HomeMy WebLinkAboutS-3939076 GAGE BANDS, @ 14" 2 3/8" O.D. LINE POST MAX. @ 10' O.C. 9 GAGE WIRE CLIPS, @ 24" x �/o 0\,\l :.. \ 1-2/3" O.D. INTERMEDIATE 1 5/8" O.D. TOP AND BRACE RAIL � � \ � � /��\ BOTTOM RAIL .D ;. FENCE POST FOUNDATION � � 10' MAX. 10' MAX. ENSURE THE INSTALLED GATE ELEVATION PERMITS SWING OPENING PER PLAN AND PER EXISTING PAVEMENT SLOPE. 4" O.D. GATE POST ROD MUST SIT 4"-6" IN CONCRETE CHAIN -LINK FENCEr206� NOT TO SCALE CO2 VEHICLE ACCESS GATE GATE POST FOUNDATION CENTER GATE POST FOUNDATION. MIN. DEPTH 18" CHAIN -LINK DOUBLE SWING GATE DETAIL zoe NOT TO SCALE CO2 4" 0. D 3/8" TIE ROD, TYP. CMU BUILDING ALL -MOUNT (FLAT BACK) ATE LATCH WITH PADLOCK ;RSONNEL ACCESS GATE UNDATION PERSONNEL ACCESS GATE DETAIL NOT TO SCALE �03 ALL CHAIN LINK FENCE 2-718 O.D. END POST SHALL BE BLACK VINYL COATED MIN. 3 MILS DFT. FENCE POST HOLE CONCRETE: MIN. DEPTH = 48" 3/8" TIE ROD MIN. DIAMETER =18" MIN. POST EMBEDMENT = 24" JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS. USE STAPLES, WIRE RINGS, OR EQUIVALENTS TO ATTACH FABRIC TO POSTS. 6' MAX. POST SPACING MAY BE INCREASED TO 8' IF WIRE BACKING IS USED 3" WELDED SS GOOSENECK 3" SS PIPE GROUND ELEVATION 24 MIN. TRANSITION TO PVC BELOW GRADE GATE POST HOLE CONCRETE: MIN. DEPTH = 54" MIN. DIAMETER = 24" MIN. POST EMBEDMENT = 24" NOTE: FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOUR WHENEVER POSSIBLE 2"x2" BY 14 G a. WIRE OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRIC TRENCH BACKFILL TRENCH WITH NATIVE SOIL OR 3/4" -1.5" WASHED GRAVEL MINIMUM 4"x4" WOOD POSTS, STEEL TRENCH FENCE POSTS, REBAR, OR EQUIVALENT SILT FENCE 209 NOT TO SCALE C01 3" WELDED SS FLANGE 3" SS FLANGE WITH SS INSECT SCREEN BETWEEN TWO FLANGES 3 -0 2' x 2' x 0.5' THICK CONCRETE PAD W/ WIRE MESH REINFORCEMENT 3" WELDED SS BEND 3" SS PIPE WET WELL PASSIVE VENT DETAILSK021 2 NOT TO SCALE CO2 An 2"x2" BY 14 G a. WIRE OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED z N 6' TALL TEMPORARY CHAIN -LINK FENCE PANEL, TYP. 'o 10/\ o 10/ o 10/0'\1 K'/,o 10/0'\ Kr/,o 000/'\ K'/,o 10 � STABILIZER BRACKET, TYP. GROUND SURFACE TEMPORARY NOT CHAIN=LINK FENCE TO SCALE ro7 PIPE TRENCH TRENCH WIDTH PER WSDOT SS 2-09.4 ZAVEL BACKFILL FOR PIPE ZONE :DDING PER SPECIFICATIONS PIPE ZONE BEDDING 210 NOT TO SCALE C05 vim- vvni�iv�i niVnivi VAULT OR APPROVED EQUAL OlLmWATER SEPARATOR SECTION VIEW 11111 2.......... 1111,1111111 13 NOT TO SCALE �CJ02 Q'I D\/r` TCC PER N, TYP. 3�9r 373.71' A co co 441 'e� �' w O I ULo zco V C"' N zo �� W d � z u o jo ZC-) J W c'i W C-4 =�O� :mN cn J a uj 0 J c� 0 o > U cn rvoo Z 0 U O Lu J rvoo - w U- 0 z 0 W Lu Lu J 0 U rn rn � o w o CV CV . Cfl CV 0 Q Q W co co CV U- 0 w W W z W CD WLu Lu cc ml of z SCALE: SHOWN Oil 211 DRAWING IS FULL SCALE WHEN BAR MEASURES 2" DWG NO.: SHEET NO.: C06 7 34