HomeMy WebLinkAboutMFP20004566.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Major Franchise Permit: MFP20004566
IVR Number: 20004566
Permit Information
Permit Name: Puget Sound Energy - Electric
Address/Location:10/06/2020Application Date:7227801235Parcel Number: 2832 SUNSET LN NE
Permit Type:10/26/2020Issue Date:Franchise
Permit Work Class:10/26/2021Expiration Date:Major Utility
Job Number: 108121843Franchise Type:Electric
Description: Puget Sound Energy Electric Potelco crew to wreck out P01, P02, P03, P04, P05, P06, P07, P09, P10 and wreck out
existing services for new development. Install a new down guy at P08. Restoration per City of Renton standards.
Contacts
Name Address PhoneTypeBilling
Corrie Rydberg
Puget Sound Energy
6905 S 228TH St
KENT, WA 98032
C: (253) 905-5031ApplicantX
Carli Bunkelman
PSE/POTELCO - Billing
6905 S 228th St
Kent, WA 98032
B: (253) 437-6708Contractor
Business License Number: 5109Construction Contractor: POTELI*227PL
JSH PROPERTIES INC 923 POWELL AVE SW STE 101
RENTON , WA 98057
Owner
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF PUBLIC WORKS
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 1 of 2 | Published: 1ϭ/Ϯϱ/2019
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN (TCP) APPLICATION
Published: 1ϭ/Ϯϱ/2019
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and
obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
TO THE APPLICANT: Submit the TCP application form and required submittal documents to
TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address.
The following items, electronic copies preferred, are all required for submittal of the TCP Application:
1.܆ A copy of the Traffic Control Plan (TCP) Application form.
2.܆ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall:
܆ Include map(s) showing the location of the project and work area.
܆ Be legible lettering and clear, contrasting, symbols of viewing or printing.
܆ Must indicate street names, and north arrow and scale.
܆ All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State
Traffic Control Flagger Certification handbook, by the Evergreen Safety Council.
܆ Types of plans required:
܆ Work hour plan – show all mobility impacts during construction hours.
܆ Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
܆ Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
܆ Pedestrian access/detour plan, if applicable.
Project Name: ______________________________________________ Permit #: _____________________
Project Address: ____________________________________________________________________________
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Description of Work, Work Schedule, Equipment Used: _____________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
Construction Company: ________________________________________ Phone/Cell: (_____) _____-________
Applicant Name: _________________________________ Email: ______________________________________
Business Address: _________________________________ City/State: __________________ Zip: __________
Approved By: _______________________________________________ Date: ________________________
Transportation Operations Engineering
MFP20004566
Scott Warlick CED 10/26/2020
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 2 | Published: 1ϭ/Ϯϱ/2019
APPLICANT AGREES TO ALL THE FOLLOWING:
x TCP must be approved prior to commencing the work, and all permit conditions shall be met.
x Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner
at a time, with the least possible inconvenience or delay to pedestrians.
x Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or
slippery road conditions during work and non-work hours.
x The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of
traffic. This includes set up within the traveled way or immediately adjacent to the roadway.
x Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures.
x Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including
public transit, to be affected by a temporary lane or road closure.
x TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on
Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT)
and all traffic regulations of the City of Renton and Revised Code of Washington (RCW).
x Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or
Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State
and City codes.
x Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles
and the acts of the Applicant’s agents and employees.
x The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and
in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s
reasonable attorney’s fees and litigation costs incurred resulting from such claim.
x In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay
for legal counsel chosen by the City to defend against same.
x Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
x Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
x Approved Temporary TCP must be at the work site during work hours.
x Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
x Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
x Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations
for vacate parking or curb lane usage.
x Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
x The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site.
x Temporary traffic control devices must be removed immediately when work is done or no construction
activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance
shop (3555 NE 2nd Street; 425-430-7423).
_______________________________ _______________________________ _______________________
Applicant’s Signature Print Name Date
2832 NE Sunset Blvd
Renton
WA 98056
USA
12
12
12
12
12
1818111110
10 1212121212NE SUNSET BLVDN
E
1
0
T
H
S
T 121212
12
BUSSTOPSUNSET LN NEN
E
1
0
T
H
S
T SUNSET LN NEP01
H01
M05
STOP
FLAGGER
STOP
FLAGGERW20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100
'
10
0
'
10
0
'W20-
7
AROADWORKAHEADW20-
1 BEPREPAREDTOSTOPW3-4
100
'
100'
100'
PLACE SIGNS
BOTH SIDES OF
WORK AREA
FROMTOTOW AWAY AREAPHONE 888
-9999INFRASOURCE
LLC
000
0
0000
00 NO PARKINGNO-PARK FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARKP02
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
TEMPORARY TRAFFIC CONTROL PLAN
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
POLE
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
PSE PUGETSOUNDENERGY
JOB#108121843
2832 NE Sunset Blvd, Renton, WA 98056
10/1/2020
safaa.alneema@pse.com
(425) 398-6077
SHEET 1 of 6Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
N
MFP20004566
2832 NE Sunset Blvd
Renton
WA 98056
USA
111110
10
N
E
1
0
T
H
S
T
12
12
12
121616HARRINGTON PL NE17
17
SUNSET LN NEN
E
1
0
T
H
S
T SUNSET LN NEP03
H02
M06
M08
STOP
FLAGGER
STOP
FLAGGER W20-7AROADWORKAHEADW2
0
-
1 W20-4ONE LANEROADAHEAD100
'100'100'ROADWORKAHEADW20-1100
'ROADWORKAHEADW20-
1
100'
W20-7AW20-4ON
E
L
A
N
E
RO
A
D
AH
E
A
D100'100'PLACE SIGNS
BOTH SIDES OF
WORK AREA
FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE
LLC
00
0
00
00000 NO PARKINGNO-PAR
K FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PAR
K
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
TEMPORARY TRAFFIC CONTROL PLAN
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
POLE
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
N PSE PUGETSOUNDENERGY
JOB#108121843
2832 NE Sunset Blvd, Renton, WA 98056
10/1/2020
safaa.alneema@pse.com
(425) 398-6077
SHEET 2 of 6
MFP20004566
2832 NE Sunset Blvd
Renton
WA 98056
USA
12
12
12
121616HARRINGTON PL NE17
17
SUNSET LN NEN
E
1
0
TH
S
T SUNSET LN NEP04
H03
STOP
FLAGGER
STOP
FLAGGERW20-7A100'W20-7A
RO
A
D
W
O
R
K
AH
E
A
D
W20-1W20-4ON
E
L
A
N
E
RO
A
D
AH
E
A
D100'100'100'ROADWORKAHEADW
2
0
-
1
BEPREPAREDTOSTOPW
3
-
4
10
0
'
10
0
'
PLACE SIGNS
BOTH SIDES OF
WORK AREA
FROMTOTOW AWAY AREAPHONE 888-9999
INFRASOURCE
LLC
0
00
0000000NO PARKINGNO-PAR
K FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARKSIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
TEMPORARY TRAFFIC CONTROL PLAN
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
POLE
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
N PSE PUGETSOUNDENERGY
JOB#108121843
2832 NE Sunset Blvd, Renton, WA 98056
10/1/2020
safaa.alneema@pse.com
(425) 398-6077
SHEET 3 of 6
MFP20004566
2832 NE Sunset Blvd
Renton
WA 98056
USA
12
12
12
121616HARRINGTON PL NE17
17
SUNSET LN NEP05
M10
P07
M12
H04
STOP
FLAGGER
STOP
FLAGGER
W20-7ARO
A
D
W
O
R
K
AH
E
A
D
W20-1W20-4ON
E
L
A
N
E
RO
A
D
AHE
A
D100'100'100'W2
0
-
7
A
100
'ROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'PLACE SIGNS
BOTH SIDES OF
WORK AREA
FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC
000
0000000 NO PARKINGNO-PAR
K FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PAR
K
P06
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
TEMPORARY TRAFFIC CONTROL PLAN
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
POLE
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
N PSE PUGETSOUNDENERGY
JOB#108121843
2832 NE Sunset Blvd, Renton, WA 98056
10/1/2020
safaa.alneema@pse.com
(425) 398-6077
SHEET 4 of 6
MFP20004566
2832 NE Sunset Blvd
Renton
WA 98056
USA
12
12
12
121616HARRINGTON PL NE17
17
SUNSET LN NESUNSET LN NEP02
H02
M06
M08
P05
H04
P09
M13
P10
M14
7777 STREETCLOSEDBARRICADE
R11-2R11-4R5-133ROAD CLOSEDTOTHRU TRAFFICLOCALACCESSONLYSTR
E
E
T
CL
O
S
E
D
BARRICA
D
E
R11
-
2
AL
L
E
Y
CL
O
S
E
D
A
H
E
A
D
ALLEY-CLOSED-AHD ALLEYCLOSEDAHEADALLEY-CLOSED-AHD
100'100'ALLEYCLOSEDAHEADALLEY-CLOSED-AHDALLEYCLOSEDAHEADALLEY-CLOSED-AHD
10
0
'100'SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
TEMPORARY TRAFFIC CONTROL PLAN
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
N
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
POLE
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
PSE PUGETSOUNDENERGY
JOB#108121843
2832 NE Sunset Blvd, Renton, WA 98056
10/1/2020
safaa.alneema@pse.com
(425) 398-6077
SHEET 5 of 6
MFP20004566
2832 NE Sunset Blvd
Renton
WA 98056
USA
12
121616HARRINGTON PL NE17
17
SUNSET LN NEP07
M12
H04
P08
77
STOP
FLAGGER
STOP
FLAGGERW20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD100'100'100'W20-7ARO
A
D
W
O
R
K
AH
E
A
D
W20-1W20-4ON
E
L
A
N
E
RO
A
D
AH
E
A
D100'100'100'RESIDENT(S) WILL BE INFORMED OF
TEMPORARY DRIVEWAY CLOSURE
EMERGENCY VEHICLES WILL BE
ALLOWED TO PASS WORK ZONE.
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
TEMPORARY TRAFFIC CONTROL PLAN
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
N
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
SIGN LOCATION
FLAGGER
STOP
POLE
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
PSE PUGETSOUNDENERGY
JOB#108121843
2832 NE Sunset Blvd, Renton, WA 98056
10/1/2020
safaa.alneema@pse.com
(425) 398-6077
SHEET 6 of 6
MFP20004566
1162
975
2806
1140
1100
2806 HARRINGTON PL NEHARRINGTON AVE NENE SUNSET BLVDHARRINGTON PL NESUNSET LN NEHARRINGTON AVE NENE 1
0
T
H
S
T
318607-166743
SLAH5037
318610-166735
318620-166726
SLAH5038
318622-166725
318619-166715
100 kVA 120/240V (A)
318611-166710
75 kVA 120/240V (A)
318575-166698
300 kVA 120/208V (ABC)
318555-166694
318557-166687
318621-166701
100 kVA 120/240V (B)
318622-166681
SLAH5041
318602-166683
100 kVA 120/240V (B)
PRE
11
2828 Sunset Ln NE
Renton
WA 98056
USA
ROW
50'
AØ-EHC868
BØ-EHC869
CØ-EHC870 #4 CUCB
A
CB
A
#4 CU#2 ACSR#
2
AC
SR
CBA
#2
A
C
S
R
#2 AC
S
R
#2 ACSRABCABC#4 ACSRC
B
A
N
318596-166715
3 X 25kVA 120/208V (ABC)
318608-166723
3 X 37.5kVA 120/208V (ABC)
SLAH5039
318616-166751
3 X 50kVA 120/208V (ABC)
318598-166743
3 X 25kVA 120/208V (ABC)
318582-166731
SLAH5036
318567-166713
3 X 100kVA 120/208V (ABC)
SLAH5035
318557-166713
3 X 25kVA 120/208V (ABC)
SLAH5034
318558-166709
40T
T76885
J
J
SITE PLAN
N
Vicinity Map
47.501648, -122.180283
Owner / Developer Contact Info
officeATTN:
SOLERA MANAGER LLC
10900 NE 8TH ST, SUITE 1200
BELLEVUE, WA 98004
DALTON ARNDT (253) 606-0715
ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
EROSION & SEDIMENT CONTROL REQUIREMENTS
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
GAS
PHONE
CABLE TV
509316763 108121843
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A
N/A N/A
PROJECT PHASE
PWR
NOTIF#ORDER#
Superior
Service Removal
Relocation
Removal
Temporary
Job Order
Distribution
HP Svc/MSA
POWER GENERAL NOTES - COMMERCIAL PROJECT
8.
EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and
restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over
PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer
will provide any and all shoring or they will side slope the trench to 1:1.
All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from
this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy.
All switching arrangements and/or outage arrangements are to be made with the Project Manager at least
three (3) working days in advance.
Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing
work to get the underground facilities located.
STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk,
etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager.
SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction
materials which would restrict construction and/or equipment access, before work can begin.
Roads shall be paved or have a compacted , crushed rock base in place.
CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from
combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard
posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water,
storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them.
All work is to be done in accordance with local municipal and county permit requirements as applicable.
Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits
and crossings from the individual unit's meter base to the designated connection point.
Inclement weather conditions may cause delays in construction times and dates.
1.
2.
3.
4.
5.
6.
7.
9.
11.
10.
PSE
No
No
No
Yes
Yes
Yes
No
YesDeveloper
"Flagging Required"
"Outages Required"
"Locates Required"
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager:Dave Honeysett
253-245-0883
Dave.Honeysett@pse.com
SCALE: 1" = 50'108121843THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
Dave Honeysett 253-245-0883 9/21/20
Jessica Reibman 425-457-4004 9/21/20
N/A N/A N/A
Jessica Reibman 425-457-4004 9/21/20
RW#RENTON
SOLERA - SERVIC WRECK OUT
POLES REMOVAL, REMOVE OH SVCS & METERS
2832 SUNSET LN NE, RENTON, WA 98056
N/A N/A
N/A 108121843
AS NOTED 1/2
KING N/A N/A CSPSKEPM
NW 9-23N-05E N/A N/A
2305E034 2305E040 2305E034 PRE-11
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
Service Stubs
108122688
N/A
N/A
509316797
N/A
00 1"2"
00 50'100'
SITE SPECIFIC NOTES
J01 EXISTING (318557-166687)
-EXISTING VAULT TO REMAIN
-PARK CABLES AØ-EHC868, BØ-EHC869, CØ-EHC870
P01 REMOVE (318558-166709)
-POTELCO TO TOP EXISTING 2017 45' CL-3 DISTRIBUTION POLE AT COMM. LEVEL
-COMMUNICATION TO REMOVE EQUIPMENT
-POTELCO TO REMOVE POLE STUB AFTER COMM. HAS TRANSFERRED
P02 REMOVE (318557-166713)
-POTELCO TO TOP EXISTING 1958 40' CL-2 DISTRIBUTION POLE AT COMM. LEVEL
-DISCONNECT OH SVC & OH TO UG SECONDARY SVC CABLE FROM POLE
-REMOVE EXISTING OH TRF & RETURN TO PSE YARD
-REMOVE EXISTING POLE MOUNTED LUMINARIES & RETURN TO PSE YARD
-COMMUNICATION TO REMOVE EQUIPMENT
-POTELCO TO REMOVE POLE STUB AFTER COMM. HAS TRANSFERRED
P03 REMOVE (318567-166713)
-POTELCO TO TOP EXISTING 1958 40' CL-2 DISTRIBUTION POLE AT COMM. LEVEL
-DISCONNECT OH SVC & OH TO UG SECONDARY SVC CABLE FROM POLE
-REMOVE EXISTING OH TRF & RETURN TO PSE YARD
-REMOVE EXISTING POLE MOUNTED LUMINARIES & RETURN TO PSE YARD
-COMMUNICATION TO REMOVE EQUIPMENT
-POTELCO TO REMOVE POLE STUB AFTER COMM. HAS TRANSFERRED
P04 REMOVE (318582-166731)
-POTELCO TO TOP EXISTING 1958 40' CL-3 DISTRIBUTION POLE AT COMM. LEVEL
-DISCONNECT OH TO UG SECONDARY SVC CABLE FROM POLE
-REMOVE EXISTING POLE MOUNTED LUMINARIES & RETURN TO PSE YARD
-COMMUNICATION TO REMOVE EQUIPMENT
-POTELCO TO REMOVE POLE STUB AFTER COMM. HAS TRANSFERRED
P05 REMOVE (318598-166743)
-POTELCO TO TOP EXISTING 1961 45' CL-4 DISTRIBUTION POLE AT COMM. LEVEL
-DISCONNECT OH SVC FROM POLE
-REMOVE EXISTING OH TRF BANK & RETURN TO PSE YARD
-COMMUNICATION TO REMOVE EQUIPMENT
-POTELCO TO REMOVE POLE STUB AFTER COMM. HAS TRANSFERRED
P06 REMOVE (318607-166743)
-POTELCO TO TOP EXISTING 1960 45' CL-3 DISTRIBUTION POLE AT COMM. LEVEL
-DISCONNECT OH SEC AT POLE
-COMMUNICATION TO REMOVE EQUIPMENT
-POTELCO TO REMOVE POLE STUB AFTER COMM. HAS TRANSFERRED
P07 REMOVE (318616-166751)
-POTELCO TO TOP EXISTING 1961 45' CL-2 DISTRIBUTION POLE AT COMM. LEVEL
-DISCONNECT OH SVCS FROM POLE
-REMOVE EXISTING OH TRF & RETURN TO PSE YARD
-COMMUNICATION TO REMOVE EQUIPMENT
-POTELCO TO REMOVE POLE STUB AFTER COMM. HAS TRANSFERRED
P08 EXISTING (318610-166735)
-EXISTING 1964 45' CL-1 DISTRIBUTION POLE TO REMAIN
-INSTALL DOWN GUY
P09 REMOVE (318608-166723)
-POTELCO TO TOP EXISTING 1965 45' CL-4 DISTRIBUTION POLE AT COMM. LEVEL
-REMOVE EXISTING OH TRF & RETURN TO PSE YARD
-DISCONNECT OH SVC FROM POLE
-COMMUNICATION TO REMOVE EQUIPMENT
-POTELCO TO REMOVE POLE STUB AFTER COMM. HAS TRANSFERRED
P10 REMOVE (318596-166715)
-POTELCO TO TOP EXISTING 1965 40' CL-1 DISTRIBUTION POLE AT COMM. LEVEL
-REMOVE EXISTING OH TRF & RETURN TO PSE YARD
-DISCONNECT OH SVC FROM POLE
-COMMUNICATION TO REMOVE EQUIPMENT
-POTELCO TO REMOVE POLE STUB AFTER COMM. HAS TRANSFERRED
H01 EXISTING
-ABANDON EXISTING HAND HOLE AND EQUIPMENT
H02 EXISTING
-ABANDON EXISTING HAND HOLE AND EQUIPMENT
H03 EXISTING
-ABANDON EXISTING HAND HOLE AND EQUIPMENT
H04 EXISTING
-ABANDON EXISTING HAND HOLE AND EQUIPMENT
M01 THROUGH M14
-PSE TO REMOVE METERS SEE LIST BELOW
SPAN NOTES
P02 TO H01
-REMOVE OH TO UG SEC, ± 50', ACTUAL____'
P02 TO M05
-REMOVE OH SVC, ± 105', ACTUAL____'
P03 TO H02
-REMOVED OH TO UG SEC, ± 50', ACTUAL____'
P03 TO M06
-REMOVE OH SVC, ± 40', ACTUAL____'
P03 TO M08
-REMOVE OH SVC, ± 100', ACTUAL____'
P04 TO H03
-REMOVE OH TO UG SEC, ± 150', ACTUAL____'
METER #ADDRESS NOT#3000#
Z009442117 2832 SUNSET LN NE 509641047 3000817771
Z017691166 2834 SUNSET LN NE 509643894
Z063583599 2834 SUNSET LN NE 509643895
Z002781033 2830 SUNSET LN NE 509643896
Z001847531 2902 NE SUNSET BLVD 509643897 3000820197
Z004555303 2848 NE SUNSET BLVD, LIGHT 509643899
P149157900 2828 SUNSET LN NE 509643940 3000819855
P152744850 2832 NE SUNSET BLVD 509643797 3000820221
P152745389 2838 NE SUNSET BLVD 509643854
P152744849 2844 NE SUNSET BLVD 509643855
P152744851 2840 NE SUNSET BLVD 509643856
P152744852 2834 NE SUNSET BLVD, OFFC 509643857
P152744817 2836 NE SUNSET BLVD 509643858
P152744818 2832 NE SUNSET BLVD 509643589
P152744819 2842 NE SUNSET BLVD 509643890
P152744820 2848 NE SUNSET BLVD, LIGHT 509643891
X144390502 2830 NE SUNSET BLVD, B 509643943 3000820114
H099364987 2830 NE SUNSET BLVD, A 509643944
Z010192007 1171 KIRKLAND AVE NE 509643945 3000820207
Z008099949 2808 NE SUNSET BLVD 509643946 3000819858
Z064422293 2808 NE SUNSET BLVD 509643948
P149157899 2812 NE SUNSET BLVD 509643949 3000820116
P149157370 2810 NE SUNSET BLVD, 1281 509643990
Z002780812 2816 NE SUNSET BLVD 509643991
P152745369 2806 NE SUNSET BLVD,B2 509643992 3000820210
P152745371 2806 NE SUNSET BLVD,C-D 509643994
P152745370 2806 NE SUNSET BLVD,E-F-G 509644241
X150928706 2806 NE SUNSET BLVD, B 509644242
X149150576 2806 NE SUNSET BLVD, A 509644245
X149150575 2806 NE SUNSET BLVD, HSE 509644247
P05 TO M10
-REMOVE OH SVC, ± 50', ACTUAL____'
P06 TO H04
-REMOVE OH TO UG SEC, ± 50', ACTUAL____'
P06 TO M12
-REMOVE OH SVC, ± 50', ACTUAL____'
P07 TO M13
-REMOVE OH SVC, ± 30', ACTUAL____'
P08 TO M14
-REMOVE OH SVC, ± 30', ACTUAL____'
RESTORATION PER CITY OF RENTON STANDARDS
This permit is for Major construction work in the ROW and will be billed at an additional
$60/HR for inspections. After hours and weekend work will be billed at $125/HR
MFP20004566
108121843UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
Dave Honeysett 253-245-0883 9/21/20
Jessica Reibman 425-457-4004 9/21/20
N/A N/A N/A
Jessica Reibman 425-457-4004 9/21/20
RW#RENTON
SOLERA - SERVIC WRECK OUT
POLES REMOVAL, REMOVE OH SVCS & METERS
2832 SUNSET LN NE, RENTON, WA 98056
N/A N/A
N/A 108121843
AS NOTED 2/2
KING N/A N/A CSPSKEPM
NW 9-23N-05E N/A N/A
2305E034 2305E040 2305E034 PRE-11
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
OVERHEAD CIRCUIT MAP
SCALE: 6" = 1 MILE
POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
SITE
#
POLE DATA POLE
TEL TV FIBER TRAN RMVD ID NUMBER
GRID #HEIGHT CLASS YEAR TOPPED RMVD
P01 318558-166709 45 3 2017
P02 318557-166713 40 2 1958
P03 318567-166713 40 2 1958
P04 318582-166731 40 3 1958
P05 318598-166743 45 4 1961
P06 318607-166743 45 3 1960
P07 318616-166751 45 2 1961
P09 318608-166723 45 4 1965
P10 318596-166715 40 1 1965
WIRE REMOVAL TABLE
Location
Wire Size & Type Quantity
Length
(per
conductor)RemarksFromTo
P01 P02 #4 CU -
PRIM/NEU XX XXX
P02 P03 #4 CU -
PRIM/NEU
P03 P04 #2 ACSR -
PRIM/NEU
P04 P05 #4 CU -
PRIM/NEU
P05 P06 #2 ACSR -
PRIM/NEU
P06 P07 #4 ACSR -
PRIM/NEU
P07 P08 SPAN GUY
P06 P08 #2 ACSR -
PRIM/NEU
P08 P09 #2 ACSR -
PRIM/NEU
P09 P10 #2 ACSR -
PRIM/NEU
P10 P11 SPAN GUY/OH
SEC
Total Feet (Wire Size & Type) Removed
Removed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P02
318557-166713
3 X 25kVA 120/208v
Removed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P03
318567-166713
3 X 100kVA 120/208v
Removed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P05
318598-166743
3 X 25kVA 120/208v
Removed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P07
318616-166751
3 X 50kVA 120/208v
Removed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P09
318608-166723
3 X 37.5kVA 120/208v
Removed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P10
318557-166713
3 X 25kVA 120/208V
JOB SITE
MFP20004566
MFP20004566