HomeMy WebLinkAboutS-393919ABBREVIATIONS SPDT - SINGLE POLE DOUBLE THROW SPST - SINGLE POLE, SINGLE THROW DPST DOUBLE POLE, SINGLE THROW LADDER LOGIC SYMBOL LEGEND INDICATOR LIGHT RELAY INDICATOR LIGHT RELAY o ONE -LINE DIAGRAM SYMBOLS PANELBOARDS, SWITCHES, AND EQUIPMENT LIGHTING FIXTURES/DEVICES i� - - CIRCUIT BREAKER XXX YY - CB SIZE & N0. OF POLES / SERVICE ENTRANCE, SWITCHGEAR, MOTOR CONTROL CENTER, OR � FLUORESCENT FIXTURE ET -ELECTRONIC TRIP PANELBOARD - WP WEATHER-PROOF A -AMBER G -GREEN XYZ TR -TIMED RELAY �` - g � - B -BLUE R -RED 123 CR RELAY TM -THERMAL MAGNETIC BREAKER MCP -MOTOR CIRCUIT PROTECTOR WALL/CEILING MOUNTED FIXTURE GFI - GROUND FAULT INTERRUPT P -POWER C -CLEAR W -WHITE -CONTROL • „ '� ° � b� `o�'�� �~ w SE -SERVICE ENTRANCE GFI -GROUND FAULT INTERRUPTER SURFACE MOUNTED PANELBOARD C -CONTROL J -INSTRUMENTATION FLOAT SWITCH � --EE� ��o FUSE FUSED DISCONNECT SWITCH EMERGENCY LIGHT WITH SELF PC -POWER &CONTROL CJ -CONTROL &INSTRUMENTATION CKT. -CIRCUIT LIMIT SWITCH Q LIMIT SWITCH, NORMALLY OPEN 0 FLOAT SWITCH, NORMALLY OPEN PLUG-IN CONNECTION FLUSHED MOUNTED PANELBOARD 00 CONTAINED BATTERY C.O. -CONDUIT ONLY N.L. -NIGHT LIGHT RTM RUN TIME METER AL. -ALUMINUM LIMIT SWITCH FLOAT SWITCH w NXX � ❑ FIELD CONTROL STATION WITH NEMA REQUIREMENTS. SURFACE OR PENDANT MOUNTED O FIXTURE7sOC CU. -COPPER LIMIT SWITCH, NORMALLY CLOSED FLOAT SWITCH, NORMALLY CLOSED �GP��' °�° �'�a1�, a' e MOTOR OPERATION COUNTER � ' SSRVS N1 - NEMA 1 N3R - NEMA 3R RECESSED FIXTURE O HOA HAND -OFF -AUTO SWITCH R� RUN TIME METER � 7°,� 0 01 1 q N�r� SSRVS -SOLID STATE N4 - NEMA 4 N4SS - NEMA 4 STAINLESS STEEL N4F - NEMA 4 FIBERGLASS MD MOTION DETECTOR OC OPERATION COUNTER MRIL MOTOR RUN INDICATION LIGHT TIME DELAY CONTACT TIME DELAY CONTACT, NORMALLY OPEN, � TIME TO CLOSE PUSHBUTTON Q� � PUSHBUTTON, NORMALLY CLOSED �,. � O " �L' � �, � REDUCED VOLTAGE STARTER N6 - NEMA 6 SFIL SEAL FAIL INDICATION LIGHT N12 - NEMA 12 GASKETED PC PHOTO CONTROL CELL SFTR SEAL FAIL TRIP RESET OTIL OVER TEMPERATURE LIGHT ti VARIABLE FREQUENCY DRIVE � EQUIPMENT MOUNTING STAND MOIL MOTOR OVERLOAD INDICATION LIGHT TIME DELAY CONTACT TIME DELAY CONTACT, NORMALLY CLOSED, TIME TO OPEN PUSHBUTTON � � O O PUSHBUTTON, NORMALLY OPEN U N u) �n �n Z Lo FIRE SYSTEM SYMBOLS � INDICATE TYPE BY o w w �' Z g .� OH HEAT DETECTOR MOTOR STARTER (TOT) HEATER, WATTAGE NOTED S SMOKE DETECTOR INSTRUMENT METER LETTER TIME DELAY CONTACT THERMOSTAT � � �, W Z~ W dui z z - Z Z q g x�DEVICES MOTOR STARTER W/ OPERATORV F-D]FIRE ALARM DISPATCH STROBE ALARM A -AMMETER VAR - VARMETER AH -AMPERE-HOUR VARH - VARHOUR METER OPENONTACT, NORMALLY OPEN, O TIME TIME DELAY Q • w � 0 a- z �� Z � u w C,,-) W N C D � EQUIPMENT CONNECTION PF -POWER FACTOR W -WATTMETER W a �' _ �` o _ _ A HAND -OFF -AUTO B -OPERATIONAL COUNTER ❑A FIRE ALARM AUDIBLE/VISUAL ALARM V -VOLTMETER WH - WATTHOUR METER TIME DELAY CONTACT THERMOSTAT � J_j� 3 m N N C -RUN TIME METER D -RUN LIGHT E -FAIL LIGHT m SINGLE PHASE MOTOR. HORSEPOWER AS NOTED � FIRE ALARM MANUAL PULL STATION AH VA -VOLT AMMETER RACEWAY LEGEND TIME DELAY CONTACT, NORMALLY CLOSED, TIME TO CLOSE THERMO SWITCH, NORMALLY CLOSED ADDITIONAL SYMBOLS F -EMERGENCY STOP THREE PHASE MOTOR. 5/i� �L�N L�C��N1� PROPOSED POWER RELAY CONTACT, NC FLOWSWITCH OKKIRK KEY INTERLOCK HP HORSEPOWER AS NOTED OS SOUND SYSTEM SPEAKER � RELAY CONTACT, INSTANTANEOUS CHANGE POWER TRANSFORMER O FLOWSWITCH, NORMALLY OPEN 0 V SOUND SYSTEM VOLUME CONTROL TEL - PROPOSED TELEPHONE RELAY CONTACT, NO CONTROL POWER TRANSFORMER HP SINGLE PHASE MOTOR. HORSEPOWER AS NOTED TELM PROPOSED INSTRUMENTATION TRANSFORMER ELECTRICAL PLUG DOORBELL w Fo - PROPOSED FIBER OPTICS PRESSURE SWITCH O FLOWSWITCH O cl) Q Z OP f�ACV77 FLM LEGENO PRESSURE SWITCH, NORMALLY OPEN FLOWSWITCH, NORMALLY CLOSED I► � uj VALVE SYMBOLS IPUILOING CURRENT TRANSFORMER ❑� DISCONNECT SWITCH PILOT VALVE SOLENOID 480 VOLT EXPOSED RACEWAY WFUSED DISCONNECT SWITCH 480 VOLT WIRING CONCEALED, UNDERGROUND, EMBEDDED, OR CONCRETE ENCASED RACEWAY PRESSURE SWITCH � � JVOLTAGE TRANSFORMER aF PRESSURE SWITCH, NORMALLY CLOSED 2 POLE SWITCH L` VALVE 120/208/240 VOLT EXPOSED RACEWAY Oo J \I a � CONTACTOR � COMBINATION MOTOR STARTER AND DISCONNECT SWITCH 120/208/240V WIRING CONCEALED, UNDERGROUND, EMBEDDED, OR CONCRETE ENCASED RACEWAY CT � � V CHECK VALVE LADDER LOGIC LINETYPES _ Z � CAPACITOR CONTROL OR INSTRUMENTATION EXPOSED RACEWAY in in � O RECEPTACLES AND JUNCTION BOX SYMBOLS ENGINE GENERATOR CONTROL OR INSTRUMENTATION, UNDERGROUND, EMBEDDED, OR CONCRETE ENCASED RACEWAY COMPONENT INSTALLED INSIDE ENCLOSURE � J U �J CEILING JUNCTION BOX GENERATOR CONNECTION �--� WALL JUNCTION BOX CONTROL VALVE - HOME RUN TO PANELBOARD OR AS INDICATED COMPONENT INSTALLED ON FRONT OF ENCLOSURE 3 POLE SWITCH � uj J RECEPTACLE FLOOR JUNCTION BOX CONDUIT RUN, BROKEN AND CONTINUED SAME FIELD CONNECTED W PID FORMAT S SHEET OR AS NOTED COMPONENT SUPERSCRIPT N SOLID NEUTRAL � DUPLEX WALL RECEPTACLE , 120V WP FLEXIBLE CONDUIT TB TERMINAL BLOCK =WEATHERPROOF G =GROUNDED IG =ISOLATED GROUND X=MEASURED OR INITIATING VARIABLE # Y-READOUT OR FUNCTION XYZ - Z=MODIFIER CONDUIT RUN. HATCH MARKS INDICATE NUMBER OF CONDUCTORS P&ID BUBBLE IDENTIFICATION CHART �11 GFI =GROUND FAULT INTERRUPTER ABC SURGE PROTECTION DEVICE DOUBLE DUPLEX ABC=LOOP NUMBER INSTRUM� ENT CALLOUT INDICATING CONDUIT SIZE, NUMBER y" GRC, 2-#12 AND SIZE OF WIRE. EXISTING FUNCTION BUBBLE INSTRUMENT IDENTIFICATION BUBBLE 0 o P o SURGE PROTECTION DEVICE � SINGLE RECEPTACLE, 120V CALLOUT INDICATING CONDUIT PER SCHEDULE ISA STANDARDS FOR P&ID � 1st LETTER (MEASURED I 2nd LETTER (READOUTS 3rd LETTER OR INITIATING VARIABLE) OR FUNCTION) (MODIFIER) (ALTERNATIVE) SINGLE RECEPTACLE, 208V XXX FIELD MOUNTED DEVICE OR INSTRUMENT 0 ¢ W � GROUNDING SYSTEM SYMBOLS � Y m � DUPLEX FLOOR RECEPTACLE, 120V SPECIAL PURPOSE WALL RECEPTACLE, kt) CONDUIT BENT UP OR TOWARD � CONDUIT BENT DOWN OR AWAY FRONT PANEL MOUNTED INSTRUMENT OR DEVICE (LOCAL PANEL) 00 � 1 GROUND A g ANALYSIS � ALARM � BURNER (BATTERY) � � (BACK) METAL PIPE GROUND RATING AS NOTED C D COMMUNICATION � CONTROL � CLOSED DENSITY (DELAY) 010 CLOCK E VOLTAGE I I ] CAPPED CONDUIT o 1. _ _ _ _ _ _ _ _ _ _ _ � _ _ _ _ _ _ BACK PANEL MOUNTED INSTRUMENT OR DEVICE (LOCAL CD PANEL) � CONNECTION POINT, EXOTHERMIC WELD. F FLOW � � FAIL (FLOW) ONE -LINE DIAGRAM INFORMATION CADWELD OR APPROVED EQUAL. �N TELEVISION G GAS I IGREEN BULB o O ROD SIZED PER N.E.C. USE EXOTHERMIC WELD CONNECTION AT TELEPHONE H HAND I MANUAL I HIGH CURRENT (INTRUSION) � INDICATE � EXISTING EQUIPMENT AND CONDUIT FRONT PANEL MOUNTED INSTRUMENT OR DEVICE(LAB ROOM PANELGROUND ) w __j cn J POWER (EQUIPMENT) � o THE GROUND ROD. _�_ _ _ _ _ _ _ _ I � PROPOSED EQUIPMENT AND CONDUIT0 OPERATOR INTERFACE DISPLAY (LOCAL PANEL) N J Z O uj � C� PIGTAIL, BARE COPPER, LENGTH AS TELEPHONE/DATA WITH CABLE K L TIME CONTROL STATION I I LEVEL LIGHT LOW GROUNDING EQUIPMENT AND CONDUCTORS w � � Z REQUIRED, 8' MINIMUM. a TELEPHONE DATA WITHOUT CABLE � M I I MOTION MIDDLE I I ���,�����,�����,����_ CONDUIT WIRING OR EQUIPMENT TO BE REMOVED � OPERATOR INTERFACE DISPLAY (LAB ROOM PANEL) � � W g W W o � CONNECTION POINT, MECHANICAL, N 0 USERS CHOICE USERS CHOICE � I OPEN � SWITCH OUTLETS COMPRESSION TYPE. P Q ---------------- PRESSURE I (PUMP) I (PRESSURE) QUANTITY (EVENT) � TOTALIZE � � � � O � N a' C:) ELECTRICAL SITE PLAN SYMBOLS S O STANDARD SWITCH, 120VAC, 20 AMP UTILITY POLE AND GUY WIRE R RADIATION (REQ'D) I RECORD I RED BULB GENERAL NOTES N a cc HH MANHOLE OR HANDHOLE S (T. WAY 3-WAY SWITCH, 120VAC, 20 AMP S T SPEED (SMOKE) I SWITCH I SOLENOID TEMPERATURE � TRANSMITTER � (TRANSMITTER) 1. THIS IS A STANDARD LEGEND. NOT ALL OF THE INFORMATION SHOWN ON THIS PAGE WILL APPEAR IN THIS SET OF PLANS. w ¢ � o3 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ � � HH S O 3-POSITION SWITCH, 120VAC, 20 AMP, U MULTI VARIABLE MULTI FUNCTION � � Q a � W �P BURIED POWER VAULT OR MANHOLE HOA HOA LABEL SWITCH POSITION V VALVE VISCOSITY (pH) I I 2. THESE DRAWINGS ARE DIAGRAMMATIC ONLY; EXACT LOCATIONS OF ELECTRICAL EQUIPMENTco co HAND -OFF -MOTION OR PHOTO W WEIGHT SHALL BE DETERMINED IN THE FIELD BY THE CONTRACTOR. THE INSTALLATION OF ALL EQUIPMENT ll`_ X UNCLASSIFIED SHOWN ON THESE DRAWINGS OR DESCRIBED IN THE SPECIFICATIONS SHALL CONFORM TO THE o T TELEPHONE VAULT OR PEDESTAL S SINGLE -POLE S PILOT -LIGHTED Y I USERS CHOICE RELAY (TRANSDUCER) I REQUIREMENTS SET FORTH IN THE LATEST EDITIONS OF ALL APPLICABLE CODES AND UTILITY DEE P _ _ _ _ _ _ _ _�_ _ _ _ _ _ _ _ � _ _ _ _ _ _ COMPANY STANDARDS. CONTACT THE UTILITY COMPANY REPRESENTATIVES AND VERIFY THEIR z F FIBER OPTICS VAULT OR PEDESTAL S DOUBLE -POLE ISK KEY -OPERATED Z POSITION I I REQUIREMENTS. W � 0­0 LUMINAIRE S THREE WAY S LOW VOLTAGE LV � � � � 3. NOTIFY THE ENGINEER IMMEDIATELY IF CONFLICTS IN EQUIPMENT LOCATIONS ARE DISCOVERED OR IF PROBLEMS ARISE DUE TO FIELD CONDITIONS, LACK OF INFORMATION OR ANY OTHER SCALE: SHOWN 3 S FOUR WAY S MASTER REASON. NO PAYMENT WILL BE MADE FOR CHANGES WHICH HAVE NOT BEEN REVIEWED BY THE o" 1" 2" 4 M I I ENGINEER. PAD -MOUNT TRANSFORMER S DIMMER❑ PUSHBUTTON I I DRAWING IS FULL SCALE WHEN BAR MEASURES 2" DWG NO.: SHEET NO.: S OCCUPANCY I I OS SENSOR E01 19 34