. Building height, building coverage, and impervious surface coverage for the new single-family residence on proposed Lot 1 would be verified at the time of building permit review. Compliant if conditions of approval are met Landscaping: The City’s landscape regulations (RMC 4-4-070) require a 10-foot landscape strip along all public street frontages. Additional minimum planting strip widths between the curb and sidewalk are established according to the street development standards of RMC 4-6-060. Street trees and, at a minimum, groundcover, are to be located in this area when present. Spacing standards shall be as stipulated by the Department of Community and Economic Development, provided there shall be a minimum of one street tree planted per address. Any additional undeveloped right-of- way areas shall be landscaped unless otherwise determined by the Administrator. Storm drainage facilities shall provide a landscaping strip with a minimum fifteen feet (15') of width and be located on the outside of any required fencing, unless otherwise determined through the site plan review or subdivision review process. Staff Comment: A Preliminary Landscape Plan (Exhibit 6) was submitted with the preliminary short plat application materials. The subject property fronts Duvall Ave NE to the west and NE 24th Street to the north. The applicant is requesting a waiver of frontage improvements (See FOF 18) along Duvall Ave NE, in order to maintain the existing frontage improvements that include a paved roadway width of 65-feet, a 0.5- foot curb and gutter, a 5-foot sidewalk, and landscaping between the back of the sidewalk and the western property line of the project site. No planter strip is proposed between the curb and sidewalk along Duvall Ave NE. The applicant proposes modified half-street improvements (See FOF 17) along NE 24th Street, which would include a pavement width of 13 feet, 5-foot sidewalk, 0.5-foot curb, and an 8-foot planter strip between the curb and sidewalk. The applicant submitted a request (Exhibit 11) to eliminate the required street trees within the public right-of-way (ROW) along both Duvall Ave NE and NE 24th Street. The applicant states that the existing gas main within the proposed planter strip of NE 24th Street would prevent the installation of street trees. The applicant also states that a stormwater vault is proposed within the public ROW of NE 24th Street, which would prevent tree installation within the planter strip to the north of Lot 1. However, the applicant also states in the request that the gas main will be relocated prior to installation, and that tree installation within the planter strip is possible east of the proposed vault, once the gas main is relocated. The applicant provided no justification for why street trees cannot be planted within the public ROW of Duvall Ave NE along the west property line. Therefore, staff recommends, as a condition of approval, that the DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 8 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits applicant submit a final detailed landscape plan in compliance with RMC 4-8-120D.12 at the time of Civil Construction Permit application that includes required street trees within the public ROW of Duvall Ave NE and within the planter strip of NE 24th Street, to the east of the proposed stormwater vault. The provided landscape plan includes the required 10-feet of onsite landscaping along both Duvall Ave NE and NE 24th Street. The proposed landscape strip includes a mixture a trees, shrubs, and groundcover, in compliance with tree and shrub size requirements. The project application does not indicate when the existing single family residence on Lot 2 is proposed for removal. In order to ensure that required onsite street frontage landscaping is obtained on Lot 2, staff recommends as a condition of approval that the applicant either: 1) Install the required onsite landscaping on Lot 2 prior to short plat recording, or 2) Submit for and finalize a demolition permit for the existing single family residence prior to short plat recording. Compliant if condition of approval is met Tree Retention: The City’s adopted Tree Retention and Land Clearing Regulations (4-4- 130) require the retention of 30 percent of trees in a residential development. Significant trees shall be retained in the following priority order: Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees on slopes greater than twenty percent (20%); significant trees adjacent to critical areas and their associated buffers; and significant trees over sixty feet (60') in height or greater than eighteen inches ( 18") caliper. Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; other significant native evergreen or deciduous trees; and other significant non- native trees. Priority Three: Alders and cottonwoods shall be retained when all other trees have been evaluated for retention and are not able to be retained, unless the alders and/ or cottonwoods are used as part of an approved enhancement project within a critical area or its buffer. A minimum tree density shall be maintained on each residentially zoned lot. For detached single-family development, the minimum tree density is two (2) significant trees for every five thousand (5,000) square feet. The tree density may consist of existing trees, replacement trees, trees required pursuant to RMC 4-4-070F1, Street Frontage Landscaping Required, or a combination. Staff Comment: A Preliminary Tree Retention Plan (Exhibit 6) and Arborist Report (Exhibit 7) were submitted with the project application materials. The Tree Retention Plan and Arborist Report identify a total of 2 significant, Douglas fir trees on site. Both trees are identified as healthy trees in the arborist report and are located on proposed Lot 1. One tree is located in the vicinity of the proposed new single-family residence, and is proposed for removal. The applicant is proposing to retain the other (23-caliper inch) Douglas fir tree, which complies with the minimum tree retention requirements of the R-4 zone. In addition to complying with the minimum tree retention requirements, the applicant is required to retain or plant two (2) significant trees, or gross equivalent caliper inches, per 5,000 square feet of lot area. A minimum of four (4) trees are required on Lot 1 and Lot 2 to comply with tree density requirements. The conceptual Landscape Plan demonstrates compliance for Lot 1 by showing a total of four (4) significant trees, including one Douglas fir tree to be retained and 3 proposed (2 caliper inch) Katsura DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 9 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits trees. However, the conceptual Landscape Plat does not demonstrate compliance with minimum tree density requirements for Lot 2. No trees are proposed for retention on Lot 2, and the landscape plan only shows two (2) new trees on site. Trees located in public right-of-way are not counted towards tree retention. A minimum of four (4) trees are required on Lot 2 to comply with tree density requirements, therefore, staff recommends as a condition of approval that the applicant submit a final detailed landscape plan showing two (2) additional trees on Lot 2 in order to meet the minimum tree density requirement of four (4) trees onsite. Onsite landscaping shall be installed prior to final occupancy for the individual homes and landscaping within the right-of-way shall be installed prior to short plat recording. Compliant if condition of approval is met Parking: Parking regulations require that a minimum of two parking spaces be provided for each detached dwelling. Driveway cuts are required to be a minimum of 5 feet from property lines and new driveways may be a maximum of 16 feet in width at the property line. Maximum driveway slopes shall not exceed fifteen percent (15%); provided, that driveways exceeding eight percent (8%) shall provide slotted drains at the lower end with positive drainage discharge to restrict runoff from entering the garage/residence or crossing any public sidewalk. Staff Comment: Based on the provided topography map (Exhibit 4), the existing single- family residence on Lot 2 is accessed via an existing gravel driveway. Proposed Lot 2 has adequate area to provide off-street parking for two vehicles, however, the provided Preliminary Grading, Drainage, and Utility Plan (Exhibit 5) does not indicate whether the existing gravel driveway shown on the topography map is proposed for removal. The existing gravel driveway does not comply with maximum driveway width or driveway surface requirements. Therefore, staff recommends as a condition of approval that the applicant submit a revised site plan with the civil construction permit application that demonstrates compliance with the driveway width and surface standards for Lot 2. Compliance with the parking and driveway requirements for the new single-family residence would be verified at the time of building permit review.  Fences and Retaining Walls: In any residential district, the maximum height of any fence, hedge or retaining wall shall be seventy two inches (72"). Except in the front yard and side yard along a street setback where the fence shall not exceed forty eight inches (48") in height. There shall be a minimum three-foot (3') landscaped setback at the base of retaining walls abutting public rights-of-way. Staff Comment: The Preliminary Grading and Utility Plan (Exhibit 5) provided with the project application does not identify the need for any retaining walls for construction of the short plat. The Preliminary Landscape and Tree Retention Plan (Exhibit 6) does not identify fences for the new lots. Compliance with maximum heights for future fences on individual lots would be verified at the time of final inspection for the new single-family home. 15. Design Standards: Residential Design and Open Space Standards (RMC 4-2-115) are applicable in the R-4, R-6, R-8 zone. The Standards implement policies established in the Land Use Element of the Comprehensive Plan. Compliance with Site Design Standards must be demonstrated prior to approval of DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 10 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits the subdivision. Compliance with Residential Design Standards would be verified prior to issuance of the building permit for the new single-family homes. The proposal is consistent with the following design standards, unless noted otherwise: Compliance Design Standards R-4 and Analysis N/A Lot Configuration: One of the following is required of preliminary plat applications: 1. Lot width variation of 10 feet (10’) minimum of one per four (4) abutting street- fronting lots, or 2. Minimum of four (4) lot sizes (minimum of four hundred (400) gross square feet size difference) for street-fronting lots, or 3. A front yard setback variation of at least five feet (5’) minimum for at least every four (4) abutting street fronting lots. Staff Comment: Not applicable in the R-4 zone and the application is a short plat.  Lots shall be configured to achieve both of the following: 1. The location of stormwater infiltration LID facilities is optimized, consistent with the Surface Water Design Manual. Building and property line setbacks are specified in the Surface Water Design Manual for infiltration facilities. 2. Soils with good infiltration potential for stormwater management are preserved to the maximum extent practicable as defined by the Surface Water Design Manual. Staff Comment: See FOF 19 regarding storm water requirements. Compliance not yet demonstrated Garages: If an attached garage is wider than twenty six feet (26’), at least one (1) garage door shall be recessed a minimum of four feet (4’) from the other garage door. Additionally, one of the following is required: 1. The front porch projects in front of the garage a minimum of five feet (5’), and is a minimum of twelve feet (12’) wide, or 2. The roof extends at least five feet (5') (not including eaves) beyond the front of the garage for at least the width of the garage plus the porch/stoop area, or 3. The garage is alley accessed, or 4. The garage entry does not face a public and/or private street or an access easement, or 5. The garage width represents no greater than fifty percent (50%) of the width of the front facade at ground level, or 6. The garage is detached, or 7. The garage doors contain a minimum of thirty percent (30%) glazing, architectural detailing (e.g. trim and hardware), and are recessed from the front façade a minimum of five feet (5’), and from the front porch a minimum of seven feet (7’). DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 11 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits Staff Comment: Compliance for this standard would be verified at the time of building permit review for the new single-family residence. No changes are proposed to the existing single-family structure. Compliance not yet demonstrated Primary Entry: The entry shall include a porch or stoop with a minimum depth of five feet (5') and minimum height of twelve inches (12") above grade. Exception: in cases where accessibility (ADA) is a priority, an accessible route may be taken from a front driveway. Staff Comment: Compliance for this standard would be verified at the time of building permit review for the new single-family residence. No changes are proposed to the existing single-family structure. Compliance not yet demonstrated Facade Modulation: One of the following is required: 1. An offset of at least one story that is at least ten feet (10') wide and two feet (2') in depth on facades visible from the street, or 2. At least two feet (2') offset of second story from first story on one street facing facade. Staff Comment: Compliance for this standard would be verified at the time of building permit review for the new single family residence. No changes are proposed to the existing single-family structure. Compliance not yet demonstrated Windows and Doors: Windows and doors shall constitute twenty-five percent (25%) of all facades facing street frontage or public spaces. Staff Comment: Compliance for this standard would be verified at the time of building permit review for the new single-family residence. No changes are proposed to the existing single-family structure. N/A Scale, Bulk, and Character: N/A Compliance not yet demonstrated Roofs: A variety of roof forms appropriate to the style of the home shall be used. Staff Comment: Compliance for this standard would be verified at the time of building permit review for the new single family residence. No changes are proposed to the existing single-family structure. Compliance not yet demonstrated Eaves: Both of the following are required: 1. Eaves projecting from the roof of the entire building at least twelve inches (12") with horizontal fascia or fascia gutter at least five inches (5") deep on the face of all eaves, and 2. Rakes on gable ends must extend a minimum of two inches (2") from the surface of exterior siding materials. Staff Comment: Compliance for this standard would be verified at the time of building permit review for the new single-family residence. No changes are proposed to the existing single-family structure. DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 12 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits Compliance not yet demonstrated Architectural Detailing: If one siding material is used on any side of the dwelling that is two stories or greater in height, a horizontal band that measures at least eight inches (8") is required between the first and second story. Additionally, one of the following is required: 1. Three and one half inch (3 1/2") minimum trim surrounds all windows and details all doors, or 2. A combination of shutters and three and one half inches (3 1/2") minimum trim details all windows, and three and one half inches (3 1/2") minimum trim details all doors. Staff Comment: Compliance for this standard would be verified at the time of building permit review for the new single-family residence. No changes are proposed to the existing single-family structure. Compliance not yet demonstrated Materials and Color: For subdivisions and short plats, abutting homes shall be of differing color. Color palettes for all new dwellings, coded to the home elevations, shall be submitted for approval. Additionally, one of the following is required: 1. A minimum of two (2) colors is used on the home (body with different color trim is acceptable), or 2. A minimum of two (2) differing siding materials (horizontal siding and shingles, siding and masonry or masonry-like material, etc.) is used on the home. One alternative siding material must comprise a minimum of thirty percent (30%) of the street facing facade. If masonry siding is used, it shall wrap the corners no less than twenty four inches (24"). Staff Comment: Compliance for this standard would be verified at the time of building permit review for the new single-family residence. No changes are proposed to the existing single-family structure. 16. Compliance with Subdivision Regulations: RMC 4-7 Provides review criteria for the subdivisions. The proposal is consistent with the following subdivision regulations if all conditions of approval are met: Compliance Subdivision Regulations and Analysis  Access: Each lot must have access to a public street or road. Access may be by a shared driveway per the requirements of RMC 4-6-060 Street Standards. The maximum width of single loaded garage driveways shall not exceed nine feet (9') and double loaded garage driveways shall not exceed sixteen feet (16'). Staff Comment: As shown on the Preliminary Plat (Exhibit 3) each lot would have direct access to the new modified public half-street along the northern edge of the site. Compliance with the driveway regulations for the existing single family home would be verified at the time of civil construction permit review. Compliance with the driveway regulations for the proposed new single-family home would be verified at the time of building permit review. N/A Blocks: Blocks shall be deep enough to allow two (2) tiers of lots. DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 13 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits Staff Comment: Not applicable. The subdivision does not contain the shape or area to provide two tiers of lots.  Lots: The size, shape, orientation, and arrangement of the proposed lots comply with the requirements of the Subdivision Regulations and the Development Standards of the R-4 zone and allow for reasonable infill of developable land. All of the proposed lots shall meet the requirements for minimum lot size, depth, and width. Width between side lot lines at their foremost points (i.e., the points where the side lot lines intersect with the street right-of-way line) shall not be less than eighty percent (80%) of the required lot width except in the cases of (1) pipestem lots (or flag lot), which shall have a minimum width of twenty feet (20') and (2) lots on a street curve or the turning circle of cul-de-sac (radial lots), which shall be a minimum of thirty five feet (35'). No residentially zoned lot shall have a depth-to-width ratio greater than four-to-one (4:1). Pipestem lots may be permitted for new plats to achieve the minimum density within the Zoning Code when there is no other feasible alternative to achieving the minimum density. Staff Comment: The proposed lots are rectangular in shape and with front yards oriented to the new public half street. Lot size and dimensional requirements of the R- 4 zone are shown on the Preliminary Short Plat Map (Exhibit 3). The width between the side lot lines where they meet the new residential half-street is greater than eighty- percent (80%) of the required lot width. Compliant if conditions of approval are met Streets: The proposed street system shall extend and create connections between existing streets per the Street Standards outlined in RMC 4-6-060 Street Standards. Staff Comment: A Preliminary Grading, Drainage, and Utility Plan (Exhibit 5) was submitted with the project application. The existing site is a corner lot with street frontage on Duvall Ave NE to the west, and NE 24th Street to the north. The applicant submitted a street modification request with the project application for both Duvall Ave NE and NE 24th Street. The applicant is requesting a modification for Duvall Ave NE in order to maintain the existing street section. Duvall Ave NE is classified as a principal arterial street, with a current right-of-way (ROW) width of approximately 102 feet. The existing improvements on Duvall include a 0.5-foot curb along both sides of the pavement and a 6-foot sidewalk along the eastern frontage. The applicant is requesting a modification for NE 24th Street in order to conform to a modified residential access street standard, with a right-of-way width of 26.5 feet. NE 24th street is a private residential street that is owned by parcel number 0323059095. As shown in the provided Preliminary Grading, Drainage, and Utility Plan, the applicant would provide a new modified public half-street (See FOF 17) along the north property line to serve both lots within the short plat. The new modified half-street would run between the proposed development and the existing private street to the north. The proposed modified half-street improvements include a total width of 26.5-feet, with 13 feet of pavement, a 0.5-foot curb, an eight-foot planter strip, and a five-foot sidewalk. In addition, city staff has received public comment requesting that a fence be installed between the new public half-street and the private street to the north, in order to DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 14 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits prevent unpermitted vehicular access on the private street. Therefore, in order to prevent unauthorized usage of the private street, staff recommends a condition of approval that a cedar fence be installed by the applicant between the new public half- street and the private street to the north. The cedar fence shall be identified on the civil construction permit application, for review and approval by the Current Planning Project Manager, prior to Civil Construction Permit issuance. The cedar fence shall be installed prior to short plat recording. City staff received public comment (Exhibit 13) requesting that a fence be installed between the new public half-street and the private street to the north, in order to prevent unpermitted vehicular access on the private street. As stated in FOF 1, on October 4, 2020, the City issued an approval of the 24th Street Short Plat, LUA19 - 000062, with a condition requiring that the applicant install a cedar fence between the new public half-street (NE 24th Street) and the private street to the north. Review of the Civil Construction Permit engineering plans determined that the condition requiring construction of the fence between the existing private street and proposed 13-foot wide public street will create safety hazards that cannot be mitigated while simultaneously meeting the condition of approval. Development Engineering staff provided a letter identifying the safety hazards created by this condition of approval (Exhibit 15). The letter states that NE 24th Street is effectively being used as a public street and experiences regular residential street traffic, including pass-through traffic, residents, deliveries, garbage services and visitors. NE 24th Street also intersects with Duvall Ave NE, which is a principal arterial street. RMC 4-6-060F.2, Minimum Design Standards for Public Streets and Alleys, requires that “Site Access” occur a minimum of 125 feet from intersections, and in the case of a principal arterial, on a ‘case-by-case’ basis. By providing a fence between the existing private street and new public street, the intersection spacing between the through-street and site access will be effectively zero feet. Vehicles turning from Duvall Ave NE may errantly turn into the 13-foot wide paved public ROW expecting to be able to pass through on the private through-portion of NE 24th Street, with no way of being able to turn around except to use the private driveways or backing onto Duvall Ave NE. In addition, large trucks may not have the ability to use the private driveways to turn around and would be forced to back onto Duvall Ave NE, creating a hazardous situation. Vehicles simultaneously exiting both streets to access Duvall will have the potential to create conflicting turning movements while trying to access a principle arterial, increasing the chances for collisions with one another or traffic within the arterial ROW. Additionally, Renton Regional Fire Authority currently utilizes and will continue to utilize the private portion of NE 24th Street for fire access and the installation of a fence will create a barrier between the existing street and the proposed residences. As a result of these safety hazards, staff is amending this decision to eliminate the condition of approval number 4. The street modification has been reviewed by City staff and is recommended for approval. Please see the Street Modification Criteria and Analysis in FOF 17 for a complete summary of the request, staff analysis, and staff recommendation. Payment of the transportation impact fee is applicable on the construction of the single family houses at the time of application for the building permit. The 2019 transportation impact fee is $7,820.42 per new single family house. The fee in effect at the time of building permit application is applicable to this project and is payable at the time of building permit issuance. DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 15 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits  Relationship to Existing Uses: The proposed project is compatible with existing surrounding uses. Staff Comment: The proposed short plat is surrounded by existing detached single- family residences to the north, south, east, and west of the site. All surrounding properties are also located in the R-4 zone. The proposed lots are similar in size and shape to the existing surrounding development pattern in the area and would be consistent with the Comprehensive Plan and Zoning Code, which encourages residential infill development in the Residential Low Density (LD) Comprehensive Plan land use designation and R-4 zoning designations. Therefore, the proposal for new single-family homes would be compatible with the existing uses in the area. 17. Street Modification Analysis: Pursuant to Renton Municipal Code (RMC) 4-9-250D, the applicant is requesting a Modification from RMC 4-6-060F.2, Minimum Design Standards for Public Streets and Alleys, to modify the required street improvements on Duvall Ave NE and NE 24th Street (Exhibit 11). Duvall Ave NE is a Principal Arterial street with an available right-of-way (ROW) width of 102 feet. Per RMC 4-6-060, a four lane Principal Arterial Roadway requires a ROW width of 91 feet, totaling 50 feet of pavement, and street improvements. The required street improvements include an 8-foot sidewalk, 0.5- foot curb, and an 8-foot planter strip. The developer is required to provide the ROW dedication and construct the frontage improvements. However, the applicant is proposing to maintain the existing street section, which includes a paved roadway width of 65-feet, 0.5-foot curb and gutter, a 5-foot sidewalk and install landscaping between the back of sidewalk and the western property line of the property. NE 24th Street is a Residential Access road with no existing right-of-way (ROW). Per RMC 4-6-060, a two lane Residential Access Roadway requires a ROW width of 53 feet, totaling 26 feet of pavement, and street improvements. The developer is required to provide 26.5 feet of ROW dedication and construct the frontage improvements. The required street improvements include a pavement width of 20 feet, 5-foot sidewalk, 0.5-foot curb, and an 8-foot planter strip. However, the applicant is proposing an alternative street section, which would include 13-feet of paved roadway, rather than the code required 20 feet. The modified street section would yield a paved roadway width of 40-feet. The proposal is compliant with the following modification criteria, pursuant to RMC 4-9-250. Therefore, staff is recommending approval of the requested modification, as noted below: Compliance Modification Criteria and Analysis  a. Substantially implements the policy direction of the policies and objectives of the Comprehensive Plan Land Use Element and the Community Design Element and the proposed modification is the minimum adjustment necessary to implement these policies and objectives. Staff Comment: The Community Design Element has applicable policies listed under a separate section labeled, Promoting a Safe, Healthy, and Attractive Community. These policies address walkable neighborhoods, safety, and shared uses. The intent of the policies are to promote new development with walkable places that support grid and flexible grid street and pathway patterns, and are visually attractive, safe, and healthy environments. The requested street modification is consistent with these policy guidelines.  b. Will meet the objectives and safety, function, appearance, environmental protection and maintainability intended by the Code requirements, based upon sound engineering judgment. DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 16 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits Staff Comment: The City’s Public Works Transportation section and Economic Development section have reviewed Duvall Ave NE and the surrounding area and have determined that the modified principal arterial street section is more suitable for the portion of Duvall Ave NE adjacent to the site. The modified principal arterial street would retain the existing roadway street section, which includes a paved roadway width of approximately 66 feet, and consists of five (11-foot wide) travel lanes and two (5- foot wide) bike lanes, with a 0.5-foot wide curb on both sides. Beyond the existing curb line, the street section includes a 5-foot wide sidewalk and additional landscaping between the property line and the back of the sidewalk. No right-of-way (ROW) dedication is required from the existing ROW. City staff agree that the modified frontage improvements along Duvall Ave NE will meet the transportation needs of the surrounding area and maintain the objectives of function, safety and appearance, as required by code. The City’s Public Works Transportation section and Economic Development section have also reviewed NE 24th St and the surrounding area and have determined that a modified Residential street section is more suitable for the portion of NE 24th St adjacent to the site. The modified residential street standard has a right-of-way width of 52 feet. The existing paved roadway width is 24 feet, consisting of two 12-foot wide travel lanes. The ROW dedication will be 26.5 feet from the northern property line along NE 24th St. From the current north property line, the 26.5 feet of dedication will provide 13 feet of pavement, a 0.5-foot curb, an eight-foot planter strip, and a five-foot sidewalk. City staff agree that the modified frontage improvements along NE 24th Street will meet the transportation needs of the surrounding area and maintain the objectives of function, safety and appearance, as required by code.  c. Will not be injurious to other property(ies) in the vicinity. Staff Comment: The existing pavement width and existing pedestrian sidewalks along Duvall Ave NE provide for safe vehicular and pedestrian travel. In addition, the proposed modified half-street improvements along NE 24th Street also provide for safe vehicular and pedestrian travel. There are no identified adverse impacts to other properties from the requested modification.  d. Conforms to the intent and purpose of the Code. Staff Comment: See comments under criterion ‘b’.  e. Can be shown to be justified and required for the use and situation intended; and Staff Comment: See comments under criterion ‘b’.  f. Will not create adverse impacts to other property(ies) in the vicinity. Staff Comment: The modification would not create adverse impacts to other properties in the vicinity. See also comments above under criterion ‘c’. 18. Availability and Impact on Public Services: Compliance Availability and Impact on Public Services Analysis  Police and Fire: Police and Fire Prevention staff indicates that sufficient resources exist to furnish services to the proposed development; subject to the condition that the applicant provides Code required improvements and fees. The 2019 Fire Impact Fees are DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 17 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits $829.77 per new single-family residence. The fee in effect at the time of building permit application is applicable to this project and is payable at the time of building permit issuance. Compliant if conditions of approval are met Schools: It is anticipated that the Renton School District can accommodate any additional students generated by this proposal at the following schools: Sierra Heights Elementary (bus located 0.19 miles from the subject site), Risdon Middle School (bus located 0.19 miles from the subject site), and Hazen High School (bus located 0.13 miles from the subject site). Students from the proposed development would be bussed to all three schools. The proposed project includes the installation of frontage improvements along NE 24th Street. Existing frontage improvements, including sidewalks, exist along Duvall Ave NE. RCW 58.17.110(2) provides that no subdivision be approved without making a written finding of adequate provision made for safe walking conditions for students who walk to and from school, and to and from the bus stop. The bus stop for Hazen High is located approximately 0.13 miles from the project site on the east side of Duvall Ave NE and NE 23rd Street. Students would walk south along the east shoulder of Duvall Ave NE to NE 23rd Street where the bus stop is located. The existing sidewalk would provide a safe walking route for students to walk to the bus stop. The nearest bus stop for both Sierra Heights Elementary and Risdon Middle School is located approximately 0.19 miles from the project site on the northwest corner of Graham Ave NE and NE 23rd Street. The proposed project includes the installation of frontage improvements along the property frontage on NE 24th street; however, the remainder of the route to the bus stop for the elementary and middle school is primarily without sidewalks. The walking route to the assigned Sierra Elementary and Risdon Middle School bus stop may need improvements to establish a safe walking route. Therefore, staff recommends, as a condition of approval, that the applicant provide a safe route to school plan, for review and approval by the Current Planning Project Manager, prior to construction permit issuance. A School Impact Fee would be required in order to mitigate the proposal’s potential impacts to the Renton School District. The 2019 School Impact Fee is $6,877.00 per new single-family residence. The fee in effect at the time of building permit application is applicable to this project and is payable at the time of building permit issuance.  Parks: A Park Impact Fee would be required for the future houses. The 2019 Parks Impact Fee is $3,945.70 per new single-family residence. The fee in effect at the time of building permit application is applicable to this project and is payable at the time of building permit issuance.  Storm Water: An adequate drainage system shall be provided for the proper drainage of all surface water. Staff Comment: A Preliminary Technical Information Report (TIR; Exhibit 6), dated March 15, 2019, prepared by Core Design, was submitted with the short plat application materials. Based on the City of Renton’s flow control map, the site falls under Flow Control Duration Standards (Forested Conditions) and is located within the May Creek Drainage basin. The development is subject to Full Drainage Review in accordance with the 2017 Renton Surface Water Design Manual (RSWDM). All nine core requirements and the six special requirements have been discussed in the TIR. DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 18 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits The applicant is proposing to install a stormwater detention vault within the public right- of-way along the north side of their property. The Storm water vault has been sized assuming infiltration credits for the onsite BMP’s. The development is also proposing to connect into the existing pipe system within the Duvall Ave NE located on the west end of the property. The system will need to be sized in accordance with the 2017 RSWDM. A Geotechnical Report, dated March 28th, 2019, completed by Cobalt Geosciences, for the site has been provided. The submitted report describes the existing soils to contain very fine-grained silt deposits. The Geotechnical report mentions that infiltration is feasible on lot 2 due the types of soils that are located onsite. Stormwater system development charges (SDCs) for each new lot would apply. The 2019 stormwater SDC is $1,800.00 per lot. SDCs are due at the time of civil construction permit issuance.  Water: Water service is provided by City of Renton. The project site is within the City of Renton’s Highlands service area in the 565’ hydraulic pressure zone. There is an existing 8-inch City water main located in NE 24th Street, which can deliver approximately 1,500 gallons per minute (gpm). There is also an existing 12-inch water main in Duvall Avenue NE that can deliver 3,200 gpm. The fire flow requirement for a single family home is 1,000 gpm minimum for dwellings up to 3,600 square feet (including garage and basements). If the dwelling exceeds 3,600 square feet, a minimum of 1,500 gpm fire flow would be required. A minimum of one fire hydrant is required within 300 feet of the proposed building and two hydrants if the fire flow goes up to 1,500 gpm. The existing fire hydrants appear to meet minimum requirements. The development is subject to a water system development charge (SDC) fee. The SDC fee for water is based on the size of the new domestic water to serve the project. The 2019 water fee for a lot with a ¾-inch or 1-inch water meter is $4,050.00 per meter. Each lot shall have a separate meter.  Sanitary Sewer: Sewer service is provided by the City of Renton. There is an existing 8-inch PVC sewer running north to south along the eastern frontage of Duvall Avenue NE, west of the project site. The main flows to a 54-inch manhole located approximately 75 feet south of the site’s northern boundary. From this manhole, the main flows west across Duvall Avenue NE. The development is subject to a wastewater system development charge (SDC) fee. SDC fee for sewer is based on the size of the new domestic water to serve the project. The 2019 sewer fee for a lot with a ¾-inch or 1-inch water meter is $3,100.00 per lot. SDC fees are due at the time of civil construction permit issuance. I. CONCLUSIONS: 1. The subject site is located in the Residential Low Density (LD) Comprehensive Plan designation and complies with the goals and policies established with this designation, see FOF 13. 2. The subject site is located in the Residential-4 (R-4) zoning designation and complies with the zoning and development standards established with this designation provided the applicant complies with City Code and conditions of approval, see FOF 14. 3. The proposed short plat complies with the Residential Design and Open Space Standards provided the applicant complies with City Code and conditions of approval, see FOF 15. DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 19 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits 4. The proposed short plat complies with the subdivision regulations as established by City Code and state law provided the applicant complies with all advisory notes and conditions of approval, see FOF 16. 5. The proposed short plat complies with the street standards as established by City Code and the modification request supported by staff, provided the project complies with all advisory notes and conditions of approval contained herein, see FOF 16 and 17. 6. There are safe walking routes to schools or the bus stops provided the applicant complies with all conditions of approval, see FOF 18. 7. There are adequate public services and facilities to accommodate the proposed short plat, see FOF 18. 8. In order to ensure public health and safety the City is issuing an Amended Administrative Decision on the subject short plat. This Amended Decision will take precedence over the original decision issued on x date. J. AMENDED DECISION: The 24th Street Short Plat and Street Modification, File No. LUA19-000062,SH-P, MOD, as depicted in Exhibit 3, is approved and is subject to the following modified conditions: 1. The applicant shall submit a final detailed landscape plan in compliance with RMC 4-8-120D.12 at the time of Civil Construction Permit application that includes the following: a. Required street trees within the public ROW of Duvall Ave NE, and within the planter strip of NE 24th Street, to the east of the proposed stormwater vault; and b. Two (2) additional trees on Lot 2 in order to meet the minimum tree density requirement of four (4) trees onsite. 2. The applicant shall either: 1) Install the required onsite landscaping on Lot 2 prior to short plat recording, or, 2) Submit for and finalize a demolition permit for the existing single-family residence prior to short plat recording. 3. The applicant shall submit a revised site plan with the civil construction permit application that demonstrates compliance with the driveway width and surface standards for Lot 2. 4. The applicant shall install a cedar fence between the new public half-street (NE 24th Street) and the private street to the north. The cedar fence shall be identified on the civil construction permit application, for review and approval by the Current Planning Project Manager, prior to Civil Construction Permit issuance. The cedar fence shall be installed prior to short plat recording. 5. The applicant shall provide a safe route to school plan for review and approval by the Current Planning Project Manager prior to construction permit issuance. DATE OF DECISION ON LAND USE ACTION: SIGNATURE: For Jennifer Henning, Planning Director Date TRANSMITTED on July 20, 2020 to the Owner/Applicant/Contact: Owner: Applicant/Contact: Tuscany Construction, LLC, Cliff Williams, DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 7/20/2020 | 3:57 PM PDT City of Renton Department of Community & Economic Development 24th Street Short Plat Amended Administrative Report & Decision LUA19-000062,SH-P, MOD, MOD, MOD Report of July 20, 2020 Page 20 of 20 SR_24th Street_Short_Plat_LUA19-000062 (Revised) jc edits PO Box 6127 Bellevue, WA 98008 Development Management Engineers, LLC, 5326 SW Manning St, Seattle, WA 98116 TRANSMITTED on July 20, 2020 to the Parties of Record: James Harvey McDowell 2501 Duvall Street NE Renton, WA 98059 Elshan Aliyev 4730 NE 24th Street Renton, WA 98059 TRANSMITTED on July 20, 2020 to the following: Jennifer Henning, Interim CED Administrator Brianne Bannwarth, Development Engineering Manager Amanda Askren, Property Services Rick Marshall, Fire Marshal K. LAND USE ACTION APPEALS, REQUEST FOR RECONSIDERATION, & EXPIRATION: The administrative land use decision will become final if the decision is not appealed within 14 days of the decision date. APPEAL: This administrative land use decision will become final if not appealed in writing to the Hearing Examiner on or before 5:00 PM on August 3, 2020. An appeal of the decision must be filed within the 14-day appeal period (RCW 43.21.C.075(3); WAC 197-11-680), together with the required fee to the Hearing Examiner, City of Renton, 1055 South Grady Way, Renton, WA 98057. RMC 4-8-110.B governs appeals to the Hearing Examiner and additional information regarding the appeal process may be obtained from the City Clerk’s Office, (425) 430-6510. Due to Governor Jay Inslee’s Proclamation 20-25 (“Stay Home, Stay Healthy”), the City Clerk’s Office is working remotely. For that reason, appeals must be submitted electronically to the City Clerk at cityclerk@rentonwa.gov. The appeal fee, normally due at the time an appeal is submitted, will be collected at a future date. Appeals to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov. If the situation changes such that the City Clerk’s Office is open when you file your appeal, you have the option of filing the appeal in person. EXPIRATION: The administrative short plat decision will expire five (5) years from the date of decision. A single one (1) year extension may be requested pursuant to RMC 4-7-070.M. RECONSIDERATION: Within 14 days of the decision date, any party may request that the decision be reopened by the approval body. The approval body may modify his decision if material evidence not readily discoverable prior to the original decision is found or if he finds there was misrepresentation of fact. After review of the reconsideration request, if the approval body finds sufficient evidence to amend the original decision, there will be no further extension of the appeal period. Any person wishing to take further action must file a formal appeal within the 14-day appeal time frame. THE APPEARANCE OF FAIRNESS DOCTRINE: provides that no ex parte (private one-on-one) communications may occur concerning the land use decision. The Doctrine applies not only to the initial decision, but to Appeals to the Hearing Examiner as well. All communications after the decision/approval date must be made in writing through the Hearing Examiner. All communications are public record and this permits all interested parties to know the contents of the communication and would allow them to openly rebut the evidence in writing. Any violation of this doctrine could result in the invalidation of the appeal by the Court. DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0 CITY OF RENTON DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT ADMINISTRATIVE REPORT & DECISION EXHIBITS Project Name: 24th Street Short Plat Land Use File Number: LUA19-000062,SH-P, MOD Date of Report July 20, 2020 Staff Contact Angelea Weihs Associate Planner Project Contact/Applicant Cliff Williams Development Management Engineers, LLC 5326 SW Manning St, Seattle, WA 98116 Project Location 4709 NE 24th Street The following exhibits are included with the ERC report: Exhibit 1: Administrative Decision Exhibit 2: Neighborhood Detail Map Exhibit 3: Preliminary Short Plat Map Exhibit 4: Existing Conditions (Topography Map) Exhibit 5: Preliminary Grading, Drainage, and Utility Plan Exhibit 6: Preliminary Landscape and Tree Retention Plan Exhibit 7: Arborist Report prepared by Jeff Varley, dated May 6, 2018 Exhibit 8: Preliminary Technical Information Report prepared by Core Design, dated March 15, 2019 Exhibit 9: Geotechnical Report prepared by Cobalt Geosciences, revised March 26, 2019 Exhibit 10: Project Narrative Exhibit 11: Street Modification and Waiver Request Exhibit 12: Street Tree Elimination Request Exhibit 13: Public Comment Letter and Staff Correspondence Exhibit 14: Advisory Notes Exhibit 15: Safety Hazard Created by Land-Use Condition of Approval Staff Letter, Dated April 22, 2020 DocuSign Envelope ID: 3C3C1BE1-F093-4284-8235-BCB72DA597E0