Loading...
HomeMy WebLinkAboutMFP19006530.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP19006530 IVR Number: 19006530 Permit Information Permit Name: Comcast Cable Franchise Permit Address/Location:12/09/2019Application Date:7231502085Parcel Number: 710 S 2ND ST Permit Type:10/23/2020Issue Date:Franchise Permit Work Class:10/23/2021Expiration Date:Major Utility Job Number: JB#59934Franchise Type:Cable Description: Comcast is proposing to proof 4,150' of existing conduit; place 4,750' of 288ct; bore 144' and place 2(2") conduits across N 3rd and Meadow Ave N; bore 2212' from N 4th St and meadow Ave to Sunset Blvd N; overlash 11,720'; set new node cabinet; place 3 new pedistals on N 4th St for new pull locations. Pothole all existing utilities. Restoration per City of Renton standards. Contacts Name Address PhoneTypeBilling Comcast Cable Communication Management & Comcast Cable B: (215) 665-1700Applicant Ashley Kiehn Sefnco Communications Applicant Tom Donnelly Comcast Business Communications 1701 Jfk Blvd, 32nd Floor Philadelphia, PA 19103 B: (215) 286-7347 C: (215) 286-7557 Contact Scott Nall SEFNCO Communications Inc 2904 4th Ave NE Puyallup, WA 98372 B: (877) 385-2903 C: (253) 444-9057 Contractor Business License Number: 41108Construction Contractor: SEFNCCI850QD Scott Nall SEFNCO Communications Inc 2904 4th Ave NE Puyallup, WA 98372 B: (877) 385-2903 C: (253) 444-9057 Contractor Business License Number: 41108Construction Contractor: SEFNCCI850QD CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 H: (425) 741-5733Specialized Billing X General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 | Published: 3/30/2017 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 3/30/2017 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street ☐ Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date Justin Johnson Scott Warlick 10/22/2020 10/22/2020 RESTORATION PER CITY OF RENTON STANDARDS MFP19006530 POTHOLE ALL EXISTING UTILITIES This permit is for Major construction work in the ROW and will be billed at an additional $60/HR for inspections. After hours and weekend work will be billed at $125/HR CITY OF RENTON TRAFFIC CONTROL PLAN PROJECT NAME: PERMIT# CONSTRUCTION COMPANY: PHONE#: CONTACT NAME: PHONE#: ADDRESS: CELL#: E-MAIL ADDRESS: FAX#: PROJECT LOCATION: N/E/S/W OF: WORK TIME: APPROVED BY: WORK DATE: APPROVAL DATE: OFFICE COPY T- CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER DEV. SERVICE, PLAN REVIEW B. BANNWARTH POLICE CHARLES KARLEWICZ FIRE FIRE MARSHALL FS #13 Permit Holder agrees to all the following: • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • By my signature herein, I acknowledge all the above requirements. PRINT NAME: DATE: SIGNATURE: STEFANIA SPENCER, PERMIT COORDINATOR 10-15/2020 MFP19006530 Monday - Friday 10/22/2020 Justin Johnson SKETCH I -- NORTH -- I NOTES: • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by sketch or reference to WSDOT. • The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three working days prior to work. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded. • Total road closure lasting more than 24 hours is subject to the approval by the City Council. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block 72 hours in advance of effective date and time. • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). MFP19006530 MFP19006530 MFP19006530 MFP19006530 MFP19006530 MFP19006530 MFP19006530 MFP19006530 MFP19006530 MFP19006530 MFP19006530 MFP19006530 MFP19006530 MFP19006530 MFP19006530 © 2019 Microsoft Corporation © 2019 HERE POLE-1 POLE-2 POLE-4 POLE-6 POLE-5 POLE-7 POLE-8 POLE-9 POLE-11POLE-10 POLE-12 POLE-13 POLE-14 POLE-15 POLE-16 POLE-17 POLE-18 POLE-19 POLE-20 POLE-21POLE-22 POLE-23 POLE-24 POLE-25 POLE-26 POLE-27 POLE-28 P P P POLE-29 POLE-30 POLE-31 POLE-32 POLE-33 POLE-34 POLE-35 POLE-36 POLE-37 POLE-38 POLE-39 POLE-40 POLE-41 POLE-42 POLE-43 POLE-44 POLE-45 POLE-46 POLE-47 POLE-48 POLE-49 POLE-50 POLE-51 POLE-52 POLE-53 POLE-54 POLE-55 POLE-56 POLE-57 POLE-58 POLE-59 POLE-60 POLE-61 POLE-62 POLE-63 POLE-64 POLE-65 POLE-66 POLE-67 POLE-68 POLE-69 POLE-70 POLE-71 POLE-72 POLE-73 POLE-74 POLE-75 POLE-76 POLE-77 POLE-78 POLE-79 POLE-80 P P P P SP.WAKV.0691 CROSS OVERPOLE-3 XXXXX CROSS OVER POLESP.WAKV.0851 SP.WAKV.0850 SHEET INDEX: 1 - COVER SHEET 2 - LEGEND SHEET 3 - NOTES 4-42 -DESIGNTHIS IS PROPRITORY INFORMATION AND NOT MEANT FOR GENERAL PUBLICATION. ALL RIGHTS RESERVED SEFNCO COMMUNICATIONS PROJECT MAP: COVER "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN1 42 WORK AREA COMCAST AARON CANTREL 410 VALLEY AVE PUYALLUP, WA 98371 206-510-4222 AARON_ CANTREL@COMCAST.COM CONTACTS SEFNCO JENNIFER GREINKE 4610 TACOMA AVE. SUMNER, WA 98390 253-258-1243 JEGREINKE@sefnco.com COMCAST COMCAST PROJECT DESCRIPTION* *ALL FOOTAGES AND MATERIALS ARE ESTIMATED = = = = = = = ·PROOF/PULL 288CT FIBER THRU EXISTING CONDUIT. ·OVERLASH 288CT FIBER TO EXISTING STRAND. TOTAL: revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 4750 LN FT 11720 LN FT 16470 LN FT RN03B NEW NODE RN60 710 S 2ND ST RENTON, WA. JB# 59934 MFP19006530 LEGEND "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN2 42 STORM DRAIN MANHOLE COMMUNICATIONS WATER SEWER POWER GAS ROW R PROPOSED VAULT PROPOSED BORE PIT STREET/SIGNAL/TRAFFIC LIGHT CATCH BASIN FIRE HYDRANT EXISTING POLE W/ NEW RISER TRAFFIC FLOW CHANNELIZATION (xxx') OPEN TRENCH .25 SIDEWALKS / DRIVEWAYS 1.0 EXISTING PULL THRU 1.0 PROPOSED BORE .50 PROPOSED OPEN TRENCH (xxx') EXISTING PULL THRU (xxx') BORE SIDEWALKS / DRIVEWAYS.50 RIGHT-OF-WAY .50 CENTERLINE .50 TRAFFIC LANE .25 FENCE D CB S C .25 GAURD RAIL .50 AERIAL STRAND LEGEND V U U U U U U U U U S W P C G D EOP .25 EDGE OF PAVEMENT POLE AERIAL STRAND OVERLASH 1.0 OVERLASH COMCAST RE-CLAIMED WATERWF CONSTRUCTION NOTE EXISTING VAULT V BUILDING OUTLINE POTHOLE LOCATION PROPOSED PEDESTALP P EXISTING PEDESTAL revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MH MFP19006530 NOTES & LEGEND "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN3 42 FIBER PLACEMENT NOTES:GENERAL NOTES: DISCLAIMER: 1.IT IS THE RESPONSIBILITY OF THE CONSTRUCTION CONTRACTOR TO VERIFY ALL RIGHT OF WAY BEFORE CONSTRUCTION IS TO BEGIN. NO UNDERGROUND INSTALLATION REPRESENTED WITHIN THESE PLAN SHEETS IS PROPOSED OUTSIDE OF THE RIGHT OF WAY. 2.THE UNDERGROUND ROUTE DEPICTED IS PRELIMINARY AND WILL/MAY VARY ONCE UTILITIES HAVE BEEN FIELD LOCATED. 3.ANCHORING FOR THE AERIAL CONSTRUCTION IS TYPICALLY DETERMINED DURING CONSTRUCTION AND IS COLLECTED IN THE AS-BUILT PHASE. 1.CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES 48 HOURS PRIOR TO CONSTRUCTION ACTIVITY SEE LOCAL DIRECTORY FOR CONTACT TELEPHONE NUMBER OF LOCAL CALL BEFORE YOU DIG AGENCY. 2.CONTRACTOR SHALL RECORD SEQUENCE # OF FIBER CABLE AT EVERY WORK POLE, MANHOLE, FIBER STORAGE LOOP AND TAIL LOCATION. CONTRACTOR TO PROVIDE PROJECT MANAGER WITH SEQUENCE NUMBERS AT PROJECT COMPLETION. 3.SLACK LOOP AND SNOWSHOE STORAGE LOCATIONS SHALL BE DETERMINED ON CONSTRUCTION DRAWINGS, HOWEVER, REEL LENGTHS OF FIVE HUNDRED FEET (500') OR LESS ON LARGE COUNT FIBER OR THREE HUNDRED FEET (300') OR LESS ON SMALL COUNT FIBER ARE DIFFICULT TO USE AND SHOULD BE PLACED AS FSL'S, NOT CUT AND RETURNED. 4.FIBER OPTIC IDENTIFICATION TAGS SHALL BE PLACED AT EVERY WORK POLE, MANHOLE, FIBER, STORAGE LOOPS, SPLICE CASES AND WHERE INDICATED BY PROJECT MANAGER. TAGS NEED TO BE PLACED SO AS TO BE READ FROM THE GROUND. 5.CABLE LUBRICATION SHALL BE USED TO REDUCE PULLING TENSION. LUBRICANTS MUST NOT CONTAIN ANY PETROLEUM PRODUCTS. 6.A 100 FOOT FIBER COIL MUST REMAIN IN ALL VAULTS UNLESS OTHERWISE NOTED. 7.ALL BURIED INFRASTRUCTURE MUST BE ACCOMPANIED WITH WARNING TAPE AND A TRACER WIRE, AT RISER POLES THE LOCATE WIRE SHALL BE ACCESSIBLE AT THE BASE OF THE RISER. 8.ALL RISERS WILL BE CAPPED AT ALL TIMES. 9.ALL FIBER SHALL BE MARKED AS TO DIRECTION IN EACH VAULT. RED-NORTH, GREEN-SOUTH,YELLOW-EAST, AND BLUE-WEST. DO NOT TAPE FIBER CABLES TOGETHER IN RISER. 1. ALL VAULTS / HANDHOLES TO BE EQUIPPED WITH SECURITY LIDS WITH LOCKING BOLTS. 2. GROUND RESTORATION/RIGHT-OF-WAY SHALL BE RESTORED TO ORIGINAL OR BETTER CONDITION. 3. ALL 90 DEGREE BENDS IN CONDUIT CONSTRUCTION WILL BE A MINIMUM OF 36" RADIUS UNLESS SPECIFIED OTHERWISE. 4. BURIED FIBER OPTIC WARNING SIGNS SHALL BE PLACED AT EACH SIDE OF ALL ROAD CROSSINGS, AT CULVERTS, DITCHES AND IN A STRAIGHT LINE OF SIGHT SPACING OF APPROXIMATELY 500 FEET. 5. DEVIATIONS FROM THE ENGINEERED ROUTE REQUIRES A PROJECT MANAGER AND RIGHT-OF-WAY OWNER OR CARETAKER APPROVAL PRIOR TO CONSTRUCTION. 6. WHERE PERMITS FROM STATE, COUNTY, CITY, RAILROAD OR GOVERNMENT AGENCIES ARE REQUIRED, ALL WORK PERFORMED WILL COMPLY WITH THESE AGENCIES STANDARD SPECIFICATIONS. 7. THE PROJECT MANAGER WILL NOTIFY BUILDING MANAGEMENT WHEN WORK WILL BEGIN ON BUILDING. CONTRACTOR TO COORDINATE ROOM ACCESS AND WORK START AND STOP TIMES WITH BUILDING MANAGEMENT. 8. THE PROJECT MANAGER IS TO BE NOTIFIED BY THE CONTRACTOR 24 HOURS PRIOR TO CONSTRUCTION. SEE COMPANY CONTACT LIST FOR CONTACT NAME(s) AND TELEPHONE NUMBER(s). 9. THE PROJECT MANAGER WILL RESERVE THE RIGHT TO INSPECT AT ANY TIME THE WORK BEING PERFORMED BY THE CONTRACTOR. IF PROJECT MANAGER DETERMINES THAT THE WORK IS NOT BEING PERFORMED TO MINIMUM QUALITY STANDARDS, THEN THE CONTRACTOR SHALL PROVIDE REWORK AT HIS OWN COST. 10. ANY CHANGE IN PROJECT SCOPE, INCLUDING BUT NOT LIMITED TO, CONDUIT LENGTH, CONDUIT PATH, AERIAL PATH ETC., MUST BE APPROVED BY THE PROJECT MANAGER. 11. ALL CORING/CONSTRUCTION THAT WILL CAUSE NOISE AND/OR VIBRATION SHALL BE DONE WITHIN ALLOWED (9AM-3PM) BUSINESS HOURS. 12. ANY AND ALL UNDERGROUND UTILITIES ENCOUNTERED ARE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE, PROTECT, AND REPAIR, IF DAMAGED. 13. ALL FOOTAGES ARE BASED ON FIELD GATHERED MEASUREMENTS, AS SUCH SOME VARIANCE SHOULD BE ANTICIPATED. ADJUST AS NEEDED. 14. ALL BURIED CONDUIT/CABLE WILL BE PLACED AT 36" MINIMUM COVER. SITE HAS POTENTIAL FOR ROCK THAT WOULD PREVENT THE ABILITY TO PROVIDE THE MINIMUM COVER. IN CASES WHERE THE MINIMUM COVER CAN NOT BE ACHIEVED, THE CONDUIT SHALL BE PLACED IN A SCH 40 EMT SLEEVE OR APPROVED EQUIVALENT. 15. WATER, SEWER, STORM SEWER AND EASEMENT LOCATIONS ARE BASED OFF OF CITY MAPS, NOT FIELD VERIFIED. 16. BORING OF AC PAVING IS REQUIRED AT ALL LOCATIONS AS INDICATED ON PLANS. 17. AT NO TIME SHALL CURBS, GUTTERS OR HANDICAP BE DISTURBED. 18.DOOR HANGERS ARE TO BE PLACED A MINIMUM OF 72 HOURS PRIOR TO START OF CONSTRUCTION. 19. PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL PLACE MESSAGE BOARDS STATING LANE CLOSURES, AND DELAYS A WEEK IN ADVANCE. LOCATION OF THE MASSAGE BOARD SHALL BE COORDINATED WITH THE CITY INSPECTOR AT THE PRE-CONSTRUCTION MEETING. 20. LANE CLOSURES CANNOT EXCEED MORE THAN 300 FT. AT A TIME. FOR SAFETY PURPOSES THERE SHALL BE ONLY ONE CLOSURE AT A TIME ALONG INTERNATIONAL BLVD. MORE FLAGGERS WILL BE NECESSARY TO HELP VEHICLES AND PEDESTRIANS IN THE WORK ZONES DURING THE LANE CLOSURES.COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MFP19006530 ROWROWROW ROWROW ROWEOPEOPEOPEOPEOPEOPEOPEOPEOP207'ONE WAYONE WAYONE WAYWILLIAMS AVE SWILLIAMS AVE S710 SIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALKDRIVEWAY DRIVEWAY38'"DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN4 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 TIE IN TO EXISTING VAULT. PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. EXISTING VAULT. EXISTING VAULT. MATCH-LINE-SHEET-5 MATCH-LINE-SHEET-4 MFP19006530 ROWEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPONE WAYONE WAYONE WAYWILLIAMS AVE SWILLIAMS AVE SWILLIAMS AVE SSIDEWALKSIDEWALKDRIVEWAY DRIVEWAY DRIVEWAY DRIVEWAY DRIVEWAY DRIVEWAY DRIVEWAY DRIVEWAY DRIVEWAY DRIVEWAY 187'SIDEWALKSIDEWALK"DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN5 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. EXISTING VAULT. EXISTING VAULT. MATCH-LINE-SHEET-5 MATCH-LINE-SHEET-4 MATCH-LINE-SHEET-6 MATCH-LINE-SHEET-5 MFP19006530 ROW ROW ROW ROWROWROWROW ROWR O W R O W ROWROWROWROWEOPEOPEOPEOPE O P E O P E O PEOP ONE WAYONE WAYWILLIAMS AVE SWILLIAMS AVE SEOPEOPEOPEOPEOPEOPS TOBIN ST DRIVEWAY DRIVEWAY DRIVEWAY DRIVEWAY S TILLICUM ST EOP EOP EOP EOP O OO OO O OO O OO OO O OO O OO OO EOPEOPEOPCEDAR RIVER 229'40'SIDEWALKSIDEWALKSIDEWALKS R I V E R S I D E D R "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN6 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. EXISTING VAULT. EXISTING VAULT. MATCH-LINE-SHEET-6 MATCH-LINE-SHEET-5 MATCH-LINE-SHEET-7 MATCH-LINE-SHEET-6 EXISTING VAULT. MFP19006530 POLE-1 POLE-2ROWROW ROWROWR O W R OWEOPEOPEOPEOP ONE WAYONE WAYONE WAYONE WAYWILLIAMS AVE SWILLIAMS AVE SWILLIAMS AVE SEOPEOPEO P EO P O O OO O OO O O O OO O OO OO O OO O OO OO O OO O OO OO O OO O OO OO O OO O OO EOPCEDAR RIVER CEDAR RIVER 166'145'O OO OO OO OO OO OOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOSIDEWALKN R I V E R S I D E D R "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN7 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 PROOF/PULL 288CT FIBER THRU EXISTING CONDUIT. RISER UP. MATCH-LINE-SHEET-7 MATCH-LINE-SHEET-6 MATCH-LINE-SHEET-8 MATCH-LINE-SHEET-7 OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 POLE-4 ROW R OW ROWROWROWROWROWROW ROWROWROWROWROWROWROWROWEOPEOPEOPEOPEOPEOPEOPEOPEO PONE WAYONE WAYONE WAYWILLIAMS AVE SN 2ND ST N 2ND ST N 1 S T S T N 1 S T S T N 1 S T S TEOPE O P E O P EOPEOP168'1 2 8 ' EOP EOP EOPEOP EOP EOP CROSS OVER POLE-3 "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN8 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MAT C H - L I N E - S H E E T - 8 MAT C H - L I N E - S H E E T - 7 MATCH-LINE-SHEET-8 MATCH-LINE-SHEET-9 OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 POLE-4 POLE-6 POLE-5 POLE-7 POLE-8 R O W ROWR OW R OW R OW ROWROW ROWROWROW ROWROWEOPEOPEOPE O P EOPEOPEOPEOPEOPEOPEOPEOPEOP EOP N 1 S T S T N 1 S T S T N 1 S T S T N 2ND ST EOPEOPEOPEOPEOPEOPEOPWELLS AVE NONE WAYONE WAYONE WAY1 6 2 ' 1 3 3 '150'125' SIDEWALK SIDEWALKSIDEWALK"DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN9 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-8 MATCH-LINE-SHEET-9MATCH-LINE-SHEET-9MATCH-LINE-SHEET-10OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 POLE-9 POLE-11 POLE-10 ROW ROW ROWROW ROW ROW ROWROW ROWROWROWROW ROWROW ROWROW EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP EOP EOP EOP EOP EOPEOPEOPEOPEOPN 2ND ST N 2ND ST N 2ND ST PARK AVE NPARK AVE N140'174'168' SIDEWALK SIDEWALK SIDEWALK "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN10 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-9MATCH-LINE-SHEET-10OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND.MATCH-LINE-SHEET-10MATCH-LINE-SHEET-11OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 POLE-12 POLE-13 POLE-14 POLE-15 ROWROW ROWROW ROWROW ROWROWROW ROW ROW EOP EOP EOP EOP EOPEOPEOPEOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPDRIVEWAY N 2ND ST N 2ND ST N 2ND ST EOPEOPGARDEN AVE NGARDEN AVE N99'105' 170'88'SIDEWALKSIDEWALK "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN11 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-10MATCH-LINE-SHEET-11OVERLASH 288CT FIBER TO EXISTING STRAND.MATCH-LINE-SHEET-11MATCH-LINE-SHEET-12OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 POLE-16 POLE-17 POLE-18 ROW ROWROWROWROWROW ROWROW ROWROWROW ROWROWROWROWROW ROWROW ROWROW ROW EOP EOP EOP EOP EOP EOPEOPEOPEOPEOP N 2ND ST N 2ND ST N 2ND ST N 2ND STMEADOW AVE NMEADOW AVE NEOPEOPEOPEOPEOPEOPEOP EOP EOP 125'107'136'"DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN12 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-11MATCH-LINE-SHEET-12OVERLASH 288CT FIBER TO EXISTING STRAND. MATCH-LINE-SHEET-13 MATCH-LINE-SHEET-12 OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 POLE-19 POLE-20 POLE-21 ROW ROWROWROWEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPMEADOW AVE NMEADOW AVE N85'111'122'"DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN13 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-14 MATCH-LINE-SHEET-13 MATCH-LINE-SHEET-13 MATCH-LINE-SHEET-12 OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 POLE-22 POLE-23 POLE-24 ROW ROWROWROW ROWROWROWROWROW EOPEOPEOPEOPEOPEOPEOPROW ROW MEADOW AVE NMEADOW AVE NONE WAYONE WAY ONE WAY ONE WAY N 3RD ST N 3RD ST N 3RD ST N 3RD STEOPEOPEOPEOPEOPEOP EOP EOP EOP EOP EOP EOP 37'140'122'"DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN14 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-14 MATCH-LINE-SHEET-13 MATCH-LINE-SHEET-13 MATCH-LINE-SHEET-12 OVERLASH 288CT FIBER TO EXISTING STRAND. PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. RISER DN. RISER UP. MFP19006530 POLE-25 POLE-26 POLE-27 ROWROWEOPEOPEOPEOPEOPEOPEOPEOPEOP EOPMEADOW AVE NMEADOW AVE N82'119'120'"DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN15 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-16 MATCH-LINE-SHEET-15 MATCH-LINE-SHEET-15 MATCH-LINE-SHEET-14 OVERLASH 288CT FIBER TO EXISTING STRAND. PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. MFP19006530 POLE-28 ROW ROW ROW ROW ROWROWROWROWEOPEOP EOP EOP EOP EOP EOP EOPEOPEOP EOP EOP EOP EOP EOP EOP MEADOW AVE NN 4TH ST N 4TH ST N 4TH ST N 4TH STONE WAY ONE WAY ONE WAY ONE WAY 83'35'277' SIDEWALK "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN16 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-16MATCH-LINE-SHEET-17MATCH-LINE-SHEET-16 MATCH-LINE-SHEET-15 OVERLASH 288CT FIBER TO EXISTING STRAND. PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER.RISER DN. PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. MFP19006530 P ROWROWROWROWROWEOP EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPFACTOR Y P L N N 4TH ST N 4TH ST FAC TOR Y P L NFACTORY AVE NON E W A Y ONE W A Y ONE WAY 165' 275' X X X X X GATE SIDEWALK SIDEWALK SIDEWALK "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN17 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-17MATCH-LINE-SHEET-18MATCH-LINE-SHEET-16MATCH-LINE-SHEET-17PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER.PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. EXISTING VAULT.EXISTING PEDESTAL VAULT. MFP19006530 P ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWEOPEOPEOPEOPEOP EOP EOP EOP EOPN 4TH ST N 4TH ST HOUSER WAY NHOUSER WAY NONE WAYONE WAYONE WAYONE WAYMH 234'234' "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN18 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-18MATCH-LINE-SHEET-19MATCH-LINE-SHEET-17MATCH-LINE-SHEET-18PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. EXISTING MANHOLE. EXISTING PEDESTAL VAULT. MFP19006530 ROWRO W ROWROWROWROWROWROW ROWEOPEOPEOP EOPEOPEOPSUNSET BLVD NSUNSET BLVD NSUNSET BLVD N318'258'FLFLFLFLFLFLFLFLFL405 405 "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN19 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-20 MATCH-LINE-SHEET-19 MATCH-LINE-SHEET-18MATCH-LINE-SHEET-19PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. EXISTING VAULT. MFP19006530 PROWROWROW ROWROWRO WROWROWEOPEOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPSUNSET BLVD NSUNSET BLVD NSUNSET BLVD NHOUSER WAY BYPHOUSER WAY BYP175'264'30'FLFLFLFLFLFLFLFLFLFLFL405 405 "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN20 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-20 MATCH-LINE-SHEET-19 MATCH-LINE-SHEET-21 MATCH-LINE-SHEET-20 PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. EXISTING VAULT. EXISTING VAULT. EXISTING PEDESTAL VAULT. MFP19006530 ROW ROW R OW ROWROWEOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOP EOPEOP EOPEOPEOPEOPEOPEOPEOPSUNSET BLVD NESUNSET BL V D NE HOUSER WAY BYP 405 OVERPASS NOT SHOWN FOR CLARITY 122' 405 OVERPASS NOT SHOWN FOR CLARITY FLFL405 "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN21 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-21 MATCH-LINE-SHEET-20 MATCH-LINE-SHEET-21MATCH-LINE-SHEET-20PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. EXISTING VAULT. PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. MFP19006530 POLE-29 POLE-30 POLE-31 ROW ROW ROWROWROWROW ROW EOP EOP EOP EOP EOP EOPEOP EOPEOPEOPSUNSE T B L V D N E 405 OVERPASS NOT SHOWN FOR CLARITY 173' 66' 182' SUNSET B L V D N E SUNSE T B L V D N E SUNSE T B L V D N E 405 EOP EOP EOP EOP GRAND E Y W A Y N E 509 SIDEW A L K SIDEW A L K "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN22 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-21MATCH-LINE-SHEET-22MATCH-L INE -SHEET -23MATCH-L INE -SHEET -22 PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. EXISTING VAULT. RISER UP. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 POLE-32 POLE-33 POLE-34ROWROW ROWROWROWROWROWROWROW ROWROW ROWROWROW EOPEOPEOPEOPEOP E O P EOPEOPEOPEOPEOPEOPEOPEOPEOP108'64'64'198'SUNS E T BL V D N E SUNSET BLVD NESUNSET BLVD NE405 HWY 405 ON RAMPHWY 405 ON RAMPBRONSON WAY NE "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN23 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-23 MATCH-LINE-SHEET-22 MATCH-LINE-SHEET-24 MATCH-LINE-SHEET-23 OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 POLE-35 POLE-36 POLE-37ROW ROWROWROWROWROWROWROWROW ROWROWROW ROWROWROW ROWROW ROWROWROWROWROWROWROW ROWROWROWROWROWROWROWEOP EOPEOPEOPEOP127'127'SUNSET BLVD NESUNSET BLVD NEEOPEOPEOPEOP"DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN24 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-24 MATCH-LINE-SHEET-23 MATCH-LINE-SHEET-25 MATCH-LINE-SHEET-24 OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 POLE-38 ROWROWROWROWROWROWROWROWROWROW ROWROWROW ROWROW ROWROWROWEOPEOPEOP233'209'SUNSET BLVD NESUNSET BLVD NEEOPEOPEOPEOPEOPEOPNE 6TH "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN25 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-25 MATCH-LINE-SHEET-24 MATCH-LINE-SHEET-26 MATCH-LINE-SHEET-25 OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 POLE-39 POLE-40 ROWROWROW ROW ROWROWROWROW ROW ROW ROWROWROW ROWROWROWROW ROW ROWROW ROW ROWROWROW ROWEOPEOPEOPEOPFLSUNSET BLVD NE SUN SET B LVD N E EOPEOPEOPEOP177' "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN26 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-26 MATCH-LINE-SHEET-25 MATCH-LINE-SHEET-27 MATCH-LINE-SHEET-26 OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND.177' MFP19006530 POLE-41 POLE-42 ROWROWROWROWROWROWROWROW ROW ROW ROWROWROWROW ROW ROW ROWROWROW ROW ROW ROWROW ROW ROWROWROWROWROWROWROWROW ROWROW ROW ROW ROWROW ROWROWEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLSUNSET BLVD NESUNSET BLVD NE153'139'142'"DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN27 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-27 MATCH-LINE-SHEET-26 MATCH-LINE-SHEET-28 MATCH-LINE-SHEET-27 OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 POLE-43 POLE-44 POLE-45ROWROWROWROWROW ROW ROW ROWROWROW EOPEOPEOP EOP EOPEOPEOPEOPEOPFLFLFLFLFLFLFLFLFLFLSUNSET BLVD NESUNSET BLVD NENE 7TH ST NE 7TH ST 103'39'144' 178'ROWCROSS OVER "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN28 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-28 MATCH-LINE-SHEET-27 MATCH-LINE-SHEET-28MATCH-LINE-SHEET-29OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 POLE-46 POLE-47 POLE-48 POLE-49ROWROWROWROWROWROWROWROW ROWROWROWROWROWROWROWROWROWROW ROWROW ROWROWROW ROWROWROWROWROWROWROWROWROWROWROWROWROW ROWEOPEOPEOPEOP EOPEOPEOPEOPEOPEOPEOPEOPEOPNE 7TH STABERDEAN AVE NENE 6TH PLNE 7TH ST EOPEOP"DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN29 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019MATCH-LINE-SHEET-28MATCH-LINE-SHEET-29MATCH-LINE-SHEET-29MATCH-LINE-SHEET-30OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 170' 110' 113' POLE-50 POLE-51 POLE-52 POLE-53 ROW ROWROWROWROWROW ROWROWROWROW ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWEOP EOPEOPEOPEOPEOPEOPEOPEOPEOP NE 7TH S T NE 7T H S TEOPEOPCAMAS AVE NE"DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN30 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019MATCH-LINE-SHEET-29MATCH-LINE-SHEET-30MATCH-LINE-SHEET-30MATCH-LINE-SHEET-31OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 148' 138' 114' 112' POLE-53 POLE-54 POLE-55 POLE-56ROWROWROWROWROWROWROWROWROWROWROWROWROW ROWROWROW ROWROWROWROWROWROWROW ROWROWROWROWEOP EOP EOP EOP EOP EOP EOPEOPEOP EOPEOPEOPNE 7T H S T NE 7 T H S T NE 7T H S TEOPEOPEOPDAYTON AVE NEEDMONDS AVE NEEDMONDS AVE NEDAYTON AVE NEEOPEOP"DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN31 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019MATCH-LINE-SHEET-30MATCH-LINE-SHEET-31MATCH-LINE-SHEET-31MATCH-LINE-SHEET-32OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 168' 155' 150' POLE-57 POLE-58 POLE-59 ROW ROW ROW ROW ROW ROWROW ROWROWROWROW ROWROWROWROW ROW ROW ROWROWROW ROWROWROWROWEOP EOP EOP EOP EOP EOP EOP EOP EOP NE 7TH ST NE 7T H S T NE 7T H S TEOPEOPEOP FERNDALE CT NE"DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN32 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019MATCH-LINE-SHEET-31MATCH-LINE-SHEET-32MATCH-LINE-SHEET-32MATCH-LINE-SHEET-33OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 177' 171' 138' POLE-60 POLE-61 POLE-62ROWROWROWROWROW RO W ROWROWROWROWROWROWROWROWROWEOP EOP EOP EOP EOP EOP EOP EOP EOP EOP NE 7TH S T NE 7TH ST HARRINGTON AVE NEHARRINGTON AVE NE"DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN33 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-32MATCH-LINE-SHEET-33MATCH-LINE-SHEET-33MATCH-LINE-SHEET-34OVERLASH 288CT FIBER TO EXISTING STRAND.OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 208' 177' 57 POLE-63 POLE-64 ROW ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROW ROW EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP NE 7TH ST NE 7TH ST NE 7TH ST INDEX PL NEINDEX PL NE"DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN34 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019MATCH-LINE-SHEET-33MATCH-LINE-SHEET-34MATCH-LINE-SHEET-34MATCH-LINE-SHEET-35OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 183 185 POLE-65 POLE-66 POLE-67 ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROW ROW ROWROWROWROWROWROWROW ROWRO W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP NE 7TH ST NE 7TH S T NE 7T H S T "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN35 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019MATCH-LINE-SHEET-34MATCH-LINE-SHEET-35MATCH- L IN E - SH E ET - 3 6MATCH- L IN E - SH E ET - 35 OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 170' 130 158 213 POLE-68 POLE-69 POLE-70 POLE-71 ROWROWROWROWROWROWROWROWROWROWROWEOP EOPEOPEOPEOPEOPEOPEOPEOPEOP EOPEOPEOPEOPNE 7T H S T NE 7TH S T ROWROWDRIVEWAYDRIVEWAYDRIVEWAY DRIVEWAY "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN36 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019MATCH-LINE-SHEET-35MATCH-LINE-SHEET-36MATCH-LINE-SHEET-37MATCH-LINE-SHEET-36OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 161 115 129 POLE-72 POLE-73 POLE-74 ROWROWROWROWROWROWROWEOPEOPEOPEOPEOPEOPEOPEOP EOPEOPEOP EOP EOP NE 7TH S T NE 7 T H S T MONROE AVE NEMONROE AVE NENE 7TH ST NE 7TH STROW ROWROWROWDRIVEWAY PARKING LOT SIDE W A L K "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN37 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-37 MATCH-LINE-SHEET-38MATCH-LINE-SHEET-37MATCH-LINE-SHEET-36OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 130 145 160 POLE-75 POLE-76ROW ROWROWROWROW ROWROWROWEOPEOPEOPEOPEOPEOPEOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPMONROE AVE NENE 7TH PL NE 7TH PLROWROWROWROWROWDRIVEWAY "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN38 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-38 MATCH-LINE-SHEET-39 MATCH-LINE-SHEET-37 MATCH-LINE-SHEET-38 OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 205 212 POLE-77 POLE-78 ROWROWROWEOPEOPEOPEOPEOP EOP EOP EOPEOPEOPEOPMONROE AVE NEMONROE AVE NEROWROWROWROWROWNE 6TH PL NE 6TH PL "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN39 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-39 MATCH-LINE-SHEET-40 MATCH-LINE-SHEET-38 MATCH-LINE-SHEET-39 OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. MFP19006530 154 157 POLE-79 POLE-80 PROWROWROWROWEOPEOPEOP EOPEOPEOPEOPEOPEOPEOPMONROE AVE NEMONROE AVE NEROWROWROWROWROWNE 6TH ST NE 6TH ST DRIVEWAY DRIVEWAY "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN40 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-40 MATCH-LINE-SHEET-41 MATCH-LINE-SHEET-39 MATCH-LINE-SHEET-40 OVERLASH 288CT FIBER TO EXISTING STRAND. OVERLASH 288CT FIBER TO EXISTING STRAND. RISER DN. EXISTING VAULT. PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. MFP19006530 198 91 PPROWROWROWEOPEOPEOPEOPEOPEOPMONROE AVE NEMONROE AVE NEROWROWROWROWDRIVEWAY DRIVEWAY DRIVEWAY "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN41 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-41 MATCH-LINE-SHEET-42 MATCH-LINE-SHEET-40 MATCH-LINE-SHEET-41 EXISTING VAULT. PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. EXISTING VAULT. PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. MFP19006530 PROWROWROWROWROWROWROWROWROWROWEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPMONROE AVE NEMONROE AVE NE189'484 SP.WAKV.0850 DRIVEWAY "DELIVERING EXCELLENCE" SEFNCO COMMUNICATIONS OF710 S 2ND STRENTON, WAJB-59934DESIGN42 42 COMCAST revisions: date:drawn by: date: checked by: * drawn by: MDB designed by: * 11/18/2019 MATCH-LINE-SHEET-41 MATCH-LINE-SHEET-42 EXISTING VAULT. PROOF/PULL THRU EXISTING CONDUIT WITH 288CT FIBER. END OF ROW DESIGN. MFP19006530 SEFNCO COMMUNICATIONS 4610 TACOMA AVE SUMNER WA, 98390 December 18, 2019 City of Renton 1055 South Grady Way Renton, WA 98057 RE: Aerial Variance Request for JB#59934 To whom it may concern, SEFNCO Communications has been contracted to design and engineer this project on behalf of Comcast Cablevision. Comcast is applying for a variance request in order to upgrade their existing facilities. Comcast proposes to overlash to existing poles, proof and place in existing conduit, build 3 new aerial spans and set new vault for storage locations. Comcast is requesting that the City of Renton approve this variance request based on the fact that the requirements for undergrounding this proposed over-lash will not cause substantial adverse impacts to other person or entities in the immediate area and will cause undue hardship. 1. Installation of undergrounding facilities will increase the total cost of construction roughly 15-25 times the amount of an aerial over-lash on the existing Comcast strand. 2. Potential damage to underground facilities will be increased. 3. Over-lash will not cause substantial adverse impact to other persons or entities in the immediate area. Over-lashing the cable will be accomplished in a few days, and the residents will not notice any impact. Comcast will clean up the over-lashed spans as necessary and identify and remove any existing dead cables along this route. 4. The variance is necessary to prevent and undue hardship due to the increased construction costs if forced to install the proposed extension underground. 5. The granting of the variance will not be materially detrimental to the public welfare because Comcast does agree to underground the cable system, but they are waiving the obligation into the future when all other utilities are underground to prevent an undue hardship against Comcast currently. Upon the granting of the Variance, Comcast will coordinate construction and traffic control as per your requirements. Comcast and their contractors want to cooperate at the highest level and agree to adhere to all provisions and requirements set forth by the City of Renton to insure safe installation and maintenance of the proposed facilities. MFP19006530 If you have any further questions regarding this project please contact Justin Withrow at 253 203-9066. Thank you for your consideration in this matter. Ashley Kiehn Permit Area Manager SEFNCO Communications, Inc. o 253 999-2271 | e askiehn@sefnco.com Attachments: 1. Application for ROW permit 2. 11” x 17” Site plan 3. 11” x 17” Design plan 4. Traffic Control Plan October 23, 2020 Ashley Kiehn SEFNCO Communications, INC. 4610 Tacoma Ave Sumner, WA 98390 Via Email: AsKiehn@sefnco.com SUBJECT: Request for Undergrounding Exemption (JB#59934, MFP19006530, 710 S 2nd St) Dear Ms. Kiehn: The City of Renton has reviewed your request to grant Comcast an exemption from Renton Municipal Code (RMC) 4-6-090(C) which states that all new electrical or communication facilities shall be required to be installed underground, pursuant to the standards of the section of RMC. Comcast proposes to have SEFNCO Communications, Inc. overlash 288ct fiber approximately 11,720 lineal feet to existing Puget Sound Energy (PSE) poles in two routes within the City: Overlash Route 1:  Beginning at the pole on the west side of Williams Ave S at the intersection of N Riverside Dr,  North crossing to the east side of Williams Avenue for 313 lineal feet,  Southeast along north side o N 1st St for 423 lineal feet,  North along west side of Wells Ave N for 150 lineal feet,  East along north side of N 2nd St for 1,301 lineal feet,  North along west side of Meadow Ave N for 1,017 lineal feet, and  Ending at the pole to the east of 359 Meadow Ave N. Overlash Route 2:  Beginning at pole located on the north side of 469 Grandey Way NE property along south side of Sunset Blvd NE,  North along Sunset Blvd NE following the meandering aerial path for 2,526 lineal feet,  East along south side NE 7th St for 4,347 lineal feet,  South along east side of Monroe Ave NE for 1,177 lineal feet, and  Ending at the pole to the northwest corner of 3303 NE 6th St. Comcast Job JB#59934 Page 2 of 3 October 23, 2020 ANALYSIS: The City has considered the request for an exemption from RMC 4-6-090. Ordinance 5720 grants Comcast, the right to install fiber optic cable and related appurtenances under, along, over, below, through and across the streets, avenues and alleys of City of Renton within the right-of-way of Renton. Section 3.4 of the franchise ordinance states that if all of the distribution lines all the wireline service providers, such as telecommunications service providers, as defined in RCW 35.99.010, a utility service provider or a Cable Operator (collectively “Service Providers”) in any portion of the Franchise Area are underground, Grantee shall place its Cable System’s distribution cables underground within that area; provided that such underground locations are actually capable of accommodating Grantee’s cable and other equipment without technical degradation of the Cable Systems’ signal quality. The proposal would utilize existing poles with other attached franchisee communication facilities and overlash to the existing Comcast aerial path. As minimum vertical height clearance of 15’-6” would need to be provided for, any existing obsolete cable will need to be removed; staff recommends these as conditions of approval. Therefore, the City is granting an exemption with conditions, per the Comcast franchise agreement which allows new overhead facilities to be placed overhead provided there are other similar providers overhead as well. DECISION: The requested exemption from underground utility installation requirements (RMC4-6-090 (C) as requested by the applicant is approved with conditions subject to the conditions below as the request complies with the Comcast Franchise Agreement. Conditions of Approval: 1. Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15’-6”. 2. Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. 3. A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 4. The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at Comcast’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case Comcast shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City of Renton Community and Economic Development Administrator or designee, from the first event triggering the requirement to underground the aerial lines. This decision to approve the exemption with conditions is subject to a fourteen (14) day appeal period from the date of this letter per RMC 4-8-110. Any appeals of the administrative decision must be filed with the City Clerk, along with the required appeal fee, by 5:00 pm, November 6, 2020. Due to Governor Jay Inslee’s Proclamation 20-25 (“Stay Home, Stay Healthy”), the City Clerk’s Office is working remotely. For that reason, appeals must be submitted electronically to the City Clerk at cityclerk@rentonwa.gov. Comcast Job JB#59934 Page 3 of 3 October 23, 2020 The appeal fee, normally due at the time an appeal is submitted, will be collected at a future date. Appeals to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov. If the situation changes such that the City Clerk’s Office is open when you file your appeal, you have the option of filing the appeal in person. Sincerely, Brianne Bannwarth, PE Development Engineering Manager cc: C.E. “Chip” Vincent, CED Administrator Vanessa Dolbee, Planning Director Justin Johnson, Assistant Development Engineering Manager Scott Warlick, Engineering Specialist III Holly Powers, Permit Technician Franchise Permits Rhonda Resnik, Comcast Rhonda_Resnik@comcast.com DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Conditions for Permit MFP19006530 Engineering 1 Engineering General Conditions A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 2 Engineering General Conditions Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. 3 Engineering General Conditions Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15’-6”. 4 Engineering General Conditions The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at Comcast’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case Comcast shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City of Renton Community and Economic Development Administrator or designee, from the first event triggering the requirement to underground the aerial lines. Page 1 of 1