HomeMy WebLinkAboutR-4130L01L
C
L
L
❑ripllne
I
I
1 x`
1 �
Critical
y Root Zo
RWfS r
One sign per 50 feet
(minimum of 7 signs) '
14 Ft.
Y-4--D
o
W
Q
W
Z
m
TREE PROTECTION FENCE DETAIL.
M
I
I
I
I
I
I
I
6 Ft. Temporary
Chain Link Fence
• • 1
PROTECTED
TREES
TREE REPLACEMENT/STREET TREE PLAN
NOTES
1. 6—FOOT HIGH TEMPORARY CHAIN LINK FENCE SHALL BE PLACED AT
THE ❑RIPLINE OF THE TREE TO BE SAVED. FENCE SHALL COMPLETELY
ENCIRCLE THE TREE(S). INSTALL FENCE POSTS USING PIER BLOCKS
ONLY. AVOID DRIVING POSTS OR STAKES INTO MAJOR ROOTS.
2. FOR ROOTS OVER 1—INCH IN DIAMETER THAT ARE DAMAGED DURING
CONSTRUCTION, MAKE A CLEAN, STRAIGHT CUT TO REMOVE THE
DAMAGED PORTION. ALL EXPOSED ROOTS SHALL BE TEMPORARILY
COVERED WITH DAMP BURLAP TO PREVENT DRYING, AND SHALL BE
COVERED WITH SOIL AS SOON AS POSSIBLE.
3, WORK WITHIN PROTECTION FENCE SHALL BE DONE MANUALLY, NO
STOCKPILING OF MATERIALS, VEHICULAR TRAFFIC, OR STORAGE OF
EQUIPMENT OR MACHINERY SHALL BE ALLOWED WITHIN THE LIMIT OF
THE FENCING.
N 33RD PL
1 O' ON SITE PLANTING AREA AND PLANTING STRIP PLAN
1 I
NEW S' CONC SyDEWALK VERIFY I
76
ITH CIVIL -DRAWINGS �
110' REQUIRED STREET FRONTAGE I I
ILANDSiAPE AREA I
t RE UIRED RIGHT OF WAY I
I LAIDSCAPE AREA I
I SIGNIFICANT TREES, TO BE I I
REMOVED I
LOT 2
w
1 � 1
I
i
1 "=10'-0"
0 5 10 20
Print Form Reset Form Save Form
DEPARTMENT OF COMMUNITY C.TYoF PER MINIMUM TREE LOT DENSITY CALCULATIONS
Renton
AND ECONOMIC DEVELOPMENT LOT ONE REQUIRES 2.24 TREES ON THE LOT, 4 PROVIDED
LOT TWO REQUIRES 1.84 TREES ON THE LOT, 2 PROVIDED.
TREE RETENTION WORKSHEET
Planning Division
1055 South Grady Way -Renton, WA 98057
Phone: 425-430-7200 1 www.rentonwa.gov
1. Total number of trees over 6" diameter', or alder or cottonwood
trees at least 8" in diameter on project site 3
trees
2. Deductions: Certain trees are excluded from the retention calculation:
Trees that are dangeroUS 0
trees
Trees in proposed public streets 0
trees
Trees in proposed private access easements/tracts 0
trees
Trees in critical areas3 and buffers 0
trees
Total number of excluded trees: 0
trees
3. Subtract lure 2 from line 1: 3
trees
4. Next, to determine the number of trees that must be retained4, multiply line 3 by:
0.3 in zones RC, R-1, R-4, R-6 or R-8
0.2 in all other residential zones
0.1 in all commercial and industrial zones 1
trees
5. List the number of 6" in diameter, or alder or cottonwood trees
over 8" in diameter that you are proposings to retain: 0
trees
6. Subtract fine 5 from line 4 for trees to be replaced:
(if line 6 is zero or less, stop here. No replacement trees are required) 1
trees
7. Multiply line 6 by 12" for number of required replacement inches: 12
inches
8. Proposed size of trees to meet additional planting requirement:
(Minimum 2" calipertrees required) 2
inches per tree
9. Divide line 7 by fine 8 for number of replacement treesb:
(If remainder is .5 orgreater, round up to the next whole number) 6
trees
1 Measured at 4.5' above grade.
A tree certified, in a written report, as dead, terminally diseased, damaged, or otherwise dangerous to persons or property
by a licensed
landscape architect, or certified arborist, and approved by the City.
L
Critical areas, such as wetlands, streams, floodplains and protected slopes, are defined in RMC4-3-1750.
4Count
onlythose treesto beretainedoutside of critical areas and buffers.
sThe City may require modification ofthe tree retention plan to ensure retention ofthe maximum number of trees per RMC 4-4-130H7a.
n When the required numberof protectec trees cannot be retained, replacement trees, with at least a two-inch (2") caliper oran evergreen at least
r
sixfeet (C) tall, shall be planted. See RMC 4-4-130.H.1.e.(ii) for prohibited types of replacement trees.
1
r�
H:4CEDNData\Forms-Templates\Self-Help Han doutsjPlanning\Tree Retention Worksheet.docx
08/2015
NOTE:
A MINIMUM OF 30 PERCENT TREE
RETENTION IS REQUIRED. TREE
PROTECTION REQUIRED PER RMC
4-4-130
Q
0
TREE PLANT SCHEDULE
QUANT.
BOTANICAL NAME
COMMON NAME
SIZE
'Princess Diana'
6
Amelanchier arandiflora
2" CAL
STREETTREE FORM, MINIMUM BRANCH HT. 6'
3
PYRUS CHANTICLEER
CHANTICLEAR FLOWERING PEAR
2" CAL
STREET TREE FORM, MINIMUM BRANCH HT. 5'
2
THUJA PLICATA EXCELSA
EXCELSA WESTERN RED CEDAR
6-T
2" CALIPER MINIMUM, UPSIZE IN HEIGHT IF NECESSARY
* REPLACEMENT TREE
SHRUB and CR❑UNDC❑VER PLANT SCHEDULE
QUANT.
BOTANICAL NAME
COMMON NAME
SIZE
SPACING/HT.
8
ARBUTUS UNEDO COMPACTA
COMPACT STRAWBERRY BUSH
2 GAL
300
ARCTOSTAPHYLLOS UVA URSI
KINNIKINNICK MASSACHUSETTS
1 GAL
301, O.C.
16
CORNUS STOLONIFERA MIDWINTER FIRE
MIDWINTER FIRE REDTWIG DOGWOOD
2 GAL
41
MAHON IA AQUAFOLIUM COMPACTA
COMPACTA OREGON GRAPE
2 GAL
11
MISCANTHUS YAKU JIMA
YAKU JIMA SEMI DWARF MAIDEN GRASS
2 GAL
11
PENNISETUM HAMELN
DWARF FOUNTAIN GRASS
2 GAL
30
PINUS MUGO PUMILIO
DWARF MU GO PINE
2 GAL
15
POTENTILLA'MANGO TANGO'
MANGO TANGO POTENTILLA
2 GAL
10
PRUNUS MT. VERNON
MT. VERNON LAUREL
1 GAL
19
PRUNUS L.'OTTO LUYKEN'
OTTO LUYKEN LAUREL
2 GAL
4
VIBURNUM P.T. SUMMER SNOWFLAKE
SUMMER SNOWFLAKE VIBURNUM
2 GAL
PROVIDE QUANTITIES AS SHOWN ON PLAN OR AS LISTED IN SCHEDULE WHICHEVER IS GREATER
GROUNDCOVERS TO BE PLANTED A MINIMUM OF 16" FROM PAVED SURFACES
STREET TREES TO BE STREET TREE FORM AND BRANCHED AT A MINIMUM OF 6' HEIGHT
PROVIDE 5' HORIZONTAL CLEARANCE BETWEEN TREES AND UNDERGROUND UTILITIES
IA
URRENT PLANNING
ngelea Weihs 07/23/2019
J
m
co
0 ¢
w
0
0
LU CA
0
cv
0
z r-I
d9a I
GHA Laridscape Architects
14-17 NE 80th 5t,
SEATTLE, WA 98115
TELE 2D6.522.2334 FAX 206.526.5667
[C] GHA Landscape Archltects 2016
W
�
0
J
b
�
�
Q
W
WzW<>
W
o
LLJ
W
<0�
WCLLLZ
J
=
W
oo
=
w
Ctil
Q
W
W
ZD
W
(Y)
CLIENT
STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT
N IL aUCHANAN
CERTIFICATE No. 513
PROJECT NO.
DRAWING
L1.01
SHEET 1 OF 2