HomeMy WebLinkAboutEx_03_Landscape_PlanSITE PLANNING
LANDSCAPE
ARCHITECTURE
A S P E N
CONTACT: PAUL J. DIX
ASPEN DESIGN GROUP
P.O. BOX 2394
ISSAQUAH, WA 98027
(425) 292-9845 (PHONE)
PAUL J. DIX
CERTIFICATE NO. 620
STATE OF WASHINGTON
REGISTERED LANDSCAPE ARCHITECT
Revi
e
w
O
n
l
yAAANNNNNNNSHEET NUMBERMEI LIN SHORT PLATA-NNNNNNN
COVER SHEET
PRELIMINARY SUBDIVISION SUBMITTAL
MEI LIN SHORT PLAT
MEI LIN SHORT PLATPR:C:LUA:LANDSCAPE SHEET INDEX
MEI LIN SHORT PLAT
SECTION 8, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M.
CITY OF RENTON, KING COUNTY, STATE OF WASHINGTON
PROJECT ADDRESS:
OWNER / DEVELOPER:
LANDSCAPE SITE DATA
VICINITY MAP
SHEET 1 COVER SHEET
SHEET 2 TREE PLAN
SHEET 3 LANDSCAPE PLAN
SHEET 4 IRRIGATION PLAN
SHEET 5 LANDSCAPE DETAILS
SHEET 6 IRRIGATION DETAILS
TAX PARCEL NUMBER:
SITE PARCEL AREA:
CURRENT ZONING:
COMPREHENSIVE PLAN:
Wang Mei Lin
311990-0160
41,000 s.f. / 0.94 ACRES (+/-)
RESIDENTIAL 8 (R-8)
RMD - RESIDENTIAL MEDIUM DENSITY
1833 N.E. 12th Street
RENTON, WA 98055
PROPOSED USE:RESIDENTIAL SHORT PLAT
CRITICAL AREAS:HIGH EROSION HAZARD
MODERATE TO HIGH LANDSLIDE HAZARD
SENSITIVE AND PROTECTED SLOPES
BLVDNPARK
D R
NNE ST16TH
BLVD NESUNSET
PARK D
R
NE NENEABERDEENAVE NEHOUSERN 8th STREET
SITE
RECEIVED
03/24/2020
amorganroth
PLANNING DIVISION
EXHIIBT 3
DocuSign Envelope ID: 44E7B13B-E61D-42E2-9010-CB07930C65F3
15.0' TOP OF SLOPE BUFFERN.E. 12th STREET(PUBLIC RIGHT-OF-WAY)MONTEREY AVE NE NE 12TH ST(PUBLIC RIGHT OF WAY)TREE #1TREE #2TREE #3TREE #4TREE #5TREE #6TREE #7TREE #8TREE #9TREE #10TREE #11TREE #12TREE #13TREE #14HYDRANGEATREE #15TREE #17JUNIPERSTREE #16TREE #185LAKEWASHINGTONBLVDNPARK
DRN
JONES AVE NE
ABERDEEN AVE NE
EDMONDS AVE NENEST16TH
BLVD
NE
SUNSETPA
RK
DRNE
NE
SUNSE
T8EDMONDS AVE NE
7THSTNESUNSETBLVD NE
ABERDEENAVE NEHOUSERWAYNGARDENST8THNAVEN
AVE N
AVE N
AVE NRENTONAIRPORTMUNICIPAL
AVENSITE PLANNINGLANDSCAPEARCHITECTUREA S P E NCONTACT: PAUL J. DIXASPEN DESIGN GROUPP.O. BOX 2394ISSAQUAH, WA 98027(425) 292-9845 (PHONE)PAUL J. DIXCERTIFICATE NO. 620STATE OF WASHINGTONREGISTERED LANDSCAPE ARCHITECTReview OnlyTREE RETENTION NOTESMEI_LIN_SHORT_PLAT
MEI_LIN_SHORT_PLAT
MEI_LIN_SHORT_PLATPRELIMINARY SUBDIVISION SUBMITTALPRELIMINARY TREE PLANAAANNNNNNNSHEET NUMBER
LUA:C:A-NNNNNNNPR:N O R T H N O R T H TREE PLANSCALE: 1" = 30.0'TREE DENSITY TABLEProtection Measures During Construction:a. Construction Storage Prohibited: Applicant may not fill, excavate, stack or b. Fenced Protection Area Required: Prior to development activities, the applicant d. Impervious Surfaces Prohibited within Drip Line: The applicant may not installe. Restrictions on Grading within the Drip Lines of Retained Trees: The grade levelf. Mulch Layer Required: All areas within the required fencing shall be covered g. Monitoring Required during Construction: The applicant shall retain a certifiedh. Alternative Protection: Alternative safeguards may be used if determined to addTREE RETENTION WORKSHEETProtection measures in this subsection shall apply for all trees that are to be retained on site and off site. Off-site trees containing drip lines that encroachonto the site under construction shall be considered protected trees unless it is determined the abutting property owner is in compliance with Subsection Cof this Section, Allowed Tree Removal Activities. All of following tree protectionmeasures shall apply:or store any equipment, dispose of any materials, supplies or fluids, operate any equipment, install impervious surfaces, or compact the earth in any way within the area defined by the drip line of any tree to be retained.shall erect & maintain a six-foot (6') high chain link temporary construction fencearound drip lines of all retained trees or at distance surrounding the tree equal to one & one-quarter feet (1-1/4') for every one inch (1") of trunk caliper, whichever is greater or along perimeter of tree protection tract. Placards shall be placed onfence every fifty feet (50') with words: “NO TRESPASSING–PROTECTED TREES"or on each side of fencing if less than fifty feet (50'). Site access to individuallyprotected trees or groups of trees shall be fenced and signed. Individual trees shall be fenced on four (4) sides. In addition, applicant shall provide supervision whenever equipment or trucks are moving near trees.c. Protection from Grade Changes: If grade level adjoining to a tree to be retained is to be raised, the applicant shall construct a dry rock wall or rock well around tree. The diameter of this wall or well must be equal to the tree’s drip line.impervious surface material within the area defined by the drip line of any tree tobe retained.around any tree to be retained may not be lowered within the greater of the following areas:(i) the area defined by the drip line of tree, or (ii) an area around the tree equal to one and one-half feet (1-1/2') in diameter for each one inch (1")of tree caliper. A larger tree protection zone based on tree size, species, soil, or other conditions may be required. (Ord. 5676, 12-3-2012)completely and evenly with a minimum of three inches (3") of bark mulch prior to installation of protective fencing. Exceptions may be approved if the mulch will adversely affect protected ground cover plants. (Ord. 5676, 12-3-2012)arborist or licensed landscape architect to ensure trees are protected from development activities and/or to prune branches and roots, fertilize and wateras appropriate for any trees and ground cover that are to be retained.equal or greater tree protection. (Ord. 5676, 12-3-2012; Ord. 5841, 6-12-2017)LOTLOT SIZEMIN. SIG.TREESREQ'D.NEWTREESRETAINEDTREESCOMPLIANTN/ATOTAL ONSITE SIGNIFICANT TREES: HAZARD TREES / LOW RETENTION VALUE / DYING:TREES INCL. FOR RETENTION CALC.: #(IN.)SPECIES(FT.)RETAINHEALTHDLRDBH14 (11 SIGNIFICANT, 3 LANDMARK)01467123459121011814"BIGLEAF MAPLEGRAND FIR20'19'28'YESYESYESYESCOMMENTSTOTALTREESMEI LIN SHORT PLATSECTION 8, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M.CITY OF RENTON, KING COUNTY, STATE OF WASHINGTONEXISTING ON-SITE TREE INVENTORY14"14"14"14"12"14"30"14"30"24"36"BIGLEAF MAPLEBIGLEAF MAPLEBIGLEAF MAPLEBIGLEAF MAPLEBIGLEAF MAPLEBIGLEAF MAPLEBIGLEAF MAPLEBIGLEAF MAPLEDOUGLAS FIRW. RED CEDARYESYESYESYESYESYESYESYESLANDMARKLANDMARKLANDMARKN/AN/AN/AN/AN/AN/A13N/A?ACER SP.YESNON-SIGNIFICANT TREE14N/A?ACER SP.YESNON-SIGNIFICANT TREE152"ACER PALMATUM161.25"ACER PALMATUM1718YESNON-SIGNIFICANT TREEYESNON-SIGNIFICANT TREEN/A8"DECIDUOUSYESN/A12"DECIDUOUSYESN/AN/AVERY GOODVERY GOODVERY GOODVERY GOODVERY GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODDocuSign Envelope ID: 44E7B13B-E61D-42E2-9010-CB07930C65F3
15.0' TOP OF
SLOPE BUFFER
N.E. 12th STREET
(PUBLIC RIGHT-OF-WAY)NE 12TH ST
(PUBLIC RIGHT OF WAY)
10.0' ON-SITE
LANDSCAPE
AT STREET
FRONTAGE
V
+
+
+
+
+
+
++
++
**********+*************+
***
GS, 60 sf FC, 40 sf
AU, 30 sf
GS, 55 sf
AU, 35 sf
AU, 30 sf
FC, 60 sf GS, 35 sf
ROCK BED,
35 sf
ROCK BED,
30 sf
a
b
c
d
e
f
ROCK BED,
35 sf
ROCK BED,
30 sf
ROCK BED,
55 sf
ROCK BED,
35 sf
8.0'(w) PLANTING STRIP
46.5'56.0'
LAWN,
LANDSCAPE AREA
= 983 s.f.
LANDSCAPE AREA
= 634 s.f.LANDSCAPE AREA
= 544 s.f.
= 232 s.f.
LAWN,
= 297 s.f.
LAWN,
= 42 s.f.
PLPL
10.0' ON-SITE
LANDSCAPE
AT STREET
FRONTAGE
SITE PLANNING
LANDSCAPE
ARCHITECTURE
A S P E N
CONTACT: PAUL J. DIX
ASPEN DESIGN GROUP
P.O. BOX 2394
ISSAQUAH, WA 98027
(425) 292-9845 (PHONE)
PAUL J. DIX
CERTIFICATE NO. 620
STATE OF WASHINGTON
REGISTERED LANDSCAPE ARCHITECT
Revi
e
w
O
n
l
y
MEI LIN SHORT PLATMEI LIN SHORT PLATMEI LIN SHORT PLAT
PRELIMINARY SUBDIVISION SUBMITTAL
PRELIMINARY LANDSCAPE PLANAAANNNNNNNSHEET NUMBERLUA:C:A-NNNNNNN PR:N O R T H N O R T H
LANDSCAPE PLAN
SCALE: 1" = 20.0'
LANDCAPE NOTESLANDSCAPE SCHEDULE
EVERGREEN TREES
ORNAMENTAL GRASS / FERNS / VINES
EVERGREEN SHRUBS
DECIDUOUS TREES
GROUNDCOVER PLANTS
DECIDUOUS SHRUBS
KEY ABR.BOTANICAL NAME COMMON NAME SIZE
KEY ABR.BOTANICAL NAME COMMON NAME SIZE
KEY ABR.BOTANICAL NAME COMMON NAME
KEY ABR.BOTANICAL NAME SIZE #ARIDCOMMON NAME
A. BRILLIANCE SERVICEBERRY
PACIFIC FIRE VINE MAPLE
HEDGE MAPLE
SHORE PINE
DOUGLAS FIR
VIRESCENS RED CEDAR
2.0" Cal.
8.0'(h)
2.0" Cal.
6'(h) Min.
NATIVE
YES *
YES *
NO
YES
YES
YES *
ARIDNATIVE
YES *1 Gal. @
YES1 Gal. @
YES1 Gal. @
ARIDNATIVE
NO1 Gal.
YES2 Gal.
FRAGARIA CHILOENSIS
PENNISETUM ALOPECUROIDES 'HAMELN'
POLYSITCHUM MUNITUM
GAULTHERIA SHALLON
ARCTOSTAPHYLOS u. 'VAN. JADE'
BEACH STRAWBERRY
HAMELN FOUNTAIN GRASS
WESTERN SWORD FERN
SALAL
KINNIKINNICK
SIZE #ARIDNATIVE
SIZE #ARIDNATIVEKEYABR.BOTANICAL NAME COMMON NAME
KEY ABR.BOTANICAL NAME SIZE #ARIDCOMMON NAME NATIVE
RED FLOWERING CURRANT
OREGON GRAPE
5 Gal.
5 Gal.
YES *
YES *
MOCK ORANGE 5 Gal.YES*
* Cultivar of Native Plant
* Cultivar of Native Plant
* Cultivar of Native Plant
* Cultivar of Native Plant
* Cultivar of Native Plant
Nurseryman's Association by the American Standard for Nursery Stock.
= 3 tablets
= 2 tablets
= 8 tablets
= 6 tablets
Shrub
Shrub
14.
2-5 gallon
1 gallon
15.
16.
2.0" cal. - 4.0" cal.
1.5" cal. - 2.0" cal.
Deciduous tree
Deciduous tree
Apply fertilizer tablets as indicated in the following table:
A lack of maintenance shall constitute a violation of local Municipal Code.
by Owner or Lessee of the property as to pruning, watering or other
Landscaped areas on private property shall be reasonably maintained
requirements to create an attractive, safe appearance for development.
6.All plants shall meet the minimum size specified on the plan. One plant
from each grouping shall be labeled, indicating the plant name and size.
Tags shall then be removed after review.
9.
8.
7.
10.
11.
12.
areas adjacent to conc. pads/walks to compact, then add additional bark
Planting beds shall have a mix of 2"(d) layer of medium-ground bark,
or gravel rock mulch where indicated. Rake beds smooth. Tamp-down
An insecticide and fungicide application shall be performed w/ type to be
selected by contractor and submitted in writing for review & approval.
A pre & post-emergent herbicide shall be applied except at Stormwater
Tract & Street Trees. Herbicide shall be Surflan AS tank-mixed w/Roundup
(4 qt's. / acre. Adhere to all product manufacturer's directions in addition
to all environmental regulations. Do not apply in areas that drain directly
to critical sensitive areas. Do not apply when wind speed exceeds 5 mph.
Stockpile plant material upon delivery to the site in a shady location,
embedded in sawdust or mulch. Stockpile all plants near a source of
water - water at least once a day to maintain healthy plant stock.
All plants shall be installed per the planting details. Alternate staking
methods may be proposed for review and approval.
All plants shall be sprayed w/a anti-dessicant w/in the first 24 hours.
13.Install all plant material during favorable weather and within seasonal
planting limitations. Do not install plants when daily high temperatures
exceed 90°(F) degrees or low temperatures are below 32°(F) degrees.
Flowering fruit trees may need to be dug after 3 consecutive nights of
temperatures less than 45 (f) degrees in the Fall or as determined by
to 1/4"-1/2" below finish grade of conc. surface. (where occuring)
2.
3.
5.
4.
Plants shall originate from established nurseries located w/in region of
project . Plants that are not available in size specified or quantity may
be secured from outside the region if submitted for review and approval.
will be accepted unless submitted in writing for approval.
All plants shall be balled & burlapped or container grown as specified.
No container grown stock will be accepted if deemed to be root-bound.
All plastic root wrapping material shall be removed. No bare root stock
Landscape contractor shall field locate all utility lines prior to the start of
construction. The use of on-site utility plans as a part of this contract are
available for review.
a 1-year warranty from date of Substantial Completion. Contractor shall
from City w/living plants of equal size to original plant. Plants are under
Defective/dead plants shall be replaced w/in 6 months after notification
1.Plant material shall conform to guidelines established by the American
= 7 tablets6.0' - 8.0' + high Evergreen tree
17.
sidewalk or asphalt, a root barrier panel shall be added on the side of
At on-site tree locations that are 4.0' or less to utility structure, pipe, curb
shall be Deep Root UB-24-2 24"(w) x 24"(d) ribbed panels w/intermittent
the root ball that is closest to item that is to be protected. Barriers shall
panel breaks as needed to allow groundwater to flow freely and not
oversaturate rootball. Place root barrier panels in trench with vertical
ribs facing toward rootball and align in a straight fashion. Keep top of
root barrier's double-top edge at least 1/2" above finish grade.
proper maintenance. Provide a written maintenance manual for complete
maintain landscape under this contract for entire 1-year period to assure
landscape & assist in transition of maintenance from Contractor to Owner.
calendar year to the Owner to assure proper long-term maintenance of
local nursery. Weather data will be from the nearest airport location to
project site (Sea-Tac Airport, WA)
18.
after installation for 2 weeks. Thereafter, Landscape Contractor shall
Landscape Contractor shall provide watering of plants every other day
water once a week for one year between April 15th-September 15th to
coincide with the 1-year warranty period. New plants need to get fully
established. There is no nearby water source - allow for a water truck.
19.
capturing rainwater toward root zone. Add Soil-Moist polymers at plant
Construct water saucers at each large shrub & tree location to assist in
pits at a rate recommended by manufacturer. At steep slope locations,
stake trees & provide water catchment (low berm) at low side of slope.
6'(h) Min.
6'(h) Min.
#
#
EVERGREEN HUCKLEBERRY 5 Gal.YES
Landscape Contractor shall submit a "Maintenance Manual" that will
identify weekly, monthly, annual & biennial maintenance regimes.
SEED / TOPSOIL SCHEDULE
BARK MULCH
FINE TO MEDIUM BARK, HEMLOCK / FIR, PLACED TO A MINIMUM OF 3".
FORMAL LAWN (FULL SUN)
80% PERENNIAL RYE SEED
20% FINE FESCUE SEED
SEED RATE: 3 lbs./1,000 s.f. PREFERRED SEEDING TIME IS SPRING & FALL.
ASSURE PROPER WATERING DURING ESTABLISHMENT. PROVIDE TEMPORARY
FENCING FOR MIN. 3 MONTHS TO KEEP PEDESTRIANS OFF LAWN.
FORMAL LAWN SEED MIX PER "COUNTRY GREEN, INC." (www.COUNTRYGREEN.com).
RS
FC
PA
Pm
GS
MA
AU
AG
AC
AC
PC
PM
TP
AMELANCHIER G. 'AUTUMN BRILLIANCE'
ACER CIRCINATUM 'PACIFIC FIRE'
ACER CAMPESTRE **
PINUS CONTORTA
PSEUDOTSUGA MENZIESII
THUJA PLICATA 'VIRESCENS'
RIBES SANGUINEUM 'KING EDWARD VII'
MAHONIA AQUIFOLIUM
PL PHILADELPHUS LEWISII 'BLIZZARD'
+
V
VO VACCINIUM OVATUM
*
NO1 Gal.FESTUCA OVINA 'ELIJAH BLUE'ELIJAH BLUE FESCUEFO
TOPSOIL
4"(d) 3-WAY TOPSOIL PER "PACIFIC TOPSOILS, INC.: OR EQUAL WITH 2" OF
WELL-ROTTED COMPOST TILLED INTO TOP 6" OF NATIVE UNDERLYING SOIL.
MEI LING SHORT PLAT
SECTION 8, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M.
CITY OF RENTON, KING COUNTY, STATE OF WASHINGTON
HELLO DOLLY RHODO.15"-21"(w)YES *RH RHODODENDRON 'HELLO DOLLY'+
18" o.c.
24" o.c.
24" o.c.
** Utilitree for under power lines
1
1
4
4
0
5
8
11
7
15
12
95 sf
100sf
150sf
19
26
8
DocuSign Envelope ID: 44E7B13B-E61D-42E2-9010-CB07930C65F3
15.0' TOP OF
SLOPE BUFFER
N.E. 12th STREET
(PUBLIC RIGHT-OF-WAY)NE 12TH ST
(PUBLIC RIGHT OF WAY)
SITE PLANNING
LANDSCAPE
ARCHITECTURE
A S P E N
CONTACT: PAUL J. DIX
ASPEN DESIGN GROUP
P.O. BOX 2394
ISSAQUAH, WA 98027
(425) 292-9845 (PHONE)
PAUL J. DIX
CERTIFICATE NO. 620
STATE OF WASHINGTON
REGISTERED LANDSCAPE ARCHITECT
Revi
e
w
O
n
l
y
Know what's below.
before you dig.Call
R
48 hours
MEI LIN SHORT PLATMEI LIN SHORT PLATMEI LIN SHORT PLAT
PRELIMINARY SUBDIVISION SUBMITTAL
PRELIMINARY IRRIGATION PLANAAANNNNNNNSHEET NUMBERLUA:C:A-NNNNNNN PR:N O R T H N O R T H
IRRIGATION PLAN
SCALE: 1" = 20.0'
IRRIGATION NOTESIRRIGATION COMPONENTS
-PIPE SIZING CHART
An electrical permit must be obtained from the City of Renton..3.
construction as seasonal pressure variations may be encountered.
The ex. static water pressure shall be verified w/the City of Renton prior to
Install PVC sleeving as shown at all pavement, sidewalk & wall locations.
Place in straight-line segments prior to pavement installation. Extend all
Adhere to all applicable codes and install irrigation components per the
manufacturer's recommendations. Verify all codes, water scheduling and
through each valve. Provide (1) spare wire at the end of the mainline run.
to the controller. Run (1) "hot" wire to each valve and (1) common wire
or strand. Splice in valve boxes only. Route all wiring in 4" elect. conduit
Install 24-volt wiring (UF 600 volt) direct burial, 14 GA., solid copper wire
The control wire shall be red, ground wire white & the spare blue.
Irrigation controller shall be set for this site to avoid irrigation between the
hours of 9:00 AM to 10:00 PM. In addition, irrigation system should not
be operated during times of moderate-high wind, excessive or adequate
seated ball valve w/ brass body & T-fitting for winterization. Plan indicates
winterized prior to the first freeze by using compressed air. Install a teflon
Provide a minimum of 10 quick coupler valves. The entire system shall be
sleeving 12" beyond edge of pavement crossing.
tests with the City of Renton.
soil moisture or during active precipitation.
9.
4.
5.
6.
7.
8.
This plan is schematic & diagrammatic. The intent of plan is to indicate
basic components, locations and scope of proposed irrigation system.
areas, adjustments may be required. Plan components are schematic.
The contractor shall assure full and even water coverage to all planting
1.
2.
project civil engineer and the City of Renton Public Works Dept.
future repairs or adjustments shall have the same system components.
damage which shall include excessive leakage or wear on system. Any
The contractor shall inspect, prevent, detect & repair any irrigation system
on a 24" x 36" mylar plan sheet to the landscape architect for review and
The irrigation contractor shall provide an irrigation as-built plan submitted
The irrigation contractor shall provide a written summary of the system
design, including any hydraulic calculations, operating instructions and
submit to the landscape architect and owner. The irrigation installer shall
arrange a site visit with the owner to review operational procedures.
The existing operating water pressure at the site shall be verified with the 13.
approval and to the owner and city for record storage.
10.
11.
12.
Landscape Contractor may make minor field adjustments as needed as
a "design-build" effort to successfully complete a fully operational system.
proposed quick coupler locations.
submittal of shop drawings and technical data.
A Hunter, Inc. product-based irrigation system may also be used upon 14.
product manufacturer.
Provide an irrigation master valve near P.O.C. Contractor to submit15.
360°
ROTARY NOZZLES
180°120°90°45°
MANUFACTURER/
DESCRIPTION
SYMBOL MODEL RAD.BODY GPM
360°180°120°90°45°
PSI PRECIP.
RATE
.861.391.823.64 40 .39 IN/HRHUNTER - POP-UP
ROTARY SPRAY
PROS-12-PRS40-CVMP 3000 26'-30'
HUNTER - POP-UP
ROTOR 3 29'PGP-ADJ-3
ON HSJ-0-2-2-2-08 SWING JOINT 4.0 50 .24 IN/HR
41'HUNTER - POP-UP
ROTOR 8 3.0 50 .45 IN/HR
34'HUNTER - RISER
ROTOR 2.0 PGP-00-2.0 2.0 45 .33 IN/HR
ROTORS
MANUFACTURER/
DESCRIPTION
SYMBOL NOZZLE RAD.BODY GPM PSI PRECIP.
RATE*
PROS-12-PRS30-CV 30 1.68 IN/HR
360°
SPRAY NOZZLES
180°120°90°45°
MANUFACTURER/
DESCRIPTION
SYMBOL MODEL RAD.BODY GPM
360°180°120°90°45°
PSI PRECIP.
RATE
HUNTER -
POP-UP SPRAY
6A
ADJUSTABLE 6'PROS-12-SI 30 3.85 IN/HR.37.44.601.26PROS-06-SI (TURF)
PROS-06-PRS30-CV (TURF)
30 .80 IN/HR
LEFT CENTER RIGHT LEFT CENTER RIGHT
1.30.65 .65
5'x15'LCS-515
SS-530
RCS-515
.18
.63.841.262.52 .32HUNTER -
POP-UP SPRAY
12A
ADJUSTABLE 12'
HUNTER - POP-UP
STRIP SPRAY 5'x30'
5'x15'LCS-515 SS-530 RCS-515
PROS-12-PRS30-CV
PROS-06-PRS30-CV (TURF)
3
8
PGP-ADJ-8
ON HSJ-0-2-2-2-08 SWING JOINT
2.0
* ALL PRECIPITATION RATES
CALCULATED AT 180° OPERATION
LINE SIZE BALL VALVE
MANUFACTURER/
DESCRIPTIONSYMBOL MODEL HOUSING COMMENTS
1" WATER METER XX PSI
STATIC PRESSURE
HUNTER - REMOTE CONTROL VALVE W/
ADJUSTABLE PRESSURE REGULATOR
ICV-XX-FS-AS-ADJ SIZE PER PLAN
HUNTER
1" FLOW SENSOR
HFS W/ FCT-100 WIRE DIRECTLY TO
CONTROLLER
A
HUNTER
DRIP CONTROL ZONE KIT
ICZ-101-LF-25 (.5-15 GPM)
HUNTER - TWO WIRE IRRIGATION
CONTROLLER
ACC-99D-PP W/ WSS-SEN,
SOIL CLIK, AND ICD-HP
2-WIRE JACKET TO BE BLUE
(ID1BLU)
1 HUNTER
1 STATION DECODER
ICD-100 NOT APPLICABLESEE DETAIL FOR STAKING
MV1 HUNTER
1" MASTER VALVE
IBV-101G-FS SUBTERRANEAN VALVE BOX WIRE DIRECTLY TO
CONTROLLER
FS1
SIZE PER PLAN
ICZ-101-25 (16-20 GPM)
PLASTIC PEDESTAL
BF 1" BACK FLOW PREVENTOR
SUBTERRANEAN VALVE BOX
SUBTERRANEAN VALVE BOX
SUBTERRANEAN VALVE BOX
SUBTERRANEAN VALVE BOX
M
DRIP
MANUFACTURER/
DESCRIPTIONSYMBOL MODEL RAD.HOUSING GPM PSI PRECIP.
RATE
HUNTER - DRIP
INDICATOR
ECO-
INDICATOR N/A N/ASEE DETAIL N/A N/A
AREA OF HUNTER
IN-LINE DRIP
ECO-MAT N/A 0.6 GPH 25SEE DETAIL FOR
BURIAL DEPTH .96 IN/HR
PIPE
MANUFACTURER/
DESCRIPTIONSYMBOL MODEL HOUSING COMMENTS
PIPE AND WIRE SLEEVING
IRRIGATION LATERAL LINE
SIZE VARIES - SEE PLAN
SCH 40 PVC
SCH 40 PVC
SCH 40 PVC
DIAMETER TO BE TWICE
THE SIZE OF THE PIPE
BEING SLEEVED
IRRIGATION MAIN LINE
1-1/2"
PIPE SIZING LEGEND
A 3/4" SCH 40 PVC
1" SCH 40 PVCB
1-1/4" SCH 40 PVCC
(0-8 GPM)
(8-12 GPM)
(12-22 GPM)
1-1/2" SCH 40 PVCD (22-30 GPM)
2" SCH 40 PVCE (30-50 GPM)
MISC. ITEMSMEI LIN SHORT PLAT
SECTION 8, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M.
CITY OF RENTON, KING COUNTY, STATE OF WASHINGTON
DocuSign Envelope ID: 44E7B13B-E61D-42E2-9010-CB07930C65F3
2-TIMES
ROOTBALL
CONSTRUCT A WATERING BASIN
OUT OF IMPORTED TOPSOIL AT
PERIMETER OF SHRUB.
SCARIFY SIDES & BOTTOM OF
PLANTING PIT
CONSTRUCT A 4"-6" LEVELING
MOUND OF COMPACTED SOIL
BOTTOM OF PLANTING PIT.
TO STREET STORM SYSTEM
OR APPROVED OUTFALL
TO DOWNSPOUT STORM
SYSTEM OR APPROVED
CONC. CURB OR CURB &
GUTTER PER PLAN.
ROAD / STREET
PLANTER STRIP
4'-0" dia. PLANTING PIT
(3'-0" dia. AT BOTTOM OF PIT)
TIGHTLINE
EQUAL (NOT A WETLAND)
12'-0" SECTION OF 4" dia. SMOOTH-WALL PVC
PERF. PIPE AT EACH TREE BEDDED IN MIN. 4"(d)
PEA GRAVEL RNVRLOPE (NO FILTER FABRIC).
INSTALL IN ROOT-WAY PARALLEL TO ROADWAY
WITH TIGHTLINE BETWEEN.
CONCRETE SIDEWALK
6"6"
3'-0" MIN. TO PIPE INVERT
2'-6" MIN. TO TOP OF GRAVEL
2" dia. x 6'-0" TREATED LODGEPOLE PINE TREE
STAKES. STAKE TREES OUTSIDE ROOTBALL
AND PARALLEL TO ROADWAY.
1" HEAVY CHAIN-LOCK TREE TIES OR SIMILAR.
REMOVE AFTER (1) 1 YEAR.
SET TREE STRAIGHT AND SET ROOTBALL ON
TAMPED SOIL PEDESTAL. TOP OF ROOTBALL
MUST REMAIN SLIGHTLY ABOVE FINISH GRADE.
BACKFILL PLANTING PIT HALF-FULL W/
IMPORTED SOIL, NO AMENDMENTS. TAMP
SOIL TO STABILIZE ROOTBALL. COMPLETE
BACKFILL OF PIT AND TAMP AGAIN.
NOTES:
PLANTING WITHIN PLANTING STRIPS OR ROOT-WAYS
SHALL NOT PROCEED UNTIL SITE PREPARATION HAS
BEEN APPROVED BY THE CITY IN ACCORDANCE W/
THE DEVELOPMENT STANDARDS.
1.
STREET TREES SHALL BE 2.0" CALIPER OR LARGER.2.
TREES SHALL CONFORM TO MOST RECENT ANSI 260.1
AMERICAN STANDARD FOR NURSERY STOCK. FIRST
TREE LIMBS SHALL BE 5'-0" ABOVE GRADE OR HIGHER.
NO TREES SHALL BE PLANTED UNTIL THE CITY HAS
3.
APPROVED THE NURSERY STOCK WITHIN DESIGNATED
INSPECTION PERIOD.
EXCAVATE HOLE INTO IMPORTED TOPSOIL TO 1" LESS
THAN HEIGHT OF ROOTBALL AND 2-x ROOTBALL WIDTH.
TAMP BOTTOM OF PIT UNDER ROOTBALL THOROUGHLY
TO KEEP TREE FROM SETTLING. BUTTRESS AT BOTTOM
4.
OF PIT NO LESS THAN 3'-0"(w) IF NEED TO REINFORCE
LATERAL SUPPORT.
DO NOT DAMAGE BALLED & BURLAPPED ROOT BALLS
WHEN PLANTING. REMOVE ALL WIRE, STRING & BURLAP
FROM TOP & SIDES OF BALL ONLY AFTER PLACING IN HOLE.
COMPLETELY REMOVE ALL FABRIC FROM GROW-BAG TREES
5.
CUT & SPREAD KINKED ROOTS TO ELIMINATE CIRCULATING
OF ROOTS AROUND CONTAINER STOCK.
CONSTRUCT SOIL WATER DAM
AROUND PLANTING PIT TO HOLD
WATER FOR DEEPER SOAKING AT
LEAST 24" FROM TRUNK.
PROVIDE 3"(d) LAYER OF COMPOSTED MEDIUM
TO COARSE BARK MULCH, MIN. 24" RADIUS AREA
AROUND TREE, PULL BARK 3" AWAY FROM TRUNK.
PLACE OSMOCOTE PLUS 15-9-12 SLOW-RELEASE
FERTILIZER OR SIMILAR AT MANUFACTURER'S
RECOMMENDED RATE OF APPLICATION EVENLY
OVER THE SOIL OF THE PLANTING PIT.
6.
NOTES (CONT.):
WATER IMMEDIATELY & THOUROUGHLY TWICE
PER WEEK DURING THE 1st MONTH, THEN ONCE
PER WEEK THROUGH REMAINDER OF THE DRY
SEASON. WATER A MIN. OF ONCE PER MONTH
7.
DURING THE SECOND SUMMER SEASON.
TO STREET STORM SYSTEM OR
APPROVED OUTFALL. OTHER
TO DOWNSPOUT STORM
SYSTEM OR APPROVED
PLANTER STRIP
4'-0" dia. PLANTING PIT
(3'-0" dia. AT BOTTOM OF PIT)
TIGHTLINE
EQUAL (NOT A WETLAND)
12'-0" SECTION OF 4" dia. SMOOTH-WALL PVC
PERF. PIPE AT EACH TREE BEDDED IN MIN. 4"(d)
PEA GRAVEL RNVRLOPE (NO FILTER FABRIC).
INSTALL IN ROOT-WAY PARALLEL TO ROADWAY
WITH TIGHTLINE BETWEEN.
3'-0" MIN. TO PIPE INVERT
2'-6" MIN. TO TOP OF GRAVEL
1.5" x 1.5" x 8'-0" T-RAIL IRON STAKES INSTALLED
OUTSIDE ROOTBALL WITH ONE STAKE LOCATED
ON SIDE OF PREVAILING WIND. WOOD STAKES
1" HEAVY CHAIN-LOCK TREE TIES OR SIMILAR.
CITY ARBORIST TO REVIEW AFTER (1) YEAR TO
SET TREE STRAIGHT AND SET ROOTBALL ON
TAMPED SOIL PEDESTAL. TOP OF ROOTBALL
MUST REMAIN SLIGHTLY ABOVE FINISH GRADE,
BACKFILL PLANTING PIT HALF-FULL W/
IMPORTED PLANTING TOPSOIL. TAMP
SOIL TO STABILIZE ROOTBALL. FINISH
BACKFILL OF PIT AND TAMP AGAIN.
NOTES:
PLANTING WITHIN PLANTING STRIPS OR ROOT-WAYS
SHALL NOT PROCEED UNTIL SITE PREPARATION HAS
BEEN APPROVED BY THE CITY IN ACCORDANCE W/
THE DEVELOPMENT STANDARDS.
1.
TREES SHALL CONFORM TO MOST RECENT ANSI 260.1
AMERICAN STANDARD FOR NURSERY STOCK. FIRST
TREE LIMBS SHALL BE 5'-0" ABOVE GRADE OR HIGHER.
NO TREES SHALL BE PLANTED UNTIL THE CITY HAS
3.
APPROVED THE NURSERY STOCK WITHIN DESIGNATED
INSPECTION PERIOD.
EXCAVATE HOLE INTO IMPORTED TOPSOIL TO 1" LESS
THAN HEIGHT OF ROOTBALL AND 2-x ROOTBALL WIDTH.
TAMP BOTTOM OF PIT UNDER ROOTBALL THOROUGHLY
TO KEEP TREE FROM SETTLING. BUTTRESS AT BOTTOM
4.
OF PIT NO LESS THAN 3'-0"(w) IF NEED TO REINFORCE
LATERAL SUPPORT.
DO NOT DAMAGE BALLED & BURLAPPED ROOT BALLS
REMOVE ALL WIRE, STRING & BURLAP FROM TOP &
SIDES OF BALL ONLY AFTER PLACING IN HOLE.
COMPLETELY REMOVE ALL FABRIC FROM GROW-BAG
5.
TREES. CUT & SPREAD KINKED ROOTS TO ELIMINATE
CIRCULING OF ROOTS AROUND CONTAINER STOCK.
CONSTRUCT SOIL WATER DAM
AROUND PLANTING PIT TO HOLD
WATER FOR DEEPER SOAKING AT
LEAST 24" FROM TRUNK.
PROVIDE 3"(d) LAYER OF COMPOSTED MEDIUM
TO COARSE BARK MULCH, MIN. 24" RADIUS AREA
AROUND TREE, PULL BARK 3" AWAY FROM TRUNK.
PLACE OSMOCOTE PLUS 15-9-12 SLOW-RELEASE
FERTILIZER OR SIMILAR AT MANUFACTURER'S
RECOMMENDED RATE OF APPLICATION EVENLY
OVER THE SOIL OF THE PLANTING PIT.
6.
WATER IMMEDIATELY & THOUROUGHLY TWICE
PER WEEK DURING THE 1st MONTH, THEN ONCE
PER WEEK THROUGH REMAINDER OF THE DRY
SEASON. WATER A MIN. OF ONCE PER MONTH
7.
DURING THE SECOND SUMMER SEASON.
ASSURE TREE IS SUFFICIENTLY SECURE IN
GROUND (AT WINDY SITES) TO ASSURE LONG
TERM SURVIVAL, TREE MAY NEED TO HAVE
STAKES IN PLACE AN ADDITIONAL YEAR.
MAY BE USED IN SHELTERED LOCATIONS WHERE
BUILDING BLOCKS STRONG WINDS.
THAN STREET TREE LOCATIONS,
ONLY INSTALL DRAINS AT SITE
LOCATIONS WHERE ADVERSE
DRAINAGE OCCURS / HARDPAN /
CLAY SOILS.
SIMILAR TO HEIGHT OF TREE NURSERY.
NOTE:
AT WINDY SITES, ASSURE ALL STAKING AND
TREE GUYING METHODS ARE USED SO TREE
WILL BE SECURE UP TO 70 mph WIND SPEED.
PRUNE DEAD / BROKEN
BRANCHES. PRUNE TO
SHAPE IF REQUIRED OR
IN A HEDGE CONDITION.
SECURE SHRUB IN AN
UPRIGHT POSITION. ADD
A SMALL WOOD STAKE
TO SECURE PLANT AT
WINDY SITES. LOOP "TIE"
AROUND STEM TO SECURE,
SHRUB, YET ALLOW FOR
PLANT MOVEMENT.
EXCAVATE SHRUB PLANTING
PIT 2-x THE SIZE OF ROOTBALL.
GENTLY BACKFILL w/IMPORTED
PLANTING TOPSOIL, COMPACT
LIGHTLY.
REMOVE THE TOP 1/3 - 1/2
OF WRAPPED BURLAP.
SET BASE OF SHRUB STEM AT
ORIGINAL NURSERY GRADE.
DO NOT COVER STEM w/BARK
OR TOPSOIL.
NOTE:
WATER NEWLY INSTALLED
SHRUBS IMMEDIATELY AFTER
PLANTING & AS NEEDED IN
DRY OR WINDY WEATHER.
MIN. 2"(d) BARK MULCH LAYER.
SPACE GROUNDCOVER
PLANTS PER LANDSCAPE
SCHEDULE.
2"(d) LAYER OF MEDIUM
SIZED BARK MULCH. ADD
MULCH PRIOR TO PLANT
INSTALLATION.
PLANTING TOPSOIL PER
PLANS & SPECIFICATIONS.
NOTES:
PROVIDE GRANULAR HERBICIDE
ABOVE & BELOW MULCH LAYER.
PRE-EMERGENT SHALL BE PER
RONSTAR, INC. OR APPROVED
EQUAL. APPLICATION SHALL BE
PER THE MANUFACTURER'S
DIRECTIONS & SHALL ADHERE
TO ALL ENVIRONMENTAL CODES
AND REGULATIONS.
SPACING, UNO.
TRIANGULAR
SCARIFY TOP 6" OF SUBGRADE
TO ELIMINATE ANY COMPACTED,
SMOOTH SURFACES TO ALLOW
IMPROVED WATER INFILTRATION
1.
KEEP PLANTS MOIST & SHADED
UNTIL TIME OF PLANTING.
2.
INSTALL GROUNDCOVER PLANTS
IN STRAIGHT, UPRIGHT POSITION
3.
LEVEL TO FINISH GRADE.
AT LOCATIONS WHERE CLAY SOIL
IS PRESENT, BLEND IN IMPORTED
SOIL, AMENDMENTS & ORGANIC
COMPOST PER AGRICULTURAL
SOIL LABORATORY RESULTS AND
4.
RECOMMENDATIONS.
AT LOCATIONS WHERE SANDY
SOIL IS PRESENT, FOLLOW NO. 4
ABOVE WITH THE ADDITION OF
5.
AGED MANURE.
CL CL
SIDEWALKCONC. CURB ORCURB & GUTTERCONC. DRIVEWAYR.O.W. LINE12.0' PERF. PIPE, TYP.12.0' PERF. PIPE, TYP.ROOTWAY
10.0' TREE PIT, TYP.10.0' TREE PIT, TYP.STREET TREESTREET TREEPLANTING PIT4.0' PIT(TYP.)CONTINUES TOUP-SLOPE TREESPVC SMOOTH-WALLTIGHTLINE BETWEENTREES, BEDDED INNATIVE MATERIAL12.0' SECTION OF 4"dia. PVC SMOOTH WALLPERF. PIPE BEDDED IN 3/8" dia. PEA GRAVELENVELOPE.CONNECT PIPE TO STORMDRAIN LINE OR DOWNSPOUTSYSTEM, OR APPROVED EQUAL.THE "PLANTING STRIP" IS THE ENTIRE AREA
BETWEEN SIDEWALK & CURB WHERE NEW
STREET TREES WILL BE PLANTED. THE
"TREE PIT" IS THE EXCVATED AREA FOR
THE TREE PLANTING. THE "ROOT-WAY" IS
NOTES:
THE LOOSENED PORTION OF PLANTING
STRIP.
1.
INSTALL CONTINUOUS 4" dia. SUBDRAIN
LINE IN PLANTER STRIP UNDER ROOT-WAY
AND TREE PIT, A MINIMUM OF 3'-0" FROM
INVERT OF PIPE TO FINISH GRADE (ADJUST
HORIZONTAL & VERTICAL LOCATION AS
REQUIRED FOR POSITIVE DRAINAGE). USE
SMOOTH WALL, PVC TIGHTLINE IN ROOT-WAY
& 12'-0' SMOOTH WALL, PVC PERFORATED
2.
PIPE IN TREE PIT. BACKFILL WITH NATIVE
MATERIAL AROUND TIGHTLINE & 3/8" dia.
PEA GRAVEL ENVELOPE AROUND PERF.
PIPE. INSTALL (1) CLEANOUT FLUSH WITH
FINISH GRADE AT APPROX. 300'-0" o.c. OR
OAT HIGH END OF EACH SYSTEM. CONNECT
TO APPROVED STORM DRAIN OR OUTFALL.
AT EACH TREE PIT, EXCAVATE & REMOVE
ALL NATIVE SOIL TO CREATE 4'-0"x10'-0"x2'-0"
DEEP PLANTING PIT. BACKFILL w/IMPORTED
PLANTING TOPSOIL OVER LOOSENED, NATIVE
SUBGRADE TO AVOID INTERFACE. SLIGHTLY
MOUND TOPSOIL BELOW ROOT BALL FOR
POSITIVE DRAINAGE. EXISTING SOIL MAY BE
USED / AMENDED AS BACKFILL ONLY IF
3.
FREE-DRAINING AND ALLOWING AT LEAST (1)
GALLON OF WATER TO DRAIN FROM PIT IN
4.0 HOURS.
BETWEEN TREE PITS CREATE A CONTINUOUS
ROOT-WAY IN THE CENTER OF THE 3'-0"(w)
PLANTER STRIP BY SCARIFICATION OF EX.
SOIL. AVOID DAMAGE TO SUB-SURFACE
DRAINAGE DURING SCARIFICATION. SET
SUBGRADE APPROX. 6"-10" BELOW FINISH
GRADE. PLACE 4"-5" IMPORTED TOPSOIL.
4.
PLACE BACKHOE BUCKET INTO SOIL 2'-0"
DEEP. LIFT & CURL BUCKET HALF-WAY OUT
OF ROOT-WAY AND ROP MATERIAL BACK
IN PLACE TO MIX NATIVE MATERIAL AND
IMPORTED TOPSOIL. ADD ADDITIONAL 2"-3"
OF IMPORTED TOPSOIL TO FINISH GRADE
AND RAKE SMOOTH.
SCALE: NOT TO SCALE
SHRUB INSTALLATION SECTION5
SCALE: NOT TO SCALE
GROUNDCOVER INSTALLATION SECTION4
SCALE: NOT TO SCALE
LAWN INSTALLATION SECTION3
NOTE:
STORM LINES ONLY FOR STREET TREE LOCATIONS.
COORDINATE STORM DRAIN LINES WITH CIVIL PLANS
TO ASSURE COMPLETE INSTALLATION.
NOTE:
STORM LINES ONLY FOR STREET
TREE LOCATIONS. COORDINATE
STORM DRAIN LINES w/ CIVIL PLANS
TO ASSURE FULL INSTALLATION.
SCARIFY TOP 6" - 8" OF SUBGRADE TO ELIMINATE
SMOOTH, COMPACTED SURFACE AND ALLOW
WATER INFILTRATION. NOTIFY ARCHITECT IF
IMPORTED TOPSOIL & AMENDMENTS, DEPTH PER
PLAN. PLACE IN 2 LIFTS AND TILL WHEN DEPTH IS
ADVERSE DRAINAGE CONDITIONS EXIST.
EARTHWORK PER CIVIL PLAN & SPECIFICATIONS.
ASSURE SUBGRADE DOES NOT BECOME
OVERCOMPACTED DURING CONSTRUCTION.
RAKE SURFACE / REMOVE DEBRIS. ESTABLISH
FINISH GRADE BY SMOOTHING / LEVELING. ROLL
GREATER THAN 4" TO MINIMIZE SOIL LAYERING.
TO FIRM UP SOIL, DRAG W/ RAKE TO SLIGHTLY
ROUGHEN SURFACE. REMOVE 1/2"+ RECESSES.
SCALE: NOT TO SCALE
CONIFEROUS TREE INSTALLATION2
SCALE: NOT TO SCALE
DECIDUOUS TREE INSTALLATION1
L5.0L4.0
SCALE: NOT TO SCALE
STREET TREE INSTALLATION6
SITE PLANNING
LANDSCAPE
ARCHITECTURE
A S P E N
CONTACT: PAUL J. DIX
ASPEN DESIGN GROUP
P.O. BOX 2394
ISSAQUAH, WA 98027
(425) 292-9845 (PHONE)
PAUL J. DIX
CERTIFICATE NO. 620
STATE OF WASHINGTON
REGISTERED LANDSCAPE ARCHITECT
Revi
e
w
O
n
l
yAAANNNNNNNSHEET NUMBERMEI LIN SHORT PLATA-NNNNNNN
LANDSCAPE DETAILS
PRELIMINARY SUBDIVISION SUBMITTAL
MEI LIN SHORT PLAT
MEI LIN SHORT PLATPR:C:LUA:L5.0L4.0
L5.0L4.0
L5.0L4.0
L5.0L4.0
L5.0L4.0
DocuSign Envelope ID: 44E7B13B-E61D-42E2-9010-CB07930C65F3
18-24" COILED WIRE
WATERPROOF CONNECTORS (2)
JUMBO VALVE BOX
DRIP ZONE KIT
MODEL ICZ-101-XX WITH
FILTER (TIP 45 DEGREES)
REGULATOR 25 OR 40 PSI
SCH 80 T.O.E. NIPPLE(2)
MAIN LINE PIPE & FITTINGS
BRICK SUPPORTS (4)
3/4" MINUS WASHED GRAVEL
FINISH GRADE
PVC SLIP UNIONS (2)
FINISH GRADE
3/4" MINUS WASHED GRAVEL
BRICK SUPPORTS (4)
MAIN LINE PIPE & FITTINGS
SCH 80 T.O.E. NIPPLE
STANDARD VALVE BOX
WATERPROOF CONNECTORS (2)
18-24" COILED WIRE
REMOTE CONTROL VALVE MODEL
ICV-101G ACCU-SYNC-ADJ
PVC SLIP UNIONS
MODEL ACC-XX00-PED
3/4" POWER CONDUIT: SIZE,
TYPE, DEPTH PER LOCAL CODE
GROUND WIRE CONDUIT,
MIN. 1 1/2". GROUND PER
ASIC GUIDELINES
PEDESTAL BASE: CONCRETE
OR PREFABRICATED
FINISH GRADE
CONDUIT FOR CONTROL WIRES
HUNTER ACC CONTROLLER
CONDUIT FROM SOLAR SYNC SENSOR TO CONTROLLER OR TO
A POINT 12" BELOW GRADE
SUITABLE POST, POLE, GUTTER MOUNT. MOUNT IN LOCATION THAT
MAXIMIZES DIRECT SUNLIGHT, OPEN TO RAINFALL AND OUT OF
SPRINKLER SPRAY PATTERN
MODEL: SOLAR SYNC SENSOR
CONTROLLER POWER SOURCE
CONDUIT FOR VALVE CONTROL WIRE AND SOLAR SYNC COMMUNICATION
WIRE
COMMUNICATION WIRE, 18-2(WIRE TYPE TO MEET INSTALLATION CODE
REQUIREMENTS), FROM MODULE TO SENSOR. MAXIMUM TOTAL WIRE
DISTANCE, 200 FEET
MAX. 200' AWAY
FINISHED GRADE
TURF GRASS, GROUND
COVERS OR SHRUBS, SEE
PLANTING PLANS
AMENDED SOIL
ECO MAT SUBSURFACE
IRRIGATION
SITE SOIL
D
17mm DRIP LINE TUBING,
POLYPROPYLENE FLEECE
WRAPPED13.75" (35cm)
RECOMMENDED ECO MAT INSTALLATION DEPTH (D):
TURF AREAS:4" - 8"(10cm - 20cm)
GROUND COVER AREAS:8"(20cm)
SHRUB AREAS:12"(30CM)
OVERLAP MAT 4" (10cm)
13.75" (35cm)
4" (10cm)
SOD STAKE INSTALLED 8 FT
ON CENTER OVER TUBING
ICZ DRIP CONTROL ZONE
KIT, SIZE PER PLAN,
(1" KIT SHOWN)
ECO MAT SUBSURFACE
IRRIGATION MAT
PVC / TUBING CONNECTION
PVC SUPPLY HEADER, SIZE
AS REQUIRED, SEE PLANS
DRIP LINE TUBING, WRAPPED
IN POLYPROPYLENE FLEECE
PLD-BV, 17mm BARBED
SHUT-OFF / FLUSH VALVE
17mm PLD BLANK TUBING
AS DISCHARGE HEADER
PLD-TEE, 17mm BARB X
BARB X BARB TEE FITTING
D
NOTE: SEE CATALOG FOR ALLOWABLE LENGTH OF TUBING RUN (D).
PVC SUPPLY HEADER AND POLY DISCHARGE HEADER.
TURF GRASS, GROUND
COVERS OR SHRUBS, SEE
PLANTING PLANS
FINISHED GRADE
AMENDED SOIL
ECO MAT SUBSURFACE
IRRIGATION MAT WITH 17mm
DRIP LINE TUBING, WRAPPED
IN POLYPROPYLENE FLEECE
PLD-ELB, 17mm BARB X
BARB 90 DEGREE ELL
PLD-075, 17mm BARB X
3/4" MIPT ADAPTER, W/ 8"
OF BLANK PLD TUBING
SITE SOIL
PVC LATERAL LINE
PVC SST TEE FITTING,
LATERAL SIZE X 3/4"
D1
D2
D1 - ECO MAT DEPTH PER PLANS
D2 - 12" OR PER PLANS
OVERLAP ECO MAT
OVER CONNECTION AND
TO EDGE OF PLANTED
AND IRRIGATED
AREA
RECLAIMED CAP
OPTION INSTALLED
MODEL PROS-04-CV-R
SPRAY HEAD W/"CV"
FINISH GRADE
LATERAL TEE OR ELBOW
LATERAL PIPE
HUNTER SWING JOINT
2"-3" BARK MULCH, OR OTHER
TYPE OF MULCH AS SPECIFIED
ON LANDSCAPE PLAN.12" MIN.BURIAL18" MIN.BURIALLATERAL LINE
MAIN LINE
CONTROL WIRES
PLANTING TOPSOIL
FINISH GRADE, BURIAL
MEASUREMENT POINT.
TRENCH BACKFILL
NOTES:
1. TRENCH BACKFILL SHALL BE
FREE OF ROCK OR DEBRIS
GREATER THAN 1" IN SIZE.
2. DO NOT PLACE ROCK/DEBRIS
DIRECTLY AGAINST PIPE.
3. IN TRENCH W/ BOTH MAIN &
LATERAL LINES, OFFSET PIPES
6" IN HORIZONTAL DIRECTION
UNDISTURBED NATIVE SOIL24" MIN.BURIALSCH. 40 PVC SLEEVE,
FINISH GRADE, BURIAL
MEASUREMENT POINT.
TRENCH BACKFILL
NOTES:
1. TRENCH BACKFILL SHALL BE
FREE OF ROCK OR DEBRIS
GREATER THAN 1" IN SIZE.
2. DO NOT PLACE ROCK/DEBRIS
DIRECTLY AGAINST SLEEVE.
2(x) THE SIZE OF PIPE
WHICH IT CRADLES
2" DIA. SCH. 40 PVC
SLEEVE FOR ELEC. WIRES.
PAVEMENT, ASPHALT OR CONCRETE
COMPACTED CRUSHED
COMPACTED SUBGRADE
AGGREGATE PAVEMENT
SUBBASE
3. EXTEND SLEEVE 12" BEYOND
PAVEMENT EDGE OR AS REQ'D.
PER GRADE CONDITIONS.
BRICK SUPPORT (3)
MAIN LINE TEE OR ELL
FINISH GRADE
3/4" MINUS GRAVEL
PREFABRICATED SWING JOINT
10" ROUND VALVE BOX
MODEL HQ-44LRC-R
QUICK COUPLER VALVE
MAIN LINE PIPE
#4 REBAR W/SS HOSE CLAMPS
3/4-INCH WASHED GRAVEL
6-INCH MINIMUM DEPTH OF
VALVE BOX WITH COVER:
FINISH GRADE/TOP OF MULCH
FILTERED DRAIN VALVE:
BRICK (1 OF 2)
PVC LATERAL PIPE
PVC SCH 40 TEE
SCALE: NOT TO SCALE
DRIP CONTROL ZONE VALVE1 IRRIGATION DETAIL
SCALE: NOT TO SCALE
SPRAY CONTROL ZONE VALVE2 IRRIGATION DETAIL
SCALE: NOT TO SCALE
QUICK COUPLER VALVE3 IRRIGATION DETAIL
SCALE: NOT TO SCALE
DRAIN VALVE4
SCALE: NOT TO SCALE
POP-UP SPRAY HEAD5
SCALE: NOT TO SCALE
IRRIGATION CONTROLLER6 IRRIGATION DETAIL
SCALE: NOT TO SCALE
SOLAR SYNC7 IRRIGATION DETAIL
SCALE: NOT TO SCALE
(NOT USED)8
SCALE: NOT TO SCALE
TRENCH SECTIONS10
SCALE: NOT TO SCALE
ECO-MAT11 IRRIGATION DETAIL
PLANSECTIONCONNECTION
L6.0L4.0
SITE PLANNING
LANDSCAPE
ARCHITECTURE
A S P E N
CONTACT: PAUL J. DIX
ASPEN DESIGN GROUP
P.O. BOX 2394
ISSAQUAH, WA 98027
(425) 292-9845 (PHONE)
PAUL J. DIX
CERTIFICATE NO. 620
STATE OF WASHINGTON
REGISTERED LANDSCAPE ARCHITECT
Revi
e
w
O
n
l
y
L6.0L4.0
L6.0L4.0L6.0L4.0
L6.0L4.0 L6.0L4.0
L6.0L4.0 L6.0L4.0 L6.0L4.0 L6.0L4.0
DocuSign Envelope ID: 44E7B13B-E61D-42E2-9010-CB07930C65F3