GENERAL NOTES:
601 MONSTER ROAD SW
A PORTION OF THE NW 1/4 OF SECTION 24,
TOWNSHIP 23, RANGE 4 E., W.M.
CITY OF RENTON, KING COUNTY, WASHINGTON
PROLOGIS RENTON 9
SANITARY SEWER, WATER & FIRE PLAN
COMPOSITE STORMWATER, DRY UTILITIESC5.0R-404216W-404203
S-404203
CROSSING TABLE
CROSSING #FINISHED GRADE PIPE 1 PIPE 2 DIFF
1 26.40 12" DI WATER 8" PVC SEWER
IE=20.60 CROWN=19.27 1.33'
2 26.19 8" CPEP STORM 8" PVC SEWER
IE=22.85 CROWN=19.42 3.43'
3 26.32 12" DI WATER 8" DI STORM
CROWN=21.42 IE=22.67 1.25'
4 27.81 12" DI WATER 18" CPEP STORM
IE=22.71 CROWN=21.44 1.27'
5 26.41 12" DI WATER 18" CPEP RD
IE=21.31 CROWN=20.59 0.72' *
6 25.26 12" DI WATER 8" CPEP STORM
CROWN=21.26 IE=21.69 0.43' *
7 26.23 8" CPEP STORM 18" CPEP RD
IE=20.96 CROWN=19.47 1.49'
8 29.69 12" DI WATER 18" CPEP STORM
IE=23.36 CROWN=22.36 1.00'
9 26.46 2" DOMESTIC WATER 12" CPEP STORM
IE=24.21 CROWN=23.13 1.08'
10 31.46 12" DI WATER EX. 10" STORM ADS
CROWN=25.56 IE=27.08 1.52'
1
2
3
5
6
8
7
2.0" DOMESTIC AND 1.5" IRRIGATION METER1
* MINIMUM REQUIRED VERTICAL SEPARATION BETWEEN UTILITY PIPES AT CROSSING IS 1.0 FEET.
ETHOFOAM PAD SHALL BE PROVIDED BETWEEN UTILITIES PIPES AT CROSSINGS WHERE THE 1.0 FOOT
VERTICAL SEPARATION IS NOT AVAILABLE.
1
C5.0
10
9
WATER KEY NOTES:
4
KEY NOTES:
1 RELOCATE EXISTING UTILITY VAULT.
COORDINATE WITH UTILITY PURVEYOR.
APPROXIMATE RELOCATION SHOWN SUBJECT
TO FINAL UTILITY PURVEYOR APPROVAL. SEE
SHEET C6.0 FOR LOCATIONS.
2 REMOVE EXISTING POWER POLE. SEE
GENERAL NOTE #1, THIS SHEET.
3 REFER TO BMP NOTES, KEYNOTE #12 AND
DETAIL 4 ON SHEET C5.2 FOR SOIL CONDITIONS
AND EXCAVATION WITHIN THIS AREA.
3
1
1
2
2
2
4
4 REFER TO BMP NOTES, KEYNOTE #13 AND
DETAIL 5 ON SHEET C5.2 FOR SOIL CONDITIONS
AND EXCAVATION WITHIN THIS AREA.
11
12
13
14
11 28.61 6" DI WATER 18" CPEP STORM
IE=24.03 CROWN=22.54 1.49'
12 26.84 12" DI WATER 12" CPEP STORM
CROWN=22.84 IE=23.58 0.74'
13 28.08 6" DI WATER 18" CPEP STORM
CROWN=20.91 IE=21.41 0.50'
14 27.75 12" DI WATER 18" CPEP STORM
CROWN=20.97 IE=21.47 0.50'
WASTEWATER UTILITY
dchristen 07/29/2019
SURFACE WATER UTILITY
jfarah 07/29/2019
DEVELOPMENT ENGINEERING
rnair 07/31/2019
WATER UTILITY
agafour 07/31/2019