HomeMy WebLinkAboutMFP20003916.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP20003916
IVR Number: 20003916
Permit Information
Permit Name: Comcast Cable Franchise Permit
Address/Location:09/02/2020Application Date:2144800548Parcel Number: 8221 S 132ND ST
Permit Type:09/02/2020Issue Date:Franchise
Permit Work Class:09/02/2021Expiration Date:Minor Utility
Job Number: 902764Franchise Type:Cable
Description: Comcast to bore 127' in ROW and place 2" PVC. Begin at CATV Ped NW of 8205's property. bore 37' then bore 11'
under driveway. Bore 26' then bore 3' under sidewalk, bore 11' then bore 13' under driveway. Bore 3' then bore 18'
under road then continue boring 5' to place a 9" flush mount carson box. Pothole all existing utilities. Restoration per
City of Renton standards.
Contacts
Name Address PhoneTypeBilling
Fahm Saelee
Prince Telecom
Applicant
Rhonda Resnik
Comcast
410 Valley Ave NW, Suite 12, Bldg C
Puyallup, WA 98371
B: (253) 864-4246Contact
Tom Donnelly
Comcast Business Communications
1701 Jfk Blvd, 32nd Floor
Philadelphia, PA 19103
B: (215) 286-7347
C: (215) 286-7557
Contact
Akisha Brown
Prince Telecom Inc
551A Mews Dr
New Castle, DE 19720
B: (302) 482-8893
C: (302) 482-8892
Contractor
Business License Number: 29850Electrical Contractor: PRINCTL834BF
Construction Contractor: PRINCTL862PS
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Laurie Dietz
Comcast - Billing
1701 John F. Kennedy Blvd.
Philadelphia, PA 19103
H: (425) 741-5733Specialized
Billing
X
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
RESTORATION PER CITY OF RENTON STANDARDS
POTHOLE ALL EXISTING UTILITIES
Scott Warlick 8/25/2020
MFP20003916
DEPARTMENT OF PUBLIC WORKS
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 1 of 2 | Published: 11/25/2019
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN (TCP) APPLICATION
Published: 11/25/2019
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and
obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
TO THE APPLICANT: Submit the TCP application form and required submittal documents to
TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address.
The following items, electronic copies preferred, are all required for submittal of the TCP Application:
1.! A copy of the Traffic Control Plan (TCP) Application form.
2.! A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall:
!Include map(s) showing the location of the project and work area.
!Be legible lettering and clear, contrasting, symbols of viewing or printing.
!Must indicate street names, and north arrow and scale.
!All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State
Traffic Control Flagger Certification handbook, by the Evergreen Safety Council.
!Types of plans required:
!Work hour plan – show all mobility impacts during construction hours.
!Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
!Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
!Pedestrian access/detour plan, if applicable.
Project Name: ______________________________________________ Permit #: _____________________
Project Address: ____________________________________________________________________________
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Description of Work, Work Schedule, Equipment Used: _____________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
Construction Company: ________________________________________ Phone/Cell: (_____) _____-________
Applicant Name: _________________________________ Email: ______________________________________
Business Address: _________________________________ City/State: __________________ Zip: __________
Approved By: _______________________________________________ Date: ________________________
Transportation Operations Engineering
Comcast Job 902764
8221 S 132nd ST Renton
Monday Friday 8:00AM 3:00PM
Bore 127' in r/w and place
2" PVC.
Prince Telecom LLC 253 891 2899
Comcast Cable Communications Management, LLC rhonda_resnik@comcast.com
410 Valley Ave NW Ste:12 Bldg C Puyallup, WA 98371
Scott Warlick CED 8/25/2020
MFP20003916
POTHOLE ALL EXISTING UTILITIESRESTORATION PER CITY OF RENTON STANDARDSMFP20003916
8205
8221
Road bore
SWB
Drive way
bore
<18'><26'>CATVped
Drive waybore
<5'><3'><13'><11'>carsonset<3'><11'><37'>
KENNY"S TRAFFIC ZONE PLANS
Kenny Stertz
Longview , Watraficplayr@aol.comTCS # 5663
NORTH
NOT TO SCALE
cones -
flagger -ROADWORKAHEADW20-1 W20-7aW20-4
350'
A B C
ONE LANEROADAHEAD350'350'
SIGN SPACING = X (FEET) (1)
FREEWAYS & EXPRESSWAYS
RURAL HIGHWAYS
RURAL ROADS
RURAL ROADS and URBAN ARTERIALS
RURAL ROAD, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS
ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED
55/70 mph
60/65 mph
45/55 mph
35/40 mph
25/30 mph
25mph or less
1500ft +/-
800ft +/-
500ft +/-
350ft +/-
200ft +/-(2)
100ft +/-(2)
(1) All spacing may be adjusted to accomodate interchange ramps, at-gradeintersections, and driveways.
(2) This spacing may be reduced in urban areas to fit roadway conditions.
MERGING, SHIFTING, and SHOULDER TAPER LENGTHS
and NUMBER OF CHANNELIZATION DEVICES USED
10ft LANE 11ft LANE 12ft LANE
L L L1/2L 1/2L 1/2L
Lanewidth
MPH Merging Merging MergingDevicesShiftingDevicesDevicesDevicesDevices DevicesShiftingShifting
SHOULDER TAPERS(assume 10ft shoulders)
1/3L Devices(FT)LengthMPH
2025
3035404550
55606570
70105150205270
450500550600650700
66
8810
161415
161719
355575105135
225250275
300325350
34556
9889910
75115165225295495550605660715770
679
911181516181920
406085115
150250285305330370385
3455
698
991011
80125180245
320540600660720780840
67109121916
18192122
4065
90125160270300330360390420
345561099
101112
2025
3035404550556065
70
2535
507090
150170185
200220235
33344
666677
Shoulder tapers equalsshoulder Width x Speed/3
MINIMUM TAPER LENGTH = L (feet)
POSTED SPEED (mph)25 30 35 40 45 50 55 60 65 70
LANEWIDTH(feet)
10
1112
105
115125
150
165180
205
225245
270
295
320
450
495
540
500
550
600
550
605
660
660
720
-----780 840
TYPICAL PROTECTIVEVEHICLE TYPEWITH TMA
TYPICAL PROTECTIVE VEHICLE(WITH TMA) LOADED WEIGHT(LBS)
STATIONARYOPERATION(ft)
30 MIN.
100 max.
MINUMIM WEIGHT 16000 LBS(MAXIMUM WEIGHT SHALL BE IN ACCORDANCEWITH MANUFACTURER RECOMMENDATION
4 YARD DUMP TRUCKSERVICE TRUCKFLAT BED, ETC
PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCE
LONGITUDINAL BUFFER SPACE = B
ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT
A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF A TMA IS AVAILABLE IF NO TMA IS USED,THE PROTECTIVE VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO SHIELD WORKERS ANDNO ROLL AHEAD DISTANCE IS SPECIFIED. REFER TO CHAPTER 1.5.5 FOR ADDITIONAL INFORMATION
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (mph)
LENGTH (ft)
25 30 35 40 45 50 55 60 65 70
155 200 250 305 360 425 495 570 645 730
CHANNELIZING DEVICE SPACING CHART (FEET)
50/70
35/45
20/30
mph *Half-Spacing*TAPER TANGENT
20
N/A
40
30
20
80
60
40N/A
Prince telecom
telecommunications
installation
Fahm Salee
253-891-2899
JOB # CSG 902764
S 132nd St W20-7aC350'350'ROADWORKAHEAD
W20-1W20-7bABBE PREPAREDTO STOP
350'35
0
'ROADWORKAHEADW
2
0
-1W
2
0
-7b
AB
BE PREPAREDTO STOP35
0
'
Re
n
t
o
n
Ave
s
shoulder
shoulder
www.invarion.com
MFP20003916