HomeMy WebLinkAboutS-393924POWER TERMINAL BLOCKS,
TYPICAL
POWER JUNCTION BO.
NEMA4XSS ENCLOSURE,
12" DEEP. SECURE TO
EXTERIOR PANEL.
GROMMETED CABLE
FITTING, TYPICAL. SEE
DETAIL THIS SHEET.
POWER CABLE WITH
CONDUCTORS INSIDE
OVERALL JACKET
(MANUFACTURER CABLE)
CADWELD TYPE TA.
CADWELD CABLF T^
CABLE TEE CONNECT
PE
If
EXPLOSION -PROOF SEAL
FITTING)
INSTRUMENTATION AND
CONTROL TERMINAL
%AL AS
ISTRUMENTATION AND
ONTROL JUNCTION BOX.
NEMA4XSS ENCLOSURE,
12" DEEP. SECURE TO
EXTERIOR PANEL.
GROMMETED CABLE
FITTING, TYPICAL. SEE
DETAIL THIS SHEET.
EXTERIOR JUNCTION
BOX OUTLINE
)M
EXPLOSION -PROOF SEAL
FITTING)
JUNCTION BOX ENCLOSURE
IN I tKIUK tLtVA I IUN Ut I AIL
NOT TO SCALE
CADWELD TYPE RR.
CADWELD ENE, n n o' r T^
UPPER REBAR CO
#6 COPPER CONDUCTOR
GROUND TEE DETAIL
NOT TO SCALE
CADWELD TYPE ^"
#6 COPPER CONDUCTOR
CADWELD CABLE TO
GROUND ROD CONNECTION.
5/8" X 8'COPPER GROUND
ROD.
GROUND TEE DETAIL
NOT TO SCALE
SECURE TO CONCRETE PAD
WITH 1/2" SST CONCRETE
ANCHORS, TYP. EMBED 3" MIN.
#5 @ 12" 0. C, EW,
CENTER IN SLAB
6" MIN CRUSHED BASE
COURSE COMPACTED TO
FIRM AND UNYIELDING
CONDITION.
#6 COPPER CONDUCTOR
GROUND REBAR DETAIL
NOT TO SCALE
CADWELD TYPE XA.
nnnln►ELD CABLE TO CABLE
CONNECTION.
#6 COPPER CONDUCTOR
(TYPICAL)
GROUND CROSS DETAIL
NOT TO SCALE
GROUNDING CONNECTION DETAILS
NOT TO SCALE
E'1
JUNCTION BOX ENCLOSURE
EXTERIOR ELEVATION DETAIL
n^�innrTr HOVER.
GROUND ROD DETAIL
NOT TO SCALE
ROUND ROD PROTECTOR 13"
IEIGHTWITH COVER. PIPE
& 12R-12T, OR EQUAL.
HOFFMAN NEMA 1 SS
ENCLOSURE, 20" DEEP.
KEY LOCK HANDLE
STUD MOUNTED SS GRATING
ON FRONT AND SIDES OF
EXTERIOR PANEL ENCLOSURE.
CABL
NECESSA
TER
TERMINATION
BOX ENCLOSURE
CABLE FROM WET WE
NATIVE OR STRUCTURAL
FILL COMPACTED TO 95%
MAX DRY DENSITY PER
MODIFIED PROCTOR
UNDISTURBED NATIVE SOIL
PROPOSED TERMINAL
BLOCK WITHIN JUNCTION
BOX ENCLOSURE
FIELD WIRE
CONNECTIONS
GRIP (CGB), SIZE
BLE DIAMETER
CABLE TRANSITION DETAIL (TYPICAL
NOT TO SCALE
NATIVE MATERIAL COMPACTED TO RED ELECTRICAL WARNING
95% PER ASTM D1557 OR AS TAPE CENTERED OVER RESTORE SURFACE TO EXISTING
REQUIRED PER PLAN � � EACH CONDUIT IN TRENCH CONDITION OR BETTER PER PLANS
(TYP)
\
U.
•a. •o. •a. •a. •a. •a. •a. •a. •a. •a. •a.
\\
0
w
on
ri•o.' •-o •o.' •o.' •o.' -o.'
—
o.''•o.''•o.''•o.''•o. '•o.''•o.''•o.''•o.''•o.' •o.''•o.''
Q
\
9
0.'
LJJ
`f)
z
—
-o.' •o.' •o.' •o.' •o.' -o.' •o.' •o.' •o. •o. -o.'
•o.' •o.' •o.' -o.' •o.' •o.' •o.' •o.' -o.' •o.' •o.' •o.
_
co
o
> z
611
COVER OVER
3��
:: y : !•;:. _\\
_
HIGHEST CONDUIT IN
ho „..
TRENCH '\ `� `� SAND BEDDING MATERIAL PER
'ER GROUND ROD. j }..'3„ -- WSDOT SPECIFICATION 9-03.13
MINIMUM DEPTH BELOW ELECTRICAL CONDUIT NUMBER AND
BOTTOM OF DEEPEST CONDUIT SIZE VARY AS PER SITE PLAN. MAINTAIN
INSTALLED IN TRENCH 12" SPACING BETWEEN TELEMETRY
CONDUITS AND OTHER CONDUITS.
TYPICAL ELECTRICAL TRENCH DETAIL
NOT TO SCALE
NOTE' BURY DEPTH OF CONDUIT AND HORIZONTAL SPACING SHALL
BE CONFIRMED WITH SERVING UTILITY BEFORE CONSTRUCTION.
co
O
Lo
0
ul
A
co
co
441
w
e.
UC-4
zco
r~ o 0
V � N
Z0 �
� �c/)
W d �
z
uo o
z� W�
WN
= N
_ O �
�i: m N
cn
J
Q
H
uj
in
Q
c.i
cc
v
uj
J
uj
U-
0
co
U
W
J
0
w
Z
0
U
OLu
J
of
—
w
U-
0
z
0
w
J
Lu
Lu
0
U
rn
O
W
0V
C
0
Lo
N
W
N
cn
w
Q
W
U
0
0
6
co
co
CV
ti
m
o
0
o
W
z
W
W
Lu
cr_
Lu
cc
ml
0
cc
Lu
0
of
z
SCALE' SHOWN
�1 2
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
DWG NO.: SHEET NO.:
E06 1 24 173�4_j