HomeMy WebLinkAboutR-411411DRIP IRRIGATION EQUIPMENT SCHEDULE: DRIP DETAILS: Uz
z_ B D C-,
HUNTER IRRIGATION EQUIPMENT SHOWN IN SCHEDULE. TORO, RAINBIRD, WEATHERMATIC OR EQUIVALENT IRRIGATION EQUIPMENT MAYBE SUBSTITUTED, "" z
WITH LANDSCAPE ARCHITECT'S WRITTEN APPROVAL ONLY. .•<LU
'`
CL
SYMBOL DESCRIPTION REMOTE CONTROL VALVE WITH DIS'b O E... 0
FILTER AND PRV ■
O BRASS GATE VALVE - RuB Ball Valve - Model S951F43 (Round Handle) - SIZE TO FIT MAINLINE [ '—J
BFP I BACKFLOW ASSEMBLY - FEBCO LF850 (SIZE TO MATCH METER) Z mail
l— 4330 N Lexington St
WATER METER (SEE CIVIL PLAN - COORDINATE POC WITH CONSTRUCTION MANAGER) V UW Tacoma, WA 98407
RAIN SENSOR -HUNTER RAIN-CLIK-WIRELESS RAIN SENSOR (WRC-INT) OR EQUAL, SEE GENERAL NOTE C PVC OR POLY SUPPLY HEADER NOTES: � ~'
I LU = location
1. SEE PLANS & LEGEND Q Q ne U 455B St Helens Ave CONTROLLER - HUNTER PCC 6 ZONE - PCC-600i (X-CORE, PRO-C, PCC, I -CORE, ACC) I I FINISH GRADE Q Tacoma, WA 98402
CLASS 200 PVC LATERAL LINE PIPING, SIZE PER PLAN I START CONNECTION MALE ADAPTER FOR ALL DIMENSIONSLU
COMPACTED AND Techline LATERAL Q t.253.272.4848
2" SCHEDULE 40 PVC MAIN LINE I I SUBGRADE SPACING U f.253.276.0132
CLASS 200 PVC SLEEVE 2X PIPE DIAMETER, 4" MIN.
Techline TUBING 2. RATIO OF Techline LAT- z www.bradtree.com
Not Shown #14 AWG TYPE OF CONTROL WIRE, RED = SIGNAL, WHITE = COMMON, ORANGE= SPARE I I DRIPLINE (TYP.) I PVC HEADER ERALS TO START CON- info@bradtree.com I
P.S.I. GPH Techline TEE (TYP.) NECTIONS IS SHOWN AT
HUNTER DRIP LINE - PLD-04-12 (12" EMITTER SPACING x 12" ROW SPACING) 15-50 .40 I r� AREA PERIMETER 2:1, BUT MAY VARY PER ado�%/�
Techline START HYDRAULIC DEMAND ON
HUNTER DRIP LINE -PLD-04-18 (18" EMITTER SPACING x 18" ROW SPACING) 15-50 .40 I I
AIR/VACUUM RELIEF VALVE (PLUMBS CONNECTION (TYP.) START CONNECTION.
HUNTER DRIP LINE - BLANK TUBING (HEADER) - PDL-BLNK-18 I I EACH HIGH POINT ( )
) SEE PLANS &LEGEND STATE OF
1" CLASS 200 PVC SUB -MAIN LINE FOR DISTRIBUTION TO HEADERS WASHINGTON
( ) I I REGISTERED
LANDSCAPE_ RCHITECT
AR AIR/VACUUM RELIEF VALVE (PLACED AT HIGH POINT OF ZONE) AR -
De LINE FLUSHING VALVE I I .
thl
a Brad ey
0la DRIP ZONE CONTROL KIT - PCZ-101-40 (INCLUDES CONTROL VALVE, 40 PSI PRESSURE REGULATOR & FILTER) I BLANK TUBING (CENTERED ON MOUE` I o.
BERM) ,
Op TREE DRIPLINE CENTRIC RING
NOTE: DESIGN ASSUMES 50 PSI STATIC WATER PRESSURE AT POINT OF CONNECTION AND 30 PSI DESIGNED PRESSURE
IRRIGATION REQUIREMENTS:
GENERAL NOTES
A. IRRIGATION DESIGN ASSUMES XX PSI STATIC WATER PRESSURE IS
AVAILABLE ON SITE. VERIFY STATIC WATER PRESSURE IN FIELD PRIOR TO
CONSTRUCTION. NOTIFY LANDSCAPE ARCHITECT IF STATIC WATER PRESSURE
IS LESS THAN 55 PSI. IRRIGATION DESIGN IS BASED ON 30 PSI.
B. USE 4" POP-UP HEADS WITHIN ALL LAWN AREAS AND 6" POP-UP HEADS
WITHIN ALL SHRUB AREAS. 12" POP-UP HEADS ARE OPTIONAL IN SHRUB BEDS
WITH OWNERS REQUEST.
C. RAIN SENSOR TO BE INSTALLED ON SOUTH OR WEST SIDE OF BUILDING,
AT A MINIMUM OF 8 FEET ABOVE GRADE WHERE SENSOR IS FREE FROM
VANDALISM, TREE CANOPIES, BUILDING OVER HANGS OR OTHER STRUCTURAL /
NATURAL RAIN IMPEDIMENTS. COORDINATE LOCATION WITH CONSTRUCTION
MANAGER.
IRRIGATION NOTES
1. PLAN IS DIAGRAMMATIC. VERIFY LOCATION OF STRUCTURES, UTILITIES
AND OTHER SITE ELEMENTS PRIOR TO COMMENCING WORK. NOTIFY
PROJECT MANAGER OF ANY CONFLICTS.
2. CONTRACTOR TO TEST EXISTING WATER PRESSURE AN PROVIDE WRITTEN
REPORT TO PROJECT MANAGER PRIOR TO COMMENCING WORK.
3. REVIEW ALL IRRIGATION DETAILS PRIOR TO COMMENCING WORK.
4. REFER TO EQUIPMENT SCHEDULE FOR ALL IRRIGATION HEAD TYPES AND
EQUIPMENT.
5. PROVIDE 2 (TWO) SPARE WIRES FROM THE CONTROLLER TO THE
FURTHEST VALVE LOCATIONS FOR FUTURE EXPANSION.
6. STAKE ALL VALVE BOX LOCATIONS FOR APPROVAL.
7. SET VALVE BOXES SQUARE TO ADJACENT BUILDING, CURB OR PAVING.
8. ALL IRRIGATION UNDER ROADS, WALKS, PARKING AREAS OR OTHER PAVED
SURFACES SHALL BE SLEEVED. SLEEVES SHALL BE 2 (TWO) TIMES THE
DIAMETER OF THE INSERTED PIPE OR AS INDICATED.
9. ALL PIPING IS DIAGRAMMATIC. PIPING SHOWN WITHIN PAVING OR
ADJACENT / PARALLEL TO PLANTED AREAS ARE INTENDED TO BE PLACED
WITHIN PLANTING BEDS WHERE POSSIBLE. ALL MATERIAL TO BE INSTALLED
ON OWNER'S PROPERTY.
10. MAKE ANY AND ALL REQUIRED ADJUSTMENTS TO THE IRRIGATION PLAN
TO ASSURE COMPLETE AN ADEQUATE COVERAGE WITH MINIMUM OVER
SPRAY.
11. WHEN SLEEVING, PIPING OR HEAD LAYOUT IS REQUIRED IN R.O.W.,
CONTRACTOR TO COORDINATE LOCATION WITH THE PROJECT ENGINEER
PRIOR TO CONSTRUCTION. INDICATE EXACT LOCATION OF SLEEVES AND
PIPING ON THE AS -BUILT DRAWINGS.
12. PLACE TRACE WIRE ON ALL IRRIGATION PIPING AT OWNER'S REQUEST.
13. LATERAL LINE SHALL HAVE MINIMUM 12" OF COVER AND MAINLINES A
MINIMUM OF 18" COVER.
14. PROVIDE MANUAL DRAINS AT ALL LOW POINT ON THE MAIN LINE AND
RECORD ACCURATELY ON AS -BUILT DRAWINGS.
15. LOCATE IRRIGATION BACK -FLOW PREVENTOR DOWN -STREAM OF SITE
WATER METER (WATER METER BY OTHERS). VERIFY LOCATION WITH
PROJECT MANAGER PRIOR TO COMMENCING WORK.
16. COORDINATE LOCATION OF CONTROLLER WITH PROJECT MANAGER.
INSTALL CONTROLLER AT 60" ABOVE (FINISH FLOOR / FINISH GRADE) ON
EXTERIOR WALL OF (BUILDING). PROVIDE A 110 GFI POWER OUTLET AT
CONTROLLER LOCATION FOR POWER SUPPLY. PROVIDE CONDUIT FROM
IRRIGATION CONTROLLER LOCATION TO OUTSIDE PLANTING BED. FLAG ALL
LOCATIONS.
VALVE KEY
o_
LLI
>
\
Q
N
>
c)
0
0
1
1"
16 MAX
DRIP
2
1"
16 MAX
DRIP
3
OPEN
OPEN
4
OPEN
OPEN
5
OPEN
OPEN
6
OPEN
OPEN
NOTES:
1. INSTALL ACCORDING TO MANUFACTURER'S SPECIFICATIONS
2. CONTRACTOR TO PRICE COMPLETE INSTALLATION UNLESS
OTHERWISE INFORMED.
End Feed Layout Detail
(NOT TO SCALE)
LF
NOTES TO DESIGNER
PVC OR POLY EXHAUST HEADER
PERIMETER LATERALS 2" TO 4" FRON
PLUMBED TO PVC OR POLY LINE FLU
VALVE "END FEED" LAYOUT
EDGE OF PAVING
SUPPLY HEADER
AIR/VACUUM RELIEF
VALVE AT HIGH POIN
REMOTE CONTROL
VALVE ASSEMBLY
Techline TUBING
ARRANGED TO COVER
TRIM AREA
EXHAUST HEADER
SPRINKLER ON
PVC LATERAL IN
IDEAL SPACING
PATTERN (TYP.)
EDGE OF TURF
LINE FLUSHING VALVE
1- IN THIS EXAMPLE, IDEAL SPACING IS MAINTAINED FOR THE SPRINKLER SYSTEM
W/ OUT DISTORTION, WHILE THE HEADS ARE SET AWAY FROM THE PAVING EDGE
TO AVOID OVERSPRAY
2- BLANK Techline TUBING IS USED TO JOIN THE LATERALS ACROSS THE HIGH SPOT
TO ENHANCE THE FUNCTION OF THE AIR/VACUUM RELIEF VALVE.
1. INSTALL ACCORDING TO MANUFACTURER'S SPECIFICATIONS
2. CONTRACTOR TO PRICE COMPLETE INSTALLATION UNLESS OTHERWISE INFORMED.
Tubing Detail
(NOT TO SCALE)
n
NOTES:
1. INSTALL ACCORDING TO MANUFACTURER'S SPECIFICATIONS
2. CONTRACTOR TO PRICE COMPLETE INSTALLATION UNLESS OTHERWISE INFORMED.
3. CONTACT NETAFIM FOR SPECIFICATIONS AND DETAILS BEFORE INSTALLATION.
Sub -Header Installation Detail
(NOT TO SCALE)
LANDSCAPE DRIPLINE TUBING:
HUNTER LANDSCAPE DRIPLINE
TIE DOWN STAKE
(QTY. AS REQUIRED)
TREE TRUNK
=SSION TEE
REQUIRED)
1/2-INCH POLYETHYLENE TUBING:
BLACK STRIPE TUBING
NOTE:
1. SEE "LOW -VOLUME LANDSCAPE IRRIGATION DESIGN MANUAL
(D39030D) FOR DRIPLINE EMITTER SPACING.
2. QUANTITY OF DRIPLINE RINGS, EMITTER SPACING AND FLOWS
ARE DEPENDANT ON TREE CANOPY SIZE.
Drip Around Tree Detail
(NOT TO SCALE)
CITY REVIEW - NOT FOR CONSTRUCTION
V I
w
M
Cz
z
VI
0
LL]
Ln
z
O
0-
u)
z
X
Lv
U
z
00
0,
w
=
w
Q
w
0
w
z
�
w
�
Q
w
LU
U
=
C!1
>
Q
V
>a
>
LU
�
Q
�
z
z
LIJ
m
V
Q
0�
O
z
O
<
Q�
V
(n
LL
M
REVISION
No.
Date
Ey
1 107 Jan 20% YSL
Rev. per Site
"Ian Changes
Scale
1" = 20'-0"
Designer Sheet No.
YSL
Project Manager IR-2
MFW
Principal
KBR
Date of 2 Sheets
16 April 2018
Phase
CD
Project No.
3.8oi3