HomeMy WebLinkAboutW-382428N 7 10+24.9, 14.5LT 1 STA '^",vTz-A 9-.8'Li RENTON AVE S INSTALL: 1 - 8'x8" TEE (M.fxAW/ CONC. THRUST BLOCK 2- 8GV (MJxM✓) FLxFL FL 10+24, 2.7LT 2 STA ; 0 r24 f2.I'LRENTON AVE S. INSTALL: 1 - 87x8" TEE OAkW) W/ CONC. THRUST BLOCK 1- 80GV &JxM✓) 1 - 8' SfF6OL OSTA 10+06.4, 3.7'RT RENTON AVE S INSTALL: 1 - 8' 45' BEND (M✓XM✓) W/ CONC. THRUST BLOCK 1 - 8' CAP (M✓) 2' -BLOW OFF- ASSEMBLY TEMPORARY 7HRUST BLOCK -, --- I 4 STA 1 +2 .4, 7.2RT '�'� �'�,�RT RENTON AVE S. INSTALL: 1 - 87x8" TEE (MJXFL) W/ CONC. THRUST BLOCK 1 - 8'GV (FLxM✓) 2 - 8' CAP (M✓) 1 n" VER77CA/ GROSS ROI vR/G STA 7MW PER STl DETAIL 300.6 1 - CONC. THRUST BLOCK OSTA 10+37.6, 7.0'RT RENTON AVE S INSTALL: I- CONCRETE DEADMAN THRUST BLOCK SHACKLE DEADMAN BLOCK TO EXISTING 6"x8' TEE OSTA 10+06.4, 3.7'RT RENTON AVE S CONNECT TO EX. 8" D/ WATER. INSTALL: 1 - 8' 45' BEND (M✓xM✓) W/ CONC. THRUST BLOCK 2- 8' SPOOL 2- 8' SLEEVE 1 - SHACKLE RODS OSTA '^?z,� -o3oT V RENTON AVE S CONNECT TO EX. 8" DI WATER. SHACKLE DEAD MAN BLOCK TO NEW 8" TEE. INSTALL: 1 - 8' SPOOL 1 - 8' SLEEVE INSTALL 1C1 , G 100 A W#A C900 IN PLACE GC EX4STIAIG 10- IA/1R SEKI W/ FLEXIBLE XIB E FERMCO COUPLINGS IF NECESSARY DUE TO LIMITED PIPE CLEARANCE W7H -E IS71NGCGtlTRA4"9 ROT7 1AL DAMAGE DUE T�GILINE CONSMUCTIOM O ABANDON GATE VALVE. CLOSE VALVE AND REMOVE VALVE BOX. CAP AND BLOCK VALVE. AMERICAN SURVEYING & ENVIRONMENTAL, LLC (ASE) CONDUCTED AN AS -BUILT SURVEY TO LOCATE ALL WATER VALVES AND HYDRANTS. AS -BUILT DRAWING REDLINE MARKUPS WERE MAINTAINED BY LASER UNDERGROUND & EARTHWORKS, INC. BY THE ON -SITE CONSTRUCTION FOREMAN AND PROVIDED TO AGE TO PREPARE THE FINAL RECORD DRAWINGS. THE RECORD DRAWINGS REFLECT THE AS -CONSTRUCTED CONDITIONS BASED ON A COMBINATION OF FIELD SURVEY DATA AND THE AS -BUILT REDLINE MARKUP DRAWINGS PROVIDED BY LASER UNDERGROUND & EARTHWORKS, INC. AND SHOULD BE FIELD VERIFIED FOR ANY FUTURE USE. ALL WATER VALVES AND HYDRANTS WERE FIELD SURVEYED IN THEIR AS -BUILT LOCATIONS AND ACCURATELY REFLECTED HEREON. �_I 0� z PROPOSED SANITARY SEWER. SEE SHEET S-4. � L � ° FFY 24"CED RENTON AVE S. 0 3 c� N C w w of Co cn o GAS _ W D r W �_I 0-) z PROPOSED SANITARY SEWER. SEE SHEET S-4. / L � �-\ 24"CED RENTON AVE S. EX. 6" C1 (TO BE ABAND TESTING DETAIL -LI �E II D 6 fN w w of S AS GAS _ N r W ° o° + ° O 01 N FINAL CONNECTION DETAIL CONNECTION DETAIL relmo ONE— CA L L REFERENCEING UTILITIES ARE ONLY. CO THRACTOR OR ALL MELD LOCATE ALL EXISTING 800— 424— 55 JWILITIES TOCONSTRUCTION.0 72 HOURS now what's below. call before you dig. STA. 10+23 RENTON AVE S SCALE: 1 "=10' N... 2 o ° z CX m U) 1 STA. 0+07-+3'_+LT S 77H S7REET N + INSERT POLYPIG AND INSTALL: 1 - 8' CAP (M✓) W/ 2" BLOW=OFF ° a AND TEMPORARY THRUST U ° BLOCKING ° a N a� 2 a a AS GAS - S AS GAS - T— O ° c� a 4 a N DJ A W q g a S1 PROPOSED STORM WATER. SEE SHEET SW-2. o o� Z o 0 0 c Q n u C n AL v a ° PROPOSED STORM WATER. SEE SHEET SW-2. II I I NORTH .,LVIJIUN 111J 1 1LL. 1 - 8" TEE (FLxFL) 2 - 8"GV (FLxMJ) 1 - 8" BLIND FLANGE 1 - 8" SPOOL 2 - CONC. 714RUST BLOCK 1 - TEMPORARY THRUST BLOCK 1 0 (a E8 2 + EVJ ~ S a TESTING DETAIL TESTING DETAIL REMOVE POLYPIG LAUNCH STA71ON AND INSTALL: 1 - 8' SPOOL 1 - 8' SLEEVE CUT & CAP 1 - 8' 22Y2' BEND (M✓XM✓) W/ EX. 40W — — CONC. THRUST BLOCK (n W >,. U1 O Q. w1'a IC\ — J c� a° N PROP, Bw DI S. 7L"D N S. 7TH STREET _0 EX. 6" DI (TO D) U (TO BE ABANDONED) CUT & CAP EX. 60W If EX. 10 SS 111 EX. 10 SS PROPOSED STORM WATER. a q N C 2 SEE SHEET SW-1. �u STA. 6+30.6 8.51T CEDAR AVE S — Z REMOVE EX. 8'x6" REDUCER AND 8° 'o Z SPOOL. CONNCET TO EX. 80GV. k m INSTALL: S40 / 1 - 80 SPOOL a 4 I —8�LEE ro 1 - 8' 22%2' BEND (M✓xM✓) W/ PROPOSED S CONC. THRUST BLOCK STORM WATER. SEE SHEET SII SHACKLE FROM EX. 120x8" TEE TO fly Y I 11 /// NEW 8' 22 Yi BEND FINAL CONNECTION DETAIL CONNECTION DETAIL STA. 6+37 CEDAR AVE S SCALE: 1 "=10' NORTH / REMOVED EXISTING 6" GAS VALVE; Ile STA. 22+49.8 9.21T RENTON AVE S STA. 22+55.8 9.21T RENTON AVE CONNECT TO EX. 6"x6' TEE INSTALL: 1 - 8' 90' BEND (FLxFL) W/ CONC. THRUST BLOCK 2 - 8"X6' REDUCER (M✓XM✓) / 2 - 8" SPOOL w 2 - 6 SPOOL / 1 - 8" SLEEVE 1 - 6" SLEEVE / TS SHACKLE BEND TO TEE Go � o ° ° bw 6 DI VU S Q EX. 8" SS N � = G 2 CUT & CAP EX. 60W G24 RENTON AVE S. sbi7 \ PROP. 8' Dl °22+61.7, 3.6�RT FINAL CONNECTION DETAIL CONNECTION DETAIL STA 22+56 RENTON AVE S SCALE: 1 "=10' NORTH NOTE. • ALL PIPE SHALL BE BAGGED AND SEALED FROM POINT OF DELIVERY 714ROUGH INSTALLATION. SURVEYED: SCALE: DAIS: BRH VERTICAL: NAVD 83/1 RENTON HILL UTILITY REPLACEMENT PROJECT 6/ / HORIZONTAL: NAD 191988 1 Q6 19 17 DESIGNED: 1 "— 10 �� rt C 1 T Y OF FIEL0900K: AW DRAWN: RENTON AW CONNECTION DETAILS PAGE: II— ONE INCH II DATUM DRAWING N0: CHECKED: AT FUI LL S LE l Planning/Building/Public Works Dept. W-21 AG IF NOT ONE INCH BY DATE APPR APPROVEOA:G SOALE ACCORDINGLY SHEET: nn OR 88 IWI-101318121