HomeMy WebLinkAboutW-382404w
Q
z
U
w
w
0
N
U
rr-
11
W
75
CU
11
rr-
J
J
z
0
z
Lu
rr-
-----------JONESAVES------
•
ONE- CA L L REFERENCE �ON Y LITIES ACONTRACTOR RE SHOWN OR
®ALL FIELD LOCATE ALL EXISTING
800- 424- 55 PRIIORETOA MINIMUM
F 72 HOURS
Know what's below.
call before you dig.
ORIGINAL PUNS STAMPED BY:
ANDREW WEYGANDT ON:B/19/17
I
—T J
BM—L
I
RENTON A VE S
——T,— ---- ,--r—
�N-mmmmm-
0 120 240
1 "=120'
iw�2
� I
L—I L-L--i-11 1—Lim J L_
Y M-.-eW
CEDAR A VE S 'Ile
/
HORIZONTAL DATUM — NAD 1983/91
POSITIONS FOR COORDINATES ARE BASED ON WIGS DATA POINT NUMBER
RENT418, BRASS PIN SET IN TOP OF A CONCRETE MONUMENT AT THE
INTERSECTION OF S 7TH ST AND RENTON AVE S.
NORTH: 175877.4200 EAST. 1302310.3249
AND WGS DATA POINT RENT415, 4" CONCRETE MONUMENT IN CASE WITH 1"
BRASS DISK SCRIBED "X", SET 0.6' BELOW GRADE, AT THE INTERSECTION OF
SW 7TH STREET AND JONES AVE S.
NORTH: 175877.1700 EAST. 1303337.4700
ELEVATIONS ARE BASED ON CITY OF RENTON CONTROL POINT NUMBER
RENT418, BRASS PIN SET IN TOP OF A CONCRETE MONUMENT AT THE
INTERSECTION OF S 7TH ST AND RENTON AVE S.
ELEVATION = 305.786 FEET
ELEVATIONS VERIFIED BY CITY OF RENTON CONTROL POINT RENT784, BRASS
PLUG IN CONCRETE MONUMENT CASE, SET 0.1' BELOW GRADE, AT THE
INTERSECTION OF SE 19TH ST AND PUGET DRIVE SE.
ELEVATION = 417.33 FEET
SURVEYED: SCALE:
BRH
DESIGNED
AW
DRAWN:
AW
ONE
INCH
CHECKED: AT FULL SCALE
AW, AG IF NOT ONE INCH
NO. REVISION BY DATE APPR APPROVEDSCALE ACCORDINGLY
AG
BENCHMARK "A"
TOP CENTER BOLT OF FIRE
HYDRANT AT THE SOUTHEAST
CORNER OF S 7TH ST AND GRANT
AVE S
ELEVATION=341.68'
BENCHMARK "D"
NORTHERLY TOP BOLT OF FIRE
HYDRANT AT THE NORTHWEST
CORNER OF S 9TH ST AND JONES
AVE S
ELEVATION=383.89'
BENCHMARK "G"
SOUTHERLY MOST BONNET BOLT
OF FIRE HYDRANT AT THE
NORTHEAST CORNER OF S 9TH
AVE AND RENTON AVE S
ELEVATION=306.63'
BENCHMARK "M"
SET CHISELED 'Er ON SOUTHWEST
CORNER OF WATER VAULT AND
NORTHEAST CORNER OF RENTON
AVE S AND BEACON WAY S
ELEVATION=226.34'
BENCHMARK "P"
TOP CENTER BOLT OF FIRE
HYDRANT AT THE SOUTHEAST
CORNER OF GRANT AVE S AND S
1OTH ST
ELEVA1I0N=332.99'
BENCHMARK "V"
TOP CENTER BOLT OF FIRE
HYDRANT AT THE EASTERLY SIDE
OF S 5TH ST AND CEDAR AVE S
ELEVA1I0N=196.62'
VERTICAL: NAVD 1988
HORIZONTAL: HAD 1983/1991
DATUM
BENCHMARK "B"
NORTHERLY TOP BOLT OF FIRE
HYDRANT AT THE SOUTHEAST
CORNER OF S 7TH ST AND HIGH
AVE S
ELEVA1I0N=365.71'
BENCHMARK "E"
NORTHERLY TOP BOLT OF FIRE
HYDRANT AT SOUTHEAST CORNER
OF S 9TH ST AND HIGH AVE S
ELEVATION=366.44'
BENCHMARK "J"
TOP CENTER BOLT OF FIRE
HYDRANT AT SOUTHEAST END OF
HIGH AVE S
ELEVA1I0N=367.50'
BENCHMARK "N"
TOP CENTER BOLT OF FIRE
HYDRANT ON THE WEST SIDE OF
RENTON AVE S IN FRONT OF 329
RENTON AVE S
ELEVA1I0N=170.30'
BENCHMARK "Q"
NORTH RIM OF SEWER MANHOLE AT
THE SOUTHEAST CORNER OF
RENTON AVE S AND S 10TH ST
ELEVA1I0N=289.40'
BENCHMARK "T"
TOP CENTER BOLT OF FIRE
HYDRANT AT THE EAST SIDE AT
THE SOUTH END OF CEDAR AVE S
ELEVA1I0N=231.54'
BENCHMARK "W"
TOP CENTER BOLT OF FIRE
HYDRANT AT THE EASTERLY SIDE
OF S 4TH ST AND CEDAR AVE S
ELEVA1I0N=140.77'
BENCHMARK "C"
NORTHERLY TOP BOLT OF FIRE
HYDRANT AT THE SOUTHWEST
CORNER OF S 7TH ST AND JONES
AVE S
ELEVA1I0N=375.30'
BENCHMARK "F"
TOP CENTER BOLT OF FIRE
HYDRANT AT THE NORTHWEST
CORNER OF S 9TH AVE AND GRANT
AVE S
ELEVA1I0N=349.39'
BENCHMARK IV
TOP CENTER BOLT OF FIRE
HYDRANT AT THE SOUTHEAST END
OF JONES AVE S
ELEVA1I0N=395.56'
BENCHMARK "0"
TOP/SOUTHEASTERLY BOLT FOR
METAL RAILING ON WEST SIDE OF
RENTON AVE S ACROSS FROM 310
RENTON AVE S
ELEVA1I0N=132.57'
BENCHMARK "R"
TOP CENTER BOLT OF FIRE
HYDRANT AT THE SOUTHEAST
CORNER OF GRANT AVE S AND
BEACON WAY S
ELEVATION=331.03'
BENCHMARK "U"
SOUTHWESTERLY BASE BOLT ON A
CONIC LIGHT POLE AT THE
EASTERLY SIDE OF S 6TH ST AND
CEDAR AVE S
ELEVA1I0N=223.32'
CITY O� RENTON HILL UTILITY REPLACEMENT PROJECT 06/19/17
EIELDaoDK
RENTON
WATER KEY MAP DRAWING NO
Planning/Building/Public Works Dept. AND G-3
HORIZONTAL CONTROL PLAN SHEET 4 OF:88
lVd-101318 1214