Loading...
HomeMy WebLinkAboutP_Civil_Existing_190723273' 272' 230'VVCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACT COMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACTCOMPACT3 C3. 1 1 C3.1 2C3.14 C3.11C3.21C3.22,3,4C3.2Know what's below. before you dig.Call R 0'50'25' 1"=50' 100'N IN COMPLIANCE WITH CITY OF RENTON STANDARDSTED-40-4042PROLOGIS RENTON 9 601 MONSTER ROAD SWPROLOGIS RENTON 9LUA 18-000237C18-006309PROLOGIS RENTON 9PR18-00015512720 Gateway Dr., Suite 110 Tukwila, WA 98168 206-414-7625 Client: 950 Pacific Avenue, Suite 450 Tacoma, WA 98402 253-572-4903 REUSE OF DOCUMENTS GENERAL NOTES: 601 MONSTER ROAD SW A PORTION OF THE NW 1/4 OF SECTION 24, TOWNSHIP 23, RANGE 4 E., W.M. CITY OF RENTON, KING COUNTY, WASHINGTON PROLOGIS RENTON 9 SANITARY SEWER, WATER & FIRE PLAN COMPOSITE STORMWATER, DRY UTILITIESC5.0R-404216W-404203 S-404203 CROSSING TABLE CROSSING #FINISHED GRADE PIPE 1 PIPE 2 DIFF 1 26.40 12" DI WATER 8" PVC SEWER IE=20.60 CROWN=19.27 1.33' 2 26.19 8" CPEP STORM 8" PVC SEWER IE=22.85 CROWN=19.42 3.43' 3 26.32 12" DI WATER 8" DI STORM CROWN=21.42 IE=22.67 1.25' 4 27.81 12" DI WATER 18" CPEP STORM IE=22.71 CROWN=21.44 1.27' 5 26.41 12" DI WATER 18" CPEP RD IE=21.31 CROWN=20.59 0.72' * 6 25.26 12" DI WATER 8" CPEP STORM CROWN=21.26 IE=21.69 0.43' * 7 26.23 8" CPEP STORM 18" CPEP RD IE=20.96 CROWN=19.47 1.49' 8 29.69 12" DI WATER 18" CPEP STORM IE=23.36 CROWN=22.36 1.00' 9 26.46 2" DOMESTIC WATER 12" CPEP STORM IE=24.21 CROWN=23.13 1.08' 10 31.46 12" DI WATER EX. 10" STORM ADS CROWN=25.56 IE=27.08 1.52' 1 2 3 5 6 8 7 2.0" DOMESTIC AND 1.5" IRRIGATION METER1 * MINIMUM REQUIRED VERTICAL SEPARATION BETWEEN UTILITY PIPES AT CROSSING IS 1.0 FEET. ETHOFOAM PAD SHALL BE PROVIDED BETWEEN UTILITIES PIPES AT CROSSINGS WHERE THE 1.0 FOOT VERTICAL SEPARATION IS NOT AVAILABLE. 1 C5.0 10 9 WATER KEY NOTES: 4 KEY NOTES: 1 RELOCATE EXISTING UTILITY VAULT. COORDINATE WITH UTILITY PURVEYOR. APPROXIMATE RELOCATION SHOWN SUBJECT TO FINAL UTILITY PURVEYOR APPROVAL. SEE SHEET C6.0 FOR LOCATIONS. 2 REMOVE EXISTING POWER POLE. SEE GENERAL NOTE #1, THIS SHEET. 3 REFER TO BMP NOTES, KEYNOTE #12 AND DETAIL 4 ON SHEET C5.2 FOR SOIL CONDITIONS AND EXCAVATION WITHIN THIS AREA. 3 1 1 2 2 2 4 4 REFER TO BMP NOTES, KEYNOTE #13 AND DETAIL 5 ON SHEET C5.2 FOR SOIL CONDITIONS AND EXCAVATION WITHIN THIS AREA. 11 12 13 14 11 28.61 6" DI WATER 18" CPEP STORM IE=24.03 CROWN=22.54 1.49' 12 26.84 12" DI WATER 12" CPEP STORM CROWN=22.84 IE=23.58 0.74' 13 28.08 6" DI WATER 18" CPEP STORM CROWN=20.91 IE=21.41 0.50' 14 27.75 12" DI WATER 18" CPEP STORM CROWN=20.97 IE=21.47 0.50' WASTEWATER UTILITY dchristen 07/29/2019 SURFACE WATER UTILITY jfarah 07/29/2019 DEVELOPMENT ENGINEERING rnair 07/31/2019 WATER UTILITY agafour 07/31/2019