HomeMy WebLinkAboutP_Reply #1_SIte Bldg 05-070_ location on site_200918_v3.pdfPERMIT SET
RENTON SITE
COMPOSITE CIVIL SITE PLAN
C6 C4
GALVANIZATION NOTE
20' WIDE
FIRE-LANE CODE
REQUIREMENT
20' WIDE
FIRE-LANE CODE
REQUIREMENT
15' LANDSCAPING
BUFFER TO
PROPERTY LINE
Code-Required Minimum Setbacks:
15' from North 6th Street, to North
20' from Logan Avenue North, to East
80' from Renton Stadium Property, to South
15' Frontage Landscape
20' Fire Department Access around bldg
20' SETBACK TO
LOGAN AVE N.
PAINT HANGAR FOOTPRINT HAS BEEN
OPTIMIZED TO MEET REQUIRED SETBACKS
Building 05-70 is situated on the
property, as far west and as far
south as possible, to meet the
minimum fire-lane requirements
from the existing fire station
building 05-028.
Stall and Tow Path Area
requirements precludes Building
05-070 from shifting north.
The footprint size of Building
5-70 has been optimized to meet
the setback requirements to the
east.
It is not viable to shift the building
further west, without falling out of
compliance with the Fire Code.
Response to City Comment #1 of 04/22/20
KPFF, 2020-05-13