Loading...
HomeMy WebLinkAboutS-393927O co ° OA � \ .�,LO O �� cn cn to Z 0 OC �" U o N W W fly Zoo W Z W °° "' z z w d� �Z Z w z : wr'.c� U o Z0� z�u W�=N 0� mN 0 a cn uj J 0 � uj mr 0 cn J CJ 0 V J a uj J uj U- Lu W Q Lu 00 m 0 z 0 0 0 w J * NUMBER OF LAMPS PER FIXTURE o z Lu OLu Z w Cn o z z � � W uj JLu Z 0 w CV CV ZO 0 0 CV CV uj cc Q Q w w 0 Q CV Q m o o o � o W Ea Ea W � SCALE: SHOWN DRAWING IS FULL SCALE WHEN BAR MEASURES 2" DWG NO.: SHEET NO.: E09 27 V344.1 ELECTRICAL EQUIPMENT AND INSTRUMENTATION SCHEDULE ITEM DESCRIPTION MANUFACTURER MODEL NO. A SERVICE ENTRANCE DISCONNECT SWITCH - NEMA4X HDL 36100 WITH STAINLESS STEEL, HEAVY DUTY SERVICE RATED, 100-AMP, 480 SQUARE D ENCLOSURE OR EQUAL VOLT, 18,000 AMP INTERRUPTING RATING. © FLOWMETER -WITH REMOTE TRANSMITTER SEE SPECIFICATIONS SEE SPECIFICATIONS C _ GENERATOR RECEPTACLE 100A, 480 VOLT, 4-POLE, 3-WIRE, MODEL ADR1034 W/ THREADED CAP, WEATHER PROOF. APPLETON MODEL AJA100 ANGEL ADAPTER OR EQUAL LIGHTING FIXTURE SCHEDULE MANUFACTURER LAMP LAMP CATALOG TYPE DESCRIPTION NAME MANUFACTURER CATALOG NO. QTY. N0. REMARKS LED LIGHT FIXTURE, 120 VAC, 4'-4" LONG, 45 WATT, 60,000 HOUR LED, HIGH EFFICIENCY DRIVER, HIGH -IMPACT INTEGRATED Al ACRYLIC LENS, MOLDED FIBERGLASS HOUSING, CEILING LITHONIA FEM L48 6000LM IMAFL 1 LED MOUNTED, U.L. LISTED FOR WET LOCATIONS. LED OUTDOOR AREA LIGHT - (l)-27W 10C LED. 700mA, 5000K COLOR TEMPERATURE, 120VAC, MOUNT BOTTOM OF DSXW1 LED 10C 700 50K T3M 120 INTEGRATED PANEL SCHEDULE L N0. L LOCATION: MCC SERVING: LIFT STATION 240/120 60 AMP VOLTS 3 WIRE MAIN CIRCUIT DESCRIPTION KVA AMP AMP KVA CIRCUIT DESCRIPTION OUTDOOR RECEPTACLE 0.18 20 POWER CONDUIT AND CONDUCTOR SCHEDULE CIRCUIT SOURCE DESTINATION TRADE SIZE (QUANTITY) CONDUCTORS NOTES P1 UTILITY TRANSFORMER MAIN SERVICE DISCONNECT SWITCH 1 1/4" (3) - #39 (1) -#3 N P2 MAIN SERVICE DISCONNECT SWITCH UTILITY METER 1 1/4" (3) - #3j (1) -#3 N, (1) - #8 GRD P3 UTILITY METER AUTOMATIC TRANSFER SWITCH "ATS" 1 1/4" (3) - #39 (1) -#3 N, (1) - #8 GRD P4 AUTOMATIC TRANSFER SWITCH "ATS" MOTOR CONTROL CENTER "MCC" 1 1/4" (3) - #3, (1) -#3 N, (1) - #8 GRD P5 STANDBY GENERATOR MANUAL TRANSFER SWITCH "MTS" 1 1/4" (3) - #39 (1) -#3 N, (1) - #8 GRD P6 GENERATOR RECEPTACLE MANUAL TRANSFER SWITCH "MTS" 1 1/4 " (3) - #3j (1) -#3 N, (1) - #8 GRD P� MANUAL TRANSFER SWITCH "MTS" AUTOMATIC TRANSFER SWITCH "ATS" 1 1/4" (3) - #3j (1) -#3 N, (1) - #8 GRD P8 MOTOR CONTROL CENTER "MCC" JUNCTION BOX ENCLOSURE 1" (3) - #10, (1) - #10 GRD, (5) - #14 P9 MOTOR CONTROL CENTER "MCC" JUNCTION BOX ENCLOSURE 1" (3) - #10, (1) - #10 GRD, (5) - #14 INCREASE CONDUIT SIZE AS NECESSARY P10 JUNCTION BOX ENCLOSURE PUMP 1 2" MANUFACTURER'S CABLES BASED ON MANUFACTURERS RECOMMENDATIONS INCREASE CONDUIT SIZE AS NECESSARY P11 JUNCTION BOX ENCLOSURE PUMP 2 2" MANUFACTURER'S CABLES BASED ON MANUFACTURERS RECOMMENDATIONS (ED LIGHTING PANEL, "L" BUILDING HEATER 3/4" (2) - #12, (1) - #12 GRD (ED LIGHTING PANEL, "L" DEDICATED SUMP PUMP RECEPTACLE 1" (2) - #12, (1) - #12 GRD (ED LIGHTING PANEL, "L" STANDBY GENERATOR 1" (4) - #12, (1) - #12 GRD BOCK HEATER AND BATTERY CHARGER P15 MOTOR CONTROL CENTER, "MCC" INTAKE LOUVER ACTUATOR, "LA-1 3/4" (2) - #12, (1) - #12 GRD P16 MOTOR CONTROL CENTER, "MCC" EXHAUST VENTILATOR, "EF-1" 3/4" (2) - #12, (1) - #12 GRD P17 LIGHTING PANEL, "L" NORTH SITE LIGHT 1" (2) - #12, (1) - #12 GRD P18 LIGHTING PANEL, "L" SOUTH SITE LIGHT 1" (2) - #12, (1) - #12 GRD P19 LIGHTING PANEL, "L" TELEMETRY PANEL, "RTU" 3/4" (2) - #12, (1) - #12 GRD CONTROL CONDUIT AND CONDUCTOR SCHEDULE CIRCUIT SOURCE DESTINATION TRADE SIZE (QUANTITY) CONDUCTORS NOTES C1 HEATING THERMOSTAT BUILDING HEATER 3/4" (2) - #14, (1) - #14 GRD C2 TELEMETRY PANEL, "RTU" VAULT JUNCTION BOX 1" (10) - #14, (1) - #14 GRD C3 VAULT JUNCTION BOX INTRUSION AND CHECK VALVE SWITCHES 3/4" (8) - #14, (1) - #14 GRD C4 VAULT JUNCTION BOX FLOOD SWITCH 3/4" (2) - #14, (1) - #14 GRD C5 TELEMETRY PANEL, "RTU" BUILDING INTRUSION SWITCH 3/4" (2) - #14, (1) - #14 GRD C6 TELEMETRY PANEL, "RTU" JUNCTION BOX ENCLOSURE 1" (6) - #14, (1) - #14 GRD C7 JUNCTION BOX ENCLOSURE FLOAT SWITCHES 2" (3) MANUFACTURER'S CABLES �$ AUTOMATIC TRANSFER SWITCH "ATS" STANDBY GENERATOR 1" (3) - #14, (1) - #14 GRD C9 TELEMETRY PANEL, "RTU" STANDBY GENERATOR 3/4" (8) - #14, (1) - #14 GRD C10 TELEMETRY PANEL, '�RTU" AUTOMATIC TRANSFER SWITCH "ATS" 3/4" (2) - #14, (1) - #14 GRD C11 TELEMETRY PANEL, "RTU" INTRUSION DISABLE SWITCH 3/4" (2) - #14, (1) - #14 GRD C12 COOLING THERMOSTAT MOTOR CONTROL CENTER "MCC" 3/4" (4) - #14, (1) - #14 GRD C13 TELEMETRY PANEL, "RTU" MOTOR CONTROL CENTER "MCC" 1 1/4" (30) - #14, (1) - #14 GRD C14 TELEMETRY PANEL, "RTU" SMOKE DETECTOR 3/4" (4) - #14, (1) - #14 GRD INSTRUMENTATION CONDUIT AND CONDUCTOR SCHEDULE CIRCUIT SOURCE DESTINATION TRADE SIZE (QUANTITY) CONDUCTORS NOTES J1 TELEMETRY PANEL, RTU FLOW METER TRANSMITTER 1 (1) 2-CONDUCTOR SHIELDED CABLE, (6) - #149 (1) - #14 GRD J2 FLOW METER TRANSMITTER VAULT JUNCTION BOX (2) 1 1/2 " MANUFACTURER'S CABLES J3 VAULT JUNCTION BOX FLOW METER (2) 1 1 /2" MANUFACTURER'S CABLES J4 TELEMETRY PANEL, "RTU" JUNCTION BOX ENCLOSURE 1" (1) 2-CONDUCTOR SHIELDED CABLE J5 JUNCTION BOX ENCLOSURE LEVEL TRANSMITTER 1" MANUFACTURER'S CABLE J6 TELEMETRY PANEL, "RTU" ANTENNA 2" (1) COAXIAL CABLE J7 TELEMETRY PANEL "RTU" �� �� MOTOR CONTROL CENTER MCC 2 (4) 2-CONDUCTOR SHIELDED CABLES, (3) CAT 5E SHIELDED ETHERNET CABLES