GEOTECHNICAL PARAMETERS:
MINIMUM FROST DEPTH
MAXIMUM NET BEARING
AT -REST LATERAL EARTH PRESSURE
SOILS REPORT REFERENCE
OTHER LOADING PARAMETERS:
WIND LOAD
SNOW LOAD
OTHER DESIGN VALUES USED:
OCCUPANCY CATEGORY
CONCRETE
CMU
STEEL
TIMBER
i 111C i nnnc.
muur
12"
4,000 PSF STATIC
56 PSF
"ENGINEERING GEOLOGY REPORT" PREPARED
BY RH2 ENGINEERING
110 MPH, EXPOSURE C
25 PSF
ESSENTIAL FACILITY
47000 PSI WITH 60,000 PSI REINFORCING
17500 PSI WITH 60,000 PSI REINFORCING
A36 FOR PLATES, A992 FOR OTHER
PER FRAME MANUFACTURER
20 PSF
CRITERIA:
ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE
DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (2015 EDITION)
SPECIAL INSPECTIONS, TESTS, AND OBSERVATIONS:
SPECIAL INSPECTIONS AND TESTS SHALL INCLUDE THE FOLLOWING. REFER TO IBC SECTION 1704
AND 1705 FOR DETAILS.
1. SPECIAL INSPECTIONS BY THE GEOTECHNICAL ENGINEER INCLUDING:
1.1. SITE EXCAVATION AND GRADING
1.2. PLACEMENT OF STRUCTURAL FILL AND SOIL COMPACTION
1.3. VERIFICATION OF SOIL -BEARING CAPACITY
2. CONCRETE PLACEMENT AT CONCRETE CONSTRUCTION: CONTINUOUS, SEE ALSO SECTION
1705.3 OF THE INTERNATIONAL BUILDING CODE.
3. REINFORCEMENT AT CONCRETE CONSTRUCTION: PERIODIC, SEE ALSO SECTION 1705.3.
4. MASONRY CONSTRUCTION, INCLUDING PLACEMENT OF MASONRY UNITS, MORTAR
REINFORCEMENT AND STRUCTURAL CONNECTIONS: PERIODIC, SEE ALSO SECTION TMS 602 /
ACI 530.1 /ASCE 6, TABLE 5.
5. GROUT PLACEMENT AT MASONRY CONSTRUCTION: CONTINUOUS, SEE ALSO SECTION TMS 602
/ ACI 530.1 / ASCE 6, TABLE 5.
6. WOOD -FRAMED LATERAL -FORCE RESISTING SYSTEM: PERIODIC, SEE ALSO SECTION 1705.10.
7. TESTING OF CONCRETE FOR SPECIFIED COMPRESSIVE STRENGTH (FC), AIR CONTENT AND
SLUMP. SEE ALSO TABLE 1705.3.
8. VERIFICATION OF SPECIFIED COMPRESSIVE STRENGTH (FM) OF MASONRY PRIOR TO
CONSTRUCTION AND EVERY 5,000 SQUARE FEET DURING CONSTRUCTION. SEE ALSO TMS 602
/ ACI 530.1 / ASCE 6, TABLE 5.
9. STRUCTURAL OBSERVATION BY REGISTERED DESIGN PROFESSIONAL IN ACCORDANCE
WITH IBC 1704.5 SHALL BE PROVIDED.
GENERAL:
LINES SHOWN ON DRAWINGS MAY BE ASSOCIATED WITH CAD MODELING AND MAY NOT
REPRESENT REQUIRED OR ALLOWED JOINTS. SEE DETAILS FOR CLARIFICATION ON REQUIRED
AND ALLOWED JOINTS.
REINFORCED CONCRETE:
1. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORDANCE
WITH ACI 315-99 AND 318-14. LAP ALL REINFORCEMENTS IN ACCORDANCE WITH THE
"REINFORCING SPLICE AND DEVELOPMENT LENGTH SCHEDULE" - SEE THIS SHEET. LAP
ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS.
2. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS
SPECIFICALLY DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER.
3. A 6" WATERSTOP SHALL BE PLACED AT ALL BELOW GRADE CONCRETE SLAB AND WALL
CONSTRUCTION JOINTS AND AS SHOWN TO PROVIDE A WATERTIGHT STRUCTURE.
4. CONCRETE PROTECTION FOR REINFORCING STEEL SHALL BE AS FOLLOWS, UNLESS
OTHERWISE NOTED:
4.1. FOOTINGS AND OTHER UNIFORMED SURFACES CAST AGAINST AND
PERMANENTLY EXPOSED TO EARTH ............................... 3"
4.2. FORMED SURFACES EXPOSED TO EARTH (WALLS BELOW GRADE),
WATER OR WEATHER (#6 BARS OR LARGER) ........................ 2"
4.3. COLUMN TIES OR SPIRALS AND BEAM STIRRUPS ...................... 2"
4.4. SLABS AND INTERIOR FACES ....................................... 2"
ABBREVIATIONS:
AL -
ALUMINUM
CHK - CHECKERED
CL -
CENTERLINE
CLR
- CLEAR
EA -EACH
E F -
EACH FACE
F B -
FLAT BAR
GALV - GALVANIZED
HORZ - HORIZONTAL
LLV
- LONG LEG VERT
O.C.
- ON CENTER
PL-
PLATE
RB -
ROUND BAR
RST
- REINF. STEEL
SST
- STAINLESS STEEL
T&B
- TOP & BOTTOM
VERT
- VERTICAL
REINFORCEMENT SPLICE AND DEVELOPMENT SCHEDULE
7
MINIMUM STRAIGHT
MINIMUM LAP
MINIMUM
DEVELOPMENT LENGTHS
SPLICE
EMBEDMENT
LENGTHS
LENGTHS
BAR
TOP BARS
OTHER BARS
TOP BARS
ALL BARS
#4
2511
19"
3311
7"
#5
3111
24"
4111
9"
#6
3 7"
2 9"
4 9"
10"
#7
54"
42"
71 "
12"
"TOP BARS" ARE HORIZONTAL BARS WITH MORE THAN 12" DEPTH OF
CONCRETE CAST BELOW THEM.
IF CLEAR CONCRETE COVER IS LESS THAN 2x THE DIAMETER OF THE
BAR OR THE CENTER -TO -CENTER SPACING IS LESS THAN (4) BAR
DIAMETERS, THEN VALUES SHALL BE INCREASED BY 43%
SIDE COVER MUST BE EQUAL TO OR GREATER THAN 2-1/2"
END COVER FOR 900 HOOKS MUST BE EQUAL TO OR GREATER THAN 2"
CMU ANCHORS FOR USE GROUTED CMU CELLS SHALL BE SIMPSON SET-XP OR EQUAL ANCHORING
ADHESIVE. CMU ANCHORS FOR USE IN UNGROUTED CMU CELL SHOULD BE AVOIDED. WHEN
UNAVOIDABLE, ANCHORS SHALL BE SIMPSON SET-XP WITH OPTI MESH ADHESIVE ANCHORING
SCREEN TUBE.
EQUIPMENT WEIGHING LESS THAN 250 LBS MAY BE ANCHORED TO CMU WALLS W/ SIMPSON TITEN-HD
HEAVY DUTY SCREW ANCHORS
WHERE SIZE IS CALLED OUT ON THE DRAWINGS, PROVIDE MINIMUM EMBEDMENT DEPTHS AS SHOWN
ON THE FOLLOWING TABLES. PROVIDE MINIMUM EDGE DISTANCES AND SPACING AS SHOWN ON THE
FOLLOWING TABLES UNLESS SPECIFICALLY DETAILED OTHERWISE.
INSTALL ANCHORS IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
NOTIFY OWNER 24 HOURS IN ADVANCE OF INSTALLATION OF ALL ANCHORS.
WHERE SIZE IS NOT CALLED OUT, ANCHOR SHALL BE SELECTED BASED ON DESIGN LOADS. IF THE
MINIMUM EDGE DISTANCE AND/OR MINIMUM SPACING CAN NOT BE ACHIEVED, REFER TO PRODUCT
INFORMATION FOR REDUCTION IN ALLOWABLE LOADS.
FORCES ARE DETERMINED BY THE FOLLOWING FORMULA: (Ps / Pt) + (Vs / Vt) =1
WHERE: Ps
= APPLIED SERVICE TENSION LOAD
Pt =
ALLOWABLE SERVICE TENSION LOAD
Vs
= APPLIED SERVICE SHEAR LOAD
Vt
= ALLOWABLE SERVICE SHEAR LOAD
THE ABOVE FORMULA IS FOR THE ALLOWABLE LOADS FOR ANCHORS SUBJECTED TO COMBINED
TENSION AND SHEAR.
GROUTED CMU ANCHORS
SIMPSON STRONG -TIE SET-XP
DIA. OF ROD
(INCHES) OR
REBAR SIZE N0.
MIN. EDGE
DISTANCE
(INCHES)
MIN.
EMBEDMENT
(INCHES)
MIN. ANCHOR
SPACING
(INCHES)
ALLOWABLE LOAD BASED ON
BOND STRENGTH (POUNDS)
TENSION
SHEAR
3/8
12
3-3/8
(1) PER CELL
17490
17145
1/2
12
4-1/2
(1) PER CELL
17825
17350
5/8
12
5-5/8
(1) PER CELL
1,895
1,350
3/4
12
6-1/2
(1) PER CELL
1,895
1,350
#3
12
3-3/8
(1) PER CELL
17395
17460
#4
12
4-1/2
(1) PER CELL
1,835
1,505
#5
12
5-5/8
(1) PER CELL
2,185
1,505
UNGROUTED CMU ANCHORS
SIMPSON STRONG -TIE SET-XP WITH ANCHORING SCREEN TUBE
DIA. OF ROD
(INCHES) OR
REBAR SIZE N0.
MIN. EDGE
DISTANCE
(INCHES)
MIN.
EMBEDMENT
(INCHES)
MIN. ANCHOR
SPACING
(INCHES)
1 ALLOWABLE LOAD BASED ON
BOND STRENGTH (POUNDS)
TENSION
SHEAR
3/8
12
3
(1) PER CELL
280
265
1/2
12
3
(1) PER CELL
280
265
5/8
12
3
(1) PER CELL
280
265
3/4
12
3
(1) PER CELL
280
265
#3
12
3
(1) PER CELL
280
265
#4
12
3
(1) PER CELL
280
265
#5
12
3
(1) PER CELL
280
265
CMU ANCHOR r301
so
CONCRETE ANCHORS SHALL BE EITHER HILTI HIT -RE 50043 INJECTABLE MORTAR, SIMPSON
STRONG -TIE SET-XP ANCHORING ADHESIVE, OR POWERS PE1000+ADHESIVE ANCHORS AS
SPECIFIED. WHERE SIZE IS CALLED OUT ON THE DRAWINGS, PROVIDE MINIMUM EMBEDMENT DEPTHS
AS SHOWN ON THE FOLLOWING TABLES. PROVIDE MINIMUM EDGE DISTANCES AND SPACING AS
SHOWN ON THE FOLLOWING TABLES UNLESS SPECIFICALLY DETAILED OTHERWISE. SPECIAL
INSPECTION REQUIRED.
INSTALL ANCHORS IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
NOTIFY OWNER 48 HOURS IN ADVANCE OF INSTALLATION OF ALL ANCHORS.
WHERE SIZE IS NOT CALLED OUT, ANCHOR SHALL BE SELECTED BASED ON DESIGN LOADS. IF THE
MINIMUM EDGE DISTANCE AND/OR MINIMUM SPACING CAN NOT BE ACHIEVED, REFER TO PRODUCT
INFORMATION FOR REDUCTION IN ALLOWABLE LOADS.
CONCRETE ANCHORS
HILTI HIT -RE 50043, SIMPSON STRONG -TIE SET-XP & POWERS PE1000+
DIA. OF ROD
(INCHES) OR
REBAR SIZE NO.
MIN. EDGE
DISTANCE
(INCHES)
MIN.
EMBEDMENT
(INCHES)
MIN. ANCHOR
SPACING
(INCHES)
ALLOWABLE LOAD BASED ON
BOND STRENGTH (POUNDS)
TENSION
SHEAR
1/2
2-1/2
2-3/4
2-1/2
1, 027
27210
5/8
3-1/8
3-1/8
3-1/8
1312
2827
3/4
3-3/4
3-1/2
3-3/4
1, 556
3, 351
7/8
4-3/8
3-1/2
4-3/8
1, 556
37351
#4
2-1/2
4-1/2
2-1/2
1, 520
37618
#5
3-1/8
5-5/8
3-1/8
1, 775
57494
#6
3-3/4
6-3/4
3-3/4
27225
77570
#7
4-3/8
7-7/8
4-3/8
27440
97428
#8
5
9
5
4520
11507
CONCRETE ANCHOR sot
NOTE: SEE ELECTRICAL DRAWINGS FORco
EQUIPMENT LOCATION AND DIMENSIONS.
�
CAST -IN -PLACE CONCRETE, ROUGHEN FLOOR
CO �, a
: �
3 MIN. BEYOND
UNDER PAD PRIOR TO POURING PAD. PROVIDE
LO
EQUIPMENT BOLTS, TYP.
#4 DOWELS, EACH
44 W1.4xW1.4 WWM AT TOP FACE WITH 1/
CLEAR COVER
CORNER AND 18" O.C., 3"
EMBEDMENT INTO FLOOR
CAST -IN -PLACE CONCRETE
p a • °' p
FLOOR, REINF. PER PLAN
x_.x_x.,x�x_x
p
p aA.
a -
a
•s o.° •• aD ;o. a p °o' °
a
a :e'
p
° o .d. a .• °• •'o'• ••a o••a °o.
.D°
CONT. CORNER BARS
TYPICAL BAR DETAILING
AT FOOTING CORNER
EQUIPMENT PAD 303
Sol
#5 @ 12" O.C., MIN. 2
4" CHAMFER, ALL
OUTER EDGES
4" UNLESS
OTHERWISE NOTED
CMU DOWELS TO MATCH
WALL VERTS. EXTEND
2'-0" INTO CMU WALL
CMU WALL
PJF, TYP. UNO
FLOOR SLAB
FOOTING e
INSULATION 4 d :b: "
° 6
#5 DOWELS @ 12 O.C.,
ALTERNATE HOOKS
_ . a Q. 24"
(3) #5
a
8" A
.p
P o °p
11-611
TYPICAL FOOTING
SPREAD FOOTING
1" = 1'-0"
0
DOOR
)/2" PJ F
EXTEND CONCRETE FLOOR
EXTERIOR SLAB
ACROSS THRESHOLD
P 10° °
° ° °
a ' a e o •aa
DA
o g
:e 4 a p
2 LAYERS OF 30#
HOLD FOOTING DOWN BUILDING PAPER
,a• : p a .
SPREAD FOOTING
°
1 ' -6"
DOOR THRESHOLD
1" = 1'-0"
K3'07
S01
co
Q, .
ago H a
o
00
0
0
z
O
CV
O
0
J
W U-
z z
W Lu
J
U
o
O CV
CV .
O CV
Q
0 0
o
c
c
z
O Lu
Cn 0
U
W
1
0
U
w
m
0
w
co
CV
0
Zco
r~ o 0
V � N
zo
� � c/)
w�
w d �
z
C�
z' o d o
W
wN �
E_ 3:N
= 0�
�i: mN
W
cc
ml
z
0
cc
Lu
0
L
of
z
SCALE: SHOWN
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
DWG NO.: SHEET NO.:
S02 9 34