HomeMy WebLinkAboutS-393911PRECAST CONCRETE VALVE VAULT � VAULT LADDER M03 DBI SALA DAVIT SLEEVE, EMBEDDED ONTO TOP OF VALVE VAULT, SEE DAVIT SLEEVE NOTES 8" Ql CLEANOUT IN TOP SLAB TO BE EQUAL TO ZURN Z1400-K 14' x 8' x 6'-6" (MINIMUM DEPTH)(INTERIOR DIMENSIONS) PRECAST CONCRETE VAULT, 814-LA OR APPROVED EQUAL Al SLOPE VAULT FLOOR AT 2% TOWARD SUMP CONCRETE VAULT BASE An T AP SUBGRADE SHALL BE INSPECTED BY LICENSED ENGINEERING GEOLOGIST OR PROFESSIONAL ENGINEER AT THE LOWEST EXCAVATED SUBGRADE ELEVATION FOLLOWING APPROVAL, 6" CRUSHED ROCK SHALL BE COMPACTED TO A FIRM AND UNYIELDING CONDITION IN THE PRESENCE OF THE GEOLOGIST OR ENGINEER, TYP. 6'-0" INTERNAL DIAMETER PRECAST CONCRETE WETWELL DBI SALA DAVIT SLEEVE, WALL MOUNTED TO SIDE OF WETWELL, SEE DAVIT SLEEVE NOTES 8'-0" INTERNAL DIAMETER PRECAST CONCRETE WET WELL WET WELL LADDER ("'G "J03 128" DIAMETER PRECAST CONCRETE WET WELL TOP WITH BOTTOM BUTT JOINT PROPOSED LIFT STATION STRUCTURAL PLAN STRUCTURAL BACKFILL SHOULD BE PLACED AT OPTIMAL MOISTURE CONTENT IN 6" LOOSE LIFTS AND COMPACTED TO A FIRM AND UNYIELDING CONDITION AT LEAST 95% OF MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST (ASTM D 1557), TYP. ASPHALT PAVEMENT AND SUBGRADE PER DWG NO. C05 COAT VAULT AND WETWELL PER SPECIFICATIONS 8'-0" INTERIOR DIAMETER PRECAST WET WELL. TOP RISER SHALL HAVE ATOP BUTT JOINT. FLYGT FIBERGLASS TOP BASIN 6'-0" INTERIOR DIAMETER PRECAST WET WELL LIFT STATION STRUCTURAL ELEVATION A" INSTALL GASKET ON TOP FACE OF TOP RISER PRIOR TO PLACING TOP SLAB ' 359.75' qu ( -355-.26 355.75' Q� GROUT FILL THE ANNULAR SPACE BETWEEN STRUCTURES ACCESS HATCH SCHEDULE NO. CLEAR OPENING NO. OF LEAVES RATING MOUNTING*GASKET SAFETY CHAIN** 4811x72" 2 H-20 BOLTS YES ODOR TIGHT 2 661lx42" 1 H-20 ANCHOR YES STANDARD ACCESS HATCH NOTES- * THE WET WELL ACCESS SHALL BE MOUNTED USING STAINLESS STEEL BOLTS AS SHOWN ON THIS PLAN. THE VALVE VAULT ACCESS HATCHES SHALL BE MOUNTED USING THE STANDARD FRAME ANCHORS THAT COME WITH THE HATCH. ** SAFETY CHAINS SHALL BE PROVIDED ON ACCESS HATCHES AS SHOWN IN DETAIL rD"� ��M 33 DAVIT SLEEVE NOTES: 1. PROVIDE CAP FOR EACH DAVIT SLEEVE. 2. CONFIRM FINAL LOCATION OF ALL DAVIT SLEEVES WITH CITY BEFORE INSTALLING. b I KUL; I UKAL UbLIUUL NOT TO SCALE SUBGRADE SHALL BE INSPECTED BY LICENSED ENGINEERING GEOLOGIST OR PROFESSIONAL ENGINEER AT THE LOWEST EXCAVATED SUBGRADE ELEVATION FOLLOWING APPROVAL, 6" CRUSHED ROCK SHALL BE COMPACTED TO A FIRM AND UNYIELDING STRUCTURE BOTTOM ELEVATION BASED ON SUBMITTALS AND CITY, Q1 MEASURE -DOWN. SURVEYED ELEVATION OF 357.85 WAS INCORRECT. CONDITION IN THE PRESENCE OF THE GEOLOGIST OR ENGINEER co ► o coo �, a 00 Lo ~' A P P. co 441 O � UC-4 zco r n� o 0 V � N zo �cx� CZ w� w d cWi) Z Z w c'i w N =nor" mN 0 Z z O Q � Z O co J am LU � LLI J � 08 LL �mm 0 am 0 J a H cm) cn LL Lu < Lu cc 00 o m � 0 z 0 0 co o U) of "' Z 0 6 o Lu J z w LL U) o � z w z � J LL, � U U) Z 0 rn rn � 0 o w CV CV ZO 0 0 0 CV CV Lu 0) 0) U) cc Q Q w W o Lu Lu 0 0 W CV ti Q LL U o WW W � SCALE: SHOWN Oil 211 DRAWING IS FULL SCALE WHEN BAR MEASURES 2" DWG NO.: SHEET NO.: S03 11 ]73�4