Loading...
HomeMy WebLinkAboutW-382404w Q z U w w 0 N U rr- 11 W 75 CU 11 rr- J J z 0 z Lu rr- -----------JONESAVES------ • ONE- CA L L REFERENCE �ON Y LITIES ACONTRACTOR RE SHOWN OR ®ALL FIELD LOCATE ALL EXISTING 800- 424- 55 PRIIORETOA MINIMUM F 72 HOURS Know what's below. call before you dig. ORIGINAL PUNS STAMPED BY: ANDREW WEYGANDT ON:B/19/17 I —T J BM—L I RENTON A VE S ——T,— ---- ,--r— �N-mmmmm- 0 120 240 1 "=120' iw�2 � I L—I L-L--i-11 1—Lim J L_ Y M-.-eW CEDAR A VE S 'Ile / HORIZONTAL DATUM — NAD 1983/91 POSITIONS FOR COORDINATES ARE BASED ON WIGS DATA POINT NUMBER RENT418, BRASS PIN SET IN TOP OF A CONCRETE MONUMENT AT THE INTERSECTION OF S 7TH ST AND RENTON AVE S. NORTH: 175877.4200 EAST. 1302310.3249 AND WGS DATA POINT RENT415, 4" CONCRETE MONUMENT IN CASE WITH 1" BRASS DISK SCRIBED "X", SET 0.6' BELOW GRADE, AT THE INTERSECTION OF SW 7TH STREET AND JONES AVE S. NORTH: 175877.1700 EAST. 1303337.4700 ELEVATIONS ARE BASED ON CITY OF RENTON CONTROL POINT NUMBER RENT418, BRASS PIN SET IN TOP OF A CONCRETE MONUMENT AT THE INTERSECTION OF S 7TH ST AND RENTON AVE S. ELEVATION = 305.786 FEET ELEVATIONS VERIFIED BY CITY OF RENTON CONTROL POINT RENT784, BRASS PLUG IN CONCRETE MONUMENT CASE, SET 0.1' BELOW GRADE, AT THE INTERSECTION OF SE 19TH ST AND PUGET DRIVE SE. ELEVATION = 417.33 FEET SURVEYED: SCALE: BRH DESIGNED AW DRAWN: AW ONE INCH CHECKED: AT FULL SCALE AW, AG IF NOT ONE INCH NO. REVISION BY DATE APPR APPROVEDSCALE ACCORDINGLY AG BENCHMARK "A" TOP CENTER BOLT OF FIRE HYDRANT AT THE SOUTHEAST CORNER OF S 7TH ST AND GRANT AVE S ELEVATION=341.68' BENCHMARK "D" NORTHERLY TOP BOLT OF FIRE HYDRANT AT THE NORTHWEST CORNER OF S 9TH ST AND JONES AVE S ELEVATION=383.89' BENCHMARK "G" SOUTHERLY MOST BONNET BOLT OF FIRE HYDRANT AT THE NORTHEAST CORNER OF S 9TH AVE AND RENTON AVE S ELEVATION=306.63' BENCHMARK "M" SET CHISELED 'Er ON SOUTHWEST CORNER OF WATER VAULT AND NORTHEAST CORNER OF RENTON AVE S AND BEACON WAY S ELEVATION=226.34' BENCHMARK "P" TOP CENTER BOLT OF FIRE HYDRANT AT THE SOUTHEAST CORNER OF GRANT AVE S AND S 1OTH ST ELEVA1I0N=332.99' BENCHMARK "V" TOP CENTER BOLT OF FIRE HYDRANT AT THE EASTERLY SIDE OF S 5TH ST AND CEDAR AVE S ELEVA1I0N=196.62' VERTICAL: NAVD 1988 HORIZONTAL: HAD 1983/1991 DATUM BENCHMARK "B" NORTHERLY TOP BOLT OF FIRE HYDRANT AT THE SOUTHEAST CORNER OF S 7TH ST AND HIGH AVE S ELEVA1I0N=365.71' BENCHMARK "E" NORTHERLY TOP BOLT OF FIRE HYDRANT AT SOUTHEAST CORNER OF S 9TH ST AND HIGH AVE S ELEVATION=366.44' BENCHMARK "J" TOP CENTER BOLT OF FIRE HYDRANT AT SOUTHEAST END OF HIGH AVE S ELEVA1I0N=367.50' BENCHMARK "N" TOP CENTER BOLT OF FIRE HYDRANT ON THE WEST SIDE OF RENTON AVE S IN FRONT OF 329 RENTON AVE S ELEVA1I0N=170.30' BENCHMARK "Q" NORTH RIM OF SEWER MANHOLE AT THE SOUTHEAST CORNER OF RENTON AVE S AND S 10TH ST ELEVA1I0N=289.40' BENCHMARK "T" TOP CENTER BOLT OF FIRE HYDRANT AT THE EAST SIDE AT THE SOUTH END OF CEDAR AVE S ELEVA1I0N=231.54' BENCHMARK "W" TOP CENTER BOLT OF FIRE HYDRANT AT THE EASTERLY SIDE OF S 4TH ST AND CEDAR AVE S ELEVA1I0N=140.77' BENCHMARK "C" NORTHERLY TOP BOLT OF FIRE HYDRANT AT THE SOUTHWEST CORNER OF S 7TH ST AND JONES AVE S ELEVA1I0N=375.30' BENCHMARK "F" TOP CENTER BOLT OF FIRE HYDRANT AT THE NORTHWEST CORNER OF S 9TH AVE AND GRANT AVE S ELEVA1I0N=349.39' BENCHMARK IV TOP CENTER BOLT OF FIRE HYDRANT AT THE SOUTHEAST END OF JONES AVE S ELEVA1I0N=395.56' BENCHMARK "0" TOP/SOUTHEASTERLY BOLT FOR METAL RAILING ON WEST SIDE OF RENTON AVE S ACROSS FROM 310 RENTON AVE S ELEVA1I0N=132.57' BENCHMARK "R" TOP CENTER BOLT OF FIRE HYDRANT AT THE SOUTHEAST CORNER OF GRANT AVE S AND BEACON WAY S ELEVATION=331.03' BENCHMARK "U" SOUTHWESTERLY BASE BOLT ON A CONIC LIGHT POLE AT THE EASTERLY SIDE OF S 6TH ST AND CEDAR AVE S ELEVA1I0N=223.32' CITY O� RENTON HILL UTILITY REPLACEMENT PROJECT 06/19/17 EIELDaoDK RENTON WATER KEY MAP DRAWING NO Planning/Building/Public Works Dept. AND G-3 HORIZONTAL CONTROL PLAN SHEET 4 OF:88 lVd-101318 1214