R-403830
A A B A C A D A E A F A G H w U z w ry w LL w ry 0 00 O lit A W z O I- z W ry LL O A, u LEGEND: GENERAL ELECTRICAL NOTES: O INSTRUMENTATION AND CONTROL DEVICE. O CONNECTION POINT TO EQUIPMENT SPECIFIED. FURNISHED AND INSTALLED UNDER OTHER DIVISIONS OR CONTRACTS. RACEWAY, CONDUCTOR AND CONNECTION IN THIS DIVISION. [WXXYYZ] LOW VOLTAGE CONDUIT AND/OR CABLE DESIGNATION, SEE SCHEDULE W=P POWER W=T TELEPHONE YYY=000.999 W=S SIGNAL W=F FIRE Z=A THROUGH Z (OPTIONAL) W=C CONTROL XX= AREACODE W=PC POWER AND CONTROL MAJOR ELECTRICAL COMPONENT OR DEVICE - NAME 704-MCC01 OR IDENTIFYING SYMBOL AS SHOWN. PNL ® BRANCH CIRCUIT PANELBOARD X 5 MOTOR, SQUIRREL CAGE INDUCTION, HORSEPOWER INDICATED OR ABOVE GRADE CONDUIT AND CONDUCTORS — — OR/�fG CONCEALED OR UNDERGROUND CONDUIT AND CONDUCTORS I ATr- ALL UNMARKED HOME RUNS CONSIST OF TWO #12AWG CU CONDUCTORS IN CONDUIT. RUNS MARKED WITH CROSSHATCHES INDICATE NUMBER OF CONDUCTORS. CROSSHATCH WITH SUBSCRIPT "G" INDICATES GREEN GROUND WIRE. MINIMUM CONDUIT SIZE SHALL BE 3/4" FOR EXPOSED CONDUIT AND 1" FOR CONCEALED OR UNDERGROUND CONDUIT. CROSSHATCHES WITH BAR INDICATE #1OAWG CU 3 G CONDUCTORS. MINIMUM CONDUIT SIZE SHALL BE 3/4" FOR EXPOSED CONDUIT AND 1" FOR CONCEALED OR UNDERGROUND CONDUIT. CONDUIT DOWN CONDUIT UP ,.I., 120/240V 15 KVA 1 PH TD OR TC IXTDR Ir TO GROUND TRANSFORMER, SECONDARY VOLTAGES, PHASE AND RATING INDICATED AS APPLICABLE TIME DELAY RELAY CONTACT (TIME ACTION INDICATED) REMOTE DEVICE, WITH TERMINAL POINTS SHOWN COIL, LETTER SYMBOL OR ABBREVIATIONS INDICATE TYPE OF DEVICE 1. PROVIDE ELECTRICAL INSTALLATION IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE, LOCAL CODES, ORDINANCES. 2. PROVIDE ITEMS NECESSARY TO COMPLETE ELECTRICAL SYSTEMS. THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC AND DO NOT NECESSARILY SHOW EVERY CONDUIT, BOX, CONDUCTOR OR SIMILAR ITEMS FOR A COMPLETE INSTALLATION. 3. VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT ACCESS CLEARANCES CAN BE MET. 4. CONDUITS PASSING THRU BUILDING CONSTRUCTION EXPANSION JOINTS SHALL HAVE APPROVED EXPANSION FITTINGS, PROPERLY BONDED. 5. COORDINATE CONNECTIONS OF MECHANICAL EQUIPMENT WITH MECHANICAL AND CONTROLS CONTRACTORS PRIOR TO ROUGH -IN. 6. GROUND ALL ELECTRICAL DEVICES, MOTORS, METAL FRAMING, ETC., IN ACCORDANCE WITH NEC ARTICLE 250. PROVIDE A SEPARATE GREEN EQUIPMENT GROUNDING CONDUCTOR IN EACH RACEWAY. INDICATING LIGHT - LETTER INDICATES COLOR A A - AMBER G - GREEN ABBREVIATIONS: B - BLUE R - RED C - CLEAR W - WHITE ATS AUTOMATIC TRANSFER SWITCH INDICATING LIGHT - NEON CU COPPER G GROUND OIT OPERATOR INTERFACE TERMINAL PLC PROGRAMMABLE LOGIC CONTROLLER SWITCH, SINGLE POLE, SINGLE THROW (SPST) PMD POWER MONITORING DEVICE PSE PUGET SOUND ENERGY SE SERVICE ENTRANCE SSS SOLID SOFT STARTER TYP TYPICAL SWITCH, SINGLE POLE, DOUBLE THROW (SPDT) UPS UNINTERRUPTIBLE POWER SUPPLY VFD VARIABLE FREQUENCY DRIVE O A H SELECTOR SWITCH XOO OOX X = CLOSED CONTACT XOX O = OPEN CONTACT H=HAND A = AUTO TRANSFORMER, SECONDARY VOLTAGES, PHASE 120V AND RATING INDICATED AS APPLICABLE. -:1 CONDUIT, STUBBED AND CAPPED AS SHOWN 0 0 PUSH-BUTTON SWITCH, MOMENTARY CONTACT, NORMALLY OPEN JO OR HH GENERAL CONTROL OR WIRING DEVICE. LETTER SYMBOLS OR ABBREVIATIONS INDICATE TYPE OF DEVICE CONTACT - NORMALLY OPEN 10HP ® RECEPTACLE, SPECIAL PURPOSE - HP RATED HP AS INDICATED CONTACT - NORMALLY CLOSED 30 NONFUSED DISCONNECT SWITCH, SIZE INDICATED, 3 POLE UNLESS INDICATED OTHERWISE. 2 PUSH-BUTTON SWITCH, MOMENTARY CONTACT, ® VARIABLE SPEED DRIVE NORMALLY CLOSED VSDOOXX000 CONTACTOR - NORMALLY OPEN WITH NEMA SIZE PUSH TO TEST INDICATING LIGHT. 1 INDICATED AS APPLICABLE A LETTER INDICATES COLOR. OVERLOAD RELAY HEATER MAGNETIC STARTER WITH NEMA SIZE INDICATED KWH POWER METER CIRCUIT BREAKER, MAGNETIC TRIP ONLY, FRAME 100/M SIZE SHOWN, 3 POLE UNLESS INDICATED OTHERWISE. GENERATOR CIRCUIT BREAKER, THERMAL MAGNETIC TRIP SHOWN, 400 3 POLE UNLESS INDICATED OTHERWISE /2P=2 POLE. © GROUND BUS SWITCH - CURRENT RATING INDICATED, 3 POLE 100 UNLESS INDICATED OTHERWISE. 0 NEUTRAL BUS 1 FUSE - RATING INDICATED SA SURGE ARRESTOR 225 PMD 3-PHASE POWER MONITORING DEVICE, INCLUDING CURRENT TRANSFORMERS RIUNITY� NO REVISION DESCRIPTION BY I APVD DATE A V B V C PERMIT ISSUE DRAWING 11 JANUARY 2019 1 This document is released for the purpose of information exchange review and planning only under the authority of Richard E. Hensel, P.E. (Washington License No. 38424) on January, 2019. It is not to be used for bidding, permit or construction purposes. THIS SHEET HAS NOT BEEN REVIEWD AND HAS NOT BEEN APPROVED WITH THIS CIVIL CONSTRUCTION PERMIT PLAN SET. DESIGNED/DRAWN: R. HENSEL CHECKED: J. THOMAS PROJECT ENGINEER: B. SLIGER SCALE: NONE DESIGN APPROVAL: B. ISAAC FACILITY NUMBER: PROJECT ACCEPTANCE: CONTRACT NO: M. DARBY C01307C18 DEPARTMENT OF NATURAL RESOURCES & PARKS WASTEWATER TREATMENT DIVISION EASTSIDE INTERCEPTOR SECTION 2 REHABILITATION - PHASE II ELECTRICAL KJ n9Cy SYMBOLS AND ABBREVIATIONS CIO N O O 00 Aj H H T_ W U) Q z O Q J_ m Q W N z O U W U) 171000 I - a_ W U W I- z W 0 U) I- U) Q W z O Q O ILL z U W O z O I- DATE: JAN UARY 2019 z W PROJECT FILE NO: 0/ 16-1123630 LL DRAWING NO: O E101 >- SHT NO / TOTAL REV 30 36 NO: 0 U 0 0 F V G i