HomeMy WebLinkAboutzR-4114 Set:l I O qt I Q GENERAL SITE NOTES: 1. THE CONTRACTOR SHALL OBTAIN AND HAVE AVAILABLE COPIES OF THE APPLICABLE GOVERNING AGENCY STANDARDS AT THE JOB SITE DURING THE RELATED CONSTRUCTION OPERATIONS. 2. CONTRACTOR SHALL ASSURE THAT ALL NECESSARY PERMITS HAVE BEEN OBTAINED PRIOR TO COMMENCING WORK. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION AND DEPTH OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION WHETHER SHOWN ON THESE PLANS OR NOT. UTILITIES OTHER THAN THOSE SHOWN MAY EXIST ON THIS SITE. ONLY THOSE UTILITIES WITH EVIDENCE OF THEIR INSTALLATION VISIBLE AT GROUND SURFACE OR SHOWN ON RECORD DRAWING PROVIDED BY OTHERS ARE SHOWN HEREON. EXISTING UNDERGROUND UTILITY LOCATIONS SHOWN ARE APPROXIMATE ONLY AND ARE SUBJECT TO A DEGREE OF UNKNOWN VARIATION. SOME UNDERGROUND LOCATIONS SHOWN HEREON MAY HAVE BEEN TAKEN FROM PUBLIC RECORDS. BARGHAUSEN CONSULTING ENGINEERS, INC. ASSUMES NO LIABILITY FOR THE ACCURACY OF PUBLIC RECORDS OR RECORDS OF OTHERS. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT BARGHAUSEN CONSULTING ENGINEERS, INC., TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. 4. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REVIEW ALL OF THE DRAWINGS AND SPECIFICATIONS ASSOCIATED WITH THE PROJECT WORK SCOPE PRIOR TO THE INITIATION OF CONSTRUCTION. SHOULD THE CONTRACTOR FIND A CONFLICT WITH THE DOCUMENTS RELATIVE TO THE SPECIFICATIONS OR THE RELATIVE CODES, IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PROJECT ENGINEER OF RECORD IN WRITING PRIOR TO THE START OF CONSTRUCTION. FAILURE BY THE CONTRACTOR TO NOTIFY THE PROJECT ENGINEER SHALL CONSTITUTE ACCEPTANCE OF FULL RESPONSIBILITY BY THE CONTRACTOR TO COMPLETE THE SCOPE OF WORK AS DEFINED BY THE DRAWINGS AND IN FULL COMPLIANCE WITH LOCAL REGULATIONS AND CODES. 5. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE APPROPRIATE UTILITIES INVOLVED PRIOR TO CONSTRUCTION. 6. INSPECTION OF SITE WORK WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE GOVERNING JURISDICTION. INSPECTION 0F PRIVATE FACILITIES WILL BE ACCOMPLISHED BY A REPRESENTATIVE 0F THE OWNER. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 7. PRIOR TO ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY THE CONTRACTOR SHALL CONTACT THE AGENCY AND/OR UTILITY INSPECTION PERSONNEL AND ARRANGE ANY REQUIRED PRE -CONSTRUCTION MEETING(S). CONTRACTOR SHALL PROVIDE ONE WEEK MIN. ADVANCE NOTIFICATION TO OWNER, FIELD ENGINEER AND ENGINEER OF PRE -CONSTRUCTION MEETINGS. 8. THE CONTRACTOR IS RESPONSIBLE FOR WORKER AND SITE SAFETY AND SHALL COMPLY WITH THE LATEST OSHA STANDARDS AND REGULATIONS, OR ANY OTHER AGENCY HAVING JURISDICTION FOR EXCAVATION AND TRENCHING PROCEDURES. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE "MEANS AND METHODS" REQUIRED TO MEET THE INTENT AND PERFORMANCE CRITERIA OF OSHA, AS WELL AS ANY OTHER ENTITY THAT HAS JURISDICTION FOR EXCAVATION AND/OR TRENCHING PROCEDURES. 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACTOR. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE AT LEAST ONE FLAGGER FOR EACH LANE OF TRAFFIC AFFECTED. 10. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT ALL ADJACENT PUBLIC AND PRIVATE PROPERTIES AT ALL TIMES DURING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF ALL EXISTING UTILITY SERVICES THAT ARE TO REMAIN OPERATIONAL WITHIN THE CONSTRUCTION AREA WHETHER SHOWN OR NOT SHOWN ON THE PLANS. 11. TWO (2) COPIES OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. ONE (1) SET WITH RECORDS OF AS -BUILT INFORMATION SHALL BE SUBMITTED TO BARGHAUSEN CONSULTING ENGINEERS, INC. AT COMPLETION OF PROJECT. 12. CONTRACTOR SHALL OBTAIN SERVICES OF A LICENSED LAND SURVEYOR TO STAKE HORIZONTAL CONTROL FOR ALL NEW IMPROVEMENTS. STAKING CONTROL SHALL BE TAKEN FROM ELECTRONIC PLAN FILES PROVIDED BY BARGHAUSEN CONSULTING ENGINEERS, INC. 13. CONTRACTOR SHALL REQUEST FROM BARGHAUSEN CONSULTING ENGINEERS INC., PRIOR TO ANY CONSTRUCTION STAKING OR CONSTRUCTION WORK, A FORMAL CONSTRUCTION RELEASE PLAN SET OR SPECIFIC RELEASE IN WRITING. THE APPROVED AGENCY PERMIT DRAWINGS WILL NOT BE CONSIDERED CONSTRUCTION RELEASE PLANS BY BARGHAUSEN CONSULTING ENGINEERS, INC UNLESS BARGHAUSEN CONSULTING ENGINEERS, INC HAS GIVEN A FORMAL WRITTEN RELEASE OR ISSUED A CONSTRUCTION RELEASE PLAN SET. PROPOSED J Q cn CURB AND GUTTER BARRIER CURB CONCRETE ASPHALT <'I Q SAWCUT N 0 I CONTOUR o I STORM °' I SANITARY ' POWER 01 PAINT STRIPE 0 TYPE 1 CATCH BASIN co N Cm 01 01 0 N 0 0 0 0 N i LEGEND: EXISTING COVER SHEET FOR RENTON BROWN BEAR AUTO SENTRY ADDITION NE QUARTER OF SECTION 18, TOWNSHIP 23 NORTH, RANGE 5 EAST W.M. GEOTECHNICAL REPORT NOTES: CITY OF RENTON, KING COUNTY, WASHINGTON 1. THE FOLLOWING GEOTECHNICAL REPORTS FOR THE SITE SHALL BE CONSIDERED PART OF THESE CONSTRUCTION DOCUMENTS: SOILS REPORTS: GEOLOGIC HAZARD AREA REPORT JOB NUMBER: 2032.01 DATE: 07/27/2018 PREPARED BY: ZIPPERGEO GEOPROFESSIONAL CONSULTANTS 19019 36TH AVE WEST, SUITE E LYNNWOOD, WA 98036 2. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT ALL PROVISIONS OF THE SOILS REPORT FOR THE SITE BE OBSERVED AND COMPLIED WITH DURING ALL PHASES OF THE SITE PREPARATION, GRADING OPERATIONS, FOUNDATION, SLAB, AND PAVING CONSTRUCTION. 3. ANY PROVISIONS OF THE SOILS REPORT WHICH CONFLICT WITH INFORMATION SHOWN ELSEWHERE ON THESE DRAWINGS, OR WHICH REQUIRE FURTHER CLARIFICATION, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER FOR DETERMINATION. 4. A REPRESENTATIVE OF THE SOILS ENGINEER SHALL BE AVAILABLE TO OBSERVE AND APPROVE THE EARTHWORK OPERATIONS AND TO VERIFY FIELD CONDITIONS AS WORK PROCEEDS. THE SOILS ENGINEER SHALL SUBMIT FIELD REPORTS CERTIFYING THAT THE METHODS AND MATERIALS OF THE EARTHWORK OPERATIONS WERE IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE SOILS INVESTIGATION AND THAT THE WORK WAS PERFORMED TO HIS/HER SATISFACTION. 5. THE SOILS ENGINEER SHOULD BE NOTIFIED AT LEAST FIVE (5) WORKING DAYS PRIOR TO ANY SITE CLEARING OR GRADING. CURB LUMINAIRE (LUM.) PAINT STRIPE YARD LIGHT [� L CONCRETE POWER METER p POWER POLE -0- CONTOUR 432-- JUNCTION BOX (AS NOTED) CATCH BASIN (CB) ❑ WATER _ _ _ _ _ W _ STORM MANHOLE (SDMH) STORM ---SD-- SANITARY SEWER MANHOLE (SSMH) 0 TYPE 1 CATCH BASIN ❑ CLEANOUT (AS NOTED) 0 GAS METER ❑o SANITARY - - SS- - GAS VALVE SS MANHOLE O WATER VALVE (WV) G FIRE HYDRANT(FH) IQ GAS CONNECTION (FDC) POWER OVERHEAD P (OHS WATER METER w POWER UNDERGROUND -P (UG)- SIGN GRAVEL/SAND (AS NOTED) DIRECTIONAL ARROW G _ ASPHALT BOLLARD BUILDING LINE CONIFEROUS TREE WATER LINE - W OH/UG TEL. LINE -T(xx)- DECIDUOUS TREE 6 58'33"W 173.58' G _- I A=2`31' \ ` R=565 �L=250 0 I \ ` EYJsn CAR WASH O SHEET INDEX 'y CIVIL: r C1.0 - COVER SHEET C2.0 - EXISTING CONDITIONS MAP C3.0 - TESC AND DEMOLITION PLAN ° C3.1 - TESC NOTES AND DETAILS ° 0 \ C4.0 - GRADING AND DRAINAGE SITE PLAN C5.0 - CONSTRUCTION DETAILS C5.1 - CONSTRUCTION NOTES ARCHITECTURAL: A1.1 - AUTO -SENTRY CANOPY A2.1 - AUTO -SENTRY CANOPY ELEVATIONS A3.1 - TRASH ENCLOSURE LANDSCAPING AND IRRIGATION: L-1 - LANDSCAPE PLAN L-2 - LANDSCAPE PLAN DETAILS IR-1 - IRRIGATION PLAN IR-2 - DRIP IRRIGATION SCHEDULE, NOTES AND DETAILS PROJECT INFORMATION: CALCULATED AREA: 21,913 +/- S.F. (0.50 AC +/-) PROPERTY ADDRESS: 77 RAINIER AVENUE S RENTON, WA 98057 PARCEL NUMBER: 182305-9131 HORIZONTAL DATUM: HORIZONTAL DATUM FOR THIS SURVEY IS NAD 83/2011 PER CITY OF RENTON. CITY OF RENTON CONTROL POINT NO. 884 WAS HELD FOR POSITION, AND A LINE BETWEEN SAID POINT NO. 884 AND CONTROL POINT NO. 205 WAS HELD FOR ROTATION, BEING SOUTH 88'00'59" EAST AS OBSERVED USING RTK GPS IN CONJUNCTION WITH THE W.S.R.N. (REFERENCE "EVERGREEN HARDIE SHORT PLAT K.C. REC. NO. 20060712900004) VERTICAL DATUM: LEGAL DESCRIPTION: VERTICAL DATUM FOR THIS SURVEY IS NAVD88 PER KING COUNTY. KING THAT PORTION OF SECTION 18, TOWNSHIP 23 NORTH, RANGE 5 EAST, COUNTY VERTICAL CONTROL POINT NO. R462 WAS HELD FOR ELEVATION, WILLAMETTE MERIDIAN, IN KING COUNTY WASHINGTON, DESCRIBED AS BEING 40.55'(NAVD88). FOLLOWS: CITY OF RENTON VERTICAL CONTROL MONUMENT NO. 2120. BEGINNING AT THE INTERSECTION OF A LINE DRAWN PARALLEL WITH AND 75 FEET WESTERLY, MEASURED RADIALLY FROM THE CENTERLINE OF FLOOD ZONE INFORMATION: PRIMARY STATE HIGHWAY NO. 5, SEATTLE TO RENTON, AND A LINE DESIGNATION OF FLOOD ZONE IS SCALED PER FEMA FIRM MAP DRAWN PARALLEL WITH 30 FEET NORTHEASTERLY, MEASURED AT RIGHT NUMBER 53033CO977F EFFECTIVE MAY 16, 1995 AND DOWNLOADED ANGLES FROM THE CENTERLINE OF FORMER PRIMARY STATE HIGHWAY FROM FEMA MAP SERVICE CENTER WEBSITE (HTTP://MSC.FIE MA. GOV): NO. 5, NOW 91ST PLACE SOUTH, ALSO KNOWN AS D.0 MITCHELL ROAD AND HAYES PLACE; ZONE X AREA DETERMINED TO BE OUTSIDE THE 500 YEAR FLOOD THENCE NORTHERLY ALONG SAID 75 FEET LINE A DISTANCE OF 250 PLAIN. FEET; THENCE SOUTH 81`55'00" WEST TO THE INTERSECTION WITH THE EASTERLY MARGIN OF 91ST PLACE SOUTH; THENCE SOUTHERLY ALONG THE EASTERLY MARGIN IS SAID 91ST PLACE OWNER CAR WASH ENTERPRISES, INC. 3977 LEARY WAY NORTHEAST SEATTLE, WASHINGTON 98107 CONTACT. JOE GIUSEFFI EMAIL: JOE.GIUSEFFI@BROWNBEAR.COM SURVEYOR BARGHAUSEN CONSULTING ENGINEERS, INC. 18215 72ND AVE. SOUTH KENT, WA 98032 TEL: (425) 251-6222 FAX: (425) 251-8782 CONTACT: BRIAN GILLOOLY, P.L.S. ENGINEER BARGHAUSEN CONSULTING ENGINEERS, INC. 18215 72ND AVE. SOUTH KENT, WA 98032 TEL: (425) 251-6222 FAX: (425) 251-8782 CONTACT: CHRIS JENSEN, P.E. ARCHITECT: BARGHAUSEN CONSULTING ENGINEERS, INC. 18215 72ND AVE. SOUTH KENT, WA 98032 TEL: (425) 251-6222 FAX: (425) 251-8782 CONTACT: DAN GOALWIN GEOTECHICAL ENGINEER: ZIPPERGEO GEOPROFESSIONAL CONSULTANTS 19019 36TH AVE WEST, SUITE E LYNNWOOD, WA 98036 TEL: (425) 582-9928 CONTACT: JAMES GEORGIS LANDSCAPE ARCHITECT: BRADLEY DESIGN GROUP, INC. 455E ST HELENS AVE TACOMA, WA 98402 TEL: (253) 272-4848 FAX: (253) 276-0132 CONTACT: KATHLEEN BRADLEY READER RENTON, WASHINGTON VICINITY MAP SCALE = 1:200 MONUMENT PROTECTION NOTE: CONTRACTOR SHALL FIELD LOCATE ALL MONUMENTS WITHIN THE AREA OF DISTURBANCE PRIOR TO CONSTRUCTION AND PROTECT FROM DISTURBANCE/DESTRUCTION TO THE MAXIMUM EXTENT FEASIBLE. IF IT IS NECESSARY TO REMOVE OR REPLACE A MONUMENT DURING CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION HAVING AUTHORITY (RCW 58.24.040) AND BE FULLY RESPONSIBLE FOR OBTAINING PERMITS FROM THE WASHINGTON STATE DEPARTMENT OF NATURAL RESOURCES PRIOR TO DISTURBANCE, DESTRUCTION, OR RELOCATION (WAC 332-120). APPLICATIONS MUST BE COMPLETED BY A REGISTERED LAND SURVEYOR AND MAY BE OBTAINED FROM THE WASHINGTON STATE DEPARTMENT OF NATURAL RESOURCES: WASHINGTON STATE DEPARTMENT OF NATURAL RESOURCES PUBLIC LAND SURVEY OFFICE 1111 WASHINGTON STREET S.E. P.O. BOX 47060 OLYMPIA, WASHINGTON 98504-7060 (206) 902-1190 UPON COMPLETION OF CONSTRUCTION, ALL MONUMENTS DISPLACED, REMOVED, OR DESTROYED THAT ARE ABLE TO BE REPLACED, SHALL BE REPLACED BY A REGISTERED LAND SURVEYOR AT THE COST AND AT THE DIRECTION OF THE CONTRACTOR PURSUANT TO THESE REGULATIONS. THE APPROPRIATE FORMS FOR REPLACEMENTS OF SAID MONUMENTATION SHALL ALSO BE THE RESPONSIBILITY OF THE CONTRACTOR. HORIZONTAL CONTROL NOTE: CONTRACTOR SHALL HAVE ALL PROPERTY LINES, CURB, SIDEWALK, STRUCTURES, CONCRETE PADS AND ANY OTHER ABOVE GROUND PERMANENT STRUCTURE DEPICTED ON THESE PLANS STAKED FOR CONSTRUCTION BY A LICENSED SURVEYOR. LICENSED SURVEYOR SHALL STAKE ALL ITEMS USING COORDINATE GEOMETRY (RECTIFIED TO SITE CONTROL) CONTAINED IN CAD DRAWING FILES PROVIDED BY BARGHAUSEN CONSULTING ENGINEERS, INC. IT IS THE CONTRACTOR'S RESPONSIBILITY TO RETRIEVE LATEST CAD FILES FROM BARGHAUSEN CONSULTING ENGINEERS INC., REFLECTING ANY ISSUED PLAN REVISIONS. BARGHAUSEN CONSULTING ENGINEERS SHALL IMMEDIATELY BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO THE START OF CONSTRUCTION. UTILITY CONFLICT NOTE: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 811 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL NOTIFY BARGHAUSEN CONSULTING ENGINEERS, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. SITE INFORMATION: PROPOSED SURFACE AREAS ONSITE NEW/REPLACED IMPERVIOUS AREA: 4,039 SF (0.09 AC) OFF -SITE NEW/REPLACED IMPERVIOUS AREA: 176 SF (0.00 AC) UTILITY/MAINTENANCE IMPROVEMENTS: 1,608 SF (0.04 AC) NEW PERVIOUS/LANDSCAPE AREA: 2,078 SF (0.05 AC) REPLACED IMPERVIOUS SURFACE DEFINITION PER THE 2017 CITY OF RENTON SURFACE WATER DESIGN MANUAL: SS�4NA���'\\ "ANY EXISTING IMPERVIOUS SURFACE ON THE PROJECT SITE THAT IS PROPOSED TO BE REMOVED AND RE-ESTABLISHED AS IMPERVIOUS SURFACE, EXCLUDING IMPERVIOUS SURFACE 6� SOUTH, 310.26 FEET TO THE POINT OF BEGINNING. REMOVED FOR THE SOLE PURPOSE OF INSTALLING UTILITIES OR PERFORMING MAINTENANCE _ 4114 01 SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON SURFACE WATER UTILITY ON UNDERGROUND INFRASTRUCTURE." ESTIMATED EARTHWORK QUANTITIES: CUT: 5 CY FILL: 78 CY NET: 73 CY (FILL) 0 AREA TO BE DISTURBED = 0.16 AC 0 EARTHWORK QUANTITIES ARE APPROXIMATE AND HIGHLY DEPENDANT ON SOIL CONDITIONS ENCOUNTERED DURING CONSTRUCTION. CONTRACTOR SHOULD PERFORM INDEPENDENT ESTIMATE FOR BIDDING. 2 REVISI❑NS PER CITY COMMENTS DATED 05/21/20 1 REVISIONS PER CITY COMMENTS NO. REVISION LRH CMS 6/18/20 CRJ LRH LRH 3/19/20 CRJ oKouEoe AEM BY DATE APPR CRJ jfarah 07/15/2020 Barghausen Know what's below. Consulting Engineers, Inc. Call before you dig. 18215 72nd Avenue South Dial 811 Kent, WA 98032 425.251.6222 barghausen.com 1�=40' '""'CITY 0F vR RENTON *a +o• M FaL I= Planning/Building/Public Works Dept. •Wum+a• am Ilpgl�grQ�r IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING REGIONAL FIRE AUTHORITY �N*o "R APPROVED o d p Scott Warlick 7/15/2020 ' m cthomas 07/15/2020 o"'F7RE.o CURRENT PLANNING _,p WASTEWATER UTILITY 0 Angelea Weihs 07/23/2019 Ann Fowler 07/15/2020 COVER SHEET FOR BROWN BEAR CARWASH 77 RAINIER AVE S RENTON, WA 98057 /10/2020 C1.0 . 7 \1 0 z a Cn U a Ln N 0 N 0 N 3 0 N / 0 N / 0 0 0 0 N / 1 LEGAL DESCRIPTION: THAT PORTION OF SECTION 18, TOWNSHIP 23 NORTH, RANGE 5 EAST, WILLAMETTE MERIDIAN, IN KING COUNTY WASHINGTON, DESCRIBED AS FOLLOWS: BEGINNING AT THE INTERSECTION OF A LINE DRAWN PARALLEL WITH AND 75 FEET WESTERLY, MEASURED RADIALLY FROM THE CENTERLINE OF PRIMARY STATE HIGHWAY NO. 5, SEATTLE TO RENTON, AND A LINE DRAWN PARALLEL WITH 30 FEET NORTHEASTERLY, MEASURED AT RIGHT ANGLES FROM THE CENTERLINE OF FORMER PRIMARY STATE HIGHWAY NO, 5, NOW 91ST PLACE SOUTH, ALSO KNOWN AS D.0 MITCHELL ROADAND HAYES PLACE; THENCE NORTHERLY ALONG SAID 75 FEET LINE A DISTANCE OF 250 FEET; THENCE SOUTH 81'55'00"WEST TO THE INTERSECTION WITH THE EASTERLY MARGIN OF 91ST PLACE SOUTH; THENCE SOUTHERLY ALONG THE EASTERLY MARGIN IS SAID 91ST PLACE SOUTH, 310.26 FEET TO THE POINT OF BEGINNING. SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON TITLE INSURANCE: ALL TITLE INFORMATION SHOWN ON THIS MAP HAS BEEN EXTRACTED FROM CHICAGO TITLE INSURANCE COMPANY COMMITMENT NO. 191735-SC, DATED MAY 14, 2019 AT 12:OOAM, INCLUDING APPURTENANT EASEMENTS AND ADJOINING DEEDS FOR UNPLATTED LOTS, IF ANY. IN PREPARING THIS MAP, BARGHAUSEN CONSULTING ENGINEERS, INC. HAS CONDUCTED NO INDEPENDENT TITLE SEARCH NOR IS BARGHAUSEN CONSULTING ENGINEERS, INC. AWARE OF ANY TITLE ISSUES AFFECTING THE SURVEYED PROPERTY OTHER THAN THOSE SHOWN ON THE MAP AND DISCLOSED BY THE REFERENCED CHICAGO TITLE INSURANCE COMPANY COMMITMENT. BARGHAUSEN CONSULTING ENGINEERS, INC. HAS RELIED WHOLLY ON CHICAGO TITLE INSURANCE COMPANY'S REPRESENTATIONS OF THE TITLE'S CONDITION TO PREPARE THIS SURVEY AND THEREFORE BARGHAUSEN CONSULTING ENGINEERS, INC. QUALIFIES THE MAP'S ACCURACY AND COMPLETENESS TO THAT EXTENT. HORIZONTAL DATUM: HORIZONTAL DATUM FOR THIS SURVEY IS NAD 83/2011 PER CITY OF RENTON. CITY OF RENTON CONTROL POINT NO. 884 WAS HELD FOR POSITION, AND A LINE BETWEEN SAID POINT NO. 884 AND CONTROL POINT NO. 205 WAS HELD FOR ROTATION, BEING SOUTH 88'00'59" EAST AS OBSERVED USING RTK GPS IN CONJUNCTION WITH THE W.S.R.N. (REFERENCE "EVERGREEN HARDIE SHORT PLAT K.C. REC. NO. 20060712900004) VERTICAL DATUM: VERTICAL DATUM FOR THIS SURVEY IS NAVD88 PER KING COUNTY. KING COUNTY VERTICAL CONTROL POINT NO. R462 WAS HELD FOR ELEVATION, BEING 40.55'(NAVD88) LOT AREA: 21,913 +/- S.F. (0.50 AC +/-) ADDRESS: 103 RAINIER AVE S, RENTON, WA 98057 TAX PARCEL NUMBER: 182305-9131 DATE OF SURVEY: THIS SURVEY REPRESENTS VISIBLE PHYSICAL IMPROVEMENT CONDITIONS EXISTING ON MAY 1, 2019. ALL SURVEY CONTROL INDICATED AS "FOUND" WAS RECOVERED FOR THIS PROJECT IN MAY OF 2019. SURVEYOR'S NOTES: • ALL DISTANCES SHOWN HEREON ARE GROUND MEASUREMENTS IN U.S. SURVEY FEET. • THE BOUNDARY CORNERS AND LINES DEPICTED ON THIS MAP REPRESENT DEED LINES ONLY, AND DON'T PURPORT TO SHOW OWNERSHIP LINES THAT MAY OTHERWISE BE DETERMINED BY A COURT OF LAW. NO GUARANTEE OF OWNERSHIP IS EXPRESSED OR IMPLIED. • UNDERGROUND UTILITIES AND FEATURES DEPICTED HEREON ARE BASED ON FIELD OBSERVATION, MARKINGS, DEVELOPMENT PLANS, AND/OR AVAILABLE RECORD DOCUMENTS ONLY. THE TRUE LOCATION, NATURE AND/OR EXISTENCE OF BELOW GROUND FEATURES, DETECTED OR UNDETECTED, SHOULD BE VERIFIED. • THE LEGAL DESCRIPTION AND SPECIAL EXCEPTIONS SHOWN HEREON ARE PER THE ABOVE REFERENCED TITLE REPORT UNLESS OTHERWISE NOTED. • THIS SURVEY HAS DEPICTED ALL VISIBLE OCCUPATIONAL INDICATORS (IE. FENCE LINES, BUILDINGS, WALLS, ETC. - SEE MAP FOR PARTICULARS) PER W.A.C. 332-130. LINES OF OCCUPATION, AS DEPICTED, MAY INDICATE AREAS OF POTENTIAL CLAIMS OF UNWRITTEN OWNERSHIP. THIS SURVEY HAS ONLY DEPICTED THE RELATIONSHIP BETWEEN LINES OF OCCUPATION AND DEEDED LINES OF RECORD. NO RESOLUTION OF OWNERSHIP BASED ON UNWRITTEN RIGHTS HAS BEEN MADE BY THIS SURVEY OR BY ANY PERSONNEL OF BARGHAUSEN CONSULTING ENGINEERS, INC. • THIS IS A FIELD TRAVERSE SURVEY. SPECTRA PRECISION FOCUS 30, TOPCON GR5 GPS AND SPECTRA PRECISION RANGER DATA COLLECTOR WAS USED TO MEASURE THE ANGULAR AND DISTANCE RELATIONSHIPS BETWEEN THE CONTROLLING MONUMENTATION AS SHOWN. CLOSURE RATIOS OF THE TRAVERSE MET OR EXCEEDED THOSE SPECIFIED IN W.A.C. 332-130-090. ALL INSTRUMENTS AND EQUIPMENT HAVE BEEN MAINTAINED IN ADJUSTMENT ACCORDING TO MANUFACTURERS' SPECIFICATIONS AND USED BY APPROPRIATELY TRAINED PERSONNEL. SPECIAL EXCEPTIONS: (PER ABOVE REFERENCED TITLE REPORT) 1. EXCEPTIONS AND RESERVATIONS CONTAINED IN DEED WHEREBY THE GRANTOR EXCEPTS AND RESERVES ALL OIL, GASES, COAL, ORES, MINERALS, FOSSILS, ETC., AND THE RIGHT OF ENTRY FOR OPENING, DEVELOPING AND WORKING THE SAME AND PROVIDING THAT SUCH RIGHTS SHALL NOT BE EXERCISED UNTIL PROVISION HAS BEEN MADE FOR FULL PAYMENT OF ALL DAMAGES SUSTAINED BY REASON OF SUCH ENTRY GRANTOR: STATE OF WASHINGTON RECORDING NO.: 5956425 RIGHT OF THE STATE OF WASHINGTON OR ITS SUCCESSORS, SUBJECT TO PAYMENT OF COMPENSATION, TO ACQUIRE RIGHTS OF WAY FOR PRIVATE RAILROADS, SKID ROADS, FLUMES, CANALS, WATER COURSES OR OTHER EASEMENTS FOR TRANSPORTING AND MOVING TIMBER, STONE, MINERALS AND OTHER PRODUCTS FROM THIS AND OTHER LAND, AS RESERVED IN ABOVE -REFERENCED DEED. (NOT SURVEY RELATED) 2. COVENANTS, CONDITIONS, RESTRICTIONS, RECITALS, RESERVATIONS, EASEMENTS, EASEMENT PROVISIONS, DEDICATIONS, BUILDING SETBACK LINES, NOTES, STATEMENTS, AND OTHER MATTERS, IF ANY, BUT OMITTING ANY COVENANTS OR RESTRICTIONS, IF ANY, INCLUDING BUT NOT LIMITED TO THOSE BASED UPON RACE, COLOR, RELIGION, SEX, SEXUAL ORIENTATION, FAMILIAL STATUS, MARITAL STATUS, DISABILITY, HANDICAP, NATIONAL ORIGIN, ANCESTRY, OR SOURCE OF INCOME, AS SET FORTH IN APPLICABLE STATE OR FEDERAL LAWS, EXCEPT TO THE EXTENT THAT SAID COVENANT OR RESTRICTION IS PERMITTED BY APPLICABLE LAW, AS SET FORTH ON SURVEY: RECORDING NO: 9310209004 (SHOWN HEREON) DOCUMENT DEPICTS LOT CONFIGURATION AND SURROUNDING ROADS. 3. COVENANTS, CONDITIONS, RESTRICTIONS, RECITALS, RESERVATIONS, EASEMENTS, EASEMENT PROVISIONS, DEDICATIONS, BUILDING SETBACK LINES, NOTES, STATEMENTS, AND OTHER MATTERS, IF ANY, BUT OMITTING ANY COVENANTS OR RESTRICTIONS, IF ANY, INCLUDING BUT NOT LIMITED TO THOSE BASED UPON RACE, COLOR, RELIGION, SEX, SEXUAL ORIENTATION, FAMILIAL STATUS, MARITAL STATUS, DISABILITY, HANDICAP, NATIONAL ORIGIN, ANCESTRY, OR SOURCE OF INCOME, AS SET FORTH IN APPLICABLE STATE OR FEDERAL LAWS, EXCEPT TO THE EXTENT THAT SAID COVENANT OR RESTRICTION IS PERMITTED BY APPLICABLE LAW, AS SET FORTH ON DECLARATION OF LOT COMBINATION LLC 18-000287-LC: RECORDING NO: 20180629000436 (SHOWN HEREON) DOCUMENT DEPICTS CURRENT LOT CONFIGURATION RENTO, ss .fs \ , ss \ \ 52.55 52.3� `\\�Sn m.\\\\\�\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ EXISTING CONDITIONS MAP FOR ►ROWN BEAR AUTO SENTRY . NE QUARTER OF SECTION 187 TOWNSHIP 23 NORTH, RANGE 5 EAST W.M. CITY OF RENTON, KING COUNTY, WASHINGTON SSMH RIM=49.81' 4. GENERAL AND SPECIAL TAXES AND CHARGES, PAYABLE FEBRUARY 15, DELINQUENT IF FIRST HALF UNPAID ON MAY 1, SECOND HALF DELINQUENT IF UNPAID ON NOVEMBER 1 OF THE TAX YEAR (AMOUNTS DO NOT INCLUDE INTEREST AND PENALTIES): YEAR: 2019 TAX ACCOUNT NO.: 182305-9131 LEVY CODE: 2100 ASSESSED VALUE -LAND: $368,000.00 ASSESSED VALUE -IMPROVEMENTS: $428,600.00 GENERAL AND SPECIAL TAXES BILLED: $9,032.35 PAID: $4,516.18 UNPAID: $4,516.17 (NOT SURVEY RELATED) 5. PURCHASE OPTION AND RIGHT OF FIRST REFUSAL AND THE TERMS AND CONDITIONS THEREOF: GRANTED TO: CHEVRON U.S.A., INC., A PENNSYLVANIA CORPORATION RECORDING DATE: JULY 25, 2007 RECORDING NO.: 20070725000865 (NOT SURVEY RELATED) 6. A DEED OF TRUST TO SECURE AN INDEBTEDNESS IN THE AMOUNT SHOWN BELOW, AMOUNT: $25,000,000.00 DATE: MARCH 31, 2008 TRUSTOR/GRANTOR: CAR WASH ENTERPRISES, INC., A WASHINGTON CORPORATION TRUSTEE: PRLAP, INC. BENEFICIARY: BANK OF AMERICA, N.A. RECORDING DATE: MAY 23, 2008 RECORDING NO.: 20080523001534 AFFECTS: INCLUDES OTHER PROPERTY FOR INFORMATIONAL PURPOSES ONLY: THE FOLLOWING MAY BE USED AS AN ABBREVIATED LEGAL DESCRIPTION ON THE DOCUMENTS TO BE RECORDED, PER AMENDED RCW 65.04.045. SAID ABBREVIATED LEGAL DESCRIPTION IS NOT A SUBSTITUTE FOR A COMPLETE LEGAL DESCRIPTION WITHIN THE BODY OF THE DOCUMENT: PORTION SECTION 18-23-5, RENTON LOT LINE ELIMINATION LUA18-000287 TAX ACCOUNT NO.: 182305-9131-01 THE LEGAL DESCRIPTION IN THIS CERTIFICATE IS BASED ON INFORMATION PROVIDED WITH THE APPLICATION AND THE PUBLIC RECORDS. ALL PARTIES MUST NOTIFY THE TITLE INSURANCE COMPANY IF THE DESCRIPTION DOES NOT CONFORM TO THEIR EXPECTATIONS (NOT SURVEY RELATED) SURVEYOR'S CERTIFICATION: TO: CAR WASH ENTERPRISES, INC., A WASHINGTON CORPORATION THIS IS TO CERTIFY THAT THIS MAP OR PLAT AND THE SURVEY ON WHICH IT IS BASED WERE MADE IN ACCORDANCE WITH THE 2016 MINIMUM STANDARD DETAIL REQUIREMENTS FOR ALTA/NSPS LAND TITLE SURVEYS, JOINTLY ESTABLISHED AND ADOPTED BY ALTA AND NSPS, AND INCLUDES ITEMS 2, 3, 5, 7(A), 7(B)(1), 7(C), 8, 9, 11, 13, 16 AND 18 OF TABLE A THEREOF. THE FIELDWORK WAS COMPLETED ON MAY 1, 2019. DATE OF PLAT OR MAP: MAY 6, 2019 MAY 29, 2019 R. L. HILLEBRAND, P.L.S. DATE WASHINGTON REGISTRATION NO. 37530 2 IREVISI❑NS PER CITY COMMENTS DATED 05/21/20 1 REVISI❑NS PER CITY COMMENTS NO. REVISION POWER \ VAULT 6" PVC CULV WSW =52.29' 12" CNC CULV WSW = 52.34' POWER VAULT SSMH RIM=51.78' 8" DI NW IE=44.63' 8" DI SE IE=44.40' CMS 6/18/20 LRH 3/19/20 BY I DATE SDMH T2 °s ! RIM=43.60' : fie. a 1' 4 s 8" CNC W IE=39.73' 51.31 18" CNC E IE=38.13' .33 8" CNC SW IE=39.98' 47 12" CNC S IE=39.30' O ss\ UER SDMH ssf` RIM=44.55' 8" CNC N IE=42.33' \ . s" 12" CNC N IE= SIGN 3.84 4.48 12" CNC NW IE=40.93' \ 8" CNC SW IE=40.83' 4 8" CNC S IE=41.68' 8" CNC S IE=41.02' CB STD GIRT T1 6., RIM=43.64' 4 8" CNC NE IE=41.72' SSMH RIM=44.36' UNKN N 50 6 8" DI NW IE=38.38' VA T , }1 8" DI S IE=38.26' IpH TEL JB X 6.. .2 CB STD GIRT T1 RIM=44.66' N 6" DI SE IE=43.73' \ -SS ASS SS �O SS SSMH ss j-45.50 `�'44, RIM=47.54' ss-s�ssl. 8" DI SE IE=41.90' 8" DI NW IE=42.01' CB STD GIRT LRH CRJ LRH CRJ aKo�o� AEM APPR CRJ T1 RIM=44.66' 6" CNC NW IE=42.99' 6" CNC W IE=42.86' 6" CNC NE IE=42.99' Know what's below. Call before you dig. Dial 811 1�=30' *aOt" a ftaam AccommIr x�R SSMH RIM=37.62' 12" DI N IE=30.40' 3764 8" DI SW IE=30.53' 8" DI E IE=30.12' 3738 SIGN .55 1° .36 HYDRANT 36.65 3. SSMH RIM=38.56' 8" DI W IE=28.71' 10 12" PVC E IE=28.26' - SS - 8" PVC S IE=28.86' CB STD GIRT 7.55 RIM=37.19' .593fi�" CNC E IE=35.62' 635 (TO CHANNEL) .37 16 TEL JBOX UNKNOWN VAULT LOT LIGHT (TYP) �_ 39.14 CB STD GIRT T1 RIM=36.74' 8 CNC E IE=35.09' 56 CNC S IE=35.09' 0 CB STD GIRT T1 RIM=38.79' 6" CNC N IE=37.18' 4,.',�4 QC W IE=37.23' 43.23 CB STD GIRT T1 RIM=41.58' 8" CNC E IE=40.12' (TO CHANNEL) -TEL RISER 44(DESTROYED) CAN - BUS 453s TOP WATER i METER '•`�,ii, UNKNOWN VAULT 46.23 TEL RISER Barghausen Consulting Engineers, Inc. 18215 72nd Avenue South Kent, WA 98032 425.251.6222 barghausen.com vR CITY OF RENTON Planning/Building/Public Works Dept. LEGEND (NOTE: NOT ALL SYMBOLS MAY APPEAR ON THE MAP) &� SURVEY MONUMENT (AS NOTED) SECTION CORNER (AS NOTED) • SET REBAR/CAP (LS#45789) 0 FOUND REBAR/CAP (AS NOTED) ❑ SET 2"X2" HUB/TACK LINE STAKE MAG/WASHER OR LEAD/TACK (AS NOTED) BENCHMARK LUMINAIRE (LUM.) *0 YARD LIGHT 0 ORNAMENTAL LIGHT o 14� TRAFFIC SIGNAL LIGHTS POWER METER -0- POWER POLE ® JUNCTION BOX (AS NOTED) ® TELEPHONE MANHOLE ❑ CATCH BASIN (CB) ® STORM MANHOLE (SDMH) O SANITARY SEWER MANHOLE (SSMH) o CLEANOUT (AS NOTED) FGAS METER V GAS VALVE �Dv4y pQ WATER VALVE (WV) Ir FAUCET FIRE HYDRANT(FH) / CONNECTION(FDC) ® WATER MANHOLE ® WATER METER BLOW -OFF / AIRVAC MONITOR WELL SIGN 1> IRRIGATION SPRINKLER DIRECTIONAL ARROW ( HANDICAP x CHAIN LINK FENCE ii WOOD FENCE ❑ HOGWIRE FENCE -*** SILT FENCE p METAL/IRON FENCE GUARD RAIL/CABLE FENCE - w - w - WATER LINE -G-G- GAS LINE STEAM- STEAM LINE T(xx) TELEPHONE LINE (OH) OR (UG) -P(xx)- POWER LINE (OH) OR (UG) -SD - STORM LINE - SS SEWER LINE C:mC3a ROCKERY CIE= KEYSTONE WALL O DECIDUOUS TREE CONIFEROUS TREE TREE DRIPLINE °a a CONCRETE GRAVEL/SAND (AS NOTED) ASPHALT LL /� BUILDING LINE ABBREVIATIONS (R#) REFERENCE SURVEYS (OH) OVERHEAD (UG) UNDERGROUND (TYP) TYPICAL (C) CALCULATED (M) MEASURED REFERENCE SURVEYS EVERGREEN HARDIE AVENUE SHORT PLAT K.C. REC. NO. 90060712900004 RECORD OF SURVEY K.0 REC. NO. 931020900 RECORD OF SURVEY K.0 REC. NO. 8202189010 R - 411401 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Scott Warlick 7/15/2020 CURRENT PLANNING 4ngelea Weihs 07/23/2019 1/10/2020 EXISTING CONDITIONS MAP nkerAft FOR mm BROWN BEAR CARWASH °'""m'' 77 RAINIER AVE S RENTON, WA 98057 sat C2.0°" 7 :l T - DEMOLITION CALLOUTS: 1 1. DEMOLISH EXISTING ON -SITE CONCRETE AND/OR ASPHALT AND DISPOSE OF O OFFSITE. qt 2. DEMOLISH EXISTING FUEL CANOPY, FUEL DISPENSERS, FUEL ISLANDS, AND Q 1 APPURTENANCES AND DISPOSE OF OFFSITE (TYPICAL). W 3. DEMOLISH EXISTING UNDERGROUND STORAGE TANK (UST) AND FUEL DISPENSER H CONCRETE SLAB AND DISPOSE OFFSITE.TANKS SHOULD BE DECOMMISSIONED, REMOVED AND DISPOSED OF PER APPLICABLE DEPARTMENT OF ECOLOGY AND CITY OF RENTON/KING COUNTY REQUIREMENTS. SEE DEEP EXCAVATION NOTE THIS SHEET. 4. CONTRACTOR TO PROVIDE SEPARATE SHORING PERMIT AND DESIGN AS NECESSARY TO REMOVE EXISTING UST SYSTEM. PER GEOTECH REPORT, VISUAL MONITORING OF TANK EXCAVATION IS RECOMMENDED AND TEMPORARY SHORING IS IMPLEMENTED UPON OBSERVATION OF UNSTABLE SLOPES. 5. REMOVE EXISTING CHANNELIZATION MARKERS (TYPICAL) AND DISPOSE OFFSITE. 6. CONTRACTOR TO COORDINATE RELOCATION AND PROTECTION OF EXISTING BEAR STATUES WITH OWNER PRIOR TO DEMOLITION. 7. REMOVE EXISTING ONSITE CURB AND DISPOSE OFFSITE. 8. PROTECT EXISTING CURB TO REMAIN. 9. EXISTING CARWASH TO REMAIN AND BE PROTECTED. 10. APPROXIMATE SAWCUT LIMITS (TYPICAL). 11. CONTRACTOR TO OBTAIN PERMITS AS NECESSARY TO REMOVE EXISTING OIL/WATER SEPARATOR AND DISPOSE OFFSITE. 12. REMOVE EXISTING CATCH BASIN AND DISPOSE OFFSITE. PLUG EXISTING STORM DRAIN. EXISTING STORM DRAIN TO REMAIN AND BE PROTECTED. 13. CONFIRM EXTENTS OF EXISTING UNDERGROUND POWER REMOVAL. CONTRACTOR TO CONFIRM POWER SERVICE TO NEW LOT LIGHTS, AND AUTO SENTRY STRUCTURE PRIOR TO CONSTRUCTION. CONSULT OWNER FOR ELECTRICAL DESIGN AND CONDUIT ROUTING PRIOR TO CONSTRUCTION. 14. REMOVE EXISTING FENCE AND DISPOSE OFFSITE. 15. REMOVE EXISTING LIGHT AND DISPOSE OFF -SITE. 16. PROTECT EXISTING LIGHT TO REMAIN. 17. PROTECT EXISTING VAC STATIONS TO REMAIN. 18. REMOVE EXISTING OFF -SITE ASPHALT. CONTRACTOR TO CONFIRM SEPARATE ROW PERMIT FOR WORK OFF -SITE AS NECESSARY. 19. PROTECT EXISTING ASPHALT/CONCRETE PAVEMENT TO REMAIN. 20. PROTECT EXISTING TREE TO REMAIN. CONTRACTOR TO INSTALL PERIMETER PROTECTION AROUND EXISTING TREES FOR DURATION OF PROJECT. 21. REMOVE EXISTING SIGN AND APPURTENANCES AND DISPOSE OFF -SITE. 22. PROTECT EXISTING STORM PIPE TO REMAIN. 23. ABANDON EXISTING STORM PIPE TO EXTENTS SHOWN. SEE C4.0 FOR LOCATION OF PROPOSED STORM PIPE. 24. PROTECT EXISTING CATCH BASIN TO REMAIN. SEDIMENT CONTROL NOTE: CONTRACTOR TO SLOPE SITE AND MAINTAIN SEDIMENT CONTROL BMP'S TO ENSURE THAT THE SITE CONTAINS ALL SURFACE STORM WATER RUNOFF AND SEDIMENT. THE PROPERTY SHALL BE BOUND BY SILT FENCE AS NECESSARY. ADDITIONAL TESC CONTROL MAY BE REQUIRED. WHAT HAS BEEN DEPICTED ON THESE PLANS IS ONLY THE MINIMUM REQUIRED TO CONTAIN SILT LADEN STORM WATER. CONTRACTOR MAY BE REQUIRED TO MODIFY OR IMPLEMENT ADDITIONAL TESC CONTROLS THROUGHOUT CONSTRUCTION. 0 UTILITY CONFLICT NOTE: U THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, Q AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY _ POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 811 AND o THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED 7, PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, CO THE CONTRACTOR SHALL NOTIFY BARGHAUSEN CONSULTING ENGINEERS, INC. TO 3 RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. z w TESC/DEMO LEGEND: co 0 N 0, Cm CATCH BASIN PROTECTION i � PERIMETER PROTECTION CN LIMITS OF DISTURBANCE 0 0 o ---------------------- SAWCUT LINE a CONSTRUCTION FENCE TESC AND DEMOLITION PLAN FOR RENTON BROWN BEAR AUTO SENTRY ADDITION NE QUARTER OF SECTION 18, TOWNSHIP 23 NORTH, RANGE 5 EAST W.M. CITY OF RENTON, KING COUNTY, WASHINGTON 3 1p 20 1 6 \\ �� 3 20 20 73. 3 ."a 4 • ,� , 1 7 Ci 7 I «•• o r= I \ 15 1 o O ,1010 \ 14 / � 5 \ I �O ++� 1' c \\ \ \\ \ J' 4 12 1 \ .' C \\ \ \\ 1 r \\ \\ \ 10 i 1 0 t MR s \00, 24 4 ` \ \ \ r / \ « w * 22 5 13 s « 000 I \ w '00 \\\ ss \ \ \ �� % \\\ \ \ 19 18 \ J / \\\ \ss \ � l,s� \ 'o \ •i I \\ \s \� \ \ .� ; : \ 6 \\\\\\s \\\ \ 16 / d e . 17 0 \\ \ss \ � \ � °• A ° � A \ PIUGI 'C °•° 17 o \\\o rs \\ \\ \I SDSD N I j � 1 I , 0 � I 1 N I 0 o 11 N o I It, P(`'jG) ---� P(UG) V '� rn 0 VI N D I I ' I � N N 0 EP.I SS SS 0 1 ' c . 15y o � I 4 /1 N � / N I � I 1 I 0 / I � I O �= I /o 11 0 � I 1 I I I I I 24 ° O 17 1 I o• I I I \I\ \ o s \ \ \ I I I > O TESC CALLOUTS' ° \ \ \ I �'` �' a C I ' 1. TEMPORARY CONSTRUCTION FENCE 6' HIGH CHAIN LINK OR °:..I SIMILAR). FIELD VERIFY AND CONFIRM EXACT LOCATION WITH °' ° L 0 \ ° °• OWNER. SEE DETAIL 3/C3.1. \ \\\ \ ° -i 2. TEMPORARY SITE ACCESS GATE (6' HIGH CHAIN LINK WITH LOCKING DEVICE). FIELD VERIFY AND CONFIRM EXACT LOCATION \ \ O WITH OWNER. 3. CONTRACTOR TO INSTALL PERIMETER PROTECTION (TEMPORARY \ 1 \ ss\ss \\ \\ SILT FENCE - MIRAFI 10OX, OR EQUIVALENT) AROUND \ \ \ \Ln PERIMETER OF SITE AS REQUIRED PER COR STANDARD PLAN \1 GJ 216.30 TO PREVENT SILT -LADEN RUNOFF FROM LEAVING SITE, \ ° AND AS DIRECTED BY CITY INSPECTOR. SEE DETAIL 1 /C3.1. N \ ss \ \ \ \ \ \ ArGCJ \ 1 4. CONTRACTOR TO INSTALL M D STORRAIN INLET PROTECTION AT C ss \ \\ ALL CATCH BASIN INLET LOCATIONS AS REQUIRED PER COR \ GCJ \ STANDARD PLAN 214.00 TO PREVENT TO PREVENT SILT -LADEN \ss WATER FROM ENTERING STORM DRAINAGE SYSTEM, AND AS DIRECTED BY CITY INSPECTOR. SEE DETAIL 2/C3.1. \ ss h 5. CONSTRUCTION STAGING AREA. CONTRACTOR TO USE THIS AREA s FOR TEMPORARY STOCKPILE STORAGE AND CONCRETE WASHOUT. \ \ \Ss AREA SHALL BE USED TO FUEL EQUIPMENT AND TEMPORARY \ �� STORAGE OF FUEL. CONTRACTOR SHALL KEEP SPILL KITS ON -HAND IN CASE OF EMERGENCY. ADJUST SIZE AND LOCATION \ ss OF AREA AS NEEDED DURING CONSTRUCTION. \ \Ss 6. APPROXIMATE LIMITS OF DISTURBANCE. CONCRETE TO BE REMOVED ASPHALT TO BE REMOVED CURB TO BE REMOVED UTILITY NOTE: ALL UNDERGROUND UTILITIES AND SERVICES TO REMAIN UNDISTURBED UNLESS OTHERWISE SHOWN. ALL CLEANOUTS AND OTHER UTILITIES WITHIN REPLACED ASPHALT OR CONCRETE TO BE RAISED TO FINISHED GRADE. 2 REVISI❑NS PER CITY COMMENTS DATED 05/21/20 1 REVISIONS PER CITY COMMENTS NO. REVISION LRH pow CMS 6/18/20 CRJ LRH LRH 3/19/20 CRJ * ook AEM BY DATE APPR CRJ :: l 2 d= � R=56 . L=2 .01' 4 1 I 0 a \ ✓ i 42 e J O w4- I Know what's below. Call before you dig. Dial 811 1"=20' *a dem Y UNU I= ifW*Ado• am Ilpgl�grQ�r 1 I 1 1 DEMOLITION PERMIT: A DEMOLITION PERMIT FROM THE DEPARTMENT OF ECOLOGY SHALL BE REQUIRED FOR THIS PROJECT. EROSION CONTROL NOTES: 1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION OF EROSION AND SEDIMENT CONTROL BMPS WHEN RAIN IS IMMINENT. 2. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE AUTHORITY HAVING JURISDICTION AFTER EACH RUN-OFF PRODUCING RAINFALL. 3. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE AUTHORITY HAVING JURISDICTION DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 4. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED. 5. CONTRACTOR TO IMPLEMENT SLOPE STABILIZATION MEASURES AS NECESSARY FOR EXPOSED SLOPES DURING CONSTRUCTION. DEMOLITION NOTES: 1. ALL PAVEMENTS, SLABS, GROUND COVER, UTILITIES, ETC., INSIDE LIMITS OF DISTURBANCE SHALL BE REMOVED UNLESS OTHERWISE SHOWN ON THE PLANS. 2. CONTRACTOR SHALL CONTACT AND COORDINATE WITH THE VARIOUS UTILITY COMPANIES ON REQUESTING DISCONNECTIONS, REMOVALS AND/OR RELOCATION OF EXISTING SERVICE AS NECESSARY. 3. CONTRACTOR SHALL ASSURE THAT ALL NECESSARY PERMITS AND CONSTRUCTION APPROVALS HAVE BEEN OBTAINED PRIOR TO COMMENCING WORK. 4. CONTRACTOR SHALL REPLACE ALL EXISTING CURB, PAVEMENT AND/OR LANDSCAPING DAMAGED AS A RESULT OF CONSTRUCTION ACTIVITY. 5. CONTRACTOR SHALL, PRIOR TO CONSTRUCTION OR REMOVAL OF IMPROVEMENTS, FIELD VERIFY AND CONFIRM LIMITS OF DEMOLITION AS WELL AS EXISTING UTILITIES AND IMPROVEMENTS TO REMAIN. CONSTRUCTION SEQUENCE: 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY, A PRECONSTRUCTION MEETING MUST BE HELD BETWEEN THE APPLICANT, APPLICANT'S CONSTRUCTION REPRESENTATIVE, AND THE CITY OF RENTON. 2. POTHOLE / UTILITY LOCATES. 3. FLAG CLEARING LIMITS. 4. INSTALL DESIGNATED CONSTRUCTION ENTRANCE AS NEEDED. 5. INSTALL FILTER FABRIC FENCE AS INDICATED ON PLAN. 6. INSTALL ONSITE/OFFSITE CATCH BASIN PROTECTION. ' 7. POTHOLE EX. UTILITIES FOR VERTICAL AND HORIZONTAL LOCATIONS ' 8. CLEAR AND GRUB AREAS OF THE SITE TO BE ROUGH GRADED OR FILLED. 9. CLEAN STORM DRAINAGE SYSTEM, ON AND OFF -SITE, OF ALL SEDIMENT AND DEBRIS AFTER CONSTRUCTION. 10. REMOVE TEMPORARY EROSION CONTROL MEASURES WHEN SITE IS COMPLETELY STABILIZED. DEEP EXCAVATION NOTE: TANK EXCAVATIONS SHALL BE PER OSHA REQUIREMENTS. TANK EXCAVATIONS THAT REQUIRE SHORING SHALL BE ENGINEERED AND PERMITTED SEPARATELY AND SHALL BE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR. Barghausen Consulting Engineers, Inc. 18215 72nd Avenue South Kent, WA 98032 425.251.6222 barghausen.com CITY OF RENTON Planning/Building/Public Works Dept. G ��SW�EN p 47671 �`FS FC I S i ro II`L R-411401. IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING ` •• -r Scott Warlick 7/15/2020 CURRENT PLANNING Angelea Weihs 07/23/2019 1 /10/2020 FOR mm BROWN BEAR CARWASH 77 RAINIER AVE S RENTON, WA 98057 I`t C3.d' 7 ., 0 z J Q N U a 0 N CD N z w I 0 N cm / 0 N / 0 0 0 CD / DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 2"x2" 14 GAUGE WIRE, OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED - FILTER FABRIC 00 TESC NOTES AND DETAILS to N FOR � RENTON BROWN BEAR AUTO SENTRY ADDITION 0 N NE QUARTER OF SECTION 18, TOWNSHIP 23 NORTH, RANGE 5 EAST W.M. U 2' MIN. --i�------------I�-- I �' 6' MAX. 12"MIN. POST SPACING MAY BE INCREASED I TO 8' IF WIRE BACKING IS USED I I 4"x4"MIN. TRENCH BACKFILL TRENCH WITH NATIVE SOIL OR 3/4" TO 1-1/2" WASHED GRAVEL 2"x4" WOOD POSTS, STEEL FENCE POSTS. OR EQUIVALENT (TYP.) NOTES: 1. CONDITIONS OF USE 1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. 1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE. ADS (ASTM D4751) 30-100 SIEVE SIZE (0.60-0.15mm) FOR SILT FILM 50-100 SIEVE SIZE (0.30-0.15mm) FOR OTHER FABRICS WATER PERMITTIVITY (ASTM D4491) 0.02 SEC' MINIMUM GRAB TENSILE STRENGTH (ASTM D4632) 180 LBS. MIN. FOR EXTRA STRENGTH FABRIC 100 LBS. MIN. FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION (ASTM D4632) 30 % MAX. (WOVEN ULTRAVIOLET RESISTANCE (ASTM D4355) 70 % MIN. STANDARD STRENGTWFABRIC REQUIRES WIRE BACKING TO INCREASE THE-STRENI� III TH�FENCE. WIRE BACWNG OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER PENCE 2.3 WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2HA V' ZA* IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4"X4" TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 2.5. FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE. 3. MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY. 3.2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY IMUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS 11607HE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS<<REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT. 3.4. SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH: 3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) PUBLIC WORKS STD. PLAN - 214.00 UR PRo D DEPARTMENT SILT FENCE GAZ 9/28/2018 Public Works Administrator DATE SILT FENCE c3.1 SCALE: NOT TO SCALE 4 C /mll ^ M ! Al %IAKII rPM \.VIV -INt- i L ULV\,F\ MIN 80 LBS :45 Al TYP) IN r E\VViUL OL\iVE\L M1 irq.nrviLwl AROUND ENTIRE FENCE PANEL TEMPORARY CONSTRUCTION FENCE SCALE: NOT TO SCALE CITY OF RENTON, KING COUNTY, WASHINGTON DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 DRAINAGE GRATE GRATEFRAME C= SEDIMENT AND DEBRIS FILTERED WATER - SECTION V-MW DRAINAGE GRATE (RECTANGULAR GRATE SHOWN) BELOW INLET GRATE DEVICE 5" MAX. TRIM OVERFLOW BYPASS 1 BELOW INLET GRATE DEVICE RETRIEVAL SYSTEM�(TY�)1 OVERFLOW BYPASS (TYP.) ISOMETRIC VIEW NOTES: 1. PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS, WI- DO-OPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 2. INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3. THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4. SIZE THE BELOW INLET GRATE DEVICE (BIGD) FOR THE STORMWATER STRUCTURE IT WILL SERVICE. Si,i 17HE BIGD SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM (OVERFLOW BYPASS). 8' THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL. 7. PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8-01.3(15). 8. ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 216"30 moo,® PUBLIC WORKS APPR ED: DEPARTMENT CATCH BASIN INSERT GAZ 9/28/2018 Public Works Administraor DATE 2 IREVISI❑NS PER CITY COMMENTS DATED 05/21/20 1 REVISIONS PER CITY COMMENTS NO. REVISION 2 CATCH BASIN INSERT C3.1 SCALE: NOT TO SCALE 0 Know what's below. p Call before you dig. 1 Dial 811 11191111444%> IFIR FRP. LRH CMS 6/18/20 CRJ pow LRH LRH 3/19/20 CRJ AEM m qu Ilm • W *A +Ion BY DATE APPR I 0840m CRJ I= Accommair :45 AP DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE EROSION AND SEDIMENT CONTROL (ESC) PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE ESC STANDARD PLAN NOTES. 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR. 2. THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION STORMWATER GENERAL PERMIT, IF IT IS REQUIRED FOR THE PROJECT. THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT. 3. THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION COMMENCEMENT TO POST -PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS. 4. THE BOUNDARIES OF THE CLEARING LIMITS, SENSITIVE AREAS AND THEIR BUFFERS, AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS PRESCRIBED ON THE PLANS) SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/ESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION. 5. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK -OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED OFFSITE, PUBLIC ROADS SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET -WEATHER, AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING WATERS OF THE STATE. 6. WASHOUT FROM CONCRETE TR4LCKVSHALL BE PERFORMED OFF -SITE -OR IN DESIGNATED -CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE TRUCKS ONTO THE GROUND, OR TO STORM DRAINS OR OPEN DITCHES..BN-SITE DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE WASHOUT AREAS. 7. ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAN4.�LEARING AND/OR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. ALL ESC BMPS SHALL BE REMOVED AFTER CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR ON -SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT, ENHANCEMENT, AND REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT. 8. ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY. 9. THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. 10. APPROVAL OF THIS PLAN IS FOR ESC ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR STORMWATER FACILITIES. 11. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 12. ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1 ST THROUGH APRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON (MAY 1ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.) IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM. 13. WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER 1ST AND APRIL 30TH, UNLESS OTHERWISE APPROVED BY THE CITY. 14. ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS. 15. THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT. INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY. 16. BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216.30 SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING CONDITION. 17. AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 2/3 OF THE CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM. 18. ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC BMPS AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE TEMPORARY FACILITY IS TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE TEMPORARY FACILITY SHALL BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY. 19. AREAS DESIGNATED ON THE PLAN(S) CONTAINING EXISTING STORMWATER FACILITIES"OR ON -SITE BMPS (AMENDED SOILS, BIORETENTION, PERMEABLE PAVEMENT, ETC.) SHALL BE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUCTION, 20. PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW. 21. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT -LADEN WATER FROM LEAVING THE PROJECT SITE, ALL ESC BMPS SHALL BE REMOVED, AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND ON -SITE BMPS SHALL BE RESTORED TO THEIR FULLY FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A MINIMUM, DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINAL APPROVAL. MULCH WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER 1ST. 22. ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE CONSTRUCTED TO,SERVE AS RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 268.00 • UBLIC WORKS EROSION AND SEDIMENT CONTROL PPR PRI DEPARTMENT GAZ 9/28/2018 STANDARD PLAN NOTES PO4C Works Administrator DATE :45 AI\ G vo�-\s BEN P o Z - p 47671 �`FS FC I S i S/0NA L R - 411401 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Barghausen DEVELOPMENT ENGINEERING ` } Consulting Engineers, Inc. Scott Warlick 7/15/2020 18215 72nd Avenue South Kent, WA98032 CURRENT PLANNING 425.251.6222 barghausen.com Angelea Weihs 07/23/2019 07 .08mrX00110„I AOF%k1 /10/2020 CITY OF nhoomw RENTON FOR BROWN BEAR CARWASH Planning/Building/Public Works Dept. 77 RAINIER AVE S RENTON, WA 98057c3.�'� 7 :l 0 z J Cn U a N CN 0 N 0 N N Q 0 0 N Cm 0) 0 N 0 0 0 N i SANITARY SEWER TABLE SSCB # 1, W/ TRAFFIC RATED LID W/ VERTICAL TEE FOR OIL/WATER SEPARATION RIM = 39.36 IE=36.86 (6.00" OUT SE) CATCH BASIN GRADING AND DRAINAGE SITE PLAN FOR RENTON BROWN BEAR AUTO SENTRY ADDITION 01 MEASUREMENT FROM NORTHEAST PROPERTY CORNER TO NE QUARTER OF SECTION 18, TOWNSHIP 23 NORTH, RANGE 5 EAST W.M. CENTER OF THE NORTH EASTERN CANOPY COLUMN. CANOPY CITY OF RENTON, KING COUNTY, WASHINGTON AS SHOWN IS PARALLEL TO NORTH PROPERTY LINE. TABLE CB #1, TYPE 1, W/STANDARD GRATE RIM = 37.11 IE=34.61 (8" E) IE=34.61 (6" SE) A CB #2, TYPE 1, W/ SOLID LOCKING TRAFFIC RATED LID RIM = 38.16 IE=35.78 (6" NW) IE=35.78± ME (6" S) �1 I •`..�+•.••:� :. \ \o I:.� % 38.67 8 \ 0.8 0 1 38.7 •••�•••.•.'.'. 38.80' 38.56 38.45± ME 38.89 \ 9.39 TP `39.50 •. .•••. -. . \ 1 \• `::•�:•.._�. .••••. G� \ 0 •` 39.39 .:.'.;y' % `••.•:•:.•.:.�. 38.58 35.19' ••.•.3$. • .`. '` col \ 39.39• .�SSCB 1 i 38.42± ME \ ••.. �G 39.47' :. .:.'.'. .••-+.�_ �••-.•••• 39.50 •'39.40'••.:' I \\ \ `-•:•+..••• \ . .O'�,� .•+'. .•. . . ��:. .� ; 2 37.29± ME 39.12 37.20± ME 450 DRAINAGE STRUCTURE NOTES \ ` o�., .. •. • • •.... •. • .. ` , 39.29 2 LF 8 DI SD @ 0.50% 4 - • - 1. PROPOSED CATCH BASIN. PROPOSED CONNECTION \ �P. �' �`:- . 39.87 o�g ' ' TO EXISTING STROM LINE. CONTRACTOR SHALL \ . q p� - _� 39.60 2 LF �8" DI SD @ 0.50% 2 37.16± PROVIDE FITTING/ADAPTERS AS NECESSARY TO \ �G .��`� -`-` -• '• 0.0 01,�iCB 1MAKE CONNECTION AS SHOWN. IT MAY BE..�'�0 39.49 ,i o 00 NECESSARY TO ADJUST POINT OF CONNECTION TO v\ \`, G�S� 39.92± ME �. • • • • 6 `� 39.60 f ' EXISTING STORM. NOTIFY BARGHAUSEN CONSULTING \ O��\ ` 40.16 �. ��° 37.11 3 1 ENGINEERS OF ANY DISCREPANCIES AND/OR \ DEVIATIONS FROM WHAT IS SHOWN. \ \ p 39.87 2. FUELING AREA OIL/WATER SEPARATOR PER CITY O ' MEASUREMENT FROM NORTHEAST PROPERTY CORNER TO CENTER OF THE NORTH WESTERN CANOPY COLUMN. CANOPY 80.15 AS SHOWN IS PARALLEL TO NORTH PROPERTY LINE. I / g8.15' 6) 14 �.. -. PROPERTY LINE C�lggg38'33 _ 350'-` :•`_i.-• . .`.`.'-` . . . . . . :.i.:.`.+ •.-. .-.f"`.'-��•-.'. -•--. ct°r.. . . . . . • . . . ..•... - .-... -.•+• . . . 16 r �•\.-:.•�.-.�-. •W- :�•:.,,-+•.- ••.•_ •-. .••-.--•. .`..�` ` .'+ -ME ., .. v"3'9'.. 4 I.. �.'�. U: -0.8`. . 11 Q:N.•�.o..I 38.53± ME . .. .. ...- . . . . . .•. . . . . . . . . ... . 39.13.' - i7 •' '•-._.:.'_ ... . . .�;_......`.'.'. ....... :.:::�T�412 39.20± N 10 .93. . %. . . . . II I 11 �0 •-•.••-`-•-•.•••-'� 38.90 I . ; 7 9.10 3 .22 Tm \�a • �' •' ` \ ' 9.1 1 PI . I • - m 3 .90 18 13' . .-. \ ` 39 07 T-CONSTRUCTION NOTES SITE PLAN 1. EXISTING BROWN BEAR CAR WASH WITH EMPLOYEE OFFICE. 2. NEW TRASH ENCLOSURE WITH CONCRETE PAD TO SURFACE FLOW. ENCLOSURE TO BE COVERED PER CORMC TITLE IV. 4-4-090. CONTRACTOR TO INSTALL CATCH BASIN AND ROUTE TO EXISTING SIDE SEWER. SEE ARCHITECTURAL PLANS FOR DETAILS. PAVEMENT I o ' SECTION PER DETAIL 7/C5.0. I 3. PARKING STALL MARKINGS SHALL BE 4" WIDE WHITE TRAFFIC PAINTED STRIPES (TYPICAL). I � LA 4. NEW ACCESSIBLE PAVEMENT MARKINGS PER DETAIL 1/C5.0. ' voted I 5. NEW ACCESSIBLE SYMBOL PER DETAIL 2/C5.0. i6. � NEW ACCESSIBLE AND "NO PARKING" SIGN PER DETAIL 3/C5.0. o 7. NEW ON -SITE BARRIER CURB PER DETAIL 4/C5.0. I I , � 8. NEW ON -SITE CURB AND GUTTER PER DETAIL 6/C5.0. o I i 9. NEW ASPHALT PAVEMENT PER DETAIL 9/C5.0. I ' N 10. NEW CONCRETE SLAB UNDER AUTO -SENTRY. PAVEMENT SECTION o I PER DETAIL 7/C5.0. P(UG) o - PiUG) P(Uc) I I 11. NEW AUTO SENTRY PAY STATIONS. CURBING TO BE LESS THAN 9". I SEE ARCHITECTURAL PLANS. V o M ° I EHI I \ / � Z ' I 12. NEW AUTO SENTRY CANOPY. SEE ARCHITECTURAL PLANS FOR DETAILS. o ' I 13. NEW LANDSCAPING. SEE LANDSCAPING PLANS FOR DETAILS. ItA , N CONTRACTOR TO GRADE LANDSCAPING AREAS TO PROMOTE POSITIVE d 9 m DRAINAGE. THE SOIL AMENDMENT BMP PER C.2.13 OF THE CORSWDM SHALL BE IMPLEMENTED IN ALL LANDSCAPED AREAS I I ON -SITE. i N 14. NEW LOCATION OF BEAR STATUES. CONTRACTOR TO CONFIRM FINAL ' I LOCATION WITH OWNER PRIOR TO CONSTRUCTION. ° I as �� ' 15. EXISTING LOT LIGHT. II I N d9 - J- ss ss - 16. EXISTING CURB TO REMAIN. / 17. NEW "EMPLOYEE PARKING ONLY" SIGN PER DETAIL 8/C5.0. o y/ ' EX SSMH 18. SAWCUT LINE. RIM=37.62' 12" DI N IE=30.40' EXISTING STORM PIPE TO BE 8" DI SW IE=30.53' CAPPED AND ABANDONED TO 8" DI E IE=30.12' FACILITATE PROPOSED STORM ' NETWORK IMPROVEMENTS. , CONTRACTOR TO PROVIDE OF RENTON STANDARD DETAIL 240.10. SEE DETAIL \ \ NECESSARY MATERIALS FOR 2 C5.1. h� �G� �^��� `�`, `-`��'. � `40. 1 4 + \`�� I I' CAPPING OF STORM LINE. / / \ ` 39.56_ ME �` �, a / RIM: 37.13 40. 6 26 LF 6" DI SD @ 4.03% I IE: 34.60 (8 IN W) y / J 5 81 LF 6" SDR-35 PIPE SS C� 2.00% MIN. �` � ` 1 I IE: 35.10 (8" OUT E) \ G 40.21 4042 3. PROPOSED CATCH BASIN PER CITY OF RENTON STANDARD PLAN 200.00. SEE DETAIL 1 /C5.1. 4. CONTRACTOR TO RAISE EXISTING CATCH BASIN TO FINISH GRADE. RIM:37.15 IE: 35.09 (6" W) EX. IE: 35.09 (8" E) GRADING NOTES: O ` �9 40.67± ME \ g J \` Y \ ��\ 1. ALL SPOT ELEVATIONS SHOWN ARE TO FINISH SURFACE (TOP OF ASPHALT OR TOP OF CONCRETE PAVEMENT, NOT TOP OF CURB/SIDEWALK) UNLESS OTHERWISE NOTED. (TA = TOP OF ASPHALT, TC = TOP OF CURB, FC = FLUSH CURB, GB = GRADE BREAK, ME = MATCH EXISTING ELEVATIONS, TPI = TOP OF ISLAND). 2. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL PROPOSED GRADES IN RELATIONSHIP TO SURVEYED BASIS OF ELEVATION. 3. FILL MATERIAL AND COMPACTION SHALL CONFORM TO CITY OF RENTON AND KING COUNTY REQUIREMENTS. 4. CONTRACTOR TO PROTECT AND MAINTAIN EROSION CONTROL MEASURES DURING GRADING OPERATIONS AND REMOVE AT END OF CONSTRUCTION. 5. CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH CITY OF RENTON AND KING COUNTY REQUIREMENTS. GEOTECHNICAL NOTES BASED ON ZIPPERGEO'S GEOLOGIC HAllARD AREA REPORT, DATED JULY 27, 2018, PRIMARY GEOTECHNICAL CONSIDERATIONS THAT MAY AFFECT ASPECTS OF DESIGN AND CONSTRUCTION INCLUDE REQUIRING VISUAL MONITORING BY THE CONTRACTOR OF TEMPORARY EXCAVATIONS AND THE IMPLEMENTATION OF TEMPORARY SHORING OR BUTTRESSING IF UNSTABLE TEMPORARY EXCAVATION SLOPES ARE OBSERVED. UTILITY CONFLICT NOTE: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 811 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL NOTIFY BARGHAUSEN CONSULTING ENGINEERS, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. \z 40.31 ± ME 15 / d. ^ / d d,. \ \ , I G I PROPOSED BENCH. CONTRACTOR TO \\� VERIFY SUITABLE LOCATION TO INSTALL BENCH OUTSIDE CARWASH. \\ `l UTILITY POTHOLING NOTE THE CIRCLED LOCATIONS ARE REQUIRED TO BE POTHOLED TO \ \ \ VERIFY VERTICAL AND HORIZONTAL LOCATION OF EXISTING UTILITY \\ \ AND/OR POTENTIAL CONFLICTS WITH EXISTING UTILITIES. I POTHOLING SHALL BE PERFORMED PRIOR TO INSTALLING ANY PROPOSED UTILITIES. CONTRACTOR SHALL NOTIFY BARGHAUSEN CONSULTING ENGINEERS, INC. OF ANY CONFLICTS. HORIZONTAL CONTROL NOTE: CONTRACTOR SHALL HAVE ALL PROPERTY LINES, CURB, SIDEWALK, STRUCTURES, CONCRETE PADS AND ANY OTHER ABOVE GROUND PERMANENT STRUCTURE DEPICTED ON THESE PLANS STAKED FOR CONSTRUCTION BY A LICENSED SURVEYOR. LICENSED SURVEYOR SHALL STAKE ALL ITEMS USING COORDINATE GEOMETRY (RECTIFIED TO SITE CONTROL) CONTAINED IN CAD DRAWING FILES PROVIDED BY BARGHAUSEN CONSULTING ENGINEERS, INC. IT IS THE CONTRACTOR'S RESPONSIBILITY TO RETRIEVE LATEST CAD FILES FROM BARGHAUSEN CONSULTING ENGINEERS INC., REFLECTING ANY ISSUED PLAN REVISIONS. BARGHAUSEN CONSULTING ENGINEERS SHALL IMMEDIATELY BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO THE START OF CONSTRUCTION. APPROXIMATE LOCATION OF SEWER CONNECTION TO CARWASH PER CITY OF RENTON SEWER CARD # 182305-9131 ROOF DRAIN NOTE: CONTRACTOR TO INSTALL ROOF DRAINS TO SURFACE FLOW ONTO PAVEMENT. SEE ARCHITECTURAL/MEP PLANS. ACB #2 18 PROPOSED POINT OF CONNECTION TO EXISTING 6" CONCRETE SEWER PIPE. CONTRACTOR TO INSTALL PVC TEE CUT IN TO EXISTING SIDE SEWER. q \ 2 REVISI❑NS PER CITY COMMENTS DATED 05/21/20 CMS 6/18/20 1 REVISIONS PER CITY COMMENTS LRH 3/19/20 NO. REVISION BY DATE IFIR Flip. LRH CRJ amm LRH CRJ * o ok AEM APPR CRJ � SO - SO Ln A=2'31'59" R=5655.00' I I ' L=250.01' ° N 0 I � ' 0 I / � i i 0 �I i i �� / o n 0 MATCH EXISTING ELEVATIONS AT EDGE OF NEW In PAVEMENT. CONTRACTOR TO INSTALL ASPHALT PAVEMENT TO MATCH EXISTING DRAINAGE PATTERNS. APPROXIMATE LOCATION OF EXISTING SIDE SEWER. CONTRACTOR TO TV EXISTING SEWER LINE TO VERIFY VERTICAL AND HORIZONTAL LOCATION PRIOR TO CONSTRUCTION. CONNECT PROPOSED SEWER LINE TO EXISTING SIDE SEWER. CONTRACTOR TO POTHOLE POINT OF CONNECTION TO CONFIRM VERTICAL AND HORIZONTAL LOCATION AS WELL AS PIPE SIZE, DEPTH, AND CONDITION. CONTRACTOR TO PROVIDE ALL NECESSARY FITTINGS/ADAPTORS TO MAKE CONNECTION. CONNECTION LOCATION SHALL VARY AS NEEDED TO CONNECT TO EXISTING SIDE SEWER AT A MINIMUM OF 2% SLOPE ON PROPOSED SEWER. ACTUAL CONNECTION LOCATION MAY ADJUST AS NECESSARY. CONTRACTOR SHALL NOTIFY BARGHAUSEN CONSULTING ENGINEERS, INC. OF ANY CONFLICTS. MATCH EXISTING ELEVATIONS AT EDGE OF NEW PAVEMENT. CONTRACTOR TO INSTALL ASPHALT PAVEMENT TO MATCH EXISTING DRAINAGE PATTERNS. Know what's below. Call before you dig. Dial 811 1In=10' am 40• Y F"L f�AR if tiw am +a• am occommalt Barghausen Consulting Engineers, Inc. 18215 72nd Avenue South Kent, WA 98032 425.251.6222 barghausen.com CITY OF RENTON Plonning/Building/Public Works Dept. CARWASH DISCHARGE NOTE: EXISTING CARWASH EFFLUENT CURRENTLY AND WILL REMAIN TO DISCHARGE TO SANITARY SEWER. ELECTRICAL DESIGN NOTES: CONTRACTOR TO CONFIRM ELECTRICAL CONDUIT REQUIREMENTS, ROUTING, PLACEMENT AND TRENCHING AND RESTORATION WITH OWNER PRIOR TO CONSTRUCTION. ELECTRICAL DESIGN PROVIDED PER OWNER. GEOLOGIC HAZARD NOTE: SITE IS ADJACENT TO GEOLOGIC HAZARD ZONES. HAYES PLACE SW ROW IS WITHIN LANDSLIDE HAZARD ZONE. PER THE CITY OF RENTON SWDM, INFILTRATION DEVICES MUST BE 50' FROM LANDSLIDE HAZARD ZONES. SEE GEOLOGIC HAZARD REPORT MENTIONED ON SHEET C1.0 FOR MORE DETAILS. G SWJENIs z - p 47671 S i ER, \�4 0 ro R-411401_ IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING WASTEWATER UTILITY Scott Warlick 7/15/2020 Ann Fowler 07/15/2020 CURRENT PLANNING , % SURFACE WATER UTILITY Mgelea Weihs 07/23/2019 W jfarah 07/15/2020 ' GRADING AND DRAINAGE SITE PLAN FOR BROWN BEAR CARWASH 77 RAINIER AVE S RENTON, WA 98057 1/10/2020 mm- omwo title 211at C4.0 7 I O qt I Q w MAXIMUM SLOPE IN — ANY DIRECTION SHALL NOT EXCEED 2.00% 36%36" BLUE — STENCILED SIGN (DETAIL 2/C5.0,' 0 N PARKING AREA " CURB g NO PARKING /Z /Z ALIGN EQUAL EQUAL 9'-0" 8'-0" SEE SITE PLAN ;DADA PARKING REQUIREMENTS NOT TO SCALE 3/8" JOINT PETROLEUM RESISTANT SEALANT PTI SEALANT 3/4" DEEP (MIN.) NEW PAVEMENT - ---------------------- a a a a . a . a a a 4 a a. a 4 i a d o ° A a ° < a a d 4. a ANSION JOINT (TYP.) NOT TO SCALE 0 Z J Q U 01 0 Ki 0 N 0 N 0 N O, Cm N 0 0 0 O N i JOINT FILLER CAST IN PLACE 00 CONSTRUCTION DETAILS U-) N FOR � RENTON BROWN BEAR AUTO SENTRY ADDITION 0 N NE QUARTER OF SECTION 18, TOWNSHIP 23 NORTH, RANGE 5 EAST W.M. U ACCESS AISLE 12" HIGH MIN. WHITE PAINTED LETTERING (MUST BE VISIBLE TO TRAFFIC CONTROL OFFICER) 4" WIDE PAINTED STRIPES (TYP.) WITH BLUE OUTLINE SEE GRADING SHEET C5.0 FOR ELEVATIONS AND SLOPES OF PROPOSED ACCESSIBLE PARKING STALL. CITY OF RENTON, KING COUNTY, WASHINGTON 3Ya" _ rn%,-LY5"Y ■■■■w ■lull, ll- 1 ■ �" ' �°I N LI I WHITE PAINT FIGURE PAINT —� CONTRASTING BLUE BACKGROUND 3'-0" WHITE BORDER PAVEMENT INTERNATIONAL SYMBOL OF ACCESSIBILITY NOTES: A. SYMBOL TO BE CENTERED ON WIDTH OF PARKING STALL. B. BOTTOM OF SYMBOL TO BE LOCATED FLUSH WITH ACCESS DRIVE,CENTERED ON PARKING SPACE. C. SYMBOL IS REQUIRED TO CONTRAST WITH BACKGROUND. INTERNATIONAL SYMBOL OF ACCESSIBILITY NOT TO SCALE 5-1/2" 1 /2" R 77-7 EN NLESS OTHERWISE LANDSCAPE OTED ON PLANS ADJACENT P) \` a a 6" I 12" ON -SITE CURB AND GUTTER NOT TO SCALE NT 18" PROVIDE ACCESSIBLE PARKING AND AISLE SIGNS AT LOCATIONS SHOWN ON PLANS. SET POST FOR SIGN INSIDE GUARD POST 42" HIGH GUARD POST PER DETAIL 4/C7.0 6" (MIN.) PORTLAND CEMENT CONCRETE PAVEMENT W/ #4 BARS Q 18" O.C. EA WAY @ MID —DEPTH. L-SUBGRADE COMPACTED TO 90% MAX DRY DENSITY, IF PRESENT ONSITE, AND CONSTRUCTED IN ACCORDANCE WITH UNSUITABLE MATERIAL STRUCTURAL PLANS AND CITY OF RENTON AND SHALL BE REPLACED KING COUNTY STANDARD SPECIFICATIONS. BY SUITABLE MATERIAL RECOMMENDED BY NOTE: THE GEOTECHNICAL (FOR REFERENCE ONLY) ENGINEER. ALL PORTLAND CEMENT CONCRETE PAVEMENT (PCC) SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER. ATYPICAL CONCRETE PAVING SECTION NOT TO SCALE 2 REVISI❑NS PER CITY COMMENTS DATED 05/21/20 1 REVISIONS PER CITY COMMENTS NO. REVISION LRH CMS 6/18/20 CRJ LRH LRH 3/19/20 CRJ aKoaeor AEM BY DATE APPR CRJ RESERVED PARKING (WHITE) (BLUE) 12% 18" SIGN STATE DISABLED PARKING PERMIT REDDiRED TEXT ACCORDING TO LOCAL JURISDICTIONAL VAN REQUIREMENTS ACCESSIBLE 12" NO PARKING ACCESSIBLE AISLE "NO PARKING SIGN" HEIGHTS ACCORDING TO LOCAL REQUIREMENTS IF N I SIGN IS LOCATED IN PEDESTRIAN TRAFFIC, LOCATE I BOTTOM OF SIGN AT 80" ABOVE WALKING SURFACE, AND 60" IF OUTSIDE OF WALKING SURFACE WALKING SURFACE FLEXIBLE POST ON SHORT POLE INSTALLATIONS ZUMAR INDUSTRIES (800) 426-7927 OR 2"0 STEEL POLE ON INSTALLATIONS ABOVE 5'-0" ACCESSIBLE PARKING AND AISLE SIGNS ;5.0,jNOT TO SCALE 12" EMPLOYEE PARKING ONLY NOTE: 1. USE POST DETAIL FROM DETAIL 3 THIS SHEET. 2. CONTRACTOR TO FURNISH SIGN AND INSTALL MATERIALS AS DEPICTED OR SIMILAR. EMPLOYEE PARKING SIGN (TYP) NOT TO SCALE Know what's b@Iow. Call before you dig. Dial 811 NA am +o• Y F"L f�AR •Wum+a• Barghausen Consulting Engineers, Inc. 18215 72nd Avenue South Kent, WA 98032 425.251.6222 barghausen.com CITY OF RENTON Planning/Building/Public Works Dept. 5 1/2" 7 3/4" ONSITE BARRIER CURB NOT TO SCALE 3" (MIN.) COMPACTED DEPTH J ASPHALTIC CONCRETE 6" CRUSHED ROCK BASE OR 4" ATB SUBGRADE COMPACTED TO 90% MAX DRY DENSITY, AND CONSTRUCTED IN ACCORDANCE WITH CITY OF RENTON AND KING COUNTY STANDARD SPECIFICATIONS. �•� �YiLI» IF PRESENT ONSITE, UNSUITABLE MATERIAL SHALL BE REPLACED BY SUITABLE MATERIAL RECOMMENDED BY THE GEOTECHNICAL ENGINEER. NOTE: 1. DETAIL IS FOR REFERENCE ONLY. GENERAL CONTRACTOR SHALL CONSULT GEOTECHNICAL ENGINEER FOR PAVEMENT, AGGREGATE, OVER -EXCAVATION AND SUBGRADE REQUIREMENTS. 2. HMA IS TO BE IN CONFORMANCE TO WSDOT SECTION 9-03.8(2). 3. AGGREGATE IS TO BE IN CONFORMANCE TO WSDOT SECTION 9-03.8(6). TYPICAL ON -SITE AC SECTION NOT TO SCALE f\S, ISN WJEN H� ei�2: - p 47671 �`FS FC l S i S/0NA L ro R - 411401 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING ` Scott Warlick 7/15/2020 CURRENT PLANNING Angelea Weihs 07/23/2019 1 /10/2020 CONSTRUCTION DETAILS FOR FXL BROWN BEAR CARWASH 77 RAINIER AVE S RENTON, WA 98057 1I`t C5.d' 7 ., 0 z J Q Cn U D Lv 0 Ki 0 N CD 00 00 0 I 0 N I, Cm N CD 0 0 N i SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD. PLAN NOTES.. 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETINd'SHALL BE HELD AMONG THE CITY OF RENTOAI,HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR. 2. THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, STATE, AND FEDERAL PERMITS PRIOR TO CONSTRUCTION.. 3. ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM), RENTON MUNICIPAL CODE (RMC), AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY. 4. APPROVAL OF THE ROAD, GRADING, PARKING, BUILDING, AND DRAINAGE PLAN DOES NOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION (E.G. WATER, SEWER, GAS, ELECTRICAL. ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES, VAULTS, AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY. 5, A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 6. THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE APPLICANT'S CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN, AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN, THE APPLICANT SHALL RECORD ON THE AS -BUILT DRAWINGS ALL UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD IF A CONFLICT EXISTS. 7. VERTICAL DATUM SHALL BE NAVD 88 AND HORIZONTAL DATUM SHALL BE NAD 83 (WA STATE PLANE, NORTH), UNLESS OTHERWISE APPROVED BY THE CITY. REFERENCE BENCHMARK, DATUM, AND ELEVATIONS SHALL BE NOTED ON THE PLANS. 8. ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 95 % MAXIMUM DRY DENSITY PER SECTION 2-03.3(14)D - COMPACTION AND MOISTURE CONTROL TESTS OF THE WSDOT STANDARD SPECIFICATIONS. IN PERMEABLE PAVEMENT AND OTHER INFILTRATION AREAS, ALL TRENCH BACKFILL SHALL BE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN 92 % OF MAXIMUM DRY DENSITY. 9. OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS. 10, ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY THE CITY, THE EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED. 11. ALL FLOW CONTROL FACILITIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO, OR IN CONJUNCTION WITH, ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE CITY. 12. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220.00, 220.10, AND', 220.20. 13. STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT 1, 2, OR 5 INSIDE AND OUTSIDE, 14. ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH DUCTILE IRON, BOLT -LOCKING LIDS PER THE CITY STANDARD PLAN 204.10, 204.20, 204.30, AND 204.50. STRUCTURES SHALL HAVE: • RECTANGULAR OR ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND OUTSIDE OF THE ROADWAY. • ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY, BUT OUTSIDE OF THE CURB/GUTTER LINE. • ROUND, SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT-OF-WAY OR IN AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS OUTSIDE PUBLIC RIGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO. 15. BUILDINGS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT WIDTHS AND BUILDING SETBACKS LINES OF THE RENTON SWDM. 16, LIDS OF MANHOLES/CATCH BASINS WITHIN PUBLIC RIGHT-OF-WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING. ALL MANHOLE/CATCH BASIN RIMS SHALL BE ADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN. 17. ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 267.00 PUBLIC WORKS SURFACE WATER STANDARD PLAN PPRD: 9/Uz7.00 I ,� U1� DEPARTMENT NOTES (1 OF 2) GAZ DATE SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD. PLAN NOTES.. 18. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE (1) FOOT AND SHALL MEET THE FOLLOWING SPECIFICATIONS: • 4 - 8 INCH ROCK / 40 - 70 % PASSING; • 2-4INCH ROCK /30-40%PASSING; AND • LESS THAN 2 INCH ROCK / 10 - 20 % PASSING. 19. FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE, UNLESS APPROVED BY THE CITY. FOOTING DRAINS SHALL NOT BE CONNECTED TO ON -SITE BMPS. ,20. THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED. A CLEANOUT TOPPED WITH A BOLT -LOCKING LID MARKED "STORM" SHALL BE LOCATED AT THE PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227.00. 12t ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED TO THE CITY PRIOR TO CONSTRUCTION. 22. ALL NEWLY -INSTALLED AND NEWLY -REHABILITATED (PUBLIC AND PRIVATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV ACCORDING TO THE CITY STANDARD PLAN 266.00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS, GUTTERS AND/OR PAVEMENT. 23, ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7-04.3(1) OF THE WSDOT STANDARD SPECIFICATIONS AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS TESTED. 24. FOR ALL DISTURBED' PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN 264.00. 25. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION ANDTOR LIABILITY CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE STORM SYSTEM PROVIDED DURING CONSTRUCTION. 26 ADEQUATE SAFEGUARDS, SAFETY _DEVICES;'PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER ACTIONS'NEEDED TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CITY. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY. 27. PROJECTS LOCATED WITHIN THE CITYS AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPECIAL REQUIREMENT #6 OF THE RENTON SWDM AND AQUIFER PROTECTION REGULATIONS (RMC 4-3-050). 28. PLACEMENT OF SURFACE APPURTENANCES (CATCH BASIN/MANHOLE LIDS, CLEANOUTS, INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS OF STREET TRAVEL LANES, BIKE LANES, SIDEWALKS, AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID LID PER ADA REQUIREMENTS. 29. CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE _APPLICANT. 30. MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1.A2 OF THE RENTON SWDM. 31. CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER THE PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES. COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO CONSTRUCTION APPROVAL OF THE PAVEMENT. COMPLIANCE MAY BE CHECKED USING A SIMPLE BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO THE PAVEMENT SURFACE ALL AT ONCE. IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE, THEN THE PAVEMENT IS CONSIDERED TO MEET THE MINIMUM RATE OF ABSORPTION. AT LEAST ONE TEST SHALL BE CONDUCTED PER 1,000 SQUARE FEET OF PERMEABLE PAVEMENT. IF THIS TEST IS NOT CONCLUSIVE, THEN ANOTHER TEST PER ASTM C1701 .SHALL BE CONDUCTED. FOR LARGE AREAS (E.G., PARKING AREAS), TESTING OBSERVATION MAY BE. ACCOMPLISHED WHILE WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TEST. PERMEABLE PAVERS SHALL BE TESTED USING ASTM C1781. 1JNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 267.10 -�_ IL PUBLIC WORKS SURFACE WATER STANDARD PLAN PPR DEPARTMENT NOTES (2 OF 2) GAZ 9/28/2018 1 W tl­ �­­ ­, DATE :45 :45 00 CONSTRUCTION NOTES to N FOR � RENTON BROWN BEAR AUTO SENTRY ADDITION 0 N NE QUARTER OF SECTION 18, TOWNSHIP 23 NORTH, RANGE 5 EAST W.M. U .4". 6", 12", OR 24" ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 RECTANGULAR ADJUSTMENT SECTION CITY OF RENTON, KING COUNTY, WASHINGTON PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR PLAIN 12" CONCRETE ALL METAL PIPE 15" CPSSP", 12" STD. SPEC. 9-05.20 SOLID WALL PVC, STD. SPEC.9-05.12(1) 15 PROFILE WALL PVC, STD. SPEC. 9-05.12(2) 15" CORRUGATED POLYETHYLENE STORM SEWER PIPE 6 sFFNz, NOTES: 9� OrF 1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS IN (PLACED ACCORDANCE WITH STANDARD SPECIFICATION HAVING AI NIMUM AREA 0.112 SQUARER CIHES PER FOOT SHALLMESH BE USED W THE io THE MINIMUM REQUIRED REBAR SHOWN IN THE / I ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN I L - �I THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH #3 BAR EACH CORNER / ' 1. HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER ! (FOOT MAY BE USED. 1;1 ITkE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" / MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE I y OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, / FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH #3 BAR EACH SIDE STANDARD SPECIFICATION 9-04.3. 3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO e THE LOWEST PIPE INVERT SHALL BE 5 FEET. #3 BAR EACH WAY 4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN, PRECAST BASE SECTION 5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1 H:24V OR STEEPER. #3 BAR HOOP 6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE / PRECAST BASE SECTION. / 7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR #3 BAR EACH NON -SHRINK APPLICATIONS IN ACCORDANCE WITH / / CORNER 18" MIN. STANDARD SPECIFICATION 9-20.3(2). I 8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. [0) 'MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. O:I FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. i. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND SEE NOTE 1 REMAIN VISIBLE UPON COMPLETION. ALTERNATIVE PRECAST BASE SECTION UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) � STD. PLAN - 200aIQ PUBLIC WORKS APPR ED: CATCH BASIN TYPE 1 GAZ 9/28/2018 1 DEPARTMENT Public Wo. Adm ,,t,.m DATE CATCH BASIN DETAIL NOT TO SCALE 2 IREVISI❑NS PER CITY COMMENTS DATED 05/21/20 1 REVISIONS PER CITY COMMENTS NO. REVISION 0 Know what's below. p Call before you dig. 1 Dial 811 i 90"CAM > NA IFIR F°e LRH CMS 6/18/20 CRJ LRH mquI= •Wummm I= ACCIIIIIIIIIIIIIIIIIIIIIIII111, LRH 3/19/20 CRJ AEM BY DATE APPR I CRJ 20' MAX. (RECOMMENDED) ACCESS COVER OVERINLET - INLET PIPE I (8" MIN.) SEE NOTE & HIGH FLOW (TYP.) - BYPASS SEE NOTE 5 (TYP.) 12" MIN. VENTILATION PIPES AT CORNERS (TYP.) � COALESCING PLATE RACK III II III r , II II II L JII II II I I r III II III FOREBAY II nl L JII III F 2' MIN. COVER rACCESS COVER OVER OUTLET -LADDER (TYP.) 5' MAX. SHUT OFF VALVE W / RISER II AFTERBAY AND VALVE BOX II OUTLET PIPE IS" MIN.) SEE NOTE 5 (TYP.) ACCESS'16601R1ALLOWINGREMOVAL OF PLATE PACK OR PROVIDE FULL LENGTH REMOVABLE COVERS ACROSS ENTIRE CELL PLAN VARIES (CAN BE CONSTRUCTED ON GRADE WITHOUT RISERS) TEE T 6" MIN. 1 WATER QUALITY 12" MIN. WATER SURFACE 20' MAX. I 12" MIN. SEE NOTE 5 (TYP.) �,. 7' SUBMERGED MIN. COALESCING "�" OIL RETAINING INLET PIPE PLATE RACK BAFFLE (50% D MIN.) 18" GRAVITY DRAIN MIN. 12" MIN. 6" MIN. U3 MIN. I 8' MIN. (U2 RECOMMENDED) (L/4 RECOMMENDED) INLET WEIR -SOLIDS RETAINING BAFFLE OR WINDOW WALL L NOTES: 1. THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2. GRAVITY DRAIN SHALL BE AT LEAST 8 INCH MINIMUM DIAMETER AND SHALL BE CONTROLLED BY A VALVE. USE OF A SHEAR GATE IS ALLOWED ONLY AT THE INLET OF A PIPE LOCATED WITHIN AN APPROVED STRUCTURE. 3. ACCESS TO EACH COMPARTMENT IS REQUIRED, ON EACH END, AND EVERY 50 FEET MINIMUM. 4. VAULTS PROVIDING MANHOLE ACCESS AT 12 FOOT SPACING NEED NOT PROVIDE CORNER VENTILATION PIPES. VENTILATION PIPES SHALL BE CAPPED OR OTHERWISE COVERED, BUT DESIGNED SO THAT MAINTENANCE PERSONNEL CAN REMOVE FOR VENTILATION. 5. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 6. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) STD. PLAN - 240.10 .�.�ft PUBLIC WORKS COALESCING PLATE OIL / WATER [PPRMED: ' DEPARTMENT SEPARATOR GAZ 9/28/2018 1 vkavPublic Wad Ad-i-t., DATE OIL/WATER SEPARATOR DETAIL NOT TO SCALE Barghausen Consulting Engineers, Inc. 18215 72nd Avenue South Kent, WA 98032 425.251.6222 barghausen.com -AM.M4°N 1 CITY OF RENTON Planning/Building/Public Works Dept. :4 G �\s BEN �y/ P o z - p 47671 �`FS FC I S i s/0NA L R - 411401 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Scott Warlick 7/15/2020 CURRENT PLANNING Angelea Weihs 07/23/2019 1 /10/2020 CONSTRUCTION NOTES nhoomw FOR BROWN BEAR CARWASH 77 RAINIER AVE S RENTON, WA 98057c5.�'� 7 EXIE VEG TO F HELI BLUI HAK GOL MAG LITTI PENT LITTI Landscape Plan \� I I \. \/Al"t'`IAlll IRA /l\/ATI IRA / C\/CE3L`E3CCAI U1 1f V1 CQCoov CITY REVIEW - NOT FOR CONSTRUCTION SCALE: 1 "=20'-0" 0 10, 20' 40' zz B D C-, z _z < 411111111w CL:" 00 410111111010. CL Lu N u.] mail v 4330 N Lexington St u Tacoma, WA 98407 V) I— W = location Q u 455B St Helens Ave Q Tacoma, WA 98402 Q t.253.272.4848 C f.253.276.0132 z www.bradtree.com CC <" info@bradtree.com adOd� a N �Q STATE OF WASHINGTON REGISTERED LANDSCAPE_ARCHITECT thl a Brad ey o. z 0 z z Q0- Q J X z00 Lu — °1 Q w = W LrI � o � z w w u Q w `/' Lu Ln V Ln ; Q C) Q� Q 0� Q � z Z w U Q Q m z J � 0 ry m REVISION No. Date By 1 07 Jan 2019 YSL Rev. per Sit Plan Change Scale 1" = 20'-0" Designer Sheet No. YSL Project Manager MFW P nciZI KBR Date o{ 2 Sheets 16 April 2018 Phase CD a PLANT SCHEDULE: SYMBOL QTY. BOTANICAL NAME / COMMON NAME TREES - DECIDUOUS SIZE SPACING, CONDITION & REMARKS 1 MAGNOLIA X GRAN DIFLORA'LITTLE GEM' / LITTLE GEM SOUTHERN MAGNOLIA 2" CAL. B&B, MULTI -TRUNK (3 CANES), EVENLY BRANCHED 2 PRUNUS CERASIFERA'CIPRIOZAM' / CRIMSON POINTE PLUM 2" CAL. B&B, BRANCHED @ 5' HT. (STREET TREE QUALITY) TREES -EVERGREEN a— 11 CALOCEDRUS DECURRENS / INCENSE CEDAR 4'-5' HT. B&B, NURSERY GROWN SHRUBS 16 ARBUTUS UNEDO'COMPACTA' / COMPACT STRAWBERRY BUSH 15 BERBERIS THUNBERGII 'ROSE GLOW'/ ROSE GLOW JAPANESE BARBERRY 10 CHOISYA TERNATA / MEXICAN ORANGE 9 HEBE 'PATTY'S PURPLE' / PATTY'S PURPLE HEBE S 11 JUNIPERUS SCOPULORUM 'SKYROCKET' / UPRIGHT JUNIPER 5 MYRICA CALIFORNICA / PACIFIC WAX MYRTLE O 15 RIBES SANGUINEUM / RED FLOWERING CURRANT 25 SPIRAEA JAPONICA'GOLDMOUND' / GOLDMOUND SPIREA 14 VACCINIUM OVATUM / EVERGREEN HUCKLEBERRY FERNS, GRASSES & PERENNIALS 31 CHALAMAGROSTIS X ACTUTIFLORA'KARL FOERSTER' / FEATHER REED GRASS 23 HAKONECHLOA MACRA'AUREOLA' / GOLDEN JAPANESE FOREST GRASS O 95 HELICTOTRICHON SEMPERVIRENS 'SAPHIRSPRUDEL' / BLUE OAT GRASS 19 NEPETA X FAASSENII 'WALKER'S LOW' / WALKER'S LOW CAT MINT 39 PENNISETUM ALOPECUROIDES'LITTLE BUNNY' / LITTLE BUNNY FOUNTAIN GRASS 36 SEDUM 'AUTUMN JOY' / AUTUMN JOY SEDUM GROUNDCOVER 607 FRAGARIA'PINK PANDA' / PINK PANDA SAND STRAWBERRY EXISTING VEGETATION TO REMAIN 1-3 MAN PLACEMENT ROCKS tQ�0 PLANTING REQUIREMENTS: GENERAL NOTES: A. Plant material list submittal: within 30 calendar days after receipt of the notice to proceed, landscape contractor shall submit a complete list of materials proposed to be furnished and installed demonstrating conformance with the requirements specified. Include the name, addresses and telephone numbers of all plant material suppliers and growers. 1.A. Documentation shall also include suppliers name, contact person, address, telephone number, botanical and common name, plant size and size of container or ball. 1.B. Contractor shall provide a signed statement from the plant suppliers who have furnished the plant materials identifying the plant materials being supplied by botanical and common names, plant size and stating that all of the plants supplied by them are in healthy growing conditions meeting the asns. 1.C. Submit a project installation schedule, coordinated with the proposed soil amending and planting schedule to the landscape architect or owner for approval at least 30 calendar days prior to start of work under this section. B. Substitutions of plant materials will not be permitted unless authorized in writing by the landscape architect or owner. If proof is submitted that any plant specified is not obtainable, a proposal will be considered for use of the nearest equivalent size and or variety. Such proof shall be substantiated and submitted in writing to the landscape architect or owner at least 30 days prior to start of work under this section. These provisions shall not relieve contractor of the responsibility of obtaining specified materials in advance if special growing conditions or other arrangements must be made in order to supply specified materials. C. Plants shall be subject to inspection and approval by landscape architect or owner for conformance to specifications upon delivery to the project site. Such approval shall not impair the subsequent right of inspection and rejection during progress of the work. Contractor shall give landscape architect 48 hours advance notice when plants will be delivered to the site for inspection. Inspection of plant materials shall take place within 24 hours of delivery to the site. D. Coordinate work with other trades as required. E. Locate all underground utilities prior to commencing work to avoid damage to buried pipes and cables. F. Provide protection for all property, persons, work in progress, structures, utilities walls curbs and paved surfaces from potential damage arising p p 9 g from this work. The contractor shall a for an such damage at no pay Y 9 additional cost to the owner. Unfinished and completed work shall be protected from erosion or trespassing, and proper safeguards shall be erected to protect the public from injury or danger. PLANTING NOTES: 1. Verify bedlines and plant layout with landscape architect prior to commencing work. 2. Verify that site conditions are acceptable prior to beginning work. Do not install any site elements or plant material until unsatisfactory conditions are corrected. When conditions detrimental to plant growth/constructed elements are encountered, immediately notify the owner. 3. Substitutions or changes in materials and placement shall be made only after written change orders are accepted by the owner. 4. Install protective fencing for on site existing trees and vegetation to remain, and plant material located on adjacent property prior to commencing work. The critical root protection area of all trees to remain has been established as a 1' radius of protection area for every 1" of diameter measured at 4.5' above grade, or the tree drip line, whichever is greater. Locate tree protection fencing as indicated on plan. Fencing is to be installed with stakes driven into the ground, not mounted on cinder blocks. Signage shall be affixed to the fencing that reads: 'No Entry, Tree Root Protection Area'. See existing tree and vegetation protection detail for additional information. 5 GAL. CONTAINER FULL FOLIAGE, 42" O.C. 2 GAL. CONTAINER FULL FOLIAGE, 36" O.C. 5 GAL. CONTAINER FULL FOLIAGE, 36" O.C. 2 GAL. CONTAINER FULL FOLIAGE, 36" O.C. 4'-5' HT. B&B, NURSERY GROWN 5 GAL. CONTAINER FULL FOLIAGE, 48" O.C. 2 GAL. CONTAINER FULL FOLIAGE, 36" O.C. 2 GAL. CONTAINER FULL FOLIAGE, 36" O.C. 2 GAL. CONTAINER FULL FOLIAGE, 42" O.C. 1 GAL. CONTAINER 24" O.C. 1 GAL. CONTAINER 18" O.C. 1 GAL. CONTAINER 18" O.C. 1 GAL. CONTAINER 18" O.C. 1 GAL. CONTAINER 12" O.C. 1 GAL. CONTAINER 24" O.C. 4" POTS 18" O.C. 5. All areas subject to clearing and grading that have not been covered by impervious surface, incorporated into a drainage facility or engineered as structural fill or slope shall, at project completion, demonstrate the following: 1) General Soil Requirements: The topsoil layer shall have a minimum depth of eight inches except where tree roots limit the depth of incorporation of amendments needed to meet the criteria. Subsoils below the topsoil layer should be scarified at least 4 inches with some incorporation of the upper material to avoid stratified layers, where feasible. The topsoil layer shall have an organic matter content of 5% dry weight for turf areas, and 10% dry weight for planting beds (typically around 20-25% compost for turf areas and 35-40% compost for planting areas). The soil portion must be 75-80% sandy loam for turf areas, and 60-65% sandy loam for planting areas. Soil pH should be 5.5-6.5 for turf areas, 5.5-7.0 for planting areas and 4.5-5.5 for areas planted with acid -tolerant or native plantings. 2) Requirements for Amending Existing Soil in Place: Turf Areas - Place and rototill 1.75 inches of composted material into 7.75 inches of existing soil for a total depth of 9.5 inches, and a settled depth of 8 inches. Subsoils below this layer should be scarified at least 4 inches, for a finished minimum depth of 12 inches of uncompated soil. Planting Beds - Place and rototil 3 inches of composted material into 6.5 inches of existing soil for a total depth of 9.5 inches, and a settled depth of 8 iches. Subsoils below this layer should be scarified at least 4 inches, for a finished minimum depth of 12 inches of uncompated soil. Do not scarify within drip lines of existing trees to be retained. 3) Requirements for Applying Imported Topsoil: Turf Areas and Planting Areas - Scarify or till subgrade in two directions to 6 inches depth. Entire surface should be disturbed by scarification. Do not scarify within drip lines of existing trees to be retained. Place 4 inches of imported topsoil mix on surface and till into 2 inches of soil. Place second lift of 4 inches topsoil mix on surface. 4) Requirements for Reapplying Stockpiled Topsoil: Turf Areas - Reapply stockpiled soil and rototill in 1.75 inches of composted material for a combined minimum depth of 8 inches of soil and compost. Planting Beds - Reapply stockpiled soil and rototil in 3 inches of composted material for a combined mimimum depth of 8 inches of soil and compost. 5) Within Stormwater Systems - On -site soil mixing or placement shall not be performed if soil is saturated or frozen. Total amended soil depth p p shall be a minimum of 18 inches. Mix all soil amendments uniformally throughout the rain garden soil section. Amended soil shall be placed in horizontal layers in no greater than 12" lifts. Allow soils to compact and settle naturally. Areas can be watered after each lift is placed to speed settling, but should not be wetted to saturation. Until the upstream catchment area is thoroughly stabilized, flow diversion and erosion control measures must be installed to protect the bioretention area from sedimentation. 6) Rake beds to smooth, clean and remove all rocks, roots and debris over 1 inch in diameter. Water or roll turf areas to compact soil to 85 percent of maximum. Finish grade shall be at least 3 inches below adjacent hard surfaces for planting areas to allow for application of mulch. Finished grade for turf areas shall be at least 2 inches below adjacent hard surfaces. All planting areas must be mulched with 2 inches of organic material. 6. Plants shall be pit planted with a 50/50 prepared mix of native soil and topsoil mix. See planting details for depth and staking requirements. 7. Fertilize all installed plants during backfill operations with organic fertilizer as recommended by manufacturer. 8. Mulch all planted areas with a minimum 2 inch (2") depth of medium fine bark mulch. Finish grade of mulch shall be one inch (1") below top of adjacent hard surface. 9. All plant material to be nursery grown stock and arrive on -site in a healthy, vigorous, well branched, disease and insect free condition. 10. Plant trees, shrubs and groundcover as shown in the planting details. Roughly scarify sides of the planting pits. Install plant material at finish grade and feather bark mulch away from base of plant. Water plant pits thoroughly midway through backfilling and add fertilizer tablets. Balled and burlapped material that cannot be installed immediately shall be heeled in, mulched and watered regularly to keep root balls moist. 11. Provide landscape maintenance immediately after planting and continue until final acceptance. Work shall include watering, spraying, fertilizing, pruning, resetting of plants, restoring eroded areas, adjustments to staking and removal of weeds/debris as required for healthy plant growth. 12. Inspection and acceptance: the owner will make an inspection for substantial completion of the work upon request by the contractor. 13. Replacement of plantings: remove any plant from site that is either dead, or in unsatisfactory condition as determined by the owner or landscape architect. Replace with a new planting of equal size and species as soon as conditions permit within the normal planting season. All replacement plantings are then to be under re -instated guarantee period as specified. Identify those replacements and take whatever measures necessary to prevent similar demise of additional plant material. 14. Provide root barrier in a surround or linear pattern for tree plantings when trunk is located within five(5) linear feet of any paved surface. Deeproot universal barrier #ub18-2 (or approved equal). Install per manufacturer's recommendations. Warranty: The warranty shall include replacing and planting the same size and pp p species of plant material as shown on the landscape Ian and that has p been designated, by the landscape architect, to be replaced. Except for loss due to excessively severe climatological conditions (20 year weather charts), installed plant materials are required to be guaranteed until the end of one growing season against defects and unsatisfactory growth, except for cases of neglect or abuse by the owners or others. All plants replaced shall be re -instated under these plant guaranty conditions. PLANTING DETAILS: Provide min. 4'-0" high protective mesh fence and support with wood posts at dripline of existing trees and vegetation to be protected during construction i A IN \\ Plan ° ° In areas where'construction activity may cross into dripline, place 6" of medium size wood chips and cover with a metal plate \I I Existing Tree & Vegetation - Protection Detail (Not To Scale) Fertilizer tablets quantity per manufacturer's recommended application rates _ Provide 6" clearance b€twee root ball and edge of planting pit. Cut and remove bui 1/3 of ball or complE *remove all treated or container* nonbio-degradable materials 2" layer mulch feather away from trunk .fin I.,.. w I^k +.,..+k. Slope conditions Shrub Planting Detail_ (Not To Scale) C III I i<�iy�iy� 50 native & 50 vI 11 v� topsoil mix Fertilizer tablets quantity per J manufacturer's recommended application rates 1 gal. or 4" potted plant material Mound soil to form basin me 0 C 3" above grade. �, - Provide 3" clearance ,y ' -3„ between root ball and 00 0 Equidistant edge of planting pit. spacing Use knife or sharp blade to cut through bottom half of root ball. Butterfly rootball to bring 0 0 0 the root system closer to the surface. Groundcover Plantin (Not To Scale) Detail CITY REVIEW NOT FOR CONSTRUCTION 2" layer mulch, feather away from trunk Mound soil to form basin 6" above grade III III I =1 I I III III III III III �iv�/� � -III III III III \�� III IIIIIIIIIIIII III III- �11_ 11 111 11 '- 50 native & 50 \VA�� III III Fertilizer tablets quantity per topsoil mix 6" III 1- manufacturer's recommended IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII II Illly. application rates Cut and remove burlap from top 1/2 of 12" greater than ball. Remove all treated or non bio-degradable material. Root ball width Conifer Tree Plantin (Not To Scale) Finish Grade Sidewalk 1" 2X Min. Dia. Rootball Detail 1 /2" Dia. Black Rubber Hose (Typ) 12 Ga. Wire, Twist to Tighten 2" Dia. Tree Stakes (Typ) Tree Wrap as Specified to First Branching. Remove Burlap and Twine (and Wire Baskets) Off Top 1 /3 of Rootball 2" Mulch Layer Feathered Away from Trunk j 3" Water Basin Curb & Asphalt I F­ Root barrier (see note #2) _ I Break Sides and Bottoms of Planting Pit to Allow for Root Penetration Planting Mix as Specified Fertilizer Tablets as Specified Compacted Soil Base Fertilizer Tablets as Specified NOTES: 1. Plant Tree 1 Inch Higher Than Depth Grown In Nursery. Tree Pit Shall Not Be Less Than (2) Times Diameter of Rootball. 2. Rootbarrier Shall be 12 In. Deep and 8 L.F. on Each Side of Rootball Adjacent to Curbs and Paved Surfaces. 3. There Shall be a Minimum Rootball Diameter of 10 In. Per Trunk Caliper Inch as Measured 6 In. Above Rootball. Tree w/ Root Barrier Planting Detail_ z Z BDG Z _ Z 0::5 0 a1111111111W 0 0 V) Ise ■ ,� V + ■ N w ne mail V 1­— 4330 N Lexington St Tacoma, WA 98407 W = location Q U 455B St Helens Ave Q Tacoma, WA 98402 t.253.272.4848 0 f.253.276.0132 Z www.bradtree.com CD � info@bradtree.com a0d� a� �Q STATE OF WASHINGTON REGISTERED LANDSCAPE- RCHITECT Lill a Brad ey o. Z 0 Z Z J rQ' X z 00 LI..I _ LLI 01 W Ln o � � z LL I Lu U Q W � ; U U-) a 0 W Q z Zw�< Q m Z O 0� m REVISION No. Date 13y 1 07 Jan 2019 YSL Rev. per Site Plan Changes Scale 1" = 20'-0" Designer Sheet No. YSL Project Manager MFW L-1 Principal KBR Date of 2 Sheets 16 April 2018 Phase CD Project No. 18oi� \ \ \ PROPERTY LINE \ \ Irrigation Plan CITY REVIEW - NOT FOR CONSTRUCTION SCALE: 1 "=20'-0" 0 10' 20' 40' 'V Uz ZZ z �w c0C t) v + Ie Z= Vu t/) 1-- ua = ?- w z CD � BAG mail 4330 N Lexington St Tacoma, WA 98407 location 455B St Helens Ave Tacoma, WA 98402 t.253.272.4848 f.253.276.0132 www.bradtree.com info@bradtree.com adOd� STATE OF WASHINGTON REGISTERED LANDSCAPE, thl a Brad ey o. z 0 V) z z Q Q JLu X V z 00 cy, = w zQ�0 (n `�' z O > � w z w — z u; Q w w U-) Q QV Q Q w z — ry LIJ m Q V Q ry z 0 ry m REVISION No. Date By 1 07 Jan 20% YSL Rev. per Sit Plan Changes Scale 1" = 20'-01 1 Designer Sheet No. YSL Project Manager I _ MFW Principal KBR Date of 2 Sheets 16 April 2018 Phase CD Project No. 18oi� DRIP IRRIGATION EQUIPMENT SCHEDULE: DRIP DETAILS: Uz z_ B D C-, HUNTER IRRIGATION EQUIPMENT SHOWN IN SCHEDULE. TORO, RAINBIRD, WEATHERMATIC OR EQUIVALENT IRRIGATION EQUIPMENT MAYBE SUBSTITUTED, "" z WITH LANDSCAPE ARCHITECT'S WRITTEN APPROVAL ONLY. .•<LU '` CL SYMBOL DESCRIPTION REMOTE CONTROL VALVE WITH DIS'b O E... 0 FILTER AND PRV ■ O BRASS GATE VALVE - RuB Ball Valve - Model S951F43 (Round Handle) - SIZE TO FIT MAINLINE [ '—J BFP I BACKFLOW ASSEMBLY - FEBCO LF850 (SIZE TO MATCH METER) Z mail l— 4330 N Lexington St WATER METER (SEE CIVIL PLAN - COORDINATE POC WITH CONSTRUCTION MANAGER) V UW Tacoma, WA 98407 RAIN SENSOR -HUNTER RAIN-CLIK-WIRELESS RAIN SENSOR (WRC-INT) OR EQUAL, SEE GENERAL NOTE C PVC OR POLY SUPPLY HEADER NOTES: � ~' I LU = location 1. SEE PLANS & LEGEND Q Q ne U 455B St Helens Ave CONTROLLER - HUNTER PCC 6 ZONE - PCC-600i (X-CORE, PRO-C, PCC, I -CORE, ACC) I I FINISH GRADE Q Tacoma, WA 98402 CLASS 200 PVC LATERAL LINE PIPING, SIZE PER PLAN I START CONNECTION MALE ADAPTER FOR ALL DIMENSIONSLU COMPACTED AND Techline LATERAL Q t.253.272.4848 2" SCHEDULE 40 PVC MAIN LINE I I SUBGRADE SPACING U f.253.276.0132 CLASS 200 PVC SLEEVE 2X PIPE DIAMETER, 4" MIN. Techline TUBING 2. RATIO OF Techline LAT- z www.bradtree.com Not Shown #14 AWG TYPE OF CONTROL WIRE, RED = SIGNAL, WHITE = COMMON, ORANGE= SPARE I I DRIPLINE (TYP.) I PVC HEADER ERALS TO START CON- info@bradtree.com I P.S.I. GPH Techline TEE (TYP.) NECTIONS IS SHOWN AT HUNTER DRIP LINE - PLD-04-12 (12" EMITTER SPACING x 12" ROW SPACING) 15-50 .40 I r� AREA PERIMETER 2:1, BUT MAY VARY PER ado�%/� Techline START HYDRAULIC DEMAND ON HUNTER DRIP LINE -PLD-04-18 (18" EMITTER SPACING x 18" ROW SPACING) 15-50 .40 I I AIR/VACUUM RELIEF VALVE (PLUMBS CONNECTION (TYP.) START CONNECTION. HUNTER DRIP LINE - BLANK TUBING (HEADER) - PDL-BLNK-18 I I EACH HIGH POINT ( ) ) SEE PLANS &LEGEND STATE OF 1" CLASS 200 PVC SUB -MAIN LINE FOR DISTRIBUTION TO HEADERS WASHINGTON ( ) I I REGISTERED LANDSCAPE_ RCHITECT AR AIR/VACUUM RELIEF VALVE (PLACED AT HIGH POINT OF ZONE) AR - De LINE FLUSHING VALVE I I . thl a Brad ey 0la DRIP ZONE CONTROL KIT - PCZ-101-40 (INCLUDES CONTROL VALVE, 40 PSI PRESSURE REGULATOR & FILTER) I BLANK TUBING (CENTERED ON MOUE` I o. BERM) , Op TREE DRIPLINE CENTRIC RING NOTE: DESIGN ASSUMES 50 PSI STATIC WATER PRESSURE AT POINT OF CONNECTION AND 30 PSI DESIGNED PRESSURE IRRIGATION REQUIREMENTS: GENERAL NOTES A. IRRIGATION DESIGN ASSUMES XX PSI STATIC WATER PRESSURE IS AVAILABLE ON SITE. VERIFY STATIC WATER PRESSURE IN FIELD PRIOR TO CONSTRUCTION. NOTIFY LANDSCAPE ARCHITECT IF STATIC WATER PRESSURE IS LESS THAN 55 PSI. IRRIGATION DESIGN IS BASED ON 30 PSI. B. USE 4" POP-UP HEADS WITHIN ALL LAWN AREAS AND 6" POP-UP HEADS WITHIN ALL SHRUB AREAS. 12" POP-UP HEADS ARE OPTIONAL IN SHRUB BEDS WITH OWNERS REQUEST. C. RAIN SENSOR TO BE INSTALLED ON SOUTH OR WEST SIDE OF BUILDING, AT A MINIMUM OF 8 FEET ABOVE GRADE WHERE SENSOR IS FREE FROM VANDALISM, TREE CANOPIES, BUILDING OVER HANGS OR OTHER STRUCTURAL / NATURAL RAIN IMPEDIMENTS. COORDINATE LOCATION WITH CONSTRUCTION MANAGER. IRRIGATION NOTES 1. PLAN IS DIAGRAMMATIC. VERIFY LOCATION OF STRUCTURES, UTILITIES AND OTHER SITE ELEMENTS PRIOR TO COMMENCING WORK. NOTIFY PROJECT MANAGER OF ANY CONFLICTS. 2. CONTRACTOR TO TEST EXISTING WATER PRESSURE AN PROVIDE WRITTEN REPORT TO PROJECT MANAGER PRIOR TO COMMENCING WORK. 3. REVIEW ALL IRRIGATION DETAILS PRIOR TO COMMENCING WORK. 4. REFER TO EQUIPMENT SCHEDULE FOR ALL IRRIGATION HEAD TYPES AND EQUIPMENT. 5. PROVIDE 2 (TWO) SPARE WIRES FROM THE CONTROLLER TO THE FURTHEST VALVE LOCATIONS FOR FUTURE EXPANSION. 6. STAKE ALL VALVE BOX LOCATIONS FOR APPROVAL. 7. SET VALVE BOXES SQUARE TO ADJACENT BUILDING, CURB OR PAVING. 8. ALL IRRIGATION UNDER ROADS, WALKS, PARKING AREAS OR OTHER PAVED SURFACES SHALL BE SLEEVED. SLEEVES SHALL BE 2 (TWO) TIMES THE DIAMETER OF THE INSERTED PIPE OR AS INDICATED. 9. ALL PIPING IS DIAGRAMMATIC. PIPING SHOWN WITHIN PAVING OR ADJACENT / PARALLEL TO PLANTED AREAS ARE INTENDED TO BE PLACED WITHIN PLANTING BEDS WHERE POSSIBLE. ALL MATERIAL TO BE INSTALLED ON OWNER'S PROPERTY. 10. MAKE ANY AND ALL REQUIRED ADJUSTMENTS TO THE IRRIGATION PLAN TO ASSURE COMPLETE AN ADEQUATE COVERAGE WITH MINIMUM OVER SPRAY. 11. WHEN SLEEVING, PIPING OR HEAD LAYOUT IS REQUIRED IN R.O.W., CONTRACTOR TO COORDINATE LOCATION WITH THE PROJECT ENGINEER PRIOR TO CONSTRUCTION. INDICATE EXACT LOCATION OF SLEEVES AND PIPING ON THE AS -BUILT DRAWINGS. 12. PLACE TRACE WIRE ON ALL IRRIGATION PIPING AT OWNER'S REQUEST. 13. LATERAL LINE SHALL HAVE MINIMUM 12" OF COVER AND MAINLINES A MINIMUM OF 18" COVER. 14. PROVIDE MANUAL DRAINS AT ALL LOW POINT ON THE MAIN LINE AND RECORD ACCURATELY ON AS -BUILT DRAWINGS. 15. LOCATE IRRIGATION BACK -FLOW PREVENTOR DOWN -STREAM OF SITE WATER METER (WATER METER BY OTHERS). VERIFY LOCATION WITH PROJECT MANAGER PRIOR TO COMMENCING WORK. 16. COORDINATE LOCATION OF CONTROLLER WITH PROJECT MANAGER. INSTALL CONTROLLER AT 60" ABOVE (FINISH FLOOR / FINISH GRADE) ON EXTERIOR WALL OF (BUILDING). PROVIDE A 110 GFI POWER OUTLET AT CONTROLLER LOCATION FOR POWER SUPPLY. PROVIDE CONDUIT FROM IRRIGATION CONTROLLER LOCATION TO OUTSIDE PLANTING BED. FLAG ALL LOCATIONS. VALVE KEY o_ LLI > \ Q N > c) 0 0 1 1" 16 MAX DRIP 2 1" 16 MAX DRIP 3 OPEN OPEN 4 OPEN OPEN 5 OPEN OPEN 6 OPEN OPEN NOTES: 1. INSTALL ACCORDING TO MANUFACTURER'S SPECIFICATIONS 2. CONTRACTOR TO PRICE COMPLETE INSTALLATION UNLESS OTHERWISE INFORMED. End Feed Layout Detail (NOT TO SCALE) LF NOTES TO DESIGNER PVC OR POLY EXHAUST HEADER PERIMETER LATERALS 2" TO 4" FRON PLUMBED TO PVC OR POLY LINE FLU VALVE "END FEED" LAYOUT EDGE OF PAVING SUPPLY HEADER AIR/VACUUM RELIEF VALVE AT HIGH POIN REMOTE CONTROL VALVE ASSEMBLY Techline TUBING ARRANGED TO COVER TRIM AREA EXHAUST HEADER SPRINKLER ON PVC LATERAL IN IDEAL SPACING PATTERN (TYP.) EDGE OF TURF LINE FLUSHING VALVE 1- IN THIS EXAMPLE, IDEAL SPACING IS MAINTAINED FOR THE SPRINKLER SYSTEM W/ OUT DISTORTION, WHILE THE HEADS ARE SET AWAY FROM THE PAVING EDGE TO AVOID OVERSPRAY 2- BLANK Techline TUBING IS USED TO JOIN THE LATERALS ACROSS THE HIGH SPOT TO ENHANCE THE FUNCTION OF THE AIR/VACUUM RELIEF VALVE. 1. INSTALL ACCORDING TO MANUFACTURER'S SPECIFICATIONS 2. CONTRACTOR TO PRICE COMPLETE INSTALLATION UNLESS OTHERWISE INFORMED. Tubing Detail (NOT TO SCALE) n NOTES: 1. INSTALL ACCORDING TO MANUFACTURER'S SPECIFICATIONS 2. CONTRACTOR TO PRICE COMPLETE INSTALLATION UNLESS OTHERWISE INFORMED. 3. CONTACT NETAFIM FOR SPECIFICATIONS AND DETAILS BEFORE INSTALLATION. Sub -Header Installation Detail (NOT TO SCALE) LANDSCAPE DRIPLINE TUBING: HUNTER LANDSCAPE DRIPLINE TIE DOWN STAKE (QTY. AS REQUIRED) TREE TRUNK =SSION TEE REQUIRED) 1/2-INCH POLYETHYLENE TUBING: BLACK STRIPE TUBING NOTE: 1. SEE "LOW -VOLUME LANDSCAPE IRRIGATION DESIGN MANUAL (D39030D) FOR DRIPLINE EMITTER SPACING. 2. QUANTITY OF DRIPLINE RINGS, EMITTER SPACING AND FLOWS ARE DEPENDANT ON TREE CANOPY SIZE. Drip Around Tree Detail (NOT TO SCALE) CITY REVIEW - NOT FOR CONSTRUCTION V I w M Cz z VI 0 LL] Ln z O 0- u) z X Lv U z 00 0, w = w Q w 0 w z � w � Q w LU U = C!1 > Q V >a > LU � Q � z z LIJ m V Q 0� O z O < Q� V (n LL M REVISION No. Date Ey 1 107 Jan 20% YSL Rev. per Site "Ian Changes Scale 1" = 20'-0" Designer Sheet No. YSL Project Manager IR-2 MFW Principal KBR Date of 2 Sheets 16 April 2018 Phase CD Project No. 3.8oi3