Loading...
HomeMy WebLinkAboutMFP20004566.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP20004566 IVR Number: 20004566 Permit Information Permit Name: Puget Sound Energy - Electric Address/Location:10/06/2020Application Date:7227801235Parcel Number: 2832 SUNSET LN NE Permit Type:10/26/2020Issue Date:Franchise Permit Work Class:10/26/2021Expiration Date:Major Utility Job Number: 108121843Franchise Type:Electric Description: Puget Sound Energy Electric Potelco crew to wreck out P01, P02, P03, P04, P05, P06, P07, P09, P10 and wreck out existing services for new development. Install a new down guy at P08. Restoration per City of Renton standards. Contacts Name Address PhoneTypeBilling Corrie Rydberg Puget Sound Energy 6905 S 228TH St KENT, WA 98032 C: (253) 905-5031ApplicantX Carli Bunkelman PSE/POTELCO - Billing 6905 S 228th St Kent, WA 98032 B: (253) 437-6708Contractor Business License Number: 5109Construction Contractor: POTELI*227PL JSH PROPERTIES INC 923 POWELL AVE SW STE 101 RENTON , WA 98057 Owner General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF PUBLIC WORKS Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 1 of 2 | Published: 1ϭ/Ϯϱ/2019 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN (TCP) APPLICATION Published: 1ϭ/Ϯϱ/2019 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. TO THE APPLICANT: Submit the TCP application form and required submittal documents to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address. The following items, electronic copies preferred, are all required for submittal of the TCP Application: 1.܆ A copy of the Traffic Control Plan (TCP) Application form. 2.܆ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall: ܆ Include map(s) showing the location of the project and work area. ܆ Be legible lettering and clear, contrasting, symbols of viewing or printing. ܆ Must indicate street names, and north arrow and scale. ܆ All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. ܆ Types of plans required: ܆ Work hour plan – show all mobility impacts during construction hours. ܆ Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. ܆ Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. ܆ Pedestrian access/detour plan, if applicable. Project Name: ______________________________________________ Permit #: _____________________ Project Address: ____________________________________________________________________________ Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Description of Work, Work Schedule, Equipment Used: _____________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ Construction Company: ________________________________________ Phone/Cell: (_____) _____-________ Applicant Name: _________________________________ Email: ______________________________________ Business Address: _________________________________ City/State: __________________ Zip: __________ Approved By: _______________________________________________ Date: ________________________ Transportation Operations Engineering MFP20004566 Scott Warlick CED 10/26/2020 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 2 | Published: 1ϭ/Ϯϱ/2019 APPLICANT AGREES TO ALL THE FOLLOWING: x TCP must be approved prior to commencing the work, and all permit conditions shall be met. x Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. x Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. x The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of traffic. This includes set up within the traveled way or immediately adjacent to the roadway. x Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures. x Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure. x TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT) and all traffic regulations of the City of Renton and Revised Code of Washington (RCW). x Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State and City codes. x Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Applicant’s agents and employees. x The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. x In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay for legal counsel chosen by the City to defend against same. x Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. x Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. x Approved Temporary TCP must be at the work site during work hours. x Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. x Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: x Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. x Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. x The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site. x Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street; 425-430-7423). _______________________________ _______________________________ _______________________ Applicant’s Signature Print Name Date 2832 NE Sunset Blvd Renton WA 98056 USA 12 12 12 12 12 1818111110 10 1212121212NE SUNSET BLVDN E 1 0 T H S T 121212 12 BUSSTOPSUNSET LN NEN E 1 0 T H S T SUNSET LN NEP01 H01 M05 STOP FLAGGER STOP FLAGGERW20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100 ' 10 0 ' 10 0 'W20- 7 AROADWORKAHEADW20- 1 BEPREPAREDTOSTOPW3-4 100 ' 100' 100' PLACE SIGNS BOTH SIDES OF WORK AREA FROMTOTOW AWAY AREAPHONE 888 -9999INFRASOURCE LLC 000 0 0000 00 NO PARKINGNO-PARK FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARKP02 SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP POLE WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY PSE PUGETSOUNDENERGY JOB#108121843 2832 NE Sunset Blvd, Renton, WA 98056 10/1/2020 safaa.alneema@pse.com (425) 398-6077 SHEET 1 of 6Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. N MFP20004566 2832 NE Sunset Blvd Renton WA 98056 USA 111110 10 N E 1 0 T H S T 12 12 12 121616HARRINGTON PL NE17 17 SUNSET LN NEN E 1 0 T H S T SUNSET LN NEP03 H02 M06 M08 STOP FLAGGER STOP FLAGGER W20-7AROADWORKAHEADW2 0 - 1 W20-4ONE LANEROADAHEAD100 '100'100'ROADWORKAHEADW20-1100 'ROADWORKAHEADW20- 1 100' W20-7AW20-4ON E L A N E RO A D AH E A D100'100'PLACE SIGNS BOTH SIDES OF WORK AREA FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 00 0 00 00000 NO PARKINGNO-PAR K FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PAR K SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP POLE WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. N PSE PUGETSOUNDENERGY JOB#108121843 2832 NE Sunset Blvd, Renton, WA 98056 10/1/2020 safaa.alneema@pse.com (425) 398-6077 SHEET 2 of 6 MFP20004566 2832 NE Sunset Blvd Renton WA 98056 USA 12 12 12 121616HARRINGTON PL NE17 17 SUNSET LN NEN E 1 0 TH S T SUNSET LN NEP04 H03 STOP FLAGGER STOP FLAGGERW20-7A100'W20-7A RO A D W O R K AH E A D W20-1W20-4ON E L A N E RO A D AH E A D100'100'100'ROADWORKAHEADW 2 0 - 1 BEPREPAREDTOSTOPW 3 - 4 10 0 ' 10 0 ' PLACE SIGNS BOTH SIDES OF WORK AREA FROMTOTOW AWAY AREAPHONE 888-9999 INFRASOURCE LLC 0 00 0000000NO PARKINGNO-PAR K FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARKSIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP POLE WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. N PSE PUGETSOUNDENERGY JOB#108121843 2832 NE Sunset Blvd, Renton, WA 98056 10/1/2020 safaa.alneema@pse.com (425) 398-6077 SHEET 3 of 6 MFP20004566 2832 NE Sunset Blvd Renton WA 98056 USA 12 12 12 121616HARRINGTON PL NE17 17 SUNSET LN NEP05 M10 P07 M12 H04 STOP FLAGGER STOP FLAGGER W20-7ARO A D W O R K AH E A D W20-1W20-4ON E L A N E RO A D AHE A D100'100'100'W2 0 - 7 A 100 'ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'PLACE SIGNS BOTH SIDES OF WORK AREA FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000 NO PARKINGNO-PAR K FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PAR K P06 SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP POLE WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. N PSE PUGETSOUNDENERGY JOB#108121843 2832 NE Sunset Blvd, Renton, WA 98056 10/1/2020 safaa.alneema@pse.com (425) 398-6077 SHEET 4 of 6 MFP20004566 2832 NE Sunset Blvd Renton WA 98056 USA 12 12 12 121616HARRINGTON PL NE17 17 SUNSET LN NESUNSET LN NEP02 H02 M06 M08 P05 H04 P09 M13 P10 M14 7777 STREETCLOSEDBARRICADE R11-2R11-4R5-133ROAD CLOSEDTOTHRU TRAFFICLOCALACCESSONLYSTR E E T CL O S E D BARRICA D E R11 - 2 AL L E Y CL O S E D A H E A D ALLEY-CLOSED-AHD ALLEYCLOSEDAHEADALLEY-CLOSED-AHD 100'100'ALLEYCLOSEDAHEADALLEY-CLOSED-AHDALLEYCLOSEDAHEADALLEY-CLOSED-AHD 10 0 '100'SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. N LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW POLE WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY PSE PUGETSOUNDENERGY JOB#108121843 2832 NE Sunset Blvd, Renton, WA 98056 10/1/2020 safaa.alneema@pse.com (425) 398-6077 SHEET 5 of 6 MFP20004566 2832 NE Sunset Blvd Renton WA 98056 USA 12 121616HARRINGTON PL NE17 17 SUNSET LN NEP07 M12 H04 P08 77 STOP FLAGGER STOP FLAGGERW20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7ARO A D W O R K AH E A D W20-1W20-4ON E L A N E RO A D AH E A D100'100'100'RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE EMERGENCY VEHICLES WILL BE ALLOWED TO PASS WORK ZONE. SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 012238 Card Exp. 09/30/2023 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. N 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP POLE WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY PSE PUGETSOUNDENERGY JOB#108121843 2832 NE Sunset Blvd, Renton, WA 98056 10/1/2020 safaa.alneema@pse.com (425) 398-6077 SHEET 6 of 6 MFP20004566 1162 975 2806 1140 1100 2806 HARRINGTON PL NEHARRINGTON AVE NENE SUNSET BLVDHARRINGTON PL NESUNSET LN NEHARRINGTON AVE NENE 1 0 T H S T 318607-166743 SLAH5037 318610-166735 318620-166726 SLAH5038 318622-166725 318619-166715 100 kVA 120/240V (A) 318611-166710 75 kVA 120/240V (A) 318575-166698 300 kVA 120/208V (ABC) 318555-166694 318557-166687 318621-166701 100 kVA 120/240V (B) 318622-166681 SLAH5041 318602-166683 100 kVA 120/240V (B) PRE 11 2828 Sunset Ln NE Renton WA 98056 USA ROW 50' AØ-EHC868 BØ-EHC869 CØ-EHC870 #4 CUCB A CB A #4 CU#2 ACSR# 2 AC SR CBA #2 A C S R #2 AC S R #2 ACSRABCABC#4 ACSRC B A N 318596-166715 3 X 25kVA 120/208V (ABC) 318608-166723 3 X 37.5kVA 120/208V (ABC) SLAH5039 318616-166751 3 X 50kVA 120/208V (ABC) 318598-166743 3 X 25kVA 120/208V (ABC) 318582-166731 SLAH5036 318567-166713 3 X 100kVA 120/208V (ABC) SLAH5035 318557-166713 3 X 25kVA 120/208V (ABC) SLAH5034 318558-166709 40T T76885 J J SITE PLAN N Vicinity Map 47.501648, -122.180283 Owner / Developer Contact Info officeATTN: SOLERA MANAGER LLC 10900 NE 8TH ST, SUITE 1200 BELLEVUE, WA 98004 DALTON ARNDT (253) 606-0715 ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. GAS PHONE CABLE TV 509316763 108121843 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior Service Removal Relocation Removal Temporary Job Order Distribution HP Svc/MSA POWER GENERAL NOTES - COMMERCIAL PROJECT 8. EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. Roads shall be paved or have a compacted , crushed rock base in place. CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them. All work is to be done in accordance with local municipal and county permit requirements as applicable. Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits and crossings from the individual unit's meter base to the designated connection point. Inclement weather conditions may cause delays in construction times and dates. 1. 2. 3. 4. 5. 6. 7. 9. 11. 10. PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" E-Mail: Cell Phone: Project Manager Contact Information: Manager:Dave Honeysett 253-245-0883 Dave.Honeysett@pse.com SCALE: 1" = 50'108121843THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Dave Honeysett 253-245-0883 9/21/20 Jessica Reibman 425-457-4004 9/21/20 N/A N/A N/A Jessica Reibman 425-457-4004 9/21/20 RW#RENTON SOLERA - SERVIC WRECK OUT POLES REMOVAL, REMOVE OH SVCS & METERS 2832 SUNSET LN NE, RENTON, WA 98056 N/A N/A N/A 108121843 AS NOTED 1/2 KING N/A N/A CSPSKEPM NW 9-23N-05E N/A N/A 2305E034 2305E040 2305E034 PRE-11 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Service Stubs 108122688 N/A N/A 509316797 N/A 00 1"2" 00 50'100' SITE SPECIFIC NOTES J01 EXISTING (318557-166687) -EXISTING VAULT TO REMAIN -PARK CABLES AØ-EHC868, BØ-EHC869, CØ-EHC870 P01 REMOVE (318558-166709) -POTELCO TO TOP EXISTING 2017 45' CL-3 DISTRIBUTION POLE AT COMM. LEVEL -COMMUNICATION TO REMOVE EQUIPMENT -POTELCO TO REMOVE POLE STUB AFTER COMM. HAS TRANSFERRED P02 REMOVE (318557-166713) -POTELCO TO TOP EXISTING 1958 40' CL-2 DISTRIBUTION POLE AT COMM. LEVEL -DISCONNECT OH SVC & OH TO UG SECONDARY SVC CABLE FROM POLE -REMOVE EXISTING OH TRF & RETURN TO PSE YARD -REMOVE EXISTING POLE MOUNTED LUMINARIES & RETURN TO PSE YARD -COMMUNICATION TO REMOVE EQUIPMENT -POTELCO TO REMOVE POLE STUB AFTER COMM. HAS TRANSFERRED P03 REMOVE (318567-166713) -POTELCO TO TOP EXISTING 1958 40' CL-2 DISTRIBUTION POLE AT COMM. LEVEL -DISCONNECT OH SVC & OH TO UG SECONDARY SVC CABLE FROM POLE -REMOVE EXISTING OH TRF & RETURN TO PSE YARD -REMOVE EXISTING POLE MOUNTED LUMINARIES & RETURN TO PSE YARD -COMMUNICATION TO REMOVE EQUIPMENT -POTELCO TO REMOVE POLE STUB AFTER COMM. HAS TRANSFERRED P04 REMOVE (318582-166731) -POTELCO TO TOP EXISTING 1958 40' CL-3 DISTRIBUTION POLE AT COMM. LEVEL -DISCONNECT OH TO UG SECONDARY SVC CABLE FROM POLE -REMOVE EXISTING POLE MOUNTED LUMINARIES & RETURN TO PSE YARD -COMMUNICATION TO REMOVE EQUIPMENT -POTELCO TO REMOVE POLE STUB AFTER COMM. HAS TRANSFERRED P05 REMOVE (318598-166743) -POTELCO TO TOP EXISTING 1961 45' CL-4 DISTRIBUTION POLE AT COMM. LEVEL -DISCONNECT OH SVC FROM POLE -REMOVE EXISTING OH TRF BANK & RETURN TO PSE YARD -COMMUNICATION TO REMOVE EQUIPMENT -POTELCO TO REMOVE POLE STUB AFTER COMM. HAS TRANSFERRED P06 REMOVE (318607-166743) -POTELCO TO TOP EXISTING 1960 45' CL-3 DISTRIBUTION POLE AT COMM. LEVEL -DISCONNECT OH SEC AT POLE -COMMUNICATION TO REMOVE EQUIPMENT -POTELCO TO REMOVE POLE STUB AFTER COMM. HAS TRANSFERRED P07 REMOVE (318616-166751) -POTELCO TO TOP EXISTING 1961 45' CL-2 DISTRIBUTION POLE AT COMM. LEVEL -DISCONNECT OH SVCS FROM POLE -REMOVE EXISTING OH TRF & RETURN TO PSE YARD -COMMUNICATION TO REMOVE EQUIPMENT -POTELCO TO REMOVE POLE STUB AFTER COMM. HAS TRANSFERRED P08 EXISTING (318610-166735) -EXISTING 1964 45' CL-1 DISTRIBUTION POLE TO REMAIN -INSTALL DOWN GUY P09 REMOVE (318608-166723) -POTELCO TO TOP EXISTING 1965 45' CL-4 DISTRIBUTION POLE AT COMM. LEVEL -REMOVE EXISTING OH TRF & RETURN TO PSE YARD -DISCONNECT OH SVC FROM POLE -COMMUNICATION TO REMOVE EQUIPMENT -POTELCO TO REMOVE POLE STUB AFTER COMM. HAS TRANSFERRED P10 REMOVE (318596-166715) -POTELCO TO TOP EXISTING 1965 40' CL-1 DISTRIBUTION POLE AT COMM. LEVEL -REMOVE EXISTING OH TRF & RETURN TO PSE YARD -DISCONNECT OH SVC FROM POLE -COMMUNICATION TO REMOVE EQUIPMENT -POTELCO TO REMOVE POLE STUB AFTER COMM. HAS TRANSFERRED H01 EXISTING -ABANDON EXISTING HAND HOLE AND EQUIPMENT H02 EXISTING -ABANDON EXISTING HAND HOLE AND EQUIPMENT H03 EXISTING -ABANDON EXISTING HAND HOLE AND EQUIPMENT H04 EXISTING -ABANDON EXISTING HAND HOLE AND EQUIPMENT M01 THROUGH M14 -PSE TO REMOVE METERS SEE LIST BELOW SPAN NOTES P02 TO H01 -REMOVE OH TO UG SEC, ± 50', ACTUAL____' P02 TO M05 -REMOVE OH SVC, ± 105', ACTUAL____' P03 TO H02 -REMOVED OH TO UG SEC, ± 50', ACTUAL____' P03 TO M06 -REMOVE OH SVC, ± 40', ACTUAL____' P03 TO M08 -REMOVE OH SVC, ± 100', ACTUAL____' P04 TO H03 -REMOVE OH TO UG SEC, ± 150', ACTUAL____' METER #ADDRESS NOT#3000# Z009442117 2832 SUNSET LN NE 509641047 3000817771 Z017691166 2834 SUNSET LN NE 509643894 Z063583599 2834 SUNSET LN NE 509643895 Z002781033 2830 SUNSET LN NE 509643896 Z001847531 2902 NE SUNSET BLVD 509643897 3000820197 Z004555303 2848 NE SUNSET BLVD, LIGHT 509643899 P149157900 2828 SUNSET LN NE 509643940 3000819855 P152744850 2832 NE SUNSET BLVD 509643797 3000820221 P152745389 2838 NE SUNSET BLVD 509643854 P152744849 2844 NE SUNSET BLVD 509643855 P152744851 2840 NE SUNSET BLVD 509643856 P152744852 2834 NE SUNSET BLVD, OFFC 509643857 P152744817 2836 NE SUNSET BLVD 509643858 P152744818 2832 NE SUNSET BLVD 509643589 P152744819 2842 NE SUNSET BLVD 509643890 P152744820 2848 NE SUNSET BLVD, LIGHT 509643891 X144390502 2830 NE SUNSET BLVD, B 509643943 3000820114 H099364987 2830 NE SUNSET BLVD, A 509643944 Z010192007 1171 KIRKLAND AVE NE 509643945 3000820207 Z008099949 2808 NE SUNSET BLVD 509643946 3000819858 Z064422293 2808 NE SUNSET BLVD 509643948 P149157899 2812 NE SUNSET BLVD 509643949 3000820116 P149157370 2810 NE SUNSET BLVD, 1281 509643990 Z002780812 2816 NE SUNSET BLVD 509643991 P152745369 2806 NE SUNSET BLVD,B2 509643992 3000820210 P152745371 2806 NE SUNSET BLVD,C-D 509643994 P152745370 2806 NE SUNSET BLVD,E-F-G 509644241 X150928706 2806 NE SUNSET BLVD, B 509644242 X149150576 2806 NE SUNSET BLVD, A 509644245 X149150575 2806 NE SUNSET BLVD, HSE 509644247 P05 TO M10 -REMOVE OH SVC, ± 50', ACTUAL____' P06 TO H04 -REMOVE OH TO UG SEC, ± 50', ACTUAL____' P06 TO M12 -REMOVE OH SVC, ± 50', ACTUAL____' P07 TO M13 -REMOVE OH SVC, ± 30', ACTUAL____' P08 TO M14 -REMOVE OH SVC, ± 30', ACTUAL____' RESTORATION PER CITY OF RENTON STANDARDS This permit is for Major construction work in the ROW and will be billed at an additional $60/HR for inspections. After hours and weekend work will be billed at $125/HR MFP20004566 108121843UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Dave Honeysett 253-245-0883 9/21/20 Jessica Reibman 425-457-4004 9/21/20 N/A N/A N/A Jessica Reibman 425-457-4004 9/21/20 RW#RENTON SOLERA - SERVIC WRECK OUT POLES REMOVAL, REMOVE OH SVCS & METERS 2832 SUNSET LN NE, RENTON, WA 98056 N/A N/A N/A 108121843 AS NOTED 2/2 KING N/A N/A CSPSKEPM NW 9-23N-05E N/A N/A 2305E034 2305E040 2305E034 PRE-11 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A OVERHEAD CIRCUIT MAP SCALE: 6" = 1 MILE POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS SITE # POLE DATA POLE TEL TV FIBER TRAN RMVD ID NUMBER GRID #HEIGHT CLASS YEAR TOPPED RMVD P01 318558-166709 45 3 2017 P02 318557-166713 40 2 1958 P03 318567-166713 40 2 1958 P04 318582-166731 40 3 1958 P05 318598-166743 45 4 1961 P06 318607-166743 45 3 1960 P07 318616-166751 45 2 1961 P09 318608-166723 45 4 1965 P10 318596-166715 40 1 1965 WIRE REMOVAL TABLE Location Wire Size & Type Quantity Length (per conductor)RemarksFromTo P01 P02 #4 CU - PRIM/NEU XX XXX P02 P03 #4 CU - PRIM/NEU P03 P04 #2 ACSR - PRIM/NEU P04 P05 #4 CU - PRIM/NEU P05 P06 #2 ACSR - PRIM/NEU P06 P07 #4 ACSR - PRIM/NEU P07 P08 SPAN GUY P06 P08 #2 ACSR - PRIM/NEU P08 P09 #2 ACSR - PRIM/NEU P09 P10 #2 ACSR - PRIM/NEU P10 P11 SPAN GUY/OH SEC Total Feet (Wire Size & Type) Removed Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage P02 318557-166713 3 X 25kVA 120/208v Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage P03 318567-166713 3 X 100kVA 120/208v Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage P05 318598-166743 3 X 25kVA 120/208v Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage P07 318616-166751 3 X 50kVA 120/208v Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage P09 318608-166723 3 X 37.5kVA 120/208v Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage P10 318557-166713 3 X 25kVA 120/208V JOB SITE MFP20004566 MFP20004566